Transmission and Multiplexing (TM); Generic requirements of transport functionality of equipment; Part 2-2: Synchronous Digital Hierarchy (SDH) and Plesiochronous Digital Hierarchy (PDH) physical section layer functions; Implementation Conformance Statement (ICS) proforma specification

ICS proforma for ETS 300 417-2-1.

Prenos in multipleksiranje (TM) – Generične zahteve za prenosno funkcionalnost opreme – 2-2. del: Funkcije fizičnega odseka plasti za sinhrono digitalno hierarhijo (SDH) in pleziohrono digitalno hierarhijo (PDH) – Proforma specifikacija izjave o skladnosti izvedbe (ICS)

General Information

Status
Published
Publication Date
30-Nov-2003
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
01-Dec-2003
Due Date
01-Dec-2003
Completion Date
01-Dec-2003

Buy Standard

Standard
EN 300 417-2-2 V1.1.2:2003
English language
123 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 300 417-2-2 V1.1.2:2003
01-december-2003
3UHQRVLQPXOWLSOHNVLUDQMH 70 ±*HQHULþQH]DKWHYH]DSUHQRVQRIXQNFLRQDOQRVW
RSUHPH±GHO)XQNFLMHIL]LþQHJDRGVHNDSODVWL]DVLQKURQRGLJLWDOQRKLHUDUKLMR
6'+ LQSOH]LRKURQRGLJLWDOQRKLHUDUKLMR 3'+ ±3URIRUPDVSHFLILNDFLMDL]MDYHR
VNODGQRVWLL]YHGEH ,&6
Transmission and Multiplexing (TM); Generic requirements of transport functionality of
equipment; Part 2-2: Synchronous Digital Hierarchy (SDH) and Plesiochronous Digital
Hierarchy (PDH) physical section layer functions; Implementation Conformance
Statement (ICS) proforma specification
Ta slovenski standard je istoveten z: EN 300 417-2-2 Version 1.1.2
ICS:
33.040.20 Prenosni sistem Transmission systems
SIST EN 300 417-2-2 V1.1.2:2003 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 300 417-2-2 V1.1.2:2003

---------------------- Page: 2 ----------------------

SIST EN 300 417-2-2 V1.1.2:2003
EN 300 417-2-2 V1.1.2 (1998-11)
European Standard (Telecommunications series)
Transmission and Multiplexing (TM);
Generic requirements of transport functionality of equipment;
Part 2-2: Synchronous Digital Hierarchy (SDH) and
Plesiochronous Digital Hierarchy (PDH)
physical section layer functions;
Implementation Conformance Statement (ICS)
proforma specification

---------------------- Page: 3 ----------------------

SIST EN 300 417-2-2 V1.1.2:2003
2 EN 300 417-2-2 V1.1.2 (1998-11)
Reference
REN/TM-01015-2-2 (3v0iiidc.PDF)
Keywords
ICS, PDH, SDH, STM, transmission, testing
ETSI
Postal address
F-06921 Sophia Antipolis Cedex - FRANCE
Office address
650 Route des Lucioles - Sophia Antipolis
Valbonne - FRANCE
Tel.: +33 4 92 94 42 00  Fax: +33 4 93 65 47 16
Siret N° 348 623 562 00017 - NAF 742 C
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° 7803/88
Internet
secretariat@etsi.fr
Individual copies of this ETSI deliverable
can be downloaded from
http://www.etsi.org
Copyright Notification
No part may be reproduced except as authorized by written permission.
The copyright and the foregoing restriction extend to reproduction in all media.
© European Telecommunications Standards Institute 1998.
All rights reserved.
ETSI

---------------------- Page: 4 ----------------------

SIST EN 300 417-2-2 V1.1.2:2003
3 EN 300 417-2-2 V1.1.2 (1998-11)
Contents
Intellectual Property Rights.9
Foreword .9
Introduction .10
1 Scope.11
2 References.11
3 Definitions and abbreviations .12
3.1 Definitions . 12
3.2 Abbreviations. 12
4 Conformance to this ICS proforma specification .14
Annex A (normative): ICS proforma for EN 300 417-2-1.15
A.1 Guidance for completing the ICS proforma.15
A.1.1 Purposes and structure . 15
A.1.2 Abbreviations and conventions. 15
A.1.3 Instructions for completing the ICS proforma . 17
Annex B (normative): ICS proforma for STM-1 optical section layer.18
B.1 Identification of the implementation.18
B.1.1 Date of the statement . 18
B.1.2 IUT identification . 18
B.1.3 SUT identification. 18
B.1.4 Product supplier. 19
B.1.5 Client . 19
B.1.6 ICS contact person. 20
B.2 Identification of the EN.20
B.3 Global statement of conformance of OS1 layer.20
B.4 OS1 layer description.21
B.5 OS1 layer transmission tables.22
B.5.1 OS1 source operating wavelength range, OS1_TT_So. 22
B.5.2 OS1 source spectral characteristics, OS1_TT_So. 23
B.5.3 OS1 source optical characteristics, OS1_TT_So . 24
B.5.4 OS1 receiver characteristics, OS1_TT_Sk. 25
B.5.5 OS1 regeneration characteristics, OS1/RS1_A_So, OS1/RS1_A_Sk. 26
B.6 Defect, fault and performance monitoring.27
B.6.1 Port status management . 27
B.6.2 Defect detection and clearance criteria . 27
B.6.3 Consequent action activation and clearance criteria . 28
B.6.4 Defect correlation . 29
B.6.5 Performance monitoring . 29
Annex C (normative): ICS proforma for STM-4 optical section layer.30
C.1 Identification of the implementation.30
C.1.1 Date of the statement . 30
C.1.2 IUT identification . 30
C.1.3 SUT identification. 30
C.1.4 Product supplier. 31
C.1.5 Client . 31
C.1.6 ICS contact person. 32
ETSI

---------------------- Page: 5 ----------------------

SIST EN 300 417-2-2 V1.1.2:2003
4 EN 300 417-2-2 V1.1.2 (1998-11)
C.2 Identification of the EN.32
C.3 Global statement of conformance of OS4 layer.32
C.4 OS4 layer description.33
C.5 OS4 layer transmission tables.34
C.5.1 OS4 source operating wavelength range, OS4_TT_So. 34
C.5.2 OS4 source spectral characteristics, OS4_TT_So. 35
C.5.3 OS4 source optical characteristics, OS4_TT_So . 36
C.5.4 OS4 receiver characteristics, OS4_TT_Sk. 37
C.5.5 OS4 regeneration characteristics, OS4/RS4_A_So, OS4/RS4_A_Sk. 38
C.6 OS4 layer defect, fault and performance monitoring tables .39
C.6.1 Port status management . 39
C.6.2 Defect detection and clearance criteria . 39
C.6.3 Consequent action activation and clearance criteria . 40
C.6.4 Defect correlation . 41
C.6.5 Performance monitoring . 41
Annex D (normative): ICS proforma for STM-16 optical section layer.42
D.1 Identification of the implementation.42
D.1.1 Date of the statement . 42
D.1.2 IUT identification . 42
D.1.3 SUT identification. 42
D.1.4 Product supplier. 43
D.1.5 Client . 43
D.1.6 ICS contact person. 44
D.2 Identification of the EN.44
D.3 Global statement of conformance of OS16 layer.44
D.4 OS16 layer description.45
D.5 OS16 layer transmission tables.46
D.5.1 OS16 source operating wavelength range, OS16_TT_So. 46
D.5.2 OS16 source spectral characteristics, OS16_TT_So. 46
D.5.3 OS16 source optical characteristics, OS16_TT_So . 47
D.5.4 OS16 receiver characteristics, OS16_TT_Sk. 48
D.5.5 OS16 regeneration characteristics, OS16/RS16_A_So, OS16/RS16_A_Sk. 49
D.6 OS16 layer defect, fault and performance monitoring tables .50
D.6.1 Port status management . 50
D.6.2 Defect detection and clearance criteria . 50
D.6.3 Consequent action activation and clearance criteria . 51
D.6.4 Defect correlation . 52
D.6.5 Performance monitoring . 52
Annex E (normative): ICS proforma for STM-1 electrical section layer.53
E.1 Identification of the implementation.53
E.1.1 Date of the statement . 53
E.1.2 IUT identification . 53
E.1.3 SUT identification. 53
E.1.4 Product supplier. 54
E.1.5 Client . 54
E.1.6 ICS contact person. 55
ETSI

---------------------- Page: 6 ----------------------

SIST EN 300 417-2-2 V1.1.2:2003
5 EN 300 417-2-2 V1.1.2 (1998-11)
E.2 Identification of the EN.55
E.3 Global statement of conformance of ES1 layer .55
E.4 ES1 layer description .56
E.5 ES1 layer transmission tables .56
E.5.1 ES1 layer data stream. 56
E.5.2 ES1 layer connection function, ES1_C. 56
E.5.3 ES1 layer trail termination functions, ES1_TT_So and ES1_TT_Sk . 57
E.5.4 ES1 to RS1 adaptation functions, ES1/RS1_A_So and ES1/RS1_A_Sk. 58
E.6 ES1 layer defect, fault and performance monitoring tables.59
E.6.1 Port status management . 59
E.6.2 Defect detection and clearance criteria . 60
E.6.3 Consequent action activation and clearance criteria . 60
E.6.4 Defect correlation . 61
E.6.5 Performance monitoring . 61
Annex F (normative): ICS proforma for E4 electrical section layer.62
F.1 Identification of the implementation.62
F.1.1 Date of the statement . 62
F.1.2 IUT identification . 62
F.1.3 SUT identification. 62
F.1.4 Product supplier. 63
F.1.5 Client . 63
F.1.6 ICS contact person. 64
F.2 Identification of the EN.64
F.3 Global statement of conformance of E4 layer .64
F.4 E4 layer description .65
F.5 E4 layer transmission tables.65
F.5.1 E4 layer data stream. 65
F.5.2 E4 layer connection function, E4_C . 65
F.5.3 E4 layer trail termination functions, E4_TT_So and E4_TT_Sk. 66
F.5.4 E4 to P4x adaptation functions, E4/P4x_A_So and E4/P4x_A_Sk . 67
F.5.5 E4to P4e adaptation functions, E4/P4e_A_So and E4/P4e_A_Sk. 68
F.5.6 E4 to P4s adaptation functions, E4/P4s_A_So and E4/P4s_A_Sk . 69
F.6 E4 layer defect, fault and performance monitoring tables.70
F.6.1 Port status management . 70
F.6.2 Defect detection and clearance criteria . 71
F.6.3 Consequent action activation and clearance criteria . 71
F.6.4 Defect correlation . 72
Annex G (normative): ICS proforma for E31 electrical section layer.73
G.1 Identification of the implementation.73
G.1.1 Date of the statement . 73
G.1.2 IUT identification . 73
G.1.3 SUT identification. 73
G.1.4 Product supplier. 74
G.1.5 Client . 74
G.1.6 ICS contact person. 75
ETSI

---------------------- Page: 7 ----------------------

SIST EN 300 417-2-2 V1.1.2:2003
6 EN 300 417-2-2 V1.1.2 (1998-11)
G.2 Identification of the EN.75
G.3 Global statement of conformance of E31 layer .75
G.4 E31 layer description .76
G.5 E31 layer transmission tables.76
G.5.1 E31 layer data stream. 76
G.5.2 E31 layer connection function, E31_C . 76
G.5.3 E31 layer trail termination functions, E31_TT_So and E31_TT_Sk. 77
G.5.4 E31 to P31x adaptation functions, E31/P31x_A_So and E31/P31x_A_Sk . 78
G.5.5 E31to P31e adaptation functions, E31/P31e_A_So and E31/P31e_A_Sk. 79
G.5.6 E31 to P31s adaptation functions, E31/P31s_A_So and E31/P31s_A_Sk . 80
G.6 E31 layer defect, fault and performance monitoring tables.81
G.6.1 Port status management . 81
G.6.2 Defect detection and clearance criteria . 82
G.6.3 Consequent action activation and clearance criteria . 82
G.6.4 Defect correlation . 83
Annex H (normative): ICS proforma for E22 electrical section layer.84
H.1 Identification of the implementation.84
H.1.1 Date of the statement . 84
H.1.2 IUT identification . 84
H.1.3 SUT identification. 84
H.1.4 Product supplier. 85
H.1.5 Client . 85
H.1.6 ICS contact person. 86
H.2 Identification of the EN.86
H.3 Global statement of conformance of E22 layer .86
H.4 E22 layer description .87
H.5 E22 layer transmission tables.87
H.5.1 E22 layer data stream. 87
H.5.2 E22 layer connection function, E22_C . 87
H.5.3 E22 layer trail termination functions, E22_TT_So and E22_TT_Sk. 88
H.5.4 E22 to P22x adaptation functions, E22/P22x_A_So and E22/P22x_A_Sk . 89
H.5.5 E22to P22e adaptation functions, E22/P22e_A_So and E22/P22e_A_Sk. 90
H.6 E22 layer defect, fault and performance monitoring tables.91
H.6.1 Port status management . 91
H.6.2 Defect detection and clearance criteria . 91
H.6.3 Consequent action activation and clearance criteria . 92
H.6.4 Defect correlation . 93
Annex J (normative): ICS proforma for E12 electrical section layer.94
J.1 Identification of the implementation.94
J.1.1 Date of the statement . 94
J.1.2 IUT identification . 94
J.1.3 SUT identification.
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.