33.120.01 - Components and accessories in general
ICS 33.120.01 Details
Components and accessories in general
Bauteile und Zubehor fur Telekommunikationsgerate im allgemeinen
Composants et accessoires en general
Komponente in pribor na splošno
General Information
e-Library Subscription
Create subscription and get permanent access to documents within 33.120.01 - Components and accessories in general
Currently subscription includes documents marked with .We are working on making all documents available within the subscription.
This part of IEC 60966 is a detail specification that relates to semi-flexible cable assemblies composed of type 50-141 semi-flexible coaxial cables with polytetrafluoroethylene (PTFE) dielectric (IEC 61196-8-4) and connectors such as, type SMA(IEC 61169-15), type N (IEC 61169-16). It gives subfamily detail requirements and severities which shall be applied.
These cable assemblies are mainly used in the field of microwave and wireless equipment or other signal transmission equipment or units. The operating frequency is up to 18000 MHz.
The qualification will be conducted in accordance with IEC 60966-3. Once one variant obtain qualification approval, the other variant with same cable and connection type can obtain qualification approval by conducting tests whose results might depend on the variants.
Under capability approval, the qualification will be conducted on the relating CQCs (capability qualifying components) as defined in IEC 60966-3 and described in the CM(capability manual). Unless otherwise specified in the CM, only lot-by-lot tests from groups Ba and Eb will be conducted on delivered products, all other tests will be performed on CQCs as defined in IEC 60966-3 and described in the CM.
- Standard16 pagesEnglish languagesale 10% offe-Library read for1 day
This part of IEC 60966 is a detail specification that relates to semi-flexible cable assemblies composed of type 50-141 semi-flexible coaxial cables with polytetrafluoroethylene (PTFE) dielectric (IEC 61196-8-4) and connectors such as type 7-16 (IEC 61169-4), type 4,1-9,5 (IEC 61169-11), type S7-16 (IEC 61169-53) ,type 4,3-10 (IEC 61169-54). It gives subfamily detail requirements and severities which shall be applied.
These cable assemblies are mainly used in the field of mobile communication base station antenna system, terrestrial microwave communication and radar systems. The operating frequency is up to 6000 MHz.
The qualification will be conducted in accordance with IEC 60966-3. Once one variant obtain qualification approval, the other variant with same cable and connection type can obtain qualification approval by conducting tests whose results might depend on the variants.
Under capability approval, the qualification will be conducted on the relating CQCs (capability qualifying components) as defined in IEC 60966-3 and described in the CM(capability manual). Unless otherwise specified in the CM, only lot-by-lot tests from groups Ba and Eb will be conducted on delivered products, all other tests will be performed on CQCs as defined in IEC 60966-3 and described in the CM.
- Standard17 pagesEnglish languagesale 10% offe-Library read for1 day
This part of IEC 60966 is a detail specification that relates to semi-flexible cable assemblies composed of type 50-141 semi-flexible coaxial cables with polytetrafluoroethylene (PTFE) dielectric (IEC 61196-8-4) and connectors such as type 7-16 (IEC 61169-4), type 4,1-9,5 (IEC 61169-11), type S7-16 (IEC 61169-53) ,type 4,3-10 (IEC 61169-54). It gives subfamily detail requirements and severities which shall be applied. These cable assemblies are mainly used in the field of mobile communication base station antenna system, terrestrial microwave communication and radar systems. The operating frequency is up to 6000 MHz. The qualification will be conducted in accordance with IEC 60966-3. Once one variant obtain qualification approval, the other variant with same cable and connection type can obtain qualification approval by conducting tests whose results might depend on the variants. Under capability approval, the qualification will be conducted on the relating CQCs (capability qualifying components) as defined in IEC 60966-3 and described in the CM(capability manual). Unless otherwise specified in the CM, only lot-by-lot tests from groups Ba and Eb will be conducted on delivered products, all other tests will be performed on CQCs as defined in IEC 60966-3 and described in the CM.
- Standard17 pagesEnglish languagesale 10% offe-Library read for1 day
This part of IEC 60966 is a detail specification that relates to semi-flexible cable assemblies composed of type 50-141 semi-flexible coaxial cables with polytetrafluoroethylene (PTFE) dielectric (IEC 61196-8-4) and connectors such as, type SMA(IEC 61169-15), type N (IEC 61169-16). It gives subfamily detail requirements and severities which shall be applied. These cable assemblies are mainly used in the field of microwave and wireless equipment or other signal transmission equipment or units. The operating frequency is up to 18000 MHz. The qualification will be conducted in accordance with IEC 60966-3. Once one variant obtain qualification approval, the other variant with same cable and connection type can obtain qualification approval by conducting tests whose results might depend on the variants. Under capability approval, the qualification will be conducted on the relating CQCs (capability qualifying components) as defined in IEC 60966-3 and described in the CM(capability manual). Unless otherwise specified in the CM, only lot-by-lot tests from groups Ba and Eb will be conducted on delivered products, all other tests will be performed on CQCs as defined in IEC 60966-3 and described in the CM.
- Standard16 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60966-3-4:2023 is a detail specification that relates to semi-flexible cable assemblies composed of type 50-141 semi-flexible coaxial cables with polytetrafluoroethylene (PTFE) dielectric (IEC 61196-8-4) and connectors such as, type SMA (IEC 61169-15), type N (IEC 61169-16). It gives subfamily detail requirements and severities to be applied.
These cable assemblies are mainly used in the field of mobile communication base station antenna system, terrestrial microwave communication and radar systems. The operating frequency is up to 6 000 MHz
- Standard25 pagesEnglish and French languagesale 15% off
IEC 60966-3-3:2023 is a detail specification that relates to semi-flexible cable assemblies composed of type 50-141 semi-flexible coaxial cables with polytetrafluoroethylene (PTFE) dielectric (IEC 61196-8-4) and connectors such as, type SMA (IEC 61169-15), type N (IEC 61169-16). It gives subfamily detail requirements and severities to be applied. These cable assemblies are mainly used in the field of microwave and wireless equipment or other signal transmission equipment or units. The operating frequency is up to 18 000 MHz.
- Standard25 pagesEnglish and French languagesale 15% off
IEC 62037-8:2022 defines a radiated passive intermodulation (PIM) test to determine PIM levels generated by a device or object when it is exposed to RF radiation. This test can be conducted on any material or object and is not limited to devices designed to propagate RF signals. This test can be conducted as either a near field or far field test as defined by the test specification in an outdoor test site or in an anechoic test chamber.
- Standard14 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62037-7:2022 defines test methods for reverse measurement of passive intermodulation (PIM) in systems of RF components deployed in the field. Field PIM measurements can be conducted on RF systems terminated into low PIM loads or on antenna feed systems that broadcast the test signals into the environment.
- Standard14 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62037-8:2022 defines a radiated passive intermodulation (PIM) test to determine PIM levels generated by a device or object when it is exposed to RF radiation. This test can be conducted on any material or object and is not limited to devices designed to propagate RF signals. This test can be conducted as either a near field or far field test as defined by the test specification in an outdoor test site or in an anechoic test chamber.
- Standard22 pagesEnglish and French languagesale 15% off
IEC 62037-7:2022 defines test methods for reverse measurement of passive intermodulation (PIM) in systems of RF components deployed in the field. Field PIM measurements can be conducted on RF systems terminated into low PIM loads or on antenna feed systems that broadcast the test signals into the environment.
- Standard22 pagesEnglish and French languagesale 15% off
This standard describes the measurement of screening attenuation by the reverberation chamber measurement method, also called mode stirred chamber method. This standard is applicable to screening attenuation measurements of cable assemblies, cables, connectors, and passive microwave components, such as waveguides, phase shifters, diplexers/multiplexers, power dividers/combiners and etc. Modern electronic equipments have shown a demand for methods for testing screening attenuation performance of microwave components over their whole frequency range. Convenient measurement methods have existed for lower frequencies and components of regular shape. These measurement methods are described in IEC 62153 series standards. For much higher frequencies and for components of irregular shape, the reverberation chamber method should be used. Theoretically, the reverberation chamber method has no upper limit of the measurement frequency, but it is limited by the quality and sensitivity of the measurement system, and the lower limit of the measurement frequency is restricted by the size of the reverberation chamber.
- Standard22 pagesEnglish languagesale 10% offe-Library read for1 day
This part of IEC 60966 is a detail specification that relates to semi-rigid cable assemblies composed of type 50-9 semi-rigid coaxial cables with foamed polyethylene dielectric and connectors such as type 7-16 (IEC 61169-4), type 4.1-9.5 (IEC 61169-11), type N (IEC 61169-16),type S7-16 (IEC 61169-53) or type 4.3-10 (IEC 61169-54). This detail specification applies to the cable assemblies (jumper cables) for mobile communication, particular for the cable assemblies used between the main feeder and antennas or between the main feeder and equipment system or between remote radio heads and antennas. The operating frequency is up to 6 000 MHz.
- Standard17 pagesEnglish languagesale 10% offe-Library read for1 day
This part of IEC 60966 is a detail specification that relates to semi-rigid cable assemblies composed of type 50-12 low loss semi-rigid coaxial cables and connectors such as type 7-16 (IEC 61169-4), type 4.1-9.5 (IEC 61169-11), type N (IEC 61169-16), type S7-16 (IEC 61169-53) or type 4.3-10 (IEC 61169-54). This detail specification applies to the cable assemblies (jumper cables) for mobile communication, particularly for the cable assemblies used between the main feeder and antennas or between the main feeder and equipment system or between remote radio heads and antennas. The operating frequency is up to 6 000 MHz.
- Standard17 pagesEnglish languagesale 10% offe-Library read for1 day
This part of IEC 60966 is a detail specification that applies to cable assemblies with F-Quick connectors (see IEC 61169-47) and requires quad-shield screening class A++ (see IEC 61196-6-5). This detail specification applies to the cable assemblies for radio and TV receivers.
- Standard14 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61726:2022 describes the measurement of screening attenuation by the reverberation chamber measurement method, also called mode stirred chamber method.
This document is applicable to screening attenuation measurements of cable assemblies, cables, connectors, and passive microwave components, such as waveguides, phase shifters, diplexers/multiplexers, power dividers/combiners, etc.
This fourth edition cancels and replaces the third edition published in 2015. This edition includes the following significant technical changes with respect to the previous edition:
a. reworded Clause 1 "Scope";
b. replaced IEC TS 62153-4-1 by IEC 62153 (all parts) in Clause 2;
c. added the definition of screening attenuation in 3.1;
d. added Clause 4 "Principle of screening attenuation measurement";
e. added the descriptions of some test set-ups, such as frequency synthesizer, spectrum analyser, stepper motor, linking devices and the sampling system, etc. in Clause 5;
f. added Clause 6 "DUT";
g. reworded Clause 7 "Measurement procedure";
h. added Clause 8 "Caution notes";
i. added Clause 9 "Acceptance criterion";
j. added Clause 10 "Information to be given in the relevant specification".
- Standard38 pagesEnglish and French languagesale 15% off
IEC 60966-4-3:2022 is a detail specification that relates to semi-rigid cable assemblies composed of type 50-12 low loss semi-rigid coaxial cables and connectors such as type 7-16 (IEC 61169-4), type 4.1-9.5 (IEC 61169-11), type N (IEC 61169-16), type S7-16 (IEC 61169-53) or type 4.3-10 (IEC 61169-54).
This detail specification applies to the cable assemblies (jumper cables) for mobile communication, particularly for the cable assemblies used between the main feeder and antennas or between the main feeder and equipment system or between remote radio heads and antennas. The operating frequency is up to 6 000 MHz.
- Standard26 pagesEnglish and French languagesale 15% off
IEC 60966-4-2:2022 is a detail specification that relates to semi-rigid cable assemblies composed of type 50-9 semi-rigid coaxial cables with foamed polyethylene dielectric and connectors such as type 7-16 (IEC 61169-4), type 4.1-9.5 (IEC 61169-11), type N (IEC 61169-16),type S7-16 (IEC 61169-53) or type 4.3-10 (IEC 61169-54).
This detail specification applies to the cable assemblies (jumper cables) for mobile communication, particular for the cable assemblies used between the main feeder and antennas or between the main feeder and equipment system or between remote radio heads and antennas. The operating frequency is up to 6 000 MHz.
- Standard26 pagesEnglish and French languagesale 15% off
IEC 60966-2-8:2022 is a detail specification that applies to cable assemblies with F-Quick connectors (see IEC 61169-47) and requires quad-shield screening class A++ (see IEC 61196-6-5). This detail specification applies to the cable assemblies for radio and TV receivers.
This detail specification gives subfamily requirements and severities which shall be applied.
- Standard21 pagesEnglish and French languagesale 15% off
Specifies the main dimensions of coil formers for transformers and inductors, using a square stack of the laminations inserted in the coil formers.
- Standard10 pagesEnglish languagesale 15% off
- Draft12 pagesEnglish languagesale 10% offe-Library read for1 day
- Draft12 pagesEnglish languagesale 10% offe-Library read for1 day
This standard refers to HD 608 S1:1992, Generic specification for symmetrical pair/quad or multicore cables for digital communications. It covers individually screened pair(s) or quad(s) in cables for work area wiring. The cables shall be provided with a common overall screen. These cables are suitable for different communication systems to which reference is made in detail specifications. The cables covered by this specification are intended to operate with voltages and currents normally adopted for communication systems. These cables shall not be connected to low impedance sources, for example, the public mains electricity supply. The cables specified in this standard shall meet the requirements of the Generic Specification. This sectional specification may be supplemented with specific specifications given additional information if required by a particular application (e.g. regarding safety and reliability conditions)
- Standard12 pagesEnglish languagesale 10% offe-Library read for1 day
This standard refers to HD 608 S1:1992, Generic specification for symmetrical pair/quad or multicore cables for digital communications. It covers individually screened or unscreened pair(s) or quad(s) in cables for vertical shafts or vertically between floors (riser backbone cables) or in horizontal between buildings (campus backbone cables). In the same cable both screened and unscreened elements may be used. When installed vertically extra strength requirements may be applicable and are defined in the detail specifications. The cables shall be provided with a common overall screen. These cables are suitable for different communication systems to which reference is made in the detail specifications. The cables covered by this specification are intended to operate with voltages and currents normally adopted for communication systems. These cables shall not be connected to low impedance sources, for example, the public mains electricity supply
- Standard12 pagesEnglish languagesale 10% offe-Library read for1 day
This standard refers to HD 608 S1:1992, Generic specification for symmetrical pair/quad or multicore cables for digital communications. It covers individually screened pair(s) or quad(s) in cables for horizontal floor wiring. In the same cable both screened and unscreened elements may be used. The cables shall be provided with a common overall screen. These cables are suitable for different communication systems to which reference is made in the detail specifications. The cables covered by this specification are intended to operate with voltages and currents normally adopted for communication systems. These cables shall not be connected to low impedance sources, for example, the public mains electricity supply
- Standard12 pagesEnglish languagesale 10% offe-Library read for1 day
This is a consolidated reprint of 1988 consisting of IEC 60096-2 (1961) and supplements 60096-2A (1965), 60096-2B (1966), 60096-2C (1976) and 60096-2D (1986).
The contents of the corrigenda of April 1993 and August 1997 have been included in this copy.
- Standard1 pageEnglish and French languagesale 15% off
- Standard1 pageEnglish and French languagesale 15% off