SIST ES 201 468 V1.6.1:2016
(Main)Additional ElectroMagnetic Compatibility (EMC) requirements and resistibility requirements for telecommunications equipment for enhanced availability of service in specific applications
Additional ElectroMagnetic Compatibility (EMC) requirements and resistibility requirements for telecommunications equipment for enhanced availability of service in specific applications
The present document covers the emission, immunity and resistibility requirements for telecommunications equipment
where higher performance is required by operators to guarantee enhanced availability of service in specific applications.
The environments considered in the present document are defined in ETSI TR 101 651 [i.5] and are:
- telecommunication centres (classes 1 and 2 of ETSI TR 101 651 [i.5]);
- locations other than telecommunication centres (classes 3 and 4 of ETSI TR 101 651 [i.5]).
Data centres and similar facilities are also considered telecommunication centres, where they are within a dedicated
room with servers, storage devices and associated telecommunication equipment.
Considering that all kinds of equipment are not equally important, two equipment categories and associated EMC
requirements are introduced and are designated as:
- level 1 (see tables in clauses 9.1.1.1 to 9.1.1.5 and 9.2.1.1 to 9.2.1.5);
- level 2 (see tables in clauses 9.1.2.1 to 9.1.2.5 and 9.2.2.1 to 9.2.2.5);
the latter containing the more demanding requirements.
The appropriate level should be chosen by the operator considering the consequences of failure of the equipment which
may lead to impaired function, loss of service, failure to meet contractual obligations or bad publicity and loss of
reputation.
The present document is applicable to all equipment types, examples of which are listed below:
- switching equipment which includes trunk and local telephone exchanges, remote switching concentrators,
international switches, telex switches and network packet switches;
- transmission equipment which includes multiplexers, line equipment and repeaters, Synchronous Digital
Hierarchy (SDH), Digital Cross Connect (DXC), Asynchronous Transfer Mode (ATM) and network
terminations;
- power supply equipment which includes central power plant, end of suite power supplies, power management
systems and other dedicated telecommunications network power supplies;
- supervisory equipment and dedicated Operation And Maintenance (OAM) equipment;
- tariff and billing equipment;
- data centre equipment which includes: Storage, Processor, Server intended to be used within
telecommunication network infrastructure.
Dodatne zahteve za elektromagnetno združljivost (EMC) in odpornost telekomunikacijske opreme za povečano razpoložljivost storitve v posebnih oblikah uporabe
Ta dokument obravnava zahteve glede sevanja in odpornosti za telekomunikacijsko opremo, kadar se zahteva večja učinkovitost, da lahko operaterji zagotovijo povečano razpoložljivost storitve v posebnih oblikah uporabe.
Okolja, zajeta v tem dokumentu, so opredeljena v standardu ETSI TR 101 651 [i.5] in vključujejo:
– telekomunikacijske centre (razreda 1 in 2 standarda ETSI TR 101 651 [i.5]);
– lokacije, ki niso telekomunikacijski centri (razreda 3 in 4 standarda ETSI TR 101 651 [i.5]).
Podatkovni centri in podobni objekti se prav tako obravnavajo kot telekomunikacijski centri, kadar so v namenskem prostoru s strežniki, napravami za shranjevanje in povezano telekomunikacijsko opremo.
Ker vse vrste opreme niso enako pomembne, sta uvedeni kategoriji opreme s povezanimi zahtevami za elektromagnetno združljivost označeni kot:
– raven 1 (glej tabele v točkah 9.1.1.1 do 9.1.1.5 in 9.2.1.1 do 9.2.1.5);
– raven 2 (glej tabele v točkah 9.1.2.1 do 9.1.2.5 in 9.2.2.1 do 9.2.2.5);
pri čemer slednja vsebuje strožje zahteve.
Ustrezno raven naj izbere operater ob upoštevanju posledic odpovedi opreme, ki lahko povzročijo nepravilno delovanje, izgubo storitve, neizpolnjevanje pogodbenih obveznosti ali slabo reklamo in izgubo ugleda.
Ta dokument se uporablja za vse vrste opreme, navedene v nadaljevanju:
– stikalna oprema, ki vključuje medkrajevne in krajevne telefonske centrale, daljinske stikalne koncentratorje, mednarodna stikala, teleks stikala in omrežna paketna stikala;
– oprema za prenos, ki vključuje multiplekserje, linijsko opremo in ponavljalnike, sinhrono digitalno hierarhijo (SDH), digitalno prevezovanje (DXC), asinhroni prenosni način (ATM) in omrežne zaključke;
– napajalna oprema, ki vključuje centralno elektrarno, napajanje končne garniture, sisteme za upravljanje porabe in druge namenske telekomunikacijske omrežne napajalnike;
– nadzorna oprema ter namenska oprema za delovanje in vzdrževanje (OAM);
– oprema za tarife in obračunavanje;
– oprema za podatkovne centre, ki vključuje: prostor za shranjevanje, procesor in strežnik za uporabo znotraj
strukture telekomunikacijskega omrežja.
General Information
Buy Standard
Standards Content (Sample)
ETSI ES 201 468 V1.6.1 (2016-07)
ETSI STANDARD
Additional ElectroMagnetic Compatibility (EMC)
requirements and resistibility requirements for
telecommunications equipment for enhanced availability
of service in specific applications
---------------------- Page: 1 ----------------------
2 ETSI ES 201 468 V1.6.1 (2016-07)
Reference
RES/ERM-EMC-348
Keywords
EMC, management, network, power supply,
switching, testing, transmission
ETSI
650 Route des Lucioles
F-06921 Sophia Antipolis Cedex - FRANCE
Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16
Siret N° 348 623 562 00017 - NAF 742 C
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° 7803/88
Important notice
The present document can be downloaded from:
http://www.etsi.org/standards-search
The present document may be made available in electronic versions and/or in print. The content of any electronic and/or
print versions of the present document shall not be modified without the prior written authorization of ETSI. In case of any
existing or perceived difference in contents between such versions and/or in print, the only prevailing document is the
print of the Portable Document Format (PDF) version kept on a specific network drive within ETSI Secretariat.
Users of the present document should be aware that the document may be subject to revision or change of status.
Information on the current status of this and other ETSI documents is available at
https://portal.etsi.org/TB/ETSIDeliverableStatus.aspx
If you find errors in the present document, please send your comment to one of the following services:
https://portal.etsi.org/People/CommiteeSupportStaff.aspx
Copyright Notification
No part may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying
and microfilm except as authorized by written permission of ETSI.
The content of the PDF version shall not be modified without the written authorization of ETSI.
The copyright and the foregoing restriction extend to reproduction in all media.
© European Telecommunications Standards Institute 2016.
All rights reserved.
TM TM TM
DECT , PLUGTESTS , UMTS and the ETSI logo are Trade Marks of ETSI registered for the benefit of its Members.
TM
3GPP and LTE™ are Trade Marks of ETSI registered for the benefit of its Members and
of the 3GPP Organizational Partners.
GSM® and the GSM logo are Trade Marks registered and owned by the GSM Association.
ETSI
---------------------- Page: 2 ----------------------
3 ETSI ES 201 468 V1.6.1 (2016-07)
Contents
Intellectual Property Rights . 5
Foreword . 5
Modal verbs terminology . 5
Introduction . 5
1 Scope . 6
2 References . 6
2.1 Normative references . 6
2.2 Informative references . 7
3 Definitions and abbreviations . 8
3.1 Definitions . 8
3.2 Abbreviations . 10
4 General operational conditions . 11
4.0 General requirements . 11
4.1 Equipment configuration . 11
4.2 Exercising equipment . 11
4.3 Laboratory environment . 11
5 General performance criteria for immunity tests . 12
5.0 General requirements . 12
5.1 Performance criterion A . 12
5.2 Performance criterion B . 12
5.3 Performance criterion C . 12
6 Immunity: test methods . 13
6.1 General . 13
6.2 Electrostatic discharge . 13
6.3 Electrical fast transients/burst . 13
6.4 Surges . 13
6.4.1 Outdoor signal line ports . 13
6.4.2 Indoor signal line ports . 13
6.4.3 AC power line ports . 13
6.5 Immunity to continuous conducted signals . 13
6.5.1 AC power supply port . 13
6.5.2 DC power supply interface port . 14
6.5.3 Signal line port . 14
6.6 Immunity to radiated electromagnetic fields . 14
6.7 Immunity to power supply disturbances: AC and DC ports . 14
6.7.1 Test of immunity to low frequency disturbances: AC ports . 14
6.7.2 Test of immunity to low frequency disturbances: DC ports . 14
6.8 Immunity to interference from permanent power induction . 14
6.9 Power frequency magnetic fields . 14
7 Resistibility: test methods . 15
7.1 Electrostatic discharge . 15
7.2 Lightning . 15
7.3 Power induction and earth potential rise . 15
7.4 Mains power contact . 15
8 Emission: test methods and limits . 15
9 Immunity requirements . 15
9.0 General requirements . 15
9.1 Equipment operating in telecommunication centres . 17
9.1.1 Telecommunication centres, level 1. 17
9.1.1.1 Telecommunication centres, enclosure port, level 1 . 17
9.1.1.2 Telecommunication centres, ports for outdoor signal lines, level 1 . 17
ETSI
---------------------- Page: 3 ----------------------
4 ETSI ES 201 468 V1.6.1 (2016-07)
9.1.1.3 Telecommunication centres, ports for indoor signal lines, level 1 . 17
9.1.1.4 Telecommunication centres, AC power ports, level 1 . 18
9.1.1.5 Telecommunication centres, DC power ports, level 1 . 18
9.1.2 Telecommunication centres, level 2. 18
9.1.2.1 Telecommunication centres, enclosure port, level 2 . 18
9.1.2.2 Telecommunication centres, ports for outdoor signal lines, level 2 . 19
9.1.2.3 Telecommunication centres, ports for indoor signal lines, level 2 . 19
9.1.2.4 Telecommunication centres, AC power ports, level 2 . 20
9.1.2.5 Telecommunication centres, DC power ports, level 2 . 21
9.2 Equipment operating in locations other than telecommunication centres . 21
9.2.1 Equipment operating in locations other than telecommunication centres, level 1 . 21
9.2.1.1 Other than telecommunication centres, enclosure port, level 1 . 21
9.2.1.2 Other than telecommunication centres, ports for outdoor signal lines, level 1 . 22
9.2.1.3 Other than telecommunication centres, ports for indoor signal lines, level 1 . 22
9.2.1.4 Other than telecommunication centres, AC power ports, level 1 . 22
9.2.1.5 Other than telecommunication centres, DC power ports, level 1 . 22
9.2.2 Equipment operating in locations other than telecommunication centres, level 2 . 23
9.2.2.1 Other than telecommunication centres, enclosure port, level 2 . 23
9.2.2.2 Other than telecommunication centres, ports for outdoor signal lines, level 2 . 24
9.2.2.3 Other than telecommunication centres, ports for indoor signal lines, level 2 . 25
9.2.2.4 Other than telecommunication centres, AC power ports, level 2 . 26
9.2.2.5 Other than telecommunication centres, DC power ports, level 2 . 26
10 Resistibility requirements . 27
Annex A (normative): Surges: test method for ports of signal lines remaining within the
building . 28
A.0 General . 28
A.1 Test set-up for ports with ISDN interface . 28
Annex B (informative): Evaluation of test results . 30
Annex C (informative): Guidance for the product specific operational conditions and
performance criteria . 32
C.1 General . 32
C.2 Operational conditions and performance criteria during EMC tests . 32
C.2.1 General considerations . 32
C.2.2 Operational conditions during EMC tests . 33
C.2.3 Performance criteria during EMC tests . 33
C.2.4 Examples of specific performance criteria . 34
C.2.5 Example of additional performance criteria (and further details of requirements) for "primary rate
multiple access" equipment . 34
Annex D (informative): Bibliography . 35
History . 36
ETSI
---------------------- Page: 4 ----------------------
5 ETSI ES 201 468 V1.6.1 (2016-07)
Intellectual Property Rights
IPRs essential or potentially essential to the present document may have been declared to ETSI. The information
pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found
in ETSI SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in
respect of ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web
server (https://ipr.etsi.org/).
Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee
can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web
server) which are, or may be, or may become, essential to the present document.
Foreword
This ETSI Standard (ES) has been produced by ETSI Technical Committee Electromagnetic compatibility and Radio
spectrum Matters (ERM).
The present document defines the EMC requirements of telecommunication network equipment for an increased
reliability and the resistibility requirements.
Modal verbs terminology
In the present document "shall", "shall not", "should", "should not", "may", "need not", "will", "will not", "can" and
"cannot" are to be interpreted as described in clause 3.2 of the ETSI Drafting Rules (Verbal forms for the expression of
provisions).
"must" and "must not" are NOT allowed in ETSI deliverables except when used in direct citation.
Introduction
The present document defines EMC requirements for telecommunications equipment to guarantee enhanced availability
of service in specific applications. Resistibility requirements are also defined with reference to ITU-T K series
recommendations.
ETSI
---------------------- Page: 5 ----------------------
6 ETSI ES 201 468 V1.6.1 (2016-07)
1 Scope
The present document covers the emission, immunity and resistibility requirements for telecommunications equipment
where higher performance is required by operators to guarantee enhanced availability of service in specific applications.
The environments considered in the present document are defined in ETSI TR 101 651 [i.5] and are:
- telecommunication centres (classes 1 and 2 of ETSI TR 101 651 [i.5]);
- locations other than telecommunication centres (classes 3 and 4 of ETSI TR 101 651 [i.5]).
Data centres and similar facilities are also considered telecommunication centres, where they are within a dedicated
room with servers, storage devices and associated telecommunication equipment.
Considering that all kinds of equipment are not equally important, two equipment categories and associated EMC
requirements are introduced and are designated as:
- level 1 (see tables in clauses 9.1.1.1 to 9.1.1.5 and 9.2.1.1 to 9.2.1.5);
- level 2 (see tables in clauses 9.1.2.1 to 9.1.2.5 and 9.2.2.1 to 9.2.2.5);
the latter containing the more demanding requirements.
The appropriate level should be chosen by the operator considering the consequences of failure of the equipment which
may lead to impaired function, loss of service, failure to meet contractual obligations or bad publicity and loss of
reputation.
The present document is applicable to all equipment types, examples of which are listed below:
- switching equipment which includes trunk and local telephone exchanges, remote switching concentrators,
international switches, telex switches and network packet switches;
- transmission equipment which includes multiplexers, line equipment and repeaters, Synchronous Digital
Hierarchy (SDH), Digital Cross Connect (DXC), Asynchronous Transfer Mode (ATM) and network
terminations;
- power supply equipment which includes central power plant, end of suite power supplies, power management
systems and other dedicated telecommunications network power supplies;
- supervisory equipment and dedicated Operation And Maintenance (OAM) equipment;
- tariff and billing equipment;
- data centre equipment which includes: Storage, Processor, Server intended to be used within
telecommunication network infrastructure.
2 References
2.1 Normative references
References are either specific (identified by date of publication and/or edition number or version number) or
non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the
referenced document (including any amendments) applies.
Referenced documents which are not found to be publicly available in the expected location might be found at
http://docbox.etsi.org/Reference.
NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee
their long term validity.
ETSI
---------------------- Page: 6 ----------------------
7 ETSI ES 201 468 V1.6.1 (2016-07)
The following referenced documents are necessary for the application of the present document.
[1] ETSI EN 300 386 (V2.1.1): "Telecommunication network equipment; ElectroMagnetic
Compatibility (EMC) requirements; Harmonised Standard covering the essential requirements of
the Directive 2014/30/EU".
[2] CENELEC EN 61000-4-2:2009: "Electromagnetic compatibility (EMC); Part 4-2: Testing and
measurement techniques - Electrostatic discharge immunity test".
[3] CENELEC EN 61000-4-3 (2006 + Amendment 1: 2008 + Amendment 2: 2010 + Interpretation
Sheet: 2009): "Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement
techniques - Radiated, radio-frequency, electromagnetic field immunity test".
[4] CENELEC EN 61000-4-4:2012: "Electromagnetic compatibility (EMC); Part 4-4: Testing and
measurement techniques - Electrical fast transient/burst immunity test".
[5] CENELEC EN 61000-4-5:2006: "Electromagnetic compatibility (EMC); Part 4-5: Testing and
measurement techniques - Surge immunity test".
NOTE The dated reference of CENELEC EN 61000-4-5 has not been updated to the latest version because of the
significant technical changes in comparison with the referenced revision. For some test laboratories,
updating equipment will be a significant additional cost hence more time is required for implementation.
[6] CENELEC EN 61000-4-6:2009: "Electromagnetic compatibility (EMC); Part 4-6: Testing and
measurement techniques - Immunity to conducted disturbances, induced by radio-frequency
fields".
NOTE The dated reference of CENELEC EN 61000-4-6 has not been updated to the latest version because of the
significant technical changes in comparison with the referenced revision. For some test laboratories,
updating equipment will be a significant additional cost hence more time is required for implementation.
[7] CENELEC EN 61000-4-8:2010: "Electromagnetic compatibility (EMC); Part 4-8: Testing and
measurement techniques - Power frequency magnetic field immunity test".
[8] CENELEC EN 61000-4-11:2004: "Electromagnetic compatibility (EMC); Part 4-11: Testing and
measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests".
[9] Recommendation ITU-T K.54 (12-2004): "Conducted immunity test method and level at
fundamental power frequencies".
[10] Recommendation ITU-T K.20 (04-2015): "Resistibility of telecommunication equipment installed
in a telecommunications centre to overvoltages and overcurrents".
[11] Recommendation ITU-T K.21 (04-2015): "Resistibility of telecommunication equipment installed
in customer premises to overvoltages and overcurrents".
[12] Recommendation ITU-T K.45 (04-2015): "Resistibility of telecommunication equipment installed
in the access and trunk networks to overvoltages and overcurrents".
2.2 Informative references
References are either specific (identified by date of publication and/or edition number or version number) or
non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the
referenced document (including any amendments) applies.
NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee
their long term validity.
The following referenced documents are not necessary for the application of the present document but they assist the
user with regard to a particular subject area.
[i.1] Recommendation ITU-T K.44 (05-2012): "Resistibility tests for telecommunication equipment
exposed to overvoltages and overcurrents - Basic Recommendation".
ETSI
---------------------- Page: 7 ----------------------
8 ETSI ES 201 468 V1.6.1 (2016-07)
[i.2] ETSI ETS 300 132-1 (09-1996): "Equipment Engineering (EE); Power supply interface at the
input to telecommunications equipment; Part 1: Operated by alternating current (ac) derived from
direct current (dc) sources".
[i.3] ETSI EN 300 132-2 (V2.4.6): "Environmental Engineering (EE); Power supply interface at the
input to telecommunications and datacom (ICT) equipment; Part 2: Operated by -48 V direct
current (dc)".
[i.4] IEC 60050-161 (1990): "International Electrotechnical Vocabulary; Chapter 161: Electromagnetic
compatibility".
[i.5] ETSI TR 101 651 (V2.1.1): "Classification of the electromagnetic environment conditions for
equipment in telecommunication networks".
[i.6] ETSI EN 300 132-3-1 (V2.1.1): "Environmental Engineering (EE); Power supply interface at the
input to telecommunications and datacom (ICT) equipment; Part 3: Operated by rectified current
source, alternating current source or direct current source up to 400 V; Sub-part 1: Direct current
source up to 400 V".
[i.7] IEEE 1284™ (2000): "IEEE Standard Signalling Method for a Bidirectional Parallel Peripheral
Interface for Personal Computers".
[i.8] IEEE 1394™ (2008): "IEEE Standard for High Performance Serial Bus Bridges".
[i.9] CENELEC EN 55022 (2010): "Information technology equipment - Radio disturbance
characteristics - Limits and methods of measurement".
[i.10] CENELEC EN 55032 (2012): "Electromagnetic compatibility of multimedia equipment -
Emission requirements".
3 Definitions and abbreviations
3.1 Definitions
For the purposes of the present document, the terms and definitions given in IEC 60050-161 [i.4] and the following
apply:
NOTE: Where applicable, the clause number of IEC 60050-161 [i.4] is in parenthesis.
Audio (low) Frequency (AF): frequency interval from 0 Hz to 20 kHz
NOTE: It may sometimes be convenient to extend the use of this term to include the range of frequencies up to
150 kHz.
burst (161-02-07): sequence of a limited number of distinct pulses or an oscillation of limited duration
characteristic severity: characteristic severity for a certain detail parameter in an environmental class states a severity
which has only a low probability (generally less than 1 %) of being exceeded
NOTE: The term relates to duration, rate of occurrence or location. It applies to requirements on the environment
and to immunity requirements.
continuous disturbance (161-02-11): electromagnetic disturbance the effects of which on a particular device or
equipment cannot be resolved into a succession of distinct effects
data centre: structure, or group of structures, dedicated to the centralized accommodation, interconnection and
operation of information technology and network telecommunications equipment providing data storage, processing and
transport services together with all the facilities and infrastructures for power distribution and environmental control
together with the necessary levels of resilience and security required to provide the desired service availability
discontinuous interference (161-02-13): electromagnetic interference occurring during certain time intervals separated
by interference-free intervals
ETSI
---------------------- Page: 8 ----------------------
9 ETSI ES 201 468 V1.6.1 (2016-07)
duration (of a pulse): interval of time between the instants at which the instantaneous value of a pulse reaches 50 % of
the pulse magnitude for the first and last time
duration (of a voltage change) (161-08-03): interval of time for the voltage to increase or decrease from the initial
value to the final value
environment, environmental conditions: electromagnetic conditions external to the equipment, to which it is
subjected at a certain time
NOTE: The environmental conditions comprise a combination of single environmental parameters and their
severities.
environmental class: representation of the environment on locations with similar properties
NOTE: They are specified and standardized to provide an operational frame of reference for:
- requirements on the environment;
- immunity requirements.
The class is described using an envelope of environmental conditions expressed in terms of a number of
environmental parameters and their characteristic severities or other characteristics. The environmental
parameters specified for the class are limited to those which may affect equipment performance.
environmental parameters: present one or more properties of the electromagnetic environment
immunity (to a disturbance) (161-01-20): ability of a device, equipment or system to perform without degradation in
the presence of an electromagnetic disturbance
impulsive disturbance (161-02-09): electromagnetic disturbance which, when incident on a particular device or
equipment, manifests itself as a succession of distinct pulses or transients
level: measures on a relative scale how important it is that the equipment operates as specified
NOTE: Two levels are defined for the purpose of the present document and are de
...
Final draft ETSI ES 201 468 V1.6.1 (2016-05)
ETSI STANDARD
Additional ElectroMagnetic Compatibility (EMC)
requirements and resistibility requirements for
telecommunications equipment for enhanced availability of
service in specific applications
---------------------- Page: 1 ----------------------
2 Final draft ETSI ES 201 468 V1.6.1 (2016-05)
Reference
RES/ERM-EMC-348
Keywords
EMC, management, network, power supply,
switching, testing, transmission
ETSI
650 Route des Lucioles
F-06921 Sophia Antipolis Cedex - FRANCE
Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16
Siret N° 348 623 562 00017 - NAF 742 C
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° 7803/88
Important notice
The present document can be downloaded from:
http://www.etsi.org/standards-search
The present document may be made available in electronic versions and/or in print. The content of any electronic and/or
print versions of the present document shall not be modified without the prior written authorization of ETSI. In case of any
existing or perceived difference in contents between such versions and/or in print, the only prevailing document is the
print of the Portable Document Format (PDF) version kept on a specific network drive within ETSI Secretariat.
Users of the present document should be aware that the document may be subject to revision or change of status.
Information on the current status of this and other ETSI documents is available at
https://portal.etsi.org/TB/ETSIDeliverableStatus.aspx
If you find errors in the present document, please send your comment to one of the following services:
https://portal.etsi.org/People/CommiteeSupportStaff.aspx
Copyright Notification
No part may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying
and microfilm except as authorized by written permission of ETSI.
The content of the PDF version shall not be modified without the written authorization of ETSI.
The copyright and the foregoing restriction extend to reproduction in all media.
© European Telecommunications Standards Institute 2016.
All rights reserved.
TM TM TM
DECT , PLUGTESTS , UMTS and the ETSI logo are Trade Marks of ETSI registered for the benefit of its Members.
TM
3GPP and LTE™ are Trade Marks of ETSI registered for the benefit of its Members and
of the 3GPP Organizational Partners.
GSM® and the GSM logo are Trade Marks registered and owned by the GSM Association.
ETSI
---------------------- Page: 2 ----------------------
3 Final draft ETSI ES 201 468 V1.6.1 (2016-05)
Contents
Intellectual Property Rights . 5
Foreword . 5
Modal verbs terminology . 5
Introduction . 5
1 Scope . 6
2 References . 7
2.1 Normative references . 7
2.2 Informative references . 8
3 Definitions and abbreviations . 8
3.1 Definitions . 8
3.2 Abbreviations . 11
4 General operational conditions . 11
4.0 General requirements . 11
4.1 Equipment configuration . 11
4.2 Exercising equipment . 12
4.3 Laboratory environment . 12
5 General performance criteria for immunity tests . 12
5.0 General requirements . 12
5.1 Performance criterion A . 12
5.2 Performance criterion B . 12
5.3 Performance criterion C . 13
6 Immunity: test methods . 13
6.1 General . 13
6.2 Electrostatic discharge . 13
6.3 Electrical fast transients/burst . 13
6.4 Surges . 13
6.4.1 Outdoor signal line ports . 13
6.4.2 Indoor signal line ports . 13
6.4.3 AC power line ports . 13
6.5 Immunity to continuous conducted signals . 13
6.5.1 AC power supply port . 13
6.5.2 DC power supply interface port . 14
6.5.3 Signal line port . 14
6.6 Immunity to radiated electromagnetic fields . 14
6.7 Immunity to power supply disturbances: AC and DC ports . 14
6.7.1 Test of immunity to low frequency disturbances: AC ports . 14
6.7.2 Test of immunity to low frequency disturbances: DC ports . 14
6.8 Immunity to interference from permanent power induction . 14
6.9 Power frequency magnetic fields . 14
7 Resistibility: test methods . 15
7.1 Electrostatic discharge . 15
7.2 Lightning . 15
7.3 Power induction and earth potential rise . 15
7.4 Mains power contact . 15
8 Emission: test methods and limits . 15
9 Immunity requirements . 15
9.0 General requirements . 15
9.1 Equipment operating in telecommunication centres . 16
9.1.1 Telecommunication centres, level 1. 16
9.1.1.1 Telecommunication centres, enclosure port, level 1 . 16
9.1.1.2 Telecommunication centres, ports for outdoor signal lines, level 1 . 16
ETSI
---------------------- Page: 3 ----------------------
4 Final draft ETSI ES 201 468 V1.6.1 (2016-05)
9.1.1.3 Telecommunication centres, ports for indoor signal lines, level 1 . 16
9.1.1.4 Telecommunication centres, AC power ports, level 1 . 16
9.1.1.5 Telecommunication centres, DC power ports, level 1 . 17
9.1.2 Telecommunication centres, level 2. 17
9.1.2.1 Telecommunication centres, enclosure port, level 2 . 17
9.1.2.2 Telecommunication centres, ports for outdoor signal lines, level 2 . 18
9.1.2.3 Telecommunication centres, ports for indoor signal lines, level 2 . 18
9.1.2.4 Telecommunication centres, AC power ports, level 2 . 19
9.1.2.5 Telecommunication centres, DC power ports, level 2 . 20
9.2 Equipment operating in locations other than telecommunication centres . 20
9.2.1 Equipment operating in locations other than telecommunication centres, level 1 . 20
9.2.1.1 Other than telecommunication centres, enclosure port, level 1 . 20
9.2.1.2 Other than telecommunication centres, ports for outdoor signal lines, level 1 . 21
9.2.1.3 Other than telecommunication centres, ports for indoor signal lines, level 1 . 21
9.2.1.4 Other than telecommunication centres, AC power ports, level 1 . 21
9.2.1.5 Other than telecommunication centres, DC power ports, level 1 . 21
9.2.2 Equipment operating in locations other than telecommunication centres, level 2 . 22
9.2.2.1 Other than telecommunication centres, enclosure port, level 2 . 22
9.2.2.2 Other than telecommunication centres, ports for outdoor signal lines, level 2 . 23
9.2.2.3 Other than telecommunication centres, ports for indoor signal lines, level 2 . 24
9.2.2.4 Other than telecommunication centres, AC power ports, level 2 . 25
9.2.2.5 Other than telecommunication centres, DC power ports, level 2 . 25
10 Resistibility requirements . 26
Annex A (normative): Surges: test method for ports of signal lines remaining within the
building . 27
A.0 General . 27
A.1 Test set-up for ports with ISDN interface . 27
Annex B (informative): Evaluation of test results . 29
Annex C (informative): Guidance for the product specific operational conditions and
performance criteria . 31
C.1 General . 31
C.2 Operational conditions and performance criteria during EMC tests . 31
C.2.1 General considerations . 31
C.2.2 Operational conditions during EMC tests . 32
C.2.3 Performance criteria during EMC tests . 32
C.2.4 Examples of specific performance criteria . 33
C.2.5 Example of additional performance criteria (and further details of requirements) for "primary rate
multiple access" equipment . 33
Annex D (informative): Bibliography . 34
History . 35
ETSI
---------------------- Page: 4 ----------------------
5 Final draft ETSI ES 201 468 V1.6.1 (2016-05)
Intellectual Property Rights
IPRs essential or potentially essential to the present document may have been declared to ETSI. The information
pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found
in ETSI SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in
respect of ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web
server (https://ipr.etsi.org/).
Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee
can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web
server) which are, or may be, or may become, essential to the present document.
Foreword
This final draft ETSI Standard (ES) has been produced by ETSI Technical Committee Electromagnetic compatibility
and Radio spectrum Matters (ERM), and is now submitted for the ETSI standards Membership Approval Procedure.
The present document defines the EMC requirements of telecommunication network equipment for an increased
reliability and the resistibility requirements.
Modal verbs terminology
In the present document "shall", "shall not", "should", "should not", "may", "need not", "will", "will not", "can" and
"cannot" are to be interpreted as described in clause 3.2 of the ETSI Drafting Rules (Verbal forms for the expression of
provisions).
"must" and "must not" are NOT allowed in ETSI deliverables except when used in direct citation.
Introduction
The present document defines EMC requirements for telecommunications equipment to guarantee enhanced availability
of service in specific applications. Resistibility requirements are also defined with reference to ITU-T K series
recommendations.
ETSI
---------------------- Page: 5 ----------------------
6 Final draft ETSI ES 201 468 V1.6.1 (2016-05)
1 Scope
The present document covers the emission, immunity and resistibility requirements for telecommunications equipment
where higher performance is required by operators to guarantee enhanced availability of service in specific applications.
The environments considered in the present document are defined in ETSI TR 101 651 [i.5] and are:
- telecommunication centres (classes 1 and 2 of ETSI TR 101 651 [i.5]);
- locations other than telecommunication centres (classes 3 and 4 of ETSI TR 101 651 [i.5]).
Data centres and similar facilities are also considered telecommunication centres, where they are within a dedicated
room with servers, storage devices and associated telecommunication equipment.
Considering that all kinds of equipment are not equally important, two equipment categories and associated EMC
requirements are introduced and are designated as:
- level 1 (see tables in clauses 9.1.1.1 to 9.1.1.5 and 9.2.1.1 to 9.2.1.5);
- level 2 (see tables in clauses 9.1.2.1 to 9.1.2.5 and 9.2.2.1 to 9.2.2.5);
the latter containing the more demanding requirements.
The appropriate level should be chosen by the operator considering the consequences of failure of the equipment which
may lead to impaired function, loss of service, failure to meet contractual obligations or bad publicity and loss of
reputation.
The present document is applicable to all equipment types, examples of which are listed below:
- switching equipment which includes trunk and local telephone exchanges, remote switching concentrators,
international switches, telex switches and network packet switches;
- transmission equipment which includes multiplexers, line equipment and repeaters, Synchronous Digital
Hierarchy (SDH), Digital Cross Connect (DXC), Asynchronous Transfer Mode (ATM) and network
terminations;
- power supply equipment which includes central power plant, end of suite power supplies, power management
systems and other dedicated telecommunications network power supplies;
- supervisory equipment and dedicated Operation And Maintenance (OAM) equipment;
- tariff and billing equipment;
- Data centre equipment which includes: Storage, Processor, Server intended to be used within
telecommunication network infrastructure.
ETSI
---------------------- Page: 6 ----------------------
7 Final draft ETSI ES 201 468 V1.6.1 (2016-05)
2 References
2.1 Normative references
References are either specific (identified by date of publication and/or edition number or version number) or
non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the
referenced document (including any amendments) applies.
Referenced documents which are not found to be publicly available in the expected location might be found at
http://docbox.etsi.org/Reference.
NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee
their long term validity.
The following referenced documents are necessary for the application of the present document.
[1] ETSI EN 300 386 (V2.1.1): "Telecommunication network equipment; ElectroMagnetic
Compatibility (EMC) requirements; Harmonised Standard covering the essential requirements of
the Directive 2014/30/EU".
[2] CENELEC EN 61000-4-2:2009: "Electromagnetic compatibility (EMC); Part 4-2: Testing and
measurement techniques - Electrostatic discharge immunity test".
[3] CENELEC EN 61000-4-3 (2006 + Amendment 1: 2008 + Amendment 2: 2010 + Interpretation
Sheet: 2009): "Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement
techniques - Radiated, radio-frequency, electromagnetic field immunity test".
[4] CENELEC EN 61000-4-4:2012: "Electromagnetic compatibility (EMC); Part 4-4: Testing and
measurement techniques - Electrical fast transient/burst immunity test".
[5] CENELEC EN 61000-4-5:2006: "Electromagnetic compatibility (EMC); Part 4-5: Testing and
measurement techniques - Surge immunity test".
NOTE The dated reference of CENELEC EN 61000-4-5 has not been updated to the latest version because of the
significant technical changes in comparison with the referenced revision. For some test laboratories,
updating equipment will be a significant additional cost hence more time is required for implementation.
[6] CENELEC EN 61000-4-6:2009: "Electromagnetic compatibility (EMC); Part 4-6: Testing and
measurement techniques - Immunity to conducted disturbances, induced by radio-frequency
fields".
NOTE The dated reference of CENELEC EN 61000-4-6 has not been updated to the latest version because of the
significant technical changes in comparison with the referenced revision. For some test laboratories,
updating equipment will be a significant additional cost hence more time is required for implementation.
[7] CENELEC EN 61000-4-8:2010: "Electromagnetic compatibility (EMC); Part 4-8: Testing and
measurement techniques - Power frequency magnetic field immunity test".
[8] CENELEC EN 61000-4-11:2004: "Electromagnetic compatibility (EMC); Part 4-11: Testing and
measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests".
[9] Recommendation ITU-T K.54 (12-2004): "Conducted immunity test method and level at
fundamental power frequencies".
[10] Recommendation ITU-T K.20 (04-2015): "Resistibility of telecommunication equipment installed
in a telecommunications centre to overvoltages and overcurrents".
[11] Recommendation ITU-T K.21 (04-2015): "Resistibility of telecommunication equipment installed
in customer premises to overvoltages and overcurrents".
[12] Recommendation ITU-T K.45 (04-2015): "Resistibility of telecommunication equipment installed
in the access and trunk networks to overvoltages and overcurrents".
ETSI
---------------------- Page: 7 ----------------------
8 Final draft ETSI ES 201 468 V1.6.1 (2016-05)
2.2 Informative references
References are either specific (identified by date of publication and/or edition number or version number) or
non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the
referenced document (including any amendments) applies.
NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee
their long term validity.
The following referenced documents are not necessary for the application of the present document but they assist the
user with regard to a particular subject area.
[i.1] Recommendation ITU-T K.44 (05-2012): "Resistibility tests for telecommunication equipment
exposed to overvoltages and overcurrents - Basic Recommendation".
[i.2] ETSI ETS 300 132-1 (09-1996): "Equipment Engineering (EE); Power supply interface at the
input to telecommunications equipment; Part 1: Operated by alternating current (ac) derived from
direct current (dc) sources".
[i.3] ETSI EN 300 132-2 (V2.4.6): "Environmental Engineering (EE); Power supply interface at the
input to telecommunications and datacom (ICT) equipment; Part 2: Operated by -48 V direct
current (dc)".
[i.4] IEC 60050-161 (1990): "International Electrotechnical Vocabulary; Chapter 161: Electromagnetic
compatibility".
[i.5] ETSI TR 101 651 (V2.1.1): "Classification of the electromagnetic environment conditions for
equipment in telecommunication networks".
[i.6] ETSI EN 300 132-3-1 (V2.1.1): "Environmental Engineering (EE); Power supply interface at the
input to telecommunications and datacom (ICT) equipment; Part 3: Operated by rectified current
source, alternating current source or direct current source up to 400 V; Sub-part 1: Direct current
source up to 400 V".
[i.7] IEEE 1284™ (2000): "IEEE Standard Signalling Method for a Bidirectional Parallel Peripheral
Interface for Personal Computers".
[i.8] IEEE 1394™ (2008): "IEEE Standard for High Performance Serial Bus Bridges".
[i.9] CENELEC EN 55022 (2010): "Information technology equipment - Radio disturbance
characteristics - Limits and methods of measurement".
[i.10] CENELEC EN 55032 (2012): "Electromagnetic compatibility of multimedia equipment -
Emission requirements".
3 Definitions and abbreviations
3.1 Definitions
For the purposes of the present document, the terms and definitions given in IEC 60050-161 [i.4] and the following
apply:
NOTE: Where applicable, the clause number of IEC 60050-161 [i.4] is in parenthesis.
Audio (low) Frequency (AF): frequency interval from 0 Hz to 20 kHz
NOTE: It may sometimes be convenient to extend the use of this term to include the range of frequencies up to
150 kHz.
burst (161-02-07): sequence of a limited number of distinct pulses or an oscillation of limited duration
ETSI
---------------------- Page: 8 ----------------------
9 Final draft ETSI ES 201 468 V1.6.1 (2016-05)
characteristic severity: characteristic severity for a certain detail parameter in an environmental class states a severity
which has only a low probability (generally less than 1 %) of being exceeded
NOTE: The term relates to duration, rate of occurrence or location. It applies to requirements on the environment
and to immunity requirements.
continuous disturbance (161-02-11): electromagnetic disturbance the effects of which on a particular device or
equipment cannot be resolved into a succession of distinct effects
data centre: structure, or group of structures, dedicated to the centralized accommodation, interconnection and
operation of information technology and network telecommunications equipment providing data storage, processing and
transport services together with all the facilities and infrastructures for power distribution and environmental control
together with the necessary levels of resilience and security required to provide the desired service availability
discontinuous interference (161-02-13): electromagnetic interference occurring during certain time intervals separated
by interference-free intervals
duration (of a voltage change) (161-08-03): interval of time for the voltage to increase or decrease from the initial
value to the final value
duration (of a pulse): interval of time between the instants at which the instantaneous value of a pulse reaches 50 % of
the pulse magnitude for the first and last time
environment, environmental conditions: electromagnetic conditions external to the equipment, to which it is
subjected at a certain time
NOTE: The environmental conditions comprise a combination of single environmental parameters and their
severities.
environmental class: representation of the environment on locations with similar properties
NOTE: They are specified and standardized to provide an operational frame of reference for:
- requirements on the environment;
- immunity requirements.
The class is described using an envelope of environmental conditions expressed in terms of a number of
environmental parameters and their characteristic severities or other characteristics. The environmental
parameters specified for the class are limited to those which may affect equipment performance.
environmental parameters: present one or more properties of the electromagnetic environment
immunity (to a disturbance) (161-01-20): ability of a device, equipment or system to perform without degradation in
the presence of an electromagnetic disturbance
impulsive disturbance (161-02-09): electromagnetic disturbance which, when incident on a particular device or
equipment, manifests itself as a succession of distinct pulses or tr
...
SLOVENSKI STANDARD
SIST ES 201 468 V1.6.1:2016
01-oktober-2016
'RGDWQH]DKWHYH]DHOHNWURPDJQHWQR]GUXåOMLYRVW(0&LQRGSRUQRVW
WHOHNRPXQLNDFLMVNHRSUHPH]DSRYHþDQRUD]SRORåOMLYRVWVWRULWYHYSRVHEQLK
REOLNDKXSRUDEH
Additional ElectroMagnetic Compatibility (EMC) requirements and resistibility
requirements for telecommunications equipment for enhanced availability of service in
specific applications
Ta slovenski standard je istoveten z: ETSI ES 201 468 V1.6.1 (2016-07)
ICS:
33.060.99 Druga oprema za radijske Other equipment for
komunikacije radiocommunications
33.100.01 Elektromagnetna združljivost Electromagnetic compatibility
na splošno in general
SIST ES 201 468 V1.6.1:2016 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST ES 201 468 V1.6.1:2016
---------------------- Page: 2 ----------------------
SIST ES 201 468 V1.6.1:2016
ETSI ES 201 468 V1.6.1 (2016-07)
ETSI STANDARD
Additional ElectroMagnetic Compatibility (EMC)
requirements and resistibility requirements for
telecommunications equipment for enhanced availability
of service in specific applications
---------------------- Page: 3 ----------------------
SIST ES 201 468 V1.6.1:2016
2 ETSI ES 201 468 V1.6.1 (2016-07)
Reference
RES/ERM-EMC-348
Keywords
EMC, management, network, power supply,
switching, testing, transmission
ETSI
650 Route des Lucioles
F-06921 Sophia Antipolis Cedex - FRANCE
Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16
Siret N° 348 623 562 00017 - NAF 742 C
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° 7803/88
Important notice
The present document can be downloaded from:
http://www.etsi.org/standards-search
The present document may be made available in electronic versions and/or in print. The content of any electronic and/or
print versions of the present document shall not be modified without the prior written authorization of ETSI. In case of any
existing or perceived difference in contents between such versions and/or in print, the only prevailing document is the
print of the Portable Document Format (PDF) version kept on a specific network drive within ETSI Secretariat.
Users of the present document should be aware that the document may be subject to revision or change of status.
Information on the current status of this and other ETSI documents is available at
https://portal.etsi.org/TB/ETSIDeliverableStatus.aspx
If you find errors in the present document, please send your comment to one of the following services:
https://portal.etsi.org/People/CommiteeSupportStaff.aspx
Copyright Notification
No part may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying
and microfilm except as authorized by written permission of ETSI.
The content of the PDF version shall not be modified without the written authorization of ETSI.
The copyright and the foregoing restriction extend to reproduction in all media.
© European Telecommunications Standards Institute 2016.
All rights reserved.
TM TM TM
DECT , PLUGTESTS , UMTS and the ETSI logo are Trade Marks of ETSI registered for the benefit of its Members.
TM
3GPP and LTE™ are Trade Marks of ETSI registered for the benefit of its Members and
of the 3GPP Organizational Partners.
GSM® and the GSM logo are Trade Marks registered and owned by the GSM Association.
ETSI
---------------------- Page: 4 ----------------------
SIST ES 201 468 V1.6.1:2016
3 ETSI ES 201 468 V1.6.1 (2016-07)
Contents
Intellectual Property Rights . 5
Foreword . 5
Modal verbs terminology . 5
Introduction . 5
1 Scope . 6
2 References . 6
2.1 Normative references . 6
2.2 Informative references . 7
3 Definitions and abbreviations . 8
3.1 Definitions . 8
3.2 Abbreviations . 10
4 General operational conditions . 11
4.0 General requirements . 11
4.1 Equipment configuration . 11
4.2 Exercising equipment . 11
4.3 Laboratory environment . 11
5 General performance criteria for immunity tests . 12
5.0 General requirements . 12
5.1 Performance criterion A . 12
5.2 Performance criterion B . 12
5.3 Performance criterion C . 12
6 Immunity: test methods . 13
6.1 General . 13
6.2 Electrostatic discharge . 13
6.3 Electrical fast transients/burst . 13
6.4 Surges . 13
6.4.1 Outdoor signal line ports . 13
6.4.2 Indoor signal line ports . 13
6.4.3 AC power line ports . 13
6.5 Immunity to continuous conducted signals . 13
6.5.1 AC power supply port . 13
6.5.2 DC power supply interface port . 14
6.5.3 Signal line port . 14
6.6 Immunity to radiated electromagnetic fields . 14
6.7 Immunity to power supply disturbances: AC and DC ports . 14
6.7.1 Test of immunity to low frequency disturbances: AC ports . 14
6.7.2 Test of immunity to low frequency disturbances: DC ports . 14
6.8 Immunity to interference from permanent power induction . 14
6.9 Power frequency magnetic fields . 14
7 Resistibility: test methods . 15
7.1 Electrostatic discharge . 15
7.2 Lightning . 15
7.3 Power induction and earth potential rise . 15
7.4 Mains power contact . 15
8 Emission: test methods and limits . 15
9 Immunity requirements . 15
9.0 General requirements . 15
9.1 Equipment operating in telecommunication centres . 17
9.1.1 Telecommunication centres, level 1. 17
9.1.1.1 Telecommunication centres, enclosure port, level 1 . 17
9.1.1.2 Telecommunication centres, ports for outdoor signal lines, level 1 . 17
ETSI
---------------------- Page: 5 ----------------------
SIST ES 201 468 V1.6.1:2016
4 ETSI ES 201 468 V1.6.1 (2016-07)
9.1.1.3 Telecommunication centres, ports for indoor signal lines, level 1 . 17
9.1.1.4 Telecommunication centres, AC power ports, level 1 . 18
9.1.1.5 Telecommunication centres, DC power ports, level 1 . 18
9.1.2 Telecommunication centres, level 2. 18
9.1.2.1 Telecommunication centres, enclosure port, level 2 . 18
9.1.2.2 Telecommunication centres, ports for outdoor signal lines, level 2 . 19
9.1.2.3 Telecommunication centres, ports for indoor signal lines, level 2 . 19
9.1.2.4 Telecommunication centres, AC power ports, level 2 . 20
9.1.2.5 Telecommunication centres, DC power ports, level 2 . 21
9.2 Equipment operating in locations other than telecommunication centres . 21
9.2.1 Equipment operating in locations other than telecommunication centres, level 1 . 21
9.2.1.1 Other than telecommunication centres, enclosure port, level 1 . 21
9.2.1.2 Other than telecommunication centres, ports for outdoor signal lines, level 1 . 22
9.2.1.3 Other than telecommunication centres, ports for indoor signal lines, level 1 . 22
9.2.1.4 Other than telecommunication centres, AC power ports, level 1 . 22
9.2.1.5 Other than telecommunication centres, DC power ports, level 1 . 22
9.2.2 Equipment operating in locations other than telecommunication centres, level 2 . 23
9.2.2.1 Other than telecommunication centres, enclosure port, level 2 . 23
9.2.2.2 Other than telecommunication centres, ports for outdoor signal lines, level 2 . 24
9.2.2.3 Other than telecommunication centres, ports for indoor signal lines, level 2 . 25
9.2.2.4 Other than telecommunication centres, AC power ports, level 2 . 26
9.2.2.5 Other than telecommunication centres, DC power ports, level 2 . 26
10 Resistibility requirements . 27
Annex A (normative): Surges: test method for ports of signal lines remaining within the
building . 28
A.0 General . 28
A.1 Test set-up for ports with ISDN interface . 28
Annex B (informative): Evaluation of test results . 30
Annex C (informative): Guidance for the product specific operational conditions and
performance criteria . 32
C.1 General . 32
C.2 Operational conditions and performance criteria during EMC tests . 32
C.2.1 General considerations . 32
C.2.2 Operational conditions during EMC tests . 33
C.2.3 Performance criteria during EMC tests . 33
C.2.4 Examples of specific performance criteria . 34
C.2.5 Example of additional performance criteria (and further details of requirements) for "primary rate
multiple access" equipment . 34
Annex D (informative): Bibliography . 35
History . 36
ETSI
---------------------- Page: 6 ----------------------
SIST ES 201 468 V1.6.1:2016
5 ETSI ES 201 468 V1.6.1 (2016-07)
Intellectual Property Rights
IPRs essential or potentially essential to the present document may have been declared to ETSI. The information
pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found
in ETSI SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in
respect of ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web
server (https://ipr.etsi.org/).
Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee
can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web
server) which are, or may be, or may become, essential to the present document.
Foreword
This ETSI Standard (ES) has been produced by ETSI Technical Committee Electromagnetic compatibility and Radio
spectrum Matters (ERM).
The present document defines the EMC requirements of telecommunication network equipment for an increased
reliability and the resistibility requirements.
Modal verbs terminology
In the present document "shall", "shall not", "should", "should not", "may", "need not", "will", "will not", "can" and
"cannot" are to be interpreted as described in clause 3.2 of the ETSI Drafting Rules (Verbal forms for the expression of
provisions).
"must" and "must not" are NOT allowed in ETSI deliverables except when used in direct citation.
Introduction
The present document defines EMC requirements for telecommunications equipment to guarantee enhanced availability
of service in specific applications. Resistibility requirements are also defined with reference to ITU-T K series
recommendations.
ETSI
---------------------- Page: 7 ----------------------
SIST ES 201 468 V1.6.1:2016
6 ETSI ES 201 468 V1.6.1 (2016-07)
1 Scope
The present document covers the emission, immunity and resistibility requirements for telecommunications equipment
where higher performance is required by operators to guarantee enhanced availability of service in specific applications.
The environments considered in the present document are defined in ETSI TR 101 651 [i.5] and are:
- telecommunication centres (classes 1 and 2 of ETSI TR 101 651 [i.5]);
- locations other than telecommunication centres (classes 3 and 4 of ETSI TR 101 651 [i.5]).
Data centres and similar facilities are also considered telecommunication centres, where they are within a dedicated
room with servers, storage devices and associated telecommunication equipment.
Considering that all kinds of equipment are not equally important, two equipment categories and associated EMC
requirements are introduced and are designated as:
- level 1 (see tables in clauses 9.1.1.1 to 9.1.1.5 and 9.2.1.1 to 9.2.1.5);
- level 2 (see tables in clauses 9.1.2.1 to 9.1.2.5 and 9.2.2.1 to 9.2.2.5);
the latter containing the more demanding requirements.
The appropriate level should be chosen by the operator considering the consequences of failure of the equipment which
may lead to impaired function, loss of service, failure to meet contractual obligations or bad publicity and loss of
reputation.
The present document is applicable to all equipment types, examples of which are listed below:
- switching equipment which includes trunk and local telephone exchanges, remote switching concentrators,
international switches, telex switches and network packet switches;
- transmission equipment which includes multiplexers, line equipment and repeaters, Synchronous Digital
Hierarchy (SDH), Digital Cross Connect (DXC), Asynchronous Transfer Mode (ATM) and network
terminations;
- power supply equipment which includes central power plant, end of suite power supplies, power management
systems and other dedicated telecommunications network power supplies;
- supervisory equipment and dedicated Operation And Maintenance (OAM) equipment;
- tariff and billing equipment;
- data centre equipment which includes: Storage, Processor, Server intended to be used within
telecommunication network infrastructure.
2 References
2.1 Normative references
References are either specific (identified by date of publication and/or edition number or version number) or
non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the
referenced document (including any amendments) applies.
Referenced documents which are not found to be publicly available in the expected location might be found at
http://docbox.etsi.org/Reference.
NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee
their long term validity.
ETSI
---------------------- Page: 8 ----------------------
SIST ES 201 468 V1.6.1:2016
7 ETSI ES 201 468 V1.6.1 (2016-07)
The following referenced documents are necessary for the application of the present document.
[1] ETSI EN 300 386 (V2.1.1): "Telecommunication network equipment; ElectroMagnetic
Compatibility (EMC) requirements; Harmonised Standard covering the essential requirements of
the Directive 2014/30/EU".
[2] CENELEC EN 61000-4-2:2009: "Electromagnetic compatibility (EMC); Part 4-2: Testing and
measurement techniques - Electrostatic discharge immunity test".
[3] CENELEC EN 61000-4-3 (2006 + Amendment 1: 2008 + Amendment 2: 2010 + Interpretation
Sheet: 2009): "Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement
techniques - Radiated, radio-frequency, electromagnetic field immunity test".
[4] CENELEC EN 61000-4-4:2012: "Electromagnetic compatibility (EMC); Part 4-4: Testing and
measurement techniques - Electrical fast transient/burst immunity test".
[5] CENELEC EN 61000-4-5:2006: "Electromagnetic compatibility (EMC); Part 4-5: Testing and
measurement techniques - Surge immunity test".
NOTE The dated reference of CENELEC EN 61000-4-5 has not been updated to the latest version because of the
significant technical changes in comparison with the referenced revision. For some test laboratories,
updating equipment will be a significant additional cost hence more time is required for implementation.
[6] CENELEC EN 61000-4-6:2009: "Electromagnetic compatibility (EMC); Part 4-6: Testing and
measurement techniques - Immunity to conducted disturbances, induced by radio-frequency
fields".
NOTE The dated reference of CENELEC EN 61000-4-6 has not been updated to the latest version because of the
significant technical changes in comparison with the referenced revision. For some test laboratories,
updating equipment will be a significant additional cost hence more time is required for implementation.
[7] CENELEC EN 61000-4-8:2010: "Electromagnetic compatibility (EMC); Part 4-8: Testing and
measurement techniques - Power frequency magnetic field immunity test".
[8] CENELEC EN 61000-4-11:2004: "Electromagnetic compatibility (EMC); Part 4-11: Testing and
measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests".
[9] Recommendation ITU-T K.54 (12-2004): "Conducted immunity test method and level at
fundamental power frequencies".
[10] Recommendation ITU-T K.20 (04-2015): "Resistibility of telecommunication equipment installed
in a telecommunications centre to overvoltages and overcurrents".
[11] Recommendation ITU-T K.21 (04-2015): "Resistibility of telecommunication equipment installed
in customer premises to overvoltages and overcurrents".
[12] Recommendation ITU-T K.45 (04-2015): "Resistibility of telecommunication equipment installed
in the access and trunk networks to overvoltages and overcurrents".
2.2 Informative references
References are either specific (identified by date of publication and/or edition number or version number) or
non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the
referenced document (including any amendments) applies.
NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee
their long term validity.
The following referenced documents are not necessary for the application of the present document but they assist the
user with regard to a particular subject area.
[i.1] Recommendation ITU-T K.44 (05-2012): "Resistibility tests for telecommunication equipment
exposed to overvoltages and overcurrents - Basic Recommendation".
ETSI
---------------------- Page: 9 ----------------------
SIST ES 201 468 V1.6.1:2016
8 ETSI ES 201 468 V1.6.1 (2016-07)
[i.2] ETSI ETS 300 132-1 (09-1996): "Equipment Engineering (EE); Power supply interface at the
input to telecommunications equipment; Part 1: Operated by alternating current (ac) derived from
direct current (dc) sources".
[i.3] ETSI EN 300 132-2 (V2.4.6): "Environmental Engineering (EE); Power supply interface at the
input to telecommunications and datacom (ICT) equipment; Part 2: Operated by -48 V direct
current (dc)".
[i.4] IEC 60050-161 (1990): "International Electrotechnical Vocabulary; Chapter 161: Electromagnetic
compatibility".
[i.5] ETSI TR 101 651 (V2.1.1): "Classification of the electromagnetic environment conditions for
equipment in telecommunication networks".
[i.6] ETSI EN 300 132-3-1 (V2.1.1): "Environmental Engineering (EE); Power supply interface at the
input to telecommunications and datacom (ICT) equipment; Part 3: Operated by rectified current
source, alternating current source or direct current source up to 400 V; Sub-part 1: Direct current
source up to 400 V".
[i.7] IEEE 1284™ (2000): "IEEE Standard Signalling Method for a Bidirectional Parallel Peripheral
Interface for Personal Computers".
[i.8] IEEE 1394™ (2008): "IEEE Standard for High Performance Serial Bus Bridges".
[i.9] CENELEC EN 55022 (2010): "Information technology equipment - Radio disturbance
characteristics - Limits and methods of measurement".
[i.10] CENELEC EN 55032 (2012): "Electromagnetic compatibility of multimedia equipment -
Emission requirements".
3 Definitions and abbreviations
3.1 Definitions
For the purposes of the present document, the terms and definitions given in IEC 60050-161 [i.4] and the following
apply:
NOTE: Where applicable, the clause number of IEC 60050-161 [i.4] is in parenthesis.
Audio (low) Frequency (AF): frequency interval from 0 Hz to 20 kHz
NOTE: It may sometimes be convenient to extend the use of this term to include the range of frequencies up to
150 kHz.
burst (161-02-07): sequence of a limited number of distinct pulses or an oscillation of limited duration
characteristic severity: characteristic severity for a certain detail parameter in an environmental class states a severity
which has only a low probability (generally less than 1 %) of being exceeded
NOTE: The term relates to duration, rate of occurrence or location. It applies to requirements on the environment
and to immunity requirements.
continuous disturbance (161-02-11): electromagnetic disturbance the effects of which on a particular device or
equipment cannot be resolved into a succession of distinct effects
data centre: structure, or group of structures, dedicated to the centralized accommodation, interconnection and
operation of information technology and network telecommunications equipment providing data storage, processing and
transport services together with all the facilities and infrastructures for power distribution and environmental control
together with the necessary levels of resilience and security required to provide the desired service availability
discontinuous interference (161-02-13): electromagnetic interference occurring during certain time intervals separated
by interference-free intervals
ETSI
---------------------- Page: 10 ----------------------
SIST ES 201 468 V1.6.1:2016
9 ETSI ES 201 468 V1.6.1 (2016-07)
duration (of a pulse): interval of time between the instants at which the instantaneous value of a pulse reaches 50 % of
the pulse magnitude for the first and last time
duration (of a voltage change) (161-08-03): interval of time for the voltage to increase or decrease from the initial
value to the final value
environment, environmental conditions: electromagnetic conditions external to the equipment, to which it is
subjected at a certain time
NOTE: The environmental conditions comprise a combination of
...
Questions, Comments and Discussion