(Main)Fibre cement flat sheets - Product specification and test methods
Fibre cement flat sheets - Product specification and test methods
This document specifies the technical requirements and establishes methods of inspection and test as well as acceptance conditions for fibre-cement flat sheets, siding shingles and planks (referred to as sheets later in this document) for one or more of the following uses: - internal wall and ceiling finishes, - external wall and ceiling finishes. Products covered by this document can be used for other purposes provided they comply with the relevant application standard, e.g. rigid underlays. This document covers sheets reinforced with fibres of different types as specified in 5.1.1. This document does not cover sheets for fire protection purposes. This document does not include calculations with regard to works, design requirements, installation techniques, wind uplift or rain proofing of the installed sheets.
Faserzement-Tafeln - Produktspezifikation und Prüfverfahren
Die folgende normative Verweisung ist hinzuzufügen:
"EN 13823, Prüfungen zum Brandverhalten von Bauprodukten - Thermische Beanspruchung durch einen einzelnen brennenden Gegenstand für Bauprodukte mit Ausnahme von Bodenbelägen."
Plaques planes en fibres-ciment - Spécifications du produit et méthodes d'essai
Vlaknato-cementne ravne plošče - Specifikacija za izdelek in preskusne metode
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 12467:2005/A2:2006
01-december-2006
9ODNQDWRFHPHQWQHUDYQHSORãþH6SHFLILNDFLMD]DL]GHOHNLQSUHVNXVQHPHWRGH
Fibre cement flat sheets - Product specification and test methods
Faserzement-Tafeln - Produktspezifikation und Prüfverfahren
Plaques planes en fibres-ciment - Spécifications du produit et méthodes d'essai
Ta slovenski standard je istoveten z: EN 12467:2004/A2:2006
ICS:
91.100.40 &HPHQWQLL]GHONLRMDþDQL] Products in fibre-reinforced
YODNQL cement
SIST EN 12467:2005/A2:2006 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
EUROPEAN STANDARD
EN 12467:2004/A2
NORME EUROPÉENNE
EUROPÄISCHE NORM
September 2006
ICS 91.100.40
English Version
Fibre cement flat sheets - Product specification and test
methods
Plaques planes en fibres-ciment - Spécifications du produit Faserzement-Tafeln - Produktspezifikation und
et méthodes d'essai Prüfverfahren
This amendment A2 modifies the European Standard EN 12467:2004; it was approved by CEN on 14 August 2006.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for inclusion of this
amendment into the relevant national standard without any alteration. Up-to-date lists and bibliographical references concerning such
national standards may be obtained on application to the Central Secretariat or to any CEN member.
This amendment exists in three official versions (English, French, German). A version in any other language made by translation under the
responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,
Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania,
Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: rue de Stassart, 36 B-1050 Brussels
© 2006 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 12467:2004/A2:2006: E
worldwide for CEN national Members.
---------------------- Page: 2 ----------------------
EN 12467:2004/A2:2006 (E)
Contents Page
Foreword.3
1 Modification to Clause 2 .4
2 Modifications to 7.5.2 .4
2.1 Modification 1.4
2.2 Modification 2.4
2
---------------------- Page: 3 ----------------------
EN 12467:2004/A2:2006 (E)
Foreword
This document (EN 12467:2004/A2:2006) has been prepared by Technical Committee CEN/TC 128 “Roof
covering products for discontinuous laying and products for wall cladding”, the secretariat of which is held by
IBN/BIN.
This European Standard shall be given the status of a national standard, either by publication of an identical
text or by endorsement, at the latest by March 2007, and conflicting national standards shall be withdrawn at
the latest by June 2008.
This document has been prepared under a mandate given to CEN by the European Commission and the
European Free Trade Association, and supports essential requirements of EU Directive(s).
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following
countries are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden,
Switzerland and United Kingdom.
3
---------------------- Page: 4 ----------------------
EN 12467:2004/A2:2006 (E)
1 Modification to Clause 2
Add the following normative references:
“EN 13823, Reaction to fire tests for building products — Building products excluding floorings exposed to the
thermal attack by a single burning item
EN ISO 1716, Reaction to fire tests for building products — Determination of the heat of combustion (ISO
1716:2002)”
and delete the full stops at the end of the reference titles.
2 Modifications to 7.5.2
2.1 Modification 1
Add the following subtitle:
“7.5.2.1 General”
2.2 Modification 2
Add the following paragraphs:
“7.5.2.2 Mounting and fixing provisions for EN 13823
7.5.2.2.1 End use applications
The end uses covered by the standardised mounting and fixing are fibre cement flat sheets used as external
and internal wall and ceiling finishes. In these end uses, flat sheets are fixed to a wooden or metal
substructure with mechanical devices. The side of the flat sheets directed away from the fire is in contact with
a ventilated cavity which is closed by either a rigid substructure or a structural wall or ceiling construction. The
cavity may or may not be partially filled with thermal insulation.
7.5.2.2.2 Test specimen
Products used for the construction of the test assembly are fibre cement flat sheets with standard dimensions
of length, width and thickness. They are cut to size to accommodate the dimensions of the test assembly.
They include all facings and/or coatings that are normally applied to the product as it is placed on the market.
7.5.2.2.3 Test assembly
7.5.2.2.3.1 Dimensions
The test assembly is a corner set up made of two timber frame supporting constructions each with a height of
1,5 m to which the fibre cement flat sheets are fixed. One frame forms a long wing (1,0 m) the other frame
forms a short wing (0,5 m). Further information is given in Figures 6, 7, 8, 9 and 10.
4
----------------------
...
SLOVENSKI SIST EN
12467:2005/oprA2:2005
PREDSTANDARD
maj 2005
Vlaknato-cementne ravne plošče - Specifikacija za izdelek in preskusne
metode
Fibre cement flat sheets - Product specification and test methods
ICS 91.100.40 Referenčna številka
SIST EN 12467:2005/oprA2:2005(en)
© Standard je založil in izdal Slovenski inštitut za standardizacijo. Razmnoževanje ali kopiranje celote ali delov tega dokumenta ni dovoljeno
---------------------- Page: 1 ----------------------
EUROPEAN STANDARD
DRAFT
EN 12467:2004
NORME EUROPÉENNE
EUROPÄISCHE NORM
prA2
March 2005
ICS
English version
Fibre cement flat sheets - Product specification and test
methods
Plaques planes en fibres-ciment - Spécifications du produit Faserzement-Tafeln - Produktspezifikation und
et méthodes d'essai Prüfverfahren
This draft amendment is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee CEN/TC 128.
This draft amendment A2, if approved, will modify the European Standard EN 12467:2004. If this draft becomes an amendment, CEN
members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for inclusion of this amendment
into the relevant national standard without any alteration.
This draft amendment was established by CEN in three official versions (English, French, German). A version in any other language made
by translation under the responsibility of a CEN member into its own language and notified to the Management Centre has the same status
as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,
Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia,
Slovenia, Spain, Sweden, Switzerland and United Kingdom.
Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without notice and
shall not be referred to as a European Standard.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: rue de Stassart, 36 B-1050 Brussels
© 2005 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 12467:2004/prA2:2005: E
worldwide for CEN national Members.
---------------------- Page: 2 ----------------------
EN 12467:2004/prA2:2005 (E)
Contents Page
Foreword.3
1 Modification to clause 2 .4
2 Modifications to 7.5.2 .4
2
---------------------- Page: 3 ----------------------
EN 12467:2004/prA2:2005 (E)
Foreword
This document (EN 12467:2004/prA2:2005) has been prepared by Technical Committee CEN/TC 128 “Roof
covering products for discontinuous laying and products for wall cladding”, the secretariat of which is held by
IBN.
This document is currently submitted to the CEN Enquiry.
This document has been prepared under a mandate given to CEN by the European Commission and the
European Free Trade Association, and supports essential requirements of EU Directive(s).
3
---------------------- Page: 4 ----------------------
EN 12467:2004/prA2:2005 (E)
1 Modification to clause 2
Add the following normative references:
“EN 13823, Reaction to fire tests for building products – Building products excluding floorings exposed to the
thermal attack by a single burning item.”
2 Modifications to 7.5.2
2.1 Modification 1
Add the following subtitle:
“7.5.2.1 General”
2.2 Modification 2
Add the following paragraphs:
“7.5.2.2 Mounting and fixing provisions for EN 13823
7.5.2.2.1 End use applications
The end uses covered by the standardised mounting and fixing are fibre cement flat sheets used as external
and internal wall and ceiling finishes. In these end uses, flat sheets are fixed to a wooden or metal
substructure with mechanical devices. The side of the flat sheets directed away from the fire is in contact with
a ventilated cavity which is closed by either a rigid substructure or a structural wall or ceiling construction. The
cavity may or may not be partially filled with thermal insulation.
End uses where fibre cement flat sheets are fixed directly to a wall or ceiling construction without a cavity
behind or fixed by other than mechanical devices (e.g. glued) are not covered.
7.5.2.2.2 Test specimen
Products used for the construction of the test assembly are fibre cement flat sheets with standard dimensions
of length, width and thickness. They are cut to size to accommodate the dimensions of the test assembly.
They include all facings and/or coatings that are normally applied to the product as it is placed on the market.
7.5.2.2.3 Test assembly
7.5.2.2.3.1 Dimensions
The test assembly is a corner set up made of two timber frame supporting constructions each with a height of
1,5 m. One frame forms a long wing (1,0 m) the other frame forms a short wing (0,5 m). Further information is
given in Figures 6,7,8,9 and 10.