Abstract

This document establishes general principles for the execution of soil treatment by deep vibration.
The following types of treatment are covered by this document:
-   deep vibratory compaction to densify the ground as mentioned in EN 1997 3:2025, Annex I, Table I.1;
-   vibrated columns formed by inserted granular material laterally/radially compacted against the surrounding ground to form a stiff composite column-soil structure (vibrated compacted granular columns) as mentioned in EN 1997 3:2025, Annex I, Table I.2;
-   vibrated columns formed by inserted material developing unconfined compressive strength comprising a composite of binder and granular material (rigid columns) as mentioned in EN 1997 3:2025, Annex I, Table I.2.
The following treatment methods are covered by this document:
-   methods in which depth vibrators, containing oscillating weights which cause horizontal vibrations, are inserted into the ground;
-   methods in which compaction probes are inserted into the ground using a vibrator, which remains above ground surface, and which oscillates in a vertical mode.
Treatment methods are outlined in Annexes A, B, C and D.
The following treatment methods, among others, are not included in this document:
-   dynamic compaction, dynamic replacement and other methods in which some form of treatment is applied to the ground surface;
-   uncompacted granular columns primarily used as drains;
-   explosive compaction.

Status
Not Published
Public Enquiry End Date
15-Nov-2026
Technical Committee
KON - Structures
Current Stage
4020 - Public enquire (PE) (Adopted Project)
Start Date
05-Oct-2026
Due Date
22-Feb-2027

Buy Documents

Draft

oSIST prEN 14731:2026 - BARVE

English language (45 pages)
Preview
Preview
e-Library read for
×1 day

oSIST prEN 14731:2026 is the draft European Standard from CEN on execution of special geotechnical works by deep vibration. It specifies general principles for treating soil by deep vibration for deep vibratory compaction, vibrated compacted granular columns, and rigid columns, so designers, contractors and supervisors know what ground conditions, materials, methods and records the work needs.

What does oSIST prEN 14731:2026 specify?

oSIST prEN 14731:2026 covers the execution of soil treatment by deep vibration and sets out how the work is to be planned, carried out, supervised, tested and recorded. It is aimed at practical ground improvement work where the treatment is used to increase density, stiffness, bearing capacity or similar ground properties.

The document covers:

  • deep vibratory compaction
  • vibrated compacted granular columns
  • rigid columns installed with deep vibration technology

It covers work using depth vibrators with oscillating weights that produce horizontal vibration, and work using compaction probes driven by a vibrator that remains above ground and works in a vertical mode. The treatment methods are outlined in Annexes A, B, C and D.

It excludes surface-based methods such as dynamic compaction and dynamic replacement, uncompacted granular columns used mainly as drains, and explosive compaction.

AnnexWhat it covers
Annex AGeneral methods of ground treatment by deep vibration and tool types
Annex BDeep vibratory compaction, including compactability assessment and spacing of treatment points
Annex CInstallation of vibrated, compacted granular columns, including top-feed and bottom-feed processes
Annex DInstallation of vibrated rigid columns for semi-dry and pumped mixtures
Annex EExample daily report for deep vibratory works

What are the key requirements of oSIST prEN 14731:2026?

oSIST prEN 14731:2026 requires the work to be based on proper site information, a suitable geotechnical investigation, a documented design, controlled execution, and traceable records. In practice, the standard links the method chosen on site to the actual soil conditions and to the performance the project needs.

Project information and investigation

Clause 4 requires the information needed for the works to be available before execution starts. That includes site boundaries, services, obstructions, access, environmental restrictions, storage space, groundwater and other constraints. This matters because deep vibration can be affected by buried services, headroom limits, contaminated ground, water supply and slurry disposal.

Clause 5 requires the site and ground investigation to follow the EN 1997 series and to cover the full treatment zone and its zone of influence. The investigation has to identify ground layers, groundwater levels, obstructions, stiff or weak layers, liquefiable soils, contaminants and any conditions that could hinder penetration or reduce treatment performance. For rigid columns, the document also requires attention to water-table levels and, where relevant, the rock surface.

Materials and design basis

Clause 6 says materials have to match the design specifications and be suitable for the intended treatment and working life. Granular materials for compacted columns must be stable, durable, chemically inert and able to compact and flow properly; rigid-column mixes must provide the required strength, stiffness and durability and be suitable for the exposure class.

Clause 7 requires design in accordance with EN 1990 and EN 1997. The design has to define the treatment objectives, the required treated-ground properties, the treatment depth and extent, the performance indicators used to judge success, and any follow-up measures if the ground is excavated or filled later. It also requires consideration of settlement, heave, changes to the surface profile, effects of water injection, and risks to nearby structures.

Method selection and execution

Clause 7 also ties method selection to the actual soil. The standard points the reader to Annexes A to D for process descriptions and says the selected plant and equipment must suit the soil and the design requirements. It gives method-specific applicability conditions for granular columns and rigid columns, so the contractor cannot simply use one process everywhere.

Clause 8 requires a method statement and an approved execution plan before work starts. Site preparation must include identification of underground and overhead services, removal or accommodation of obstructions, and construction of a suitable working platform. The standard also requires setting out of treatment points, control of sequence and spacing, and construction tolerances for location and, for rigid columns, verticality.

Clause 8 further requires the treatment to be carried out by penetrating the ground with a vibrating tool, with pre-drilling, flushing, or other measures used where needed. It gives separate execution rules for deep vibratory compaction, vibrated compacted granular columns, and rigid columns, including how columns are built up, how continuity is controlled, and how deviations from the design are to be handled.

Quality control, records, and safety

Clause 9 requires supervision, inspection, monitoring and testing plans. These plans must define critical parameters, record production data, track material use, and include suitable field tests and monitoring where required. The standard also asks for observation of effects on nearby structures, including vibration, noise, ground movement and water effects.

Clause 10 requires daily records and other execution records sufficient to verify compliance with the design and execution plan. The records form part of the Geotechnical Construction Record (GCR).

Clause 11 requires compliance with safety, environmental and sustainability obligations. It also points to suitable working practices for heavy plant, possible liquefaction risks, and the need to control noise, dust and vibration.

What terms does oSIST prEN 14731:2026 define?

oSIST prEN 14731:2026 defines the main treatment methods and the tools used to execute them. These definitions matter because the execution requirements depend on whether the work is compaction, granular columns, or rigid columns.

  • Deep vibratory compaction - a deep-vibration ground treatment used mainly to increase relative density, typically in coarse-grained soil.
  • Vibrated compacted granular columns - continuous compacted granular columns formed by vibration to create a stiffer composite column-soil structure.
  • Rigid columns - continuous columns formed with a composite of binder and granular material, or concrete, that develop unconfined compressive strength.
  • Vibrating tool - the equipment inserted into the ground to generate vibration at depth.
  • Depth vibrator - a ground-treatment vibrator inserted into the ground, using eccentric weights to vibrate horizontally.
  • Top vibrator - a vibrator that remains above ground and drives a compaction probe.
  • Top-feed process - a way of forming granular columns by feeding material into an open hole from the top and compacting it in stages.
  • Bottom-feed process - a way of forming granular columns by delivering material to the base of the tool while the tool remains in the ground.

Who uses oSIST prEN 14731:2026?

oSIST prEN 14731:2026 is used by geotechnical designers, foundation contractors, site supervisors, quality managers and testing personnel. It is especially relevant for work on ground improvement, foundation support and liquefaction mitigation where execution quality and ground conditions strongly affect performance.

It also helps buyers and project managers write tender documents, method statements and inspection plans for deep vibration works.

What changed in oSIST prEN 14731:2026 from the previous edition?

oSIST prEN 14731:2026 will supersede EN 14731:2005. The European foreword states three significant technical changes:

  • the code has been updated to reflect current practice and evolved equipment
  • the code has been aligned with the second generation of the EN 1997 series
  • rigid columns installed with deep vibration technology and equipment have been introduced

Which standards are used with oSIST prEN 14731:2026?

oSIST prEN 14731:2026 works with several referenced standards that support design, materials, safety and testing.

StandardWhat it contributes
EN 206 (all parts)Concrete specification, production and conformity for rigid-column materials
EN 1990 (all parts)Basis of structural and geotechnical design
EN 1997 (all parts)Geotechnical design framework used throughout the document
EN 1997-1:2024Supervision, inspection and monitoring planning
EN 16228 (all parts)Safety requirements for drilling and foundation equipment
EN 1997-3:2025Referenced in the scope and testing provisions for ground treatment and load tests
EN ISO 22476-9Vane shear testing for assessing applicability in some rigid-column cases
EN 1097-1 and EN 1097-2Aggregate durability and fragmentation testing
EN 12390-2 and EN 12390-3Preparation and compressive testing of fresh rigid-column samples
EN 12504-1Core sampling and testing of hardened material

What does the oSIST prEN 14731:2026 document contain?

The document includes clauses for scope, normative references, terms, project information, geotechnical investigation, materials, design, execution, supervision, records and special requirements. It also includes informative annexes with method descriptions, figures for tool types and installation processes, and tables for supervision, inspection, monitoring and execution risks.

Annex B gives assessment methods for compactability, including formula-based checks and site-test layouts. Annex C shows the two main ways of installing vibrated compacted granular columns. Annex D shows the installation logic for rigid columns with semi-dry and pumped mixtures. Annex E gives an example of the daily report used to record deep vibratory works.

Relations

Effective Date
25-Jun-2025

Buy Documents

Draft

oSIST prEN 14731:2026 - BARVE

English language (45 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

Zavod za gradbeništvo Slovenije (ZAG) - Inšpekcija

ZAG inspection body for construction products, structures, and materials.

SA Slovenia Verified

Sponsored listings

Frequently Asked Questions

oSIST prEN 14731:2026 is a draft published by the Slovenian Institute for Standardization (SIST). Its full title is "Execution of special geotechnical works - Ground treatment by deep vibration". This standard covers: This document establishes general principles for the execution of soil treatment by deep vibration. The following types of treatment are covered by this document: - deep vibratory compaction to densify the ground as mentioned in EN 1997 3:2025, Annex I, Table I.1; - vibrated columns formed by inserted granular material laterally/radially compacted against the surrounding ground to form a stiff composite column-soil structure (vibrated compacted granular columns) as mentioned in EN 1997 3:2025, Annex I, Table I.2; - vibrated columns formed by inserted material developing unconfined compressive strength comprising a composite of binder and granular material (rigid columns) as mentioned in EN 1997 3:2025, Annex I, Table I.2. The following treatment methods are covered by this document: - methods in which depth vibrators, containing oscillating weights which cause horizontal vibrations, are inserted into the ground; - methods in which compaction probes are inserted into the ground using a vibrator, which remains above ground surface, and which oscillates in a vertical mode. Treatment methods are outlined in Annexes A, B, C and D. The following treatment methods, among others, are not included in this document: - dynamic compaction, dynamic replacement and other methods in which some form of treatment is applied to the ground surface; - uncompacted granular columns primarily used as drains; - explosive compaction.

This document establishes general principles for the execution of soil treatment by deep vibration. The following types of treatment are covered by this document: - deep vibratory compaction to densify the ground as mentioned in EN 1997 3:2025, Annex I, Table I.1; - vibrated columns formed by inserted granular material laterally/radially compacted against the surrounding ground to form a stiff composite column-soil structure (vibrated compacted granular columns) as mentioned in EN 1997 3:2025, Annex I, Table I.2; - vibrated columns formed by inserted material developing unconfined compressive strength comprising a composite of binder and granular material (rigid columns) as mentioned in EN 1997 3:2025, Annex I, Table I.2. The following treatment methods are covered by this document: - methods in which depth vibrators, containing oscillating weights which cause horizontal vibrations, are inserted into the ground; - methods in which compaction probes are inserted into the ground using a vibrator, which remains above ground surface, and which oscillates in a vertical mode. Treatment methods are outlined in Annexes A, B, C and D. The following treatment methods, among others, are not included in this document: - dynamic compaction, dynamic replacement and other methods in which some form of treatment is applied to the ground surface; - uncompacted granular columns primarily used as drains; - explosive compaction.

oSIST prEN 14731:2026 is classified under the following ICS (International Classification for Standards) categories: 93.020 - Earthworks. Excavations. Foundation construction. Underground works. The ICS classification helps identify the subject area and facilitates finding related standards.

oSIST prEN 14731:2026 has the following relationships with other standards: It is inter standard links to SIST EN 14731:2006. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

oSIST prEN 14731:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


SLOVENSKI STANDARD
01-november-2026
Izvedba posebnih geotehničnih del - Temeljenje z globinsko vibracijo
Execution of special geotechnical works - Ground treatment by deep vibration
Ausfürung von besonderen geotechnischen Arbeiten (Spezialtiefbau) -
Baugrundverbesserung durch Tiefenrüttelverfahren
Exécution de travaux géotechniques spéciaux - Amélioration de sol par vibration en
profondeur
Ta slovenski standard je istoveten z: prEN 14731
ICS:
93.020 Zemeljska dela. Izkopavanja. Earthworks. Excavations.
Gradnja temeljev. Dela pod Foundation construction.
zemljo Underground works
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

DRAFT
EUROPEAN STANDARD
NORME EUROPÉENNE
EUROPÄISCHE NORM
August 2026
ICS 93.020 Will supersede EN 14731:2005
English Version
Execution of special geotechnical works - Ground
treatment by deep vibration
Exécution de travaux géotechniques spéciaux - Ausfürung von besonderen geotechnischen Arbeiten
Amélioration des massifs de sol par vibration (Spezialtiefbau) - Baugrundverbesserung durch
Tiefenrüttelverfahren
This draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee
CEN/TC 288.
If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations
which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.

This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and
United Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.

Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without
notice and shall not be referred to as a European Standard.

EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2026 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 14731:2026 E
worldwide for CEN national Members.

Contents Page
European foreword . 4
1 Scope . 5
2 Normative references . 5
3 Terms and definitions . 6
4 Information needed for the execution of the works . 7
4.1 General. 7
4.2 Specific requirements . 8
5 Geotechnical investigation . 8
5.1 General. 8
5.2 Specific requirements for deep vibratory compaction . 9
5.3 Specific requirements for vibrated compacted granular columns . 10
5.4 Specific requirements for rigid columns . 10
6 Materials and products . 11
6.1 General. 11
6.2 Materials for deep vibratory compaction . 11
6.3 Materials for vibrated compacted granular columns . 11
6.4 Materials for rigid columns . 11
7 Considerations related to design . 12
7.1 General. 12
7.2 Geometry . 13
7.3 Factors to be considered for the selection of the ground treatment method . 13
7.4 Design validation . 14
7.5 Extent and layout of treatment . 14
8 Execution . 15
8.1 General. 15
8.2 Site preparation. 15
8.3 Working platform . 15
8.4 Setting out . 16
8.5 Sequence of treatment and column spacing . 16
8.6 Construction tolerances . 17
8.7 Treatment . 18
8.8 Deviations from the design or execution plan . 20
9 Supervision, inspection, monitoring and testing . 21
9.1 General. 21
9.2 Supervision Plan . 21
9.3 Inspection Plan . 22
9.4 Monitoring Plan . 24
9.5 Testing . 25
10 Records . 26
10.1 General. 26
10.2 Element . 27
10.3 Materials . 27
10.4 Subsequent works . 28
11 Special requirements . 28
11.1 General . 28
11.2 Safety . 28
11.3 Environmental protection . 28
11.4 Sustainability . 28
Annex A  (informative)Methods of ground treatment by deep vibration . 29
A.1 Ground treatment methods . 29
A.2 Tools for Vibro Techniques . 29
Annex B  (informative) Deep vibratory compaction . 30
Annex C  (informative) Installation of vibrated, compacted granular columns . 36
C.1 General . 36
C.2 Top-feed process . 36
C.3 Bottom-feed process . 37
Annex D  (informative) In Installation of vibrated rigid columns . 40
Annex E  (informative) Daily report example . 44
Bibliography . 45

European foreword
This document (prEN 14731:2026) has been prepared by Technical Committee CEN/TC 288 “Execution
of special geotechnical works”, the secretariat of which is held by AFNOR.
This document is currently submitted to the CEN Enquiry.
This document will supersede EN 14731:2005.
This document includes the following significant technical changes with respect to EN 14731:2005:
— amendment of the code reflecting current practice and evolved equipment;
— amendment of the code in line with the 2nd generation of the EN 1997 series;
— introduction of rigid columns, installed with deep vibration technology and equipment.
1 Scope
This document establishes general principles for the execution of soil treatment by deep vibration.
The following types of treatment are covered by this document:
— deep vibratory compaction to densify the ground as mentioned in EN 1997-3:2025, Annex I, Table I.1;
— vibrated columns formed by inserted granular material laterally/radially compacted against the
surrounding ground to form a stiff composite column-soil structure (vibrated compacted granular
columns) as mentioned in EN 1997-3:2025, Annex I, Table I.2;
— vibrated columns formed by inserted material developing unconfined compressive strength
comprising a composite of binder and granular material (rigid columns) as mentioned in
EN 1997-3:2025, Annex I, Table I.2.
The following treatment methods are covered by this document:
— methods in which depth vibrators, containing oscillating weights which cause horizontal vibrations,
are inserted into the ground;
— methods in which compaction probes are inserted into the ground using a vibrator, which remains
above ground surface, and which oscillates in a vertical mode.
Treatment methods are outlined in Annexes A, B, C and D.
The following treatment methods, among others, are not included in this document:
— dynamic compaction, dynamic replacement and other methods in which some form of treatment is
applied to the ground surface;
— uncompacted granular columns primarily used as drains;
— explosive compaction.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
EN 206 (all parts), Concrete — Specification, performance, production and conformity
EN 1990 (all parts), Eurocode — Basis of structural and geotechnical design
EN 1997 (all parts), Eurocode 7 — Geotechnical design
EN 1997-1:2024, Eurocode 7 — Geotechnical design - Part 1: General rules
EN 16228 (all parts), Drilling and foundation equipment — Safety
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at https://www.iso.org/obp/
— IEC Electropedia: available at https://www.electropedia.org/
3.1
deep vibratory compaction
type of ground treatment by deep vibration in which the main purpose is to increase the soil’s relative
density
Note 1 to entry: The treatment is applicable mainly to coarse grained and normally results in increased strength
and stiffness, reduced permeability and reduced susceptibility to liquefaction.
Note 2 to entry: Deep vibratory compaction is also termed as vibro floatation, vibro compaction or vibro
densification.
3.2
vibrated compacted granular columns
type of soil treatment by deep vibration in which a vibrating tool is used to form continuous compacted
granular columns from the maximum depth of penetration up to the top of the treatment zone, forming a
composite column-soil structure with an increased composite stiffness compared to the untreated state
Note 1 to entry: Depending on the inserted material, vibrated compacted granular columns are also termed stone
columns, gravel columns or sand columns.
Note 2 to entry: The treatment is applicable to a wide range of soils and in coarse grained materials some
densification may also be achieved. Two installation processes, the top-feed process and the bottom-feed process
are described in Annex C.
Note 3 to entry: Uncompacted granular columns primarily used as drains are covered in EN 15237 and not in this
document.
3.3
rigid columns
type of soil treatment by deep vibration in which a vibrating tool is used to form continuous columns with
an unconfined compressive strength comprising a composite of binder and granular material or concrete
Note 1 to entry: Rigid columns can be designed as class BII ground improvement according to EN 1997-3.
3.4
vibrating tool
item of equipment which is inserted into the ground to cause vibration at depth; commonly a depth
vibrator containing oscillating weights or a compaction probe inserted into the ground using a top
vibrator which remains above ground surface
3.5
depth vibrator
ground treatment equipment used in the installation of vibrated columns and for vibro compaction,
which vibrates horizontally by means of an eccentric weight rotating around its longitudinal axis, and is
inserted into the ground, which can be assisted by air or water flushing
Note 1 to entry: Penetration can also be preceded by predrilling.
3.6
top vibrator
vibrator which remains above the ground surface and is connected to a compaction probe
3.7
compaction probe
tool for installation of vibrated columns and vibro compaction, which is inserted into the ground to
transmit vibrations from a top vibrator which remains above the ground surface; wings, drainage or
water flushing can be provided to facilitate the compaction process
3.8
top-feed process
method of constructing vibrated compacted granular columns in which the hole formed by the vibrating
tool remains open and allows specified granular material to be fed directly into the top of the hole and
which is then compacted by the vibrator or the compaction probe in stages
Note 1 to entry: The penetration can be assisted by flushing with air and/or water and/or pre-drilling.
Note 2 to entry: The process is described in Annex C.
3.9
bottom-feed process
method of constructing vibrated compacted granular columns in which specified granular material is
delivered directly to the base of the vibrating tool via a feed pipe attached to the depth vibrator or through
the hollow compaction probe, the vibrating tool remains in the soil during the construction of the column
to maintain the stability of the hole and to compact the inserted material
Note 1 to entry: The penetration can be assisted by flushing with air and/or water and/or pre-drilling.
Note 2 to entry: The process is described in Annex C.
4 Information needed for the execution of the works
4.1 General
4.1.1 Prior to the execution of the work, all necessary information shall be made available.
4.1.2 The information shall include but is not limited to:
— any legal or statutory restrictions;
— location of main grid lines or reference points for setting out treatment or column positions;
— location and condition of structures, roads, services, etc. on or adjacent to the works, including any
necessary surveys;
— minimum requirements for a quality management system, including supervision, inspection and
monitoring;
— site geometry (boundaries, topography, access points, slopes, etc.);
— available space for storage of materials, treatment and/or disposal of spoil or waste materials;
— location of existing underground structures, services and archaeological constraints, known
contaminants and potential presence of unexploded ordnance and its location;
— site constraints (environmental restrictions including noise, vibration, displacements, pollution) and
potential seasonal weather impacts (e.g. frozen surface layers, storms or flooding);
— above ground lines, services and headroom restrictions.
— future or ongoing activities such as dewatering, tunnelling, deep excavations and raising of site levels.
4.2 Specific requirements
The information required in relation to the practical aspects of the execution of ground treatment shall
include:
— specific project design objectives which the execution of the ground treatment is intended to meet;
NOTE These objectives typically include provisions of increased bearing capacity, reduced
compressibility, reduced liquefaction potential, reduced collapse potential; change of hydraulic conductivity or
other requirements;
— water supply and slurry disposal constraints for the wet process of installing vibrated compacted
granular columns or deep vibratory compaction.
5 Geotechnical investigation
5.1 General
5.1.1 All site and ground investigation shall be executed in accordance with the EN 1997 series and the
design requirements of the project.
5.1.2 Ground level at any point of investigation or testing shall be given relative to the recognized
national datum or to a fixed reference chart datum or agreed project site datum.
5.1.3 The extent and depth of the site and ground investigation shall cover the full treatment zone and
its zone of influence and shall be sufficient to determine the characteristic ground conditions and
topography of the site and to identify and locate all ground formations, layers for the definition of
geotechnical units, other geological features and ground water levels affecting the execution of the works.
5.1.4 All information from site investigations shall be made available in accordance with the
requirements of Clause 4.
5.1.5 Some existing or planned man-made fills may be heterogeneous, and further examination may be
required to determine representative geotechnical descriptions.
5.1.6 Obstructions, hard layers, cobbles and boulders within the ground which could influence or
prevent the insertion of the vibrating tool should be identified.
5.1.7 The presence of ground conditions which could affect the performance of treatment shall be
identified including, but not limited to:
— very stiff, very dense or cemented layers;
— very soft, very loose layers or singular local areas;
— presence, extent and thickness of any strata that might be sensitive to water infiltration or to change
of their stress state caused by vibrating tools;
— soils with potential for collapse or excessive settlement; soils with liquefaction potential;
— layers currently subject to ongoing or future consolidation and/or creep movements;
— presence of pre-treated soil, which might have an adverse effect during penetration;
— mining beneath the site;
— site stability problems (e.g. slope stability).
5.1.8 Piezometric levels of all water-tables and permeability of the soils.
5.1.9 Particular attention shall be paid to artesian conditions.
5.1.10 Any contaminants and pollutants in the soil or the groundwater should be identified.
5.2 Specific requirements for deep vibratory compaction
5.2.1 Special consideration shall be given to the geometric extent of compactable granular soils and the
location and extent of any layers restricting the efficiency of the treatment process or preventing it
outright like clay, silt and organic layers and layers impeding drainage.
NOTE Some methods of field investigation might produce data that result in an inconclusive determination of
boundaries between geotechnical units under certain conditions like highly laminated soil or dense layers above
very soft layers.
5.2.2 Where clay, silt or organic soils are present, some or all of the properties mentioned in 5.2.3 may
require clarification.
5.2.3 The following geotechnical properties of coarse-grained soils are relevant to the design and
execution of ground treatment by deep vibratory compaction:
— Type of grain material (silica, carbonite, volcanic, etc.);
— particle size distribution and fines content (silt and clay);
— in situ density index (relative density);
— drained and undrained shear parameters;
— compactibility;
— hydraulic conductivity;
— hardness of the grain and carbonate content;
— inter-particle bonding caused by cementation, suction or cohesion.
5.3 Specific requirements for vibrated compacted granular columns
5.3.1 Particular attention shall be given to the determination of physical and geotechnical ground
properties required for the design and execution of the ground treatment by vibrated compacted
granular columns, for example:
— compressibility;
— compactibility;
— consistency limits;
— plasticity;
— drained and undrained shear parameters;
— sensitivity;
— hydraulic conductivity.
5.3.2 Certain ground conditions that may result in a loss of lateral support need particular
consideration, including, but not limited to:
— presence and extent of peat and organic soil;
— presence of biodegradable fill including domestic waste;
— insufficient shear strength.
5.4 Specific requirements for rigid columns
5.4.1 Particular attention shall be paid to the following aspects, which are relevant to the execution of
rigid columns:
— presence of coarse, highly permeable soils or cavities (natural or artificial), which can cause a sudden
loss of concrete, mortar or grout during placement, and thus can require special measures;
— presence, strength and deformation characteristics of soft highly compressible soils, such as very low
strength clay or peat, which can cause problems during the extraction of the tool and the placing of
concrete or other mixtures (deformation or instability);
— underground strata with the potential for high groundwater flows or seepages;
— unfavourable chemistry of groundwater and ground and water temperatures, if required;
— detrimental chemistry of waste materials;
— thickness and characteristics of bearing strata.
5.4.2 The piezometric levels of all water-tables within the zone of influence shall be monitored
separately and over a sufficient period of time to estimate the highest piezometric levels which can occur
during construction of the rigid columns following the requirements of the EN 1997 series.
5.4.3 When rigid columns are required to reach bedrock, the rock surface level shall be determined.
6 Materials and products
6.1 General
6.1.1 Imported materials may be naturally occurring sands and gravels, crushed rock or appropriate
recycled materials. Quality control testing for selected materials is described in 9.5.4.
6.1.2 The properties of all materials shall be in accordance with the design specifications.
6.1.3 When checking the availability of materials, the impact of transportation on sustainability should
be considered.
6.2 Materials for deep vibratory compaction
6.2.1 Material may be added during deep vibratory compaction. This may be site won or imported
natural granular material.
6.2.2 Added materials shall be sufficiently stable and chemically inert during the treatment process and
subsequent working life in the anticipated soil and groundwater conditions to achieve the specified
requirements of the treated soil volume.
6.3 Materials for vibrated compacted granular columns
Material used to form vibrated compacted granular columns shall be:
— hard, robust, durable and chemically inert to remain sufficiently stable during column installation
and throughout the subsequent working life of the ground treatment;
— graded appropriately to aid compaction to form a dense column fully interlocked with the
surrounding ground and in compliance with any other requirements such as drainage;
— compatible with the ground improvement plant used and able to flow freely within the hole for top-
feed or through the delivery feed systems for bottom-feed systems without arching or blocking;
— containing minimal fines content, to avoid installation and compaction problems during construction
and the service life.
6.4 Materials for rigid columns
6.4.1 The mix design and resulting properties shall provide sufficient strength, stiffness and durability
to meet the project requirements.
6.4.2 All materials shall be suitable for the environmental exposure class.
6.4.3 All materials shall be suitable for installation.
6.4.4 Cementitious materials may conform to the EN 206 series.
NOTE For rigid columns with semi-dry compacted mixtures, materials typically do not conform to the EN 206
series.
6.4.5 Other materials can be used if they are suitable for installation and their performance conforms
to the design requirements. Suitability of those mixtures should be verified by testing, comparable
experience or other regulatory approvals.
7 Considerations related to design
7.1 General
7.1.1 The design of ground treatment by deep vibration shall be in accordance with the EN 1990 series
and the EN 1997 series.
7.1.2 The information on ground conditions shall be assessed to determine the suitability for treatment
by deep vibration.
7.1.3 The following shall be defined by the design of the ground treatment:
a) objectives of the ground treatment
NOTE These typically include provisions of increased bearing capacity, reduced compressibility; reduced
liquefaction potential, reduced collapse potential; change of hydraulic conductivity or other requirements.
b) required geotechnical properties of the treated soil (e.g. shear strength, stiffness, or hydraulic
conductivity);
— for diffused soil treatment, the representative soil properties should be assumed considering
their variation over the treated volume;
— for discrete soil treatment, the properties of soil and column after treatment should be considered
as separate representative values;
c) criteria for determining the treatment depth and extent;
d) target performance and the measurable indicators and parameters for the assessment of the
treatment to meet the design criteria;
e) particular warnings where filling or excavation subsequent to treatment takes place, proposals for
re-compaction, if necessary.
7.1.4 Due to the variable nature of the ground, variations in performance are to be expected even after
treatment and this should be considered.
7.1.5 Heave or settlement will occur during treatment should be anticipated and allowed for in the
design.
7.1.6 Settlements subsequent to treatment (e.g. from consolidation or creep of the ground) should be
assessed and the effect this may have on the performance of the ground treatment should be evaluated.
7.1.7 Changes to the surface profile after treatment may occur and should be assessed to determine the
effect this may have on the performance of the treatment.
NOTE Post-treatment changes to the original design (e.g. excavation depth, fill heights or foundation levels)
can represent a change in the loading conditions and their effect needs to be assessed.
7.1.8 Some deep vibration processes require the use of large quantities of water. The effects, if any, of
inserting water into the ground in the treatment zone and the surrounding ground shall be assessed in
the design.
7.1.9 The possibility of adverse effects on existing adjacent structures arising from ground movements,
pore water pressure changes or vibrations induced by the treatment shall be reviewed during the design.
7.1.10 In cases where adverse effects on adjacent structures cannot be excluded, a pre-condition survey
may need to be carried out as described in 11.4.
7.1.11 Where vibrated compacted granular columns are also required to function as drains, adequate
provision should be made for surface drainage. If the existing topsoil is not adequate a surface drainage
blanket should be provided. Attention should be given to the drainage properties of the working platform.
7.2 Geometry
7.2.1 Geometrical construction tolerances given in 8.5 shall be considered in the design.
7.2.2 If the specified geometrical tolerances are exceeded, the potential overloading of a rigid column
shall be considered and suitable measures shall be taken as necessary.
7.3 Factors to be considered for the selection of the ground treatment method
7.3.1 The selected method, plant and equipment for execution of the ground treatment works shall be
chosen to suit for the existing soil conditions and the design requirements. Descriptions of various
treatment processes are given in Annexes A, B, C and D.
NOTE This can often be established on the basis of previous comparable experience.
7.3.2 Deep vibratory compaction.
7.3.2.1 For assessment of the compactibility of the ground, refer to Annex B.
7.3.2.2 A minimum treatment depth is required for the selected method to be effective which in turn
is dependent on the plant, equipment and required performance criteria.
7.3.3 Vibrated compacted granular columns.
7.3.3.1 If the undrained shear strength of organic or cohesive soils is 5 ≤ S ≤ 10 kN/m , applicability
u
shall be established through field tests or comparable experience.
7.3.3.2 The top-feed process shall only be used where the hole formed by the vibrating tool remains
open. Otherwise, the bottom-feed process shall be used.
7.3.4 Rigid columns with semi-dry compacted mixtures
If the undrained shear strength of organic or cohesive soils is 5 ≤ S ≤ 10 kN/m and the thickness of these
u
layers is greater than 1 m, applicability shall be established through
a) field tests or comparable experience; or
b) by meeting the following conditions:
— The base of a column shall not be founded on any strata layers with an undrained shear strength
less than 15 kN/m .
— Installation of the rigid column shall only be permitted if the highly compressible very low
strength fine grained soil has been pre-treated with vertical drainage elements (e.g. pre-
fabricated vertical drains or vibrated compacted granular columns) in case the excessive built-up
of pore water pressure is to be expected.
7.3.5 Rigid columns with pumped mixtures.
7.3.5.1 The undrained shear strength of organic or cohesive soils shall be S ≥ 15 kN/m .
u
Intermediate layers with an undrained shear strength of 5 ≤ S ≤ 15 kN/m are acceptable in case their
u
thickness does not exceed 1 m.
7.3.5.2 In organic or cohesive layers with an undrained shear strength 5 ≤ S ≤ 15 kN/m with a
u
thickness of more than 1 m, rigid columns can be used, if:
a) field tests or comparable experience sufficiently prove the applicability of the treatment method; or
b) the meeting of the following conditions:
— Vane shear tests according to EN ISO 22476-9 shall be conducted in the field. The measured
sensitivity from this test shall be less than 8 to avoid liquefaction of the soil during execution.
— Layers with an undrained shear strength S ≤ 15 kN/m shall not be present within the zone of
u
influence below column toe level.
— Prior to the installation of the rigid column, the soil shall be pre-treated with drain elements (e.g.
pre-fabricated vertical drains or vibrated compacted granular columns) in case the excessive
built-up of pore water pressure is to be expected.
— For S < 10 kN/m , the total thickness of the organic layer shall not exceed 4 m. For
u
2 2
10 kN/m ≤ S < 15 kN/m the total thickness of the organic layer shall not exceed 8 m.
u
2 2
— For soils with an undrained shear strength 10 kN/m ≤ S < 15 kN/m and a thickness of less than
u
4 m, drain elements can be omitted in case continuous electronic recording and documentation
ensures that the material is discharged continuously through the vibrating tool.
7.3.4.3 The amount and extent of reinforcement needs to be specified in the design for permanent
and temporary verification cases as well as installation effects.
7.4 Design validation
7.4.1 It shall be validated that the treatment objectives as set out in the design have been achieved.
7.4.2 Suitable means of validation of the specified treatment objectives should be defined prior to
commencement of soil treatment.
7.4.3 Appropriate methods of testing are described in 9.5.
7.4.4 The type and frequency of testing compatible with the requirements for quality control and
performance of the treatment shall be specified in the design. In addition to or instead of testing, other
methods of validation may be applied.
7.4.5 The evaluation of monitoring records and production data shall be part of the supervision,
inspection and monitoring process.
7.5 Extent and layout of treatment
7.5.1 The execution design shall define the treatment area and location of treatment points, and the
upper and lower levels of the treatment zone.
7.5.2 Each treatment point shall be identified by a reference number and its plan location shall be
related to fixed datum points, grid lines or given in absolute or relative coordinates.
7.5.3 If natural or artificial obstructions are encountered, their impact on the performance of the
treatment needs to be assessed and adequate measures need to be considered and implemented.
7.5.4 The treatment may need to extend beyond the footprint of a structure to be built on the treated
ground. This is the case where, for example, a primary objective of treatment is to reduce the
susceptibility to liquefaction in case of an earthquake.
7.5.5 For foundation support, the depth of treatment shall be specified as follows:
— in full-depth treatment, the depth vibrator or compaction probe shall reach the competent layer
identified in the ground model or specified in the geotechnical design model;
NOTE The column lengths can vary due the geological variability (geometry and properties).
— in partial-depth treatment, the depth of the treatment shall be adequate to improve the depth of
ground within the zone of influence of a particular foundation system to meet the specified stability
and serviceability criteria.
7.5.6 Deformations below treatment depths shall be assessed.
8 Execution
8.1 General
8.1.1 The ground improvement works shall be carried out according to a method statement. The
method of treatment and equipment employed shall be chosen to achieve the depth of treatment and the
design objectives in the prevailing ground conditions. Account shall be taken of concurrent site activities
and all equipment movement necessary to properly carry out the ground treatment. Suitably trained and
experienced personnel shall be in charge of the execution works.
8.1.2 Before starting the work a plan of execution describing the equipment, the installation method
and a global sequence of installation should be available and approved.
8.2 Site preparation
8.2.1 The site shall be prepared in such a way that operations can be carried out safely and efficiently.
Prior to commencement of ground treatment, services in the ground and overhead shall be identified and
clearly marked on site or relocated.
8.2.2 Any near-surface natural or artificial obstructions shall be identified prior to the commencement
of ground treatment and removed with any resulting excavations or voids filled with well compacted
granular material. As an alternative, the layout of the treatment shall be altered to accommodate the
obstructions.
8.3 Working platform
8.3.1 A working platform shall be constructed suitable for the safe operation of heavy ground treatment
plant and equipment and any activities.
8.3.2 The working platform shall be of sufficient size, above the water table and levelled horizontally.
8.3.3 Working platform requirements shall be specified, including a functional drainage system,
considering national provisions, where relevant.
8.3.4 The material used for the construction and maintenance of the working platform shall comply
with the specified requirements and be specified.
8.3.5 The stability of the working platform should be verified according to the EN 1997 series and
EN 16228-1:2014+A1:2021, Annex F – Ground pressure calculation for crawler mounted drilling and
foundation equipment.
NOTE Guidance for stability and the design of working platform can be found in the EFFC/DFI Guide to
Working Platforms or other national guidance.
8.3.6 The working platform and the access ramps shall be maintained such that they remain functional
at all times during the construction period.
8.3.7 Special considerations are required when working over water.
8.4 Setting out
8.4.1 All treatment points shall be either set out within the specified tolerances or the rig shall be
positioned within the specified tolerances with adequate measurement devices (e.g. GPS-system).
8.4.2 The levels of the working platform relative to the specified upper and lower treatment levels shall
be checked.
8.5 Sequence of treatment and column spacing
8.5.1 The sequence of treatment at individual treatment points and the general direction of treatment
across large areas should be considered with regard to the effectiveness of the treatment and the
presence of adjacent, buried or overhead structures and services and specified in the execution plan.
8.5.2 Compacted granular columns should not generally be installed closer than 2 diameters centre to
centre of adjacent columns.
NOTE This spacing can be reduced if based on comparable experience or testing for small treatment areas is
carried out.
8.5.3 For large treatment areas a greater spacing may be required.
8.5.4 When planning the sequence of installation of rigid columns, the following additional potential
effects should be considered:
— Necking:
Soil movement or slumping causing a localized diameter reduction of a column which has not chieved
the initial set.
— Breaking or damage to the shaft:
Soil movement causing overloading of a column which has taken initial set.
— Displacement:
Soil movements causing a lateral displacement of a hardened column.
— Excess pore water pressure:
Excess pore water pressure can cause a reduction or loss of shear strength of the surrounding
ground.
Table 1 — Possible countermeasures
Possible countermeasures
Increase Installation Installation Decrease Low Re- Drain
design fresh next to fresh next to column plasticity inforce- elements
Effect spacing hard fresh diameter material ment
Necking X X  X X  X
Breaking X  X X  X X
Displacement X   X   X
Excess pore
X X  X   X
water pressure
8.5.5 Local or comparable experience can influence the proposed sequence of installation.
8.5.6 If the minimum spacing for rigid columns according to Figure 1 are maintained, the execution
risks according to Table 1 are minimized.

Key
X column spacing = X x Diameter (centre to centre)
semi-dry mixtures
pumped mixture
Figure 1 — Recommended spacing for rigid columns for reduced execution risks
8.5.7 The spacing of rigid columns can be reduced below the recommendations of Figure 1 based on
comparable experience, testing or application of suitable countermeasures according to Table 1.
8.6 Construction tolerances
8.6.1 Unless otherwise specified, treatment points shall be installed within the following construction
tolerances:
8.6.1.1 Plan location measured at the working platform level:
— ≤ 0,15 m for non-rigid columns;
— ≤ 0,10 m for rigid columns.
8.6.1.2 Verticality tolerances for rigid columns ≤ 0,05 m/m. In case of unguided systems without
leaders, the verticality shall be measured
...