SIST EN 61303:1995
(Main)Medical electrical equipment - Radionuclide calibrators - Particular methods for describing performance
Medical electrical equipment - Radionuclide calibrators - Particular methods for describing performance
Covers radionuclide calibrators of the well type, with a gas-filled ionization chamber as used in the practice of nuclear medicine. The object of this Standard is to identify the most important characteristics of radionuclide calibrators and lay down associated test methods to enable manufacturers to declare the characteristics of their devices in a standardized way and facilitate comparisons between devices.
Medizinische elektrische Geräte - Aktivimeter - Spezielle Verfahren zur Bestimmung der Leistungsparameter
Appareils électromédicaux - Calibrateurs de radionucléides - Méthodes particulières pour décrire les performances
Concerne les calibrateurs de radionucléides à chambre d'ionisation remplie de gaz, de type puits, utilisés dans la pratique de la médecine nucléaire. L'objet de cette norme est d'identifier les caractéristiques les plus importantes des calibrateurs de radionucléides et de spécifier les méthodes de test associées pour permettre aux fabricants de décrire les caractéristiques de leurs appareils de façon normalisée pour faciliter les comparaisons entre les appareils.
Medical electrical equipment - Radionuclide calibrators - Particular methods for describing performance (IEC 1303:1994)
Zajema jaškaste radionuklidne kalibratorje z ionizacijsko komoro, napolnjeno s plinom, kot se uporabljajo v nuklearni medicini. Cilj tega standarda je prepoznati najpomembnejše značilnosti radionuklidnih kalibratorjev in določiti povezane preskusne metode, da se proizvajalcem omogočijo standardizirani način navedbe lastnosti njihovih pripomočkov in lažje primerjave med pripomočki.
General Information
Relations
Overview
EN 61303:1995 - Medical electrical equipment: Radionuclide calibrators - Particular methods for describing performance (identical to IEC 1303:1994) defines standardized methods to describe and test the performance of well-type radionuclide calibrators that use a gas-filled ionization chamber, as used in nuclear medicine. The standard’s objective is to identify the most important performance characteristics and specify associated test methods so manufacturers can declare device characteristics consistently and users can compare products reliably.
Key topics
- Scope and device type: Applies specifically to well-type radionuclide calibrators with gas-filled ionization chambers used for activity measurements in nuclear medicine.
- Performance characteristics: Defines the principal characteristics to be reported (for example: accuracy, precision, reproducibility, linearity, energy dependence, background response, geometry or positioning effects, and dead-time behavior) - enabling consistent manufacturer declarations.
- Test methods: Specifies standardized measurement procedures and conditions for evaluating those characteristics so results are comparable between devices and laboratories.
- Measurement conditions and reporting: Requires clear description of test geometries, source types, measurement intervals and conditions under which performance data are determined.
- Uncertainty and comparability: Encourages reporting measurement uncertainty and using standardized metrics to support meaningful comparisons between calibrators.
Applications
- Manufacturers use the standard to develop test procedures and to prepare standardized performance specifications and declarations for product datasheets.
- Medical physicists and clinical engineers use it for device acceptance testing, commissioning, periodic quality assurance, and to interpret manufacturers’ performance claims.
- Hospitals and nuclear medicine departments rely on standardized performance data when procuring radionuclide calibrators to ensure compatibility with clinical measurement needs.
- Test laboratories and regulators apply the methods to verify compliance and to perform inter-laboratory comparisons.
Who benefits
- Manufacturers, clinical engineers, medical physicists, hospital procurement teams, conformity assessment bodies, and radiation safety officers seeking clear, comparable performance information for well-type radionuclide calibrators.
Related standards
- EN 61303:1995 is identical to IEC 1303:1994 (as referenced). Users should consult national or regional implementations and adjacent standards on electrical safety, metrology, and quality assurance in nuclear medicine for complementary requirements.
Keywords: radionuclide calibrators, well-type ionization chamber, nuclear medicine, performance description, test methods, calibration, EN 61303, IEC 1303, measurement uncertainty, device comparability.
Frequently Asked Questions
SIST EN 61303:1995 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Medical electrical equipment - Radionuclide calibrators - Particular methods for describing performance". This standard covers: Covers radionuclide calibrators of the well type, with a gas-filled ionization chamber as used in the practice of nuclear medicine. The object of this Standard is to identify the most important characteristics of radionuclide calibrators and lay down associated test methods to enable manufacturers to declare the characteristics of their devices in a standardized way and facilitate comparisons between devices.
Covers radionuclide calibrators of the well type, with a gas-filled ionization chamber as used in the practice of nuclear medicine. The object of this Standard is to identify the most important characteristics of radionuclide calibrators and lay down associated test methods to enable manufacturers to declare the characteristics of their devices in a standardized way and facilitate comparisons between devices.
SIST EN 61303:1995 is classified under the following ICS (International Classification for Standards) categories: 11.040.50 - Radiographic equipment. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 61303:1995 has the following relationships with other standards: It is inter standard links to SIST EN 61303:1995/AC:2016. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
You can purchase SIST EN 61303:1995 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of SIST standards.
Standards Content (Sample)
SLOVENSKI STANDARD
01-maj-1995
Medical electrical equipment - Radionuclide calibrators - Particular methods for
describing performance (IEC 1303:1994)
Medical electrical equipment - Radionuclide calibrators - Particular methods for
describing performance
Medizinische elektrische Geräte - Aktivimeter - Spezielle Verfahren zur Bestimmung der
Leistungsparameter
Appareils électromédicaux - Calibrateurs de radionucléides - Méthodes particulières pour
décrire les performances
Ta slovenski standard je istoveten z: EN 61303:1995
ICS:
11.040.50 Radiografska oprema Radiographic equipment
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
S
...
記事のタイトル:SIST EN 61303:1995 - 医療電気機器 - 放射性核種キャリブレーター - 性能の説明のための特定の方法 記事の内容:この記事では、核医学の実践で使用されるガス充填イオン化チャンバーを備えたウェル型の放射性核種キャリブレーターについて、SIST EN 61303:1995規格について説明しています。この規格の目的は、放射性核種キャリブレーターの最も重要な特性を特定し、メーカーがそのデバイスの特性を標準化された方法で宣言し、デバイス間の比較を容易にするための関連するテスト方法を提供することです。
기사 제목 : SIST EN 61303:1995 - 의료 전기 장비 - 방사성 동위원소 분류자 - 성능 설명을 위한 특정 방법 기사 내용: 본 기사는 핵의학 분야에서 사용되는 가스 채워진 이온화 챔버를 가진 웰 타입의 방사성 동위원소 분류자에 대한 SIST EN 61303:1995 표준에 대해 다루고 있다. 이 표준의 목적은 방사성 동위원소 분류자의 가장 중요한 특성을 식별하고, 제조업체가 그들의 장치의 특성을 표준화된 방식으로 선언하고 장치간의 비교를 용이하게 하기 위한 관련 테스트 방법을 제시하는 것이다.
The article discusses the SIST EN 61303:1995 standard on radionuclide calibrators used in nuclear medicine. Specifically, the standard focuses on well-type calibrators with gas-filled ionization chambers. Its objective is to outline the key features of these calibrators and provide test methods for manufacturers to declare their devices' characteristics in a standardized manner. This standard aims to facilitate comparisons between different radionuclide calibrators.








Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...