Radio-frequency connectors - Part 42: Sectional specification for CQN series quick lock RF coaxial connectors

This part of IEC 61169, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for CQN series RF coaxial connectors, with characteristic impedance of 50 Ω, with threaded coupling and operating frequency limit up to 11 GHz, used in wireless, microwave, telecommunication, and other fields, connecting with RF cables or micro-strips. It also prescribes mating face dimensions for general connectors-grade 2, dimensional details of standard test connectors-grade 0, gauging information and tests selected from IEC 61169-1, applicable to all detail specifications relating to CQN series connectors. This specification indicates the recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H (see Tables 8 and 9). This specification indicates the recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H.

Hochfrequenz-Steckverbinder - Teil 42: Rahmenspezifikation für koaxiale HF-Steckverbinder der CQN Serie mit Schnellverriegelung

Connecteurs pour fréquences radioélectriques - Partie 42: Spécification intermédiaire pour connecteurs coaxiaux R.F. à verrouillage rapide, série CQN

La CEI 61169-42:2013 est une spécification intermédiaire qui fournit des informations et des règles en vue de l'établissement de spécifications particulières (SP) de connecteurs coaxiaux RF de série CQN d'une impédance de 50 Ohms, doté d'un couplage fileté et d'une limite de fréquence de fonctionnement de 11 GHz, utilisés dans les domaines des appareils sans fil, hyperfréquences, télécommunications, ainsi que dans d'autres domaines, permettant la connexion avec les câbles RF ou les microrubans. Elle prescrit également les dimensions des faces d'accouplement pour des connecteurs d'usage général classe 2, les détails dimensionnels des connecteurs d essai normalisés classe 0, les informations concernant les calibres et les essais choisis dans la CEI 61169-1, applicables à toutes les spécifications particulières ayant trait aux connecteurs de la série CQN. La présente première édition annule et remplace la première édition de la CEI/PAS 61169-42 publiée en 2009.

Radiofrekvenčni konektorji - 42. del: Področna specifikacija za serijo CQN radiofrekvenčnih (RF) koaksialnih zaklepnih konektorjev (IEC 61169-42:2013)

General Information

Status
Published
Publication Date
02-Jan-2014
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
16-Dec-2013
Due Date
20-Feb-2014
Completion Date
03-Jan-2014

Buy Standard

Standard
EN 61169-42:2014
English language
30 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 61169-42:2014
01-februar-2014
5DGLRIUHNYHQþQLNRQHNWRUMLGHO3RGURþQDVSHFLILNDFLMD]DVHULMR&41
UDGLRIUHNYHQþQLK 5) NRDNVLDOQLK]DNOHSQLKNRQHNWRUMHY ,(&
Radio-frequency connectors - Part 42: Sectional specification for CQN series quick lock
RF coaxial connectors
Hochfrequenz-Steckverbinder - Teil 42: Rahmenspezifikation für koaxiale HF-
Steckverbinder der CQN Serie mit Schnellverriegelung
Ta slovenski standard je istoveten z: EN 61169-42:2013
ICS:
33.120.30 5DGLRIUHNYHQþQLNRQHNWRUML R.F. connectors
5)
SIST EN 61169-42:2014 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 61169-42:2014

---------------------- Page: 2 ----------------------

SIST EN 61169-42:2014

EUROPEAN STANDARD
EN 61169-42

NORME EUROPÉENNE
April 2013
EUROPÄISCHE NORM

ICS 33.120.30


English version


Radio-frequency connectors -
Part 42: Sectional specification for CQN series quick lock RF coaxial
connectors
(IEC 61169-42:2013)


Connecteurs pour fréquences Hochfrequenz-Steckverbinder -
radioélectriques - Teil 42: Rahmenspezifikation für koaxiale
Partie 42: Spécification intermédiaire pour HF-Steckverbinder der CQN Serie mit
connecteurs coaxiaux R.F. à verrouillage Schnellverriegelung
rapide, série CQN (IEC 61169-42:2013)
(CEI 61169-42:2013)





This European Standard was approved by CENELEC on 2013-02-20. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the CEN-CENELEC Management Centre or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the CEN-CENELEC Management Centre has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany,
Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland,
Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Management Centre: Avenue Marnix 17, B - 1000 Brussels


© 2013 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61169-42:2013 E

---------------------- Page: 3 ----------------------

SIST EN 61169-42:2014
EN 61169-42:2013 - 2 -

Foreword
The text of document 46F/142/CDV, future edition 1 of IEC 61169-42, prepared by SC 46F, "R.F. and
microwave passive components", of IEC TC 46, "Cables, wires, waveguides, R.F. connectors, R.F. and
microwave passive components and accessories" was submitted to the IEC-CENELEC parallel vote and
approved by CENELEC as EN 61169-42:2013.
The following dates are fixed:
(dop) 2013-11-20
• latest date by which the document has
to be implemented at national level by
publication of an identical national
standard or by endorsement
• latest date by which the national (dow) 2016-02-20
standards conflicting with the

document have to be withdrawn

Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such patent
rights.
Endorsement notice
The text of the International Standard IEC 61169-42:2013 was approved by CENELEC as a European
Standard without any modification.

---------------------- Page: 4 ----------------------

SIST EN 61169-42:2014
- 3 - EN 61169-42:2013
Annex ZA
(normative)

Normative references to international publications
with their corresponding European publications

The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.

NOTE  When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.

Publication Year Title EN/HD Year

IEC 61169-1 1992 Radio-frequency connectors - EN 61169-1 1994
+ A1 1996 Part 1: Generic specification - General + A1 1996
+ A2 1997 requirements and measuring methods + A2 1997

---------------------- Page: 5 ----------------------

SIST EN 61169-42:2014

---------------------- Page: 6 ----------------------

SIST EN 61169-42:2014




IEC 61169-42

®


Edition 1.0 2013-01




INTERNATIONAL



STANDARD








colour

inside










Radio-frequency connectors –

Part 42: Sectional specification for CQN series quick lock RF coaxial connectors



























INTERNATIONAL

ELECTROTECHNICAL

COMMISSION

PRICE CODE
U


ICS 33.120.30 ISBN 978-2-83220-579-2



  Warning! Make sure that you obtained this publication from an authorized distributor.


® Registered trademark of the International Electrotechnical Commission

---------------------- Page: 7 ----------------------

SIST EN 61169-42:2014
– 2 – 61169-42  IEC:2013(E)
CONTENTS
FOREWORD . 3
INTRODUCTION . 5
1 Scope . 6
2 Normative reference . 6
3 Mating face and gauge information . 6
3.1 Dimensions – General connectors – Grade 2 . 6
3.1.1 Connector with pin-centre contact . 6
3.1.2 Connector with socket-centre contact . 9
3.2 Gauges . 9
3.2.1 Gauge pins for socket-centre contact . 9
3.2.2 Test procedure . 10
3.3 Dimensions- standard test connectors – Grade 0. 11
3.3.1 Connector with pin-centre contact . 11
3.3.2 Connector with socket-centre contact . 13
4 Quality assessment procedure . 14
4.1 General . 14
4.2 Rating and characteristics (see Clause 6 of IEC 61169-1:1992) . 14
4.3 Test schedule and inspection requirements – Acceptance tests . 17
4.3.1 Acceptance tests . 17
4.3.2 Periodic tests. 18
4.4 Procedures . 20
4.4.1 Quality conformance inspection . 20
4.4.2 Qualification approval and its maintenance . 20
5 Instructions for preparation of detail specifications . 21
5.1 General . 21
5.2 Identification of the component . 21
5.3 Performance . 21
5.4 Marking, ordering information and related matters . 21
5.5 Selection of tests, test conditions and severities . 21
5.6 Blank detail specification pro-forma for type CQN connector . 23

Figure 1 – Connector with pin-centre contact . 7
Figure 2 – Connector with socket-centre contact . 9
Figure 3 – Gauge pins for socket-centre contact . 9
Figure 4 – Connector with pin-centre contact . 11
Figure 5 – Connector with socket-centre contact . 13

Table 1 – Dimensions of connector with pin-centre contact . 8
Table 2 – Dimensions of connector with socket-centre contact . 10
Table 3 – Dimensions of gauge pins for socket-centre contact . 10
Table 4 – Dimensions of connector with pin-centre contact . 12
Table 5 – Dimensions of connector with socket-centre contact . 14
Table 6 – Rating and characteristics . 15
Table 7 – Acceptance tests . 17
Table 8 – Periodic tests . 18

---------------------- Page: 8 ----------------------

SIST EN 61169-42:2014
61169-42  IEC:2013(E) – 3 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________

RADIO-FREQUENCY CONNECTORS –

Part 42: Sectional specification for CQN series
quick lock RF coaxial connectors


FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
International Standard IEC 61169-42 has been prepared by subcommittee 46F: R.F. and
microwave passive components, of IEC technical committee 46: Cables, wires, waveguides,
R.F. connectors, R.F. and microwave passive components and accessories.
This first edition cancels and replaces the first edition of IEC/PAS 61169-42 published in 2009.
The text of this standard is based on the following documents:
CDV Report on voting
46F/142/CDV 46F/165/RVC

Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.

---------------------- Page: 9 ----------------------

SIST EN 61169-42:2014
– 4 – 61169-42  IEC:2013(E)
A list of all parts of the IEC 61169 series, under the general title: Radio-frequency connectors,
can be found on the IEC website.
The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.

IMPORTANT – The 'colour inside' logo on the cover page of this publication indicates
that it contains colours which are considered to be useful for the correct
understanding of its contents. Users should therefore print this document using a
colour printer.

A bilingual version of this publication may be issued at a later date.

---------------------- Page: 10 ----------------------

SIST EN 61169-42:2014
61169-42  IEC:2013(E) – 5 –
INTRODUCTION
The International Electrotechnical Commission (IEC) draws attention to the fact that it is
claimed that compliance with this document may involve the use of a patent concerning the
design of these connectors given in Subclause 3.1.
IEC takes no position concerning the evidence, validity and scope of this patent right.
The holder of this patent right has assured the IEC that he/she is willing to negotiate licences
under reasonable and non-discriminatory terms and conditions with applicants throughout the
world. In this respect, the statement of the holder of this patent right is registered with IEC.
Information may be obtained from:
Mr. Qu jinliang
Address: Room 302, Gudai road 1266–48,Ghanghai 201102 China (021-54148062).
Shaanxi huada S&T CO., LTD
Address: No.3 Dianzixijie Electronic Indusrtrial Park, Xi’an P.R China
HUADA is the trade name of Shaanxi huada S&T CO., LTD. This information is given for the
information of users of this standard and does not constitute an endorsement by IEC of the
trademark holder or any of its products. Compliance to this profile does not require use of the
trade name HUADA. Use of the trade name HUADA requires permission from Shaanxi huada
S&T CO., LTD
Attention is drawn to the possibility that some of the elements of this document may be the
subject of patent rights other than those identified above. IEC shall not be held responsible for
identifying any or all such patent rights.
ISO (www.iso.org/patents) and IEC (http://patents.iec.ch) maintain on-line data bases of
patents relevant to their standards. Users are encouraged to consult the data bases for the
most up to date information concerning patents.

---------------------- Page: 11 ----------------------

SIST EN 61169-42:2014
– 6 – 61169-42  IEC:2013(E)
RADIO-FREQUENCY CONNECTORS –

Part 42: Sectional specification for CQN series
quick lock RF coaxial connectors



1 Scope
This part of IEC 61169, which is a sectional specification (SS), provides information and rules
for the preparation of detail specifications (DS) for CQN series RF coaxial connectors, with
characteristic impedance of 50 Ω, with threaded coupling and operating frequency limit up to
11 GHz, used in wireless, microwave, telecommunication, and other fields, connecting with
RF cables or micro-strips.
It also prescribes mating face dimensions for general connectors-grade 2, dimensional details
of standard test connectors-grade 0, gauging information and tests selected from IEC 61169-1,
applicable to all detail specifications relating to CQN series connectors.
This specification indicates the recommended performance characteristics to be considered
when writing a detail specification and it covers test schedules and inspection requirements
for assessment levels M and H (see Tables 8 and 9).
This specification indicates the recommended performance characteristics to be considered
when writing a detail specification and it covers test schedules and inspection requirements
for assessment levels M and H.
2 Normative reference
The following documents, in whole or in part, are normatively referenced in this document and
are indispensable for its application. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any
amendments) applies.
IEC 61169-1:1992, Radio-frequency connectors – Part 1: Generic specification – General
1
requirements and measuring methods
Amendment 1:1996
Amendment 2:1997
3 Mating face and gauge information
3.1 Dimensions – General connectors – Grade 2
3.1.1 Connector with pin-centre contact
Metric dimension are original dimensions. All undimensioned pictorial configurations are for
reference purpose only.
_____________

1
There exists a consolidated edition 1.2 (1998) that comprises IEC 61169-1:1992, its Amendment 1:1996 and its
Amendment 2:1997.

---------------------- Page: 12 ----------------------

SIST EN 61169-42:2014
61169-42  IEC:2013(E) – 7 –

e
Note 1
Note 7(see detail I)
Note 2
Note 6
Note 6
p
r
m
g
h
Detail I
Note 3
j
n
IEC  095/13

Figure 1 – Connector with pin-centre contact
(for dimensions and notes, see Table 1)


∅k
∅f
∅a
∅b
∅c
∅d

---------------------- Page: 13 ----------------------

SIST EN 61169-42:2014
– 8 – 61169-42  IEC:2013(E)
Table 1 – Dimensions of connector with pin-centre contact
Ref. mm Additional
notes
Min. Max.
a 7,00 nominal (4)
b 9,05 —
c 10,05 —
d — 19,00
e — 9,80 (5)
f 1,60 1,68
g — 7,60
h 2,72 4,00
j 0,80 1,00
k — — (4)
m — 5,30
n 5,00 6,28
p — 2,40
r — 4,70
(1) Mechanical and electrical reference plane.
(2) Design and location of the seal ring is optional, providing it meets
environmental requirement.
(3) Radius or angle, plane part is 0,25 mm max.
(4) Diameters are chosen to obtain a normal impedance of
50 Ω and meet electrical and mechanical requirements.
(5) Prefix locknut (maximal dimension)
(6) Chamfer.
(7) Design of spring is optional, providing it meets mechanical
requirements performance.

---------------------- Page: 14 ----------------------

SIST EN 61169-42:2014
61169-42  IEC:2013(E) – 9 –
3.1.2 Connector with socket-centre contact

Note 1
i
h
g
f
50° ± 10°
30° ± 10°
Note 2
n
m
IEC  096/13

Figure 2 – Connector with socket-centre contact
(for dimensions and notes, see Table 2)
3.2 Gauges
3.2.1 Gauge pins for socket-centre contact

30°
∅a
R0,4 mm
R0,4 mm max.
IEC  097/13


Figure 3 – Gauge pins for socket-centre contact
(for dimensions, see Table 3)
∅e
∅d
∅c
∅j
∅b
∅k
∅a
b

---------------------- Page: 15 ----------------------

SIST EN 61169-42:2014
– 10 – 61169-42  IEC:2013(E)
Table 2 – Dimensions of connector with socket-centre contact
Ref. mm Additional
notes
Min. Max.
a 7,00 nominal (3)
b 8,30 8,50
c 8,70 8,90
d 8,90 9,00
e — 10
f 4,20 4,25
g 4,90 5,00
h 6,15 6,25
i 11,00 —
j — — (3)
k — — (2)
m 5,33 —
n 1,00 1,20
(1) Mechanical and electrical reference plane.
(2) Design of centre contact is optional, providing it meets electrical
and mechanical requirements.
(3) Diameters are chosen to obtain a normal impedance of 50 Ω and
meet electrical and mechanical requirements performance.

Table 3 – Dimensions of gauge pins for socket-centre contact
Gauge A Gauge B
maximum material for sizing purposes minimum material for
measurement of retention force
mass of gauge: 56 g ± 2 g
Ref. mm mm
Min. Max. Min. Max.
a 1,680 1,685 1,595 1,600
b 1,72 2,92 1,72 2,92
Material: steel, polished, surface roughness: Ra=0,4 µm maximum.

3.2.2 Test procedure
The gauge A shall be inserted into the socket-centre contact three times with a minimum
depth of 1,72 mm. This is a sizing operation and should only be carried out when the socket-
centre contact is removed from the connector.
After this, the gauge B shall be inserted into socket-centre contact. The contact shall retain
the mass of the gauge in a vertical downward position. The test also shall be carried out on
connector when the socket-centre contact is not removed.

---------------------- Page: 16 ----------------------

SIST EN 61169-42:2014
61169-42  IEC:2013(E) – 11 –
Additional test:
At the conclusion of the tests and if prescribed in the DS, the force necessary to insert gauge
A shall be measured. When this additional test is required, the force required shall not exceed
9,0 N.
3.3 Dimensions- standard test connectors – Grade 0
3.3.1 Connector with pin-centre contact

A
0,013mm
Note7(See detail I)
Note 1 e
Note 6
A
∅0,025 mm
Note 2
Note 6
A
p
r
m
g
∅0,025 mm A
h
B
∅0,013 mm
Note 3 Detail I
j
B
n
IEC  098/13

Figure 4 – Connector with pin-centre contact
(for dimensions and notes, see Table 4)

∅k
∅f
∅a
∅b
∅c
∅d

---------------------- Page: 17 ----------------------

SIST EN 61169-42:2014
– 12 – 61169-42  IEC:2013(E)
Table 4 – Dimensions of connector with pin-centre contact
Ref. mm Additional
notes
Min. Max.
a 7,00 nominal (4)
b 9,05 —
c 10,05 —
d — 19,00
e — 9,60 (5)
f 1,64 1,66
g — 7,50
h 3,00 3,80
j 0,90 1,00
k — — (4)
m — 5,30
n 5,30 6,00
p — 2,30
r — 4,60
(1) Mechanical and electrical reference plane, surface roughness:
Ra = 0,8 µm.
(2) Design and location of the seal ring is optional, but shall meet
environmental requirement performance.
(3) Radius or angle, plane part is 0,25 mm max.
(4) Diameters are chosen to obtain a characteristic impedance of
50 Ω ± 0,5 Ω.
(5) Prefix locknut (maximal dimension).
(6) Chamfer.
(7) Design of spring is optional, providing it meets mechanical
requirements performance.

---------------------- Page: 18 ----------------------

SIST EN 61169-42:2014
61169-42  IEC:2013(E) – 13 –
3.3.2 Connector with socket-centre contact

0,013 mm A
Note1
i
h
g
f
50° ± 10°
A 30° ± 10°
A
∅0,025 mm
B
∅0,013 mm
Note2
Note4
n
B
m
IEC  099/13

Figure 5 – Connector with socket-centre contact
(for dimensions and notes, see Table 5)


∅e
∅d
∅c
∅j
∅b
∅k
∅a

---------------------- Page: 19 ----------------------

SIST EN 61169-42:2014
– 14 – 61169-42  IEC:2013(E)
Table 5 – Dimensions of connector with socket-centre contact
Ref. mm Additional
notes
Min. Max.
a 7,00 nominal (3)
b 8,35  8,45
c 8,75 8,85
d 8,90 8,95
e — 10,00
f 4,20 4,25
g 4,90 4,95
h 6,15 6,20
i 11,00 —
j — — (3)
k    — — (4)
m 5,33 —
n 1,00 1,10
(1) Mechanical and electrical reference plane, surface roughness:
Ra = 0,8 µm.
(2) Remove flash carefully.
(3) Diameters are chosen to obtain a normal impedance of
50 Ω ± 0,5 Ω and meet electrical and mechanical requirements.
(4) Design of centre contact is optional, providing it meets electrical
and mechanical requirements.

4 Quality assessment procedure
4.1 General
Subclauses 4.2 to 4.4 provide recommended rating, performance and test conditions to be
considered when writing a detail specification. They also provide an appropriate schedule of
tests with minimum levels of conformance inspection sampling, together with the pro-forma
blank detail specification (BDS) and instructions for the preparation of a detail specification.
4.2 Rating and characteristics (see Clause 6 of IEC 61169-1:1992)
The values indicated below are recommended for CQN series RF connectors and are given
for the writer of the detail specification. They are applicable for the condition when the
connectors are fully mated.
Certain tests are listed without any recommended values being given. These tests will usually
not be required. When these tests are required, appropriate values shall be entered in the
detail specification at the discretion of the specification writer.

---------------------- Page: 20 ----------------------

SIST EN 61169-42:2014
61169-42  IEC:2013(E) – 15 –
Table 6 – Rating and characteristics
Remarks,
IEC 61169-1:1992 deviations from
Rating and characteristics Values
Subclause standard
test method
Electrical

Nominal impedance
50 Ω
Frequency range  DC to 11 GHz Or upper frequency
limit of cable


a
Reflection factor 9.2.1
General connectors  DC to 3 GHz:
- straight styles 0,07 max.
 3 GHz to 6 GHz
 0,09 max.
 6 GHz to 11 GHz
 0,13 max
- right-angle styles  See DS
- component mounting styles  See DS
- solder bucket and PCB mounting styles See DS
b
Centre contact resistance 9.2.3
- initial ≤1,0 mΩ
- after conditioning
≤1,5 mΩ
b
Outer conductor continuity 9.2.3
- initial ≤0,25 mΩ
- after conditioning
≤1,0 mΩ

Insulation resistance 9.2.5
- initial
≥5 000 MΩ
- after conditioning
≥200 M
c,d
Proof voltage at sea-level 9.2.6
- uncabled styles 2 500 V
- semi-rigid 0,141 in (3,58 mm) diameter  1 000 V
- semi-rigid 0,086 in (2,16 mm) diameter 750 V
c,d
Proof voltage at 4,4 kPa 9.2.6
- uncabled styles  450 V 4,4 kPa
approximately
- semi-rigid 0,141 in (3,58 mm) diameter  450 V
equivalent to 20 km
- semi-rigid 0,086 in (2,16 mm) diameter  180 V
c,d
Environmental test voltage at sea-level 9.2.6
- uncabled styles 1 000 V
- semi-rigid 0,141 in (3,58 mm) diameter 1 000 V
- semi-rigid 0,086 in (2,16 mm) diameter 400 V
c,d
Environmental test voltage at 4,4 kPa 9.2.6
- uncabled styles 200 V 4,4 kPa
approximately
- semi-rigid 0,141 in (3,58 mm) diameter  200 V
equivalent to 20 km
- semi-rigid 0,086 in (2,16 mm) diameter 90 V

---------------------- Page: 21 ----------------------

SIST EN 61169-42:2014
– 16 – 61169-42  IEC:2013(E)
Remarks,
IEC 61169-1:1992 deviations from
Rating and characteristics Values
Subclause standard
test method
Screening effectiveness (straight style 9.2.8
≥90 dB at 1 GHz
g
only)

Passive intermodulation  See DS
Discharge test (corona effect) 9.2.9 See DS Extinction voltage
Mechanical
Gauge retention force (resilient contacts)
- centre 9.3.4
≥0,56 N
Centre contact captivation  9.3.5 Maximum
displacement
- axial force  28 N
0,25 mm in each
direction

Engagement and separation 9.3.6 Can be carried out
≤30 N
by hand

Technical tests on cable fixing
- cable rotation (nutation) 9.3.7.2 See DS

- cable pulling 9.3.8 See DS
- cable bending 9.3.9 See DS
- cable torsion   9.3.10 See DS
Tensile strength of coupling mechanism 9.3.11
≥450 N
f
Bending moment 9.3.12 na
2
Vibration 9.3.3 100 m/s  10 g
n
10 Hz to 2 000 Hz

2
Shock 9.3.14 500 m/s 50 g
n
 1/2 sine wave
 11 ms
Environmental

Climatic category 9.4.2 A 55/125/21
B 40/085/21
Sealing non-hermetic 9.4.5.1 100 kPa to110 kPa
3
≤100 KPa·cm /h
differential
Hermetic 9.4.5.2 100 kPa to 110 kPa
–3 3
≤10 Pa·cm /s
differential
Salt mist 9.4.6 48 h spray
Endurance
Mechanical endurance 9.5 200 operations
e
High temper
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.