Abstract

This document specifies the characteristics of three-pole circuit breakers, temperature compensated with a rated current from 20 A to 50 A, used in aircraft on-board circuits at a temperature between −55 °C and 90 °C at an altitude of 15 000 m max.
These circuit breakers are operated by a push-pull type single pushbutton (actuator), with delayed action "trip-free" tripping
They will continue to function up to the short-circuit current.

Status
Not Published
Public Enquiry End Date
30-Oct-2026
Technical Committee
I13 - Imaginarni 13
Current Stage
4020 - Public enquire (PE) (Adopted Project)
Start Date
04-Sep-2026
Due Date
22-Jan-2027
Completion Date
02-Nov-2026

Buy Documents

Draft

oSIST prEN 2665-004:2026

English language (12 pages)
Preview
Preview
e-Library read for
×1 day

oSIST prEN 2665-004:2026 is a draft European Standard from CEN, prepared by ASD-STAN, for aerospace three-pole circuit breakers with UNC thread terminals. It specifies the characteristics, dimensions, electrical and mechanical performance, marking, and delivery codes for temperature compensated breakers rated from 20 A to 50 A for aircraft on-board circuits.

What does oSIST prEN 2665-004:2026 specify?

oSIST prEN 2665-004:2026 specifies three-pole, temperature compensated circuit breakers for aircraft on-board circuits used between -55 °C and 90 °C and up to 15 000 m altitude. These breakers use a push-pull type single pushbutton actuator, delayed-action trip-free tripping, and are intended to keep functioning up to short-circuit current.

The document is organized into:

  • Clause 1 - Scope
  • Clause 2 - Normative references
  • Clause 3 - Terms and definitions
  • Clause 4 - Dimensions and mass
  • Clause 5 - Characteristics
  • Clause 6 - Designation
  • Clause 7 - Rated current code
  • Clause 8 - Delivery codes
  • Clause 9 - Marking
  • Clause 10 - Technical specification

In practice, the standard gives the product definition, the installation interface, the electrical behavior, and the identification rules needed to specify, buy, test, and install the breaker consistently.

What are the key requirements of oSIST prEN 2665-004:2026?

oSIST prEN 2665-004:2026 combines dimensional control, mechanical robustness, environmental endurance, and electrical trip performance. For a user, that means the breaker is not only sized to fit, but also qualified for the intended aircraft conditions and protection duty.

Dimensions and installation

Clause 4.1 requires the configuration, dimensions, and tolerances shown in Figure 1, with dimensions in millimetres except for the 8-32 UNC terminal thread. The illustration is not the only acceptable shape, but the stated dimensions are binding, which matters when checking interchangeability and panel fit.

Clause 4.2 defines the electrical state: pushbutton released means CB open, and pushbutton pressed means CB closed. The load and supply can be inverted, which simplifies wiring practice.

Clause 4.3 limits mass to 180 g maximum for delivery code A including hardware, and Clause 4.4 requires panel mounting to follow EN 2665-001. This helps buyers and installers control weight and confirm that the mounting matches the approved family.

Mechanical and environmental characteristics

Clause 5.2 requires fasteners to comply with EN 6113 and gives installation torque values for the attaching nut and connection hardware. It also includes vibration, shock, and mechanical endurance requirements, so qualification testing covers both handling loads and in-service service life.

Clause 5.3 covers humidity, corrosion, contaminating liquids, and lightning-caused overvoltage by reference to EN 2665-001. These items matter because aircraft equipment must keep operating after exposure to moisture, contaminants, and electrical stress.

Electrical performance

Clause 5.4.1 sets the operating circuit voltage range at 115 V to 200 V AC, 360 Hz to 800 Hz, three phases. Clause 5.4.2 limits voltage drop at rated current, so the breaker’s internal losses stay under control.

Clauses 5.4.3 and 5.4.4 define the minimum and maximum tripping thresholds and overload trip times at different temperatures and altitude conditions. This tells a designer or test lab how quickly the breaker must respond under normal overloads.

Clause 5.4.5 defines short-circuit performance, including the prospective currents, altitude conditions, and the CO and OCO operating sequence from EN 3841-305. Clause 5.4.6 then sets no-load and load endurance, Clause 5.4.7 covers dielectric rigidity, and Clause 5.4.8 covers insulation resistance. Together, these clauses show whether the breaker can interrupt faults, survive repeated operation, and retain electrical isolation.

Identification and supply

Clauses 6 to 9 define designation, rated current code, delivery codes, and marking. This is the part that supports ordering, traceability, and correct assembly of the breaker and its hardware.

What terms does oSIST prEN 2665-004:2026 define?

  • Trip-free - A tripping action that opens the circuit breaker even if the actuator is held in the operated position.
  • Actuator - The push-pull type single pushbutton used to operate the circuit breaker.
  • CB - Circuit breaker, the device identified in Figure 2 as open or closed.
  • Rated current - The current rating used throughout the document for classification, marking, and performance checks.
  • Load - The circuit side shown in Figure 2 that receives power through the breaker.
  • Supply - The power source side shown in Figure 2; the document allows the load and supply to be inverted.
  • CO and OCO - The short-circuit test operation sequence used with EN 3841-305, meaning break and make-break operations.

Who uses oSIST prEN 2665-004:2026?

Aircraft electrical engineers use oSIST prEN 2665-004:2026 when selecting a breaker for a circuit that must work within the stated voltage, temperature, and altitude limits. Test laboratories use it to verify tripping, short-circuit behavior, endurance, dielectric rigidity, and insulation resistance.

Manufacturers use it to design the breaker body, actuator, terminals, mounting arrangement, and hardware. Quality managers and buyers use it to check part marking, delivery codes, and the hardware kit arrangement before release or purchase.

Installers and maintenance teams use it for panel mounting, tightening torque, and identification on the product and packaging.

What changed in oSIST prEN 2665-004:2026 from the previous edition?

oSIST prEN 2665-004:2026 will supersede EN 2665-004:2013. The foreword lists these technical changes:

  • revised short-circuit values in Table 5
  • mass changed from 162 g to 180 g in 4.3
  • modified external diameter of the button in Figure 1

Which standards are used with oSIST prEN 2665-004:2026?

  • EN 2350 - supplies the terms and definitions used in Clause 3.
  • EN 2665-001 - provides panel mounting, material and surface treatment, environmental characteristics, insulation resistance, and the technical specification.
  • EN 3841-305 - provides the short-circuit test method and the meaning of CO and OCO.
  • EN 6113 - specifies the connecting and attachment hardware used with the breaker.
  • SAE-AMS-STD-595 - provides the colour references used for the black and white markings in Figure 1.
  • TR 6083 - is cited with the panel cut-out positioning shown in Figure 1.

What does the oSIST prEN 2665-004:2026 document contain?

oSIST prEN 2665-004:2026 contains two main figures and nine tables that drive design and verification. Figure 1 gives the configuration, dimensions, tolerances, terminal thread, actuator, and panel-mounting features; Figure 2 gives the electrical diagram and the open/closed states.

The tables cover nominal voltage, voltage drop, tripping thresholds, overload trip time, short-circuit values, endurance, dielectric rigidity, rated current code, and delivery codes. That makes the document useful both for product design and for acceptance testing.

Relations

Effective Date
08-Jan-2025

Buy Documents

Draft

oSIST prEN 2665-004:2026

English language (12 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

BUREAU VERITAS Certification Germany

Bureau Veritas certification in Germany.

DAKKS Germany Verified

Element Materials Technology

Materials testing and product certification.

UKAS United Kingdom Verified

AQMS Ltd.

AQMS provides ISO certification to SMEs across the UK.

UKAS United Kingdom Verified

Sponsored listings

Frequently Asked Questions

oSIST prEN 2665-004:2026 is a draft published by the Slovenian Institute for Standardization (SIST). Its full title is "Aerospace series - Circuit breakers, three-pole, temperature compensated, rated current 20 A to 50 A - Part 004: UNC thread terminals - Product standard". This standard covers: This document specifies the characteristics of three-pole circuit breakers, temperature compensated with a rated current from 20 A to 50 A, used in aircraft on-board circuits at a temperature between −55 °C and 90 °C at an altitude of 15 000 m max. These circuit breakers are operated by a push-pull type single pushbutton (actuator), with delayed action "trip-free" tripping They will continue to function up to the short-circuit current.

This document specifies the characteristics of three-pole circuit breakers, temperature compensated with a rated current from 20 A to 50 A, used in aircraft on-board circuits at a temperature between −55 °C and 90 °C at an altitude of 15 000 m max. These circuit breakers are operated by a push-pull type single pushbutton (actuator), with delayed action "trip-free" tripping They will continue to function up to the short-circuit current.

oSIST prEN 2665-004:2026 is classified under the following ICS (International Classification for Standards) categories: 49.060 - Aerospace electric equipment and systems. The ICS classification helps identify the subject area and facilitates finding related standards.

oSIST prEN 2665-004:2026 has the following relationships with other standards: It is inter standard links to SIST EN 2665-004:2014. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

oSIST prEN 2665-004:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Dimensions and mass
  • 4.1 Dimensional characteristics
  • 4.2 Electrical diagram
  • 4.3 Mass
  • 4.4 Panel mounting
  • 5 Characteristics
  • 5.1 Material, surface treatment
  • 5.2 Mechanical characteristics
  • 5.3 Environment characteristics
  • 5.4 Electrical characteristics
  • 1 CO + 2 OCO
  • 6 Designation
  • 7 Rated current code
  • 8 Delivery codes
  • 9 Marking
  • 10 Technical specification
  • Bibliography

1 Scope

This document specifies the characteristics of three-pole circuit breakers, temperature compensated with a rated current from 20 A to 50 A, used in aircraft on-board circuits at a temperature between −55 °C and 90 °C at an altitude of 15 000 m max.

These circuit breakers are operated by a push-pull type single pushbutton (actuator), with delayed action “trip-free” tripping They will continue to function up to the short-circuit current.

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 2350, Aerospace series - Circuit breakers - Technical specification EN 2665-001, Aerospace series - Circuit breakers, three-pole, temperature compensated, rated currents 20 A to 50 A - Part 001: Technical specification EN 3841-305, Aerospace series - Circuit breakers - Test methods - Part 305: Short-circuit performance EN 6113, Aerospace series - Circuit breaker, connecting and attachment hardware

SAE-AMS-STD-595, Colors used in Government Procurement

3 Terms and definitions

For the purposes of this document, the terms and definitions given in EN 2350 apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:

  • ISO Online browsing platform: available at https://www.iso.org/obp/
  • IEC Electropedia: available at https://www.electropedia.org/

4 Dimensions and mass

4.1 Dimensional characteristics

The circuit breakers do not have to correspond to the pictorial illustration, only the dimensions given shall be adhered to.

Dimensions are in millimetres with exception terminal thread 8-32 UNC. Configuration, dimensions and tolerances shall be in accordance with Figure 1.

Published by Society of Automotive Engineers (SAE), available at: https://www.sae.org/

oSIST prEN 2665-004:2026 prEN 2665-004:2026 (E)

Key 1 push button released 2 black colour according to SAE-AMS-STD-595 3 white 4 marking, see Clause 6 5 push button pressed 6 attachment nut 7 lock washer 8 1 max. to 3 max.

9 positioning lug in accordance with the panel cut-out, as per TR 6083C202 10 rated current marking (white on black) Figure 1 — Configuration, dimensions and tolerances

oSIST prEN 2665-004:2026 prEN 2665-004:2026 (E)

4.2 Electrical diagram

Electrical diagram shall be in accordance with Figure 2.

Push button released: CB open.

Push button pressed: CB closed.

Key 1 load 2 supply Load and supply can be inverted.

Figure 2 — Electrical diagram

4.3 Mass

180 g max. (delivery code A including hardware).

4.4 Panel mounting

Panel mounting shall be in accordance with EN 2665-001.

5 Characteristics

5.1 Material, surface treatment

Material and surface treatment shall be in accordance with EN 2665-001.

5.2 Mechanical characteristics

5.2.1 Fasteners

Fasteners shall be in accordance with EN 6113.

5.2.2 Recommended tightening torque of attaching nut for installation

(5,25 ± 0,25) N.m

...