Small medical gas cylinders — Pin-index yoke-type valve connections

ISO 407:2004 concerns pin-index yoke-type valve connections for small medical gas cylinders, with a maximum working pressure (filling pressure at 15 °C) of 200 bar. This type of connection is typically used for small cylinders (5 l or below). In some cases, it may be used for larger cylinders. In this latter case, consideration shall be given to the need for valve protection. It specifies: basic dimensions; requirements for alternative designs of the yoke-type valve connections; dimensions and positions for the holes and pins for the outlet connections. It also specifies the dimensions and positions for the holes and pins for the outlet connections for certain gases and gas mixtures. ISO 407:2004 applies to small medical gas cylinders used for patient care, including therapeutic, diagnostic and prophylactic applications, in hospitals and for emergency treatment.

Petites bouteilles à gaz médicaux — Raccords de robinets du type à étrier avec ergots de sécurité

L'ISO 407:2004 traite des raccords de robinets du type à étrier avec ergots de sécurité, destinés aux petites bouteilles à gaz médicaux ayant une pression maximale de travail (pression de remplissage à 15 °C) de 200 bar. Ce type de raccord est essentiellement utilisé pour les petites bouteilles (de 5 l ou moins). Parfois, il peut être utilisé pour des bouteilles plus grandes. Dans ce cas, l'attention doit être portée sur la nécessité d'une protection du robinet. Elle spécifie les dimensions de base des raccords, les exigences requises des variantes de construction des raccords de robinets du type à étrier, et les dimensions et positions des trous et des ergots des sorties de raccords. Elle spécifie également les dimensions et les positions des trous et des ergots des sorties de raccords pour les gaz et les mélanges de gaz donnés dans le Tableau 1. L'ISO 407:2004 est applicable aux petites bouteilles à gaz médicaux utilisées pour des soins aux malades, comportant des applications thérapeutiques, diagnostiques et prophylactiques, dans les hôpitaux et pour les traitements d'urgence.

General Information

Status
Withdrawn
Publication Date
07-Nov-2004
Withdrawal Date
07-Nov-2004
Current Stage
9599 - Withdrawal of International Standard
Completion Date
04-Jun-2021
Ref Project

Relations

Effective Date
28-Feb-2023

Buy Standard

Standard
ISO 407:2004 - Small medical gas cylinders -- Pin-index yoke-type valve connections
English language
24 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 407:2004 - Petites bouteilles a gaz médicaux -- Raccords de robinets du type a étrier avec ergots de sécurité
French language
24 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

INTERNATIONAL ISO
STANDARD 407
Third edition
2004-11-01


Small medical gas cylinders — Pin-index
yoke-type valve connections
Petites bouteilles à gaz médicaux — Raccords de robinets du type à
étrier avec ergots de sécurité




Reference number
ISO 407:2004(E)
©
ISO 2004

---------------------- Page: 1 ----------------------
ISO 407:2004(E)
PDF disclaimer
This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but
shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In
downloading this file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat
accepts no liability in this area.
Adobe is a trademark of Adobe Systems Incorporated.
Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation
parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In
the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below.


©  ISO 2004
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or
ISO's member body in the country of the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland

ii © ISO 2004 – All rights reserved

---------------------- Page: 2 ----------------------
ISO 407:2004(E)
Contents Page
Foreword. iv
1 Scope. 1
2 Normative references . 1
3 Valve. 1
4 Yoke. 2
5 Basic dimensions. 2
5.1 General. 2
5.2 Pin-index yoke-type valve body . 3
5.3 Single-pin yoke-type valve connection system . 4
5.4 Two-pin yoke-type valve connection system with the pins in a single row . 4
5.5 Two-pin yoke-type valve connection system with the pins in a double row . 5
5.6 Basic dimensions. 5
6 Requirements for alternative designs of yoke-type valve connections. 6
6.1 Requirements for the design of the connecting yoke. 6
6.2 Examples of alternative construction for the connecting yoke . 7
7 Dimensions and positions of the holes and pins for yoke-type valve connections. 9
7.1 General. 9
7.2 Outlet connection with single-pin system. 9
7.3 Outlet connections with two-pin/single-row system. 10
7.4 Outlet connection with two-pin/double-row system . 20

© ISO 2004 – All rights reserved iii

---------------------- Page: 3 ----------------------
ISO 407:2004(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the
International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 407 was prepared by Technical Committee ISO/TC 58, Gas cylinders, Subcommittee SC 2, Cylinder
fittings.
This third edition cancels and replaces the second edition (ISO 407:1991), which has been technically revised.

iv © ISO 2004 – All rights reserved

---------------------- Page: 4 ----------------------
INTERNATIONAL STANDARD ISO 407:2004(E)

Small medical gas cylinders — Pin-index yoke-type valve
connections
1 Scope
This International Standard concerns pin-index yoke-type valve connections for small medical gas cylinders,
with a maximum working pressure (filling pressure at 15 °C) of 200 bar. This type of connection is typically
used for small cylinders (5 l or below). In some cases, it may be used for larger cylinders. In this latter case,
consideration shall be given to the need for valve protection.
It specifies:
 basic dimensions;
 requirements for alternative designs of the yoke-type valve connections;
 dimensions and positions for the holes and pins for the outlet connections.
It also specifies the dimensions and positions for the holes and pins for the outlet connections for the gases
and gas mixtures given in Table 1.
This International Standard applies to small medical gas cylinders used for patient care, including therapeutic,
diagnostic and prophylactic applications, in hospitals and for emergency treatment.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
ISO 32:1977, Gas cylinders for medical use — Marking for identification of content
3 Valve
Each small medical gas cylinder can be fitted with a yoke valve (see Clause 5). The yoke valve shall have
location holes of the dimensions and in the positions indicated in Clause 7 for the appropriate gas or gas
mixture.
The name or chemical symbol of the gas or gas mixture shall be clearly and indelibly stamped on the valve.
© ISO 2004 – All rights reserved 1

---------------------- Page: 5 ----------------------
ISO 407:2004(E)
Table 1 — Allocated gases and gas mixtures
Chemical
Gas or gas mixture
symbol
Oxygen O
2
Oxygen/carbon dioxide (CO u 7 %) O + CO ,
2 2 2
Oxygen/helium (He u 80 %) O + He
2
Ethylene C H
2 4
Nitrous oxide (with and without draw-off) N O
2
Cyclopropane C H
3 6
Helium and helium/oxygen (O < 20 %) He
2
Carbon dioxide (with and without draw-off) and carbon dioxide/oxygen CO > 7 %) CO
2 2
Medical air Air
Nominal mixture 50 % oxygen/50 % nitrous oxide (47,5 % < N O < 52,5 %) O + N O
2 2 2
Nitrogen N
2
Mixture of air, helium and carbon monoxide (CO < 1 %) Air + He + CO

4 Yoke
The connecting yoke shall conform to the requirements and dimensions given in Clauses 5 and 6. The yoke
shall be fitted with pins, the dimensions and the positions of which correspond to the holes in the valve as
indicated in Clause 7 for the appropriate gas or gas mixture.
The name or chemical symbol of the gas or gas mixture shall be clearly and indelibly stamped on the yoke. If
an identification colour is used, it shall be in conformity with ISO 32.
Examples of the alternative designs for the connecting yoke are given in 6.2.
In Figures 3 and 4, the circled numbers and letters are the pin-hole positions.
5 Basic dimensions
5.1 General
The basic dimensions for pin-index yoke-type valve connections are shown in Figures 1 to 4, and are listed in
Table 2.
2 © ISO 2004 – All rights reserved

---------------------- Page: 6 ----------------------
ISO 407:2004(E)
5.2 Pin-index yoke-type valve body
Dimensions in millimetres

a
Applicable only to single-key valves.
Figure 1 — Pin-index yoke-type valve body
© ISO 2004 – All rights reserved 3

---------------------- Page: 7 ----------------------
ISO 407:2004(E)
5.3 Single-pin yoke-type valve connection system

Figure 2 — Single-pin yoke-type valve connection system

5.4 Two-pin yoke-type valve connection system with the pins
...

NORME ISO
INTERNATIONALE 407
Troisième édition
2004-11-01


Petites bouteilles à gaz médicaux —
Raccords de robinets du type à étrier
avec ergots de sécurité
Small medical gas cylinders — Pin-index yoke-type valve connections




Numéro de référence
ISO 407:2004(F)
©
ISO 2004

---------------------- Page: 1 ----------------------
ISO 407:2004(F)
PDF – Exonération de responsabilité
Le présent fichier PDF peut contenir des polices de caractères intégrées. Conformément aux conditions de licence d'Adobe, ce fichier
peut être imprimé ou visualisé, mais ne doit pas être modifié à moins que l'ordinateur employé à cet effet ne bénéficie d'une licence
autorisant l'utilisation de ces polices et que celles-ci y soient installées. Lors du téléchargement de ce fichier, les parties concernées
acceptent de fait la responsabilité de ne pas enfreindre les conditions de licence d'Adobe. Le Secrétariat central de l'ISO décline toute
responsabilité en la matière.
Adobe est une marque déposée d'Adobe Systems Incorporated.
Les détails relatifs aux produits logiciels utilisés pour la création du présent fichier PDF sont disponibles dans la rubrique General Info
du fichier; les paramètres de création PDF ont été optimisés pour l'impression. Toutes les mesures ont été prises pour garantir
l'exploitation de ce fichier par les comités membres de l'ISO. Dans le cas peu probable où surviendrait un problème d'utilisation,
veuillez en informer le Secrétariat central à l'adresse donnée ci-dessous.


©  ISO 2004
Droits de reproduction réservés. Sauf prescription différente, aucune partie de cette publication ne peut être reproduite ni utilisée sous
quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie et les microfilms, sans l'accord écrit
de l'ISO à l'adresse ci-après ou du comité membre de l'ISO dans le pays du demandeur.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax. + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Version française parue en 2005
Publié en Suisse

ii © ISO 2004 – Tous droits réservés

---------------------- Page: 2 ----------------------
ISO 407:2004(F)
Sommaire Page
Avant-propos. iv
1 Domaine d'application. 1
2 Références normatives. 1
3 Robinet. 1
4 Étrier. 2
5 Dimensions de base . 2
5.1 Généralités. 2
5.2 Corps de robinet du type à étrier avec ergot de sécurité . 3
5.3 Système de raccord de robinet du type à étrier avec un seul ergot de sécurité. 4
5.4 Système de raccord de robinet du type à étrier avec deux ergots de sécurité sur un seul
rang. 4
5.5 Système de raccord de robinet du type à étrier avec deux ergots de sécurité sur deux
rangs. 5
5.6 Dimensions de base . 5
6 Exigences pour variantes de construction de raccords de robinets du type à étrier . 6
6.1 Exigences de construction de l'étrier de fixation . 6
6.2 Exemples de variantes de construction pour l'étrier de fixation . 6
7 Dimensions et positions des trous et ergots pour raccords de robinets du type à étrier . 9
7.1 Généralités. 9
7.2 Raccord de sortie à système à un seul ergot.9
7.3 Sorties de raccord à système à deux ergots sur un seul rang . 10
7.4 Raccord de sortie à système à deux ergots sur deux rangs. 20

© ISO 2004 – Tous droits réservés iii

---------------------- Page: 3 ----------------------
ISO 407:2004(F)
Avant-propos
L'ISO (Organisation internationale de normalisation) est une fédération mondiale d'organismes nationaux de
normalisation (comités membres de l'ISO). L'élaboration des Normes internationales est en général confiée
aux comités techniques de l'ISO. Chaque comité membre intéressé par une étude a le droit de faire partie du
comité technique créé à cet effet. Les organisations internationales, gouvernementales et non
gouvernementales, en liaison avec l'ISO participent également aux travaux. L'ISO collabore étroitement avec
la Commission électrotechnique internationale (CEI) en ce qui concerne la normalisation électrotechnique.
Les Normes internationales sont rédigées conformément aux règles données dans les Directives ISO/CEI,
Partie 2.
La tâche principale des comités techniques est d'élaborer les Normes internationales. Les projets de Normes
internationales adoptés par les comités techniques sont soumis aux comités membres pour vote. Leur
publication comme Normes internationales requiert l'approbation de 75 % au moins des comités membres
votants.
L'attention est appelée sur le fait que certains des éléments du présent document peuvent faire l'objet de
droits de propriété intellectuelle ou de droits analogues. L'ISO ne saurait être tenue pour responsable de ne
pas avoir identifié de tels droits de propriété et averti de leur existence.
L'ISO 407 a été élaborée par le comité technique ISO/TC 58, Bouteilles à gaz, sous-comité SC 2, Accessoires
de bouteilles.
Cette troisième édition annule et remplace la deuxième édition (ISO 407:1991), qui a fait l'objet d'une révision
technique.

iv © ISO 2004 – Tous droits réservés

---------------------- Page: 4 ----------------------
NORME INTERNATIONALE ISO 407:2004(F)

Petites bouteilles à gaz médicaux — Raccords de robinets du
type à étrier avec ergots de sécurité
1 Domaine d'application
La présente Norme Internationale traite des raccords de robinets du type à étrier avec ergots de sécurité,
destinés aux petites bouteilles à gaz médicaux ayant une pression maximale de travail (pression de
remplissage à 15 °C) de 200 bar. Ce type de raccord est essentiellement utilisé pour les petites bouteilles
(de 5 l ou moins). Parfois, il peut être utilisé pour des bouteilles plus grandes. Dans ce cas, l'attention doit être
portée sur la nécessité d'une protection du robinet.
Elle spécifie
 les dimensions de base des raccords,
 les exigences requises des variantes de construction des raccords de robinets du type à étrier, et
 les dimensions et positions des trous et des ergots des sorties de raccords.
Elle spécifie également les dimensions et les positions des trous et des ergots des sorties de raccords pour
les gaz et les mélanges de gaz donnés dans le Tableau 1.
La présente Norme internationale est applicable aux petites bouteilles à gaz médicaux utilisées pour des
soins aux malades, comportant des applications thérapeutiques, diagnostiques et prophylactiques, dans les
hôpitaux et pour les traitements d'urgence.
2 Références normatives
Les documents de référence suivants sont indispensables pour l'application du présent document. Pour les
références datées, seule l'édition citée s'applique. Pour les références non datées, la dernière édition du
document de référence s'applique (y compris les éventuels amendements).
ISO 32:1977, Bouteilles à gaz pour usages médicaux — Marquage pour l'identification du contenu
3 Robinet
Chaque petite bouteille à gaz médical peut être pourvue d'un robinet à étrier (voir Article 5). Le robinet à étrier
doit comporter des trous dont les dimensions et les positions sont indiquées dans l'Article 7 pour chaque gaz
ou mélange de gaz approprié.
Le nom ou le symbole chimique du gaz ou du mélange de gaz doit être marqué sur le robinet de façon lisible
et indélébile.
© ISO 2004 – Tous droits réservés 1

---------------------- Page: 5 ----------------------
ISO 407:2004(F)
Tableau 1 — Gaz et mélanges de gaz alloués
Gaz ou mélange de gaz Symbole
chimique
Oxygène O
2
Oxygène/dioxyde de carbone (CO u 7 %) O + CO
2 2 2
Oxygène/hélium (He u 80 %) O + He
2
Éthylène C H
2 4
Protoxyde d'azote (avec et sans soutirage) N O
2
Cyclopropane C H
3 6
Hélium et hélium/oxygène (O < 20 %) He
2
Dioxyde de carbone (avec et sans soutirage) et dioxyde de carbone/oxygène CO > 7 %) CO
2 2
Air médical Air
Mélange nominal de 50 % d'oxygène/50 % de protoxyde d'azote (47,5 % < N O < 52,5 %) O + N O
2 2 2
Azote N
2
Mélange d'air, d'hélium et de monoxyde de carbone (CO < 1 %) Air + He + CO
4 Étrier
L'étrier de fixation doit respecter les exigences et les dimensions données dans les Articles 5 et 6. L'étrier doit
être pourvu d'ergots dont les dimensions et les positions correspondent à celles des trous du robinet, comme
l'indique l'Article 7 pour chaque gaz ou mélange de gaz approprié.
Le nom ou le symbole chimique du gaz ou du mélange de gaz doit être marqué sur l'étrier de façon lisible et
indélébile. Si une couleur d'identification est appliquée, elle doit être en conformité avec l'ISO 32.
Des exemples de variantes pour la construction de l'étrier de fixation sont donnés en 6.2.
Aux Figures 3 et 4, les positions des trous d'ergots sont identifiées respectivement par des chiffres et des
lettres.
5 Dimensions de base
5.1 Généralités
Les dimensions de base des raccords de robinets du type à étrier avec ergots de sécurité sont indiquées aux
Figures 1 à 4 et énumérées dans le Tableau 2.
2 © ISO 2004 – Tous droits réservés

---------------------- Page: 6 ----------------------
ISO 407:2004(F)
5.2 Corps de robinet du type à étrier avec ergot de sécurité
Dimensions en millimètres

a
Applicable seulement aux robinets à une seule clé.
Figure 1 — Corps de robinet du type à étrier avec ergot de sécurité
© ISO 2004 – Tous droits réservés 3

---------------------- Page: 7 --
...

Questions, Comments and Discussion