SIST EN 61169-51:2015
(Main)Radio-frequency connectors - Part 51: Sectional specifications RF coaxial connectors with inner diameter of outer conductors 13.5 mm with bayonet lock. Characteristics impedance 50 Ohm (type QLI) (IEC 61169-51:2015)
Radio-frequency connectors - Part 51: Sectional specifications RF coaxial connectors with inner diameter of outer conductors 13.5 mm with bayonet lock. Characteristics impedance 50 Ohm (type QLI) (IEC 61169-51:2015)
This part of IEC 61169, which is a sectional specification (SS), provides information and rules
for the preparation of detail specifications (DS) for type QLI R.F. coaxial connectors with quick
lock.
The connectors are normally used with 50 Ω corrugated cable and flexible cables for middle
power applications in an operating range up to 6 GHz.
It describes the interface dimensions for general purpose connectors with gauging information
and the mandatory tests selected from IEC 61169-1 applicable to all detail specifications
relative to type QLI connectors.
This specification indicates the recommended performance characteristics to be considered
when writing a DS and covers all tests schedules and inspection requirements.
NOTE Metric dimension are original dimensions.
All un-dimensioned pictorial configurations are for reference purpose only.
Hochfrequenz-Steckverbinder - Teil 51: Rahmenspezifikation für koaxiale HF Steckverbinder mit 13,5 mm Innendurchmesser des Außenleiters und Bajonettverschluss - Wellenwiderstand 50 Ohm (Typ QLI) (IEC 61169-51:2015)
Connecteurs pour fréquences radioélectriques - Partie 51: Spécification intermédiaire relative aux connecteurs coaxiaux pour fréquences radioélectriques avec diamètre intérieur des conducteurs extérieurs de 13,5 mm à verrouillage à baïonnette - Impédance caractéristique 50 O (type QLI) (IEC 61169-51:2015)
L'IEC 61169-51:2015 fournit des informations et des règles en vue de l'établissement de spécifications particulières (SP) relatives aux connecteurs coaxiaux pour fréquences radioélectriques de type QLI à verrouillage rapide. Les connecteurs sont normalement utilisés avec des câbles 50 Ohms annelés et des câbles souples pour des applications en moyenne puissance au sein d'une plage de fonctionnement inférieure ou égale à 6 GHz. Elle décrit les dimensions d'interface pour des connecteurs d'usage général, ainsi que des informations concernant les calibres et les essais obligatoires choisis dans l'IEC 61169-1, applicables à toutes les spécifications particulières ayant trait aux connecteurs de type QLI. La présente spécification indique les caractéristiques de performance recommandées à prendre en compte pour la rédaction d'une SP et elle couvre tous les programmes d'essais et les exigences de contrôle.
Radiofrekvenčni konektorji - 51. del: Področne specifikacije za radiofrekvenčne koaksialne konektorje z notranjim premerom zunanjih vodnikov 13,5 mm in bajonetnim zaklepom - Karakteristična impedanca 50 Ohm (tip QLI) (IEC 61169-51:2015)
Ta del standarda IEC 61169, ki je področna specifikacija (SS), podaja informacije in določa pravila za pripravo podrobnih specifikacij (DS) za radiofrekvenčne koaksialne konektorje vrste QLI z zaklepanjem. Konektorji se običajno uporabljajo s 50-ohmskim valovitim kablom in prožnimi kabli za srednjemočnostne uporabe v območju delovanja do 6 GHz. Opisuje dimenzije vmesnika za konektorje za splošni namen z informacijami o merjenju in obvezne preskuse, izbrane iz standarda IEC 61169-1, ki se uporabljajo za vse podrobne specifikacije v zvezi s konektorji tipa QLI.
Ta specifikacija določa priporočene lastnosti, ki jih je treba upoštevati pri sestavljanju podrobnih specifikacij, ter zajema vse urnike preskusov in zahteve za pregled.
OPOMBA: Izvirne mere so podane v metričnih merah. Vse nedimenzionirane slikovne konfiguracije so podane samo v referenčne namene.
General Information
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 61169-51:2015
01-oktober-2015
5DGLRIUHNYHQþQLNRQHNWRUMLGHO3RGURþQHVSHFLILNDFLMH]DUDGLRIUHNYHQþQH
NRDNVLDOQHNRQHNWRUMH]QRWUDQMLPSUHPHURP]XQDQMLKYRGQLNRYPPLQ
EDMRQHWQLP]DNOHSRP.DUDNWHULVWLþQDLPSHGDQFD2KPWLS4/,,(&
Radio-frequency connectors - Part 51: Sectional specifications RF coaxial connectors
with inner diameter of outer conductors 13.5 mm with bayonet lock. Characteristics
impedance 50 Ohm (type QLI) (IEC 61169-51:2015)
Hochfrequenz-Steckverbinder - Teil 51: Rahmenspezifikation für koaxiale HF
Steckverbinder mit 13,5 mm Innendurchmesser des Außenleiters und Bajonettverschluss
- Wellenwiderstand 50 Ohm (Typ QLI) (IEC 61169-51:2015)
Connecteurs pour fréquences radioélectriques - Partie 51: Spécification intermédiaire
relative aux connecteurs coaxiaux pour fréquences radioélectriques avec diamètre
intérieur des conducteurs extérieurs de 13,5 mm à verrouillage à baïonnette - Impédance
caractéristique 50 O (type QLI) (IEC 61169-51:2015)
Ta slovenski standard je istoveten z: EN 61169-51:2015
ICS:
33.120.30 5DGLRIUHNYHQþQLNRQHNWRUML R.F. connectors
5)
SIST EN 61169-51:2015 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST EN 61169-51:2015
---------------------- Page: 2 ----------------------
SIST EN 61169-51:2015
EUROPEAN STANDARD EN 61169-51
NORME EUROPÉENNE
EUROPÄISCHE NORM
May 2015
ICS 33.120.30
English Version
Radio-frequency connectors - Part 51: Sectional specification for
RF coaxial connectors with inner diameter of outer conductors
13,5 mm with bayonet lock - Characteristic impedance 50 O
(type QLI)
(IEC 61169-51:2015)
Connecteurs pour fréquences radioélectriques - Partie 51: Hochfrequenz-Steckverbinder - Teil 51:
Spécification intermédiaire relative aux connecteurs Rahmenspezifikation für koaxiale HF Steckverbinder mit
coaxiaux pour fréquences radioélectriques avec diamètre 13,5 mm Innendurchmesser des Außenleiters und
intérieur des conducteurs extérieurs de 13,5 mm à Bajonettverschluss - Wellenwiderstand 50 Ohm (Typ QLI)
verrouillage à baïonnette - Impédance caractéristique 50 O (IEC 61169-51:2015)
(type QLI)
(IEC 61169-51:2015)
This European Standard was approved by CENELEC on 2015-03-12. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2015 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 61169-51:2015 E
---------------------- Page: 3 ----------------------
SIST EN 61169-51:2015
EN 61169-51:2015 - 2 -
Foreword
The text of document 46F/295/FDIS, future edition 1 of IEC 61169-51, prepared by SC 46F "R.F. and
microwave passive components", of IEC/TC 46 "Cables, wires, waveguides, R.F. connectors, R.F. and
microwave passive components and accessories" was submitted to the IEC-CENELEC parallel vote
and approved by CENELEC as EN 61169-51:2015.
The following dates are fixed:
(dop) 2015-12-12
• latest date by which the document has to be implemented at
national level by publication of an identical national
standard or by endorsement
(dow) 2018-03-12
• latest date by which the national standards conflicting with
the document have to be withdrawn
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such
patent rights.
Endorsement notice
The text of the International Standard IEC 61169-51:2015 was approved by CENELEC as a European
Standard without any modification.
---------------------- Page: 4 ----------------------
SIST EN 61169-51:2015
- 3 - EN 61169-51:2015
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod), the relevant
EN/HD applies.
NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available here:
www.cenelec.eu.
Publication Year Title EN/HD Year
IEC 60529 - Degrees of protection provided by - -
enclosures (IP Code)
IEC 61169-1 2013 Radio-frequency connectors -- Part 1: EN 61169-1 2013
Generic specification - General
requirements and measuring methods
IEC 62037 series Passive RF and microwave devices, EN 62037 series
intermodulation level measurement
ISO 21207 - Corrosion tests in artificial atmospheres - - -
Accelerated corrosion tests involving
alternate exposure to corrosion-
promoting gases, neutral salt-spray and
drying
---------------------- Page: 5 ----------------------
SIST EN 61169-51:2015
---------------------- Page: 6 ----------------------
SIST EN 61169-51:2015
IEC 61169-51
®
Edition 1.0 2015-02
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
colour
inside
Radio-frequency connectors –
Part 51: Sectional specification for RF coaxial connectors with inner diameter of
outer conductors 13,5 mm with bayonet lock – Characteristic impedance 50 Ω
(type QLI)
Connecteurs pour fréquences radioélectriques –
Partie 51: Spécification intermédiaire relative aux connecteurs coaxiaux pour
fréquences radioélectriques avec diamètre intérieur des conducteurs extérieurs
de 13,5 mm à verrouillage à baïonnette – Impédance caractéristique 50 Ω
(type QLI)
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE
ICS 33.120.30 ISBN 978-2-8322-2238-6
Warning! Make sure that you obtained this publication from an authorized distributor.
Attention! Veuillez vous assurer que vous avez obtenu cette publication via un distributeur agréé.
® Registered trademark of the International Electrotechnical Commission
Marque déposée de la Commission Electrotechnique Internationale
---------------------- Page: 7 ----------------------
SIST EN 61169-51:2015
– 2 – IEC 61169-51:2015 © IEC 2015
CONTENTS
FOREWORD . 4
INTRODUCTION . 6
1 Scope . 7
2 Normative references. 7
3 Mating face and gauge information . 8
3.1 Dimensions – General connectors . 8
3.1.1 Connector with socket-centre contact . 8
3.1.2 Connector with pin-centre contact. 12
3.2 Gauges for connector with socket-centre contact . 14
3.2.1 Centre contact . 14
3.2.2 Test procedure . 14
3.2.3 Gauge for outer contact . 15
4 Quality assessment procedures . 15
4.1 General . 15
4.2 Ratings and characteristics . 15
4.3 Periodic tests . 18
4.4 Procedures for the qualification approval . 20
4.4.1 Quality conformance inspection . 20
4.4.2 Qualification approval and its maintenance . 20
5 Instructions for preparation of detail specifications (DS) . 20
5.1 General . 20
5.2 Identification of the component . 20
5.3 Performances . 21
5.4 Marking, ordering information and related matters . 21
5.5 Selection of tests, test conditions and severities . 21
5.6 Blank detail specification pro-forma for type QLI connector . 22
6 Marking . 27
6.1 Marking of component . 27
6.2 Marking and contents of package . 27
Figure 1 – Connector with socket-centre contact with 2 options (for dimensions and
key, see Table 1) . 8
Figure 2 – Detail of bayonet lock groove, option 1 (for dimensions and key, see Table 1) . 9
Figure 3 – Detail of bayonet lock groove, option 2 (for dimensions and key, see Table 1) . 9
Figure 4 – Female centre contact (for dimensions and key, see Table 1 . 10
Figure 5 – Connector with pin-centre contact (for dimensions and key, see Table 2) . 12
Figure 6 – Details of pin-centre contact (for dimensions, see Table 2) . 12
Figure 7– Gauge pin for socket-centre contact (for dimensions, see Table 3) . 14
Figure 8 – Gauge ring for socket outer contact (for dimensions, see Table 4) . 15
---------------------- Page: 8 ----------------------
SIST EN 61169-51:2015
IEC 61169-51:2015 © IEC 2015 – 3 –
Table 1 – Dimensions of connector with socket-centre contact . 11
Table 2 – Dimensions of connector with pin-centre contact . 13
Table 3 – Gauge dimensions for socket-centre contact . 14
Table 4 – Dimensions of gauge ring for socket outer contact . 15
Table 5 – Rating and characteristics . 16
Table 6 – Acceptance tests . 18
Table 7 – Periodic tests . 19
---------------------- Page: 9 ----------------------
SIST EN 61169-51:2015
– 4 – IEC 61169-51:2015 © IEC 2015
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
RADIO-FREQUENCY CONNECTORS –
Part 51: Sectional specification for
RF coaxial connectors with inner diameter
of outer conductors 13,5 mm with bayonet lock –
Characteristic impedance 50 Ω (type QLI)
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
International Standard IEC 61169-51 has been prepared by subcommittee 46F: R.F. and
microwave passive components, of IEC technical committee 46: Cables, wires, waveguides,
R.F. connectors, R.F. and microwave passive components and accessories.
The text of this standard is based on the following documents:
FDIS Report on voting
46F/295/FDIS 46F/310/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
---------------------- Page: 10 ----------------------
SIST EN 61169-51:2015
IEC 61169-51:2015 © IEC 2015 – 5 –
A list of all parts of the IEC 61169 series, under the general title: Radio-frequency connectors,
can be found on the IEC website.
The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
IMPORTANT – The 'colour inside' logo on the cover page of this publication indicates
that it contains colours which are considered to be useful for the correct
understanding of its contents. Users should therefore print this document using a
colour printer.
---------------------- Page: 11 ----------------------
SIST EN 61169-51:2015
– 6 – IEC 61169-51:2015 © IEC 2015
INTRODUCTION
The international Electrotechnical Commission (IEC) draws attention to the fact that it is
claimed that compliance with this document may involve the use of a patent concerning the
design of the connector given in 3.1.
IEC takes no position concerning the evidence, validity and scope of this patent right.
The holder of this patent right has assured the IEC that he/she is willing to negotiate licence
under reasonable and non-discriminatory terms and conditions with applicants throughout the
world. In this respect, the statement of the holders of this patent right is registered with IEC.
More detailed information may be obtained from:
Radiall SA
Mr. Pierre Bigot, RFI Division
Pierre.bigot@radiall.com
Phone:+33 47 650 0057
Z.I Centr’alp – 642 rue Emile Romanet, B.P. 35 – F-38341 Voreppe Cedex, France
Attention is drawn to the possibility that some of elements of this document may be the
subject of patent rights other than those identified above. IEC shall not be held responsible for
identifying any or all such patent rights.
ISO (www.iso.org/patents) and IEC (http://patents.iec.ch) maintain on-line data bases of
patents relevant to their standards. Users are encouraged to consult the data bases for the
most up to date information concerning patents.
---------------------- Page: 12 ----------------------
SIST EN 61169-51:2015
IEC 61169-51:2015 © IEC 2015 – 7 –
RADIO-FREQUENCY CONNECTORS –
Part 51: Sectional specification for
RF coaxial connectors with inner diameter
of outer conductors 13,5 mm with bayonet lock –
Characteristic impedance 50 Ω (type QLI)
1 Scope
This part of IEC 61169, which is a sectional specification (SS), provides information and rules
for the preparation of detail specifications (DS) for type QLI R.F. coaxial connectors with quick
lock.
The connectors are normally used with 50 Ω corrugated cable and flexible cables for middle
power applications in an operating range up to 6 GHz.
It describes the interface dimensions for general purpose connectors with gauging information
and the mandatory tests selected from IEC 61169-1 applicable to all detail specifications
relative to type QLI connectors.
This specification indicates the recommended performance characteristics to be considered
when writing a DS and covers all tests schedules and inspection requirements.
NOTE Metric dimension are original dimensions.
All un-dimensioned pictorial configurations are for reference purpose only.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and
are indispensable for its application. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any
amendments) applies.
IEC 60529, Degrees of protection provided by enclosures (IP Code)
IEC 61169-1:2013, Radio-frequency connectors – Part 1: Generic specification – General
requirements and measuring methods
IEC 62037 (all parts), Passive RF and microwave devices, intermodulation level measurement
ISO 21207, Corrosion tests in artificial atmospheres – Accelerated corrosion tests involving
alternate exposure to corrosion-promoting gases, neutral salt-spray and drying
---------------------- Page: 13 ----------------------
SIST EN 61169-51:2015
– 8 – IEC 61169-51:2015 © IEC 2015
3 Mating face and gauge information
3.1 Dimensions – General connectors
3.1.1 Connector with socket-centre contact
IEC IEC
a) Option 1 − connector for outdoor b) Option 2 − connector for indoor
(1) Reference plane
(2) Slotted and flared to meet mechanical and electrical requirements
(3) Sealing O-ring to meet required electrical and environmental performance
(4) The nut is permitted to use either option 1 or option 2 depending on outdoor or indoor use.
Figure 1 – Connector with socket-centre contact with 2 options
(for dimensions and key, see Table 1)
---------------------- Page: 14 ----------------------
SIST EN 61169-51:2015
IEC 61169-51:2015 © IEC 2015 – 9 –
IEC
(1) Reference plane
Figure 2 – Detail of bayonet lock groove, option 1 (for dimensions and key, see Table 1)
IEC
(1) Reference plane
Figure 3 – Detail of bayonet lock groove, option 2 (for dimensions and key, see Table 1)
---------------------- Page: 15 ----------------------
SIST EN 61169-51:2015
– 10 – IEC 61169-51:2015 © IEC 2015
IEC
(5) Slotted and closed to meet socket gauge test
Figure 4 – Female centre contact (for dimensions and key, see Table 1
---------------------- Page: 16 ----------------------
SIST EN 61169-51:2015
IEC 61169-51:2015 © IEC 2015 – 11 –
Table 1 – Dimensions of connector with socket-centre contact
Ref. mm Additional notes
Min. Max.
A 0,22 0,38
B 0,1 0,3
C − −
D
− −
E 18,48 18,58
F 15,2 15,28
G 6 −
H 4,1 nom.
J − −
K1 3,9 5,2
K2 5,1 5,5
L 2,45 2,6
M 0,20 0,28
N 20 35 Degree
Q 20,4 20,5
R 7,60 8,5
S 3,59 3,77
U 6,5 6,8
---------------------- Page: 17 ----------------------
SIST EN 61169-51:2015
– 12 – IEC 61169-51:2015 © IEC 2015
3.1.2 Connector with pin-centre contact
IEC
(1) Reference plane
(2) A concave depression between studs is permissible.
(3) The O-ring is optional.
Figure 5 – Connector with pin-centre contact (for dimensions and key, see Table 2)
IEC
Figure 6 – Details of pin-centre contact (for dimensions, see Table 2)
---------------------- Page: 18 ----------------------
SIST EN 61169-51:2015
IEC 61169-51:2015 © IEC 2015 – 13 –
Table 2 – Dimensions of connector with pin-centre contact
Ref. mm Additional notes
Min. Max.
A 0,07 0,23
B 0,05 0,25
D 15,02 15,08
E 18,28 18,40
F 15,30 15,40
G 4,30 4,70
H 4,1 nom.
J 2,87 2,93
K 7,00 7,30
L 2,25 2,35
M 20,10 20,25
N 6,35 6,45
P 2,40 2,60
Q 20,00 20,20
R 12,00
−
S 4,05 4,15
T 1,95
−
U 6,30 6,50
---------------------- Page: 19 ----------------------
SIST EN 61169-51:2015
– 14 – IEC 61169-51:2015 © IEC 2015
3.2 Gauges for connector with socket-centre contact
3.2.1 Centre contact
IEC
Figure 7– Gauge pin for socket-centre contact (for dimensions, see Table 3)
Table 3 – Gauge dimensions for socket-centre contact
Gauge A Gauge B
Maximum material for sizing purpose and measurement of Minimum material for measurement of minimum retention
maximum retention force force
Mass of gauge: 1,3 Kg ± 2 g Mass of gauge: 400 g ± 2 g
Ref. mm mm
Min. Max. Min. Max.
A 2,930 2,935 2,865 2,870
Material: steel, polished
Surface roughness: Ra=0,4 µm maximum
3.2.2 Test procedure
The gauge A (see Figure 7) shall be inserted into the socket-centre contact three times with a
minimum depth of 4 mm. The insertion force shall not exceed 30 N. The contact shall retain
the mass of gauge in a vertical downward position. The test also shall be carried out on
connector when the socket-centre contact is not removed.
After this, the gauge B shall be inserted in socket-centre contact. The contact shall retain the
mass the gauge in a vertical downward position. The test also shall be carried out on
connector when socket-centre contact is not removed.
---------------------- Page: 20 ----------------------
SIST EN 61169-51:2015
IEC 61169-51:2015 © IEC 2015 – 15 –
3.2.3 Gauge for outer contact
IEC
Figure 8 – Gauge ring for socket outer contact (for dimensions, see Table 4)
Table 4 – Dimensions of gauge ring for socket outer contact
Gauge B
Gauge A
Minimum material for measurement of minimum retention
Maximum material for measurement of retention force
force
Mass of gauge: 0,8 Kg ± 0,02 Kg
Mass of gauge: 400 g ± 2 g
Ref. mm mm
Min. Max. Min. Max.
A 15,45 15,55 2,865 2,870
D 15,08 15,09 2,865 2,870
E 18,2 18,4 18,2 18,4
F 15,3 15,4 15,3 15,4
T 3,0 nom. 3,0 nom.
U 7 7,2 7 7,2
Material: steel, polished
Surface roughness: Ra=0,4 µm maximum
For slotted outer contacts, a steel test ring (see Figure 8) with inner diameter A shall be
placed over the outer contact of the connector. The test ring shall uniformly meet the outer
contact when pushed no more than 3,05 mm over this contact.
4 Quality assessment procedures
4.1 General
Subclauses 4.2 to 4.4 provide recommended ratings, performance and test conditions to be
considered when writing a detail specification (DS). They also provide an appropriate
schedule of tests with minimum levels of conformance.
4.2 Ratings and characteristics
The values indicated below are recommended for type QLI connectors and are given for the
writer of the detail specification. They are applicable for the condition when the connectors
are fully mated.
---------------------- Page: 21 ----------------------
SIST EN 61169-51:2015
– 16 – IEC 61169-51:2015 © IEC 2015
Certain tests will usually not be required. When these tests are required, appropriate values
shall be entered in the detail specification at the discretion of the specification writer.
The connectors have a maximum working voltage of 1,4 kV at sea level.
Connection to the cable may be made either by crimping or soldering, depending upon
design.
Table 5 – Rating and characteristics
Test method
Remarks, deviation from
Ratings and characterisitics IEC 61169-1:2013 Value
standard test method
Subclause
Electrical
Nominal impedance
50 Ω
Frequency range DC to 6 GHz
a
9.2.1
Reflection factor
– Straight styles
≤ 0,07
– Right angle styles ≤ 0,09
– Component mounting ≤ 0,070
styles
Insertion loss < 0,05 × √ f (GHz)
b
9.2.3
Centre contact resistance
– initial
0,4 mΩ
– after tests
0,8 mΩ
b
9.2.3
Outer contact continuity
– initial 1,5 mΩ
– after tests
2,0 mΩ
Insulation resistance 9.2.5
– initial
5 000 MΩ
– after tests
c,d
Proof voltage
– sea level 9.2.6 2 500 Vrms
– at 3 000 m 9.2.6
e
9.2.7
≥ 100 dB, at
Screening effectiveness
1 GHz
≥ 90 dB, at
3 GHz
Intermodulation level IEC 62037 Over –163 dBc
Transient current withstanding
– centre contact
5 KA
– with 10/350 µs pulse
– with 8/20 µs pulse 20 KA
Transient current withstanding
– outer contact
20 KA
– with 10/350 µs pulse
80 KA
– with 8/20 µs pulse
Power test at sea level
---------------------- Page: 22 ----------------------
SIST EN 61169-51:2015
IEC 61169-51:2015 © IEC 2015 – 17 –
Test method
Remarks, deviation from
Ratings and characterisitics IEC 61169-1:2013 Value
standard test method
Subclause
– average 1 KW, at 2 GHz
– peak 15 KW, at 2 GHz
Mechanical
Centre contact captivation 9.3.5 Maximum displacement of 0,25
mm in any directions
– axial force 50 N
– torque 20 N.cm
Engagement and separation 9.3.6
force
– axial force (engagement) 50 N
– axial force (separation) 40 N
– torque 2 N.m
Gauge retention force 9.3.4
– centre contact 4 N to 15 N
– outer contact 10 to 40 N
– torque 2 N.m
Mechanical tests on cable
fixing
– cable pulling 9.3.8 ≥ 250 N
– cable bending 9.3.9 Bending number: 10
≥ 150 N
Bending angle: 90°
– cable torsion 9.3.10
≥ 2,5 N.m
Tensile strength of coupling 9.3.11 445 N
mechanism
Bending moment of coupling 9.3.12 na
mechanism
²
Vibration 9.3.3 100 m/s 10 g
n
10 Hz to 500 Hz
²
Shock 9.3.14 500 m/s 50 g
n
½ sine wave
6 ms
Endurance
Mechanical endurance 9.3.15 100 operations
f
9.4.5 1 000 h at For BZ4 center socket contact,
High temperature endurance
155 °C upper temperature is limited to
120 °C
Environmental
Climatic category
– operation 55/85/21
– storage 9.4.2 65/155/56 For BZ4 center socket contact,
upper temperature is limited to
120 °C
Sealing IEC 60529 IP67
Salt mist 9.4.10 96 h spray
Corrosion ISO 21207 Method B