Primary batteries - Part 1: General (IEC 60086-1:2011)

This part of IEC 60086 is intended to standardize primary batteries with respect to dimensions, nomenclature, terminal configurations, markings, test methods, typical performance, safety and environmental aspects.
As a primary battery classification tool, electrochemical systems are also standardized with respect to system letter, electrodes, electrolyte, nominal and maximum open circuit voltage.
NOTE The requirements justifying the inclusion or the ongoing retention of batteries in the IEC 60086 series are given in Annex A.
The object of IEC 60086-1 is to benefit primary battery users, device designers and battery manufacturers by ensuring that batteries from different manufacturers are interchangeable  according to standard form, fit and function. Furthermore, to ensure compliance with the above, this part specifies standard test methods for testing primary cells and batteries.

Primärbatterien - Teil 1: Allgemeines (IEC 60086-1:2011)

Piles primaires - Partie 1: Généralités (CEI 60086-1:2011)

La CEI 60086-1:2011 est destinée à normaliser les piles électriques en ce qui concerne les points suivants: dimensions, nomenclature, configurations des bornes, marquages, méthodes d'essai, caractéristiques, types de fonctionnement, sécurité et aspects environnementaux. L'objectif de la CEI 60086-1 est d'assurer aux utilisateurs, aux concepteurs d'appareils et aux fabricants de piles que les piles de différents fabricants sont interchangeables de par leur forme, leur montage et leur fonction. Les principales modifications techniques par rapport à l'édition précédente sont:
- la clarification des dispositifs de contrôle de l'humidité pour soumettre à l'essai différents types de piles;
- la modification des lignes directrices relatives à la normalisation pour permettre la normalisation des systèmes électrochimiques;
- la normalisation des systèmes électrochimiques lithium-chlorure de sulfuryle (LiSO2Cl2) et lithium-dioxyde de soufre (LiSO2).

Primarne baterije - 1. del: Splošno (IEC 60086-1:2011)

Ta del IEC 60068 je namenjen za standardizacijo primarnih baterij, kar zadeva dimenzije, nomenklaturo, konfiguracije terminalov, oznake, preskusne metode, tipične lastnosti, varnostne in okoljske vidike.
Kot glavno orodje za klasifikacijo baterij so elektrokemični sistemi standardizirani tudi glede na sistemsko črko, elektrode, elektrolite, nominalno in najvišjo napetost odprtega vezja.
OPOMBA: Zahteve, ki utemeljujejo vključitev ali tekoče zadržanje baterij v seriji IEC 60086, so podane v dodatku A.
Cilj IEC 60086-1 je korist za uporabnike primarnih baterij, snovalce naprav in proizvajalce baterij, z zagotavljanjem, da so baterije različnih proizvajalcev medsebojno zamenljive glede na standardno obliko, prileganje in funkcijo. Nadalje, da se zagotovi skladnost z zgoraj navedenim, ta del opredeljuje standardne preskusne metode za preskušanje primarnih celic in baterij.

General Information

Status
Withdrawn
Publication Date
11-Apr-2011
Withdrawal Date
17-Sep-2018
Technical Committee
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
18-Sep-2018
Due Date
11-Oct-2018
Completion Date
18-Sep-2018

Relations

Buy Standard

Standard
EN 60086-1:2011
English language
52 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 60086-1:2011
01-maj-2011
1DGRPHãþD
SIST EN 60086-1:2007
Primarne baterije - 1. del: Splošno (IEC 60086-1:2011)
Primary batteries - Part 1: General (IEC 60086-1:2011)
Primärbatterien - Teil 1: Allgemeines (IEC 60086-1:2011)
Piles primaires - Partie 1: Généralités (CEI 60086-1:2011)
Ta slovenski standard je istoveten z: EN 60086-1:2011
ICS:
29.220.10 3ULPDUQLþOHQLLQEDWHULMH Primary cells and batteries
SIST EN 60086-1:2011 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 60086-1:2011

---------------------- Page: 2 ----------------------

SIST EN 60086-1:2011

EUROPEAN STANDARD
EN 60086-1

NORME EUROPÉENNE
March 2011
EUROPÄISCHE NORM

ICS 29.220.10 Supersedes EN 60086-1:2007


English version


Primary batteries -
Part 1: General
(IEC 60086-1:2011)


Piles primaires -  Primärbatterien -
Partie 1: Généralités Teil 1: Allgemeines
(CEI 60086-1:2011) (IEC 60086-1:2011)




This European Standard was approved by CENELEC on 2011-03-24. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
Spain, Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Management Centre: Avenue Marnix 17, B - 1000 Brussels


© 2011 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 60086-1:2011 E

---------------------- Page: 3 ----------------------

SIST EN 60086-1:2011
EN 60086-1:2011 - 2 -
Foreword
The text of document 35/1270/CDV, future edition 11 of IEC 60086-1, prepared by IEC TC 35, Primary
cells and batteries, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as
EN 60086-1 on 2011-03-24.
This European Standard supersedes EN 60086-1:2007.
The major technical changes with respect to EN 60086-1:2007 are:
– the clarification of the humidity controls for testing various battery types;
– the modification of the standardization guidelines to allow for standardization of electrochemical
systems;
– the standardization of the lithium sulfuryl chloride (LiSO Cl ) and lithium sulphur dioxide (LiSO )
2 2 2
electrochemical systems.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent
rights.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2011-12-24
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2014-03-24
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of the International Standard IEC 60086-1:2011 was approved by CENELEC as a European
Standard without any modification.
__________

---------------------- Page: 4 ----------------------

SIST EN 60086-1:2011
- 3 - EN 60086-1:2011

Annex ZA
(normative)

Normative references to international publications
with their corresponding European publications

The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.

NOTE  When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.

Publication Year Title EN/HD Year

IEC 60086-2 2011 Primary batteries - EN 60086-2 2011
Part 2: Physical and electrical specifications


1)
IEC 60086-3 2011 Primary batteries - EN 60086-3 201X
Part 3: Watch batteries


IEC 60086-4 2007 Primary batteries - EN 60086-4 2007
Part 4: Safety of lithium batteries


1)
IEC 60086-5 2011 Primary batteries - EN 60086-5 201X
Part 5: Safety of batteries with aqueous
electrolyte


IEC 60410 - Sampling plans and procedures - -
for inspection by attributes


ISO/IEC Directives-1 - Procedures for the technical work - -


ISO 3951 Series Sampling procedures for inspection - -
by variables




1)
At draft stage.

---------------------- Page: 5 ----------------------

SIST EN 60086-1:2011

---------------------- Page: 6 ----------------------

SIST EN 60086-1:2011
IEC 60086-1
®

Edition 11.0 2011-02
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE


Primary batteries –
Part 1: General

Piles électriques –
Partie 1: Généralités

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
CODE PRIX X
ICS 29.220.10 ISBN 978-2-88912-359-9

® Registered trademark of the International Electrotechnical Commission
Marque déposée de la Commission Electrotechnique Internationale

---------------------- Page: 7 ----------------------

SIST EN 60086-1:2011
– 2 – 60086-1  IEC:2011
CONTENTS
FOREWORD . 5
INTRODUCTION . 7
1 Scope . 8
2 Normative references . 8
3 Terms and definitions . 8
4 Requirements . 11
4.1 General . 11
4.1.1 Design . 11
4.1.2 Battery dimensions . 11
4.1.3 Terminals . 11
4.1.4 Classification (electrochemical system) . 14
4.1.5 Designation . 14
4.1.6 Marking . 15
4.1.7 Interchangeability: battery voltage . 16
4.2 Performance . 16
4.2.1 Discharge performance. 16
4.2.2 Dimensional stability . 17
4.2.3 Leakage . 17
4.2.4 Open-circuit voltage limits . 17
4.2.5 Service output . 17
4.2.6 Safety . 17
5 Performance – Testing . 17
5.1 General . 17
5.2 Discharge testing . 17
5.2.1 General . 17
5.2.2 Application tests . 17
5.2.3 Service output tests . 18
5.3 Conformance check to a specified minimum average duration . 18
5.4 Calculation method of the specified value of minimum average duration . 19
5.5 OCV testing . 19
5.6 Battery dimensions . 19
5.7 Leakage and deformation . 19
6 Performance – Test conditions . 19
6.1 Pre-discharge conditioning . 19
6.2 Commencement of discharge tests after storage . 20
6.3 Discharge test conditions . 20
6.4 Load resistance . 20
6.5 Time periods . 20
6.6 Test condition tolerances . 21
6.7 Activation of ‘P’-system batteries . 21
6.8 Measuring equipment . 21
6.8.1 Voltage measurement . 21
6.8.2 Mechanical measurement . 21
7 Sampling and quality assurance . 21
7.1 Sampling . 21
7.1.1 Testing by attributes . 21

---------------------- Page: 8 ----------------------

SIST EN 60086-1:2011
60086-1  IEC:2011 – 3 –
7.1.2 Testing by variables . 22
7.2 Product quality indices . 22
7.2.1 General . 22
7.2.2 Capability index (c ) . 22
p
7.2.3 Capability index (c ) . 22
pk
7.2.4 Performance index (p ) . 22
p
7.2.5 Performance index (p ) . 22
pk
8 Battery packaging . 23
Annex A (normative) Guidelines for the standardization of batteries . 24
Annex B (normative) Equipment design . 25
Annex C (normative) Designation system (nomenclature) . 27
Annex D (normative) Calculation method for the specified value of minimum average
duration . 40
Annex E (normative) Code of practice for packaging, shipment, storage, use and
disposal of primary batteries . 41
Annex F (informative) Standard discharge voltage U – Definition and method of
s
determination . 44
Annex G (informative) Preparation of standard methods of measuring performance
(SMMP) of consumer goods . 48
Bibliography . 49

Figure 1 – Small cell or battery gauge (inner dimensions) . 11
Figure 2 – Stud . 13
Figure C.1 – Designation system for round batteries: d < 100 mm; height h < 100 mm . 31
1 1
Figure C.2 – Diameter code for non-recommended diameters . 32
Figure C.3 – Height code for denoting the hundredths of a millimetre of height . 33
Figure C.4 – Designation system for round batteries: d ≥ 100 mm; height h ≥ 100 mm . 34
1 1
Figure C.5 – Designation system for non round batteries, dimensions < 100 mm . 35
Figure C.6 – Designation system for non-round batteries, dimensions ≥ 100 mm . 36
Figure F.1 – Normalized C/R-plot (schematic) . 45
Figure F.2 – Standard discharge voltage (schematic) . 46

Table 1 – Spacing of contacts . 13
Table 2 – Snap fastener connectors . 13
Table 3 – Standardized electrochemical systems . 14
Table 4 – Marking requirements . 15
Table 5 – Conditions for storage before and during discharge testing . 19
Table 6 – Resistive loads for new tests . 20
Table 7 – Time periods for new tests . 20
Table 8 – Test condition tolerances . 21
Table A.1 – Items necessary to standardize . 24
Table C.1 – Physical designation and dimensions of round cells and batteries . 28
Table C.2 – Physical designation and nominal overall dimensions of flat cells . 29
Table C.3 – Physical designation and dimensions of square cells and batteries . 29
Table C.4 – Diameter code for recommended diameters . 32

---------------------- Page: 9 ----------------------

SIST EN 60086-1:2011
– 4 – 60086-1  IEC:2011
Table C.5 – Physical designation and dimensions of round cells and batteries based on
Clause C.2 . 38
Table C.6 – Physical designation and dimensions of non-round batteries based on
Clause C.2 . 39
Table F.1 – Standard discharge voltage by system . 47

---------------------- Page: 10 ----------------------

SIST EN 60086-1:2011
60086-1  IEC:2011 – 5 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________

PRIMARY BATTERIES –

Part 1: General


FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 60086-1 has been prepared by IEC technical committee 35:
Primary cells and batteries.
This eleventh edition cancels and replaces the tenth edition (2006) and constitutes a technical
revision.
The major technical changes with respect to the previous edition are:
– the clarification of the humidity controls for testing various battery types;
– the modification of the standardization guidelines to allow for standardization of
electrochemical systems;
– the standardization of the lithium sulfuryl chloride (LiSO Cl ) and lithium sulphur dioxide
2 2
(LiSO ) electrochemical systems.
2

---------------------- Page: 11 ----------------------

SIST EN 60086-1:2011
– 6 – 60086-1  IEC:2011
The text of this standard is based on the following documents:
CDV Report on voting
35/1270/CDV 35/1274/RVC

Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
A list of all parts in the IEC 60086 series, under the general title Primary batteries, can be
found on the IEC website.
The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed;
• withdrawn;
• replaced by a revised edition, or
• amended.

---------------------- Page: 12 ----------------------

SIST EN 60086-1:2011
60086-1  IEC:2011 – 7 –
INTRODUCTION
The technical content of this part of IEC 60086 provides fundamental requirements and
information on primary cells and batteries. All batteries within the IEC 60086 series are
considered dry cell batteries. In this sense, IEC 60086-1 is the main component of the
IEC 60086 series and forms the basis for the subsequent parts. For example, this part
includes elementary information on definitions, nomenclature, dimensions and marking. While
specific requirements are included, the content of this part tends to explain methodology (how)
and justification (why).
Over the years, this part has been changed to improve its content and remains under
continual scrutiny to ensure that the publication is kept up to date with the advances in both
battery and battery-powered device technologies.
NOTE Safety information is available in IEC 60086-4, IEC 60086-5 and IEC 62281.

---------------------- Page: 13 ----------------------

SIST EN 60086-1:2011
– 8 – 60086-1  IEC:2011
PRIMARY BATTERIES –

Part 1: General



1 Scope
This part of IEC 60086 is intended to standardize primary batteries with respect to dimensions,
nomenclature, terminal configurations, markings, test methods, typical performance, safety
and environmental aspects.
As a primary battery classification tool, electrochemical systems are also standardized with
respect to system letter, electrodes, electrolyte, nominal and maximum open circuit voltage.
NOTE The requirements justifying the inclusion or the ongoing retention of batteries in the IEC 60086 series are
given in Annex A.
The object of IEC 60086-1 is to benefit primary battery users, device designers and battery
manufacturers by ensuring that batteries from different manufacturers are interchangeable
according to standard form, fit and function. Furthermore, to ensure compliance with the
above, this part specifies standard test methods for testing primary cells and batteries.
2 Normative references
The following referenced documents are indispensable for the application of this document.
For dated references, only the edition cited applies. For undated references, the latest edition
of the referenced document (including any amendments) applies.
IEC 60086-2:2011, Primary batteries – Part 2: Physical and electrical specifications
IEC 60086-3:2011, Primary batteries – Part 3: Watch batteries
IEC 60086-4:2007, Primary batteries – Part 4: Safety of lithium batteries
IEC 60086-5:2011, Primary batteries – Part 5: Safety of batteries with aqueous electrolyte
IEC 60410, Sampling plans and procedures for inspection by attributes
ISO/IEC Directives, Part 1: Procedures for the technical work
ISO 3951(all parts, as applicable), Sampling procedures
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1
application test
simulation of the actual use of a battery in a specific application

---------------------- Page: 14 ----------------------

SIST EN 60086-1:2011
60086-1  IEC:2011 – 9 –
3.2
battery
one or more cells electrically connected by permanent means, fitted in a case, with terminals,
markings and protective devices etc., as necessary for use
[IEC 60050-482:2004, 482-01-04, modified]
3.3
button battery
small round battery, where the overall height is less than the diameter; batteries complying
with Figures 3 and 4 of IEC 60086-2
3.4
cell
basic functional unit, consisting of an assembly of electrodes, electrolyte, container, terminals
and usually separators, that is a source of electric energy obtained by direct conversion of
chemical energy
[IEC 60050-482:2004, 482-01-01]
3.5
closed-circuit voltage
CCV (abbreviation)
voltage across the terminals of a battery when it is on discharge
[IEC 60050-482:2004, 482-03-28, modified]
3.6
cylindrical (cell or battery)
cell or battery with a cylindrical shape in which the overall height is equal to or greater than
the diameter
[IEC 60050-482: 2004, 482-02-39, modified]
3.7
discharge (of a primary battery)
operation during which a battery delivers current to an external circuit
[IEC 60050-482:2004, 482-03-23, modified]
3.8
dry (primary) battery
primary battery in which the liquid electrolyte is essentially immobilized
[IEC 60050-482:2004, 482-04-14, modified]
3.9
effective internal resistance – DC method
The internal d.c. resistance of any electrochemical cell is defined by the following relation:
∆U (V)
R (Ω) =
i
∆i (A)
3.10
end-point voltage
EV (abbreviation)
specified voltage of a battery at which the battery discharge is terminated

---------------------- Page: 15 ----------------------

SIST EN 60086-1:2011
– 10 – 60086-1  IEC:2011
[IEC 60050-482:2004, 482-03-30, modified]
3.11
leakage
unplanned escape of electrolyte, gas or other material from a cell or battery
[IEC 60050-482:2004, 482-02-32]
3.12
minimum average duration
MAD (abbreviation)
minimum average time on discharge which is met by a sample of batteries
NOTE The discharge test is carried out according to the specified methods or standards and designed to show
conformity with the standard applicable to the battery types.
3.13
nominal voltage (of a primary battery)
V (symbol)
n
suitable approximate value of the voltage used to designate or identify a cell, a battery or an
electrochemical system
[IEC 60050-482:2004, 482-03-31, modified]
3.14
open-circuit voltage
OCV (abbreviation)
voltage across the terminals of a battery when it is off discharge
[IEC 60050-482:2004, 482-03-32, modified]
3.15
primary (cell or battery)
cell or battery that is not designed to be electrically recharged
3.16
round (cell or battery)
cell or battery with circular cross section
3.17
service output (of a primary battery)
service life, or capacity, or energy output of a battery under specified conditions of discharge
3.18
service output test
test designed to measure the service output of a battery
NOTE A service output test may be prescribed, for example, when
a) an application test is too complex to replicate;
b) the duration of an application test would make it impractical for routine testing purposes .
3.19
small battery
cell or battery fitting within the limits of the truncated cylinder as defined in Figure 1

---------------------- Page: 16 ----------------------

SIST EN 60086-1:2011
60086-1  IEC:2011 – 11 –
   Dimensions in millimetres

+0,1
∅ 31,7
 0
IEC  265/11

Figure 1 – Small cell or battery gauge (inner dimensions)
3.20
storage life
duration under specified conditions at the end of which a battery retains its ability to perform a
specified service output
[IEC 60050-482:2004, 482-03-47, modified]
3.21
terminals (of a primary battery)
conductive parts provided for the connection of a battery to external conductors
4 Requirements
4.1 General
4.1.1 Design
Primary batteries are sold mainly in consumer markets. In recent years, they have become
more sophisticated in both chemistry and construction, for example both capacity and rate
capability have increased to meet the growing demands from new, battery-powered
equipment technology.
When designing primary batteries, the aforementioned considerations shall be taken into
account. Specifically, their dimensional conformity and stability, their physical and electrical
performance and their safe operation under normal use and
...