Connectors for electronic equipment - Product requirements - Part 3-120: Rectangular connectors - Detail specification for rewirable power connectors with snap locking for rated voltage of 250 v d.c. and rated current of 30 a (IEC 61076-3-120:2016)

This part of IEC 61076-3 describes a 2 pole 30 A rectangular power connector with snap
locking (hereinafter shortly referred to as connector), including overall dimensions, interface
dimensions, technical characteristics, performance requirements and test methods.
The products covered by this detail specification are connectors without breaking capacity
according to IEC 61984:2008 which are mainly for use in DC power distribution equipment in
the telecommunications field, such as in outdoor telecom modules, distributed frames, etc.

Steckverbinder für elektronische Einrichtungen - Produktanforderungen - Teil 3-120: Rechteckige Steckverbinder - Bauartspezifikation für wiederanschließbare Leistungssteckverbinder mit Rastverriegelung für 250 V Bemessungsgleichspannung und einen Bemessungsstrom von 30 A

Connecteurs pour équipements électroniques - Exigences de produit - Partie 3-120: Connecteurs rectangulaires - Spécification particulière pour connecteurs de puissance démontables à encliquetage pour une tension continue assignée de 250 V et un courant assigné de 30 A

L'IEC 61076-3-120:2016 décrit un connecteur de puissance démontable rectangulaire à encliquetage à deux pôles pour un courant de 30 A (désigné ci-après "connecteur"). Elle inclut les dimensions hors-tout, les dimensions d'interface, les caractéristiques techniques, les exigences de performances et les méthodes d'essai.
Les produits couverts par la présente spécification particulière sont les connecteurs sans pouvoir de coupure conformes à l'IEC 61984:2008 utilisés principalement dans des équipements de distribution d'alimentation en courant continu dans le domaine des télécommunications, par exemple dans des modules extérieurs de télécommunication, des répartiteurs, etc.
Mots clés: connecteurs, connecteurs rectangulaires, puissance démontables à encliquetage

Konektorji za elektronsko opremo - Zahteve za izdelek - 3-120. del: Pravokotni konektorji - Podrobna specifikacija za močnostne konektorje s kabelskimi priključki za naznačeno enosmerno napetost 250 V in naznačeni tok 30 A (IEC 61076-3-120:2016)

Ta del standarda IEC 61076-3 opisuje 2-polni pravokotni konektor 30 A s kabelskimi priključki (v nadaljevanju krajše »konektor«), vključno s skupnimi dimenzijami, dimenzijami vmesnika, tehničnimi lastnostmi, zahtevami glede zmogljivosti in preskusnimi metodami.
Proizvodi, zajeti s to podrobno specifikacijo, so konektorji brez zmogljivosti prekinitve v skladu s standardom IEC 61984:2008, ki se uporabljajo predvsem v distribucijski opremi za enosmerni tok na področju telekomunikacij, kot so zunanji telekomunikacijski moduli, porazdeljeni bloki itd.

General Information

Status
Published
Publication Date
08-Jan-2017
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
04-Jan-2017
Due Date
11-Mar-2017
Completion Date
09-Jan-2017

Buy Standard

Standard
EN 61076-3-120:2017
English language
29 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.HOVNLPLConnectors for electronic equipment - Product requirements - Part 3-120: Rectangular connectors - Detail specification for rewirable power connectors with snap locking for rated voltage of 250 v d.c. and rated current of 30 a (IEC 61076-3-120:2016)31.220.10Plug-and-socket devices. ConnectorsICS:Ta slovenski standard je istoveten z:EN 61076-3-120:2016SIST EN 61076-3-120:2017en01-februar-2017SIST EN 61076-3-120:2017SLOVENSKI
STANDARD



SIST EN 61076-3-120:2017



EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 61076-3-120
December 2016 ICS 31.220.10
English Version
Connectors for electronic equipment - Product requirements - Part 3-120: Rectangular connectors - Detail specification for rewirable power connectors with snap locking for rated voltage of 250 V d.c. and rated current of 30 A (IEC 61076-3-120:2016)
Connecteurs pour équipements électroniques - Exigences de produit - Partie 3-120: Connecteurs rectangulaires - Spécification particulière pour connecteurs de puissance démontables à encliquetage pour une tension continue assignée de 250 V et un courant assigné de 30 A (IEC 61076-3-120:2016)
Steckverbinder für elektronische Einrichtungen - Produktanforderungen - Teil 3-120: Rechteckige Steckverbinder - Bauartspezifikation für wiederanschließbare Leistungssteckverbinder mit Rastverriegelung für 250 V Bemessungsgleichspannung und einen Bemessungsstrom von 30 A (IEC 61076-3-120:2016) This European Standard was approved by CENELEC on 2016-09-29. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique Europäisches Komitee für Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17,
B-1000 Brussels © 2016 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 61076-3-120:2016 E SIST EN 61076-3-120:2017



EN 61076-3-120:2016 2 European foreword The text of document 48B/2498/FDIS, future edition 1 of IEC 61076-3-120, prepared by SC 48B "Electrical connectors", of IEC/TC 48 "Electrical connectors and mechanical structures for electrical and electronic equipment" was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 61076-3-120:2016. The following dates are fixed: • latest date by which the document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2017-06-29 • latest date by which the national standards conflicting with the document have to be withdrawn (dow) 2019-09-29
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such patent rights. Endorsement notice The text of the International Standard IEC 61076-3-120:2016 was approved by CENELEC as a European Standard without any modification. In the official version, for Bibliography, the following notes have to be added for the standards indicated: IEC 60352-7 NOTE Harmonized as EN 60352-7. IEC 60512-1-100 NOTE Harmonized as EN 60512-1-100. IEC 60999-2:2003 NOTE Harmonized as EN 60999-2:2003 (not modified). ISO 11469:2000 NOTE Harmonized as EN ISO 11469:2000 (not modified). SIST EN 61076-3-120:2017



EN 61076-3-120:2016 3 Annex ZA (normative)
Normative references to international publications with their corresponding European publications The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available here: www.cenelec.eu.
Publication Year Title EN/HD Year IEC 60050-581 2008
International Electrotechnical Vocabulary (IEV) - Part 581: Electromechanical components for electronic equipment - -
IEC 60068-1 -
Environmental testing - Part 1: General and guidance EN 60068-1 -
IEC 60228 2004
Conductors of insulated cables EN 60228 2005
- -
+ corr. May 2005
IEC 60352 series
Solderless connections EN 60352 series
IEC 60512 series
Connectors for electronic equipment - Tests and measurements EN 60512 series
IEC 60512-1-2 2002
Connectors for electronic equipment - Tests and measurements - Part 1-2: General examination - Test 1b: Examination of dimension and mass EN 60512-1-2 2002
IEC 60999-1 1999
Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm² up to 35 mm² (included) EN 60999-1 2000
IEC 61076-1 2006
Connectors for electronic equipment - Product requirements - Part 1: Generic specification EN 61076-1 2006
IEC 61076-3 2008
Connectors for electronic equipment - Product requirements - Part 3: Rectangular connectors - Sectional specification EN 61076-3 2008
SIST EN 61076-3-120:2017



EN 61076-3-120:2016 4 Publication Year Title EN/HD Year IEC 61984 2008
Connectors - Safety requirements and tests EN 61984 2009
IEC 62430 -
Environmentally conscious design for electrical and electronic products EN 62430 -
IEC Guide 109 -
Environmental aspects - Inclusion in electrotechnical product standards - -
SIST EN 61076-3-120:2017



IEC 61076-3-120 Edition 1.0 2016-08 INTERNATIONAL STANDARD NORME INTERNATIONALE Connectors for electronic equipment – Product requirements –
Part 3-120: Rectangular connectors – Detail specification for rewirable power connectors with snap locking for rated voltage of 250 V d.c. and rated current of 30 A
Connecteurs pour équipements électroniques – Exigences de produit –
Partie 3-120: Connecteurs rectangulaires – Spécification particulière pour connecteurs de puissance démontables à encliquetage pour une tension continue assignée de 250 V et un courant assigné de 30 A
INTERNATIONAL ELECTROTECHNICAL COMMISSION COMMISSION ELECTROTECHNIQUE INTERNATIONALE
ICS 31.220.10
ISBN 978-2-8322-3555-3
® Registered trademark of the International Electrotechnical Commission
Marque déposée de la Commission Electrotechnique Internationale ®
Warning! Make sure that you obtained this publication from an authorized distributor.
Attention! Veuillez vous assurer que vous avez obtenu cette publication via un distributeur agréé. SIST EN 61076-3-120:2017



– 2 – IEC 61076-3-120:2016 © IEC 2016 CONTENTS FOREWORD . 4 INTRODUCTION . 7 1 Scope . 8 2 Normative references. 8 3 Terms and definitions . 9 4 Technical information . 9 4.1 Ratings and characteristics . 9 4.2 Performance levels . 9 4.3 Compatibility levels . 9 4.4 Classification into climatic categories . 9 4.5 Clearance and creepage distances . 9 4.6 Current-carrying capacity . 10 4.7 Marking . 10 5 Dimensional information . 10 5.1 General . 10 5.2 Isometric view and common features (see Figure 1 and Figure 2) . 10 5.3 Fixed connectors (see Figure 3 and Table 2) . 11 5.3.1 Dimensions . 11 5.3.2 Terminations . 12 5.4 Free connectors (see Figure 4 and Table 3) . 13 5.4.1 Dimensions . 13 5.4.2 Terminations . 14 5.5 Accessories . 14 5.6 Mounting information . 14 5.7 Gauges . 14 5.7.1 Sizing gauges and retention force gauges (see Figure 5 and Table 4) . 14 6 Characteristics . 15 6.1 Classification into climatic categories . 15 6.2 Electrical characteristics . 15 6.2.1 Clearance and creepage distance . 15 6.2.2 Voltage proof . 15 6.2.3 Contact resistance . 15 6.2.4 Insulation resistance . 16 6.2.5 Temperature rise . 16 6.3 Mechanical characteristics . 16 6.3.1 Mechanical operation . 16 6.3.2 Insertion and withdrawal forces . 16 6.3.3 Contact retention in insert . 16 6.3.4 Polarizing and coding method . 17 6.3.5 Effectiveness of connector coupling devices . 17 6.3.6 Conductor secureness. 17 6.4 Dynamic stress test . 17 6.4.1 Vibration (sine) . 17 6.4.2 Shock . 17 6.5 Climatic test . 18 6.5.1 Damp heat steady state. 18 SIST EN 61076-3-120:2017



IEC 61076-3-120:2016 © IEC 2016 – 3 –
6.5.2 Rapid change of temperature . 18 6.5.3 Salt spray . 18 6.5.4 Dry heat . 18 6.6 Environmental aspects . 18 6.6.1 Marking of insulation material (plastic) . 18 6.6.2 Design/use of material . 18 7 Test schedule . 19 7.1 General . 19 7.2 Test schedules . 19 7.2.1 Basic (minimum) test schedule . 19 7.2.2 Full test schedule . 19 7.3 Test procedures and measurement methods . 24 7.4 Pre-conditioning . 24 7.5 Wiring and mounting of test specimens . 24 7.5.1 Wiring . 24 7.5.2 Mounting . 24 Bibliography . 25
Figure 1 – Isometric view of free connector . 10 Figure 2 – Isometric view of fixed connector . 10 Figure 3 – Fixed connector . 11 Figure 4 – Free connector . 13 Figure 5 – Gauge . 15
Table 1 – Climatic categories . 9 Table 2 – Dimensions of the fixed connector . 12 Table 3 – Dimensions of the free connector . 14 Table 4 – Gauge dimensions . 15 Table 5 – Conductor secureness test . 17 Table 6 – Number of test specimens . 19 Table 7 – Test group P . 19 Table 8 – Test group AP . 20 Table 9 – Test group BP . 21 Table 10 – Test group CP . 22 Table 11 – Test group DP . 22 Table 12 – Test group EP . 23 Table 13 – Test group JP . 23 Table 14 – Test group KP . 24
SIST EN 61076-3-120:2017



– 4 – IEC 61076-3-120:2016 © IEC 2016 INTERNATIONAL ELECTROTECHNICAL COMMISSION ____________
CONNECTORS FOR ELECTRONIC EQUIPMENT –
PRODUCT REQUIREMENTS –
Part 3-120: Rectangular connectors – Detail specification
for rewirable power connectors with snap locking for rated voltage
of 250 V d.c. and rated current of 30 A
FOREWORD 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work. International, governmental and non-governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for Standardization (ISO) in accordance with conditions determined by agreement between the two organizations. 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any misinterpretation by any end user. 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications transparently to the maximum extent possible in their national and regional publications. Any divergence between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter. 5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any services carried out by independent certification bodies. 6) All users should ensure that they have the latest edition of this publication. 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and members of its technical committees and IEC National Committees for any personal injury, property damage or other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is indispensable for the correct application of this publication. 9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent rights. IEC shall not be held responsible for identifying any or all such patent rights. International Standard IEC 61076-3-120 has been prepared by subcommittee 48B: Electrical connectors, of IEC technical committee 48: Electrical connectors and mechanical structures for electrical and electronic equipment. The text of this standard is based on the following documents: FDIS Report on voting 48B/2498/FDIS 48B/2511/RVD
Full information on the voting for the approval of this standard can be found in the report on voting indicated in the above table. SIST EN 61076-3-120:2017



IEC 61076-3-120:2016 © IEC 2016 – 5 –
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2. The committee has decided that the contents of this publication will remain unchanged until the stability date indicated on the IEC website under "http://webstore.iec.ch" in the data related to the specific publication. At this date, the publication will be
• reconfirmed, • withdrawn, • replaced by a revised edition, or • amended.
SIST EN 61076-3-120:2017



– 6 – IEC 61076-3-120:2016 © IEC 2016
The International Electrotechnical Commission IEC SC 48B —Electrical connectors IEC 61076-3-120 Detail specification in accordance with IEC 61076-3
Rewirable power connectors with snap locking for rated voltage of 250 V d.c. and rated current of 30 A
Fixed and free connectors, for telecommunication equipment
IEC SIST EN 61076-3-120:2017



IEC 61076-3-120:2016 © IEC 2016 – 7 –
INTRODUCTION The International Electrotechnical Commission (IEC) draws attention to the fact that it is claimed that compliance with this document may involve the use of a patent concerning connectors given in this specification. The IEC takes no position concerning the evidence, validity and scope of this patent right. The holder of this patent right has assured the IEC that he/she is willing to give free licences with applicants throughout the world. In this respect, the statement of the holder of this patent right is registered with the IEC. Information may be obtained from: Sichuan Huafeng Enterprise Group Co., Ltd. Product and Market Planning Department No.36 Yuejin Road, Mianyang, Sichuan, China Telephone: 0086-816-231 1322 FAX: 0086-816-233 2716 Email: pangbin@huafeng796.com Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights other than those identified above. IEC shall not be held responsible for identifying any or all such patent rights. ISO (www.iso.org/patents) and IEC (http://patents.iec.ch) maintain on-line data bases of patents relevant to their standards. Users are encouraged to consult the data bases for the most up to date information concerning patents.
SIST EN 61076-3-120:2017



– 8 – IEC 61076-3-120:2016 © IEC 2016 CONNECTORS FOR ELECTRONIC EQUIPMENT –
PRODUCT REQUIREMENTS –
Part 3-120: Rectangular connectors – Detail specification
for rewirable power connectors with snap locking for rated voltage
of 250 V d.c. and rated current of 30 A
1 Scope This part of IEC 61076-3 describes a 2 pole 30 A rectangular power connector with snap locking (hereinafter shortly referred to as connector), including overall dimensions, interface dimensions, technical characteristics, performance requirements and test methods. The products covered by this detail specification are connectors without breaking capacity according to IEC 61984:2008 which are mainly for use in DC power distribution equipment in the telecommunications field, such as in outdoor telecom modules, distributed frames, etc. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60050-581:2008, International Electrotechnical Vocabulary – Part 581: Electro-mechanical components for electronic equipment IEC 60068-1, Environmental testing – Part 1: General and guidance IEC 60228:2004, Conductors of insulated cables IEC 60352 (all parts), Solderless connections IEC 60512 (all parts), Connectors for electronic equipment – Tests and measurements IEC 60512-1-2:2002, Connectors for electronic equipment – Tests and measurements – Part 1-2: General examination IEC 60999-1:1999, Connecting devices – Electrical copper conductors – Safety requirements for screw type and screwless-type clamping units – Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm2 up to 35 mm2 (included) IEC 61076-1:2006, Connectors for electronic equipment – Part 1: Generic specification IEC 61076-3:2008, Connectors for electronic equipment – Product requirements – Part 3: Rectangular connectors – Sectional specification IEC 61984:2008, Connectors – Safety requirements and tests IEC 62430, Environmentally conscious design for electrical and electronic products SIST EN 61076-3-120:2017



IEC 61076-3-120:2016 © IEC 2016 – 9 –
IEC Guide 109, Environmental aspects – Inclusion in electrotechnical product standards 3 Terms and definitions For the purposes of this document, the terms and definitions given in IEC 60050-581 apply. 4 Technical information 4.1 Ratings and characteristics Connectors according this specification are connectors without breaking capacity (COC) according to IEC 61984. Therefore, they are not intended to be engaged or disengaged in normal use when live or under load, if not otherwise specified by the manufacturer. Rated voltage: 250 V d.c., overvoltage category: 4 kV, pollution degree: 3. Rated current: 30 A Insulation resistance: ≥1 000 MΩ. Suitable wire: cross-sectional area 1 mm2 to 4 mm2, single-core or multi-core. 4.2 Performance levels Performance level for this connector is 1. 4.3 Compatibility levels Connectors according to this standard are intermateable according to IEC 61076-1:2006. 4.4 Classification into climatic categories Conditions: according to IEC 60068-1 and Table 1. Table 1 – Climatic categories Climatic category Lower temperature Upper temperature Damp heat steady state
°C °C (days) 55/125/4 –55 125 4
4.5 Clearance and creepage distances Clearance and creepage distances shall be measured according to IEC 60512-1-2 with the following additional requirement. For these connectors clearance and creepage distances shall be measured only in mated position (connector without breaking capacity as defined in IEC 61984). Minimum clearance: 3,0 mm. Minimum creepage distance: 4,0 mm. SIST EN 61076-3-120:2017



– 10 – IEC 61076-3-120:2016 © IEC 2016 4.6 Current-carrying capacity The current-carrying capacity shall be measured according to IEC 60512, Test 5b and stated by the manufacturer. 4.7 Marking The marking of the connector and the package shall be in accordance with 2.7 of IEC 61076-1:2006. NOTE Additional marking may be required, see 6.6.1. 5 Dimensional information 5.1 General Dimensions are given in millimetres, drawings are shown in third angle projection. The shape of the connectors may deviate from those given in the following drawings as long as the specified dimensions are not influenced. For safety aspects IEC 61984 shall be considered unless otherwise specified. Missing dimensions shall be chosen according to the common characteristics and intended use. 5.2 Isometric view and common features (see Figure 1 and Figure 2)
Figure 1 – Isometric view of free connector
Figure 2 – Isometric view of fixed connector IEC IEC SIST EN 61076-3-120:2017



IEC 61076-3-120:2016 © IEC 2016 – 11 –
5.3 Fixed connectors (see Figure 3 and Table 2) 5.3.1 Dimensions
Figure 3 – Fixed connector IEC JViewA-AKM0,050,05YEIHBGQ0,05X0,05YAANDetail1Detail1FCAXY0,05YLDetail2Detail2DPORS0,05YSIST EN 61076-3-120:2017



– 12 – IEC 61076-3-120:2016 © IEC 2016 Table 2 – Dimensions of the fixed connector Dimensions in mm Letter Minimum Nominal Maximum A 22 22 22,3 B 7,15 7,2 7,25 C 1,15 1,2 1,25 D 0,765 0,8 0,835 E 15,7 15,8 15,9 F 7,6 7,8 7,8 G 5,95 6 6,05 H 9,3 9,3 9,45 I 0,55 0,6 0,65 J R1,5 R1,6 R1,7 K 12,85 13 13,15 L – – 9,5 M 22,62 22,7 22,78 N 1,9 2 2 O 7,5 7,5 7,6 P 23,55 23,6 23,65 Q – 3 – R R0,25 R0,3 R0,35 S 6 6 6,05
5.3.2 Terminations Any termination type in accordance with the relevant IEC standards may apply. SIST EN 61076-3-120:2017



IEC 61076-3-120:2016 © IEC 2016 – 13 –
5.4 Free connectors (see Figure 4 and Table 3) 5.4.1 Dimensions
Figure 4 – Free connector IEC KDetail1Detail2Detail1Detail2OQSEABCFGHXY0,08X0,05X0,08YIJMR0,1Y0,1Y0,1YDNPLSIST EN 61076-3-120:2017



– 14 – IEC 61076-3-120:2016 © IEC 2016 Table 3 – Dimensions of the free connector Dimensions in mm Letter Minimum Nominal Maximum A 21,65 21,8 21,95 B 7,12 7,2 7,28 C 1,35 1,4 1,5 D 0,9
...

Questions, Comments and Discussion