Magnetic materials - Part 15: Methods for the determination of the relative magnetic permeability of feebly magnetic materials (IEC 60404-15:2012/A1:2016)

Magnetische Werkstoffe - Teil 15: Verfahren zur Bestimmung der Permeabilitätszahl schwachmagnetischer Werkstoffe (IEC 60404-15:2012/A1:2016)

Matériaux magnétiques - Partie 15: Méthodes de détermination de la perméabilité magnétique relative des matériaux faiblement magnétiques (IEC 60404-15:2012/A1:2016)

Magnetni materiali - 15. del: Metode za ugotavljanje relativne magnetne permeabilnosti mehkomagnetnih materialov (IEC 60404-15:2012/A1:2016) - Dopolnilo A1

General Information

Status
Published
Publication Date
08-Mar-2017
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
02-Mar-2017
Due Date
07-May-2017
Completion Date
09-Mar-2017

Relations

Buy Standard

Amendment
EN 60404-15:2013/A1:2017
English language
8 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 60404-15:2013/A1:2017
01-maj-2017
Magnetni materiali - 15. del: Metode za ugotavljanje relativne magnetne
permeabilnosti mehkomagnetnih materialov (IEC 60404-15:2012/A1:2016) -
Dopolnilo A1
Magnetic materials - Part 15: Methods for the determination of the relative magnetic
permeability of feebly magnetic materials (IEC 60404-15:2012/A1:2016)
Magnetische Werkstoffe - Teil 15: Verfahren zur Bestimmung der Permeabilitätszahl
schwachmagnetischer Werkstoffe (IEC 60404-15:2012/A1:2016)
Matériaux magnétiques - Partie 15: Méthodes de détermination de la perméabilité
magnétique relative des matériaux faiblement magnétiques (IEC 60404-
15:2012/A1:2016)
Ta slovenski standard je istoveten z: EN 60404-15:2012/A1:2017
ICS:
17.220.20 0HUMHQMHHOHNWULþQLKLQ Measurement of electrical
PDJQHWQLKYHOLþLQ and magnetic quantities
29.030 Magnetni materiali Magnetic materials
SIST EN 60404-15:2013/A1:2017 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 60404-15:2013/A1:2017

---------------------- Page: 2 ----------------------

SIST EN 60404-15:2013/A1:2017


EUROPEAN STANDARD EN 60404-15:2012/A1

NORME EUROPÉENNE

EUROPÄISCHE NORM
February 2017
ICS 29.030; 17.220.01

English Version
Magnetic materials - Part 15: Methods for the determination of
the relative magnetic permeability of feebly magnetic materials
(IEC 60404-15:2012/A1:2016)
Matériaux magnétiques - Partie 15: Méthodes de Magnetische Werkstoffe - Teil 15: Verfahren zur
détermination de la perméabilité magnétique relative des Bestimmung der Permeabilitätszahl schwachmagnetischer
matériaux faiblement magnétiques Werkstoffe
(IEC 60404-15:2012/A1:2016) (IEC 60404-15:2012/A1:2016)
This amendment A1 modifies the European Standard EN 60404-15:2012; it was approved by CENELEC on 2017-01-09. CENELEC
members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this amendment the
status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This amendment exists in three official versions (English, French, German). A version in any other language made by translation under the
responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as
the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden,
Switzerland, Turkey and the United Kingdom.



European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2017 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
 Ref. No. EN 60404-15:2012/A1:2017 E

---------------------- Page: 3 ----------------------

SIST EN 60404-15:2013/A1:2017
EN 60404-15:2012/A1:2017

European foreword
The text of document 68/531/CDV, future IEC 60404-15:2012/A1, prepared by IEC/TC 68 "Magnetic
alloys and steels" was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as
EN 60404-15:2012/A1:2017.

The following dates are fixed:
• latest date by which the document has to be (dop) 2017-10-09
implemented at national level by
publication of an identical national
standard or by endorsement
(dow) 2020-01-09
• latest date by which the national
standards conflicting with the
document have to be withdrawn

Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such
patent rights.

Endorsement notice
The text of the International Standard IEC 60404-15:2012/A1:2016 was approved by CENELEC as a
European Standard without any modification.
2

---------------------- Page: 4 ----------------------

SIST EN 60404-15:2013/A1:2017



IEC 60404-15

®


Edition 1.0 2016-12




INTERNATIONAL



STANDARD




NORME



INTERNATIONALE




A MENDMENT 1

AM ENDEMENT 1





Magnetic materials –

Part 15: Methods for the determination of the relative magnetic permeability of

feebly magnetic materials




Matériaux magnétiques –

Partie 15: Méthodes de détermination de la perméabilité magnétique relative des


matériaux faiblement magnétiques













INTERNATIONAL

ELECTROTECHNICAL

COMMISSION


COMMISSION

ELECTROTECHNIQUE


INTERNATIONALE




ICS 17.220.01; 29.030 ISBN 978-2-8322-3781-6



Warning! Make sure that you obtained this publication from an authorized distributor.

Attention! Veuillez vous assurer que vous avez obtenu cette publication via un distributeur agréé.

® Registered trademark of the International Electrotechnical Commission
Marque déposée de la Commission Electrotechnique Internationale

---------------------- Page: 5 ----------------------

SIST EN 60404-15:2013/A1:2017
– 2 – IEC 60404-15:2012/AMD1:2016
© IEC 2016
FOREWORD
This amendment has been prepared by IEC technical committee 68: Magnetic alloys and
steels.
The text of this amendment is based on the following documents:
CDV Report on voting
68/531/CDV 68/544/RVC

Full information on the voting for the approval of this amendment can be found in the report
on voting indicated in the above table.
The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC website under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.

___________

4.2 Principle
Replace the first sentence of the first paragraph with the following:
The relative magnetic permeability of a feebly magnetic test specimen is determined from the
magnetic polarization J and the corresponding magnetic field strength H measured using the
circuit shown in Figure 1 or Figure 5, using
Figure 1 – Circuit diagram for the solenoid method
Replace the existing title of Figure 1 with the following:
Figure 1 – Circuit diagram for the solenoid method with withdrawal of test specimen
Add a new Figure 5 with title and key, after Figure 1 and the note located below it, as follows:

---------------------- Page: 6 ----------------------

SIST EN 60404-15:2013/A1:2017
IEC 60404-15:2012/AMD1:2016 – 3 –
© IEC 2016
Air flux compensating coil
N
1
N
2
Test specimen
Flux coil
R
c
F
S
E
R
A
IEC

Key
A Current measuring device or ammeter
E d.c. power supply
F Flux integrator
N Solenoid

1
N Compensated search coil

2
R Variable resistor (controlling magnetizing current)
R Variable resistor (to adjust the output of the air flux compensating coil)

c
S Switch for reversing the current in the solenoid
Figure 5 – Circuit diagram for the solenoid method
with reversing of magnetizing current
Replace the existing Subclause 4.3.2 with the following:
4.3.2 Search coil for the solenoid method with withdrawal of test specimen. For the solenoid
method with withdrawal of test specimen, the search coil shall be wound on a nonmagnetic,
non-conducting former. Typically, for test specimens up to 30 mm in diameter, the internal
diameter of the aperture in the search coil is 32 mm to allow
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.