Thermal insulation products for buildings - Factory made products of expanded perlite (EPB) - Specification

This European Standard specifies the requirements for factory made products of expanded perlite, with or without facings or coatings, which are used for the thermal insulation of buildings. The products are manufactured in the form of boards or multi layered insulation.
This European Standard also covers composite insulation boards (see Annex D).
This European Standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.
Products covered by this European Standard are also used in prefabricated thermal insulating systems and composite panels; the performance of systems incorporating these products is not covered.
This European Standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non conflicting standards.
Products with a declared thermal resistance lower than 0,20 m2K/W or a declared thermal conductivity greater than 0,070 W/(mK) at 10 °C are not covered by this European Standard.
This European Standard does not cover in situ insulation products and products intended to be used for the insulation of building equipment and industrial installations. This European Standard does not cover the following acoustical aspects: Acoustic absorption index and direct airborne sound insulation.

Wärmedämmstoffe für Gebäude - Werkmäßig hergestellte Produkte aus Blähperlit (EPB) - Spezifikation

Diese Europäische Norm legt die Anforderungen für werkmäßig hergestellte Produkte aus Blähperlit mit oder ohne Kaschierung fest, die für die Wärmedämmung von Gebäuden benutzt werden. Die Produkte werden in der Form von Platten oder mehrlagigen Dämmplatten hergestellt.
Diese Europäische Norm umfasst auch Mehrschicht Dämmplatten (siehe Anhang D).
Diese Europäische Norm beschreibt die Stoffeigenschaften und enthält die Prüfverfahren und Festlegungen für die Konformitätsbewertung, die Kennzeichnung und die Etikettierung.
In dieser Europäischen Norm beschriebene Produkte werden auch in vorgefertigten Wärmedämmsystemen und Mehrschicht Verbundplatten angewendet; die Eigenschaften von Systemen, in die diese Produkte integriert sind, werden nicht behandelt.
Diese Europäische Norm legt keine Anforderungsniveaus für eine vorgegebene Eigenschaft fest, die ein Produkt erreichen muss, um für einen bestimmten Anwendungsfall tauglich zu sein. Für bestimmte Anwendungen benötigte Anforderungen können Regelwerken oder übereinstimmenden Normen entnommen werden.
Diese Europäische Norm gilt nicht für Produkte, deren Nennwert des Wärmedurchlasswiderstandes kleiner ist als 0,20 m2  K/W oder deren Nennwert der Wärmeleitfähigkeit größer ist als 0,070 W/(m  K) bei 10 °C.
Diese Europäische Norm gilt nicht für Ortsprodukte und für Produkte, die zur Dämmung von haustechnischen oder betriebstechnischen Anlagen bestimmt sind. Diese Norm gilt nicht für die folgenden Schallschutzaspekte: Schallabsorptionsgrad und direkte Luftschalldämmung.

Produits isolants thermiques pour le bâtiment - Produits manufacturés en perlite expansée (EPB) - Spécification

La présente Norme européenne spécifie les exigences auxquelles doivent satisfaire les produits manufacturés en perlite expansée, avec ou sans parements ou enduits, utilisés pour l’isolation thermique des bâtiments. Les produits sont fabriqués sous forme de panneaux ou d’isolation multicouche.
La présente norme concerne également les panneaux d’isolation composite (voir Annexe D).
La présente norme décrit les caractéristiques du produit et inclut les procédures d’essai, d’évaluation de la conformité, de marquage et d’étiquetage.
Les produits du domaine d'application de la présente norme sont également utilisés dans des systèmes d’isolation thermique et dans des panneaux composites préfabriqués; la performance des systèmes dans lesquels entrent ces produits n’est pas définie.
La présente norme ne spécifie pas, pour une propriété donnée, le niveau exigé que doit atteindre un produit pour démontrer son aptitude à l’emploi dans une application particulière. Les niveaux requis pour une application donnée figurent dans les réglementations, ou normes non conflictuelles.
Les produits dont la résistance thermique déclarée à une température de 10 °C est inférieure à 0,20 m2 .K/W ou dont la conductivité thermique déclarée à une température de 10 °C est supérieure à 0,070 W/(mK) ne sont pas du domaine d'application de la présente norme.
Les produits mis en œuvre in situ et ceux destinés à être utilisés pour l’isolation des équipements du bâtiment et des installations industrielles ne sont pas du domaine d'application de la présente norme. La présente norme ne couvre pas l'indice d'affaiblissement acoustique ni l’isolement aux bruits aériens directs.

Toplotnoizolacijski proizvodi za stavbe - Proizvodi iz ekspandiranega perlita (EPB) - Specifikacija

General Information

Status
Withdrawn
Public Enquiry End Date
30-Jul-2008
Publication Date
13-Jan-2009
Withdrawal Date
15-Jan-2013
Technical Committee
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
13-Dec-2012
Due Date
05-Jan-2013
Completion Date
16-Jan-2013

Relations

Buy Standard

Standard
EN 13169:2009
English language
45 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day
Draft
k prEN 13169:2008
English language
43 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Toplotnoizolacijski proizvodi za stavbe - Proizvodi iz ekspandiranega perlita (EPB) - SpecifikacijaWärmedämmstoffe für Gebäude - Werkmäßig hergestellte Produkte aus Blähperlit (EPB) - SpezifikationProduits isolants thermiques pour le bâtiment - Produits manufacturés en perlite expansée (EPB) - SpécificationThermal insulation products for buildings - Factory made products of expanded perlite (EPB) - Specification91.100.60Thermal and sound insulating materialsICS:Ta slovenski standard je istoveten z:EN 13169:2008SIST EN 13169:2009en,fr,de01-februar-2009SIST EN 13169:2009SLOVENSKI
STANDARDSIST EN 13169:2002/AC:2006SIST EN 13169:2002/A1:2004SIST EN 13169:20021DGRPHãþD



SIST EN 13169:2009



EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 13169November 2008ICS 91.100.60Supersedes EN 13169:2001
English VersionThermal insulation products for buildings - Factory madeproducts of expanded perlite (EPB) - SpecificationProduits isolants thermiques pour le bâtiment - Produitsmanufacturés en perlite expansée (EPB) - SpécificationWärmedämmstoffe für Gebäude - Werkmäßig hergestellteProdukte aus Blähperlit (EPB) - SpezifikationThis European Standard was approved by CEN on 18 October 2008.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2008 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 13169:2008: ESIST EN 13169:2009



EN 13169:2008 (E) 2 Contents Page Foreword .4 1 Scope .6 2 Normative references .6 3 Terms, definitions, symbols, units and abbreviated terms .8 4 Requirements . 11 5 Test methods . 16 6 Designation code . 20 7 Evaluation of conformity . 20 8 Marking and labelling . 21 Annex A (normative)
Determination of the declared values of thermal resistance and
thermal conductivity . 22 Annex B (normative)
Factory production control . 24 Annex C (normative)
Determination of the thermal conductivity in relation to moisture content . 27 Annex D (normative)
Composite insulation boards . 29 Annex E (informative)
Additional properties . 35 Annex ZA (informative)
Clauses of this European Standard addressing the provisions of the EU Construction Products Directive. 37 Bibliography . 45
Tables Table 1 — Thickness tolerances . 12 Table 2 — Levels for compressive stress or compressive strength . 14 Table 3 — Levels for deformation under specified compressive load and temperature . 14 Table 4 — Levels for water absorption by total immersion. 15 Table 5 — Levels for bending strength at constant span. 15 Table 6 — Test methods, test specimens and conditions. 19 Table A.1 — Values for k for one sided 90 % tolerance interval with a confidence level of 90 % . 23 Table B.1 — Minimum product testing frequencies . 24 Table B.2 — Minimum product testing frequencies for the reaction to fire characteristics . 25 Table D.1 — Classes for thickness tolerances . 30 Table D.2 — Levels of compressibility . 30 Table D.3 — Test methods, test specimens and conditions . 32 Table D.4 — Minimum product testing frequencies . 33 Table E.1 — Test methods, test specimens, conditions and testing frequencies . 36 Table ZA.1 — Relevant clauses for expanded perlite and intended use . 38 SIST EN 13169:2009



EN 13169:2008 (E) 3 Table ZA.2 — Systems of attestation of conformity . 39 Table ZA.3 — Assignment of evaluation of conformity tasks for products under system 1 . 40 Table ZA.4 — Assignment of evaluation of conformity tasks for products under system 3 or system 3 combined with system 4 for reaction to fire . 41
Figures Figure C.1 — Example of a graphic representation of “a”
(a = 0,04/0,037 = 1,08 in this example) . 28 Figure ZA.1 — Example CE marking information . 44
SIST EN 13169:2009



EN 13169:2008 (E) 4 Foreword This document (EN 13169:2008) has been prepared by Technical Committee CEN/TC 88 “Thermal insulating materials and products”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by May 2009, and conflicting national standards shall be withdrawn at the latest by May 2009. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EC Directive(s). For relationship with EC Directive(s), see informative Annex ZA, which is an integral part of this document. This document supersedes EN 13169:2001. This document is one of a series of standards for insulation products used in buildings, but this standard may be used in other areas where appropriate. In pursuance of Resolution BT 20/1993 Revised, CEN/TC 88 have proposed defining the standards listed below as a package of documents. The package of standards comprises the following group of interrelated standards for the specifications of factory made thermal insulation products, all of which come within the scope of CEN/TC 88: EN 13162, Thermal insulation products for buildings — Factory made mineral wool (MW) products — Specification EN 13163, Thermal insulation products for buildings — Factory made products of expanded polystyrene (EPS) — Specification EN 13164, Thermal insulation products for buildings — Factory made products of extruded polystyrene foam (XPS) — Specification EN 13165, Thermal insulation products for buildings — Factory made rigid polyurethane foam (PUR) products — Specification EN 13166, Thermal insulation products for buildings — Factory made products of phenolic foam (PF) — Specification EN 13167, Thermal insulation products for buildings — Factory made cellular glass (CG) products — Specification EN 13168, Thermal insulation products for buildings — Factory made wood wool (WW) products — Specification EN 13169, Thermal insulation products for buildings — Factory made products of expanded perlite (EPB) — Specification EN 13170, Thermal insulation products for buildings — Factory made products of expanded cork (ICB) — Specification SIST EN 13169:2009



EN 13169:2008 (E) 5 EN 13171, Thermal insulation products for buildings — Factory made wood fibre (WF) products — Specification According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom.
SIST EN 13169:2009



EN 13169:2008 (E) 6 1 Scope This European Standard specifies the requirements for factory made products of expanded perlite, with or without facings or coatings, which are used for the thermal insulation of buildings. The products are manufactured in the form of boards or multi-layered insulation. This European Standard also covers composite insulation boards (see Annex D). This European Standard specifies product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling. Products covered by this European Standard are also used in prefabricated thermal insulating systems and composite panels; the performance of systems incorporating these products is not covered. This European Standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non-conflicting standards. Products with a declared thermal resistance lower than 0,20 m2⋅K/W or a declared thermal conductivity greater than 0,070 W/(m⋅K) at 10 °C are not covered by this European Standard. This European Standard does not cover in situ insulation products and products intended to be used for the insulation of building equipment and industrial installations. This European Standard does not cover the following acoustical aspects: Acoustic absorption index and direct airborne sound insulation. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
EN 822, Thermal insulating products for building applications — Determination of length and width EN 823, Thermal insulating products for building applications — Determination of thickness EN 824, Thermal insulating products for building applications — Determination of squareness EN 825, Thermal insulating products for building applications — Determination of flatness EN 826, Thermal insulating products for building applications — Determination of compression behaviour EN 1602, Thermal insulating products for building applications — Determination of the apparent density
EN 1604, Thermal insulating products for building applications — Determination of dimensional stability under specified temperature and humidity conditions EN 1605, Thermal insulating products for building applications — Determination of deformation under specified compressive load and temperature conditions EN 1606, Thermal insulating products for building applications — Determination of compressive creep EN 1607, Thermal insulating products for building applications — Determination of tensile strength perpendicular to faces EN 1609, Thermal insulating products for building applications — Determination of short term water absorption by partial immersion SIST EN 13169:2009



EN 13169:2008 (E) 7 EN 12086:1997, Thermal insulating products for building applications — Determination of water vapour transmission properties EN 12089, Thermal insulating products for building applications — Determination of bending behaviour EN 12430, Thermal insulating products for building applications — Determination of behaviour under point load EN 12431, Thermal insulating products for building applications — Determination of thickness for floating floor insulating products EN 12667, Thermal performance of building materials and products — Determination of thermal resistance by means of guarded hot plate and heat flow meter methods – Products of high and medium thermal resistance EN 12939, Thermal performance of building materials and products — Determination of thermal resistance by means of guarded hot plate and heat flow meter methods — Thick products of high and medium thermal resistance EN 13172:2008, Thermal insulating products — Evaluation of conformity1 EN 13501-1, Fire classification of construction products and building elements — Part 1: Classification using data from reaction to fire test EN 13820, Thermal insulating materials for building applications — Determination of organic content EN 13823, Reaction to fire tests for building products — Building products excluding floorings exposed to the thermal attack by a single burning item EN 29052-1, Acoustics — Determination of dynamic stiffness — Part 1: Materials used under floating floors in dwellings EN ISO 354, Acoustics — Measurement of sound absorption in a reverberation room (ISO 354:2003) EN ISO 1182, Reaction to fire tests for building products — Non-combustibility test (ISO 1182:2002) EN ISO 1716, Reaction to fire tests for building products — Determination of the heat of combustion (ISO 1716:2002)
EN ISO 9229, Thermal insulation — Vocabulary (ISO 9229:2007) EN ISO 11654, Acoustics — Sound absorbers for use in buildings — Rating of sound absorption (ISO 11654:1997) EN ISO 11925-2, Reaction to fire tests — Ignitability of building products subjected to direct impingement of flame – Part 2: Single-flame source test (ISO 11925-2:2002) ISO 12491, Statistical methods for quality control of building materials and components
1 Under review SIST EN 13169:2009



EN 13169:2008 (E) 8
3 Terms, definitions, symbols, units and abbreviated terms 3.1 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1.1 Terms and definitions as given in EN ISO 9229 3.1.1.1 expanded perlite lightweight granular (insulation) material manufactured from naturally occurring volcanic rock expanded by heat to form a cellular structure 3.1.1.2 multi-layered insulation combination of two or more layers of a specific insulation material. The thickness of the individual layers may differ 3.1.1.3 composite insulation combination of layers of at least two different insulation materials. The insulation property of the composite is derived from the insulation properties of the individual materials 3.1.2 Additional terms and definitions 3.1.2.1 expanded perlite board rigid insulation board manufactured from expanded perlite, reinforcing fibres and binding agents NOTE 1 It may be delivered as a board or as two or more boards bonded together with a suitable adhesive (multi-layered insulation: see 3.1.1.2).
NOTE 2 Boards may also have a profiled edge. 3.1.2.2 level given value which is the upper or lower limit of a requirement. The level is given by the declared value of the characteristic concerned 3.1.2.3 class combination of two levels of the same property between which the performance shall fall 3.2 Symbols units and abbreviated terms 3.2.1 Symbols and units used in this standard: a is the coefficient describing the influence of moisture on the thermal conductivity – b is the width mm c is the compressibility mm d is the thickness mm SIST EN 13169:2009



EN 13169:2008 (E) 9 dB is the thickness under a load of 2 kPa after removal of an additional load of 48 kPa mm dL is the thickness under a load of 250 Pa mm dN is the nominal thickness of the product mm ∆εb is the relative change in width % ∆εd is the relative change in thickness % ∆εl is the relative change in length % k is a factor related to the number of test results available – l is the length mm λD is the declared thermal conductivity W/(m⋅K) λi is one test result of thermal conductivity W/(m⋅K) λmean is the mean thermal conductivity W/(m⋅K) λ10,dry is the thermal conductivity in the dry state W/(m⋅K) λ90/90 is the 90 % fractile with a confidence level of 90 % for the thermal conductivity W/(m⋅K) m1 is the mass of the test specimen after 2 h total immersion in water kg m23,dry is the mass of specimen in the dry state kg m23,50 is the mass of specimen at 23 °C and 50 % relative humidity kg µ is the water vapour diffusion resistance factor – n is the number of test results – RD is the declared thermal resistance m2⋅K/W Ri is one test result of thermal resistance m2⋅K/W Rmean is the mean thermal resistance m2⋅K/W R90/90 is the 90 % fractile with a confidence level of 90 % for the thermal resistance m2⋅K/W Sb is the deviation from squareness on length and width mm/m Smax is the deviation from flatness mm sR is the estimate of the standard deviation of the thermal resistance m2⋅K/W sλ is the estimate of the standard deviation of the thermal conductivity W/(m⋅K) s′ is the dynamic stiffness MN/m3σb is the bending strength kPa σbc is the bending strength at a constant span kPa σc is the declared compressive stress kPa σm is the compressive strength kPa σmt is the tensile strength perpendicular to faces kPa σ10 is the compressive stress at 10 % deformation kPa u23,50 is the moisture content by mass at 23 °C and 50 % relative humidity kg/kg SIST EN 13169:2009



EN 13169:2008 (E) 10 V is the volume of the specimen m3 Wp is the short-term water absorption by partial immersion kg/m2 Wst is the short-term water absorption by total immersion kg/dm3 X0 is the initial deformation after 60 s from the beginning of loading mm Xct is the compressive creep mm Xt is the deformation at time t (total thickness reduction) mm Z is the water vapour resistance m2⋅h⋅Pa/mg BS is the symbol of the declared level of bending strength BS(z) is the symbol of the declared level of bending strength at a constant span CC(i1/i2/y)σc is the symbol of the declared level for compressive creep* CP is the symbol of the declared level for compressibility CS(10\Y)i is the symbol of the declared level for compressive stress or compressive strength* DLT(i)5 is the symbol of the declared level of deformation under load and temperature DS(H) is the symbol of the declared value for dimensional stability under humidity condition DS(T+/50) is the symbol of the declared value for dimensional stability under specified temperatureand humidity MUi is the symbol of the declared value for water vapour diffusion resistance factor* PL(2)i is the symbol of the declared level of point load for 2 mm deformation* SD is the symbol of the declared level of dynamic stiffness T is the symbol of the declared class for thickness tolerances TRi is the symbol of the declared value for tensile strength perpendicular to faces* WS is the symbol of the declared level for short term water absorption absorption by partialimmersion WS(T) is the symbol of the declared level of short term water absorption by total immersion Zi is the symbol of the declared value for water vapour resistance* * "i” is the relevant class or level, "1c” is the compressive stress, and "y” is the number of years 3.2.2 Abbreviated terms used in this standard: EPB Expanded Perlite Board ITT
Initial Type Test RTF Reaction To Fire FPC Factory Production Control SIST EN 13169:2009



EN 13169:2008 (E) 11 4 Requirements 4.1 General Product properties shall be assessed in accordance with clause 5. To comply with this standard, products shall meet the requirements of 4.2, and the requirements of 4.3 as appropriate. NOTE Information on additional properties is given in Annex E. One test result on a product property is the average of the measured values on the number of test specimens given in Table 6. 4.2 For all applications 4.2.1 Thermal resistance and thermal conductivity Thermal resistance and thermal conductivity shall be based upon measurements carried out in accordance with EN 12667 or EN 12939 for thick products. The thermal resistance and thermal conductivity shall be determined in accordance with Annex A and Annex C, and declared by the manufacturer according to the following:  the reference mean temperature shall be 10 °C;  the measured values shall be expressed with three significant figures;  for products of uniform thickness, the thermal resistance, RD, shall always be declared. The thermal conductivity, λD, shall be declared where possible. Where appropriate, for products of non-uniform thickness (e.g. for sloped and tapered products) only the thermal conductivity, λD, shall be declared.  the declared thermal resistance, RD, and thermal conductivity, λD, shall be given as limit values representing at least 90 % of the production, determined with a confidence level of 90 %;  the value of thermal conductivity, λ90/90, shall be rounded upwards to the nearest 0,001 W/(m⋅K) and declared as λD in levels with steps of 0,001 W/(m⋅K);  the declared thermal resistance, RD, shall be calculated from the nominal thickness, dN, and the corresponding thermal conductivity, λ90/90;  the value of thermal resistance, R90/90, when calculated from the nominal thickness, dN, and the corresponding thermal conductivity, λ90/90, shall be rounded downwards to the nearest 0,05 m2⋅K/W, and declared as RD in levels with steps of 0,05 m2⋅K/W;  the value of R90/90, for those products for which only thermal resistance is measured directly, shall be rounded downwards to the nearest 0,05 m2 K/W, and declared as RD in levels with steps of 0,05 m2⋅K/W. 4.2.2 Length and width Length, l, and width, b, shall be determined in accordance with EN 822. No test result shall deviate from the nominal values by more than the following: ± 3 mm for length and width not exceeding 1 200 mm; SIST EN 13169:2009



EN 13169:2008 (E) 12 ± 5 mm for length and width exceeding 1 200 mm. In the case of bonded boards, the offset on the edges shall not exceed 3 mm.
4.2.3 Thickness Thickness, d, shall be determined in accordance with EN 823, using a load equal to 250 Pa. No test result shall deviate from the nominal thickness, dN, by more than the corresponding tolerances given in Table 1. Table 1 — Thickness tolerances Dimensions in millimetres Nominal thickness dN ≤ 35 35 < dN ≤ 70 70 < dN ≤ 120 dN > 120 Tolerance ± 1 ± 2 ± 3 ± 4
This test shall not be performed when the tests described in D.2.7 are used. 4.2.4 Squareness Squareness shall be determined in accordance with EN 824. The deviation from squareness on length and width, Sb, shall not exceed 3 mm/m. 4.2.5 Flatness Flatness shall be determined in accordance with EN 825. The deviation from flatness, Smax, shall not exceed the following: 3 mm for length and width not exceeding 1 200 mm; 5 mm for length and width exceeding 1 200 mm. 4.2.6 Bending strength Bending strength, σb, shall be determined in accordance with EN 12089. For handling purpose, the bending strength of boards shall not be less than 250 kPa. NOTE The requirement for handling applies to individual boards. In the case of multi-layered boards, it may be assumed that the requirement is satisfied when each of the individual layers fulfills this requirement. 4.2.7 Dimensional stability under specified temperature and humidity conditions Dimensional stability under specified humidity conditions shall be determined in accordance with EN 1604. The test shall be carried out for 48 h at (23 ± 2) °C and (90 ± 5) % relative humidity. The relative changes in length, ∆εl, and width, ∆εb, shall not exceed 0,5 %. The relative changes in thickness, ∆εd, shall not exceed 1 %. 4.2.8 Reaction to fire Reaction to fire classification (Euroclasses) shall be determined in accordance with EN 13501-1. SIST EN 13169:2009



EN 13169:2008 (E) 13 4.2.9 Durability characteristics 4.2.9.1 General The appropriate durability characteristics have been considered and are covered in 4.2.9.2, 4.2.9.3 and 4.2.9.4. 4.2.9.2 Durability of reaction to fire against ageing/ degradation The reaction to fire performance of factory made products of expanded perlite does not change with time. 4.2.9.3 Durability of thermal resistance against ageing/ degradation The thermal conductivity of factory made products of expanded perlite does not change with time. This is covered by 4.2.1 thermal conductivity, 4.2.2 Length and width and 4.2.7 Dimensional stability or 4.3.2 Dimensional stability. 4.2.9.4 Durability of compressive strength against ageing/degradation The durability of compressive strength is covered by 4.3.9 Compressive creep. 4.3 For specific applications 4.3.1 General If there is no requirement for a property described in 4.3 for a product in use, then the property does not need to be determined and declared by the manufacturer. 4.3.2 Dimensional stability under specified temperature and humidity conditions Dimensional stability under specified temperature conditions shall be determined in accordance with EN 1604. The test shall be carried out for 48 h exposure at (70 ± 2) °C and (50 ± 5) % relative humidity. The relative changes in length, ∆εl, and width, ∆εb, shall not exceed 0,5 %. The relative changes in thickness, ∆εd, shall not exceed 1 %. 4.3.3 Compressive stress or compressive strength Compressive stress at 10 % deformation, σ10, or the compressive strength, σm, shall be determined in accordance with EN 826. No test result for either the compressive stress at 10 % deformation, σ10, or the compressive strength, σm, whichever is the smaller, shall be less than the value given in Table 2, for the declared level. SIST EN 13169:2009



EN 13169:2008 (E) 14
Table 2 — Levels for compressive stress or compressive strength Level Requirement kPa CS(10\Y)100 ≥ 100 CS(10\Y)125 ≥ 125 CS(10\Y)150 ≥ 150 CS(10\Y)200 ≥ 200 CS(10\Y)300 ≥ 300 CS(10\Y)450 ≥ 450 CS(10\Y)700 ≥ 700 CS(10\Y)800 ≥ 800
4.3.4 Deformation under specified load and temperature Deformation in thickness under specified load and temperature conditions shall be determined in accordance with EN 1605. The relative deformation in thickness, ∆εd, shall not exceed the values given in Table 3 for the declared level. Table 3 — Levels for deformation under specified compressive load and temperature Level Requirement % Test conditions DLT(1)5 ≤ 5 Load: 20 kPa Temperature: (80 ± 1) °C Time: (48 ± 1) h DLT(2)5 ≤ 5 Load: 40 kPa Temperature: (70 ± 1) °C Time: (168 ± 1) h DLT(3)5 ≤ 5 Load: 80 kPa Temperature: (60 ± 1) °C Time: (168 ± 1) h
4.3.5 Tensile strength perpendicular to faces Tensile strength perpendicular to faces, σmt, shall be determined in accordance with EN 1607, using the additional provisions of 5.3.3. No test result shall be lower than 20 kPa. 4.3.6 Water absorption 4.3.6.1 Short-term water absorption by partial immersion Short-term water absorption by partial immersion, Wp, shall be determined in accordance with EN 1609. No test result shall exceed the declared value. SIST EN 13169:2009



EN 13169:2008 (E) 15 4.3.6.2 Short-term water absorption by total immersion Short-term water absorption by total immersion, Wst, shall be determined in accordance with 5.3.4. No test result shall exceed the value, given in Table 4, for the declared level. Table 4 — Levels for water absorption by total immersion Level Requirement kg/dm3 WS(T) 8 ≤ 0,08 WS(T) 6 ≤ 0,06 WS(T) 4 ≤ 0,04 WS(T) 2 ≤ 0,02
4.3.7 Bending strength at a constant span Bending strength at a constant span of 250 mm, σbc, shall be determined in accordance with EN 12089. No test result shall be lower than the value given in Table 5, for the declared
...

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Thermal insulation products for buildings - Factory made products of expanded perlite (EPB) - SpecificationToplotnoizolacijski proizvodi za stavbe - Proizvodi iz ekspandiranega perlita (EPB) - SpecifikacijaProduits isolants thermiques pour le bâtiment - Produits manufacturés en perlite expansée (EPB) - SpécificationWärmedämmstoffe für Gebäude - Werkmäßig hergestellte Produkte aus Blähperlit (EPB) - Spezifikation91.100.60Thermal and sound insulating materialsICS:kSIST prEN 13169:2008en,deTa slovenski standard je istoveten z:prEN 1316901-junij-2008kSIST prEN 13169:2008SLOVENSKI
STANDARD







EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMFINAL DRAFTprEN 13169April 2008ICS 91.100.60Will supersede EN 13169:2001
English VersionThermal insulation products for buildings - Factory madeproducts of expanded perlite (EPB) - SpecificationProduits isolants thermiques pour le bâtiment - Produitsmanufacturés en perlite expansée (EPB) - SpécificationWärmedämmstoffe für Gebäude - Werkmäßig hergestellteProdukte aus Blähperlit (EPB) - SpezifikationThis draft European Standard is submitted to CEN members for unique acceptance procedure. It has been drawn up by the TechnicalCommittee CEN/TC 88.If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations whichstipulate the conditions for giving this European Standard the status of a national standard without any alteration.This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other languagemade by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has thesame status as the official versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without notice andshall not be referred to as a European Standard.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2008 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. prEN 13169:2008: E



prEN 13169:2008 (E) 2 Contents Page Foreword.4 1 Scope.5 2 Normative references.5 3 Terms, definitions, symbols, units and abbreviated terms.7 4 Requirements.9 5 Test methods.15 6 Designation code.18 7 Evaluation of conformity.18 8 Marking and labelling.19 Annex A (normative)
Determination of the declared values of thermal resistance and
thermal conductivity.20 Annex B (normative)
Factory production control.22 Annex C (normative)
Determination of the thermal conductivity in relation to moisture content.25 Annex D (normative)
Composite insulation boards.27 Annex E (informative)
Additional properties.33 Annex ZA (informative)
Clauses of this European Standard addressing the provisions of the EU Construction Products Directive.35 Bibliography.43
Tables Table 1 — Thickness tolerances.11 Table 2 — Levels for compressive stress or compressive strength.12 Table 3 — Levels for deformation under specified compressive load and temperature.13 Table 4 — Levels for water absorption by total immersion.13 Table 5 — Levels for bending strength at constant span.14 Table 6 — Test methods, test specimens and conditions.17 Table A.1 — Values for k for one sided 90 % tolerance interval with a confidence level of 90 %.21 Table B.1 — Minimum product testing frequencies.22 Table B.2 — Minimum product testing frequencies for the reaction to fire characteristics.23 Table D.1 — Classes for thickness tolerances.28 Table D.2 — Levels of compressibility.28 Table D.3 — Test methods, test specimens and conditions.30 Table D.4 — Minimum product testing frequencies.31 Table E.1 — Test methods, test specimens, conditions and testing frequencies.34 Table ZA.1 — Relevant clauses for expanded perlite and intended use.36



prEN 13169:2008 (E) 3 Table ZA.2 — Systems of attestation of conformity.37 Table ZA.3 — Assignment of evaluation of conformity tasks for products under system 1.38 Table ZA.4 — Assignment of evaluation of conformity tasks for products under system 3 or system 3 combined with system 4 for reaction to fire.39
Figures Figure C.1 — Example of a graphic representation of “a”
(a = 0,04/0,037 = 1,08 in this example).26 Figure ZA.1 — Example CE marking information.42



prEN 13169:2008 (E) 4 Foreword This document (prEN 13169:2008) has been prepared by Technical Committee CEN/TC 88 “Thermal insulating materials and products”, the secretariat of which is held by DIN. This document is currently submitted to the Unique Acceptance Procedure. This document will supersede EN 13169:2001. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EC Directive(s). For relationship with EC Directive(s), see informative Annex ZA, which is an integral part of this document. This document is one of a series of standards for insulation products used in buildings, but this standard may be used in other areas where appropriate. In pursuance of Resolution BT 20/1993 Revised, CEN/TC 88 have proposed defining the standards listed below as a package of documents. The package of standards comprises the following group of interrelated standards for the specifications of factory made thermal insulation products, all of which come within the scope of CEN/TC 88: EN 13162, Thermal insulation products for buildings — Factory made mineral wool (MW) products — Specification EN 13163, Thermal insulation products for buildings — Factory made products of expanded polystyrene (EPS) — Specification EN 13164, Thermal insulation products for buildings — Factory made products of extruded polystyrene foam (XPS) — Specification EN 13165, Thermal insulation products for buildings — Factory made rigid polyurethane foam (PUR) products — Specification EN 13166, Thermal insulation products for buildings — Factory made products of phenolic foam (PF) — Specification EN 13167, Thermal insulation products for buildings — Factory made cellular glass (CG) products — Specification EN 13168, Thermal insulation products for buildings — Factory made wood wool (WW) products — Specification EN 13169, Thermal insulation products for buildings — Factory made products of expanded perlite (EPB) — Specification EN 13170, Thermal insulation products for buildings — Factory made products of expanded cork (ICB) — Specification EN 13171, Thermal insulation products for buildings — Factory made wood fibre (WF) products — Specification



prEN 13169:2008 (E) 5 1 Scope This European Standard specifies the requirements for factory made products of expanded perlite, with or without facings or coatings, which are used for the thermal insulation of buildings. The products are manufactured in the form of boards or multi-layered insulation. This European Standard also covers composite insulation boards (see Annex D). This European Standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling. Products covered by this European Standard are also used in prefabricated thermal insulating systems and composite panels; the performance of systems incorporating these products is not covered. This European Standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non-conflicting standards. Products with a declared thermal resistance lower than 0,20 m2⋅K/W or a declared thermal conductivity greater than 0,070 W/(m⋅K) at 10 °C are not covered by this European Standard. This European Standard does not cover in situ insulation products and products intended to be used for the insulation of building equipment and industrial installations. This European Standard does not cover the following acoustical aspects: Acoustic absorption index and direct airborne sound insulation. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
EN 822, Thermal insulating products for building applications — Determination of length and width EN 823, Thermal insulating products for building applications — Determination of thickness EN 824, Thermal insulating products for building applications — Determination of squareness EN 825, Thermal insulating products for building applications — Determination of flatness EN 826, Thermal insulating products for building applications — Determination of compression behaviour EN 1602, Thermal insulating products for building applications — Determination of apparent density
EN 1604, Thermal insulating products for building applications — Determination of dimensional stability under specified temperature and humidity conditions EN 1605, Thermal insulating products for building applications — Determination of deformation under specified compressive load and temperature conditions EN 1606, Thermal insulating products for building applications — Determination of compressive creep EN 1607, Thermal insulating products for building applications — Determination of tensile strength perpendicular to faces EN 1609, Thermal insulating products for building applications — Determination of short term water absorption by partial immersion



prEN 13169:2008 (E) 6 EN 12086:1997, Thermal insulating products for building applications — Determination of water vapour transmission properties EN 12089, Thermal insulating products for building applications — Determination of bending behaviour EN 12430, Thermal insulating products for building applications — Determination of behaviour under point load EN 12431, Thermal insulating products for building applications — Determination of thickness for floating floor insulating products EN 12667, Thermal performance of building materials and products — Determination of thermal resistance by means of guarded hot plate and heat flow meter methods – Products of high and medium thermal resistance EN 12939, Thermal performance of building materials and products — Determination of thermal resistance by means of guarded hot plate and heat flow meter methods — Thick products of high and medium thermal resistance EN 13172:2001, Thermal insulating products — Evaluation of conformity1 EN 13501-1, Fire classification of construction products and building elements — Part 1: Classification using test data from reaction to fire test EN 13820, Thermal insulating materials for building applications — Determination of organic content EN 13823, Reaction to fire tests for building products — Building products excluding floorings exposed to the thermal attack by a single burning item EN 29052-1, Acoustics — Determination of dynamic stiffness — Part 1: Materials used under floating floors in dwellings EN ISO 354, Acoustics — Measurement of sound absorption in a reverberation room (ISO 354:2003) EN ISO 1182, Reaction to fire tests for building products — Non-combustibility test (ISO 1182:2002) EN ISO 1716, Reaction to fire tests for building products — Determination of the heat of combustion (ISO 1716:2002)
EN ISO 9229, Thermal insulation — Vocabulary (ISO 9229:2007) EN ISO 11654, Acoustics — Sound absorbers for use in buildings — Rating of sound absorption (ISO 11654:1997) EN ISO 11925-2, Reaction to fire tests for building products — Ignitability of building products subjected to direct impingement of flame – Part 2: Single-flame source test (ISO 11925-2:2002) ISO 12491, Statistical methods for quality control of building materials and components
1 Under review



prEN 13169:2008 (E) 7
3 Terms, definitions, symbols, units and abbreviated terms 3.1 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1.1 Terms and definitions as given in EN ISO 9229:2007 3.1.1.1 expanded perlite lightweight granular (insulation) material manufactured from naturally occurring volcanic rock expanded by heat to form a cellular structure 3.1.1.2 multi-layered insulation combination of two or more layers of a specific insulation material. The thickness of the individual layers may differ 3.1.1.3 composite insulation combination of layers of at least two different insulation materials. The insulation property of the composite is derived from the insulation properties of the individual materials 3.1.2 Additional terms and definitions 3.1.2.1 expanded perlite board rigid insulation board manufactured from expanded perlite, reinforcing fibres and binding agents NOTE 1 It may be delivered as a board or as two or more boards bonded together with a suitable adhesive (multi-layered insulation: see 3.1.1.2).
NOTE 2 Boards may also have a profiled edge. 3.1.2.2 level given value which is the upper or lower limit of a requirement. The level is given by the declared value of the characteristic concerned 3.1.2.3 class combination of two levels of the same property between which the performance shall fall 3.2 Symbols units and abbreviated terms 3.2.1 Symbols and units used in this standard: a is the coefficient describing the influence of moisture on the thermal conductivity – b is the width mm c is the compressibility mm d is the thickness mm



prEN 13169:2008 (E) 8 dB is the thickness under a load of 2 kPa after removal of an additional load of 48 kPa mm dL is the thickness under a load of 250 kPa mm dN is the nominal thickness of the product mm ∆εb is the relative change in width % ∆εd is the relative change in thickness % ∆εl is the relative change in length % k is a factor related to the number of test results available – l is the length mm λD is the declared thermal conductivity W/(m⋅K) λi is one test result of thermal conductivity W/(m⋅K) λmean is the mean thermal conductivity W/(m⋅K) λ10,dry is the thermal conductivity in the dry state W/(m⋅K) λ90/90 is the 90 % fractile with a confidence level of 90 % for the thermal conductivity W/(m⋅K) m1 is the mass of the test specimen after 2 h total immersion in water kg m23,dry is the mass of specimen in the dry state kg m23,50 is the mass of specimen at 23 °C and 50 % relative humidity kg µ is the water vapour diffusion resistance factor – n is the number of test results – RD is the declared thermal resistance m2⋅K/W Ri is one test result of thermal resistance m2⋅K/W Rmean is the mean thermal resistance m2⋅K/W R90/90 is the 90 % fractile with a confidence level of 90 % for the thermal resistance m2⋅K/W Sb is the deviation from squareness on length and width mm/m Smax is the deviation from flatness mm sR is the estimate of the standard deviation of the thermal resistance m2⋅K/W sλ is the estimate of the standard deviation of the thermal conductivity W/(m⋅K) s′ is the dynamic stiffness MN/m3 σb is the bending strength kPa σbc is the bending strength at a constant span kPa σc is the declared compressive stress kPa σm is the compressive strength kPa σmt is the tensile strength perpendicular to faces kPa σ10 is the compressive stress at 10 % deformation kPa u23,50 is the moisture content by mass at 23 °C and 50 % relative humidity kg/kg



prEN 13169:2008 (E) 9 V is the volume of the specimen m3 Wp is the short-term water absorption by partial immersion kg/m2 Wst is the short-term water absorption by total immersion kg/dm3 X0 is the initial deformation after 60 s from the beginning of loading mm Xct is the compressive creep mm Xt is the deformation at time t (total thickness reduction) mm Z is the water vapour resistance m2⋅h⋅Pa/mg BS is the symbol of the declared level of bending strength BS(z) is the symbol of the declared level of bending strength at a constant span CC(i1/i2/y)σc is the symbol of the declared level for compressive creep CP is the symbol of the declared level for compressibility CS(10\Y) is the symbol of the declared level for compressive stress or compressive strength DLT(i)5 is the symbol of the declared level of deformation under load and temperature DS(H) is the symbol of the declared value for dimensional stability under humidity condition DS(T+/50) is the symbol of the declared value for dimensional stability under specified temperatureand humidity MU is the symbol of the declared value for water vapour diffusion resistance factor PL(2) is the symbol of the declared level of point load for 2 mm deformation SD is the symbol of the declared level of dynamic stiffness T is the symbol of the declared class for thickness tolerances TR is the symbol of the declared value for tensile strength perpendicular to faces WS is the symbol of the declared level for short term water absorption absorption by partialimmersion WS(T) is the symbol of the declared level of short term water absorption by total immersion Z is the symbol of the declared value for water vapour resistance 3.2.2 Abbreviated terms used in this standard: EPB is Expanded Perlite Board ITT
is Initial Type Test 4 Requirements 4.1 General Product properties shall be assessed in accordance with clause 5. To comply with this standard, products shall meet the requirements of 4.2, and the requirements of 4.3 as appropriate. NOTE Information on additional properties is given in Annex E. One test result on a product property is the average of the measured values on the number of test specimens given in Table 6.



prEN 13169:2008 (E) 10 4.2 For all applications 4.2.1 Thermal resistance and thermal conductivity Thermal resistance and thermal conductivity shall be based upon measurements carried out in accordance with EN 12667 or EN 12939 for thick products. The thermal resistance and thermal conductivity shall be determined in accordance with Annex A and Annex C, and declared by the manufacturer according to the following:  the reference mean temperature shall be 10 °C;  the measured values shall be expressed with three significant figures;  for products of uniform thickness, the thermal resistance, RD, shall always be declared. The thermal conductivity, λD, shall be declared where possible. Where appropriate, for products of non-uniform thickness (i.e. for sloped and tapered products) only the thermal conductivity, λD, shall be declared.  the declared thermal resistance, RD, and thermal conductivity, λD, shall be given as limit values representing at least 90 % of the production, determined with a confidence level of 90 %;  the value of thermal conductivity, λ90/90, shall be rounded upwards to the nearest 0,001 W/(m⋅K) and declared as λD in levels with steps of 0,001 W/(m⋅K);  the declared thermal resistance, RD, shall be calculated from the nominal thickness, dN, and the corresponding thermal conductivity, λ90/90;  the value of thermal resistance, R90/90, when calculated from the nominal thickness, dN, and the corresponding thermal conductivity, λ90/90, shall be rounded downwards to the nearest 0,05 m2⋅K/W, and declared as RD in levels with steps of 0,05 m2⋅K/W;  the value of R90/90, for those products for which only thermal resistance is measured directly, shall be rounded downwards to the nearest 0,05 m2 K/W, and declared as RD in levels with steps of 0,05 m2⋅K/W. 4.2.2 Length and width Length, l, and width, b, shall be determined in accordance with EN 822. No test result shall deviate from the nominal values by more than the following: ± 3 mm for length and width not exceeding 1 200 mm; ± 5 mm for length and width exceeding 1 200 mm. In the case of bonded boards, the offset on the edges shall not exceed 3 mm.



prEN 13169:2008 (E) 11 4.2.3 Thickness Thickness, d, shall be determined in accordance with EN 823, using a load equal to 250 Pa. No test result shall deviate from the nominal thickness, dN, by more than the corresponding tolerances given in Table 1. Table 1 — Thickness tolerances Dimensions in millimetres Nominal thickness dN ≤ 35 35 < dN ≤ 70 70 < dN ≤ 120 dN > 120 Tolerance ± 1 ± 2 ± 3 ± 4
This test shall not be performed when the tests described in D.2.7 are used. 4.2.4 Squareness Squareness shall be determined in accordance with EN 824. The deviation from squareness on length and width, Sb, shall not exceed 3 mm/m. 4.2.5 Flatness Flatness shall be determined in accordance with EN 825. The deviation from flatness, Smax, shall not exceed the following: 3 mm for length and width not exceeding 1 200 mm; 5 mm for length and width exceeding 1 200 mm. 4.2.6 Bending strength Bending strength, σb, shall be determined in accordance with EN 12089. For handling purpose, the bending strength of boards shall not be less than 250 kPa. NOTE The requirement for handling applies to individual boards. In the case of multi-layered boards, it may be assumed that the requirement is satisfied when each of the individual layers fulfills this requirement. 4.2.7 Dimensional stability under specified temperature and humidity conditions Dimensional stability under specified humidity conditions shall be determined in accordance with EN 1604. The test shall be carried out for 48 h at (23 ± 2) °C and (90 ± 5) % relative humidity. The relative changes in length, ∆εl, and width, ∆εb, shall not exceed 0,5 %. The relative changes in thickness, ∆εd, shall not exceed 1 %. 4.2.8 Reaction to fire Reaction to fire classification (Euroclasses) shall be determined in accordance with EN 13501-1. 4.2.9 Durability characteristics 4.2.9.1 General The appropriate durability characteristics have been considered and are covered in 4.2.9.2, 4.2.9.3 and 4.2.9.4.



prEN 13169:2008 (E) 12 4.2.9.2 Durability of reaction to fire against ageing/ degradation The reaction to fire performance of factory made products of expanded perlite does not change with time. 4.2.9.3 Durability of thermal resistance against ageing/ degradation The thermal conductivity of factory made products of expanded perlite does not change with time. This is covered by 4.2.1 thermal conductivity, 4.2.2 Length and width and 4.2.7 dimensional stability or 4.3.2 dimensional stability. 4.2.9.4 Durability of compressive strength against ageing/degradation The durability of compressive strength is covered by 4.3.9 compressive creep. 4.3 For specific applications 4.3.1 General If there is no requirement for a property described in 4.3 for a product in use, then the property does not need to be determined and declared by the manufacturer. 4.3.2 Dimensional stability under specified temperature and humidity conditions Dimensional stability under specified temperature conditions shall be determined in accordance with EN 1604. The test shall be carried out for 48 h exposure at (70 ± 2) °C and (50 ± 5) % relative humidity. The relative changes in length, ∆εl, and width, ∆εb, shall not exceed 0,5 %. The relative changes in thickness, ∆εd, shall not exceed 1 %. 4.3.3 Compressive stress or compressive strength Compressive stress at 10 % deformation, σ10, or the compressive strength, σm, shall be determined in accordance with EN 826. No test result for either the compressive stress at 10 % deformation, σ10, or the compressive strength, σm, whichever is the smaller, shall be less than the value given in Table 2, for the declared level. Table 2 — Levels for compressive stress or compressive strength Level Requirement kPa CS(10\Y)100 ≥ 100 CS(10\Y)125 ≥ 125 CS(10\Y)150 ≥ 150 CS(10\Y)200 ≥ 200 CS(10\Y)300 ≥ 300 CS(10\Y)450 ≥ 450 CS(10\Y)700 ≥ 700 CS(10\Y)800 ≥ 800



prEN 13169:2008 (E) 13 4.3.4 Deformation under specified load and temperature Deformation in thickness under specified load and temperature conditions shall be determined in accordance with EN 1605. The relative deformation in thickness, ∆εd, shall not exceed the values given in Table 3 for the declared level. Table 3 — Levels for deformation under specified compressive load and temperature Level Requirement % Test conditions DLT(1)5 ≤ 5 Load: 20 kPa Temperature: (80 ± 1) °C Time: (48 ± 1) h DLT(2)5 ≤ 5 Load: 40 kPa Temperature: (70 ± 1) °C Time: (168 ± 1) h DLT(3)5 ≤ 5 Load: 80 kPa Temperature: (60 ± 1) °C Time: (168 ± 1) h
4.3.5 Tensile strength perpendicular to faces Tensile strength perpendicular to faces, σmt, shall be determined in accordance with EN 1607, using the additional provisions of 5.3.3. No test result shall be lower than 20 kPa. 4.3.6 Water absorption 4.3.6.1 Short-term water absorption by partial immersion Short-term water absorption by partial immersion, Wp, shall be determined in accordance with EN 1609. No test result shall exceed the declared value. 4.3.6.2 Short-term water absorption by total immersion Short-term water absorption by total immersion, Wst, shall be determined in accordance with 5.3.4. No test result shall exceed the value, given in Table 4, for the declared level. Table 4 — Levels for water absorption by total immersion Level Requirement kg/dm3 WS(T) 8 ≤ 0,08 WS(T) 6 ≤ 0,06 WS(T) 4 ≤ 0,04 WS(T) 2 ≤ 0,02



prEN 13169:2008 (E) 14 4.3.7 Bending strength at a constant span Bending strength at a constant span of 250 mm, σbc, shall be determined in accordance with EN 12089. No test result shall be lower than the value given in Table 5, for the declared level. Table 5 — Levels for bending strength at constant span Level Requirement kPa BS(250)700 ≥ 700 BS(250)900 ≥ 900 BS(250)1100 ≥ 1 100 BS(250)1300 ≥ 1 300
4.3.8 Point load Point load at 2 mm deformation shall be determined in accordance with EN 12430 and declared in levels with steps of 50 N. No test result shall be less than the declared level. 4.3.9 Compressive creep Compressive creep, Xct, and total thickness reduction, Xt, shall be determined after at least one hundred twenty two days of testing at a declared compressive stress, σc, given in steps of at least 1 kPa, and the result extrapolated thirty times corresponding to ten years to obtain the declared levels in accordance with EN 1606. Compressive creep shall be declared in levels, i2, and the total thickness reduction shall be declared in levels, i1, with steps of 0,1 mm at the declared stress. No test result shall exceed the declared levels at the declared stress. NOTE Referring to the designation code CC(i1/i2/y)σc, according to clause 6, a declared level CC(2,5/2/10)100, as for example, indicates a value not exceeding 2 mm for compressive creep and 2,5 mm for total thickness reduction after ex
...