General Information

Abstract

Status
Not Published
Public Enquiry End Date
25-Dec-2025
Technical Committee
MOC - Mobile Communications
Current Stage
5020 - Formal vote (FV) (Adopted Project)
Start Date
22-Sep-2026
Due Date
10-Nov-2026

Buy Documents

Draft

oSIST prEN IEC 60794-1-205:2024 - BARVE

English language (12 pages)
Preview
Preview
e-Library read for
1 day
Draft

oSIST prEN IEC 60794-1-205:2025

English language (13 pages)
Preview
Preview
e-Library read for
1 day

Overview

kSIST FprEN IEC 60794-1-205:2026 is a Slovenian adoption of the international standard for optical fibre cables titled "Optical fibre cables - Part 1-205: Generic specification - Basic optical cable test procedures - Environmental test methods - Water penetration, method F5." Developed by the International Electrotechnical Commission (IEC) and adopted by SIST, this standard specifies uniform test procedures for determining the ability of optical fibre cables to resist water penetration under environmental exposure. It directly addresses the reliability and longevity of fibre optic cable installations by detailing water penetration testing methods and conditions, supporting high performance in critical communication infrastructure.

Key Topics

  • Water Penetration Testing: Establishes procedures (F5A, F5B, F5C) to assess the effectiveness of water blocking in optical fibre cables.
    • F5A: Evaluates water penetration due to sheath damage along the outer core and sheath interface.
    • F5B: Tests longitudinal water penetration along the cable’s cross-section, simulating exposure at a cut or termination.
    • F5C: Applies to cables with swellable water-blocking materials and includes pre-soak or controlled flow setups to simulate gradual exposure.
  • Sample Preparation: Describes sample sizes (typically up to 3m, with options for longer samples) and requirements for removing cable layers to properly test water ingress.
  • Testing Apparatus and Conditions: Outlines the necessary fixtures, use of potable or deionized water, the option to include dyes for inspection, and conditions like 1 meter water head and specific test durations.
  • Reporting and Specification: Emphasizes the need for detailed reporting, specifying method used, atmospheric test conditions, number of samples, water and dye details, and any deviations from standard apparatus or procedures.

Applications

Water penetration testing is critical for a range of optical fibre cable applications where environmental resilience is crucial. Typical uses include:

  • Underground Fibre Optic Networks: Ensures durability and protection against groundwater infiltration, preventing service outages in telecom networks.
  • Aerial and Duct Installations: Assures performance over time where cables are exposed to rain, condensation, or accidental sheath damage.
  • Industrial and Outdoor Installations: Validates cables used in challenging environments such as OPGW (Optical Ground Wire) or OPAC (Optical Attached Cable), supporting utilities and infrastructure projects.
  • Quality Assurance in Manufacturing: Enables cable makers and system installers to demonstrate compliance with international standardization, ensuring product reliability before deployment.
  • Maintenance and Inspection: Supports testing protocols during cable assessment or after repairs to certify ongoing water resistance.

Related Standards

The kSIST FprEN IEC 60794-1-205:2026 standard is part of the comprehensive IEC 60794 series, addressing optical fibre cable specification and testing. Closely related standards include:

  • IEC 60794-1-1: General specification for optical fibre cables, providing broad requirements.
  • IEC 60794-1-2: Offers guidance for basic optical cable test procedures.
  • IEC 60794-1-22:2017 (superseded): The previous method F5 for water penetration, now replaced and split into individual documents for improved clarity and maintenance.

Practical Value

Implementing this standard provides substantial benefits:

  • Enhanced reliability of fibre optic networks by preventing water-induced failures
  • Streamlined procurement and acceptance testing with globally recognized procedures
  • Improved performance documentation for cable manufacturers and installers
  • Standardization of testing across diverse environmental conditions, supporting international market access and regulatory compliance

By adhering to kSIST FprEN IEC 60794-1-205:2026, stakeholders ensure robust, high-quality optical fibre cable installations resistant to water penetration, supporting the integrity and durability of modern communication infrastructure.

Relations

Effective Date
08-Oct-2025

Buy Documents

Draft

oSIST prEN IEC 60794-1-205:2024 - BARVE

English language (12 pages)
Preview
Preview
e-Library read for
1 day
Draft

oSIST prEN IEC 60794-1-205:2025

English language (13 pages)
Preview
Preview
e-Library read for
1 day

Get Certified

Connect with accredited certification bodies for this standard

ANCE

Mexican certification and testing association.

EMA Mexico Verified

Intertek Slovenia

Intertek testing, inspection, and certification services in Slovenia.

UKAS Slovenia Verified

LNE (Laboratoire National de Métrologie et d'Essais)

French national laboratory for metrology and testing.

COFRAC France Verified

Sponsored listings

Frequently Asked Questions

kSIST FprEN IEC 60794-1-205:2026 is a draft published by the Slovenian Institute for Standardization (SIST). Its full title is "Optical fibre cables - Part 1-205: Generic specification - Basic optical cable test procedures - Environmental test methods - Water penetration, method F5". This standard covers: Optical fibre cables - Part 1-205: Generic specification - Basic optical cable test procedures - Environmental test methods - Water penetration, method F5

Optical fibre cables - Part 1-205: Generic specification - Basic optical cable test procedures - Environmental test methods - Water penetration, method F5

kSIST FprEN IEC 60794-1-205:2026 is classified under the following ICS (International Classification for Standards) categories: 33.180.10 - Fibres and cables. The ICS classification helps identify the subject area and facilitates finding related standards.

kSIST FprEN IEC 60794-1-205:2026 has the following relationships with other standards: It is inter standard links to SIST EN IEC 60794-1-22:2018. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

kSIST FprEN IEC 60794-1-205:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


SLOVENSKI STANDARD
oSIST prEN IEC 60794-1-205:2024
01-julij-2024
Optični kabli - 1-205. del: Splošna specifikacija - Osnovni preskusni postopki za
optične kable - Okoljske preskusne metode - Vdor vode, metoda F5
Optical fibre cables - Part 1-205: Generic specification - Basic optical cable test
procedures - Environmental test methods - Water penetration, method F5
Ta slovenski standard je istoveten z: prEN IEC 60794-1-205:2024
ICS:
33.180.10 (Optična) vlakna in kabli Fibres and cables
oSIST prEN IEC 60794-1-205:2024 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

oSIST prEN IEC 60794-1-205:2024

oSIST prEN IEC 60794-1-205:2024

86A/2453/CDV
COMMITTEE DRAFT FOR VOTE (CDV)
PROJECT NUMBER:
IEC 60794-1-205 ED1
DATE OF CIRCULATION: CLOSING DATE FOR VOTING:
2024-05-31 2024-08-23
SUPERSEDES DOCUMENTS:
86A/2348/CD, 86A/2389A/CC
IEC SC 86A : FIBRES AND CABLES
SECRETARIAT: SECRETARY:
France Mr Laurent Gasca
OF INTEREST TO THE FOLLOWING COMMITTEES: PROPOSED HORIZONTAL STANDARD:

Other TC/SCs are requested to indicate their interest, if any, in
this CDV to the secretary.
FUNCTIONS CONCERNED:
EMC ENVIRONMENT QUALITY ASSURANCE SAFETY
SUBMITTED FOR CENELEC PARALLEL VOTING NOT SUBMITTED FOR CENELEC PARALLEL VOTING
Attention IEC-CENELEC parallel voting
The attention of IEC National Committees, members of CENELEC,
is drawn to the fact that this Committee Draft for Vote (CDV) is
submitted for parallel voting.
The CENELEC members are invited to vote through the CENELEC
online voting system.
This document is still under study and subject to change. It should not be used for reference purposes.
Recipients of this document are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.
Recipients of this document are invited to submit, with their comments, notification of any relevant “In Some Countries” clau ses to be
included should this proposal proceed. Recipients are reminded that the CDV stage is the final stage for submitting ISC c lauses.
(SEE AC/22/2007 OR NEW GUIDANCE DOC).

TITLE:
Optical fibre cables - Part 1-205: Generic specification - Basic optical cable test procedures - Environmental
test methods – Water penetration, Method F5

PROPOSED STABILITY DATE: 2028
NOTE FROM TC/SC OFFICERS:
file, to make a copy and to print out the content for the sole purpose of preparing National Committee positions. You may not copy
or "mirror" the file or printed version of the document, or any part of it, for any other purpose without permission in writi ng from IEC.

oSIST prEN IEC 60794-1-205:2024
86A/2453/CDV – 2 – IEC CDV 60794-1-205 © IEC 2024
CONTENTS
CONTENTS . 2
FOREWORD . 3
INTRODUCTION . 5
1 Scope . 6
2 Normative references . 6
3 Terms and definitions . 6
4 Method F5 – Water penetration . 6
4.1 Object . 6
4.2 Sample . 7
4.2.1 Method F5A . 7
4.2.2 Method F5B . 7
4.2.3 Method F5C (for cables with swellable water blocking material) . 7
4.3 Apparatus . 7
4.3.1 Test fixtures and set-up . 7
4.3.2 Water . 8
4.3.2 Orifice (method F5C) . 8
4.4 Procedure . 8
4.4.1 Method F5A and F5B . 8
4.4.2 Method F5C . 8
4.4.2.1 Pre-soak (alternative) . 8
4.4.2.2 Orifice (alternative) . 8
4.4.2.3 Longer sample (alternative) . 8
4.5 Requirements . 8
4.6 Details to be specified . 9
4.7 Details to be reported . 9
Bibliography . 12

Figure 1 – Test arrangement for method F5A . 9
Figure 2 – Test arrangement for method F5B . 9
Figure 3 – Test arrangement for method F5C: pre-soaked sample . 10
Figure 4 – Test arrangement for method F5C: pre-soak procedure . 10
Figure 5 – Test arrangement for method F5C: orifice . 11
Figure 6 – Test arrangement for method F5C: longer sample . 11

oSIST prEN IEC 60794-1-205:2024
IEC CDV 60794-1-205 © IEC 2024 – 3 – 86A/2453/CDV

2 INTERNATIONAL ELECTROTECHNICAL COMMISSION
3 ____________
5 OPTICAL FIBRE CABLES –
7 Part 1-205: Generic specification –
8 Basic optical cable test procedures –
9 Environmental test methods – Water penetration, Method F5
11 FOREWORD
12 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
13 all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international
14 co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and
15 in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports,
16 Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their
17 preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with
18 may participate in this preparatory work. International, governmental and non-governmental organizations liaising
19 with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for
20 Standardization (ISO) in accordance with conditions determined by agreement between the two organizations.
21 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
22 consensus of opinion on the relevant subjects since each technical committee has representation from all
23 interested IEC National Committees.
24 3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
25 Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
26 Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
27 misinterpretation by any end user.
28 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
29 transparently to the maximum extent possible in their national and regional publications. Any divergence between
30 any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter.
31 5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
32 assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
33 services carried out by independent certification bodies.
34 6) All users should ensure that they have the latest edition of this publication.
35 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
36 members of its technical committees and IEC National Committees for any personal injury, property damage or
37 other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
38 expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications.
39 8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
40 indispensable for the correct application of this publication.
41 9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent
42 rights. IEC shall not be held responsible for identifying any or all such patent rights.
43 International Standard IEC 60794-1-205 has been prepared by subcommittee 86A: Fibres and
44 cables, of IEC technical committee 86: Fibre optics.
45 This first edition of IEC 60794-1-205 cancels and replaces methods F5 of the second edition of
46 IEC 60794-1-22 published in 2017.
47 This edition includes the following significant technical changes with respect to the previous
48 edition:
49 a) the environmental test contained in IEC 60794-1-22: 2017 will now be individually numbered
50 in the IEC 60794-1-2xx series. Each test method is now considered to be an individual
51 document rather than part of a multi-test method compendium. Full cross-reference details
52 are given in IEC 60794-1-2.

oSIST prEN IEC 60794-1-205:2024
86A/2453/CDV – 4 – IEC CDV 60794-1-205 © IEC 2024
53 b) The clauses of “4.6 Details to be specified” and “4.7 Details to be reported” were revised.
54 The text of this International Standard is based on the following documents:
FDIS Report on voting
86A/xxxx/FDIS 86A/xxxx/RVD
56 Full information on the voting for the approval of this International Standard can be found in the
57 report on voting indicated in the above table.
58 The language used for the development of this International Standard is English.
59 This document has been drafted in accordance with the ISO/IEC Directives, Part 2 , and
60 developed in accordance with ISO/IEC Directives, Part 1 and ISO/IEC Directives, IEC Supplement,
61 avail
...


SLOVENSKI STANDARD
oSIST prEN IEC 60794-1-205:2025
01-december-2025
Optični kabli - 1-205. del: Splošna specifikacija - Osnovni preskusni postopki za
optične kable - Okoljske preskusne metode - Vdor vode, metoda F5
Optical fibre cables - Part 1-205: Generic specification - Basic optical cable test
procedures - Environmental test methods - Water penetration, method F5
Lichtwellenleiterkabel – Teil 1-205: Fachgrundspezifikation – Grundlegende
Prüfverfahren für Lichtwellenleiterkabel - Umweltprüfverfahren -Wasserdurchdringung,
Methode F5
Câbles à fibres optiques - Partie 1-205: Spécification générique - Procédures
fondamentales d’essais des câbles optiques - Méthodes d’essais d’environnement -
Pénétration d’eau, méthode f5
Ta slovenski standard je istoveten z: prEN IEC 60794-1-205:2025
ICS:
33.180.10 (Optična) vlakna in kabli Fibres and cables
oSIST prEN IEC 60794-1-205:2025 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

oSIST prEN IEC 60794-1-205:2025

oSIST prEN IEC 60794-1-205:2025

86A/2623/CDV
COMMITTEE DRAFT FOR VOTE (CDV)
PROJECT NUMBER:
IEC 60794-1-205 ED1
DATE OF CIRCULATION: CLOSING DATE FOR VOTING:
2025-10-31 2025-12-26
SUPERSEDES DOCUMENTS:
86A/2453/CDV, 86A/2551/RVC
IEC SC 86A : FIBRES AND CABLES
SECRETARIAT: SECRETARY:
France Mr Laurent Gasca
OF INTEREST TO THE FOLLOWING COMMITTEES: HORIZONTAL FUNCTION(S):

ASPECTS CONCERNED:
SUBMITTED FOR CENELEC PARALLEL VOTING NOT SUBMITTED FOR CENELEC PARALLEL VOTING
Attention IEC-CENELEC parallel voting
The attention of IEC National Committees, members of
CENELEC, is drawn to the fact that this Committee Draft
for Vote (CDV) is submitted for parallel voting.
The CENELEC members are invited to vote through the
CENELEC online voting system.
This document is still under study and subject to change. It should not be used for reference purposes.
Recipients of this document are invited to submit, with their comments, notification of any relevant patent rights of
which they are aware and to provide supporting documentation.
Recipients of this document are invited to submit, with their comments, notification of any relevant “In Some
Countries” clauses to be included should this proposal proceed. Recipients are reminded that the CDV stage is the
final stage for submitting ISC clauses. (SEE AC/22/2007 OR NEW GUIDANCE DOC).

TITLE:
Optical fibre cables - Part 1-205: Generic specification - Basic optical cable test procedures -
Environmental test methods – Water penetration, Method F5

PROPOSED STABILITY DATE: 2029
NOTE FROM TC/SC OFFICERS:
electronic file, to make a copy and to print out the content for the sole purpose of preparing National Committee positions.
You may not copy or "mirror" the file or printed version of the document, or any part of it, for any other purpose without
permission in writing from IEC.

oSIST prEN IEC 60794-1-205:2025
IEC CDV 60794-1-205 © IEC 2025
1 CONTENTS
2 FOREWORD . 2
3 INTRODUCTION . 4
4 1 Scope . 5
5 2 Normative references . 5
6 3 Terms, definitions and abbreviated terms . 5
7 3.1 Terms and definitions . 5
8 3.2 Abbreviated terms . 5
9 4 Method F5 – Water penetration . 5
10 4.1 Object . 5
11 4.2 Sample . 6
12 4.2.1 Method F5A . 6
13 4.2.2 Method F5B . 6
14 4.2.3 Method F5C (for cables with swellable water blocking material) . 6
15 4.3 Apparatus . 6
16 4.3.1 Test fixtures and set-up . 6
17 4.3.2 Water . 7
18 4.3.3 Orifice (method F5C) . 7
19 4.4 Procedure . 7
20 4.4.1 Method F5A and Method F5B . 7
21 4.4.2 Method F5C . 7
22 4.5 Requirements . 7
23 4.6 Details to be specified . 8
24 4.7 Details to be reported . 8
25 Bibliography . 12
27 Figure 1 – Test arrangement for method F5A . 9
28 Figure 2 – Test arrangement for method F5B . 10
29 Figure 3 – Test arrangement for method F5C: pre-soaked sample . 10
30 Figure 4 – Test arrangement for method F5C: pre-soak procedure . 11
31 Figure 5 – Test arrangement for method F5C: orifice . 11
32 Figure 6 – Test arrangement for method F5C: longer sample . 12
oSIST prEN IEC 60794-1-205:2025
IEC CDV 60794-1-205 © IEC 2025
35 INTERNATIONAL ELECTROTECHNICAL COMMISSION
36 ____________
38 OPTICAL FIBRE CABLES –
40 Part 1-205: Generic specification –
41 Basic optical cable test procedures –
42 Environmental test methods – Water penetration, Method F5
44 FOREWORD
45 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
46 all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international
47 co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and
48 in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports,
49 Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their
50 preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with
51 may participate in this preparatory work. International, governmental and non-governmental organizations liaising
52 with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for
53 Standardization (ISO) in accordance with conditions determined by agreement between the two organizations.
54 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
55 consensus of opinion on the relevant subjects since each technical committee has representation from all
56 interested IEC National Committees.
57 3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
58 Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
59 Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
60 misinterpretation by any end user.
61 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
62 transparently to the maximum extent possible in their national and regional publications. Any divergence between
63 any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter.
64 5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
65 assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
66 services carried out by independent certification bodies.
67 6) All users should ensure that they have the latest edition of this publication.
68 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
69 members of its technical committees and IEC National Committees for any personal injury, property damage or
70 other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
71 expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
72 Publications.
73 8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
74 indispensable for the correct application of this publication.
75 9) IEC draws attention to the possibility that the implementation of this document may involve the use of (a)
76 patent(s). IEC takes no position concerning the evidence, validity or applicability of any claimed patent rights in
77 respect thereof. As of the date of publication of this document, IEC had not received notice of (a) patent(s), which
78 may be required to implement this document. However, implementers are cautioned that this may not represent
79 the latest information, which may be obtained from the patent database available at https://patents.iec.ch. IEC
80 shall not be held responsible for identifying any or all such patent rights.
81 IEC 60794-1-205 has been prepared by subcommittee 86A: Fibres and cables, of IEC technical
82 committee 86: Fibre optics. It is an International Standard.
83 This document partially replaces IEC 60794-1-22:2017. This edition constitutes a technical
84 revision.
85 This edition includes the following significant technical changes with respect to IEC 60794-1-
86 22:2017:
87 a) Revision of the contents of 4.6 Details to be specified and 4.7 Details to be reported in
88 comparison to IEC 60794-1-22: 2017, 5.6 and 5.7.
oSIST prEN IEC 60794-1-205:2025
IEC CDV 60794-1-205 © IEC 2025
89 The text of this International Standard is based on the following documents:
Draft Report on voting
86A/XX/FDIS 86A/XX/RVD
91 Full information on the voting for its approval can be found in the report on voting indicated in
92 the above table.
93 The language used for the development of this International Standard is English.
94 This document was drafted in accordance with ISO/IEC Directives, Part 2, and developed in
95 accordance with ISO/IEC
...