SIST EN 61169-38:2009
(Main)Radio-frequency connectors - Part 38: Sectional specification - Radio frequency coaxial connectors model, slide-in (rack and panel applications) - Characteristic impedance 50 O (type TMA) - 50 O applications (IEC 61169-38:2008)
Radio-frequency connectors - Part 38: Sectional specification - Radio frequency coaxial connectors model, slide-in (rack and panel applications) - Characteristic impedance 50 O (type TMA) - 50 O applications (IEC 61169-38:2008)
This part of 61169, which is a sectional specification, provides information and rules for the preparation of detail specifications for series TMA r.f. connectors together with the pro forma blank detail specification. Series TMA connectors have a characteristic impedance of 50 Ω and are normally used with R.F cables or with microstrip in microwave fields that has a blind-entry and middle low-power. The connectors are usable up to a frequency of at least 6 GHz. This specification also prescribes mating face dimensions for general purpose connectors, dimensional details of standard test connectors grade 0, gauging information and tests selected from QC 220000 (IEC 61169-1), applicable to all detail specifications relating to series TMA connectors. This specification indicates the recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H.
Hochfrequenz-Steckverbinder - Teil 38: Rahmenspezifikation - Koaxiale Hochfrequenzsteckverbinder mit Einschubkupplung (Einschubausführung) - Wellenwiderstand 50 O (Typ TMA) - 50-O-Anwendungen (IEC 61169-38:2008)
Connecteurs pour fréquences radioélectriques - Partie 38: Spécification intermédiaire - Connecteurs coaxiaux pour fréquences radioélectriques avec accouplements de type glis (applications de panneau et fond de panier ) - Impédance caractéristique 50 O (type TMA) - Applications à 50 O (CEI 61169-38:2008)
La CEI 61169-38:2008 est une spécification intermédiaire (SS: Sectional Specification). Elle fournit des informations et des règles pour la préparation de spécifications particulières (DS: Detail Specification) pour les connecteurs RF de type TMA en série et le modèle pro-forma de la spécification particulière cadre. Les connecteurs de type TMA en série ont une impédance caractéristique de 50 Ω et sont normalement utilisés avec des câbles RF ou avec un micro-ruban dans des champs hyperfréquences ayant une entrée aveugle et une puissance basse moyenne. Les connecteurs peuvent être utilisés jusqu'à une fréquence pouvant atteindre au moins 6 GHz. La présente spécification prescrit également les dimensions des faces d'accouplement pour des connecteurs d'usage général, des informations détaillées sur les dimensions de connecteurs d'essais normalisés (catégorie 0), des informations sur les calibres et des essais choisis dans la norme QC 220000 (CEI 61169-1), applicables à toutes les spécifications particulières portant sur des connecteurs de type TMA en série. La présente spécification indique les caractéristiques de performance recommandées à prendre en considération pour rédiger une spécification particulière et elle porte sur des programmes d'essais et des exigences d'inspection pour les niveaux d'assurance M et H.
Radiofrekvenčni konektorji - 38. del: Področna specifikacija - Model radiofrekvenčnih koaksialnih zdrsnih konektorjev (za stojalo in ploščo) - Karakteristična impedanca 50 ohmov (tip TMA) - 50-ohmske aplikacije (IEC 61169-38:2008)
General Information
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 61169-38:2009
01-maj-2009
5DGLRIUHNYHQþQLNRQHNWRUMLGHO3RGURþQDVSHFLILNDFLMD0RGHO
UDGLRIUHNYHQþQLKNRDNVLDOQLK]GUVQLKNRQHNWRUMHY]DVWRMDORLQSORãþR
.DUDNWHULVWLþQDLPSHGDQFDRKPRYWLS70$RKPVNHDSOLNDFLMH,(&
Radio-frequency connectors - Part 38: Sectional specification - Radio frequency coaxial
connectors model, slide-in (rack and panel applications) - Characteristic impedance 50 O
(type TMA) - 50 O applications (IEC 61169-38:2008)
Hochfrequenz-Steckverbinder - Teil 38: Rahmenspezifikation - Koaxiale
Hochfrequenzsteckverbinder mit Einschubkupplung (Einschubausführung) -
Wellenwiderstand 50 O (Typ TMA) - 50-O-Anwendungen (IEC 61169-38:2008)
Connecteurs pour fréquences radioélectriques - Partie 38: Spécification intermédiaire -
Connecteurs coaxiaux pour fréquences radioélectriques avec accouplements de type
glis (applications de panneau et fond de panier ) - Impédance caractéristique 50 O
(type TMA) - Applications à 50 O (CEI 61169-38:2008)
Ta slovenski standard je istoveten z: EN 61169-38:2009
ICS:
33.120.30 5DGLRIUHNYHQþQLNRQHNWRUML R.F. connectors
5)
SIST EN 61169-38:2009 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST EN 61169-38:2009
---------------------- Page: 2 ----------------------
SIST EN 61169-38:2009
EUROPEAN STANDARD
EN 61169-38
NORME EUROPÉENNE
March 2009
EUROPÄISCHE NORM
ICS 33.120.20
English version
Radio-frequency connectors -
Part 38: Sectional specification -
Radio frequency coaxial connectors model, slide-in
(rack and panel applications) -
Characteristic impedance 50 Ω (type TMA) -
50 Ω applications
(IEC 61169-38:2008)
Connecteurs pour fréquences radioélectriques - Hochfrequenz-Steckverbinder -
Partie 38: Spécification intermédiaire - Teil 38: Rahmenspezifikation -
Connecteurs coaxiaux pour fréquences Koaxiale Hochfrequenzsteckverbinder mit
radioélectriques avec accouplements de type glis Einschubkupplung (Einschubausführung) -
(applications de "panneau" et "fond de panier") - Wellenwiderstand 50 Ω (Typ TMA) -
Impédance caractéristique 50 Ω (type TMA) - 50-Ω-Anwendungen
Applications à 50 Ω
(IEC 61169-38:2008)
(CEI 61169-38:2008)
This European Standard was approved by CENELEC on 2008-12-01. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the
Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: avenue Marnix 17, B - 1000 Brussels
© 2009 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61169-38:2009 E
---------------------- Page: 3 ----------------------
SIST EN 61169-38:2009
EN 61169-38:2009 – 2 –
Foreword
The text of document 46F/75/CDV, future edition 1 of IEC 61169-38, prepared by SC 46F, R.F. and
microwave passive components, of IEC TC 46, Cables, wires, waveguides, R.F. connectors, R.F. and
microwave passive components and accessories, was submitted to the IEC-CENELEC parallel vote and
was approved by CENELEC as EN 61169-38 on 2008-12-01.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2009-09-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2011-12-01
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of the International Standard IEC 61169-38:2008 was approved by CENELEC as a European
Standard without any modification.
__________
---------------------- Page: 4 ----------------------
SIST EN 61169-38:2009
– 3 – EN 61169-38:2009
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.
Publication Year Title EN/HD Year
IEC 61169-1 1992 Radio-frequency connectors - EN 61169-1 1994
Part 1: Generic specification - General
requirements and measuring methods
1)
IEC QC 001005 - IEC Quality assessment system for - -
electronic components (IECQ) - Register of
films, products and services approved under
the IECQ system, including ISO 9000
1)
Undated reference.
---------------------- Page: 5 ----------------------
SIST EN 61169-38:2009
---------------------- Page: 6 ----------------------
SIST EN 61169-38:2009
IEC 61169-38
Edition 1.0 2008-11
INTERNATIONAL
STANDARD
Radio-frequency connectors –
Part 38: Sectional specification – Radio frequency coaxial connectors model,
slide-in (rack and panel applications) – Characteristic impedance 50 Ω (type
TMA) – 50 Ω applications
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
PRICE CODE
U
ICS 33.120.20 ISBN 2-8318-1008-7
® Registered trademark of the International Electrotechnical Commission
---------------------- Page: 7 ----------------------
SIST EN 61169-38:2009
– 2 – 61169-38 © IEC:2008(E)
CONTENTS
FOREWORD.4
1 Scope.6
2 Normative references .6
3 Mating face and gauge information.7
3.1 Dimensions – General connectors – Grade 2.7
3.1.1 Connector with pin centre contact (see Figure 1) .7
3.1.2 Connectors with socket-centre contact (see Figure 2).8
3.2 Gauges .9
3.2.1 Connectors with pin-centre contact.9
3.2.2 Connectors with socket-centre contact .10
3.3 Dimensions – standard test connectors – Grade 0.11
3.3.1 Connector with pin-centre contact (see Figure 5).11
3.3.2 Connector with socket-centre contact (see Figure 6) .12
3.4 General requirements for connector mounting in modules and on panels.14
3.4.1 Radial misalignment .14
3.4.2 Axial misalignment .14
4 Quality assessment procedure.15
4.1 General .15
4.2 Rating and characteristics ( see Clause 6 of IEC 61169-1/QC220000) .15
4.3 Test schedule and inspection requirements .18
4.3.1 Acceptance tests (see Table 8).18
4.3.2 Periodic tests (see Table 9) .19
4.4 Procedures.20
4.4.1 Quality conformance inspection .20
4.4.2 Qualification approval and its maintenance.20
5 Instructions for preparation of detail specifications .20
5.1 General .20
5.2 Identification of the detail specification .21
5.3 Identification of the component.21
5.4 Performance.21
5.5 Marking, ordering information and related matters .21
5.6 Selection of tests, test conditions and severities.22
5.7 Blank detail specification pro-forma for type TMA connector.23
Figure 1 – Connector with pin-centre contact (for dimensions, see Table 1).7
Figure 2 – Connector with socket-centre contact (for dimensions, see Table 2) .8
Figure 3 – Gauge for outer contact of pin connector (for dimensions, see Table 3) .9
Figure 4 – Gauge pin for socket-centre contact (for dimensions, see Table 4).10
Figure 5 – Standard test connector with pin-centre contact (for dimensions, see Table 5).11
Figure 6 – Standard test connector with socket-centre contact (for dimensions, see
Table 6) .12
Figure 7 – The sketch map of connector radial misalignment .14
Figure 8 – The sketch map of rigidly mounted and float-mounted connector.14
Table 1 – Dimensions of connector with pin-centre contact .7
---------------------- Page: 8 ----------------------
SIST EN 61169-38:2009
61169-38 © IEC:2008(E) – 3 –
Table 2 – Dimensions of connector with socket-centre contact.8
Table 3 – Dimensions of gauge for outer contact of pin connector .9
Table 4 – Dimensions of gauge pin for socket-center contact.10
Table 5 – Dimensions of standard test connector with pin-centre contact.11
Table 6 – Dimensions of standard test connector with socket-centre contact .13
Table 7 – Rating and characteristics .15
Table 8 – Acceptance tests.18
Table 9 – Periodic tests .19
---------------------- Page: 9 ----------------------
SIST EN 61169-38:2009
– 4 – 61169-38 © IEC:2008(E)
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
RADIO-FREQUENCY CONNECTORS –
Part 38: Sectional specification –
Radio frequency coaxial connectors model,
slide-in (rack and panel applications) –
Characteristic impedance 50 Ω (type TMA) –
50 Ω applications
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61169-38 has been prepared by subcommittee 46F: RF and
microwave passive components, of IEC technical committee 46: Cables, wires, waveguides,
R.F. connectors, R.F. and microwave passive components and accessories.
This standard cancels and replaces IEC/PAS 61169-38 published in 2007.
The text of this standard is based on the following documents:
CDV Report on voting
46F/75/CDV 46F/90/RVC
---------------------- Page: 10 ----------------------
SIST EN 61169-38:2009
61169-38 © IEC:2008(E) – 5 –
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
A list of all parts of the IEC 61169 series, under the general title: Radio-frequency connectors,
can be found on the IEC website.
The committee has decided that the contents of this publication will remain unchanged until
the maintenance result date indicated on the IEC web site under "http://webstore.iec.ch" in
the data related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
A bilingual version of this publication may be issued at a later date.
---------------------- Page: 11 ----------------------
SIST EN 61169-38:2009
– 6 – 61169-38 © IEC:2008(E)
RADIO-FREQUENCY CONNECTORS –
Part 38: Sectional specification –
Radio frequency coaxial connectors model,
slide-in (rack and panel applications) –
Characteristic impedance 50 Ω (type TMA) –
50 Ω applications
1 Scope
This part of 61169, which is a sectional specification, provides information and rules for the
preparation of detail specifications for series TMA r.f. connectors together with the pro forma
blank detail specification.
Series TMA connectors have a characteristic impedance of 50 Ω and are normally used with
R.F cables or with microstrip in microwave fields that has a blind-entry and middle low-power.
The connectors are usable up to a frequency of at least 6 GHz.
This specification also prescribes mating face dimensions for general purpose connectors,
dimensional details of standard test connectors grade 0, gauging information and tests
selected from QC 220000 (IEC 61169-1), applicable to all detail specifications relating to
series TMA connectors.
This specification indicates the recommended performance characteristics to be considered
when writing a detail specification and it covers test schedules and inspection requirements
for assessment levels M and H.
2 Normative references
The following referenced documents are indispensable for the application of this document.
For dated references, only the edition cited applies. For undated references, the latest edition
of the referenced document (including any amendments) applies.
IEC 61169-1:1992, Radio-frequency connectors – Part 1: Generic specification – General
requirements and measuring methods
IEC QC 001005, Register of firms, products and services approved under the IECQ system,
including ISO 9000
---------------------- Page: 12 ----------------------
SIST EN 61169-38:2009
61169-38 © IEC:2008(E) – 7 –
3 Mating face and gauge information
3.0 General
Metric dimensions are original dimensions.
All undimensioned pictorial configurations are for reference purposes only.
3.1 Dimensions – General connectors – Grade 2
3.1.1 Connector with pin centre contact (see Figure 1)
g
Note 3
h
i
Note 2
1° ∼ 4°
55° ∼ 65°
Note 1
j
k
l
IEC 1789/08
Note 1
Figure 1 – Connector with pin-centre contact (for dimensions, see Table 1)
Table 1 – Dimensions of connector with pin-centre contact
mm in
Ref. Notes
min. max. min. max.
a — 0,64 — 0,025 Diameter
b 1,32 1,37 0,052 0,054 Diameter
c 2,06 2,21 0,081 0,087 Diameter
d 4,83 — 0,190 — Diameter
e — — — — 2/ Diameter
f 8,00 8,05 0,315 0,317 Diameter
g 8,60 — 0,339 —
h 0,08 1,02 0,003 0,040
i 0,15 — 0,006 —
j 1,96 3,05 0,078 —
k 5,33 5,84 0,210 0,230
l 5,28 5,79 0,208 0,228
NOTE 1 Mechanical and electrical reference plane.
NOTE 2 MSlotted and flared to meet electrical and mechanical requirements.
NOTE 3 MDesign and location of the sealing feature is optional but ensures the environmental performance
requirements are met.
e
d
f
b
c
---------------------- Page: 13 ----------------------
SIST EN 61169-38:2009
– 8 – 61169-38 © IEC:2008(E)
3.1.2 Connectors with socket-centre contact (see Figure 2)
v
w
x
35° ∼ 40°
Note 3
y
Note 2
aa
z
Note 1
IEC 1790/08
Figure 2 – Connector with socket-centre contact (for dimensions, see Table 2)
Table 2 – Dimensions of connector with socket-centre contact
mm in
Ref. Notes
min. max. min. max.
o — — — — 2/ Diameter
p 2,06 2,21 0,081 0,087 Diameter
q — 4,72 — 0,186 Diameter
r — 6,50 — 0,256 3/ Diameter
s 8,10 8,15 0,319 0,321 Diameter
t 10,00 10,15 0,394 0,400 Diameter
u 12,3 12,4 0,484 0,488 Diameter
v 4,78 5,28 0,188 0,208
w 4,72 5,23 0,186 0,206
x 4,95 — 0,195 —
y — 0,15 — 0,006
z 8,31 8,51 0,327 0,335
aa — — — — 4
NOTE 1 Mechanical and electrical reference plane.
NOTE 2 Slotted and closed to meet electrical and mechanical requirements.
NOTE 3 Applies only when dielectric extends beyond reference plane.
NOTE 4 Radius
o
p
q
r
s
t
u
---------------------- Page: 14 ----------------------
SIST EN 61169-38:2009
61169-38 © IEC:2008(E) – 9 –
3.2 Gauges
3.2.1 Connectors with pin-centre contact
3.2.1.1 Gauge for outer contact of pin connector (see Figure 3)
z
35° ∼ 40°
(aa)
IEC 1791/08
Figure 3 – Gauge for outer contact of pin connector (for dimensions, see Table 3)
Table 3 – Dimensions of gauge for outer contact of pin connector
Gauge B
(for measurement of gauge retention
Gauge A
force for outer conductor) Notes
(for sizing purposes)
Mass of gauge(weight): 225 g ± 5 g
mm in mm in
Ref.
min. max. min. max. min. max. min. max.
s 8,08 8,10 0,318 0,319 8,15 8,18 0,321 0,322 Diameter
t 10,00 10,15 0,394 0,400 10,00 10,15 0,394 0,400 Diameter
u 12,4 — 0,488 — 12,4 — 0,488 — Diameter
z 8,41 8,46 0,331 0,333 8,36 8,41 0,329 0,331 Diameter
aa 0,8 0,031 0,8 0,031 2/ Radius
NOTE 1 Material: steel, polished, surface roughness: Ra ≤ 0,4 µm (16 µin).
NOTE 2 Parentheses indicate the reference size for size.
3.2.1.2 Test sequence
Gauge A shall be placed over the outer electrical contact of the connector once. This is a
sizing operation and should only be carried out when the insulator is removed from the
connector.
After this, gauge B shall be placed over the outer contact in a vertical position. The gauge
shall be retained. This test can also be carried out on connectors when the insulator is not
removed.
u
s
t
---------------------- Page: 15 ----------------------
SIST EN 61169-38:2009
– 10 – 61169-38 © IEC:2008(E)
3.2.2 Connectors with socket-centre contact
3.2.2.1 Gauge pin for socket-centre contact (see Figure 4)
4 mm max.
(0,157 in max.)
3,17 mm min.
(0,125 in min.)
IEC 1792/08
Figure 4 – Gauge pin for socket-centre contact (for dimensions, see Table 4)
Table 4 – Dimensions of gauge pin for socket-center contact
Gauge D
Gauge C
(for measurement of gauge retention
Note
force for inner conductor)
(for sizing purpose)
Mass (weight) of gauge: 57 g ± 1 g
mm in mm in
Ref.
min. max. min. max. min. max. min. max.
b
1,372 1,377 0,054 0 0,0542 1,308 1,321 0,0515 0,052 0 Diameter
Material: steel, polished , surface roughness: Ra ≤ 0,4 µm (16 µin).
3.2.2.2 Test sequence
Test pin gauge C shall be inserted into the centre contact three times with a minimum
distance of 3,17 mm (0,125 in). This is a sizing operation and should only be carried out when
the socket-centre contact is removed from the connector.
After this, gauge D shall be inserted and held in the vertical position. The gauge shall be
retained. This test can also be carried out on connectors when the socket-centre contact is
not removed.
b
---------------------- Page: 16 ----------------------
SIST EN 61169-38:2009
61169-38 © IEC:2008(E) – 11 –
3.3 Dimensions – standard test connectors – Grade 0
3.3.1 Connector with pin-centre contact (see Figure 5)
∅0,01 mm
A
∅0,0005 in
∅0,1 mm
∅0,1 mm
A g
A
∅0,004 in
∅0,004 in
i
Note 3
Note 2
j
A
ab
∅0,05 mm
k
A
∅0,002 in
l
Note 4 Note 5
Note 1
B
ac
1° ∼ 3°
55° ∼ 65° ∅0,05 mm
A
∅0,002 in
Note 1
IEC 1793/08
Figure 5 – Standard test connector with pin-centre contact
(for dimensions, see Table 5)
Table 5 – Dimensions of standard test connector with pin-centre contact
mm in
Ref. Notes
min. max. min. max.
a — 0,64 — 0,025 Diameter
b 1,35 1,37 0,053 0 0,054 1 Diameter
c 2,140 nom. 0,084 2 nom. 2/ Diameter
d 4,88 4,93 0,192 0,194 Diameter
f 8,06 8,09 0,317 5 0,318 5 3/ Diameter
g 8,60 — 0,339 —
i 0,15 0,30 0,006 0,012
j 3,66 3,98 0,144 0,157
k 5,31 5,38 0,209 0,212
l 5,38 5,54 0,212 0,218
m 6,99 7,01 0,275 2 0,276 0 2/ Diameter
n1 6,60 6,65 0,260 0,262 Diameter
n2 6,72 6,74 0,264 5 0,265 5 Diameter
ab 0,1 0,3 0,004 0,012 Radius
ac — 0,13 — 0,005 Radius
NOTE 1 Mechanical and electrical reference plane.
NOTE 2 These diameters are for polytetrafluorethylene (PTFE) insulation with dielectric constant 2,02.
Characteristic impedance of transmission line determined by diameters m and c is 50 Ω ± 0,2 Ω.
NOTE 3 Before slotting. Six slots 60 º ± 1º apart, 0,36 mm to 0,41 mm( 0,014 in to 0,016 in) wide, 5,84 mm to
6,10 mm (0,230 in to 0,240 in) deep. After slotting and flaring, the inner diameter of outer contact should be
6,718 mm to 6,744 mm (0,264 5 in to 0,265 5 in) when inserted into ring gauge with inner diameter 8,125 mm to
8,131 mm ( 0,3199 in to 0,320,1 in).
NOTE 4 If concentric, 0,05 mm (0,002 in) nominal radial air gap when inserted into ring gauge with inner diameter
8,125 mm to 8,131 mm (0,319 9 in to 0,320 1 in).
NOTE 5 Zero air gap.
f
n2
n1
d
a
b c
c
m
---------------------- Page: 17 ----------------------
SIST EN 61169-38:2009
– 12 – 61169-38 © IEC:2008(E)
3.3.2 Connector with socket-centre contact (see Figure 6)
∅0,01 mm
C
v
∅0,0005 in
w
Note 2
bd
35° ∼ 40°
Note 4
C
∅0,1 mm
C
∅0,004 in
∅0,08 mm
y C
∅0,003 in
Note 4
Note 5 be ∅0,08 mm
Note 6 C
∅0,003 in
z
(aa)
Note 1
bj
Note 3
bk
D
60° ± 30′
Note 3
bm
∅0,05 mm
D
bn
∅0,002 in
x
IEC 1794/08
Figure 6 – Standard test connector with socket-centre contact
(for dimensions, see Table 6)
bc
bb
p
p
o
bf q
bh
r
s
t
u
---------------------- Page: 18 ----------------------
SIST EN 61169-38:2009
61169-38 © IEC:2008(E) – 13 –
Table 6 – Dimensions of standard test connector with socket-centre contact
mm in
Ref. Notes
min max min max
o 1,52 1,63 0,060 0,064 Diameter
p 2,140 nom 0,084 2 nom 2/ Diameter
q 4,67 4,72 0,184 0,186 Diameter
r 6,58 6,68 0,259 0,263 Diameter
s 8,10 8,15 0,319 0,321 Diameter
t 10,00 10,15 0,394 0,400 Diameter
u 12,3 12,4 0,484 0,488 Diameter
v 5,08 5,23 0,200 0,206
w 5,21 5,28 0,205 0,208
x 5,21 — 0,205 —
y 0,0 0,15 0,00 0,006 6
z 8,36 8,46 0,329 0,333
aa 0,8 0,031 7/ Diameter
bb 6,71 6,76 0,264 0,266 Diameter
bc 6,99 7,01 0,275 2 0,276 0 2/ Diameter
bd — 0,1 — 0,004 Radius
be 0,79 0,84 0,031 0,033
bf 1,356 1,361 0,053 4 0,053 6 3/ Diameter
bh 2,16 2,18 0,084 9 0,085 9 3/ Diameter
bj 6,05 6,10 0,238 0,240
bk 4,62 4,88 0,182 0,192
bm 0,05 0,2 0,002 0,008
bn 0,38 0,89 0,015 0,035
NOTE 1 Mechanical and electrical reference plane.
NOTE 2 These diameters are for polyterafluorethylene(PTFE) insulation with dielectric constant 2,02.
Characteristic impedance of transmission line determined by diameters p and bc is 50 Ω ± 0,2 Ω.
NOTE 3 Four slots 0,18 mm to 0,23 mm (0,007 in to 0,009 in ) wide ; 90°30' to 89°30' apart. Diameter y with
1,356 mm (0,0534 in) min: 1,361 mm (0,0536 in) max. pin gauge inserted after slotting and closing.
NOTE 4 If concentric 0,02 mm (0,0008 in) radial air gap when mated with 1,359 mm (0,053 5 in) diameter pin.
NOTE 5 Zero air gap.
NOTE 6 Insulator is flush or protruding.
NOTE 7 Parentheses indicate the reference size for size.
---------------------- Page: 19 ----------------------
SIST EN 61169-38:2009
– 14 – 61169-38 © IEC:2008(E)
3.4 General requirements for connector mounting in modules and on panels
3.4.1 Radial misalignment
The radial misalignment between engaging connectors refers to the coaxiality error A
(see Figure 7) between a connector with socket-centre contact and a connector with pin
centre contact at the beginning and during the engagement.
At the beginning of the engagement, the radial misalignment of rigidly mounted connector and
float-mounted connector shall no more than 0,51 mm.
IEC 1795/08
Figure 7 – The sketch map of connector radial misalignment
3.4.2 Axial misalignment
For rigidly mounted connector and float-mounted connector, the float mounting allows a total
of 1,52 mm (0,060 in) axial travel. The mounting arrangements should, however, ensure a
minimum length of travel of 0,26 mm (0,010 in) [0,76 mm (0,030 in) preferred ] to ensure that
full length of engagement is maintained under operational conditions (see Figure 8).
0,25 mm min.
(1,52 mm axial travel)
Mechanical and electrical reference plane
Spring mechanism
IEC 1796/08
Figure 8 – The sketch map of rigidly mounted and float-mounted connector
A
---------------------- Page: 20 ----------------------
SIST EN 61169-38:2009
61169-38 © IEC:2008(E) – 15 –
4 Quality assessment procedure
4.1 General
The following clauses provide recommended rating, performance and test conditions to be
considered when writing a detail specification. They also provide an appropriate schedule of
tests with minimum levels of conformance inspection sampling, together with the proforma
blank detail specifi
...
Questions, Comments and Discussion