Plastics piping systems for non-pressure underground drainage and sewerage - Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) - Part 2: Specifications for pipes and fittings with smooth internal and external surface and the system, Type A

This part of EN 13476, together with EN 13476-1, specifies the definitions and requirements for pipes, fittings and the system based on unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) structured-wall piping systems that are intended to be used for non-pressure underground drainage and sewerage systems.
This part is applicable to pipes and fittings with smooth internal and external surfaces, designated as Type A.
It specifies test methods and test parameters as well as requirements.
This part is applicable to:
a)   structured-wall pipes and fittings, which are intended to be used buried underground outside the building structure; reflected in the marking of products by “U”;
b)   structured-wall pipes and fittings, which are intended to be used buried underground both outside (application area code “U”) and within the building structure (application area code “D”); reflected in the marking of products by “UD”.
This part is applicable to structured-wall pipes and fittings with or without an integral socket with elastomeric ring seal joints as well as welded and fused joints.
This part is intended to be read in conjunction with part 1 of this standard
This part covers a range of pipe and fitting sizes, materials, pipe constructions, stiffness classes, application classes, and tolerance classes and gives recommendations concerning colours.
NOTE 1   It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes.
NOTE 2   For dimensions larger than DN 1200 OD/ID this document may be applied regarding appearance, colour, physical and mechanical characteristics as well as performance requirements.

Kunststoff-Rohrleitungssysteme für erdverlegte drucklose Abwasserkanäle und -leitungen - Rohrleitungssysteme mit profilierter Wandung aus weichmacherfreiem Polyvinylchlorid (PVC-U), Polypropylen (PP) und Polyethylen (PE) - Teil 2: Anforderungen an Rohre und Formstücke mit glatter Innen- und Außenfläche und an das Rohrleitnungssystem, Rohrtyp A

Dieser Teil von EN 13476 legt gemeinsam mit EN 13476-1 die Definitionen und Anforderungen für Rohre, Formstücke und das Rohrleitungssystem aus weichmacherfreiem Polyvinylchlorid (PVC-U), Polypropylen (PP) und Polyethylen (PE) mit profilierter Wandung fest, die für erdverlegte, drucklos betriebene Abwasserkanäle und -leitungen verwendet werden.
Dieser Teil gilt für Rohre und Formstücke mit glatten Innen- und Außenflächen, bezeichnet als Typ A.
Es werden sowohl Prüfverfahren und Prüfparameter als auch Anforderungen festgelegt.
Dieser Teil gilt für:
a)   Rohre und Formstücke mit profilierter Wandung, die ausschließlich für erdverlegte Anwendungen außer¬halb einer Gebäudestruktur vorgesehen sind; gekennzeichnet mit Anwendungs¬kennzeichen „U“;
b)   Rohre und Formstücke mit profilierter Wandung, die sowohl für erdverlegte Anwendungen außerhalb der Gebäudestruktur (Anwendungskennzeichen „U“) als auch innerhalb einer Gebäudestruktur (Anwen¬dungs¬kennzeichen „D“) vorgesehen sind; gekennzeichnet mit Anwendungs¬kennzeichen UD.
Dieser Teil gilt für Rohre und Formstücke mit profilierter Wandung sowohl mit glatten Enden als auch mit angeformter Muffe, die mittels elastomerer Dichtringverbindungen bzw. durch Heizelement-Stumpf-, Extrusions- oder Heizwendelschweißen miteinander verbunden sind.
Diese Norm enthält Festlegungen für Maße von Rohren und Formstücken, für Werkstoffe, Rohrkonstruktionen, für Steifigkeitsklassen, Anwendungs- und Toleranzklassen und gibt Empfehlungen für die Einfärbung.
ANMERKUNG 1   Der Anwender bzw. Auftraggeber ist unter Berücksichtigung der eigenen Anforderungen sowie der geltenden nationalen Festlegungen und Verlegepraktiken oder -vorschriften für die entsprechende Auswahl dieser Kriterien verantwortlich.
ANMERKUNG 2   Für Durchmesser größer DN 1 200 OD/ID kann dieses Dokument für Beschaffenheit, Farbe, physikalische und mechanische Eigenschaften sowie Anforderungen an die Gebrauchs¬tauglichkeit angewendet werden.

Systemes de canalisations en plastiques pour les branchements et les collecteurs d'assainissement sans pression enterrés - Systemes de canalisations a parois structurées en poly(chlorure de vinyle) non plastifié (PVC-U), polypropylene (PE) - Partie 2: Spécifications pour les tubes et raccords avec une surface interne et externe lisse et le systeme, de Type A

La présente partie de l'EN 13476, conjointement avec l’EN 13476-1, spécifie les définitions et les exigences pour les tubes, les raccords et le système de canalisations fabriqués à partir de poly(chlorure de vinyle) non plastifié (PVC-U), polypropylène (PP) et polyéthylène (PE), destinés à être utilisés en tant que systèmes de canalisations à parois structurées dans le domaine des branchements et des collecteurs d'assainissement enterrés sans pression.
La présente partie s'applique aux tubes et raccords avec une surface interne et externe lisse, désignés de Type A.
Elle spécifie les méthodes d'essai et les paramètres d'essai ainsi que les exigences.
La présente partie s'applique aux :
a)   tubes et raccords à parois structurées, destinés à être utilisés enterrés à l'extérieur du bâtiment ; ce qui est reflété par le marquage des produits par « U » ;
b)   tubes et raccords à parois structurées, destinés à être utilisés enterrés, aussi bien à l'extérieur (code de la zone d’application « U ») de la structure des bâtiments, qu’à l'intérieur (code de la zone d’application « D ») ; ce qui est reflété par le marquage des produits par « UD ».
La présente partie s'applique aux tubes et raccords à parois structurées qui comprennent des assemblages à bague d'étanchéité en élastomère avec ou sans emboîture intégrée ainsi que des assemblages soudés et les assemblages obtenus par fusion.
La présente partie couvre une gamme de dimensions de tubes et de raccords, de matières, de constructions de tube, de classes de rigidité, de classes d'application et de classes de tolérance et donne des recommandations concernant les couleurs.
NOTE 1   Il est de la responsabilité de l'acheteur ou du prescripteur de faire les sélections appropriées à partir de ces aspects, en tenant compte des exigences particulières et des règles nationales concernées et des pratiques ou codes de pose.
NOTE 2   Pour les dimensions plus grandes que DN 1200 OD/ID, le présent document peut être appliqué en ce qui co

Cevni sistemi iz polimernih materialov za odvodnjavanje in kanalizacijo, ki delujejo po težnostnem principu in so položeni v zemljo - Cevni sistemi s strukturirano steno iz nemehčanega polivinilklorida (PVC-U), polipropilena (PP) in polietilena (PE) - 2. del: Specifikacije za cevi in fitinge z gladko notranjo in zunanjo površino in sistem, tip A

General Information

Status
Withdrawn
Publication Date
02-Jul-2007
Withdrawal Date
16-May-2018
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
17-May-2018
Due Date
09-Jun-2018
Completion Date
17-May-2018

Relations

Buy Standard

Standard
EN 13476-2:2007
English language
44 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Plastics piping systems for non-pressure underground drainage and sewerage - Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) - Part 2: Specifications for pipes and fittings with smooth internal and external surface and the system, Type ASystemes de canalisations en plastiques pour les branchements et les collecteurs d'assainissement sans pression enterrés - Systemes de canalisations a parois structurées en poly(chlorure de vinyle) non plastifié (PVC-U), polypropylene (PE) - Partie 2: Spécifications pour les tubes et raccords avec une surface interne et externe lisse et le systeme, de Type AKunststoff-Rohrleitungssysteme für erdverlegte drucklose Abwasserkanäle und -leitungen - Rohrleitungssysteme mit profilierter Wandung aus weichmacherfreiem Polyvinylchlorid (PVC-U), Polypropylen (PP) und Polyethylen (PE) - Teil 2: Anforderungen an Rohre und Formstücke mit glatter Innen- und Außenfläche und an das Rohrleitnungssystem, Rohrtyp ATa slovenski standard je istoveten z:EN 13476-2:2007SIST EN 13476-2:2007en;fr;de93.030Zunanji sistemi za odpadno vodoExternal sewage systems23.040.20Cevi iz polimernih materialovPlastics pipesICS:SLOVENSKI
STANDARDSIST EN 13476-2:200701-julij-2007







EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 13476-2May 2007ICS 93.030 English VersionPlastics piping systems for non-pressure underground drainageand sewerage - Structured-wall piping systems of unplasticizedpoly(vinyl chloride) (PVC-U), polypropylene (PP) andpolyethylene (PE) - Part 2: Specifications for pipes and fittingswith smooth internal and external surface and the system, TypeASystèmes de canalisations en plastiques pour lesbranchements et les collecteurs d'assainissement sanspression enterrés - Systèmes de canalisations à paroisstructurées en poly(chlorure de vinyle) non plastifié (PVC-U), polypropylène (PE) - Partie 2: Spécifications pour lestubes et raccords avec une surface interne et externe lisseet le système, de Type AKunststoff-Rohrleitungssysteme für erdverlegte druckloseAbwasserkanäle und -leitungen - Rohrleitungssysteme mitprofilierter Wandung aus weichmacherfreiemPolyvinylchlorid (PVC-U), Polypropylen (PP) undPolyethylen (PE) - Teil 2: Anforderungen an Rohre undFormstücke mit glatter Innen- und Außenfläche und an dasRohrleitnungssystem, Rohrtyp AThis European Standard was approved by CEN on 5 March 2007.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2007 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 13476-2:2007: E



EN 13476-2:2007 (E) 2 Contents Page Foreword.4 Introduction.5 1 Scope.6 2 Normative references.6 3 Terms, definitions, symbols and abbreviations.8 3.1 Symbols.8 3.2 Abbreviations.9 4 Material.10 4.1 General.10 4.2 Unplasticized poly(vinyl chloride) (PVC-U).10 4.3 Polypropylene (PP).11 4.4 Polyethylene (PE).12 4.5 Sealing rings.14 4.6 Fused or welded joints.14 4.7 Adhesives for PVC-U.14 5 Designation of wall constructions and examples of typical jointing methods.15 5.1 General.15 5.2 Wall constructions designated as Type A.15 5.3 Designation and design of joints.16 6 Appearance and colour.16 7 Geometrical characteristics.16 7.1 General.16 7.2 Dimensions.16 7.3 Types of fittings.22 7.4 Design length of fittings.22 8 Physical characteristics.22 8.1 Unplasticized poly(vinyl chloride) (PVC-U).22 8.2 Polypropylene (PP).23 8.3 Polyethylene (PE).24 9 Mechanical characteristics.25 9.1 Mechanical characteristics of pipes.25 9.2 Mechanical characteristics of fittings.27 10 Performance Requirements.28 11 Marking.30 11.1 General.30 11.2 Minimum required marking.30 11.3 Additional marking.31 Annex A (normative)
Virgin PVC-U material.32 Annex B (normative)
Utilisation of non-virgin PVC-U material.33 B.1 Reprocessable and recyclable material from pipes and fittings.33 B.2 External reprocessable and recyclable materials with agreed specifications.33 B.3 External reprocessable and recyclable materials not covered by an agreed specification.34 Annex C (normative)
Virgin PP material.36



EN 13476-2:2007 (E) 3 Annex D (normative)
Utilisation of non-virgin PP material.37 D.1 Reprocessable and recyclable material from pipes and fittings.37 D.2 External reprocessable and recyclable materials with an agreed specification.37 D.3 External reprocessable and recyclable materials not covered by an agreed specification.37 Annex E (normative)
Virgin PE material.38 Annex F (normative)
Utilisation of non-virgin PE material.39 F.1 Reprocessable and recyclable material from pipes and fittings.39 F.2 External reprocessable and recyclable materials with an agreed specification.39 F.3 External reprocessable and recyclable materials not covered by an agreed specification.39 F.4 External reprocessable and recyclable material from PE rotational-moulded fittings and other components.40 Annex G (normative)
Impact test at 23 °C.41 Annex H (normative)
Impact test at −−−− 10 °C.42 Annex I (normative)
Ring flexibility test at 20 % diametric deflection.43 Annex J (informative)
Survey of possible use of reprocessable and recyclable material.44



EN 13476-2:2007 (E) 4 Foreword This document (EN 13476-2:2007) has been prepared by Technical Committee CEN/TC 155 “Plastics piping systems and ducting systems”, the secretariat of which is held by NEN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by November 2007, and conflicting national standards shall be withdrawn at the latest by November 2007. This standard is a part of a System Standard for plastics piping systems of particular materials for a specified application. There are a number of such System Standards. System Standards are based on the results of the work being undertaken in ISO/TC 138 “Plastics pipes, fittings and valves for the transport of fluids”, which is a Technical Committee of the International Organization for Standardization (ISO). They are supported by separate standards on test methods to which references are made throughout the System Standard. The System Standards are consistent with general standards on functional requirements and on recommended practice for installation. EN 13476 consists of the following Parts under the general title Plastics piping systems for non-pressure underground drainage and sewerage — Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) — Part 1: General requirements and performance characteristics;
— Part 2: Specifications for pipes and fittings with smooth internal and external surface and the system, Type A (this standard); — Part 3: Specifications for pipes and fittings with a smooth internal surface and profiled external surface and the system, Type B; — Part 4: Assessment of conformity (CEN/TS); — Part 5: Guidance for installation (CEN/TS).1 For pipes and fittings which have conformed to the relevant national standard before May 2007, as shown by the manufacturer or by a certification body, the national standard may continue to be applied until May 2009.
National standards specifically for pipes and fittings for the transport of surface water are not considered to be conflicting with this standard and may thus be allowed to coexist. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
1 The feasibility of this project is under study.



EN 13476-2:2007 (E) 5 Introduction This standard provides optional choices for impact resistance (see Annex G and Annex H) and ring flexibility, see Annex I. As appropriate, the individual countries may select between those options in their national forewords.



EN 13476-2:2007 (E) 6 1 Scope This part of EN 13476, together with EN 13476-1, specifies the definitions and requirements for pipes, fittings and the system based on unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) structured-wall piping systems that are intended to be used for non-pressure underground drainage and sewerage systems.
This part is applicable to pipes and fittings with smooth internal and external surfaces, designated as Type A.
It specifies test methods and test parameters as well as requirements.
This part is applicable to: a) structured-wall pipes and fittings, which are intended to be used buried underground outside the building structure; reflected in the marking of products by “U”; b) structured-wall pipes and fittings, which are intended to be used buried underground both outside (application area code “U”) and within the building structure (application area code “D”); reflected in the marking of products by “UD”. This part is applicable to structured-wall pipes and fittings with or without an integral socket with elastomeric ring seal joints as well as welded and fused joints. This part covers a range of pipe and fitting sizes, materials, pipe constructions, stiffness classes, application classes, and tolerance classes and gives recommendations concerning colours. NOTE 1 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes.
NOTE 2 For dimensions larger than DN 1200 OD/ID this document may be applied regarding appearance, colour, physical and mechanical characteristics as well as performance requirements. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 476, General requirements for components used in discharge pipes, drains and sewers for gravity systems EN 580, Plastics piping systems  Unplasticized poly(vinyl chloride) (PVC-U) pipes  Test method for the resistance to dichloromethane at a specified temperature (DCMT) EN 681-1, Elastomeric seals  Materials requirements for pipe joint seals used in water and drainage applications  Part 1: Vulcanized rubber EN 681-2, Elastomeric seals  Materials requirements for pipe joint seals used in water and drainage applications  Part 2: Thermoplastic elastomers EN 681-4, Elastomeric seals  Materials requirements for pipe joint seals used in water and drainage applications  Part 4: Cast polyurethane sealing elements EN 727, Plastics piping and ducting systems  Thermoplastics pipes and fittings  Determination of Vicat softening temperature (VST) EN 728, Plastics piping and ducting systems  Polyolefin pipes and fittings  Determination of oxidation induction time



EN 13476-2:2007 (E) 7 EN 744, Plastics piping and ducting systems  Thermoplastics pipes  Test method for resistance to external blows by the round-the-clock method EN 922, Plastics piping and ducting systems  Pipes and fittings of unplasticized poly(vinyl chloride) (PVC-U)  Specimen preparation for determination of the viscosity number and calculation of the K-value EN 1053, Plastics piping systems  Thermoplastics piping systems for non-pressure applications  Test method for watertightness EN 1055:1996, Plastics piping systems  Thermoplastics piping systems for soil and waste discharge inside buildings  Test method for resistance to elevated temperature cycling EN 1277, Plastics piping systems  Thermoplastics piping systems for buried non-pressure applications  Test methods for leaktightness of elastomeric sealing ring type joints EN 1401-1, Plastics piping systems for non-pressure underground drainage and sewerage  Unplasticized poly(vinyl chloride) (PVC-U)  Part 1: Specifications for pipes, fittings and the system EN 1411, Plastics piping and ducting systems  Thermoplastics pipes  Determination of resistance to external blows by the staircase method EN 1437, Plastics piping systems  Piping systems for underground drainage and sewerage  Test method for resistance to combined temperature cycling and external loading EN 1446, Plastics piping and ducting systems  Thermoplastics pipes  Determination of ring flexibility EN 1852-1, Plastics piping systems for non-pressure underground drainage and sewerage  Polypropylene (PP)  Part 1: Specifications for pipes, fittings and the system EN 1905, Plastics piping systems  Unplasticized poly(vinyl chloride) (PVC-U) pipes, fittings and material — Method for assessment of the PVC content based on total chlorine content EN 1979, Plastics piping and ducting systems  Thermoplastics spirally-formed structured-wall pipes  Determination of the tensile strength of a seam EN 12061, Plastics piping systems — Thermoplastics fittings — Test method for impact resistance EN 12256, Plastics piping systems — Thermoplastics fittings — Test method for mechanical strength or flexibility of fabricated fittings EN 12666-1, Plastics piping systems for non-pressure underground drainage and sewerage  Polyethylene (PE)  Part 1: Specifications for pipes, fittings and the system EN 13476-1:2007, Plastics piping systems for non-pressure underground drainage and sewerage  Structured-wall piping systems of unplasticized poly(vinyl chloride)
(PVC-U), polypropylene (PP) and polyethylene (PE)  Part 1: General requirements and performance characteristics EN 13476-3, Plastics piping systems for non-pressure underground drainage and sewerage  Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE)  Part 3: Specifications for pipes and fittings with smooth internal and profiled external surface and the system, Type B CEN/TS 14541:2007, Plastics pipes and fittings for non-pressure applications  Utilisation of non-virgin PVC-U, PP and PE materials EN 14741, Thermoplastics piping and ducting systems  Joints for buried non-pressure applications  Test method for the long-term sealing performance of joints with elastomeric seals by estimating the sealing pressure



EN 13476-2:2007 (E) 8 EN 14758-1, Plastics piping systems for non-pressure underground drainage and sewerage  Polypropylene with mineral modifiers (PP-MD)  Part 1: Specifications for pipes, fittings and the system EN ISO 580, Plastics piping and ducting systems  Injection-moulded thermoplastics fittings  Methods for visually assessing the effects of heating (ISO 580:2005) EN ISO 1133:2005, Plastics  Determination of the melt mass-flow rate (MFR) and the melt volume-flow rate (MVR) of thermoplastics (ISO 1133:2005) EN ISO 1167-1, Thermoplastics pipes, fittings and assemblies for the conveyance of fluids  Determination of the resistance to internal pressure  Part 1: General method (ISO 1167-1:2006) EN ISO 1167-2, Thermoplastics pipes, fittings and assemblies for the conveyance of fluids  Determination of the resistance to internal pressure  Part 2: Preparation of pipe test pieces (ISO 1167-2:2006) EN ISO 1183-1, Plastics  Methods for determining the density of non-cellular plastics  Part 1: Immersion method, liquid pyknometer and titration method (ISO 1183-1:2004) EN ISO 2505, Thermoplastics pipes  Longitudinal reversion  Test method and parameters (ISO 2505:2005) EN ISO 3126, Plastics piping systems  Plastics piping components  Determination of dimensions (ISO 3126:2005) EN ISO 3451-1, Plastics- Determination of ash  Part 1: General methods (ISO 3451-1:1997) EN ISO 9967, Plastics pipes  Determination of creep ratio (ISO 9967:1994) EN ISO 9969, Thermoplastics pipes  Determination of ring stiffness (ISO 9969:1994) ISO 13967, Thermoplastics fittings — Determination of ring stiffness
3 Terms, definitions, symbols and abbreviations For the purposes of this document, the terms and definitions given in EN 13476-1:2007 apply. 3.1 Symbols A length of engagement, or maximum pull-out whilst maintaining tightness C length of the sealing zone de outside diameter dem mean outside diameter dim mean inside diameter dn nominal diameter dsm,min minimum mean inside diameter of socket e wall thickness (at any point) ec construction height emin minimum wall thickness of pipe or spigot e2 wall thickness at any point of the cylindrical part of a socket



EN 13476-2:2007 (E) 9 e3 wall thickness at any point of a sealing ring groove of a socket e4 wall thickness of the inside layer (waterway wall thickness) e5 wall thickness of the inside layer under a hollow section l effective length of a pipe L1,min minimum length of a spigot
IMP 23C impact resistance determined at +23 °C 7 impact resistance determined at −10 °C 3.2 Abbreviations CaCO3 calcium carbonate CT close tolerance DN nominal size DN/ID nominal size related to inside diameter DN/OD nominal size related to outside diameter H50 value for impact resistance of a pipe MgCO3 magnesium carbonate Mg3Si4O10(OH)2 magnesiumsilicate, talcum MFR melt mass-flow rate OIT oxidation induction time PE polyethylene PP polypropylene PP-MD mineral modified PP PVC-U unplasticized poly(vinyl chloride) RF ring flexibility performance S pipe series S SDR standard dimension ratio SN ring stiffness class



EN 13476-2:2007 (E) 10 TIR true impact rate TPE thermo plastic elastomer VST Vicat softening temperature 4 Material 4.1 General The material shall be one of the following: unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) or polyethylene (PE), to which are added additives needed to facilitate the manufacture of components conforming to this document, including the relevant annexes. 4.2 Unplasticized poly(vinyl chloride) (PVC-U) 4.2.1 General The raw material shall be PVC-U to which are added additives needed to facilitate the manufacture of components conforming to the requirements of this document (see also Annex A). NOTE Additional information on the characteristics of PVC-U material or components is given in Annex A of EN 13476-1:2007. 4.2.2 Pipe and fitting material characteristics When tested in accordance with the test method as specified in Table 1 using the indicated parameters, the material shall have characteristics conforming to the requirements given in Table 1. Table 1 — Material characteristics of PVC-U pipes and injection-moulded fittings Characteristic Requirements Test parameters Test method Resistance to internal pressure a b c
No failure during the test period End caps Orientation Number of test pieces Test temperature Circumferential stress
- pipe material
- fitting material Conditioning period
Type of test Test period Type A or Type B
Free 3 60 °C
10 MPa
6,3 MPa
Shall conform to
EN ISO 1167-1 Water-in-water 1 000 h EN ISO 1167-1 and EN ISO 1167-2 a This requirement does not apply to the specified intermediate layer of a Type A1 pipe. b For the extrusion compounds for the internal and external layers of a multilayer pipe, this test shall be carried out in the form of a solid wall pipe made from the relevant material(s). c For injection-moulding compounds, this test shall be carried out in the form of an injection-moulded or extruded sample in solid wall pipe form made from the relevant material.
4.2.3 Utilisation of non-virgin materials For the utilisation of non-virgin PVC-U materials, conditions and requirements are given in Annex B. NOTE Annex J offers a survey of the possible use of reprocessable and recyclable materials.



EN 13476-2:2007 (E) 11 4.3 Polypropylene (PP) 4.3.1 General The compound for pipes and fittings shall be PP based material to which are added additives needed to facilitate the manufacture of components conforming to the requirements of this document. See also Annex C. NOTE Additional information of the characteristics of PP material or components made thereof is given in Annex A of EN 13476-1:2007. 4.3.2 Pipe and fitting material characteristics When tested in accordance with the test methods as specified in Table 2 using the indicated parameters, the material shall have characteristics conforming to the requirements given in Table 2. Table 2 — Material characteristics of PP pipes and injection-moulded fittings Characteristic Requirements Test parameters Test method Resistance to internal pressure, 140 h a b c
No failure during the test period End caps Test temperature
Orientation Number of test pieces Circumferential stress Conditioning period
Type of test Test period Type A or Type B
80 °C Free 3 4,2 MPa Shall conform to
EN ISO 1167-1 Water-in-water 140 h EN ISO 1167-1 and EN ISO 1167-2 Resistance to internal pressure 1000 h a b c
No failure during the test period End caps Test temperature
Orientation Number of test pieces Circumferential stress Conditioning period
Type of test Test period Type A or Type B
95 °C Free 3 2,5 MPa Shall conform to
EN ISO 1167-1 Water-in-water 1 000 h EN ISO 1167-1 and EN ISO 1167-2 Melt mass-flow rate ≤ 1,5 g/10 min Temperature Loading mass 230 °C
2,16 kg EN ISO 1133:2005 condition M Thermal stability, OITd
≥ 8 min Temperature 200 °C EN 728 a This requirement does not apply to the specified intermediate layer of a Type A1 pipe. b For the extrusion compounds for the internal and external layers of a multilayer pipe, this test shall be carried out in the form of a solid wall pipe made from the relevant material(s). c For injection-moulding compounds this test shall be carried out in the form of an injection-moulded, or extruded sample in solid wall pipe form made from the relevant material. d This requirement is only valid for pipes and fittings intended to be jointed in field by fusing or welding.
4.3.3 Melt mass-flow rate classification Materials for pipes and fittings intended for in field jointing by fusion or welding, shall be designated by the following MFR classes: — Class A: MFR ≤ 0,3 g/10 min; — Class B: 0,3 g/10 min < MFR ≤ 0,6 g/10 min; — Class C: 0,6 g/10 min < MFR ≤ 0,9 g/10 min; — Class D: 0,9 g/10 min < MFR ≤ 1,5 g/10 min.



EN 13476-2:2007 (E) 12 In the case where a raw material, because of its MFR tolerance arbitrarily falls in one of two adjacent classes, the manufacturer of the components may mark the MFR class on the product as follows: — MFR value across the border between A and B it is permitted to classify as class A; — MFR value across the border between B and C it is permitted to classify as class C; — MFR value across the border between C and D it is permitted to classify as class D. 4.3.4 Utilisation of non-virgin materials For the utilisation of non-virgin PP materials, conditions and requirements are given in Annex D. NOTE Annex J gives a survey of the possible use of reprocessable and recyclable materials. 4.4 Polyethylene (PE) 4.4.1 General The base material shall be
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.