Double skin metal faced insulating panels - Factory made products - Specifications - Part 2: Structural applications - Fixings and potential uses of stabilization of individual structural elements

This European Standard specifies requirements for factory made, structural, double skin metal faced insulating sandwich panels, which are intended for discontinuous laying in the following applications:
a)   roofs and roof cladding (e.g. for refurbishment);
b)   external walls and wall cladding (e.g. on brick walls for refurbishment or sandwich panels on liner trays);
c)   walls (including partitions) and ceilings within the building envelope.
It is essential that structural double skin metal faced insulating sandwich panels according to this European Standard (EN 14509-2) fulfil the requirements of EN 14509.
This European Standard (EN 14509-2) gives the basic rule for use of structural sandwich panels for structural applications including fixing of panels. The clarification of which application is structural needs to be given by national provisions. The stabilization parameters needed to contribute to stabilization of individual structural elements (supporting structure) as defined as structural class II according to EN 1993-1-3 are included.
The insulating core materials covered by this European Standard are rigid polyurethane, expanded polystyrene, extruded polystyrene foam, phenolic foam, cellular glass and mineral wool.
NOTE   Polyurethane (PUR) includes polyisocyanurate (PIR).
Due to durability performance reason coated face material of steel is used only (both organic and metallic coating). Uncoated steel is not used as face material.
Panels with edge details that utilise different materials from the main insulating core are included in this European Standard if there is no influence on mechanical performance of the panel.
Panels used in cold store applications are included in this European Standard. Panels, put on the market as a component of a cold storage room, building and/or building envelope kit are covered by ETA-Guideline 021 “Cold storage premises kits”.
When manufactured in accordance with this European Standard and if satisfying the type testing and FPC criteria the panels can be considered as impermeable to water. The water permeability of the assembly is a function of its installation and is only relevant to the joints and fixings.
This European Standard does not cover the following:
d)   sandwich panels with a declared thermal conductivity for the insulating core greater than defined in the relevant harmonized European Standards for insulation materials;
e)   products consisting of two or more clearly defined layers of different insulating core materials (multi-layered);
f)   curved panels;
g)   perforated panels;
h)   hidden fixings under permanent tension load, e.g. for ceilings;
i)   special type of fasteners such as ‘T’ support for ceiling, threaded rods with clamps for wall, omega and clamps for wall and ceiling, injected joint with flashing and threaded rods for wall and ceiling.

Sandwich-Elemente mit beidseitigen Metalldeckschichten - Werkmäßig hergestellte Produkte - Spezifikationen - Teil 2: Tragende Anwendungen - Befestigungen und mögliche Nutzung zur Stabilisierung von einzelnen tragenden Bauteilen

Diese Europäische Norm legt Anforderungen an werkmäßig hergestellte selbsttragende Sandwichelemente mit beidseitigen Metalldeckschichten fest, die für elementweise Verlegung mit übergreifenden oder überlappenden Längsfugen in den folgenden Anwendungen bestimmt sind:
a)   Dächer und Dachdeckungen (z. B. für Renovierungen);
b)   Außenwände und Wandverkleidungen (z. B. auf Ziegelmauern für Renovierungen oder Sandwichelemente auf Kassettenprofilen);
c)   Wände (einschließlich Trennwänden) und (Unter )Decken innerhalb der Gebäudehülle.
Es ist entscheidend, dass selbsttragende Sandwichelemente mit beidseitigen Metalldeckschichten nach dieser Europäischen Norm (EN 14509 2) die Anforderungen von EN 14509 erfüllen.
Diese Europäische Norm (EN 14509 2) legt Grundregeln für die Verwendung von selbsttragenden Sandwichelementen für bauliche Anwendungen fest, einschließlich der Befestigung der Elemente. Die Erläuterung, welche Anwendungen baulicher Art sind, hat durch nationale Bestimmungen zu erfolgen. Die zur Stabilisierung einzelner tragende Bauteile beitragenden Stabilisierungsparameter (Auflagerkonstruktion) nach der Einteilung in Konstruktionsklasse II nach EN 1993 1 3 sind eingeschlossen.
Die von dieser Europäischen Norm abgedeckten Dämmkernwerkstoffe sind Polyurethan-Hartschaum, expandiertes Polystyrol, extrudierter Polystyrolschaum, Phenolharzschaum, Schaumglas und Mineralwolle.
ANMERKUNG   Polyurethan (PUR) schließt Polyisocyanurat (PIR) ein.
Aus Gründen der Dauerhaftigkeit werden ausschließlich beschichtete Deckschichten aus Stahlwerkstoffen eingesetzt (organische und metallische Beschichtungen). Unbeschichteter Stahl wird nicht als Werkstoff für Deckschichten verwendet.
Dämmelemente (im Folgenden "Elemente" genannt) mit Kantenausführungen, für die andere Werkstoffe als für den Hauptdämmkern verwendet werden, sind Gegenstand dieser Europäischen Norm, sofern die mechanischen Eigenschaften des Elements dadurch nicht beeinträchtigt werden.
Dämmelemente für Kühlhausanwendungen sind Gegenstand dieser Europäischen Norm. Elemente, die als Bauteil für ein Kühlhaus, für Gebäude und/oder als Bausatz für die Gebäudehülle in Verkehr gebracht werden, sind durch die ETA-Richtlinie 021 „Bausätze für Kühlhäuser“ abgedeckt.
Elemente, die in Übereinstimmung mit dieser Europäischen Norm gefertigt und die Typprüfung und werkseigene Produktionskontrolle bestanden haben, können als wasserundurchlässig betrachtet werden. Die Wasserdurchlässigkeit des Zusammenbaus ist eine Funktion des Einbaus und bezieht sich nur auf Fugen und Befestigungen.
Diese Europäische Norm gilt nicht für:
a)   Sandwichelemente mit einer Nenn-Wärmeleitfähigkeit des Dämmkerns, welche die in den relevanten harmonisierten Europäischen Normen für Dämmwerkstoffe festgelegten Werte übersteigt;
b)   Produkte, die aus zwei oder mehr eindeutig festgelegten Schichten unterschiedlicher Dämmkernwerkstoffe bestehen (Mehrschicht-Produkte);
c)   gekrümmte Elemente;
d)   perforierte Elemente;
e)   verborgene Befestigungen unter permanenter Spannungslast, z. B. für (Unter-) Decken;
f)   spezielle Befestigungselemente wie T-Träger für (Unter-) Decken, Gewindestangen mit Klemmen für Wand, Omegabügel und Klemmen für Wand und (Unter-) Decke, eingepresste Verbindungen mit Dachverwahrung und Gewindestangen für Wand und (Unter-) Decke.

Panneaux sandwiches, isolants, double peau métalliques - Produits manufacturés - Spécifications - Partie 2: Applications structurelles - Assemblages et utilisation potentielles pour stabilisation d’éléments structurels individuels

La présente Norme européenne spécifie les exigences applicables aux panneaux sandwiches manufacturés, structurels, isolants, double peau métalliques, utilisés pour la pose en discontinu dans les cas suivants :
a)   couvertures et surtoitures (par exemple, pour la réhabilitation) ;
b)   bardages et contre-bardages (par exemple, sur des parois en brique pour réhabilitation ou des panneaux sandwiches sur des plateaux) ;
c)   parois (y compris cloisons) et plafonds dans l'enveloppe du bâtiment.
Les panneaux sandwiches structurels, isolants, double peau métalliques selon la présente Norme européenne (EN 14509-2) doivent satisfaire aux exigences de l'EN 14509.
La présente Norme européenne (EN 14509-2) énonce la règle de base pour l'utilisation de panneaux sandwiches structurels pour des applications structurelles comprenant l'assemblage des panneaux. Des dispositions nationales doivent indiquer clairement les applications qui doivent être considérées comme structurelles. Cela inclut les paramètres de stabilisation nécessaires pour contribuer à la stabilisation des éléments structurels individuels (structure d’appui) définis comme appartenant à la classe structurelle II selon l'EN 1993-1-3.
Les matériaux d'âme isolante couverts par la présente Norme européenne sont : le polyuréthane rigide, le polystyrène expansé, la mousse de polystyrène extrudé, la mousse phénolique, le verre cellulaire et la laine minérale.
NOTE   Le polyuréthane (PUR) comprend le polyisocyanurate (PIR).
Pour des raisons de performances de durabilité, seul l'acier revêtu est utilisé comme matériau de parement (revêtement à la fois organique et métallique). L'acier non revêtu n'est pas utilisé en tant que matériau de parement.
La présente Norme européenne inclut les panneaux dont les chants sont en matériaux autres que le matériau d'âme isolant principal, si cela n'a aucune influence sur les performances mécaniques des panneaux.
Elle inclut également les panneaux utilisés dans des applications pour chambres froides. Les panneaux, mis sur le marché en tant que composant de chambre d'entreposage frigorifique, de bâtiment et/ou d'équipements d'enveloppe de bâtiment, font l'objet du guide 021 de l'ETA « Équipements de locaux d'entreposage frigorifique ».
Lorsqu'ils sont fabriqués conformément à la présente Norme européenne et qu'ils satisfont aux essais de type et aux critères du CPU, les panneaux peuvent être réputés imperméables à l'eau. La perméabilité à l'eau de l'ensemble est fonction de son installation et concerne uniquement les assemblages et fixations.
La présente Norme européenne ne couvre pas ce qui suit :
d)   les panneaux sandwiches dont la conductivité thermique déclarée de l'âme isolante est supérieure à celle définie dans les normes européennes harmonisées pertinentes pour les matériaux isolants ;
e)   les produits comportant au moins deux couches clairement définies de différents matériaux d’âme isolante (multicouches) ;
f)   les panneaux cintrés ;
g)   les panneaux perforés ;
h)   les fixations cachées sous une charge de traction permanente, par exemple pour les plafonds ;
i)   des types spéciaux d’éléments de fixation tels que des appuis en T pour plafond, des tiges filetées avec brides pour paroi, profils oméga et brides pour mur et plafond, joint injecté avec couvre-joint et tiges filetées pour paroi et plafond.

Izolacijske sendvič plošče z obojestranskim kovinskim oplaščenjem - Tovarniško izdelani proizvodi - Specifikacije - 2. del: Konstrukcijska uporaba - Pritrditev in možna uporaba za stabilizacijo posameznih konstrukcijskih elementov

General Information

Status
Not Published
Public Enquiry End Date
04-Dec-2017
Technical Committee
Current Stage
4020 - Public enquire (PE) (Adopted Project)
Start Date
19-Oct-2017
Due Date
08-Mar-2018
Completion Date
09-Jan-2018

Relations

Buy Standard

Draft
prEN 14509-2:2017 - BARVE
English language
70 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
oSIST prEN 14509-2:2017
01-december-2017
,]RODFLMVNHVHQGYLþSORãþH]RERMHVWUDQVNLPNRYLQVNLPRSODãþHQMHP7RYDUQLãNR
L]GHODQLSURL]YRGL6SHFLILNDFLMHGHO.RQVWUXNFLMVNDXSRUDED3ULWUGLWHYLQ
PRåQDXSRUDED]DVWDELOL]DFLMRSRVDPH]QLKNRQVWUXNFLMVNLKHOHPHQWRY
Double skin metal faced insulating panels - Factory made products - Specifications - Part
2: Structural applications - Fixings and potential uses of stabilization of individual
structural elements
Sandwich-Elemente mit beidseitigen Metalldeckschichten - Werkmäßig hergestellte
Produkte - Spezifikationen - Teil 2: Tragende Anwendungen - Befestigungen und
mögliche Nutzung zur Stabilisierung von einzelnen tragenden Bauteilen
Panneaux sandwiches, isolants, double peau métalliques - Produits manufacturés -
Spécifications - Partie 2: Applications structurelles - Assemblages et utilisation
potentielles pour stabilisation d’éléments structurels individuels
Ta slovenski standard je istoveten z: prEN 14509-2
ICS:
91.100.60 0DWHULDOL]DWRSORWQRLQ Thermal and sound insulating
]YRþQRL]RODFLMR materials
oSIST prEN 14509-2:2017 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
oSIST prEN 14509-2:2017

---------------------- Page: 2 ----------------------
oSIST prEN 14509-2:2017


DRAFT
EUROPEAN STANDARD
prEN 14509-2
NORME EUROPÉENNE

EUROPÄISCHE NORM

September 2017
ICS 91.100.60
English Version

Double skin metal faced insulating panels - Factory made
products - Specifications - Part 2: Structural applications -
Fixings and potential uses of stabilization of individual
structural elements
Panneaux sandwiches, isolants, double peau Sandwich-Elemente mit beidseitigen
métalliques - Produits manufacturés - Spécifications - Metalldeckschichten - Werkmäßig hergestellte
Partie 2: Applications structurelles - Assemblages et Produkte - Spezifikationen - Teil 2: Tragende
utilisation potentielles pour stabilisation d'éléments Anwendungen - Befestigungen und mögliche Nutzung
structurels individuels zur Stabilisierung von einzelnen tragenden Bauteilen
This draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee
CEN/TC 128.

If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations
which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.

This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and United Kingdom.

Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.

Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without
notice and shall not be referred to as a European Standard.


EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2017 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 14509-2:2017 E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------
oSIST prEN 14509-2:2017
prEN 14509-2:2017 (E)
Contents Page
European foreword . 5
1 Scope . 6
2 Normative references . 7
3 Terms and definitions . 9
4 Symbols and abbreviations . 10
4.1 General. 10
4.2 Symbols . 10
4.3 Subscripts . 10
4.4 Abbreviations . 10
5 Product characteristics, properties and test methods . 10
5.1 General. 10
5.2 Characteristics of metal facings . 10
5.2.1 Steel. 10
5.2.2 Aluminium . 11
5.2.3 Copper . 11
5.3 Characteristics of core materials . 11
5.3.1 Thermal performance . 11
5.3.2 Thermal stability of core materials . 11
5.3.3 Adhesives and bonding . 11
5.4 Characteristics of fastenings . 11
5.4.1 Charachteristics of fasteners . 11
5.4.2 Characteristics of load spreading plates . 11
5.4.3 Characteristics of sealing washers . 11
5.5 Characteristics of panels . 11
5.5.1 Mechanical resistance of the panel . 11
5.5.2 Durability - Corrosion protection of sandwich panel metal faces . 12
5.5.3 Tensile resistance and shear resistance to fixings . 12
5.5.4 Material safety factors (γ ) . 12
M
5.5.5 Stabilization effect of the supporting structure . 13
5.5.6 Thermal transmittance . 13
5.5.7 Durability and other long-term effects . 13
5.5.8 Fire characteristics . 13
5.5.9 Dimensional tolerances for sandwich panels . 13
5.5.10 Water permeability . 13
5.5.11 Air permeability . 13
5.5.12 Water vapour permeability. 13
5.5.13 Airborne sound insulation (R (C;C )) . 13
w tr
5.5.14 Sound absorption (α ) . 13
w
5.5.15 Dangerous substances. 13
5.5.16 Actions and safety level requirements . 14
6 Assessment and verification of constancy of performance - AVCP . 14
6.1 General. 14
6.2 Type testing . 14
6.2.1 General. 14
6.2.2 Type evaluation . 14
6.2.3 Existing type testing data . 15
2

---------------------- Page: 4 ----------------------
oSIST prEN 14509-2:2017
prEN 14509-2:2017 (E)
6.2.4 Test samples, testing and compliance criteria . 15
6.2.5 Testing and compliance criteria – Type Testing . 16
6.2.6 Shortened testing programme – Type Testing (product change) . 16
6.2.7 Test reports . 17
6.3 Factory production control (FPC) . 17
6.3.1 General . 17
6.3.2 Results of FPC tests . 17
6.3.3 Equipment . 17
6.3.4 Raw materials and components . 17
6.3.5 Product testing and assessment – FPC . 18
6.3.6 Traceability and marking . 18
6.3.7 Handling, storage and packaging . 18
6.3.8 Initial inspection of factory and of FPC . 18
6.3.9 Continuous surveillance of FPC . 18
6.3.10 Procedure for modifications . 19
7 Classification and designation . 19
8 Marking, labelling and packaging . 20
8.1 Marking and labelling . 20
8.2 Packaging, transport, storage and handling . 20
Annex A (normative) Testing procedures for material properties . 21
Annex B (normative) Corrosion protection by metallic coatings with or without organic
coatings on steel sheet . 22
B.1 Corrosion protection . 22
B.2 Suitability of corrosion protection . 24
B.2.1 Selection . 24
B.2.2 Examination of suitability (initial inspection) . 28
B.2.3 Monitoring . 30
B.2.4 Galvanic corrosion . 31
Annex C (normative) Fire performance tests – additional instructions and direct field of
application . 34
Annex D (normative) Dimensional tolerances . 35
Annex E (normative) Design procedures . 36
E.1 General . 36
E.2 Design of fixing. 36
Annex F (normative) Testing of the resistance of fixings of sandwich panels to supporting
structures . 37
F.1 General . 37
F.1.1 Type of fixings and panel families . 37
F.1.2 Test reports . 38
F.2 Tensile resistance . 39
F.2.1 General . 39
F.2.2 Visible fixing . 40
F.2.3 Hidden fixing . 44
3

---------------------- Page: 5 ----------------------
oSIST prEN 14509-2:2017
prEN 14509-2:2017 (E)
F.3 Shear resistance . 47
F.3.1 Visible fixing . 47
F.3.2 Hidden fixing . 49
F.4 Full scale tests, alternative test method for tensile strength of hidden fixing . 49
F.4.1 General. 49
F.4.2 Principle . 50
F.4.3 Apparatus – test equipment . 50
F.4.4 Test specimen . 51
F.4.5 Test procedure and number of tests . 53
F.4.6 Statistical analysis of the results and characteristic values. . 54
F.4.7 Calculations and results . 54
Annex G (normative) Parameters needed for determining stiffening effect of sandwich
panels when connected to supporting structures . 55
G.1 Principle . 55
G.2 Rotational spring stiffness . 55
G.2.1 Rotational stiffness C . 55
D
G.2.2 Determination of rotational spring stiffness C by testing . 55
D,A
G.2.3 Determination of rotational spring stiffness C by calculation . 60
D,A
G.2.4 Rotational stiffness C . 62
D
G.3 Shear stiffness S for lateral restraint of an individual member . 63
Annex ZA (informative) Relationship of this European Standard with Regulation (EU)
No.305/2011 . 65
ZA.1 Scope and relevant characteristics . 65
ZA.2 System of Assessment and Verification of Constancy of Performance (AVCP) . 66
ZA.3 Assignment of AVCP tasks . 67
Bibliography . 70

4

---------------------- Page: 6 ----------------------
oSIST prEN 14509-2:2017
prEN 14509-2:2017 (E)
European foreword
This document (prEN 14509-2:2017) has been prepared by Technical Committee CEN/TC 128 “Roof
covering products for discontinuous laying and products for wall cladding”, the secretariat of which is
held by NBN.
This document is currently submitted to the CEN Enquiry.
This document has been prepared under a standardisation request given to CEN by the European
Commission and the European Free Trade Association, and supports basic works requirements of EU
Regulation.
For relationship with EU Regulation, see informative Annex ZA, which is an integral part of this
document.
Data obtained from earlier tests in accordance to EN 14509:2006 and 2013 may be used for obtaining
the declared data providing that they do not change significantly.
This European Standard (EN 14509-2) gives the basic rules for use of structural sandwich panels for
structural applications including fixing of panels. The clarification of which application is structural
needs to be given by national provisions. The stabilization parameters needed to contribute to
stabilization of individual structural elements (supporting structure) as defined as structural class II
according to EN 1993-1-3. Sandwich panels fulfilling requirements for applications for structural class
II are seemed to fulfill also applications for structural class III according to EN 1993-1-3.
In EN 14509 (covering panels used as self-supporting) the rules for declaring the basic panel properties
that are common for all applications (use as self-supporting and/or structural) are given.
NOTE 1 In future EN 14509 will become EN 14509-1.
NOTE 2 In future EN 14509-3 will specify sandwich panels used for contribution to overall strength and
stabilization of buildings (structural class I according to EN 1993-1-3) and as axially loaded panels.
5

---------------------- Page: 7 ----------------------
oSIST prEN 14509-2:2017
prEN 14509-2:2017 (E)
1 Scope
This European Standard specifies requirements for factory made, structural, double skin metal faced
insulating sandwich panels, which are intended for discontinuous laying in the following applications:
a) roofs and roof cladding (e.g. for refurbishment);
b) external walls and wall cladding (e.g. on brick walls for refurbishment or sandwich panels on liner
trays);
c) walls (including partitions) and ceilings within the building envelope.
It is essential that structural double skin metal faced insulating sandwich panels according to this
European Standard (EN 14509-2) fulfil the requirements of EN 14509.
This European Standard (EN 14509-2) gives the basic rule for use of structural sandwich panels for
structural applications including fixing of panels. The clarification of which application is structural
needs to be given by national provisions. The stabilization parameters needed to contribute to
stabilization of individual structural elements (supporting structure) as defined as structural class II
according to EN 1993-1-3 are included.
The insulating core materials covered by this European Standard are rigid polyurethane, expanded
polystyrene, extruded polystyrene foam, phenolic foam, cellular glass and mineral wool.
NOTE Polyurethane (PUR) includes polyisocyanurate (PIR).
Due to durability performance reason coated face material of steel is used only (both organic and
metallic coating). Uncoated steel is not used as face material.
Panels with edge details that utilise different materials from the main insulating core are included in
this European Standard if there is no influence on mechanical performance of the panel.
Panels used in cold store applications are included in this European Standard. Panels, put on the market
as a component of a cold storage room, building and/or building envelope kit are covered by ETA-
Guideline 021 “Cold storage premises kits”.
When manufactured in accordance with this European Standard and if satisfying the type testing and
FPC criteria the panels can be considered as impermeable to water. The water permeability of the
assembly is a function of its installation and is only relevant to the joints and fixings.
This European Standard does not cover the following:
d) sandwich panels with a declared thermal conductivity for the insulating core greater than defined
in the relevant harmonized European Standards for insulation materials;
e) products consisting of two or more clearly defined layers of different insulating core materials
(multi-layered);
f) curved panels;
g) perforated panels;
h) hidden fixings under permanent tension load, e.g. for ceilings;
i) special type of fasteners such as ‘T’ support for ceiling, threaded rods with clamps for wall, omega
and clamps for wall and ceiling, injected joint with flashing and threaded rods for wall and ceiling.
6

---------------------- Page: 8 ----------------------
oSIST prEN 14509-2:2017
prEN 14509-2:2017 (E)
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
EN 508-1:2014, Roofing and cladding products from metal sheet — Specification for self-supporting of
steel, aluminium or stainless steel sheet — Part 1: Steel
EN 1090-2:2008+A1:2011, Execution of steel structures and aluminium structures — Part 2: Technical
requirements for steel structures
prEN 1090-4:2015, Execution of steel structures and aluminium structures —Part 4: Technical
requirements for cold-formed structural steel elements and cold-formed structures for roof, ceiling, floor
and wall applications
EN 1990:2002, Eurocode — Basis of structural design
EN 1993-1-3:2006, Eurocode 3 — Design of steel structures — Part 1-3: General rules — Supplementary
rules for cold-formed members and sheeting
EN 1993-1-4:2006, Eurocode 3 — Design of steel structures — Part 1-4: General rules — Supplementary
rules for stainless steels
EN 10152:2017, Electrolytically zinc coated cold rolled steel flat products for cold forming — Technical
delivery conditions
EN 10169:2010+A1:2012, Continuously organic coated (coil coated) steel flat products — Technical
delivery conditions
EN 10204:2004, Metallic products — Types of inspection documents
EN 10346:2015, Continuously hot-dip coated steel flat products for cold forming — Technical delivery
conditions
EN 13523-1:2017, Coil coated metals — Test methods — Part 1: Film thickness
EN 13523-6:2002, Coil coated metals — Test methods — Part 6: Adhesion after indentation (cupping test)
EN 13523-7:2014, Coil coated metals — Test methods — Part 7: Resistance to cracking on bending (T-
bend test)
EN 13523-8:2017, Coil coated metals — Test methods — Part 8: Resistance to salt spray (fog)
EN 13523-10:2017, Coil coated metals — Test methods - Part 10: Resistance to fluorescent UV radiation
and water condensation
EN 13523-19:2011, Coil coated metals — Test methods — Part 19: Panel design and method of
atmospheric exposure testing
EN 13523-21:2017, Coil coated metals — Test methods — Part 21: Evaluation of outdoor exposed panels
EN 13523-26:2014, Coil coated metals — Test methods — Part 26: Resistance to condensation of water
7

---------------------- Page: 9 ----------------------
oSIST prEN 14509-2:2017
prEN 14509-2:2017 (E)
1
EN 14509:2013 , Self-supporting double skin metal faced insulating panels — Factory made products —
Specifications
EN ISO 1461:2009, Hot dip galvanized coatings on fabricated iron and steel articles — Specifications and
test methods (ISO 1461:2009)
EN ISO 2081:2008, Metallic and other inorganic coatings — Electroplated coatings of zinc with
supplementary treatment
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.