IEC 61076-2-115:2023 describes free and fixed 12P shielded circular connectors with 2 A rated current, rated voltage up to and including 50 V AC/DC, IP65/IP67 metal housing with push-pull locking (hereinafter referred to as a connectors) for use in electrical and electronic equipment. It includes overall dimensions, interface dimensions, technical characteristics, performance requirements and test methods.

  • Standard
    39 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    30 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document defines a number of conditions common to rectangular electrical modular connectors for receptacles, plugs and rack and panel, with interchangeable modules and continuous operating temperature 175 °C.

  • Standard
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61076-8-105:2023 applies to free and fixed 2-pole snap locking rectangular power connectors with plastic housing with rated current 63 A and rated voltage up to 400 V. It includes overall dimensions, interface dimensions, technical characteristics, performance requirements, test methods.

  • Standard
    59 pages
    English and French language
    sale 15% off

IEC 61076-3-106:2023 constitutes a detail product specification for 8-way connectors for data transmission with frequencies up to 600 MHz.
It covers protective housings for upgrading existing 8-way shielded and unshielded connectors utilizing the interface described in the IEC 60603-7 series to IP65/IP67 rating according to IEC 60529, for use in industrial environments.
The housings cover a variety of different locking mechanisms according to this document and a variety of different mounting configurations and termination types which are detailed in the IEC 60603-7 series.
Common mating configurations for all variants are defined in IEC 60603-7. The mating dimensions for the housings under Clause 3 allow the mating conditions under IEC 60603-7 to be fulfilled.
The fully assembled variants (connectors) described in this document incorporate fully compliant IEC 60603-7 series fixed and free connectors.

  • Standard
    74 pages
    English and French language
    sale 15% off

IEC 61076-2-115:2023 describes free and fixed 12P shielded circular connectors with 2 A rated current, rated voltage up to and including 50 V AC/DC, IP65/IP67 metal housing with push-pull locking (hereinafter referred to as a connectors) for use in electrical and electronic equipment. It includes overall dimensions, interface dimensions, technical characteristics, performance requirements and test methods.

  • Standard
    39 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    30 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This International Standard retains IEC 61984:2008 as the minimum performance requirements for railway rolling stock electrical connectors.
It identifies additional terms, test methods and performance requirements for single-pole and multipole connectors with rated voltages up to 1 000 V, rated currents up to 125 A per contact and frequencies below 3 MHz used for indoor and outdoor applications in railway rolling stock.
This International Standard does not cover:
- connectors with breaking capacity (CBCs) as defined in IEC 61984:2008, 3.2, because on board rolling stock connectors are not intended to be operated (i.e. mated and unmated) under load or when live, either by means of procedures or by the presence of interlocks, as required by IEC 61991;
- non-rewirable connectors as defined in IEC 61984:2008, 3.5;
- automatic couplers, due to their additional mechanical complexity and the need for more specific requirements and testing;
- inter-vehicle jumpers, as they are connector and cable assemblies whose characteristics depend on those of both elements. Inter-vehicle connectors within the limits set in the scope of this International Standard are therefore covered by the agreed choice of suitable mechanical and environmental characteristics as defined by Annex B, and suggested by Annex C.
This International Standard identifies the application levels for electrical connectors based on
a) the severity of the service conditions in different rolling stock technologies,
b) the intended use of the rolling stock,
c) the location of the connector in the rolling stock system.
This International Standard is not applicable to internal connections of electronic devices such as connectors for printed boards and rack-and-panel connectors.

  • Standard
    53 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    52 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61076-2-115:2023 describes free and fixed 12P shielded circular connectors with 2 A rated current, rated voltage up to and including 50 V AC/DC, IP65/IP67 metal housing with push-pull locking (hereinafter referred to as a connectors) for use in electrical and electronic equipment. It includes overall dimensions, interface dimensions, technical characteristics, performance requirements and test methods.

  • Standard
    68 pages
    English and French language
    sale 15% off

IEC 63171-7:2023 covers shielded free and fixed circular connectors with 4 ways up to 7 ways for power and data transmission and specifies the common dimensions, mechanical, electrical and transmission characteristics and environmental requirements as well as test specifications respectively.
The connectors described in this document are either equipped with an M12 screw-locking mechanism (styles with M12 in the name) or a quick-locking push-pull mechanism with a size derived from that (styles with P12 in the name) or both mechanisms combined (styles with C12 in the name). For the sake of simplicity, the connectors' size is denoted as "size 12" in this document.
This document provides multiple mating interfaces each of which is associated with a coding preventing the mating of incompatible male and female connectors. These codings are referred to as "Type x", where "x" is represented by a Roman numeral.
For all codings, two ways and the additional shield pin, which is intended to be connected to the cable screen, support differential data transmission with frequencies up to 600 MHz by meeting the requirements of Category B, as defined in IEC 63171.

  • Standard
    33 pages
    English language
    sale 15% off

IEC 61076-8-109:2023 describes free and fixed rectangular connectors with:
- 2P power plus 2P signal contacts;
- plastic housing with locking lever and four possible codings;
- 130 A rated current, 1 000 V DC rated voltage on the power section;
- 5 A rated current, 50 V DC rated voltage on the signal section;
- individual shielding around each power contact with relevant shielding termination;
- IP65/IP68 degree of protection when mated and locked and IPXXB on both plug, and receptacle parts when unmated;
- hereinafter referred to as a connector, for use in electrical and electronic equipment, including overall dimensions, interface dimensions, technical characteristics, performance requirements and test methods.

  • Standard
    75 pages
    English and French language
    sale 15% off

IEC 61076-8-107:2023 describes free and fixed rectangular connectors with:
- 2P power plus 2P signal contacts;
- plastic housing with locking lever and four possible codings;
- 200 A rated current, 1 000 V DC rated voltage on the power section;
- 5 A rated current, 50 V DC rated voltage on the signal section;
- individual shielding around each power contact with relevant shielding termination;
- IP65/IP68 degree of protection when mated and locked, and IPXXB on both plug and receptacle parts when unmated;
- hereinafter referred to as a connector, for use in electrical and electronic equipment, including overall dimensions, interface dimensions, technical characteristics, performance requirements and test methods.

  • Standard
    75 pages
    English and French language
    sale 15% off

IEC 61076-8-103:2023 describes free and fixed 2-pole power (1P+N) plus PE circular connectors with 20 A rated current, rated voltage up to and including 300 V AC, IP65/IP67 metal housing with push-pull locking (hereinafter referred to as a connectors) for use in electrical and electronic equipment. It includes overall dimensions, interface dimensions, technical characteristics, performance requirements and test methods.

  • Standard
    68 pages
    English and French language
    sale 15% off

IEC 61076-8-108:2023 describes free and fixed rectangular connectors with:
- 2P power plus 2P signal contacts;
- plastic housing with locking lever and four possible codings;
- 250 A rated current, 1 000 V DC rated voltage on the power section;
- 5 A rated current, 50 V DC rated voltage on the signal section;
- individual shielding around each power contact with relevant shielding termination;
- IP65/IP68 degree of protection when mated and locked, and IPXXB on both plug and receptacle parts when unmated, hereinafter referred to as a connector, for use in electrical and electronic equipment, including overall dimensions, interface dimensions, technical characteristics, performance requirements and test methods.

  • Standard
    74 pages
    English and French language
    sale 15% off

IEC 61076-8-104:2023 describes free and fixed 2-pole circular power connectors with 40 A rated current, rated voltage up to and including 50 V AC/DC, and push-pull locking IP65/IP67 metal housings (hereinafter referred to as connectors) for use in electrical and electronic equipment. It includes overall dimensions, interface dimensions, technical characteristics, performance requirements and test methods.

  • Standard
    67 pages
    English and French language
    sale 15% off

IEC 61076-3-126:2023 covers 5-pole rectangular connectors for electric power supply up to 16 A per pole. These connectors consist of fixed and free connectors, both either rewirable or non-rewirable. This document employs the general function principles of the push-pull connector housing system described in IEC 61076‑3‑117 with IP65/IP67 degree of protection according to IEC 60529 for harsh applications.
Male connectors have pin contacts with square cross-section with 1 mm side. Connectors according to this document are without breaking capacity COC according to IEC 61984, therefore they are not intended to be engaged or disengaged in normal use when live or under load.

  • Standard
    49 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61076-2-116:2022 specifies circular connectors size 15 with bayonet-locking, with up to 3 power contacts with rated insulation voltage up to 630 V AC/DC and rated current up to 20 A, plus PE, and up to 3 auxiliary contacts with rated insulation voltage up to 63 V AC/DC and rated current up to 10 A, that are typically used for industrial power supply and power applications, such as the feeding and control of 3-phase asynchronous motors. These connectors consist of both fixed and free connectors either rewireable or non-rewireable, with bayonet-locking. Male connectors have round contacts, either power or signal, Ø1,6 mm.

  • Standard
    48 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    45 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61076-2-116:2022 specifies circular connectors size 15 with bayonet-locking, with up to 3 power contacts with rated insulation voltage up to 630 V AC/DC and rated current up to 20 A, plus PE, and up to 3 auxiliary contacts with rated insulation voltage up to 63 V AC/DC and rated current up to 10 A, that are typically used for industrial power supply and power applications, such as the feeding and control of 3-phase asynchronous motors. These connectors consist of both fixed and free connectors either rewireable or non-rewireable, with bayonet-locking. Male connectors have round contacts, either power or signal, Ø1,6 mm.

  • Standard
    48 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    45 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document defines the performance and contact arrangements of circular electrical connectors, coupled by threaded ring. It also lists the product standards and models available for selection in this series.

  • Standard
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60512-28-100:2019 is available as IEC 60512-28-100:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60512-28-100:2019 specifies the test methods for signal integrity and transmission performance for connectors specified in respective parts of IEC 60603-7, IEC 61076-1, IEC 61076-2, and IEC 61076-3 standards for connecting hardware applications up to 2 000 MHz. It is also suitable for testing lower frequency connectors, however, the test methodology specified in the detail specification for any given connector remains the reference conformance test for that connector. The above list of connector series of standards does not preclude referencing this document in other connector manufacturer’s specifications or published standards. Test procedures provided herein are: - insertion loss, test 28a; - return loss, test 28b; - near-end crosstalk (NEXT) test 28c; - far-end crosstalk (FEXT), test 28d; - transverse conversion loss (TCL), test 28f; - transverse conversion transfer loss (TCTL), test 28g. Other test procedures referenced herein are: - transfer impedance (ZT), see IEC 60512-26-100, test 26e. - for coupling attenuation (aC), see IEC 62153 4 12. This second edition cancels and replaces the first edition, issued in 2013, and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - The title is revised from 1 000 MHz to 2 000 MHz to reflect the range of frequencies which may be tested. - All tables and requirements have been revised up to 2 000 MHz. Key words: Connectors, Signal Integrity Tests

  • Standard
    50 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61076-2-116:2022 specifies circular connectors size 15 with bayonet-locking, with up to 3 power contacts with rated insulation voltage up to 630 V AC/DC and rated current up to 20 A, plus PE, and up to 3 auxiliary contacts with rated insulation voltage up to 63 V AC/DC and rated current up to 10 A, that are typically used for industrial power supply and power applications, such as the feeding and control of 3-phase asynchronous motors. These connectors consist of both fixed and free connectors either rewireable or non-rewireable, with bayonet-locking. Male connectors have round contacts, either power or signal, Ø1,6 mm.

  • Standard
    85 pages
    English and French language
    sale 15% off

This part of IEC 63171 describes shielded or unshielded circular connectors with 2 ways and M8 or M12 Styles, typically used for data transmission up to 600 MHz and with current carrying capacity up to 4 A, for use in areas with harsh environmental conditions. These connectors consist of fixed and free connectors either rewirable or non-rewirable. Male connectors have square cross- section contacts, for data and power transmission.
M12 describes the dimensions of the styles and thread of the screw-locking mechanism according IEC 61076-2-101 of this size of circular connectors. M8 describes the dimensions of the styles and thread of the screw-locking mechanism according IEC 61076-2-104. The use of alternative locking mechanisms according to IEC 61076-2-010 or IEC 61076-2-011 are possible.
The coding provided by this standard prevents the mating of accordingly coded male or female connectors to other similarly sized interfaces covered by this or other standards.
These Type 5 connectors are interoperable with Type 2 connectors according IEC 63171-2, except the locking and sealing system provided by the outer shell.
The shielded and unshielded connectors are interoperable for their internal transmission performance and can be exchanged. The shielded version has improved EMC and coupling properties.
This part of IEC 63171 covers Type 5 connectors. Each part of this series has the associated type number equal to the number of the part in the series. All connectors in the IEC 63171 series are deemed to provide the same functions as defined in IEC 63171:2021, using different mechanical interfaces.

  • Standard
    36 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    30 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60512 covers additional, supplemental test method specifications to extend the
upper frequency for the test connectors and associated indirect-reference test fixtures used in
the signal integrity and transmission performance tests specified in IEC 60512-27-100. In
support of de-embedded crosstalk and related transmission requirements specified in
IEC 60603-7-81, for frequencies up to 2 000 MHz, these supplemental specifications extend
the upper test frequency from IEC 60512-27-100 up to 500 MHz to the upper test frequency of
IEC 60512-28-100 up to 2 000 MHz.
This document covers measurements of connector signal integrity and transmission
performance of 8-way connector types defined in these published connector series standards:
IEC 60603-7-2
IEC 60603-7-3
IEC 60603-7-4
IEC 60603-7-5
IEC 60603-7-41
IEC 60603-7-51
IEC 60603-7-81.
This document covers respective performance test procedures of connector signal integrity and
transmission performance defined in these published connector test method series standards:
IEC 60512-26-100
IEC 60512-27-100
IEC 60512-28-100.
These additional specifications are also suitable for testing the series related lower frequency
backward compatible connectors. However, the actual measurement or test procedure specified
in the detail specification for any particular connector remains the reference conformance test
for that connector category; see Table 1.
The test procedures of IEC 60512-27-100 affected by these supplemental specifications are:
– insertion loss, test 27a;
– return loss, test 27b;
– near-end crosstalk (NEXT) test 27c;
– far-end crosstalk (FEXT), test 27d;
– transverse conversion loss (TCL), test 27f;
– transverse conversion transfer loss (TCTL), test 27g.
– transfer impedance (ZT), see IEC 60512-26-100, test 26e.
– 8 – IEC 60512-27-200:2022 © IEC 2022
– coupling attenuation (aC), see IEC 62153-4-12.

  • Standard
    32 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60512-27-200:2022 is primarily intended for use in signal integrity and transmission performance testing up to 2 000 MHz of IEC 60603-7 series 8-way connector type IEC 60603‑7‑81, according to connector test method IEC 60512‑28‑100. This part of IEC 60512 covers additional, supplemental test method specifications to extend the upper frequency for the test connectors and associated indirect-reference test fixtures used in the signal integrity and transmission performance tests specified in IEC 60512‑27‑100. In support of de-embedded crosstalk and related transmission requirements specified in IEC 60603‑7‑81, for frequencies up to 2 000 MHz, these supplemental specifications extend the upper test frequency from IEC 60512‑27‑100 up to 500 MHz to the upper test frequency of IEC 60512‑28‑100 up to 2 000 MHz. This document covers measurements of connector signal integrity and transmission performance of 8-way connector types defined in these published connector series standards: - IEC 60603‑7‑2 - IEC 60603‑7‑3 - IEC 60603‑7‑4 - IEC 60603‑7‑5 - IEC 60603‑7‑41 - IEC 60603‑7‑51 - IEC 60603‑7‑81. This document covers respective performance test procedures of connector signal integrity and transmission performance defined in these published connector test method series standards: - IEC 60512‑26‑100 - IEC 60512‑27‑100 - IEC 60512‑28‑100.

  • Standard
    32 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 63171 describes shielded or unshielded circular connectors with 2 ways and M8 or M12 Styles, typically used for data transmission up to 600 MHz and with current carrying capacity up to 4 A, for use in areas with harsh environmental conditions. These connectors consist of fixed and free connectors either rewirable or non-rewirable. Male connectors have square cross- section contacts, for data and power transmission. M12 describes the dimensions of the styles and thread of the screw-locking mechanism according IEC 61076-2-101 of this size of circular connectors. M8 describes the dimensions of the styles and thread of the screw-locking mechanism according IEC 61076-2-104. The use of alternative locking mechanisms according to IEC 61076-2-010 or IEC 61076-2-011 are possible. The coding provided by this standard prevents the mating of accordingly coded male or female connectors to other similarly sized interfaces covered by this or other standards. These Type 5 connectors are interoperable with Type 2 connectors according IEC 63171-2, except the locking and sealing system provided by the outer shell. The shielded and unshielded connectors are interoperable for their internal transmission performance and can be exchanged. The shielded version has improved EMC and coupling properties. This part of IEC 63171 covers Type 5 connectors. Each part of this series has the associated type number equal to the number of the part in the series. All connectors in the IEC 63171 series are deemed to provide the same functions as defined in IEC 63171:2021, using different mechanical interfaces.

  • Standard
    36 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    30 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60364-5-57:2022 provides requirements and recommendations for the design, erection, correct use and protection of installations with secondary stationary batteries as prime storage medium, hereinafter referred to as "stationary secondary batteries".
This document is not applicable to products such as batteries and to systems design (including batteries) which are already covered by their own IEC standard.

  • Standard
    50 pages
    English and French language
    sale 15% off

IEC 61076-3-123:2019. covers hybrid rectangular connectors with a 3 poles 16 A electric portion for power supply and a duplex fibre optic connector type LC portion for data transmission. These connectors consist of fixed and free connectors, either rewirable or non-rewirable (for both portions) and use the rectangular push-pull housing described in IEC 61076-3-117 with IP65/IP67 degree of protection, for harsh applications. The mating dimensions of such housings allow fulfilling the performance class Category I according to IEC 61753-1-3 in regards to the fibre optic portion of the connector with the exception of the operating temperature range which is –25 °C/+70 °C. The electric portion may have different rated insulation voltages. Male connectors have 3 electric round contacts Ø1,6 mm, with 16 A rated current. The fibre optic portion provides data transmission by using the common mating configurations for all variants of the type LC duplex fibre optic connectors as defined in IEC 61754-20, for dedicated fibre types and fibre termination technology covered therein. The different codings provided by this document prevent the mating of accordingly coded male or female connectors to any other similarly sized interfaces covered by other standards and the cross-mating between the different codings provided by this document. Key words: Rectangular Connectors, Hybrid Connectors, Power Supply and Fiber Optic Data Transmission.

  • Standard
    51 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the general characteristics, the conditions for qualification, acceptance and quality assurance, as well as the test programs and groups for threaded ring coupling circular connectors, fire resistant, intended for use in a temperature range from -65 °C to 175 °C continuous or 200 °C continuous according to the classes.

  • Standard
    107 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    109 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 63171-5:2022 refers to International Standards for test and measurement, environmental testing as well as solderless connections. This part of IEC 63171 describes 2-way shielded or unshielded circular connectors with IP65/IP67 M8 or M12 locking, typically used for balanced single-pair data transmission with frequencies up to 600 MHz and with current-carrying capacity up to 4 A, for use in areas with harsh environmental conditions. These connectors consist of fixed and free connectors, either rewirable or non-rewirable. Male connectors have square cross-section contacts.

  • Standard
    65 pages
    English and French language
    sale 15% off

IEC 60512-27-200:2022 is primarily intended for use in signal integrity and transmission performance testing up to 2 000 MHz of IEC 60603-7 series 8-way connector type IEC 60603‑7‑81, according to connector test method IEC 60512‑28‑100.
This part of IEC 60512 covers additional, supplemental test method specifications to extend the upper frequency for the test connectors and associated indirect-reference test fixtures used in the signal integrity and transmission performance tests specified in IEC 60512‑27‑100. In support of de-embedded crosstalk and related transmission requirements specified in IEC 60603‑7‑81, for frequencies up to 2 000 MHz, these supplemental specifications extend the upper test frequency from IEC 60512‑27‑100 up to 500 MHz to the upper test frequency of IEC 60512‑28‑100 up to 2 000 MHz. This document covers measurements of connector signal integrity and transmission performance of 8-way connector types defined in these published connector series standards:
- IEC 60603‑7‑2
- IEC 60603‑7‑3
- IEC 60603‑7‑4
- IEC 60603‑7‑5
- IEC 60603‑7‑41
- IEC 60603‑7‑51
- IEC 60603‑7‑81.
This document covers respective performance test procedures of connector signal integrity and transmission performance defined in these published connector test method series standards:
- IEC 60512‑26‑100
- IEC 60512‑27‑100
- IEC 60512‑28‑100.
This first edition cancels and replaces IEC/PAS 60512-27-200, published in 2018.

  • Standard
    59 pages
    English and French language
    sale 15% off

IEC 63171-4:2022 covers shielded and unshielded free and fixed multimedia connectors (MMC) for data transmission with frequencies up to and above 3 000 MHz for shielded and up to 600 MHz for unshielded connectors, both with current-carrying capacity with up to 8 ways. It specifies the common dimensions, mechanical, electrical and transmission characteristics and environmental requirements as well as test specifications, respectively. The form factor of these connectors allows their use for cable sharing with TOs (Telecommunications Outlet) for structured cabling. This document covers type 4 connectors. Each part of this series has the associated type number equal to the number of the part in the series. All connectors in the IEC 63171 series are deemed to provide the same functions as defined in IEC 63171, using different mechanical interfaces. The shielded and unshielded connectors are interoperable for their internal transmission performance and can be exchanged. The shielded version has improved EMC and coupling properties. The connectors are intended to be used for Single Pair Ethernet (SPE) according, but not restricted to the following IEEE standards: 10Base-T1 (IEEE 802.3cg), 100Base-T1 (IEEE 802.3bw), 1000Base-T1 (IEEE 802.3bp), Multi-Gig Base-T1 (IEEE 802.3ch) and optionally with Power over Data line (PoDL) power supply according to IEEE 802.3bu.
The contents of the corrigendum 1 (2023-08) have been included in this copy.

  • Standard
    27 pages
    English language
    sale 15% off

IEC 61169-24:2019 is available as IEC 61169-24:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61169-24:2019, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for RF coaxial connectors with screw coupling, typically for use in 75 W cable networks (type F). It describes the interface dimensions with gauging information and the mandatory tests selected from IEC 61169-1, applicable to all DS relating to type F connectors. This specification indicates the recommended performance characteristics to be considered when writing a DS and covers test schedules and inspection requirements. This third edition cancels and replaces the second edition published in 2009. This edition includes the following significant technical changes with respect to the previous edition: all drawings have been reworked and improved to allow frequency extension up to 3 GHz.

  • Standard
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60512-11-1:2019 when required by the detail (product) specification, is used for testing connectors within the scope of IEC technical committee 48. This test may also be used for similar devices (i.e. when the degradation mechanisms are the same) when specified in a detail (product) specification. The object of this test is to define a standard test method to assess the ability of connectors to function in a specified manner, in a specified environment which might be encountered during normal use, including storage. This document provides a standard composite test method for determining the suitability of connectors when subjected to environmental conditions consisting of a sequence of temperature, humidity and, where required, low air pressure environmental stresses. Key words: Connectors, Climatic Tests

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This product standard defines a range of cable outlets, style K, straight, shielded, sealed, self-locking (anti-rotational), heat shrinkable boot, and / or metallic bands for use under the following conditions:
The mating connectors are listed in EN 3660-002.
Temperature range,   Class N   :   - 65 °C to 200 °C;
Class K   :   - 65 °C to 260 °C;
Class W   :   - 65 °C to 175 °C;
Class T   :   - 65 °C to 175 °C (Nickel PTFE plating);
Class Z   :    - 65 °C to 175 °C (Black zinc nickel plating).
Associated electrical accessories: EN 3660-033 Metallic band (for shield termination).
These cable outlets are designed for termination of overall shielding braid and / or individual cable shields. They accommodate/permit the termination of heat shrinkable boots.

  • Standard
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This product standard defines a range of cable outlets, style K, 90°, shielded, sealed, self-locking (anti rotational) for heat shrinkable boot, and or with metallic bands under the following conditions.
The mating connectors are listed in EN 3660-002.
Temperature range,   Class N   :   - 65 °C to 200 °C;
Class K   :   - 65 °C to 260 °C;
Class W   :   - 65 °C to 175 °C;
Class T   :   - 65 °C to 175 °C (Nickel PTFE plating);
Class Z   :   - 65 °C to 175 °C (Black zinc nickel plating).
Associated electrical accessories   : EN 3660-033 Metallic band (for shield termination).
These cable outlets are designed for termination of overall shielding braid and / or individual cable shields. They accommodate/permit the termination of heat shrinkable boots.

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This product standard defines a range of cable outlets, style K, straight, shielded, sealed, self-locking (anti-rotational), heat shrinkable boot, and / or metallic bands for use under the following conditions:
Associated electrical connector(s) EN 3660-002.
Temperature range,   Class N   :   - 65 °C to 200 °C;
Class K   :   - 65 °C to 260 °C;
Class W   :   - 65 °C to 175 °C;
Class T   :   - 65 °C to 175 °C (Nickel PTFE plating);
Class Z   :    - 65 °C to 175 °C (Black zinc nickel plating).
Associated electrical accessories: EN 3660-033 Metallic band (for shield termination).
These cable outlets are designed for termination of overall shielding braid and/or individual cable shields. They accommodate/permit the termination of heat shrinkable boots.

  • Standard
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This product standard defines a range of cable outlets, style K, 90°, shielded, sealed, self-locking (antirotational), for heat shrinkable boot, and/ or metallic bands for use under the following conditions:
The mating connectors are listed in EN 3660-002.
Temperature range, Class N : − 65 °C to 200 °C;
Class K : − 65 °C to 260 °C;
Class W : − 65 °C to 175 °C;
Class T : − 65 °C to 175 °C (Nickel PTFE plating);
Class Z : − 65 °C to 175 °C (Black zinc nickel plating).
Associated electrical accessories: EN 3660-033 Metallic band (for shield termination).
These cable outlets are designed for termination of overall shielding braid and/or individual cable
shields. They accommodate/permit the termination of heat shrinkable boots.

  • Standard
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 61076 covers 10-way, shielded, free and fixed rectangular connectors for data transmission with frequencies up to 500 MHz and specifies the common dimensions, mechanical, electrical and transmission characteristics and environmental requirements as well as test specifications respectively. Connectors covered in this document are provided in three codings that differ only for the position of the polarization key and keyway, in view of their differently intended use: - Connectors Type A and C are intended for 10/100 Mbit/s as well as for 1/ 2,5 / 5 /10 Gbit/s Ethernet communication. - Connectors Type B are intended for all other non-Ethernet applications such as signalling, serial or other industrial bus communication systems. A-coding: The 45° cut corner used as polarization key and keyway system is located on the lower left corner of the male fixed connector (viewed from mating face) (Figures 5a, 5b). B-coding: The 45° cut corner is located on the upper left corner of the male fixed connector (Figures 5c, 5d). C-coding: There are two 45° corners located at the upper left and lower left corner (Figures 5e, 5f). In this document, the three codings, A, B, and C are designated as "Type A", "Type B" and .Type C".

  • Standard
    48 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60512 is used for testing connectors within the scope of SC 48B that are used in twisted pair communication cabling with remote power, such as ISO/IEC 11801 Class D (or better), balanced cabling in support of IEEE Std 802.3bt, (PoE Plus - Power over Ethernet Plus). The object of this document is to detail a test schedule to determine the ability of pairs of connectors to withstand a sequence of tests with a total of 100 engagements and separations. The electrical current is passed through the connectors during the separation (unmating) step only, in accordance with IEC 60512-9-3.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60512 is used for the assessment of connectors within the scope of SC 48B
that are used in twisted pair communication cabling with remote power, such as
ISO/IEC 11801-1 Class D, or better, balanced cabling in support of IEEE 802.3btTM (Power over
Ethernet, supporting up to 90 W from the power sourcing equipment).
The object of this document is to detail a test schedule to determine the ability of sets of
connectors to withstand a minimum of 100 mechanical operations with electrical load, where an
electrical current is being passed through the connectors in accordance with IEC 60512-9-3
during the separation (unmating) step.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60512 is used for the assessment of connectors within the scope of SC 48B that are used in twisted pair communication cabling with remote power, such as ISO/IEC 11801-1 Class D, or better, balanced cabling in support of IEEE 802.3btTM (Power over Ethernet, supporting up to 90 W from the power sourcing equipment). The object of this document is to detail a test schedule to determine the ability of sets of connectors to withstand a minimum of 100 mechanical operations with electrical load, where an electrical current is being passed through the connectors in accordance with IEC 60512-9-3 during the separation (unmating) step.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 61020 specifies the terminology, symbols, test methods and other necessary information to provide consistency in detail specifications for electromechanical switches. This document relates to electromechanical switches intended for use in electrical and electronic appliances. Switches covered by this document: a) are devices which open, close, or change the connection of a circuit by the mechanical motion of conducting parts (contacts); b) have a maximum rated voltage of 480 V; c) have a maximum rated current of 63 A. This document does not include keyboards and keypads which are intended for use in information-handling systems. Electromechanical key switches can be included under the scope of this document. Switch families will be described in any detail specifications that reference this document. This document is a performance standard intended to describe evaluation methods to better clarify the capabilities of a switch. NOTE 1 Safety requirements for switches for household and similar fixed electrical installations are given in IEC 60669 (all parts). NOTE 2 Safety requirements for appliance switches are given in IEC 61058 (all parts).

  • Standard
    90 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    90 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 60512 defines a standard test method for measuring the shielding effectiveness SE of a shielded connector, or of a connector not provided with integral shield once fitted with a shielding accessory and terminated with a screened cable. The complete assembly has a continuous 360° shielding capability throughout its length. NOTE 1 Practically, continuous 360° shielding is not always achievable based on the geometry of the connector. NOTE 2 Shielding" is used in this document with the same meaning as "screening". This test method can be applied to shielded connectors and to connector accessories with shielding capability. The following different connector designs can be tested: - circular connectors; - rectangular connectors; - connectors for printed boards; - connector shielding accessories. NOTE 3 For the definition of "accessory" see IEV 581-24-10. A shielding accessory i.e. an accessory that confers shielding to a non-inherently shielded connector, may be a suitable set of shielded housings providing electrical continuity, along the mated connector set, between the screen of the (screened) cable at the cable outlet of the free cable connector housing and the metallic mounting surface for the fixed connector housing. The free connector housing is provided with a cable screen clamp. This test method utilizes the principle that the intrinsic shielding property of the connector/accessory/cable assembly is its surface transfer impedance ZT which can be expressed as the longitudinal voltage inside the shield, relative to the current flow on the outside shell. This test method is based on two impedance-matched circuits. See Figure 1 for the measurement principle. The connector specimen under test is integrated into the secondary circuit 02. The impedance-matched injection line of the primary circuit 01, which activates the electromagnetic field, runs parallel to the surface of the specimen under test. This test is also suitable for measuring the shielding effectiveness of a connector fitted with triaxial contacts terminated with shielded, twisted pair cables, as used in data bus systems. NOTE 4 This standard has been adopted by ASD-STAN (formerly known as AECMA) as EN 2591-212.

  • Standard
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60512-1:2018 is available as IEC 60512-1:2018 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60512-1:2018 is intended to be used as a basis for tests and measurements specifications for electrical connectors. It provides guidance and reference for tests and measurements within the IEC 60512 series. It includes the description and the practice of the various phases of tests and measurements (preparation, tests and measurements, requirements, documentation), in addition to basic terms and definitions applicable to any part of the IEC 60512 series. This standard shall be used in conjunction with IEC 60512-1-101 and relevant part(s) of series IEC 60512. Part 60512-1-100 provides the list of the existing test and measuring methods published within series IEC 60512. Detail tests and measurements specifications are applicable to electrical connectors and their components (e.g. connector inserts, connector housings, locking mechanisms, contacts and terminations) within the scope of technical committee 48. They may also be used for similar devices when specified in a detail product specification. Detail tests and measurements specifications are used in conjunction with detail product specifications which prescribe the tests to be used, the required degree of severity for each of them and the permissible performance limits. The detail product specification also specifies the deviations in procedures, which may be required when applying a test to the type of connector or its component under consideration, and it further specifies any special procedures which may be required. This fifth edition cancels and replaces the fourth edition, published in 2001. It constitutes a technical revision. This edition includes the following main technical changes with respect to the previous edition: – in Clause 3, only terms relating to the testing are defined, and IEC 61076-1 is referred to for terms of connectors. – Clause 4 (Numbering of tests and measurement specification) is added. – Subclause 5.1.2 (Calibration) is added. – in Clause 6 (Test), test procedure follows IEC 60068-1. Key words: Connectors, Test Specification

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 63171-6:2021 covers 2-way and 4-way (data/power), shielded, free and fixed connectors for data transmission with frequencies up to 600 MHz and specifies the common dimensions, mechanical, electrical and transmission characteristics and environmental requirements as well as test specifications.
This second edition cancels and replaces the first edition published in 2020. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) Mating conditions changed, see Figure 2, Figure 4, Figure 13, Figure 15, Figure 19 and Figure 21.
b) Voltage proof requirement added, 2 250 V DC, see 5.7.2.
c) Mechanical shock requirement added, see 5.7.6 (the requirement itself already was specified indirectly by Ed1 due to the specification of the test EP3 of Table 14 which is still identical to Ed1).
d) Styles added, 6P-M8CI and 6J-M8CI, see Table 1.

  • Standard
    48 pages
    English language
    sale 15% off

This part of IEC 61076-2 specifies circular connectors with a push-pull locking mechanism of a size derived from, and thus being compatible with M12 screw-locking connectors (free connectors with screw-locking according to IEC 61076‑2‑101, IEC 61076-2-109,
IEC 61076-2-111 or IEC 61076‑2‑113 are compatible with push‑pull fixed interfaces according
to this document) and with mating interfaces according to IEC 61076‑2‑101, IEC 61076-2-109,
IEC 61076-2-111 (except codings E in general and coding F for inner push-pull) or
IEC 61076-2-113.
A fixed connector with push-pull locking according to this document is intermateable with a
correspondingly coded free connector with M12 screw-locking according to any of the above
mentioned standards.
NOTE 1 M12 is the dimension of the thread of the screw-locking mechanism of circular connectors with M12 screwlocking.
NOTE 2 IEC 61076-2-012 defines another inner push-pull for fixed female connectors which is however not
compatible to the inner push-pull defined in this document. Annex C shows the different styles of female free
connectors to extend male free connectors.
This document covers both:
a) power connectors with current ratings up to 16 A and voltage ratings up to 630 V, typically
used for power supply and power applications in industrial premises, and
b) connectors for data and signal transmission with frequencies up to 500 MHz.
These connectors consist of both, fixed and free connectors, either rewirable or non-rewirable,
with M12 push-pull locking as explained above. Male connectors have round contacts from Ø
0,6 mm up to Ø 1,5 mm. In addition, the push-pull mechanisms consist of 2 different push-pull
designs:
c) An outer push-pull for male and female fixed connector, where the locking groove is placed
onto the outer cylindric surface of the housing. The outer push-pull for female fixed
connectors is made for 2 different types of male connectors. It has locking means for both
types on its outer surface.
NOTE 3 For design and dimensions see 5.3.2 and 5.3.3.
d) An inner push-pull for female fixed connectors and for male free connectors, where the
locking means are placed onto the inner cylindric surface of the housing.
NOTE 4 For design and dimensions see 5.3.4.
The different codings provided by IEC 61076-2 series detail specifications mentioned within this
document prevent the mating of accordingly coded male or female connectors to any other
similarly sized interfaces, covered by other standards and the cross-mating between the
different codings provided by any other IEC 61076-2 series detail specification mentioned within
this document.

  • Standard
    55 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of IEC 61076-2 describes the bayonet coupling interface of circular connectors that
are typically used for industrial process measurement and control. These connectors consist of
fixed and free connectors either rewireable or non-rewireable, with bayonet-coupling. These
connectors may have glass to metal seal inserts. They have male or female contacts and are
deemed to be intermateable with corresponding free connectors produced according to this
document. Male connectors have round contacts Ø 0,6 mm, Ø 0,76 mm, Ø 0,8 mm and
Ø 1,0 mm.
Different codings prevent the mating of these individually coded fixed connectors (and
consequently of individually coded free connectors deemed to couple with them) to other
interfaces and cross-mating between the different codings. However, the styles and interface
dimensions, except for the coupling mechanism, are as given in 4.3 of IEC 61076-2- 101:2012
and 4.3.1 of IEC 61076-2-109:2014.
The male type B12 circular connectors are interoperable with the female type B12 connector of
the same coding and ways. The female type B12 connectors are interoperable with the male
type B12 and M12 (threaded screw coupling) connector of the same coding and ways.
NOTE B12 relates to a bayonet coupling with tube dimensions compatible with a M12 thread. M12 is the dimension
of the thread of the screw-coupling mechanism of circular connectors covered by IEC 61076-2-101 and
IEC 61076-2-109, which provide the mating interface (connector insert level) to these connectors with bayonet
coupling.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61076-2-011:2021 describes the bayonet coupling interface of circular connectors that are typically used for industrial process measurement and control. These connectors consist of fixed and free connectors either rewireable or non-rewireable, with bayonet-coupling. These connectors may have glass to metal seal inserts. They have male or female contacts and are deemed to be intermateable with corresponding free connectors produced according to this document. Male connectors have round contacts Ø 0,6 mm, Ø 0,76 mm, Ø 0,8 mm and Ø 1,0 mm. Different codings prevent the mating of these individually coded fixed connectors (and consequently of individually coded free connectors deemed to couple with them) to other interfaces and cross-mating between the different codings. However, the styles and interface dimensions, except for the coupling mechanism, are as given in 4.3 of IEC 61076-2- 101:2012 and 4.3.1 of IEC 61076-2-109:2014. The male type B12 circular connectors are interoperable with the female type B12 connector of the same coding and ways. The female type B12 connectors are interoperable with the male type B12 and M12 (threaded screw coupling) connector of the same coding and ways.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61076-2-010:2021 specifies circular connectors with a push-pull locking mechanism of a size derived from, and thus being compatible with M12 screw-locking connectors (free connectors with screw-locking according to IEC 61076-2-101, IEC 61076-2-109, IEC 61076-2-111 or IEC 61076-2-113 are compatible with push‑pull fixed interfaces according to this document) and with mating interfaces according to IEC 61076-2-101, IEC 61076-2-109, IEC 61076-2-111 (except codings E in general and coding F for inner push-pull) or IEC 61076-2-113. A fixed connector with push-pull locking according to this document is intermateable with a correspondingly coded free connector with M12 screw-locking according to any of the above mentioned standards. M12 is the dimension of the thread of the screw-locking mechanism of circular connectors with M12 screw-locking. IEC 61076-2-012 defines another inner push-pull for fixed female connectors which is however not compatible to the inner push-pull defined in this document. Annex C shows the different styles of female free connectors to extend male free connectors. This document covers both: a) power connectors with current ratings up to 16 A and voltage ratings up to 630 V, typically used for power supply and power applications in industrial premises, and b) connectors for data and signal transmission with frequencies up to 500 MHz. These connectors consist of both, fixed and free connectors, either rewirable or non-rewirable, with M12 push-pull locking as explained above. Male connectors have round contacts from Ø 0,6 mm up to Ø 1,5 mm. In addition, the push-pull mechanisms consist of 2 different push-pull designs: c) An outer push-pull for male and female fixed connector, where the locking groove is placed onto the outer cylindric surface of the housing. The outer push-pull for female fixed connectors is made for 2 different types of male connectors. It has locking means for both types on its outer surface. For design and dimensions see 5.3.2 and 5.3.3. d) An inner push-pull for female fixed connectors and for male free connectors, where the locking means are placed onto the inner cylindric surface of the housing. For design and dimensions see 5.3.4. The different codings provided by IEC 61076-2 series detail specifications mentioned within this document prevent the mating of accordingly coded male or female connectors to any other similarly sized interfaces, covered by other standards and the cross-mating between the different codings provided by any other IEC 61076-2 series detail specification mentioned within this document.

  • Standard
    55 pages
    English language
    sale 10% off
    e-Library read for
    1 day