This part of IEC 61169, which is a sectional specification (SS), provides information and rules
for the preparation of detail specifications (DS) for RF coaxial connectors with threaded
coupling, typically for use in 50 Ω cable networks (Type S7-16).
It prescribes mating face dimensions for general purpose connectors – grade 2, dimensional
details of standard test connectors-grade 0, gauging information and tests selected from
IEC 61169-1, applicable to all detail specifications relating to series 4.1-9.5 RF connectors.
This specification indicates recommended performance characteristics to be considered when
writing a detail specification and it covers test schedules and inspection requirements for
assessment levels M and H.
The S7-16 series RF coaxial connectors with nominal impedance 50 Ω are threaded coupling
units which are used with all kinds of RF cables and microstrips in microwave transmission
system. And the working frequency is up to 7,5 GHz.
NOTE Metric dimension are original dimensions. All undimensioned pictorial configurations are for reference
purpose only.
Hochfrequenz-Steckverbinder - Teil 53: Rahmenspezifikation für koaxiale HF-Steckverbinder mit 16 mm Innendurchmesser des Außenleiters und Schraubverriegelung - Wellenwiderstand 50 Ohm (Typ S7-16)
Connecteurs pour fréquences radioélectriques - Partie 53: Spécification intermédiaire relative aux connecteurs coaxiaux pour fréquences radioélectriques avec diamètre intérieur des conducteurs extérieurs de 16 mm à verrouillage à vis – Impédance caractéristique 50 Ohm (Type S7-16)
L'IEC 61169-53:2015 est une spécification intermédiaire (SI), qui fournit des informations et des règles en vue de l'établissement de spécifications particulières (SP) relatives aux connecteurs coaxiaux pour fréquences radioélectriques avec couplage vissé, spécifiquement utilisés dans les réseaux câblés 50 Ohms (Type S7-16).
Radiofrekvenčni konektorji - 53. del: Področna specifikacija za RF koaksialne konektorje z notranjim premerom zunanjih vodnikov 16 mm z navojnim zaklopom - Karakteristična impedanca 50 ohm (tip S7-16) (IEC 61169-53:2015)
Ta del standarda IEC 61169, ki je področna specifikacija (SS), podaja informacije in določa pravila za pripravo podrobnih specifikacij (DS) za radiofrekvenčne koaksialne konektorje s spojko z navojem, običajno za uporabo v 50-ohmskih kabelskih omrežjih (tip S7-16).
Predpisuje prednje mere stikanja za konektorje za splošni namen tipa 2, podrobnosti o merah standardnih preskusnih konektorjev tipa 0, merjenje informacij in preskuse, izbrane iz standarda IEC 61169-1, ki veljajo za vse podrobne specifikacije v zvezi z radiofrekvenčnimi konektorji serije 4.1-9.5. Ta specifikacija določa priporočene lastnosti, ki jih je treba upoštevati pri sestavljanju podrobne specifikacije, ter zajema urnike preskusov in zahteve za pregled za ravni vrednotenja M in H.
Radiofrekvenčni koaksialni konektorji serije S7-16 z nazivno impedanco 50 ohmov so enote s spojko z navojem, ki se uporabljajo z različnimi radiofrekvenčnimi kabli in mikrotrakovi v mikrovalovnem prenosnem sistemu. Omejitev frekvenčnega območja delovanja je do 7,5 GHz.
OPOMBA: Izvirne mere so podane v metričnih merah. Vse nedimenzionirane slikovne konfiguracije so podane samo v referenčne namene.
General Information
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 61169-53:2016
01-april-2016
5DGLRIUHNYHQþQLNRQHNWRUMLGHO3RGURþQDVSHFLILNDFLMD]D5)NRDNVLDOQH
NRQHNWRUMH]QRWUDQMLPSUHPHURP]XQDQMLKYRGQLNRYPP]QDYRMQLP]DNORSRP
.DUDNWHULVWLþQDLPSHGDQFDRKPWLS6,(&
5DGLRIUHTXHQF\FRQQHFWRUV3DUW6HFWLRQDOVSHFLILFDWLRQIRU5)FRD[LDOFRQQHFWRUV
ZLWKLQQHUGLDPHWHURIRXWHUFRQGXFWRUPPZLWKVFUHZORFN&KDUDFWHULVWLFLPSHGDQFH
ȍ7\SH6,(&
Ta slovenski standard je istoveten z: EN 61169-53:2016
ICS:
33.120.30 5DGLRIUHNYHQþQLNRQHNWRUML RF connectors
5)
SIST EN 61169-53:2016 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST EN 61169-53:2016
---------------------- Page: 2 ----------------------
SIST EN 61169-53:2016
EUROPEAN STANDARD EN 61169-53
NORME EUROPÉENNE
EUROPÄISCHE NORM
January 2016
ICS 33.120.30
English Version
Radio-frequency connectors - Part 53: Sectional specification for
RF coaxial connectors with inner diameter of outer conductor 16
mm with screw lock - Characteristic impedance 50 Ohm
(Type S7-16)
(IEC 61169-53:2015)
Connecteurs pour fréquences radioélectriques - Partie 53: Hochfrequenz-Steckverbinder - Teil 53:
Spécification intermédiaire relative aux connecteurs Rahmenspezifikation für koaxiale HF-Steckverbinder mit 16
coaxiaux pour fréquences radioélectriques avec diamètre mm Innendurchmesser des Außenleiters und
intérieur des conducteurs extérieurs de 16 mm à Schraubverriegelung - Wellenwiderstand 50 Ohm (Typ S7-
verrouillage à vis - Impédance caractéristique 50 Ohm 16)
(Type S7-16) (IEC 61169-53:2015)
(IEC 61169-53:2015)
This European Standard was approved by CENELEC on 2015-10-21. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2016 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 61169-53:2016 E
---------------------- Page: 3 ----------------------
SIST EN 61169-53:2016
EN 61169-53:2016
European foreword
The text of document 46F/309/CDV, future edition 1 of IEC 61169-53, prepared by SC 46F "R.F. and
microwave passive components" of IEC/TC 46 "Cables, wires, waveguides, R.F. connectors, R.F. and
microwave passive components and accessories" was submitted to the IEC-CENELEC parallel vote
and approved by CENELEC as EN 61169-53:2016.
The following dates are fixed:
• latest date by which the document has to be (dop) 2016-07-29
implemented at national level by
publication of an identical national
standard or by endorsement
(dow) 2019-01-29
• latest date by which the national
standards conflicting with the
document have to be withdrawn
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such
patent rights.
Endorsement notice
The text of the International Standard IEC 61169-53:2015 was approved by CENELEC as a European
Standard without any modification.
2
---------------------- Page: 4 ----------------------
SIST EN 61169-53:2016
EN 61169-53:2016
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod), the relevant
EN/HD applies.
NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available here:
www.cenelec.eu.
Publication Year Title EN/HD Year
IEC 61169-1 2013 Radio-frequency connectors -- Part 1: EN 61169-1 2013
Generic specification - General
requirements and measuring methods
IEC 62037 series Passive RF and microwave devices, EN 62037 series
intermodulation level measurement
3
---------------------- Page: 5 ----------------------
SIST EN 61169-53:2016
---------------------- Page: 6 ----------------------
SIST EN 61169-53:2016
IEC 61169-53
®
Edition 1.0 2015-09
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
colour
inside
Radio-frequency connectors –
Part 53: Sectional specification for RF coaxial connectors with inner diameter of
outer conductor 16 mm with screw lock – Characteristic impedance 50 Ω (Type
S7-16)
Connecteurs pour fréquences radioélectriques –
Partie 53: Spécification intermédiaire relative aux connecteurs coaxiaux pour
fréquences radioélectriques avec diamètre intérieur des conducteurs extérieurs
de 16 mm à verrouillage à vis – Impédance caractéristique 50 Ω (Type S7-16)
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE
ICS 33.120.30 ISBN 978-2-8322-2878-4
Warning! Make sure that you obtained this publication from an authorized distributor.
Attention! Veuillez vous assurer que vous avez obtenu cette publication via un distributeur agréé.
® Registered trademark of the International Electrotechnical Commission
Marque déposée de la Commission Electrotechnique Internationale
---------------------- Page: 7 ----------------------
SIST EN 61169-53:2016
– 2 – IEC 61169-53:2015 © IEC 2015
CONTENTS
FOREWORD . 4
1 Scope . 6
2 Normative references . 6
3 Mating face and gauge information . 6
3.1 Dimensions – General connectors – Grade 2 . 6
3.1.1 Connector with pin-centre contact . 6
3.1.2 Connector with socket centre contact . 7
3.2 Gauges . 8
3.2.1 Gauge pin for socket-centre contact . 8
3.2.2 Test procedure . 9
3.3 Dimensions – Standard test connectors – Grade 0 . 9
3.3.1 Connector with pin-centre contact . 9
3.3.2 Standard test connector with socket-centre contact . 10
4 Quality assessment procedures . 12
4.1 General . 12
4.2 Ratings and characteristics (see Clause 5 of IEC 61169-1:2013) . 12
4.3 Test schedule and inspection requirements. 14
4.3.1 Acceptance tests . 14
4.3.2 Periodic tests . 14
4.4 Procedures for the quality conformance . 15
4.4.1 Quality conformance inspection . 15
4.4.2 Qualification approval and its maintenance . 16
5 Instructions for preparation of detail specifications . 16
5.1 General . 16
5.2 Identification of the component . 16
5.3 Performances . 16
5.4 Marking, ordering information and related matters . 16
5.5 Selection of tests, test conditions and severities . 16
5.6 Blank detail specification pro-forma for type S7-16 connector . 17
6 Marking . 21
6.1 Marking of component . 21
6.2 Marking and contents of package . 21
Figure 1 – Connector with pin-centre contact (for dimensions, see Table 1) . 7
Figure 2 – Connector with socket-centre contact (for dimensions, see Table 2). 8
Figure 3 – Gauge pin for socket-centre contact (for dimensions, see Table 3) . 9
Figure 4 – Connector with pin-centre contact (for dimensions, see Table 4) . 10
Figure 5 – Connector with socket-centre contact (for dimensions, see Table 5). 11
Table 1 – Dimensions of connector with pin-centre contact . 7
Table 2 – Dimensions of connector with socket centre contact . 8
Table 3 – Dimensions of gauge pin for socket-centre contact . 9
Table 4 – Dimensions of connector with pin-centre contact . 10
Table 5 – Dimensions of connector with socket-centre contact . 11
---------------------- Page: 8 ----------------------
SIST EN 61169-53:2016
IEC 61169-53:2015 © IEC 2015 – 3 –
Table 6 – Rating and characteristics . 12
Table 7 – Acceptance tests . 14
Table 8 – Periodic tests . 15
---------------------- Page: 9 ----------------------
SIST EN 61169-53:2016
– 4 – IEC 61169-53:2015 © IEC 2015
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
RADIO-FREQUENCY CONNECTORS –
Part 53: Sectional specification for RF coaxial connectors
with inner diameter of outer conductor 16 mm with screw lock –
Characteristic impedance 50 Ω (Type S7-16)
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61169-53 has been prepared by subcommittee 46F: RF and
microwave passive components, of IEC technical committee 46: Cables, wires, waveguides,
R.F. connectors, R.F. and microwave passive components and accessories.
The text of this standard is based on the following documents:
FDIS Report on voting
46F/309/CDV 46F/321/RVC
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
---------------------- Page: 10 ----------------------
SIST EN 61169-53:2016
IEC 61169-53:2015 © IEC 2015 – 5 –
A list of all parts of the IEC 61169 series, under the general title: Radio-frequency connectors,
can be found on the IEC website.
The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC website under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
IMPORTANT – The 'colour inside' logo on the cover page of this publication indicates
that it contains colours which are considered to be useful for the correct
understanding of its contents. Users should therefore print this document using a
colour printer.
---------------------- Page: 11 ----------------------
SIST EN 61169-53:2016
– 6 – IEC 61169-53:2015 © IEC 2015
RADIO-FREQUENCY CONNECTORS –
Part 53: Sectional specification for RF coaxial connectors
with inner diameter of outer conductor 16 mm with screw lock –
Characteristic impedance 50 Ω (Type S7-16)
1 Scope
This part of IEC 61169, which is a sectional specification (SS), provides information and rules
for the preparation of detail specifications (DS) for RF coaxial connectors with threaded
coupling, typically for use in 50 Ω cable networks (Type S7-16).
It prescribes mating face dimensions for general purpose connectors – grade 2, dimensional
details of standard test connectors-grade 0, gauging information and tests selected from
IEC 61169-1, applicable to all detail specifications relating to series 4.1-9.5 RF connectors.
This specification indicates recommended performance characteristics to be considered when
writing a detail specification and it covers test schedules and inspection requirements for
assessment levels M and H.
The S7-16 series RF coaxial connectors with nominal impedance 50 Ω are threaded coupling
units which are used with all kinds of RF cables and microstrips in microwave transmission
system. And the working frequency is up to 7,5 GHz.
NOTE Metric dimension are original dimensions. All undimensioned pictorial configurations are for reference
purpose only.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and
are indispensable for its application. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any
amendments) applies.
IEC 61169-1:2013, Radio frequency connectors – Part 1: Generic specification – General
requirements and measuring methods
IEC 62037-3 (all parts), Passive RF and microwave devices, intermodulation level
measurement
3 Mating face and gauge information
3.1 Dimensions – General connectors – Grade 2
3.1.1 Connector with pin-centre contact
The mating face of connector with pin-centre contact is shown in Figure 1 and its dimensions
are shown in Table 1.
---------------------- Page: 12 ----------------------
SIST EN 61169-53:2016
IEC 61169-53:2015 © IEC 2015 – 7 –
f
135°
r
k
h
i
Note 3
j
s
IEC
1
The tolerance on this dimension is determined by the tolerance of characteristic impedance.
2
The design of this dimension should meet sealing performance at the same time the electrical requirements.
3
Mechanical and electrical reference plane
Figure 1 – Connector with pin-centre contact (for dimensions, see Table 1)
Table 1 – Dimensions of connector with pin-centre contact
mm
Reference Additional notes
Min. Max.
a M22×1
b 17,87 18,03
c 4,80 4,86
d 7 (nominal) 1
e 16,02 °16,08
f 1,00 1,50
h 1,80 2,20
i 4,20 4,50
j 5,20 5,50
s 7,80 – 2
k 0,00 1,00
l 22,05 22,35
m – 3,70
r 0,12 0,30
3.1.2 Connector with socket centre contact
The mating face of connector with socket centre contact is shown in Figure 2 and its
dimensions are shown in Table 2.
∅l
a
∅b
∅c
∅m
∅d
∅e
---------------------- Page: 13 ----------------------
SIST EN 61169-53:2016
– 8 – IEC 61169-53:2015 © IEC 2015
Detail I
p
q
Note 4
s I
r
1
r
2
t
0,6 × 45°
Note 5
m
IEC
1
The design of this dimension should meet gauge test of 3.2.1 and reflection factor requirement.
2
The tolerance on this dimension is determined by the tolerance of characteristic impedance.
3
Slot design optional. Contact to be closed to meet electrical and mechanical request.
4
Root cut.
5
Mechanical and electrical reference plane
Figure 2 – Connector with socket-centre contact (for dimensions, see Table 2)
Table 2 – Dimensions of connector with socket centre contact
mm
Reference Additional notes
Min. Max.
a M22×1
c – – 1
d 7 (nominal) 2
e 16,02 16,08
n 18,05 18,13
p 9,50 –
q 7,50 –
s 6,70 7,00
t 4,90 5,20
m 5,00 –
z – – 3
r 0,20 0,35
1
0,20 0,35
r
2
3.2 Gauges
3.2.1 Gauge pin for socket-centre contact
The gauge pin for socket-centre contact is shown in Figure 3 and its dimensions are shown in
Table 3.
z
∅c
∅d
∅e
∅n
a
---------------------- Page: 14 ----------------------
SIST EN 61169-53:2016
IEC 61169-53:2015 © IEC 2015 – 9 –
30°
R 0,5
∅a
IEC
Figure 3 – Gauge pin for socket-centre contact (for dimensions, see Table 3)
Table 3 – Dimensions of gauge pin for socket-centre contact
Gauge A Gauge B
(For sizing purpose) (For measurement of retention force)
+5
Mass of gauge:1 000 g
0
Ref.
mm mm
Min. Max. Min. Max.
a 4,91 4,92 4,81 4,82
b 2,00 3,00 2,00 3,00
c 4,50 5,00 4,50 5,00
Material: steel, 0,4 µm maximum finish.
3.2.2 Test procedure
a) Sizing test
The gau
...