Radio Equipment and Systems (RES); ElectroMagnetic Compatibility (EMC) standard for Citizens Band (CB) radio and ancillary equipment (speech and/or non-speech); Part 2: Double Side Band (DSB) and/or Single Side Band (SSB)

This ETS together with ETS 300 433 covers the asessment of Citizen s Band radio equipment in respect of EMC and may be used to demonstrate presumption of compliance with the protection requirements of the EMC Directive. ETS covers amplitude modulated (AM) equipment: DSB and/or SSB.

Radijska oprema in sistemi (RES) - Standard elektromagnetne združljivosti (EMC) radijske in pomožne opreme (govorne oziroma negovorne) za radiotelefonijo za občane (CB) - 2. del: Dvobočna amplitudna (DSB) modulacija oziroma enobočna amplitudna modulacija (SSB)

General Information

Status
Published
Publication Date
30-Sep-1998
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
01-Oct-1998
Due Date
01-Oct-1998
Completion Date
01-Oct-1998
Mandate

Buy Standard

Standard
ETS 300 680-2:1998
English language
27 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST ETS 300 680-2:1998
01-oktober-1998
5DGLMVNDRSUHPDLQVLVWHPL 5(6 6WDQGDUGHOHNWURPDJQHWQH]GUXåOMLYRVWL (0&
UDGLMVNHLQSRPRåQHRSUHPH JRYRUQHR]LURPDQHJRYRUQH ]DUDGLRWHOHIRQLMR]D
REþDQH &% GHO'YRERþQDDPSOLWXGQD '6% PRGXODFLMDR]LURPDHQRERþQD
DPSOLWXGQDPRGXODFLMD 66%
Radio Equipment and Systems (RES); ElectroMagnetic Compatibility (EMC) standard for
Citizens Band (CB) radio and ancillary equipment (speech and/or non-speech); Part 2:
Double Side Band (DSB) and/or Single Side Band (SSB)
Ta slovenski standard je istoveten z: ETS 300 680-2 Edition 1
ICS:
33.060.20 Sprejemna in oddajna Receiving and transmitting
oprema equipment
33.100.01 Elektromagnetna združljivost Electromagnetic compatibility
na splošno in general
SIST ETS 300 680-2:1998 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST ETS 300 680-2:1998

---------------------- Page: 2 ----------------------

SIST ETS 300 680-2:1998
EUROPEAN ETS 300 680-2
TELECOMMUNICATION March 1997
STANDARD
Source: ETSI TC-RES Reference: DE/RES-09021-2
ICS: 33.020
Key words: CB, EMC, radio, testing
Radio Equipment and Systems (RES);
ElectroMagnetic Compatibility (EMC) standard for
Citizens' Band (CB) radio and ancillary equipment
(speech and/or non-speech);
Part 2: Double Side Band (DSB)
and/or Single Side Band (SSB)
ETSI
European Telecommunications Standards Institute
ETSI Secretariat
Postal address: F-06921 Sophia Antipolis CEDEX - FRANCE
Office address: 650 Route des Lucioles - Sophia Antipolis - Valbonne - FRANCE
X.400: c=fr, a=atlas, p=etsi, s=secretariat - Internet: secretariat@etsi.fr
Tel.: +33 4 92 94 42 00 - Fax: +33 4 93 65 47 16
Copyright Notification: No part may be reproduced except as authorized by written permission. The copyright and the
foregoing restriction extend to reproduction in all media.
© European Telecommunications Standards Institute 1997. All rights reserved.

---------------------- Page: 3 ----------------------

SIST ETS 300 680-2:1998
Page 2
ETS 300 680-2: March 1997
Whilst every care has been taken in the preparation and publication of this document, errors in content,
typographical or otherwise, may occur. If you have comments concerning its accuracy, please write to
"ETSI Editing and Committee Support Dept." at the address shown on the title page.

---------------------- Page: 4 ----------------------

SIST ETS 300 680-2:1998
Page 3
ETS 300 680-2: March 1997
Contents
Foreword .5
1 Scope .7
2 Normative references.7
3 Definitions, abbreviations and symbols.8
3.1 Definitions .8
3.2 Abbreviations .9
3.3 Symbols .9
4 General test conditions.9
4.1 Test conditions.9
4.1.1 Emission tests .10
4.1.2 Immunity tests .10
4.1.2.1 Mode of operation.10
4.1.2.2 Normal test modulation.10
4.1.2.3 Arrangements for test signals at the input of the
transmitter.11
4.1.2.4 Arrangements for test signals at the output of the
transmitter.11
4.1.2.5 Arrangements for test signals at the input of the receiver .11
4.1.2.6 Arrangements for test signals at the output of the receiver.11
4.1.2.7 Receiver and receivers of transceivers exclusion band .12
4.1.2.8 Transmitter exclusion band .12
4.1.2.9 Narrow band responses on receivers and receivers of
transceivers .12
5 Performance assessment .12
5.1 General .12
5.2 Ancillary equipment.13
5.3 Equipment EMC environment classification .13
6 Performance criteria.13
6.1 General performance criteria.14
6.2 Specific performance criteria for continuous phenomena applied to transmitters and
receivers .16
6.3 Specific performance criteria for transient phenomena applied to transmitters and
receivers including short voltage dips.16
6.4 Specific performance criteria for long voltage dips and power interruptions applied to
transmitters and receivers .16
7 Applicability overview tables.17
7.1 Emission .17
7.2 Immunity .17
8 Test methods and limits for emission tests.18
8.1 Emission: enclosure port of ancillary equipment tested separately from other
equipment .18
8.1.1 Definition .18
8.1.2 Method of measurement: .18
8.1.3 Limits.18
8.2 Emission: DC power input/output port .18
8.2.1 Definition .18
8.2.2 Method of measurement .18
8.2.3 Limits.19

---------------------- Page: 5 ----------------------

SIST ETS 300 680-2:1998
Page 4
ETS 300 680-2: March 1997
8.3 Emission: AC mains power input/output port . 19
8.3.1 Definition. 19
8.3.2 Method of measurement. 19
8.3.3 Limits . 19
9 Test methods and limits for immunity tests . 20
9.1 Test configuration. 20
9.2 Immunity: enclosure port. 20
9.2.1 Definition. 20
9.2.2 Method of measurement. 20
9.2.2.1 Radio frequency electromagnetic field. 20
9.2.2.2 ElectroStatic Discharge (ESD). 20
9.2.3 Immunity test levels . 20
9.3 Immunity: DC power input/output port. 20
9.3.1 Definition. 20
9.3.2 Method of measurement. 21
9.3.2.1 Radio frequency electromagnetic disturbance RF
common mode, 0,15 MHz - 80 MHz (current clamp
injection). 21
9.3.2.2 Fast transients common mode . 21
9.3.3 Immunity test levels . 21
9.4 Immunity: AC power input/output port. 21
9.4.1 Definition. 21
9.4.2 Method of measurement. 22
9.4.2.1 Radio frequency electromagnetic disturbance RF
common mode, 0,15 MHz - 80 MHz (current clamp
injection). 22
9.4.2.2 Fast transients common mode . 22
9.4.2.3 Surges common and differential mode. 22
9.4.2.4 Voltage dips and power interruptions. 22
9.4.3 Immunity test levels . 23
9.5 Immunity: signal /control input/output and antenna port. 23
9.5.1 Definition. 23
9.5.2 Method of measurement. 23
9.5.2.1 Radio frequency electromagnetic disturbance RF
common mode, 0,15 MHz - 80 MHz (current clamp
injection). 23
9.5.2.2 Fast transients common mode . 23
9.5.3 Immunity test levels . 24
9.6 Immunity: vehicle DC power input port. 24
9.6.1 Definition. 24
9.6.2 Method of measurement. 24
9.6.3 Immunity test levels: 12 V DC powered equipment. 24
9.6.4 Immunity levels: 24 V DC powered equipment. 25
Annex A (normative): ETS 300 680-2: "EMC standard for Citizens' Band (CB) radio and ancillary
equipment (speech and/or non-speech); Part 2: Double Side Band (DSB)
and/or Single Side Band (SSB)" . 26
History. 27

---------------------- Page: 6 ----------------------

SIST ETS 300 680-2:1998
Page 5
ETS 300 680-2: March 1997
Foreword
This European Telecommunication Standard (ETS) has been produced by the Radio Equipment and
Systems (RES) Technical Committee of the European Telecommunications Standards Institute (ETSI) in
response to European Commission mandate BC-T-353 [2].
This ETS together with ETS 300 433 [1] is intended to become a Harmonized Electromagnetic
Compatibility (EMC) Standard, the reference of which is intended to be published in the Official Journal of
the European Commission referencing the EMC Directive, 89/336/EEC [3].
The technical specifications, which are relevant to the EMC Directive are listed in normative annex A.
This ETS is based upon the Generic Standards EN 50081-1 [4], EN 50082-1 [5], and other standards
where appropriate, to meet the essential requirements of the Council Directive 89/336/EEC [3].
This ETS consists of 2 parts as follows:
Part 1: "Angle modulated";
Part 2: "Double Side Band (DSB) and/or Single Side Band (SSB)".
Transposition dates
Date of adoption: 21 March 1997
Date of latest announcement of this ETS (doa): 30 June 1997
Date of latest publication of new National Standard
or endorsement of this ETS (dop/e): 31 December 1997
Date of withdrawal of any conflicting National Standard (dow): 31 December 1997

---------------------- Page: 7 ----------------------

SIST ETS 300 680-2:1998
Page 6
ETS 300 680-2: March 1997
Blank page

---------------------- Page: 8 ----------------------

SIST ETS 300 680-2:1998
Page 7
ETS 300 680-2: March 1997
1 Scope
This European Telecommunication Standard (ETS) covers the assessment of Double Side Band (DSB)
and/or Single Side Band (SSB) modulated Citizens' Band (CB) radio and ancillary equipment in respect of
electromagnetic compatibility (EMC).
This ETS specifies the applicable EMC tests, the test methods, the limits and the minimum performance
criteria for DSB and/or SSB modulated CB Radio equipment (speech and/or non-speech) operating in the
frequency range 26 - 28 MHz, and the associated ancillary equipment.
The environmental classification used in this ETS refers to the environment classification used in the
Generic Standards EN 50081-1 [4], EN 50082-1 [5], except for the vehicular environment class which
refers to the ISO 7637 standard [14].
The EMC requirements have been selected to ensure an adequate level of compatibility for apparatus at
residential, commercial, light industrial and vehicular environments. The levels do not cover extreme
cases which may occur in any location but have a low probability of occurrence.
This ETS may not cover those cases where a potential source of interference which is producing
individually repeated transient phenomena or a continuous phenomena is permanently present,
e.g. a radar or broadcast site in the near vicinity. In such a case it may be necessary to use special
protection applied to either the source of interference or the interfered part or both.
Compliance of radio equipment with the requirements of this ETS does not signify compliance to any
requirements related to the use of the equipment (i.e. licensing requirements).
Compliance with this ETS does not signify compliance to any safety requirements. However, it is the
responsibility of the assessor of the equipment that any observations regarding apparatus becoming
dangerous or unsafe as a result of the application of the tests of this ETS, should be recorded in the test
report.
2 Normative references
This ETS incorporates by dated and undated reference, provisions from other publications. These
normative references are cited at the appropriate places in the text and the publications are listed
hereafter. For dated references, subsequent amendments to or revisions of any of these publications
apply to this ETS only when incorporated in it by amendment or revision. For undated references the latest
edition of the publication referred to applies.
[1] ETS 300 433: "Radio Equipment and Systems (RES); Double Side Band (DSB)
and/or Single Side Band (SSB) amplitude modulated Citizens' Band radio
equipment; Technical Characteristics and methods of measurement".
[2] BC-T-353: "European Commission Standardization Mandate M/237".
[3] 89/336/EEC: "Council Directive of 3 May 1989 on the approximation of laws of
Member States relating to Electromagnetic Compatibility".
[4] EN 50081-1: "Electromagnetic compatibility - Generic emission standard. Part 1
Residential, commercial and light industry".
[5] EN 50082-1: "Electromagnetic compatibility - Generic immunity standard. Part 1:
Residential, commercial and light industry".
[6] EN 55022: "Limits and methods of measurement of radio disturbance
characteristics of information technology equipment".
[7] CISPR 16-1: "Specification for radio disturbance and immunity measuring
apparatus and methods - Part 1: Radio disturbance and immunity measuring
apparatus".

---------------------- Page: 9 ----------------------

SIST ETS 300 680-2:1998
Page 8
ETS 300 680-2: March 1997
[8] ENV 50140: "Electromagnetic Compatibility - Basic immunity standard -
Radiated, radio-frequency electromagnetic field. Immunity test".
[9] EN 61000-4-2: "Electromagnetic Compatibility (EMC) - Part 4: Testing and
measurements techniques - Section 2: Electrostatic discharge immunity test".
[10] EN 61000-4-4: "Electromagnetic Compatibility (EMC) - Part 4: Testing and
measurements techniques - Section 4: Electrical fast transients/burst
requirements".
[11] EN 61000-4-6: "Electromagnetic Compatibility (EMC) - Part 4: Testing and
measurements techniques - Section 6: Immunity to conducted disturbances,
induced by radio-frequency fields".
[12] EN 61000-4-11: "Electromagnetic compatibility (EMC) - Part 4: Testing and
measurement techniques - Section 11: "Voltage dips, short interruptions and
voltage variations immunity tests".
[13] EN 61000-4-5: "Electromagnetic compatibility (EMC) - Part 4: Testing and
measurement techniques - Section 5: Surge immunity tests".
[14] ISO 7637: "Road vehicles-Electrical disturbance by conducting and coupling";
Part 1: "Passenger cars and light commercial vehicles with nominal 12 V supply
voltage" and Part 2: "Commercial vehicles with nominal 24 V supply voltage -
Electrical transient conduction along supply lines only".
3 Definitions, abbreviations and symbols
3.1 Definitions
For the purposes of this ETS, the following definitions apply:
ancillary equipment: Equipment (apparatus), used in connection with a receiver, transmitter or
transceiver is considered as an ancillary equipment (apparatus) if:
- the equipment is intended for use in conjunction with a receiver, transmitter or transceiver to
provide additional operational and/or control features to the radio equipment (e.g. to extend control
to another position or location); and
- the equipment cannot be used on a stand alone basis to provide user functions independently of a
receiver, transmitter or transceiver; and
- the receiver, transmitter or transceiver to which it is connected, is capable of providing some
intended operation such as transmitting and/or receiving without the ancillary equipment. (i.e. it is
not a sub unit of the main equipment essential to the main equipment basic functions).
enclosure port: The physical boundary of the apparatus onto which an electromagnetic field may radiate
or impinge.
integral antenna equipment: CB equipment without an accessible external transmission line interface.
Integral antenna CB equipment in the context of this ETS should be understood to be low power handhold
CB radio equipment which is mainly used for children’s toys and similar purposes.
port: A particular interface of the specified equipment (apparatus) with the external electromagnetic
environment.

---------------------- Page: 10 ----------------------

SIST ETS 300 680-2:1998
Page 9
ETS 300 680-2: March 1997
Enclosure port
Signal/control/
AC power port antenna port
APPARATUS
DC power port Earth port
Figure 1: Examples of ports
radio communications equipment: An apparatus which includes one or more transmitters and/or
receivers and/or parts thereof.
This type of equipment (apparatus) is used in a fixed, mobile or a portable application.
switching range: The maximum frequency range over which the equipment can be operated without
reprogramming or realignment.
3.2 Abbreviations
For the purposes of this ETS the following abbreviations apply:
BER Bit Error Ratio
CB Citizens' Band
DSB Double Side Band
EMC Electromagnetic Compatibility
ESD ElectroStatic Discharge
EUT Equipment Under Test
LISN Line Impedance Stabilization Network
RF Radio Frequency
SSB Single Side Band
3.3 Symbols
For the purposes of this ETS, the following symbols apply:
emf electromotive force
SINAD Signal + Noise + Distortion to Noise + Distortion
Tx Transmit
4 General test conditions
4.1 Test conditions
This subclause defines the requirements for the general test configuration and are as follows:
- the equipment shall be tested under conditions which are within the manufacturers declared range
of humidity, temperature and supply voltage;
- the test configuration shall be as close to normal intended use as possible;
- integral antenna CB equipment shall be tested in a manner typical of normal intended use;
- if the equipment is part of a system, or can be connected to ancillary equipment, then it shall be
acceptable to test the equipment while connected to the minimum configuration of ancillary
equipment necessary to exercise the ports;
- ports which in normal operation are connected shall be connected to an ancillary equipment or to a
representative piece of cable correctly terminated to simulate the impedance of the ancillary
equipment. Radio Frequency (RF) input/output ports shall be correctly terminated;

---------------------- Page: 11 ----------------------

SIST ETS 300 680-2:1998
Page 10
ETS 300 680-2: March 1997
- if the equipment has a large number of ports, then a sufficient number shall be selected to simulate
actual operation conditions and to ensure that all the different types of termination are tested;
- ports which are not connected to cables during normal intended operation, e.g. service connectors,
programming connectors, temporary connectors etc. shall not be connected to any cables for the
purpose of EMC testing. Where cables have to be connected to these ports, or interconnecting
cables have to be extended in length in order to exercise the Equipment Under Test (EUT),
precautions shall be taken to ensure that the evaluation of the EUT is not affected by the addition or
extension of these cables;
- the tests shall be carried out at a point within the specified normal operating environmental range at
the rated supply voltage for the equipment;
- the test conditions, test configuration and mode of operation shall be recorded in the test report.
4.1.1 Emission tests
This subclause defines the requirements for the emissions test configuration and are as follows:
- the measurement shall be made in the operation mode producing the largest emission in the
frequency band being investigated consistent with normal applications;
- an attempt shall be made to maximize the detected radiated emission for example by moving the
cables of the equipment.
The CB radio equipment shall be operated on one channel frequency, which is close to the middle of the
switching range declared by the manufacturer.
4.1.2 Immunity tests
This subclause defines the requirements for the immunity test configuration and are as follows:
- the measurement shall be made in the mode of operation as required in subclause 4.1.2.1;
- for the immunity tests of ancillary equipment without a separate pass/fail criteria, the receiver,
transmitter or transceiver coupled to the ancillary equipment shall be used to judge whether the
ancillary equipment passes or fails;
- immunity tests on CB radio equipment shall be carried out on one channel which is close to the
middle of the switching range declared by the manufacturer.
4.1.2.1 Mode of operation
For the immunity tests of transmitters, the transmitter shall be operated at its maximum RF output peak
envelope power, or at a level not less than 6 dB below that power level in the event of declared thermal
limitations. The transmitter is modulated with normal test modulation (see subclauses 4.1.2.2 and 4.1.2.3).
A communication link shall be established (see subclause 4.1.2.4) at the start of the test.
For the immunity tests of receivers, the wanted input signal, coupled to the receiver, shall be modulated
with normal test modulation (see subclauses 4.1.2.2 and 4.1.2.5). A communication link shall be
established (see subclause 4.1.2.6) at the start of the test.
4.1.2.2 Normal test modulation
For analogue speech applications:
- the receiver wanted input signal shall be set to the nominal frequency of the receiver modulated
with a sinusoidal audio frequency of 1 000 Hz. In case of DSB (AM) a modulation depth of at least
60 % shall be used for the wanted test signal. For SSB receivers the wanted signal shall be in the
receiver passband at a frequency giving a 1 kHz audio output;

---------------------- Page: 12 ----------------------

SIST ETS 300 680-2:1998
Page 11
ETS 300 680-2: March 1997
- in case of DSB (AM), the transmitter of the EUT shall be modulated with a sinusoidal audio
frequency signal of 1 000 Hz. The level of this audio signal shall be set to obtain at least 60 % AM
modulation depth of the RF output signal;
- in case of SSB, the transmitter of the EUT shall be modulated with a sinusoidal audio frequency
signal of 1 000 Hz, the level shall be set to obtain 60 % of the maximum peak envelope RF output
power. The level of this audio signal shall be increased by 3 dB and this signal shall be used as
normal test modulation signal.
For non-speech applications:
- the receiver wanted input signal shall be set to the nominal frequency of the receiver modulated
with a test signal specified by the manufacturer which represents normal operation;
- the transmitter shall be modulated with a test signal which represents normal operation as specified
by the manufacturer.
The test signal generator (modulation) shall be able to produce a continuous stream of data or a repetitive
message.
The test signal receiver (demodulator) shall be able to produce a readout of Bit Error Ratio (BER) of a
continuous data stream or a repetitive readout of message acceptance.
4.1.2.3 Arrangements for test signals at the input of the transmitter
The transmitter should be modulated with normal test modulation.
4.1.2.4 Arrangements for test signals at the output of the transmitter
For integral antenna CB equipment, the wanted signal, to establish a communication link, shall be
delivered from the equipment to an antenna located within the test environment. The measuring
equipment for the wanted signal shall be located outside of the test environment. Adequate measures
shall be taken to avoid the effect of the unwanted signal on the measuring equipment.
For equipment with an external coaxial antenna connector (non-integral antenna CB-equipment), the
wanted signal to establish a communication link shall be delivered from the antenna connector by a
coaxial cable. The measuring equipment for the wanted signal shall be located outside of the test
environment. Adequate measures shall be taken to avoid any effect of the unwanted signal on the
measuring equipment.
4.1.2.5 Arrangements for test signals at the input of the receiver
For integral antenna CB equipment, the wanted input signal, to establish a communication link, shall be
presented to the equipment from an antenna located within the test environment. It shall be approximately
40 dB above the minimum level necessary to achieve normal operation performance, as declared by the
manufacturer, measured while the power amplifiers generating the EMC disturbance are switched on but
without excitation. This level of the wanted input signal is expected to represent normal operation signal
level and is sufficient to prevent the broad band noise from the power amplifiers from influencing the
measurement. The source of the wanted input signal shall be located outside of the test environment.
For equipment with an external coaxial antenna connector (non-integral antenna CB equipment), the
wanted input signal to establish a communication link shall be presented to the antenna connector by a
coaxial cable. The source of the wanted input signal shall be located outside of the test environment and
shall be at a nominal value of 40 dBμV emf.
4.1.2.6 Arrangements for test signals at the output of the receiver
For speech equipment the audio frequency output of the equipment shall be coupled via a suitable
coupling device in order to demonstrate that the communication link is maintained. Precautions shall be
taken to ensure that any effect on the test is minimized.