Electrical relays - Tests and Measurements - Part 7-11: Enclosure Protection and Degree of Protection

Elektrische Relais - Mess- und Prüfverfahren – Teil 11: Gehäuse und Schutzart

Relais électriques - Essais et mesurages - Partie 11: Protection des enveloppes et degré de protection

Električni releji - Preskusi in meritve - 7-11. del: Zaščita ohišja in stopnja zaščite

General Information

Status
Not Published
Public Enquiry End Date
31-Oct-2023
Current Stage
5020 - Formal vote (FV) (Adopted Project)
Start Date
01-Aug-2024
Due Date
19-Sep-2024

Buy Standard

Draft
prEN IEC 61810-7-11:2023
English language
13 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
oSIST prEN IEC 61810-7-11:2023
01-oktober-2023
Električni releji - Preskusi in meritve - 7-11. del: Zaščita ohišja in stopnja zaščite
Electrical relays - Tests and Measurements - Part 7-11: Enclosure Protection and
Degree of Protection
Ta slovenski standard je istoveten z: prEN IEC 61810-7-11:2023
ICS:
29.120.70 Releji Relays
oSIST prEN IEC 61810-7-11:2023 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

oSIST prEN IEC 61810-7-11:2023

oSIST prEN IEC 61810-7-11:2023

94/934/CDV
COMMITTEE DRAFT FOR VOTE (CDV)
PROJECT NUMBER:
IEC 61810-7-11 ED1
DATE OF CIRCULATION: CLOSING DATE FOR VOTING:
2023-08-18 2023-11-10
SUPERSEDES DOCUMENTS:
94/828/CD, 94/918/CC
IEC TC 94 : ELECTRICAL RELAYS
SECRETARIAT: SECRETARY:
Austria Mr Bernhard Spalt
OF INTEREST TO THE FOLLOWING COMMITTEES: PROPOSED HORIZONTAL STANDARD:

Other TC/SCs are requested to indicate their interest, if
any, in this CDV to the secretary.
FUNCTIONS CONCERNED:
EMC ENVIRONMENT QUALITY ASSURANCE SAFETY
SUBMITTED FOR CENELEC PARALLEL VOTING NOT SUBMITTED FOR CENELEC PARALLEL VOTING
Attention IEC-CENELEC parallel voting
The attention of IEC National Committees, members of
CENELEC, is drawn to the fact that this Committee Draft
for Vote (CDV) is submitted for parallel voting.
The CENELEC members are invited to vote through the
CENELEC online voting system.
This document is still under study and subject to change. It should not be used for reference purposes.
Recipients of this document are invited to submit, with their comments, notification of any relevant patent rights of
which they are aware and to provide supporting documentation.
Recipients of this document are invited to submit, with their comments, notification of any relevant “In Some
Countries” clauses to be included should this proposal proceed. Recipients are reminded that the CDV stage is
the final stage for submitting ISC clauses. (SEE AC/22/2007 OR NEW GUIDANCE DOC).

TITLE:
Electrical relays – Tests and Measurements – Part 7-11: Enclosure Protection and Degree of
Protection
PROPOSED STABILITY DATE: 2025
NOTE FROM TC/SC OFFICERS:
electronic file, to make a copy and to print out the content for the sole purpose of preparing National Committee positions.
You may not copy or "mirror" the file or printed version of the document, or any part of it, for any other purpose without
permission in writing from IEC.

oSIST prEN IEC 61810-7-11:2023
– 2 – IEC CDV 61810-7-11:2023 © IEC 2023
1 CONTENTS
2 FOREWORD . 3
3 1 Scope . 5
4 2 Normative references . 5
5 3 Terms and definitions . 5
6 4 Test procedure . 6
7 5 Evaluation . 9
8 ANNEX A (normative) Procedure 2: Helium Sniffer test . 10
9 ANNEX B (normative) Categories of environmental protection . 11
10 ANNEX T (informative) Test report . 12
11 Bibliography . 13
oSIST prEN IEC 61810-7-11:2023
IEC CDV 61810-7-11:2023 © IEC 2023 – 3 –
19 INTERNATIONAL ELECTROTECHNICAL COMMISSION
20 ____________
22 Electrical Relays –
23 Testing and Measurements
25 Part 7-11: Enclosure Protection and Degree of Protection
27 FOREWORD
28 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization
29 comprising all national electrotechnical committees (IEC National Committees). The object of IEC is to p
30 2) romote international co-operation on all questions concerning standardization in the electrical and electronic
31 fields. To this end and in addition to other activities, IEC publishes International Standards, Technical
32 Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred
33 to as "IEC Publication(s)"). Their preparation is entrusted to technical committees; any IEC National
34 Committee interested in the subject dealt with may participate in this preparatory work. International,
35 governmental and non-governmental organizations liaising with the IEC also participate in this preparation.
36 IEC collaborates closely with the International Organization for Standardization (ISO) in accordance with
37 conditions determined by agreement between the two organizations.
38 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
39 consensus of opinion on the relevant subjects since each technical committee has representation from all
40 interested IEC National Committees.
41 3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
42 Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
43 Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
44 misinterpretation by any end user.
45 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
46 transparently to the maximum extent possible in their national and regional publications. Any divergence between
47 any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter.
48 5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
49 assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
50 services carried out by independent certification bodies.
51 6) All users should ensure that they have the latest edition of this publication.
52 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
53 members of its technical committees and IEC National Committees for any personal injury, property damage or
54 other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
55 expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications.
56 8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
57 indispensable for the correct application of this publication.
58 9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent
59 rights. IEC shall not be held responsible for identifying any or all such patent rights.
60 The International Standards of the IEC 61810 have been prepared by IEC technical committee
61 94: All-or-nothing electrical relays.
62 The text of this International Standard is based on the following documents:
CD CC
94/828/CD 94/918/CC
64 Full information on the voting for the approval of this International Standard can be found in the
65 report on voting indicated in the above table.
66 This document has been drafted in accordance with the ISO/IEC Directives, Part 2.
67 A list of all parts of IEC 61810 series, published under the general title Electromechanical
68 elementary relays, can be found on the IEC website.

oSIST prEN IEC 61810-7-11:2023
– 4 – IEC CDV 61810-7-11:2023 © IEC 2023
69 This International Standard is to be used in conjunction with IEC 61810-1:2015.
70 The committee has decided that the contents of this document will remain unchanged until the
71 stability date indicated on the IEC website under "http://webstore.iec.ch" in the data related to
72 the specific document. At this date, the document will be
73 • reconfirmed,
74 • withdrawn,
75 • replaced by a revised edition, or
76 • amended.
oSIST prEN IEC 61810-7-11:2023
IEC CDV 61810-7-11:2023 © IEC 2023 – 5 –
79 Electrical Relays –
80 Tests and Measurements
82 Part 7-11: Enclosure Protection and Degree of Protection
86 1 Scope
87 This part of IEC 61810-7 is used for testing along with the appropriate severities and conditions
88 for measurements and tests designed to assess the ability of specimens to perform under
89 expected conditions of transportation, storage and all aspects of operational use.
90 The object of this test is to define standard test methods for appropriate enclosure sealing
91 testing.
92 2 Normative references
93 The following documents are referred to in the text in such a way that some or all of their content
94 constitutes requirements of this document. For dated references, only the edition cited applies.
95 For undated references, the latest edition of the referenced document (including any
96 amendments) applies.
97 IEC 60068-2-17:1994, Basic environmental testing procedures - Part 2-17: Tests - Test Q:
98 Sealing
99 IEC 60068-2-68:1994, Environmental testing - Part 2-68: Tests - Test L: Dust and sand
100 IEC 60529:1989, Degrees of protection provided by enclosures (IP Code)
101 IEC 61810-7-0:202X, Electrical relays – Tests and Measurements – Part 7-0: Testing general
102 IEC 61810-7-4:202X, Electrical relays – Tests and Measurements – Part 7-4: Dielectric strength
103 test
104 IEC 61810-7-7:202X, Electrical relays – Tests and Measurements – Part 7-7: Functional tests
105 IEC 61810-7-15:202X, Electrical relays – Tests and Measurements – Part 7-15: Robustness of
106 terminals
107 3 Terms and definitions
108 3.1
109 relay technology category
110 RT (abbreviation)
111 categories of relays, based upon environmental protection
112 Note – Six categories are in use (RT0 to RTV).
oSIST prEN IEC 61810-7-11:2023
– 6 – IEC CDV 61810-7-11:2023 © IEC 2023
114 4 Test procedure
115 4.1 Purpose
116 To determine the effectiveness of the relay enclosure in regard to either sealing or protection
117 against ingress of dust and water.
118 The relay technology categories are described in Annex B.
119 4.2 Dust protection
120 This test applies only for relay according to RTI.
121 Procedure
122 This test shall be carried out in accordance with test La2 of IEC 60068-2-68. The non-operated
123 relay shall be mounted with standard mounting position pin down if not otherwise specified in
124 the test chamber. The air pressure within the relay shall be that of the ambient air pressure in
125 the test chamber (category 2 enclosure). The relay shall be subjected to talc (hydrated
126 magnesium silicate) for 8 h. After a recovery period of 2 h under normal atmospheric conditions
127 and after cleaning (removal of external surface dust) the test samples shall be submitted to
128 visual and functional measurement.
129 Conditions to be specified
130 The conditions to be specified are the following:
131 a) pressure reduction inside the relay, if required;
132 b) position of the relay, if other than normal operating position;
133 4.3 Sealing
134 Procedure
135 A suitable soldering process in accordance with manufacturer specification shall be chosen out
136 of IEC 61810-7-15 and all test specimens shall go through the selected soldering process.
137 Procedure 1 for RTIII relays
138 The sealing test shall be made by immersion in a liquid at a temperature equal to the upper
139 limit of the operating temperature range of the relay (with a tolerance of –0 K/+5 K) in
140 accordance with test Qc, method 1 or 2 of IEC 60068-2-17. Immersion times shorter than
141 10 min may be specified by the manufacturer. Bubbles shall not exceed the limits given in
142 IEC 60068-2-17.
143 Procedure 2 for RT IV and V for relays
144 The helium detection test shall be carried out in accordance with test Qk, method 1 or 2 of
145 IEC 60068-2-17. Where procedure 2 is used and the existence of a gross leak cannot be ruled
146 out, it shall be followed by procedure 1.
147 For a detailed description of the Helium sniffer test see Annex A
148 NOTE The helium leak rate is not equal to the leak rate of the gases normally used within sealed relays.
149 If the time interval between sealing and testing has been more than 48 h, the relay shall be
150 exposed to an atmosphere of helium at high pressure.
151 The difference pressure and the duration of exposure shall be as prescribed by the
152 manufacturer.
oSIST prEN IEC 61810-7-11:2023
IEC CDV 61810-7-11:2023 © IEC 2023 – 7 –
153 After the exposure, the absorbed helium shall be cleaned from the surface as prescribed by the
154 manufacturer.
155 Procedure 3 – sealing test method Ql
156 This test applies for reed switches and high voltage vacuum reed switches as an alternative to
157 Qk test.
158 The sealing test shall be in accordance with test Ql of IEC 60068-2-17. It is applicable only to
159 specimen that are able to withstand external overpressure Annex F of IEC 60017-2-17 shall
160 be considered.
161 Procedure 4 – arc time duration test
162 This test applies for heavy duty reed switches only.
163 The test shall be performed:
164 a) Arcing time less than
165 i) 60ms for 3A types
166 ii) 100ms for 5A types
167 b) Coil voltage: 150% of must operate voltage
168 c) Load voltage: 100V DC to 110V DC
169 d) Load current: 0,5A to 0,55 A
170 e) Total number of operations: 3
171 The test setup shall be in accordance to IEC 61810-7-19 and carried out at ambient
172 environmental.
173 Conditions to be prescribed
174 The conditions to be prescribed are the following:
175 a) procedure or sequence of procedures, and methods in them;
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.