SIST ETS 300 147 E2:2003
(Main)Transmission and Multiplexing (TM); Synchronous Digital Hierarchy (SDH); Multiplexing structure
- Abstract
Enhancements to the SDH interface standard (prETS 300 147) to cover refinement of overhead byte definitions, new payload mappings (such as ATM cells & DQDB slots), sub-STM-1 radio relay digital sections
- Status
- Published
- Publication Date
- 30-Nov-2003
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 01-Dec-2003
- Due Date
- 01-Dec-2003
- Completion Date
- 01-Dec-2003
SIST ETS 300 147 E2:2003 is the Slovenian version of ETS 300 147 Edition 2 from ETSI. It specifies the SDH multiplexing structure, the hierarchical bit rates, and the mapping schemes used in transmission networks based on Synchronous Digital Hierarchy (SDH). Engineers, network operators, buyers, and test teams use it to align how SDH signals, overhead, and payload mappings are structured for inter-vendor and inter-operator compatibility.
What does SIST ETS 300 147 E2:2003 specify?
SIST ETS 300 147 E2:2003 specifies the SDH hierarchy, the basic multiplexing structure, and the mapping schemes for transmission networks based on SDH. It organizes that material in Clauses 1 to 8 and one informative annex.
Clause 1 states the scope, Clauses 2 and 3 bring in references, definitions, and abbreviations, and Clauses 4 to 7 cover the bit rates, multiplexing structure, mapping, overhead bytes, and Section Overhead (SOH). Clause 8 covers conformance testing, and Annex A provides an informative bibliography.
What are the key requirements of SIST ETS 300 147 E2:2003?
SIST ETS 300 147 E2:2003 relies on ITU-T Recommendations G.707, G.708, and G.709 for the core SDH model, then adds the ETS-specific statements and status markings in Table 1. In practice, the document tells implementers which SDH functions are in scope for compliance and which parts are not relevant to this ETS.
- Clause 4 fixes the hierarchical bit rates according to G.707. That means SDH equipment has to follow the standard rate hierarchy rather than defining its own transport rates.
- Clause 5 defines the basic multiplexing structure shown in Figure 1 as a subset of G.709. This gives designers the signal chain from container through virtual container, tributary unit, administrative unit, and STM-N.
- Clause 6 and Table 1 set the multiplexing method and mapping, and mark each item as Normative (N) or Not Relevant (N/R). In practice, this tells vendors which G.709 functions matter when they are implemented and which are outside the ETS.
- Clause 6 covers Administrative Unit and Tributary Unit multiplexing, pointer processing, maintenance signals, timing recovery, Path Overhead (POH), and the CRC-7 polynomial algorithm. These are the mechanics that keep payloads aligned and traceable across SDH networks.
- Clause 6 also includes tributary mappings into VC-4, VC-3, VC-12, and VC-11, plus mapping of ATM cells. This matters because the standard is not limited to one traffic type and supports different transported signals.
- Clause 7 uses G.708 for the location and description of Section Overhead (SOH) bytes. That is the section-level framing and supervision information that equipment must interpret consistently.
- Clause 8 explains conformance testing at the functional-block level using SDH interface(s). This means compliance is checked by exercising specific network-element functions, not by treating the entire interface as one undivided feature.
- The standard also states that it is not an equipment specification. A function marked Normative must be implemented according to the requirement if that function is present.
What terms does SIST ETS 300 147 E2:2003 define?
SIST ETS 300 147 E2:2003 uses the following key abbreviations and terms:
- Asynchronous Transfer Mode (ATM) - a payload type that the standard maps into VC-4, VC-4-Xc, and other virtual containers.
- Administrative Unit Group (AUG) - the grouping used when multiplexing Administrative Units into STM-N.
- Section Overhead (SOH) - the bytes used for section-level control and supervision in SDH.
- Synchronous Transport Module-N (STM-N) - the SDH transport signal at hierarchy level N.
- Path Overhead (POH) - overhead associated with the virtual container path for end-to-end supervision.
- Tributary Unit-n (TU-n) - a lower-order SDH unit used in mapping tributary signals into higher-level containers.
- Virtual Container-n (VC-n) - the payload container that carries mapped traffic within SDH.
- Not Relevant (N/R) - a status used in Table 1 for items that are outside the scope of this ETS.
Who uses SIST ETS 300 147 E2:2003?
SIST ETS 300 147 E2:2003 is used by SDH equipment vendors, network operators, and inter-operator engineering teams. It is also relevant to conformance testers and quality or procurement staff who need to check which SDH mappings, overhead functions, and pointer behaviors a product supports.
What changed in SIST ETS 300 147 E2:2003 from the previous edition?
SIST ETS 300 147 E2:2003 is the second edition and it supersedes the first edition of ETS 300 147 from 1992. The scope states that it extends the SDH interface standard to refine overhead byte definitions, add new payload mappings such as ATM cells and DQDB slots, and cover sub-STM-1 radio relay digital sections.
Which standards are used with SIST ETS 300 147 E2:2003?
SIST ETS 300 147 E2:2003 uses three ITU-T Recommendations as its normative basis:
- ITU-T G.707 - provides the SDH bit rates used in Clause 4.
- ITU-T G.708 - provides the definitions used in Clause 3 and the SOH byte location and description used in Clause 7.
- ITU-T G.709 - provides the SDH multiplexing structure and mapping framework that Clause 5 and Clause 6 build on.
Annex A lists CCITT G.702, CCITT G.704, and CCITT G.811 as informative background references for hierarchy bit rates, frame structures, and timing requirements.
What does the SIST ETS 300 147 E2:2003 document contain?
SIST ETS 300 147 E2:2003 contains one figure for the SDH multiplexing structure and one main table that marks G.709 items as Normative or Not Relevant. It also includes pointer processing steps, mapping procedures, a CRC-7 polynomial algorithm, and conformance testing guidance for functional blocks inside a network element. Annex A provides a short bibliography for further technical context.
Get Certified
Connect with accredited certification bodies for this standard

ANCE
Mexican certification and testing association.

Intertek Slovenia
Intertek testing, inspection, and certification services in Slovenia.
LNE (Laboratoire National de Métrologie et d'Essais)
French national laboratory for metrology and testing.
Sponsored listings
Frequently Asked Questions
SIST ETS 300 147 E2:2003 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Transmission and Multiplexing (TM); Synchronous Digital Hierarchy (SDH); Multiplexing structure". This standard covers: Enhancements to the SDH interface standard (prETS 300 147) to cover refinement of overhead byte definitions, new payload mappings (such as ATM cells & DQDB slots), sub-STM-1 radio relay digital sections
Enhancements to the SDH interface standard (prETS 300 147) to cover refinement of overhead byte definitions, new payload mappings (such as ATM cells & DQDB slots), sub-STM-1 radio relay digital sections
SIST ETS 300 147 E2:2003 is classified under the following ICS (International Classification for Standards) categories: 33.040.20 - Transmission systems. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST ETS 300 147 E2:2003 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-december-2003
Prenos in multipleksiranje (TM) – Sinhrona digitalna hierarhija (SDH) – Struktura
multipleksiranja
Transmission and Multiplexing (TM); Synchronous Digital Hierarchy (SDH); Multiplexing
structure
Ta slovenski standard je istoveten z: ETS 300 147 Edition 2
ICS:
33.040.20 Prenosni sistem Transmission systems
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN ETS 300 147
TELECOMMUNICATION January 1995
STANDARD Second Edition
Source: ETSI TC-TM Reference: RE/TM-03013
ICS: 33.080
Transmission, multiplexing, SDH
Key words:
Transmission and Multiplexing (TM);
Synchronous Digital Hierarchy (SDH)
Multiplexing structure
ETSI
European Telecommunications Standards Institute
ETSI Secretariat
F-06921 Sophia Antipolis CEDEX - FRANCE
Postal address:
650 Route des Lucioles - Sophia Antipolis - Valbonne - FRANCE
Office address:
c=fr, a=atlas, p=etsi, s=secretariat - secretariat@etsi.fr
X.400: Internet:
Tel.: +33 92 94 42 00 - Fax: +33 93 65 47 16
Copyright Notification: No part may be reproduced except as authorized by written permission. The copyright and the
foregoing restriction extend to reproduction in all media.
© European Telecommunications Standards Institute 1995. All rights reserved.
New presentation - see History box
Page 2
ETS 300 147: January 1995
Whilst every care has been taken in the preparation and publication of this document, errors in content,
typographical or otherwise, may occur. If you have comments concerning its accuracy, please write to
"ETSI Editing and Committee Support Dept." at the address shown on the title page.
Page 3
ETS 300 147: January 1995
Contents
Foreword .5
1 Scope .7
2 Normative references.7
3 Definitions and abbreviations .7
3.1 Definitions .7
3.2 Abbreviations .7
4 Hierarchical bit rates.7
5 Basic multiplexing structure .8
6 Multiplexing method and mapping.8
7 Section Overhead (SOH) bytes.11
8 Conformance testing .11
Annex A (informative): Bibliography.13
History.14
Page 4
ETS 300 147: January 1995
Blank page
Page 5
ETS 300 147: January 1995
Foreword
This European Telecommunication Standard (ETS) has been produced by the Transmission and
Multiplexing (TM) Technical Committee of the European Telecommunications Standards Institute (ETSI).
This second edition of ETS 300 147 (1995) supersedes the first edition of ETS 300 147 (1992).
This ETS provides inter-vendor and inter-operator compatibility and is based on ITU-T Recommendations
G.707 [1], G.708 [2] and G.709 [3].
Transposition dates
Date of latest announcement of this ETS (doa): 30 April 1995
Date of latest publication of new National Standard 31 October 1995
or endorsement of this ETS (dop/e):
Date of withdrawal of any conflicting National Standard (dow): 31 October 1995
Page 6
ETS 300 147: January 1995
Blank page
Page 7
ETS 300 147: January 1995
1 Scope
This European Telecommunication Standard (ETS) specifies the hierarchical bit rates, the multiplexing
structure and the mapping schemes to be used in the transmission networks based on Synchronous
Digital Hierarchy (SDH).
2 Normative references
This ETS incorporates by dated and undated reference, provisions from other publications. These
normative references are cited at the appropriate places in the text and the publications are listed
hereafter. For dated references, subsequent amendments to or revisions of any of these publications
apply to this ETS only when incorporated in it by amendment or revision. For undated references the latest
edition of the publication referred to applies.
[1] ITU-T Recommendation G.707 (1993): "Synchronous digital hierarchy bit rates".
[2] ITU-T Recommendation G.708 (1993): "Network node interface for the
synchronous digital hierarchy".
[3] ITU-T Recommendation G.709 (1993): "Synchronous multiplexing structure".
3 Definitions and abbreviations
3.1 Definitions
For the purposes of this ETS, the definitions given in ITU-T Recommendation G.708 [2] apply.
3.2 Abbreviations
For the purposes of this ETS the following abbreviations apply.
ATM Asynchronous Transfer Mode
AU-n Administrative Unit-n
AUG Administrative Unit Group
N Normative
N/R Not Relevant
POH Path Overhead
SDH Synchronous Digital Hierarchy
SOH Section Overhead
STM-N Synchronous Transport Module-N
TU-n Tributary Unit-n
TUG(-n) Tributary Unit Group (-n)
VC-n Virtual Container-n
4 Hierarchical bit rates
The hierarchical bit rates used in the SDH transmission network shall be according to ITU-T
Recommendation G.707 [1].
Page 8
ETS 300 147: January 1995
5 Basic multiplexing structure
The basic SDH multiplexing structure shall be as described in figure 1.
NOTE 1: This SDH multiplexing structure is a subset of the SDH multiplexing structure defined
in ITU-T Recommendation G.709 [3].
NOTE 2: The order of transmission of information in all diagrams in ITU-T Recommendation
G.709 [3] is first from left to right and then from top to bottom. Within each byte, the
most significant bit is transmitted first. The most significant bit (bit 1) is illustrated at the
left in all diagrams.
6 Multiplexing method and mapping
The multiplexing method and mapping are given in ITU-T Recommendation G.709
...