Stationary waste containers up to 5 000 l, top lifted and bottom emptied - Part 1: General requirements

This document specifies requirements of containers, top lifted and bottom emptied, used for collection of solid non hazardous wastes, with capacity up to 5 000 l.
The document specifies the general characteristics of such containers and their accessories, the test methods and the safety requirements.
Reference to part 2 for additional requirements for underground or partly underground.

Stationäre Abfallsammelbehälter bis 5 000 l, mit Behälteraufnahme an der Oberseite und Bodenentleerung - Teil 1: Allgemeine Anforderungen

Dieses Dokument legt Anforderungen an stationäre Abfallsammelbehälter mit einem Volumen bis 5 000 l, mit Behälteraufnahme an der Oberseite und Bodenentleerung, für die Sammlung von festem, nicht gefährlichem Abfall fest.
Das Dokument legt die allgemeinen Eigenschaften solcher Behälter und deren Zubehör, Prüfverfahren und Sicherheitsanforderungen fest.
Verwiesen wird auf Teil 2 bezüglich zusätzlicher Anforderungen für unterirdische und teilweise unterirdische Systeme.

Conteneurs fixes de capacité 5 000 l, levés par le haut et vidés par le bas Partie 1: Spécifications générales

La présente Norme européenne spécifie les exigences qui s’appliquent aux conteneurs fixes, levés par le haut et vidés par le bas, utilisés pour la collecte de déchets solides non dangereux, d’une capacité maximale de 5000 l.
Elle spécifie les caractéristiques générales de ce type de conteneurs et de leurs accessoires, ainsi que les méthodes d’essai et les exigences de sécurité qui leur sont applicables.

Nepremični zabojniki za odpadke do 5000 l, ki se dvigujejo zgoraj in praznijo spodaj - 1. del: Splošne zahteve

Ta dokument opredeljuje zahteve za zabojnike, ki se dvigujejo zgoraj in praznijo spodaj in se uporabljajo za zbiranje trdnih nenevarnih odpadkov, s kapaciteto do 5.000 l. Dokument določa splošne značilnosti takšnih zabojnikov in njihove dodatke, metode preskušanja in varnostne zahteve. Sklic na drugi del za dodatne zahteve za podzemne ali delno podzemne.

General Information

Status
Withdrawn
Publication Date
05-Aug-2008
Withdrawal Date
06-Aug-2019
Technical Committee
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
25-Jul-2019
Due Date
17-Aug-2019
Completion Date
07-Aug-2019

Relations

Buy Standard

Standard
EN 13071-1:2008
English language
20 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 13071-1:2008
01-september-2008
1DGRPHãþD
SIST EN 13071:2004
1HSUHPLþQL]DERMQLNL]DRGSDGNHGRONLVHGYLJXMHMR]JRUDMLQSUD]QLMR
VSRGDMGHO6SORãQH]DKWHYH
Stationary waste containers up to 5 000 l, top lifted and bottom emptied - Part 1: General
requirements
Stationäre Abfallsammelbehälter bis 5 000 l, mit Behälteraufnahme an der Oberseite und
Bodenentleerung - Teil 1: Allgemeine Anforderungen
Conteneurs fixes de capacité 5 000 l, levés par le haut et vidés par le bas Partie 1:
Spécifications générales
Ta slovenski standard je istoveten z: EN 13071-1:2008
ICS:
13.030.40 Naprave in oprema za Installations and equipment
odstranjevanje in obdelavo for waste disposal and
odpadkov treatment
SIST EN 13071-1:2008 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 13071-1:2008

---------------------- Page: 2 ----------------------

SIST EN 13071-1:2008
EUROPEAN STANDARD
EN 13071-1
NORME EUROPÉENNE
EUROPÄISCHE NORM
June 2008
ICS 13.030.40 Supersedes EN 13071:2002
English Version
Stationary waste containers up to 5 000 l, top lifted and bottom
emptied - Part 1: General requirements
Conteneurs fixes de capacité 5 000 l, levés par le haut et Stationäre Abfallsammelbehälter bis 5 000 l, mit
vidés par le bas - Partie 1: Spécifications générales Behälteraufnahme an der Oberseite und Bodenentleerung -
Teil 1: Allgemeine Anforderungen
This European Standard was approved by CEN on 18 April 2008.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the CEN Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the
official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,
France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,
Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: rue de Stassart, 36  B-1050 Brussels
© 2008 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 13071-1:2008: E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------

SIST EN 13071-1:2008
EN 13071-1:2008 (E)
Contents
Page
Foreword.4
1 Scope .5
2 Normative references .5
3 Terms and definitions .5
4 General requirements.6
4.1 Design .6
4.2 Filling aperture height .7
4.3 Total height.7
4.4 External surfaces/edges .7
4.5 Lifting connection position.7
4.6 Total permissible mass .7
4.7 Total usable volume .7
4.8 Waste spillage.7
5 Test conditions .7
5.1 General.7
5.2 Temperature requirements .7
5.3 Waste density.8
6 Test methods.8
6.1 General.8
6.2 Test methods on empty containers .8
6.2.1 Stability test.8
6.2.2 Resistance to interior impacts .8
6.2.3 Free fall test.11
6.2.4 Resistance of the roof .12
6.3 Tests methods on loaded containers .12
6.3.1 Resistance to exterior impacts.12
6.3.2 Emptying device/Locking system.14
6.3.3 Mechanical resistance of the lifting components .15
6.4 Measurement of the sound level emitted by falling glass inside the containers.16
6.5 Corrosion.16
6.6 Weathering (for thermoplastics only).16
6.6.1 Requirement.16
6.6.2 Procedure .16
6.7 Sequence of tests .16
7 Data sheet.17
8 Marking .17
9 Test report .18
Annex A (normative)  Weathering tests.19
Bibliography .20

Figures
Figure 1 — Description of the guiding tube and position 1 according to the slope of the filling aperture.10
Figure 2 — Slant of positions 2 and 5 in relation to position 1.11
2

---------------------- Page: 4 ----------------------

SIST EN 13071-1:2008
EN 13071-1:2008 (E)
Figure 3 — Exterior impact test using the incline plan (informative).13
Figure 4 — Determination of lateral impact directions according to the shapes of the containers .14

Tables
Table 1 — Sequence of the tests.17

3

---------------------- Page: 5 ----------------------

SIST EN 13071-1:2008
EN 13071-1:2008 (E)
Foreword
This document (EN 13071-1:2008) has been prepared by Technical Committee CEN/TC 183 “Waste Management”,
the secretariat of which is held by DIN.
This European Standard shall be given the status of a national standard, either by publication of an identical text or
by endorsement, at the latest by December 2008, and conflicting national standards shall be withdrawn at the latest
by December 2008.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights.
CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights.
This document, together with EN 13071-2:2008, supersedes EN 13071:2002.
Part 1 covers the requirements for stationary waste containers up to 5 000 l, top lifted and bottom emptied. Some
technical changes respect to the previous edition, EN 13071:2002, address:
a) the minimum capacity of 80 l which has been deleted;
b) the definitions of, and general requirements for Type A and Type B containers;
c) test conditions including a new test on the resistance of the roof;
d) changes to data sheet, marking and test report;
e) deletion of Annex A dealing with the noise test method for containers for waste glass collection for Type A and
Type B, with volumes greater than or equal to 500 l.
Part 2 covers additional requirements for underground or partly underground containers.
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries
are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark,
Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta,
Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United
Kingdom.

4

---------------------- Page: 6 ----------------------

SIST EN 13071-1:2008
EN 13071-1:2008 (E)
1 Scope
This European Standard specifies requirements of stationary containers, top lifted and bottom emptied, used for
collection of solid non-hazardous wastes, with capacity up to 5 000 l.
This European Standard specifies the general characteristics of such containers and their accessories, the test
methods and the safety requirements.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated references,
only the edition cited applies. For undated references, the latest edition of the referenced document (including any
amendments) applies.
EN 10327, Continuously hot-dip coated strip and sheet of low carbon steels for cold forming - Technical delivery
conditions
EN 22248, Packaging – Complete, filled transport packages – Vertical impact test by dropping (ISO 2248:1985)
EN ISO 105–B02, Textiles - Tests for colour fastness - Part B02: Colour fastness to artificial light: Xenon arc fading
lamp test (ISO 105-B02:1994, including amendment 1:1998)
EN ISO 1461, Hot dip galvanized coatings on fabricated iron and steel articles – Specifications and tests methods
(ISO 1461:1999)
EN ISO 2244, Packaging - Complete, filled transport packages and unit loads - Horizontal impact tests
(ISO 2244:2000)
EN ISO 4892-2, Plastics – Methods of exposure to laboratory light sources – Part 2: Xenon-arc lamps (ISO 4892-
2:2006)
ISO 48, Rubber, vulcanized or thermoplastic – Determination of hardness (hardness between 10 IRHD and
100 IRHD)
ISO 2081, Metallic coatings – Electroplated coatings of zinc on iron or steel
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1
dead mass
mass of the empty container including all attached components lifted together
NOTE Dead mass is expressed in kilograms.
3.2
emptying device
part of the structure of the container to allow it to be emptied
3.3
emptying hatch
opening parts, if present, at the bottom of the container that enables it to be emptied
3.4
lifting connection
structure fitted to the container to allow lifting and placing
5

---------------------- Page: 7 ----------------------

SIST EN 13071-1:2008
EN 13071-1:2008 (E)
3.5
locking system
structure to maintain the emptying device closed
3.6
nominal load
load mass calculated from the container's nominal volume and the waste density
3.7
nominal volume
volume declared by the manufacturer
3.8
test load
specific load defined and used in each test
3.9
total permissible mass
nominal load plus the dead mass of the container including all attached components lifted together
3.10
usable volume
volume of the inside of the container beneath the bottom of the filling aperture
3.11
filling aperture height
vertical distance between ground level and the bottom of the filling aperture(s)
3.12
total height
vertical distance between the bottom of the container when opened and the top of the lifting connection
3.13
container base dimensions
horizontal dimensions of the bottom of the container including all attached components lifted together
3.14
roof
the top surface of the container or housing
3.15
type A container
container having maximum base dimensions of 2 200 mm x 3 000 mm
3.16
type B container
container having maximum base dimensions of 1 950 mm x 1 950 mm with the emptying device in normal open
position
4 General requirements
4.1 Design
The container shall be capable of being immobilised by device or by design.
The container shall be constructed so that when it is loaded or unloaded with a nominal load, it fits on a designated
lifting device. It shall be safely locked to the lifting accessory during the lifting operation.
6

---------------------- Page: 8 ----------------------

SIST EN 13071-1:2008
EN 13071-1:2008 (E)
The container shall not include any element that will result in collected materials being retained thereby
compromising complete emptying.
Filling apertures shall be designed to prevent injuries to users in normal use. In addition, filling apertures shall be
designed so that they prevent any person falling accidentally into the container. For round filling aperture having a
diameter less than 200 mm or rectangular ones with one dimension less than 150 mm, no specific design is required.
Filling apertures for the deposit of glass shall be designed in such a way as to avoid fragments or any other debris
coming out of the container.
The container shall be constructed such that it can be easily dismantled at its end of life. Materials shall be marked in
accordance with ISO standards.
4.2 Filling aperture height
Filling aperture height shall be 1 700 mm maximum. Where fitted, the filling aperture height for disabled persons shall
be 1 200 mm maximum.
4.3 Total height
Total height shall be 6 000 mm maximum.
4.4 External surfaces/edges
Sharp edges shall be avoided in all cases. Rounded edges with a radius more than 1,4 mm are not
...