Personal eye-protection - Ultraviolet filters - Transmittance requirements and recommended use

This European Standard specifies the scale numbers and transmittance requirements for filters for protection against ultraviolet radiation. The other applicable requirements for these types of filters are given in EN 166:1995. Guidance on the selection and use of these filters are given in Annex A. NOTE: The protective filters specified in this standard are not suitable for the direct or indirect observation of an electric arc. For this purpose a welding filter appropriate to the source being observed should be used. Such a filter would not have a scale number less than 6.

Persönlicher Augenschutz - Ultraviolettschutzfilter - Transmissionsanforderungen und empfohlene Anwendung

Die vorliegende Europäische Norm legt Schutzstufen und Transmissionsanforderungen für Schutzfilter gegen Ultraviolettstrahlung fest.
Die weiteren geltenden Anforderungen für diese Filterarten und die Anforderungen für die Tragkörper/Rahmen, in die sie eingebaut werden sollen, sind in EN 166 angegeben.
Anhang B gibt einen Leitfaden für die Auswahl und Anwendung dieser Filter.
ANMERKUNG      Die in dieser Norm behandelten Schutzfilter sind nicht für das direkte Sehen in helle Lichtquellen wie Xenon-Hochdruckbogenlampen oder für die direkte oder indirekte Beobachtung eines Lichtbogens geeignet. Für diese Zwecke sollte ein Schweißerschutzfilter nach EN 169 mit einer entsprechenden Schutzstufe angewendet werden, das für die beobachtete Lichtquelle geeignet ist.

Protection individuelle de l'oeil - Filtres pour l'ultraviolet - Exigences relatives au facteur de transmission et utilisation recommandée

La présente Norme européenne spécifie les numéros d'échelon et les exigences relatives au facteur de transmission des filtres de protection contre le rayonnement ultraviolet.
Les autres exigences applicables pour ces types de filtres et les montures/supports sur lesquels ils doivent etre montés figurent dans l'EN 166.
Un guide pour le choix et l'utilisation de ces filtres est donné a l'annexe B.
NOTE   Les filtres de protection spécifiés dans la présente norme ne conviennent pas pour l'observation directe de sources lumineuses vives telles que les lampes a arc de xénon a haute pression ou pour l'observation directe ou indirecte d'un arc de soudage électrique. Dans ce cas, il convient d'utiliser un filtre de soudage tel que spécifié dans l'EN 169, ayant un numéro d'échelon approprié a la source observée.

Osebno varovanje oči - Ultravijolični filtri - Zahteve za prepustnost in priporočena uporaba

General Information

Status
Withdrawn
Publication Date
31-Dec-2002
Withdrawal Date
21-Aug-2022
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
20-May-2022
Due Date
12-Jun-2022
Completion Date
22-Aug-2022

Relations

Buy Standard

Standard
EN 170:2003
English language
13 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Personal eye-protection - Ultraviolet filters - Transmittance requirements and recommended useXSRUDEDProtection individuelle de l'oeil - Filtres pour l'ultraviolet - Exigences relatives au facteur de transmission et utilisation recommandéePersönlicher Augenschutz - Ultraviolettschutzfilter - Transmissionsanforderungen und empfohlene Anwendung13.340.20Varovalna oprema za glavoHead protective equipmentICS:SIST EN 170:2003enTa slovenski standard je istoveten z:EN 170:200201-januar-2003SIST EN 170:2003SLOVENSKI
STANDARDSIST EN 170:19961DGRPHãþD







EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 170October 2002ICS 13.340.20Supersedes EN 170:1992English versionPersonal eye-protection - Ultraviolet filters - Transmittancerequirements and recommended useProtection individuelle de l'oeil - Filtres pour l'ultraviolet -Exigences relatives au facteur de transmission et utilisationrecommandéePersönlicher Augenschutz - Ultraviolettschutzfilter -Transmissionsanforderungen und empfohlene AnwendungThis European Standard was approved by CEN on 12 September 2002.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Management Centre has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece,Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2002 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 170:2002 E



EN 170:2002 (E)2ContentspageForeword.31Scope.42Normative references.43Terms and definitions.44Designation and identification.45Requirements.45.1General.45.2Transmittance requirements.45.3Ocular with enhanced colour recognition (optional).5Annex A (normative)
Relative visual attenuation quotient for signal light recognition.6Annex B (informative)
Guidance on selection and use.8Annex C (informative)
Uncertainty of measurement and results interpretation.10Annex ZA (informative)
Clauses of this European Standard addressing essential requirements or otherprovisions of EU Directives.12Bibliography.13



EN 170:2002 (E)3ForewordThis document (EN 170:2002) has been prepared by Technical Committee CEN /TC 85, "Eye-protectiveequipment", the secretariat of which is held by AFNOR.This European Standard shall be given the status of a national standard, either by publication of an identical text orby endorsement, at the latest by April 2003, and conflicting national standards shall be withdrawn at the latest byApril 2003.This document supersedes EN 170:1992.This document has been prepared under a mandate given to CEN by the European Commission and the EuropeanFree Trade Association, and supports essential requirements of EU Directive(s).For relationship with EU Directive(s), see informative annex ZA, which is an integral part of this document.In this European Standard, Annex A is normative and Annexes B and C are informative.According to the CEN/CENELEC Internal Regulations, the national standards organizations of the followingcountries are bound to implement this European Standard: Austria, Belgium, Czech Republic, Denmark, Finland,France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Spain,Sweden, Switzerland and the United Kingdom.



EN 170:2002 (E)41 ScopeThis European Standard specifies the scale numbers and transmittance requirements for filters for protectionagainst ultraviolet radiation.The other applicable requirements for these types of filters and the frames/mountings to which they are intended tobe fitted are given in EN 166.Guidance on the selection and use of these filters are given in annex B.NOTEThe protective filters specified in this standard are not suitable for the direct viewing of bright light sources likeXenon high-pressure arc lamps or for the direct or indirect observation of an electric welding arc. For this purpose a weldingfilter as specified in EN 169 and with a scale number appropriate to the source being observed should by used.2 Normative referencesThis European Standard incorporates by dated or undated reference, provisions from other publications. Thesenormative references are cited at the appropriate places in the text and the publications are listed hereafter. Fordated references, subsequent amendments to or revisions of any of these publications apply to this EuropeanStandard only when incorporated in it by amendment or revision. For undated references the latest edition of thepublication referred to applies (including amendments).EN 165:1995, Personal eye-protection – Vocabulary.EN 166, Personal eye-protection – Specifications.EN 167, Personal eye-protection – Optical test methods.ISO/CIE 10526:1999, CIE Standard illuminants for colorimetry.ISO/CIE 10527:1991, CIE Standard colorimetric observers.3 Terms and definitionsFor the purposes of this European Standard, the terms and definitions given in EN 165:1995 apply.4 Designation and identificationThe complete table of numbering of filters is given in EN 166.The marking of oculars and frame is described in EN 166.The scale number of ultraviolet filters comprises the code number 2 and the shade number corresponding to thefilter, from 1,2 to 5 (see Table 1).5 Requirements5.1 GeneralThe requirements of EN 166 apply to ultraviolet filters. Only those requirements that are different from orsupplement the EN 166 specifications are given in this European standard.5.2 Transmittance requirementsThe definitions of transmittances are given in EN 165.



EN 170:2002 (E)5The determination of luminous transmittance is described in EN 167.The transmittance requirements for filters used for protection against ultraviolet radiation are given in Table 1.Table 1 – Transmittance requirementsMaximum spectraltransmittance in theultraviolet t(l)Luminous transmittancetvTransmittance in theinfrared spectral rangeScalenumber313 nm%365 nm%maximum%minimum%2-1,20,00031010074,42-1,40,0003974,458,12-1,70,0003758,143,22-20,0003543,229,1no specification2-2,50,0003329,117,82-30,0003217,88,52-40,00030,88,53,22-50,00030,33,21,2Minimum and maximum values of luminous transmittance may be exceeded by taking into account the limits ofrelative uncertainty given in EN 167.Additional requirements:a) for 210 nm £ l £ 313 nm the spectral transmittance shall not exceed the value specified for 313 nm;b) for 313 nm < l £ 365 nm the spectral transmittance shall not exceed the value specified for 365 nm;c) for 365 nm < l £ 405 nm the spectral transmittance shall not exceed the
...