(Main)Radio-frequency connectors -- Part 29: Sectional specification - Miniature radio frequency coaxial connectors model screw, snap-on, push-pull or quick-lock, slide-in (rack and panel applications) - Characteristic impedance 50 ohms (type 1,0/2,3) - 50 omhs and 75 ohms applications
Radio-frequency connectors -- Part 29: Sectional specification - Miniature radio frequency coaxial connectors model screw, snap-on, push-pull or quick-lock, slide-in (rack and panel applications) - Characteristic impedance 50 ohms (type 1,0/2,3) - 50 omhs and 75 ohms applications
This part of IEC 61169, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for RF coaxial connectors with screw, snapon, push-pull or quick-lock, slide-in coupling (rack and panel applications) with a characterisctic impedance of 50 ohms (type 1,0/2,3) for 50 ohms and 75 ohms applications. The connectors are normally used with flexible and semi-rigid r.f. cables for low power applications in conjunction with 50 & cables in an operating frequency range up to 10 GHz or in conjunction with 75 & cables up to 2 GHz. It describes the interface dimensions for general purpose grade 2 connectors, dimensional details for standard test connectors, grade 0, together with gauging information and the mandatory tests selected from IEC 61169-1, applicable to all DS relating to type 1,0/2,3 connectors. This specification indicates the recommended performance characteristics to be considered when writing a DS and covers test schedules and inspection requirements.
Hochfrequenz-Steckverbinder -- Teil 29: Rahmenspezifikation - Koaxiale Miniatur-Hochfrequenzsteckverbinder mit Schraub-, Einrast-, Push-pull- oder Schnellverschluss-, Einschubkupplung (Einschubausführung) - Wellenwiderstand 50-Ohm (Typ 1,0/2,3) - 50-Ohm- und 75-Ohm-Anwendungen
Connecteurs pour fréquences radioélectriques -- Partie 29: Spécification intermédiaire - Connecteurs coaxiaux miniatures pour fréquences radioélectriques avec accouplements de type vis, pousser-tirer et encliquetage, ou glis (applications de panneau et fond de panier ) - Impédance caractéristique 50 ohms (type 1,0/2,3) - Applications à 50 ohms et 75 ohms
Radiofrekvenčni konektorji - 29. del: Področna specifikacija - Miniaturni radiofrekvenčni koaksialni konektorji: navojni, natični, zaklepni, zdrsni (za stojalo in ploščo) - Karakteristična impedanca 50 ohmov (tip 1.0/2,3) - Uporaba za 50 ohmov in 75 ohmov (IEC 61169-29:2005)
General Information
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 61169-29:2008
01-januar-2008
5DGLRIUHNYHQþQLNRQHNWRUMLGHO3RGURþQDVSHFLILNDFLMD0LQLDWXUQL
UDGLRIUHNYHQþQLNRDNVLDOQLNRQHNWRUMLQDYRMQLQDWLþQL]DNOHSQL]GUVQL]DVWRMDOR
LQSORãþR.DUDNWHULVWLþQDLPSHGDQFDRKPRYWLS8SRUDED]D
RKPRYLQRKPRY,(&
Radio-frequency connectors - Part 29: Sectional specification - Miniature radio frequency
coaxial connectors model screw, snap-on, push-pull or quick-lock, slide-in (rack and
panel applications) - Characteristic impedance 50 ohms (type 1,0/2,3) - 50 omhs and 75
ohms applications (IEC 61169-29:2005)
Hochfrequenz-Steckverbinder - Teil 29: Rahmenspezifikation - Koaxiale Miniatur-
Hochfrequenzsteckverbinder mit Schraub-, Einrast-, Push-pull- oder Schnellverschluss-,
Einschubkupplung (Einschubausführung) - Wellenwiderstand 50-Ohm (Typ 1,0/2,3) - 50-
Ohm- und 75-Ohm-Anwendungen (IEC 61169-29:2005)
Connecteurs pour fréquences radioélectriques - Partie 29: Spécification intermédiaire -
Connecteurs coaxiaux miniatures pour fréquences radioélectriques avec accouplements
de type vis, pousser-tirer et encliquetage, ou glis (applications de "panneau" et "fond de
panier") - Impédance caractéristique 50 ohms (type 1,0/2,3) - Applications a 50 ohms et
75 ohms (IEC 61169-29:2005)
Ta slovenski standard je istoveten z: EN 61169-29:2005
ICS:
33.120.30 5DGLRIUHNYHQþQLNRQHNWRUML R.F. connectors
5)
SIST EN 61169-29:2008 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
EUROPEAN STANDARD EN 61169-29
NORME EUROPÉENNE
EUROPÄISCHE NORM September 2005
ICS 33.120.30
English version
Radio-frequency connectors
Part 29: Sectional specification –
Miniature radio frequency coaxial connectors model screw, snap-on,
push-pull or quick-lock, slide-in (rack and panel applications) –
Characteristic impedance 50 ohms (type 1,0/2,3) –
50 ohms and 75 ohms applications
(IEC 61169-29:2005)
Connecteurs pour fréquences radioélectriques Hochfrequenz-Steckverbinder
Partie 29: Spécification intermédiaire – Teil 29: Rahmenspezifikation –
Connecteurs coaxiaux miniatures pour Koaxiale Miniatur-Hochfrequenzsteckverbinder
fréquences radioélectriques avec mit Schraub-, Einrast-, Push-pull- oder
accouplements de type vis, pousser-tirer Schnellverschluss-, Einschubkupplung
et encliquetage, ou glis (applications de (Einschubausführung) –
"panneau" et "fond de panier") – Wellenwiderstand 50-Ohm (Typ 1,0/2,3) –
Impédance caractéristique 50 ohms 50-Ohm- und 75-Ohm-Anwendungen
(type 1,0/2,3) – (IEC 61169-29:2005)
Applications à 50 ohms et 75 ohms
(CEI 61169-29:2005)
This European Standard was approved by CENELEC on 2005-07-01. CENELEC members are bound to
comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and
notified to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, Czech
Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden,
Switzerland and United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels
© 2005 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61169-29:2005 E
---------------------- Page: 2 ----------------------
EN 61169-29:2005 - 2 -
Foreword
The text of document 46F/27/FDIS, future edition 1 of IEC 61169-29, prepared by SC 46F, R.F. and
microwave passive components, of IEC TC 46, Cables, wires, waveguides, R.F. connectors, R.F. and
microwave passive components and accessories, was submitted to IEC-CENELEC parallel vote and
was approved by CENELEC as EN 61169-29 on 2005-07-01.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2006-04-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2008-07-01
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of the International Standard IEC 61169-29:2005 was approved by CENELEC as a European
Standard without any modification.
__________
---------------------- Page: 3 ----------------------
- 3 - EN 61169-29:2005
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
NOTE Where an international publication has been modified by common modifications, indicated by (mod), the relevant
EN/HD applies.
Publication Year Title EN/HD Year
IEC 61169-1 1992 Radio-frequency connectors EN 61169-1 1994
Part 1: Generic specification - General
requirements and measuring methods
---------------------- Page: 4 ----------------------
NORME CEI
INTERNATIONALE
IEC
61169-29
INTERNATIONAL
Première édition
STANDARD
First edition
2005-06
Connecteurs pour fréquences radioélectriques –
Partie 29:
Spécification intermédiaire –
Connecteurs coaxiaux miniatures pour fréquences
radioélectriques avec accouplements de type vis,
pousser-tirer et encliquetage, ou glis (applications
de «panneau» et «fond de panier») –
Impédance caractéristique 50 Ω (type 1,0/2,3) –
Applications à 50 Ω et 75 Ω
Radio-frequency connectors –
Part 29:
Sectional specification –
Miniature radio frequency coaxial connectors
model screw, snap-on, push-pull or quick-lock,
slide-in (rack and panel applications ) –
Characteristic impedance 50 Ω (type 1,0/2,3) –
50 Ω and 75 Ω applications
IEC 2005 Droits de reproduction réservés Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in any
utilisée sous quelque forme que ce soit et par aucun procédé, form or by any means, electronic or mechanical, including
électronique ou mécanique, y compris la photocopie et les photocopying and microfilm, without permission in writing from
microfilms, sans l'accord écrit de l'éditeur. the publisher.
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
CODE PRIX
U
PRICE CODE
Commission Electrotechnique Internationale
International Electrotechnical Commission
МеждународнаяЭлектротехническаяКомиссия
Pour prix, voir catalogue en vigueur
For price, see current catalogue
---------------------- Page: 5 ----------------------
61169-29 IEC:2005 – 3 –
CONTENTS
FOREWORD.5
1 Scope.9
2 Normative references .9
3 IEC type designation .11
4 Interface information.13
4.1 Dimensions .13
4.2 Gauges .21
5 Quality assessment procedures.29
5.1 General .29
5.2 Ratings and characteristics .29
5.3 Test schedule and inspection requirements .37
5.4 Procedures.43
6 Instructions for preparation of detail specifications .43
6.1 General .43
6.2 Identification of the detail specification .43
6.3 Identification of the component.43
6.4 Performance.45
6.5 Marking, ordering information and related matters .45
6.6 Selection of tests, test conditions and severities.45
6.7 Blank detail specification pro-forma for type 1,0/2,3 connector .47
Figure 1 – Interfaces (for dimensions, see Table 1) .13
Figure 2 – Locking devices (for dimensions, see Table 2) .17
Figure 3 – Gauge pin for centre contact of socket connector.21
Figure 4 – Outer contact sizing and retention force gauges A and B .23
Figure 5 – Plug .25
Figure 6 – Socket .27
Table 1 – Dimensions of the interfaces .15
Table 2 – Dimensions of the locking devices.19
---------------------- Page: 6 ----------------------
61169-29 IEC:2005 – 5 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
RADIO-FREQUENCY CONNECTORS –
Part 29: Sectional specification –
Miniature radio frequency coaxial connectors model screw, snap-on,
push-pull or quick-lock, slide-in (rack and panel applications) –
Characterisctic impedance 50 Ω (type 1,0/2,3) –
50 Ω and 75 Ω applications
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61169-29 has been prepared by subcommittee 46F: R.F. and
microwave passive components of IEC technical committee 46: Cables, wires, waveguides,
R.F. connectors, R.F. and microwave passive components and accessories.
This standard cancels and replaces IEC 60169-29, published in 1995.
---------------------- Page: 7 ----------------------
61169-29 IEC:2005 – 7 –
The text of this standard is based on the following documents:
FDIS Report on voting
46F/27/FDIS 46F/30/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
IEC 61169 consists of the following parts, under the general title Radio-frequency connectors:
Part 1: Generic specification – General requirements and measuring methods
Part 1-1: Single multi-series dual language blank detail specification (BDS)
Part 2: Sectional specification – Radio frequency coaxial connectors of type 9,52
Part 24: Sectional specification – Radio frequency coaxial connectors with screw coupling,
typically for use in 75 ohm cable distribution systems (type F)
Part 29: Sectional specification – Miniature radio frequency coaxial connectors model
screw, snap-on, push-pull or quick-lock, slide-in (rack and panel applications) –
Characteristic impedance 50 ohms (type 1,0/2,3) 50 and 75 ohms applications
Part 31: RF coaxial with inner diameter of outer conductor 1,0 mm (0,039 in) with screw
coupling – Characteristic impedance 50 ohms (type 1,0)
Part 32: RF coaxial connectors with inner diameter of outer conductor 1,85 mm (0,072 in)
with screw coupling – Characteristic impedance 50 ohms (type 1,85)
Part 33: Sectional Specification (SS) for Type BMA R.F. connectors
Part 36: Microminiature r.f. connectors with snap-on coupling – Characteristic impedance
50 Ohms (Type MCX)
The committee has decided that the contents of this publication will remain unchanged until
the maintenance result date indicated on the IEC web site under "http://webstore.iec.ch" in
the data related to the specific publication. At this date, the publication will be
• reconfirmed;
• withdrawn;
• replaced by a revised edition, or
• amended.
---------------------- Page: 8 ----------------------
61169-29 IEC:2005 – 9 –
RADIO-FREQUENCY CONNECTORS –
Part 29: Sectional specification –
Miniature radio frequency coaxial connectors model screw, snap-on,
push-pull or quick-lock, slide-in (rack and panel applications) –
Characterisctic impedance 50 Ω (type 1,0/2,3) –
50 Ω and 75 Ω applications
1 Scope
This part of IEC 61169, which is a sectional specification (SS), provides information and rules
for the preparation of detail specifications (DS) for RF coaxial connectors with screw, snap-
on, push-pull or quick-lock, slide-in coupling (rack and panel applications) with a
characterisctic impedance of 50 Ω (type 1,0/2,3) for 50 Ω and 75 Ω applications.
The connectors are normally used with flexible and semi-rigid r.f. cables for low power
applications in conjunction with 50 Ω cables in an operating frequency range up to 10 GHz or
in conjunction with 75 Ω cables up to 2 GHz.
It describes the interface dimensions for general purpose grade 2 connectors, dimensional
details for standard test connectors, grade 0, together with gauging information and the
mandatory tests selected from IEC 61169-1, applicable to all DS relating to type 1,0/2,3
connectors.
This specification indicates the recommended performance characteristics to be considered
when writing a DS and covers test schedules and inspection requirements.
2 Normative references
The following referenced documents are indispensable for the application of this document.
For dated references, only the edition cited applies. For undated references, the latest edition
of the referenced document (including any amendments) applies.
IEC 61169-1:1992, Radio-frequency connectors – Part 1: Generic specification – General
requirements and measuring methods
---------------------- Page: 9 ----------------------
61169-29 IEC:2005 – 11 –
3 IEC type designation
Type designations are given for each of the various coupling mechanisms:
– Screw – the coupling mechanism consists of a coupling nut (on the plug ) and a thread (on
the socket). The tightening torque is achieved by hand. The engagement and separation
force depends on the mechanical dimensions of the inner and outer contacts of the plug
and socket.
– Snap on – the coupling mechanism consists of a spring device (on the plug) that fits in a
suitable shape of the body (on the socket). The engagement and separation force
depends on the mechanical dimensions of the inner and outer contact, of the spring device
and of the socket body. The coupling mechanism does not prevent accidental
disengagements.
– Push pull or Quick lock (hereafter called push pull) – the coupling mechanism consists of
a spring device (on the plug) that fits in a suitable shape of the body (on the socket). The
engagement and separation force depends on the mechanical dimensions of the inner and
outer contact, of the spring element and of the socket body. This coupling mechanism
prevents accidental disengagements.
– Slide in – the coupling mechanism consists of a nut (on the plug) which allows a float
mounting on the panel preventing a radial misalignment. The engagement and separation
force depends on the mechanical dimensions of the inner and outer contacts of the plug
and socket. In case of rack and panel applications, the separation range of panels may
differ from the fully mated position by 1,7 mm.
Connectors conforming to this part of IEC 61169 shall be designated by:
a) the reference to this part of IEC 61169: IEC 61169-29;
b) the grade number:
Grade 0 = standard test connector = G0
Grade 2 = general purpose connector = G2
c) identification number (see Clause 8 of IEC 61169-1).
---------------------- Page: 10 ----------------------
61169-29 IEC:2005 – 13 –
4 Interface information
4.1 Dimensions
4.1.1 General purpose connectors - Grade 2
Millimetre dimensions are original dimensions. All undimensioned pictorial configurations are
for reference purposes only.
Flared to meet
the gauging S
Plug
requirement
F
B
A E
Pin contact
D
C
Reference plane
electrical and mechanical
0,8 ± 0,1
Radius
(0,030 ± 0,002)
30° ± 2°
K
G H R
Socket
0,3 max.
L
Radius
(0,010 max.)
I
M
N
T
Slotted and closed to meet
the gauging requirement
Socket resilient
contact
P
O
IEC 820/05
Figure 1 – Interfaces (for dimensions, see Table 1)
---------------------- Page: 11 ----------------------
61169-29 IEC:2005 – 15 –
Table 1 – Dimensions of the interfaces
mm in
Ref. Note
Min. Max. Min. Max.
A 0,475 0,520 0,018 7 0,020 5 Diameter
B 4,5 0,177
C 5,5 0,217
D 1,15 0,045
E (*) 1 nominal 0,039 nominal Diameter
F 5,4 5,7 0,213 0,224
G 3,00 3,06 0,118 0,120 Diameter
H 4,03 4,14 0,159 0,163 Diameter
I 1,8 1,9 0,071 0,075
K
M 5,5 × 0,5
L 0,5 0,6 0,020 0,024
M 5,8 5,9 0,228 0,232
N 6,4 6,5 0,252 0,256
O (*) 1 nominal 0,039 nominal Diameter
P 1,15 1,75 0,045 0,069
R 3,525 3,600 0,138 8 0,141 7 Diameter
S 2,3 nominal 0,091 nominal Diameter
T 4,5 0,177
(*) = only for 50 Ω version.
---------------------- Page: 12 ----------------------
61169-29 IEC:2005 – 17 –
Figure 2a – Screw
A
D
B
Biased in the forward
Reference plane
direction
E
Reference plane
C
G F
Figure 2b – Snap-on
F
45 ± 2°
T
Biased in the forward
S
Figure 2b(bis) – Push-pull
direction
U
M
45 ± 2°
O P
H
I K
L*
R
* Separation of panels when fully mated
Figure 2c – Slide-in (rack and panel applications)
IEC 821/05
Figure 2 – Locking devices (for dimensions, see Table 2)
---------------------- Page: 13 ----------------------
61169-29 IEC:2005 – 19 –
Table 2 – Dimensions of the locking devices
mm in
Ref. Note
Min. Max. Min. Max.
A 6,44 6,50 0,254 0,256 Diameter
B 8,55 8,9 0,337 0,350
C 13,3 13,5 0,524 0,531
D 2,7 3,9 0,106 0,154
E
M 5,5 × 0,5 Thread
F 1,95 2,05 0,077 0,081
G
6,4 0,252
H 8,25 8,40 0,325 0,331
I 7,5 7,6 0,295 0,299
K 3,10 3,15 0,122 0,124
L 11,9 13,6 0,469 0,535
M 4,8 4,9 0,189 0,193
O 7,3 0,287 Diameter
P 4,2 4,26 0,165 0,168 Diameter
R 1,4 1,6 0,055 0,063
S 6,1 0,240
T
7,9 0,311 Diameter
U 7,6 0,299
---------------------- Page: 14 ----------------------
61169-29 IEC:2005 – 21 –
4.2 Gauges
4.2.1 Gauges for general purpose connectors
Millimetre dimensions are original dimensions. All undimensioned pictorial configurations are
for reference purposes only.
4.2.1.1 Gauge for socket centre contact
25° ± 5°
∅a
2,0 min.
(0,079 min.)
IEC 822/05
NOTE Dimensions are in millimetres. Figures in brackets represent inches.
Gauge A Gauge B
Maximum material for Minimum material for
sizing purposes measurement of gauge
retention force
Mass (weight) of gauge (20 ± 1) g
mm in mm in
Ref.
Min. Max. Min. Max. Min. Max. Min. Max.
∅a 0,516 0,520 0,020 3 0,020 5 0,471 0,475 0,081 5 0,018 7
Material: steel, polished
Surface roughness Ra: 0,4 µm (16 µin) max.
Figure 3 – Gauge pin for centre contact of socket connector
Test procedure:
Gauge A shall be inserted once only into the socket centre contact. This is a sizing operation.
After this, gauge B shall be inserted into the socket centre contact. The contact shall support
the mass of the gauge in a vertical downward attitude.
NOTE Gauge A is used for qualification approval tests only (see 9.3.4 of IEC 61169-1). The maximum diameter of
gauge A corresponds to the maximum diameter of a pin contact.
---------------------- Page: 15 ----------------------
61169-29 IEC:2005 – 23 –
4.2.1.2 Gauge for outer contact of plug connector
0,2 ± 0,05
Radius
(0,008 ± 0,002)
0,3 ± 0,05
Radius
(0,012 ± 0,002)
30° ± 2°
A
∅a
D
B*
C
IEC 823/05
NOTE Dimensions are in millimetres. Figures in brackets represent inches.
* Surface roughness to apply on this length of inside surface (∅ 1).
mm in
Ref. Note
Min. Max. Min. Max.
A 4,1 0,161 Diameter
B
7 nominal 0,276
C 9 0,354
D 0,5 0,6 0,020 0,024
Gauge A Gauge B
Maxumum material for Minimum material for
sizing purposes measurement of gauge
retention force
Mass (weight) of gauge (70 ± 1) g
mm in mm in
Ref.
Min. Max. Min. Max. Min. Max. Min. Max.
∅a 3,000 3,006 0,118 1 0,118 3 3,060 3,068 0,120 5 0,120 8
Material: steel, polished
Surface roughness Ra: 0,4 µm (16 µin) max.
Figure 4 – Outer contact sizing and retention force gauges A and B
Test procedure:
The resilient plug outer conductor shall be inserted once only into gauge A. This is a sizing
operation.
After this, the resilient plug outer conductor shall be inserted into gauge B. The conductor
shall support the mass of the gauge in a vertical downward attitude.
---------------------- Page: 16 ----------------------
61169-29 IEC:2005 – 25 –
4.2.2 Dimensions – Standard test connectors – Grade 0
Millimetre dimensions are original dimensions. All undimensioned pictorial configurations are
for reference purposes only.
A B
C
E
F
D
Pin contact
I
45° ± 2°
H
G
Reference plane
mechanical and electrical
IEC 824/05
mm in
Ref. Note
Min. Max. Min. Max.
A 2,99 3,00 0,117 7 0,118 1 Diameter
B 2,30 2,31 0,090 6 0,090 9 Diameter
C 5,40 5,70 0,213 0,224
D 0,50 0,52 0,020 1 0,020 5 Diameter
E 0,30 0,40 0,012 0,016
F 4,50 0,177
G
5,30 5,50 0,209 0,217
H 0,95 1,15 0,037 0,045
I 0,99 1,00 0,039 0,039 4 Diameter
Figure 5 – Plug
---------------------- Page: 17 ----------------------
61169-29 IEC:2005 – 27 –
0,8 ± 0,05
Radius
(0,031 ± 0,002)
30° ± 2°
B
A C D
E
0,3 max.
Radius
(0,010 max.)
F
G
H
I
L
M
Socket resilient
P R
S T
contact
N
K
O
The locking devices shall be as indicated in Figure 2.
IEC 825/05
NOTE Dimensions are in millimetres. Figures in brackets represent inches.
mm in
Ref. Note
Min. Max. Min. Max.
A Thread
M 5,5 × 0,5
B 2,30 2,31 0,090 6 0,090 9 Diameter
C 3,00 3,01 0,118 1 0,118 5 Diameter
D
4,03 4,14 0,159 0,163 Diameter
E 0,50 0,60 0,020 0,024
F 1,80 1,90 0,071 0,075
G 5,80 5,90 0,228 0,232
H 6,40 6,50 0,252 0,256
I 4,35 4,45 0,171 0,175
K 0,99 1,01 0,039 0,039 8 Diameter
L 1,30 1,50 0,051 0,059
M 0,10 0,30 0,004 0,012
N 2,30 2,50 0,091 0,098
O 4,5 nominal 0,177 nominal
P 0,25 0,27 0,009 8 0,010 6 Note 1
R 0,59 0,60 0,023 2 0,023 6 Note 2; Diameter
S 0,94 nominal 0,037 nominal Diameter
T 1,10 1,11 0,043 3 0,043 7 Diameter
NOTE 1 Slotted and closed to meet the gauging requirement.
NOTE 2 Before slotting and closing.
Figure 6 – Socket
---------------------- Page: 18 ----------------------
61169-29 IEC:2005 – 29 –
5 Quality assessment procedures
5.1 General
The following subclauses provide recommended ratings, performance and test conditions to
be considered when writing a detail specification (DS). They also provide an appropriate
schedule of tests with minimum levels of conformance inspection.
5.2 Ratings and characteristics
The RF connectors defined in this part of IEC 61169 are designed for use with a variety of
flexible and semi-rigid coaxial cables and in microwave integrated circuits and similar
uncabled applications.
---------------------- Page: 19 ----------------------
61169-29 IEC:2005 – 31 –
Test
50 Ω 75 Ω
method of
Ratings
IEC
and characteristics
61169-1
Value Remarks Value Remarks
Subclause
Electrical General General
purpose purpose
connectors connectors
Frequency range Up to 10 GHz Up to 2 GHz
Characteristic impedance 50 Ω Nominal 50 Ω Nominal
a
Reflection factor 9.2.1
– flexible cables ≤ 0,05 Up to 1 GHz ≤ 0,10 Up to 2 Ghz
Up to 4 GHz
≤ 0,07
Up to 8 GHz
≤ 0,15
– semi-rigid cables ≤ 0,03 Up to 1 GHz ≤ 0,10 Up to 2 GHz
Up to 4 GHz
≤ 0,06
Up to 10 GHz
≤ 0,10
Centre contact resistance 9.2.3
– initial
≤ 4 mΩ ≤ 4 mΩ
Full-crimp
≤ 20 mΩ
right-angle
– after conditioning Initial + 6 mΩ Initial + 6 mΩ
Outer conductor continuity 9.2.3
– initial
≤ 2,5 mΩ ≤ 2,5 mΩ
– after conditioning Initial + 5 mΩ Initial + 5 mΩ
Insulation resistance 9.2.5
– initial ≥ 1 GΩ ≥ 1 GΩ
– after conditioning
≥ 200 MΩ ≥ 200 MΩ
b c
Proof voltage at sea level 9.2.6 750 V 750 V
4,4 kPa 4,4 kPa
approximately approximately
b c
Proof voltage at 4,4 kPa 9.4.2 150 V 150 V
equivalent to equivalent to
20 km altitude 20 km altitude
Climatic sequence voltage 9.4.3 250 V 250 V
b c
at sea level
Climatic sequence voltage 9.4.2 65 V 4,4 kPa 65 V 4,4 kPa
b c
4,4 kPa approximately approximately
equivalent to equivalent to
20 km altitude 20 km altitude
Screening effectiveness 9.2.8
– screw coupling
a ≥ 90 dB Z ≤ 3,16 mΩ a ≥ 90 dB Z ≤ 3,16 mΩ
s t s t
at 1 GHz at 1 GHz
– slide-in, snap-on and push
a ≥ 70 dB Z ≤ 31,5 mΩ a ≥ 70 dB Z ≤ 31,5 mΩ
s
...