SIST EN 6059-502:2027
(Main)Aerospace series - Electrical cables, installation - Protection sleeves - Test methods - Part 502: Resistance to electrical arcs
- Abstract
This document specifies a method of assessing the behaviour of protection sleeves or conduits subject to an external electric arc at 115 VAC, 800 Hz.
This document is used in conjunction with EN 6059-100.
The primary aim of this test is to produce, in a controlled fashion, electric arcs at the immediate vicinity of a protection sleeve or conduit and to examine possible consequences on the protected cables bundle, which supposed to be maintained in a safe condition.
These electric arcs are representative of those which may occur in service when a typical adjacent cable bundle is severely damaged and leading to an electrical arc default.
In order to optimize thickness and mass of such protection, it is necessary to associate a nominal current limit In to each sleeves or conduits construction.
Two levels of prospective fault current are specified for all protection sizes.
NOTE This test requires specifics attentions and protections toward operator and personnel applying this test, refer to 6.2 for further details.
- Status
- Published
- Public Enquiry End Date
- 05-May-2024
- Publication Date
- 22-Nov-2026
- Technical Committee
- I13 - Imaginarni 13
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 23-Nov-2026
- Due Date
- 28-Jan-2027
- Completion Date
- 23-Nov-2026
SIST EN 6059-502:2027 is a Slovene standard in the aerospace series for testing protection sleeves and conduits used on electrical cable installations. It specifies a controlled method for assessing how a sleeve or conduit behaves when exposed to an external electric arc at 115 VAC, and how well it protects the adjacent cable bundle. The document is used with EN 6059-100 and is intended for manufacturers, test labs, and aerospace users who need to compare sleeve constructions under a repeatable fault condition.
What does SIST EN 6059-502:2027 specify?
SIST EN 6059-502:2027 specifies the scope, specimen preparation, test equipment, test method, and acceptance requirements for resistance to electrical arcs. The standard is organized into Clauses 1 to 8, covering scope, normative references, specimen requirements, preparation, apparatus, method, and requirements.
The test is designed to create arc events next to a protection sleeve or conduit and then inspect the protected cable bundle for damage. In practice, that means the document is not just about surviving an arc - it is about whether the protected conductors stay in a safe condition after the event.
What are the key requirements of SIST EN 6059-502:2027?
SIST EN 6059-502:2027 sets up a repeatable arc-resistance test around two cable bundles: a target bundle and a protected bundle. The most important requirements are in Clauses 4 to 8.
- Traceable specimens and preconditioning - Clause 4 requires protection sleeves or conduits of traceable origin, and they normally have to pass the EN 6059-501 voltage proof test first. For a buyer or qualifier, this means the sample under test must already be known and suitable for comparison.
- Representative bundle construction - Clause 5 builds both bundles from seven arc-tracking resistant cables, typically from EN 2267-010, arranged in a six-around-one configuration. This keeps the test geometry consistent so results can be compared between sleeve designs.
- Defined damage in the protected bundle - Clause 5.3 requires two cables in bundle P to be deliberately damaged at the midpoint before the arc test. This creates the fault condition the sleeve is expected to contain and makes the test relevant to in-service cable damage.
- Controlled electrical setup - Clause 6 requires a three-phase 200/115 VAC 400 Hz star-connected supply, adjustable fault-current settings, circuit breakers matched to the cable size, and measurement of voltage, phase currents, bonding-link currents, and temperature. In practice, the lab has to set up the circuit so the fault level is repeatable and monitored.
- Electrolyte application and test positioning - Clause 6.4 uses a defined electrolyte, delivered at a controlled flow rate onto the damaged area while the specimen is mounted in free air at 10° to the horizontal. This matters because the arc must be initiated in a controlled and repeatable way.
- Test repetition and hazard control - Clause 6.3 requires three specimens for each fault current level, and the procedure requires video recording and shielding of observers. This tells the user that the method is destructive and must be run with strong safety controls.
- Significant short-circuit event criteria - Clause 7.2 treats a test as significant only when arc debris or molten metal is projected, adjacent protected cables are thermally damaged, or line protection trips. For qualification, this means a simple breaker trip alone is not enough to judge performance.
- Post-test examination and dielectric check - Clause 7.3 requires visual inspection, optional microscope examination, and a voltage proof test to EN 3475-302 at 1 000 V on the target conductors that contacted the protection. The practical purpose is to verify that the protected bundle still retains insulation integrity after the arc event.
What terms does SIST EN 6059-502:2027 define?
SIST EN 6059-502:2027 uses several technical terms and abbreviations in the procedure.
- Protection sleeve or conduit - The external protective part being assessed for arc resistance around the cable bundle.
- Target bundle (bundle T) - The bundle used as the unprotected reference side of the setup, made from seven cables.
- Protected bundle (bundle P) - The bundle fitted with the sleeve or conduit under test, including the intentionally damaged cables.
- Prospective fault current - The short-circuit current level set for the test so the arc severity can be controlled and repeated.
- In - The nominal current limit associated with a sleeve or conduit construction, used to match the protection to the intended installation.
- AWG - The cable size notation used in Table 1 to link wire size to circuit-breaker rating and test current.
- PTFE - The tape and tube material used in the bundle lacing and fixture details.
Who uses SIST EN 6059-502:2027?
SIST EN 6059-502:2027 is used by aerospace cable and sleeve manufacturers, test laboratories, qualification engineers, and quality teams responsible for electrical installation hardware. It is also relevant to buyers and product engineers who need to specify or verify protection sleeves and conduits for aircraft wiring bundles. The standard is part of the aerospace electrical cable installation area, so it is most useful where arc damage, bundle protection, and test repeatability matter.
What changed in SIST EN 6059-502:2027 from the previous edition?
SIST EN 6059-502:2027 supersedes EN 6059-502:2014. The stated changes are editorial improvements, an update of the test method to eliminate the 230 VAC electrical arc and retain only the 115 VAC element, added focus on the integrity of the adjacent target harness cable after short-circuit testing, an updated Clause 2 on normative references, and the addition of Clause 3 on terms and definitions.
Which standards are used with SIST EN 6059-502:2027?
SIST EN 6059-502:2027 is used together with several referenced standards:
- EN 6059-100 - general protection sleeve test methods and the common framework for this part.
- EN 6059-501 - the voltage proof test used before the arc test and in the post-test checks.
- EN 3475-302 - the dielectric immersion test used after the short-circuit event on target conductors.
- EN 2350 - circuit breaker technical specification, used for breaker trip characteristics.
- EN 2267-010 - the cable product standard named for the arc-resistant test cables.
- A-A-52083 - the tape lacing and tying specification used for bundle restraint.
What does the SIST EN 6059-502:2027 document contain?
SIST EN 6059-502:2027 contains specimen requirements, bundle preparation instructions, apparatus descriptions, a defined electrolyte delivery system, and a full short-circuit test procedure. It also includes figures for the test configurations and bundle layouts, plus Table 1 for prospective fault currents and breaker ratings. The document finishes with examination steps and a test report list, so the user knows what to record for design qualification, testing, and traceability.
Relations
- Effective Date
- 18-Nov-2026
- Effective Date
- 18-Nov-2026
- Effective Date
- 18-Nov-2026
- Effective Date
- 18-Nov-2026
- Effective Date
- 18-Nov-2026
- Effective Date
- 18-Nov-2026
- Effective Date
- 18-Nov-2026
- Effective Date
- 18-Nov-2026
- Effective Date
- 18-Nov-2026
- Effective Date
- 18-Nov-2026
- Effective Date
- 18-Nov-2026
- Effective Date
- 24-May-2023
Get Certified
Connect with accredited certification bodies for this standard

BUREAU VERITAS Certification Germany
Bureau Veritas certification in Germany.

Element Materials Technology
Materials testing and product certification.

IMQ S.p.A. (Certification)
Italian electrical product certification.
Sponsored listings
Frequently Asked Questions
SIST EN 6059-502:2027 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Aerospace series - Electrical cables, installation - Protection sleeves - Test methods - Part 502: Resistance to electrical arcs". This standard covers: This document specifies a method of assessing the behaviour of protection sleeves or conduits subject to an external electric arc at 115 VAC, 800 Hz. This document is used in conjunction with EN 6059-100. The primary aim of this test is to produce, in a controlled fashion, electric arcs at the immediate vicinity of a protection sleeve or conduit and to examine possible consequences on the protected cables bundle, which supposed to be maintained in a safe condition. These electric arcs are representative of those which may occur in service when a typical adjacent cable bundle is severely damaged and leading to an electrical arc default. In order to optimize thickness and mass of such protection, it is necessary to associate a nominal current limit In to each sleeves or conduits construction. Two levels of prospective fault current are specified for all protection sizes. NOTE This test requires specifics attentions and protections toward operator and personnel applying this test, refer to 6.2 for further details.
This document specifies a method of assessing the behaviour of protection sleeves or conduits subject to an external electric arc at 115 VAC, 800 Hz. This document is used in conjunction with EN 6059-100. The primary aim of this test is to produce, in a controlled fashion, electric arcs at the immediate vicinity of a protection sleeve or conduit and to examine possible consequences on the protected cables bundle, which supposed to be maintained in a safe condition. These electric arcs are representative of those which may occur in service when a typical adjacent cable bundle is severely damaged and leading to an electrical arc default. In order to optimize thickness and mass of such protection, it is necessary to associate a nominal current limit In to each sleeves or conduits construction. Two levels of prospective fault current are specified for all protection sizes. NOTE This test requires specifics attentions and protections toward operator and personnel applying this test, refer to 6.2 for further details.
SIST EN 6059-502:2027 is classified under the following ICS (International Classification for Standards) categories: 29.060.20 - Cables; 49.060 - Aerospace electric equipment and systems. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 6059-502:2027 has the following relationships with other standards: It is inter standard links to SIST EN 6049-008:2014, SIST EN 4674-004:2018, SIST EN 6049-001:2018, SIST EN 6049-005:2015, SIST EN 6049-009:2016, SIST EN 6059-100:2012, SIST EN 4674-003:2017, SIST EN 6049-004:2019, SIST EN 6059-100:2015, SIST EN 6049-008:2018, SIST EN 6049-001:2015, SIST EN 6059-502:2015. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
SIST EN 6059-502:2027 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-januar-2027
Aeronavtika - Električni kabli, namestitev - Zaščitne obojke - Preskusne metode -
502. del: Odpornost proti električnim oblokom
Aerospace series - Electrical cables, installation - Protection sleeves - Test methods -
Part 502: Resistance to electrical arcs
Luft- und Raumfahrt - Elektrische Leitungen, Installation - Schutzschläuche -
Prüfverfahren - Teil 502: Lichtbogenfestigkeit
Série aérospatiale - Câbles électriques, installation - Gaines de protection - Méthodes
d'essais - Partie 502 : Résistance aux arcs électriques
Ta slovenski standard je istoveten z: EN 6059-502:2026
ICS:
29.060.20 Kabli Cables
49.060 Letalska in vesoljska Aerospace electric
električna oprema in sistemi equipment and systems
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EN 6059-502
EUROPEAN STANDARD
NORME EUROPÉENNE
November 2026
EUROPÄISCHE NORM
ICS 49.060 Supersedes EN 6059-502:2014
English Version
Aerospace series - Electrical cables, installation -
Protection sleeves - Test methods - Part 502: Resistance to
electrical arcs
Série aérospatiale - Câbles électriques, installation - Luft- und Raumfahrt - Elektrische Leitungen,
Gaines de protection - Méthodes d'essais - Partie 502 : Installation - Schutzschläuche - Prüfverfahren - Teil
Résistance aux arcs électriques 502: Lichtbogenfestigkeit
This European Standard was approved by CEN on 04 October 2026.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN
member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by
translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark,
Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands,
Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye
and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
C O M I T É E U R O P É E N D E N O R M A L I S A T I O N
E U R O P Ä I S C H E S K O M I T E E F Ü R N O R M U N G
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2026 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 6059-502:2026 E
worldwide for CEN national Members.
Contents Page
European foreword . 3
1 Scope . 4
2 Normative references . 4
3 Terms and definitions . 4
4 Specimen requirements . 4
5 Definition and preparation of specimens . 5
5.1 Test configuration . 5
5.2 Protected bundle . 6
5.2.1 Definition and constitution . 6
5.2.2 Preparation . 6
5.2.3 Configuration of the assembly of cables . 6
5.3 Aggressor bundle (bundle unprotected) . 7
5.3.1 Definition and constitution . 7
5.3.2 Preparation . 7
5.3.3 Lay up the seven cables as follows . 7
6 Apparatus . 8
6.1 Test configurations: case of a three-phase 115 VAC 800 Hz network . 8
6.2 Test equipment requirements . 11
6.3 Test protocol . 11
6.4 Test rig set-up . 12
6.5 Description of the expected measurements. 12
7 Method . 13
7.1 Test procedure . 13
7.2 Short circuit pass/fail criteria . 13
7.3 Examination . 14
7.4 Test report . 14
8 Requirements . 15
Bibliography . 16
European foreword
This document (EN 6059-502:2026) has been prepared by ASD-STAN.
After enquiries and votes carried out in accordance with the rules of this Association, this document has
received the approval of the National Associations and the Official Services of the member countries of
ASD-STAN, prior to its presentation to CEN.
This document shall be given the status of a national standard, either by publication of an identical text
or by endorsement, at the latest by May 2027, and conflicting national standards shall be withdrawn at
the latest by May 2027.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN shall not be held responsible for identifying any or all such patent rights.
This document supersedes EN 6059-502:2014.
EN 6059-502:2014:
— update of test method to eliminate the 230 VAC electrical arc, retain only the 115 VAC element and
to ensure integrity of adjacent target harness cable protected with sleeve or conduit after short
circuit test;
— update of Clause 2 “Normative references”;
— addition of Clause 3 “Terms and definitions”;
— modification of frequency from 400 Hz to 800 Hz;
— update of the set up.
According to the CEN-CENELEC Internal Regulations, the national standards organizations of the
following countries are bound to implement this document: Austria, Belgium, Bulgaria, Croatia, Cyprus,
Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Republic of North
Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and the
United Kingdom.
1 Scope
This document specifies a method of assessing the behaviour of protection sleeves or conduits subject
to an external electric arc at 115 VAC, 800 Hz.
This document is used in conjunction with EN 6059-100.
The primary aim of this test is to produce, in a controlled fashion, electric arcs at the immediate vicinity
of a protection sleeve or conduit and to examine possible consequences on the protected cables bundle,
which is supposed to be maintained in a safe condition.
These electric arcs are representative of those which can occur in service when a typical adjacent cable
bundle is severely damaged and leading to an electrical arc default.
In order to optimize thickness and mass of such protection, it is necessary to associate a nominal
current limit I to each sleeves or conduits construction.
n
Two levels of prospective fault current are specified for all protection sizes.
NOTE This test requires specific attentions and protections toward operator and personnel applying this test,
refer to 6.2 for further details.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
EN 2350, Aerospace series — Circuit breakers — Technical specification
EN 3475-302, Aerospace series — Cables, electrical, aircraft use — Test methods — Part 302: Voltage
proof test
EN 6059-501, Aerospace series — Electrical cables, installation — Protection sleeves — Test methods —
Part 501: Voltage proof test
A-A-52083, Tape, Lacing and Tying, Glass
3 Terms and definitions
No terms and definitions are listed in this document.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at https://www.iso.org/obp
— IEC Electropedia: available at https://www.electropedia.org/
4 Specimen requirements
Protection sleeves or conduits to be tested shall be of traceable origin and, unless otherwise specified,
shall have passed the voltage proof test (according to EN 6059-501) as specified in the concerned
product standard.
Published by Department of Defense (DoD), available at: https://assist.dla.mil/online/start/.
Unless otherwise specified in the concerned product standard, at least one size per thickness and/or
construction design (if requirement, design, process or material are different from one size to another)
shall be assessed.
If possible, for each thickness or construction type, the test shall be performed on a sample having the
minimum authorized thickness or minimum authorized mass.
5 Definition and preparation of specimens
5.1 Test configuration
Test set up is made to reproduce electrical arc default to demonstrate that sleeve/conduit protect
against arc blast and act also as a physical barrier. The nominal current (I ) for short circuit shall be
n
based on 15 A which represents sleeve installation and signal segregation at aircraft integration.
The protected bundle shall be attached side by side on the aggressor bundle with qualified ties,
according to the Figure 1 and illustrated by Figure 3.
Key
1 Cable tie 5 Aggressive bundle (refer to 5.3 for bundle configuration)
2 Protection sleeve 6 Protected bundle (refer to 5.2 for bundle configuration)
3 Camera 7 d = 0 mm
4 Support 8 Damage/cut on cable for electrical arc ignition
Figure 1 — Test configuration
5.2 Protected bundle
5.2.1 Definition and constitution
The protected bundle shall be equipped with an external sleeve or conduit protection for arc resistance
performance and protection.
The protected bundle shall be made of minimum number of cables to ensure the maximum full filling
ratio of the sleeve or conduit by using aluminium wire AWG 24 size (typically from EN 4681-003
product standard, or equivalent, unless otherwise specified in the concerned protection sleeves or
conduits product standard).
5.2.2 Preparation
To form the bundle, cut separate lengths of 1 m consecutively from one length of cable, and strip one of
the ends of insulation to permit electrical connection.
Clean each length of cable with a clean cloth moistened with propan-2-ol (isopropyl alcohol) fluid.
5.2.3 Configuration of the assembly of cables
a) Form the bundle of cables.
b) Ensure that all cables are straight and geometrically parallel and restrained by cable ties such that
they are in continuous contact at least within the test zone.
c) Position the ties at 50 mm spacing toward the end of the specimen.
The tie material shall be PTFE glass lacing tape conforming to A-A-52083, finish D size 3.
d) The cable bundle outer diameter shall be as close as possible to the maximum acceptable internal
diameter of the protection sleeve to be tested.
e) Then, the bundle shall be placed inside 300 mm of the suitable protection sleeve. Place the middle
protection sleeve or conduit length in front of three damaged cables from aggressor bundle.
f) Cable ties over the protection shall be installed as described in Figure 1 and shall respect the
installation specificities of each protection sleeve or conduit when applicable.
For open protection sleeves with an overlapping, the overlap shall not be placed in front of the short
circuit area according to Figure 2.
-----------
...