SIST EN 300 396-8-4 V1.1.1:2003
(Main)Terrestrial Trunked Radio (TETRA); Technical requirements for Direct Mode Operation (DMO); Part 8: Protocol Implementation Conformance Statement (PICS) proforma specification; Sub-part 4: Type 2 repeater Air Interface (AI)
General Information
- Abstract
To produce a PICS proforma for Direct Mode Operation of Repeater type 2
- Status
- Published
- Publication Date
- 30-Nov-2003
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 01-Dec-2003
- Due Date
- 01-Dec-2003
- Completion Date
- 01-Dec-2003
Overview
SIST EN 300 396-8-4 V1.1.1:2003 specifies the Protocol Implementation Conformance Statement (PICS) proforma for Terrestrial Trunked Radio (TETRA) Direct Mode Operation (DMO), specifically for Type 2 repeater Air Interface (AI). Developed by the Slovenski inštitut za standardizacijo (SIST) and aligned with EN 300 396-8-4, this European Standard enables suppliers and test organizations to assess and document conformance of implementing direct mode operations within TETRA networks.
The standard is essential for network equipment suppliers, integrators, and testing bodies who manage or verify DMO functionalities in TETRA environments, particularly for the Type 2 repeater scenario-a critical element for extending coverage and ensuring robust, reliable radio communications in field operations.
Key Topics
Protocol Implementation Conformance Statement (PICS):
The standard details the PICS proforma as a structured checklist to document and verify which DMO features and options are supported by an implementation, providing clarity and transparency.Type 2 Repeater Air Interface (AI):
Focuses on the conformance requirements specifically for Type 2 repeaters, as detailed in TETRA DMO technical specifications.Layered Protocol Structure:
Addresses conformance for both Layer 3 (Direct Mode Call Control - DMCC) and Layer 2 (Data Link Layer - DLL) of the communications protocol stack for mobile stations and repeaters operating in DMO.Filling and Usage Guidelines:
Includes instructions on how to fill out the PICS proforma, ensuring proper identification of products, suppliers, clients, and scope of conformance. The proforma enables consistent reporting and simplifies the comparison of different implementations.Mandatory and Optional Features:
Differentiates between mandatory, optional, and conditional items, facilitating compliance checks against TETRA DMO standards.
Applications
The standard's practical value lies in supporting the following activities:
Product Certification:
Ensures that TETRA network elements, especially DMO Type 2 repeaters and compatible mobile stations, fulfill the minimum conformance requirements prior to deployment or certification.Interoperability Testing:
The PICS proforma provides a unified reference for test laboratories when performing interoperability or integration testing, reducing ambiguity in feature support claims.Specification Compliance:
Manufacturers and developers use the proforma to declare which features are implemented and supported, streamlining procurement and integration processes for end users.Quality Assurance:
By documenting supported features and identifying any limitations, the standard helps organizations audit and verify radio system quality, especially where mission-critical communication is involved.
Related Standards
For comprehensive application and to ensure full interoperability within TETRA radio networks, the following standards are closely related:
EN 300 396-7:
Technical requirements for Direct Mode Operation (DMO) - Type 2 repeater air interface.EN 300 396-3:
Technical requirements for DMO - Mobile Station to Mobile Station (MS-MS) air interface protocol.EN 300 396-8-2:
PICS proforma specification for DMO Type 1 repeater Air Interface.ISO/IEC 9646-7:
Conformance testing methodology and framework - Implementation Conformance Statements.ETS 300 406:
Methods for protocol and profile conformance testing.
By adhering to SIST EN 300 396-8-4 V1.1.1:2003, organizations support robust, interoperable, and standardized TETRA direct mode operations, reinforcing dependable professional mobile radio communications in sectors such as public safety, utilities, and transport.
Get Certified
Connect with accredited certification bodies for this standard

ANCE
Mexican certification and testing association.

Intertek Slovenia
Intertek testing, inspection, and certification services in Slovenia.
LNE (Laboratoire National de Métrologie et d'Essais)
French national laboratory for metrology and testing.
Sponsored listings
Frequently Asked Questions
SIST EN 300 396-8-4 V1.1.1:2003 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Terrestrial Trunked Radio (TETRA); Technical requirements for Direct Mode Operation (DMO); Part 8: Protocol Implementation Conformance Statement (PICS) proforma specification; Sub-part 4: Type 2 repeater Air Interface (AI)". This standard covers: To produce a PICS proforma for Direct Mode Operation of Repeater type 2
To produce a PICS proforma for Direct Mode Operation of Repeater type 2
SIST EN 300 396-8-4 V1.1.1:2003 is classified under the following ICS (International Classification for Standards) categories: 33.070.10 - Terrestrial Trunked Radio (TETRA). The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 300 396-8-4 V1.1.1:2003 is associated with the following European legislation: Standardization Mandates: BC-T-344, T-172. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
SIST EN 300 396-8-4 V1.1.1:2003 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.REUDWRYDQMHRIRUPDTerrestrial Trunked Radio (TETRA); Technical requirements for Direct Mode Operation (DMO); Part 8: Protocol Implementation Conformance Statement (PICS) proforma specification; Sub-part 4: Type 2 repeater Air Interface (AI)33.070.10Prizemni snopovni radio (TETRA)Terrestrial Trunked Radio (TETRA)ICS:Ta slovenski standard je istoveten z:EN 300 396-8-4 Version 1.1.1SIST EN 300 396-8-4 V1.1.1:2003en01-december-2003SIST EN 300 396-8-4 V1.1.1:2003SLOVENSKI
STANDARD
ETSIEN300396-8-4V1.1.1(2001-01)EuropeanStandard(Telecommunicationsseries)TerrestrialTrunkedRadio(TETRA);TechnicalrequirementsforDirectModeOperation(DMO);Part8:ProtocolImplementationConformanceStatement(PICS)proformaspecification;Sub-part4:Type2repeaterAirInterface(AI)SIST EN 300 396-8-4 V1.1.1:2003
ETSIETSIEN300396-8-4V1.1.1(2001-01)2ReferenceDEN/TETRA-02007-8-4KeywordsDMO,ICS,PICS,radio,TETRAETSI650RoutedesLuciolesF-06921SophiaAntipolisCedex-FRANCETel.:+33492944200Fax:+33493654716SiretN°34862356200017-NAF742CAssociationàbutnonlucratifenregistréeàlaSous-PréfecturedeGrasse(06)N°7803/88ImportantnoticeIndividualcopiesofthepresentdocumentcanbedownloadedfrom:http://www.etsi.orgThepresentdocumentmaybemadeavailableinmorethanoneelectronicversionorinprint.Inanycaseofexistingorperceiveddifferenceincontentsbetweensuchversions,thereferenceversionisthePortableDocumentFormat(PDF).Incaseofdispute,thereferenceshallbetheprintingonETSIprintersofthePDFversionkeptonaspecificnetworkdrivewithinETSISecretariat.Usersofthepresentdocumentshouldbeawarethatthedocumentmaybesubjecttorevisionorchangeofstatus.InformationonthecurrentstatusofthisandotherETSIdocumentsisavailableathttp://www.etsi.org/tb/status/Ifyoufinderrorsinthepresentdocument,sendyourcommentto:editor@etsi.frCopyrightNotificationNopartmaybereproducedexceptasauthorizedbywrittenpermission.Thecopyrightandtheforegoingrestrictionextendtoreproductioninallmedia.©EuropeanTelecommunicationsStandardsInstitute2001.Allrightsreserved.SIST EN 300 396-8-4 V1.1.1:2003
ETSIETSIEN300396-8-4V1.1.1(2001-01)3ContentsIntellectualPropertyRights.5Foreword.5Introduction.61Scope.72References.73Definitionsandabbreviations.73.1Definitions.73.2Abbreviations.84ConformancetothisPICSproformaspecification.8AnnexA(normative):ProtocolICSproforma(PICS)forEN300396-4.9A.1GuidanceforcompletingthePICSproforma.9A.1.1Purposesandstructure.9A.1.2Abbreviationsandconventions.9A.1.3InstructionsforcompletingthePICSproforma.11A.2Identificationoftheimplementation.11A.2.1Dateofthestatement.11A.2.2ImplementationUnderTest(IUT)identification.11A.2.3SystemUnderTest(SUT)identification.12A.2.4Productsupplier.12A.2.5Client(ifdifferentfromproductsupplier).12A.2.6PICScontactperson.13A.3IdentificationoftheProtocol.13A.4Globalstatementofconformance.13A.5Roles.14A.6ProtocolsforDM-MSsupportingoperationwithatype2DM-REP(MS-REP2).14A.6.1MS-REP2DirectModeCallControl(DMCC)atLayer3.14A.6.1.1DMCCmajorcapabilities.14A.6.1.2Circuitmodecall.15A.6.1.3Circuitmodecallset-up.15A.6.1.4Circuitmodeservicesoffered.16A.6.1.5Shortdataservices.16A.6.1.6Typeofshortdataservice.17A.6.1.7Datatransmission.18A.6.1.8SDSuserdefineddata.18A.6.1.9DMCCPDUs.19A.6.1.10DMCCconstants.21A.6.1.11DMCCtimers.22A.6.2MS-REP2Datalinklayer(DLL)atLayer2.23A.6.2.1MS-REP2MACfeatures.23A.6.2.2MS-REP2-MACprocedures.23A.6.2.3MS-REP2MACPDUs.27A.6.2.4MS-REP2MACgeneratedmessages.28A.6.2.5MS-REP2MACconstants.28A.6.2.6MS-REP2MACtimers.30A.7DM-REPtype2Protocol(DM-REP2).31A.7.1DM-REP2Datalinklayer(DLL)atLayer2.31A.7.1.1Majorservices.31A.7.1.2DM-REP2MACfeatures.31SIST EN 300 396-8-4 V1.1.1:2003
ETSIETSIEN300396-8-4V1.1.1(2001-01)4A.7.1.3DM-REP2MACprocedures.32A.7.1.4DM-REP2MACPDUs.34A.7.1.5DM-REP2MACgeneratedmessages.34A.7.1.6DM-REP2MACconstants.34A.7.1.7DM-REP2MACtimers.35A.8PDUparametersforMS-REP2andDM-REP2usedinDMCCatlayer3andDLLatlayer2.36A.8.1MS-REP2PDUparametersforDMCCatlayer3.36A.8.1.1DM-SETUP.36A.8.1.2DM-SETUPPRES.36A.8.1.3DM-CONNECT.37A.8.1.4DM-DISCONNECT.37A.8.1.5DM-CONNECTACK.37A.8.1.6DM-OCCUPIED.38A.8.1.7DM-RELEASE.38A.8.1.8DM-TXCEASED.38A.8.1.9DM-TXREQUEST.39A.8.1.10DM-TXACCEPT.39A.8.1.11DM-PREEMPT.39A.8.1.12DM-PREACCEPT.39A.8.1.13DM-REJECT.39A.8.1.14DM-INFO.40A.8.1.15DM-SDSUDATA.40A.8.1.16DM-SDSDATA.41A.8.1.17DM-SDSACK.41A.8.2MS-REP2andDM-REP2PDUparametersforDLLatlayer2.42A.8.2.1DMAC-SYNCinSCH/S.42A.8.2.2DPRES-SYNCPDU.43A.8.2.3DMAC-DATA.44A.8.2.4DMAC-FRAG.44A.8.2.5DMAC-END.44A.8.2.6DMAC-USIGNAL.44A.8.3DM-MACgeneratedmessageparameters.45A.8.3.1DM-RESERVED.45A.8.3.2DM-SDSOCCUPIED.45A.8.3.3DM-TIMINGREQUEST.45A.8.3.4DM-TIMINGACK.45History.46SIST EN 300 396-8-4 V1.1.1:2003
ETSIETSIEN300396-8-4V1.1.1(2001-01)5IntellectualPropertyRightsIPRsessentialorpotentiallyessentialtothepresentdocumentmayhavebeendeclaredtoETSI.TheinformationpertainingtotheseessentialIPRs,ifany,ispubliclyavailableforETSImembersandnon-members,andcanbefoundinETSISR000314:"IntellectualPropertyRights(IPRs);Essential,orpotentiallyEssential,IPRsnotifiedtoETSIinrespectofETSIstandards",whichisavailablefromtheETSISecretariat.LatestupdatesareavailableontheETSIWebserver(http://www.etsi.org/ipr).PursuanttotheETSIIPRPolicy,noinvestigation,includingIPRsearches,hasbeencarriedoutbyETSI.NoguaranteecanbegivenastotheexistenceofotherIPRsnotreferencedinETSISR000314(ortheupdatesontheETSIWebserver)whichare,ormaybe,ormaybecome,essentialtothepresentdocument.ForewordThisEuropeanStandard(Telecommunicationsseries)hasbeenproducedbyETSIProjectTerrestrialTrunkedRadio(TETRA).ThepresentdocumenthadbeensubmittedtoPublicEnquiryasETS300396-8-4.DuringtheprocessingforVoteitwasconvertedintoanEN.Thepresentdocumentispart8ofamulti-partdeliverablecoveringtheTerrestrialTrunkedRadio(TETRA);TechnicalrequirementsforDirectModeOperation(DMO);asidentifiedbelow:Part1:"Generalnetworkdesign";Part2:"Radioaspects";Part3:"MobileStationtoMobileStation(MS-MS)AirInterface(AI)protocol";Part4:"Type1repeaterairinterface";Part5:"Gatewayairinterface";Part6:"Security";Part7:"Type2repeaterairinterface";Part8:"ProtocolImplementationConformanceStatement(PICS)proformaspecification";Part9:"ServiceandDescriptionLanguage(SDL)model";Part10:"ManagedDirectModeOperation(DMO)".NationaltranspositiondatesDateofadoptionofthisEN:22December2000DateoflatestannouncementofthisEN(doa):31March2001DateoflatestpublicationofnewNationalStandardorendorsementofthisEN(dop/e):30September2001DateofwithdrawalofanyconflictingNationalStandard(dow):30September2001SIST EN 300 396-8-4 V1.1.1:2003
ETSIETSIEN300396-8-4V1.1.1(2001-01)6IntroductionToevaluateconformanceofaparticularimplementation,itisnecessarytohaveastatementofwhichcapabilitiesandoptionshavebeenimplementedforatelecommunicationspecification.SuchastatementiscalledanImplementationConformanceStatement(ICS).SIST EN 300 396-8-4 V1.1.1:2003
ETSIETSIEN300396-8-4V1.1.1(2001-01)71ScopeThepresentdocumetprovidestheProtocolImplementationConformanceStatement(PICS)proformaforTETRADirectModeOperation(DMO)MobileStations(MS)connectedtoType2repeater(MS-REP2)andforTETRADirectModeOperationType2repeater(DM-REP2),definedinEN300396-7[1]incompliancewiththerelevantrequirements,andinaccordancewiththerelevantguidancegiveninISO/IEC9646-7[6]andETS300406[4].2ReferencesThefollowingdocumentscontainprovisionswhich,throughreferenceinthistext,constituteprovisionsofthepresentdocument.• Referencesareeitherspecific(identifiedbydateofpublication,editionnumber,versionnumber,etc.)ornon-specific.• Foraspecificreference,subsequentrevisionsdonotapply.• Foranon-specificreference,thelatestversionapplies.[1]ETSIEN300396-7:"TerrestrialTrunkedRadio(TETRA);TechnicalrequirementsforDirectModeOperation(DMO);Part7:Type2repeaterairinterface".[2]ETSIETS300396-3:"TerrestrialTrunkedRadio(TETRA);TechnicalrequirementsforDirectModeOperation(DMO);Part3:MobileStationtoMobileStation(MS-MS)AirInterface(AI)protocol".[3]ETSIEN300396-8-2:"TerrestrialTrunkedRadio(TETRA);TechnicalrequirementsforDirectModeOperation(DMO);Part8:ProtocolImplementationConformanceStatement(PICS)proformaspecification;Sub-part2:Type1repeaterAirInterface(AI)".[4]ETSIETS300406:"MethodsforTestingandSpecification(MTS);Protocolandprofileconformancetestingspecifications;Standardizationmethodology".[5]ISO/IEC9646-1(1994):"Informationtechnology-Opensystemsinterconnection-Conformancetestingmethodologyandframework-Part1:Generalconcepts".[6]ISO/IEC9646-7(1995):"Informationtechnology-Opensystemsinterconnection-Conformancetestingmethodologyandframework-Part7:ImplementationConformanceStatements".[7]ETSIEN300396-4:"TerrestrialTrunkedRadio(TETRA);TechnicalrequirementsforDirectModeOperation(DMO);Part4:Type1repeaterairinterface".3Definitionsandabbreviations3.1DefinitionsForthepurposesofthepresentdocument,thetermsanddefinitionsgiveninEN300396-4[7],ISO/IEC9646-1[5],ISO/IEC9646-7[6]andthefollowingapply.ImplementationConformanceStatement(ICS):statementmadebythesupplierofanimplementationorsystemclaimedtoconformtoagivenspecification,statingwhichcapabilitieshavebeenimplemented.TheICScantakeseveralforms:protocolICS,profileICS,profilespecificICS,informationobjectICS,etc.ICSproforma:document,intheformofaquestionnaire,whichwhencompletedforanimplementationorsystembecomesanICSProtocolICS(PICS):ICSforanimplementationorsystemclaimedtoconformtoagivenprotocolspecificationSIST EN 300 396-8-4 V1.1.1:2003
ETSIETSIEN300396-8-4V1.1.1(2001-01)83.2AbbreviationsForthepurposesofthepresentdocument,thefollowingabbreviationsapply:ICSImplementationConformanceStatementIUTImplementationUnderTestPICSProtocolImplementationConformanceStatementSCSSystemConformanceStatementSUTSystemUnderTest4ConformancetothisPICSproformaspecificationIfitclaimstoconformtothepresentdocument,theactualPICSproformatobefilledinbyasuppliershallbetechnicallyequivalenttothetextofthePICSproformagiveninannexA,andshallpreservethenumbering/namingandorderingoftheproformaitems.APICSwhichconformstothepresentdocumentshallbeaconformingPICSproformacompletedinaccordancewiththeguidanceforcompletiongiveninclauseA.1.SIST EN 300 396-8-4 V1.1.1:2003
ETSIETSIEN300396-8-4V1.1.1(2001-01)9AnnexA(normative):ProtocolICSproforma(PICS)forEN300396-4Notwithstandingtheprovisionsofthecopyrightclauserelatedtothetextofthepresentdocument,ETSIgrantsthatusersofthepresentdocumentmayfreelyreproducethePICSproformainthisannexsothatitcanbeusedforitsintendedpurposesandmayfurtherpublishthecompletedPICS.A.1GuidanceforcompletingthePICSproformaA.1.1PurposesandstructureThepurposeofthisPICSproformaistoprovideamechanismwherebyasupplierofanimplementationoftherequirementsdefinedinEN300396-7[1]mayprovideinformationabouttheimplementationinastandardizedmanner.ThePICSproformaissubdividedintoclausesforthefollowingcategoriesofinformation:• guidanceforcompletingthePICSproforma;• identificationoftheimplementation;• identificationoftheProtocol;• globalstatementofconformance;• identificationoftheroles,MS-REP2orDM-REP2;• MS-REP2layer3protocolpart;• MS-REP2protocollayer2part;• DM-REP2part.A.1.2AbbreviationsandconventionsThePICSproformacontainedinthisannexiscomprisedofinformationintabularforminaccordancewiththeguidelinespresentedinISO/IEC9646-7[6].ItemcolumnTheitemcolumncontainsanumberwhichidentifiestheiteminthetable.ItemdescriptioncolumnTheitemdescriptioncolumndescribesinfreetexteachrespectiveitem(e.g.parameters,timers,etc.).Itimplicitlymeans"issupportedbytheimplementation?".StatuscolumnThefollowingnotations,definedinISO/IEC9646-7[6],areusedforthestatuscolumn:mmandatory-thecapabilityisrequiredtobesupported;ooptional-thecapabilitymaybesupportedornot;n/anotapplicable-inthegivencontext,itisimpossibletousethecapability;xprohibited(excluded)-thereisarequirementnottousethiscapabilityinthegivencontext;SIST EN 300 396-8-4 V1.1.1:2003
ETSIETSIEN300396-8-4V1.1.1(2001-01)10o.iqualifiedoptional-formutuallyexclusiveorselectableoptionsfromaset."i"isanintegerwhichidentifiesauniquegroupofrelatedoptionalitemsandthelogicoftheirselectionwhichisdefinedimmediatelyfollowingthetable;ciconditional-therequirementonthecapability("m","o","x"or"n/a")dependsonthesupportofotheroptionalorconditionalitems."i"isanintegeridentifyingauniqueconditionalstatusexpressionwhichisdefinedimmediatelyfollowingthetable.ReferencecolumnThereferencecolumnmakesreferencetoEN300396-7[1],exceptwhereexplicitlystatedotherwise.SupportcolumnThesupportcolumnshallbefilledinbythesupplieroftheimplementation.Thefollowingcommonnotations,definedinISO/IEC9646-7[6],areusedforthesupportcolumn:Yorysupportedbytheimplementation;Nornnotsupportedbytheimplementation;N/A,n/aor-noanswerrequired(allowedonlyifthestatusisn/a,directlyorafterevaluationofaconditionalstatus).IfthisPICSproformaiscompletedinordertodescribeamultiple-profilesupportinasystem,itisnecessarytobeabletoanswerthatacapabilityissupportedforoneprofileandnotsupportedforanother.Inthatcase,thesuppliershallentertheuniquereferencetoaconditionalexpression,precededby"?"(e.g.?3).Thisexpressionshallbegiveninthespaceforcommentsprovidedatthebottomofthetable.ItusespredicatesdefinedintheSCS,eachofwhichreferstoasingleprofileandwhichtakesthevalueTRUEifandonlyifthatprofileistobeused.EXAMPLE:?3:IFprof1THENYELSENItisalsopossibletoprovideacommenttoananswerinthespaceprovidedatthebottomofthetable.NOTE:AsstatedinISO/IEC9646-7[6],supportforareceivedPDUrequirestheabilitytoparseallvalidparametersofthatPDU.SupportingaPDUwhilehavingnoabilitytoparseavalidparameterisnon-conformant.SupportforaparameteronaPDUmeansthatthesemanticsofthatparameteraresupported.ValuesallowedcolumnThevaluesallowedcolumncontainsthetype,thelist,therange,orthelengthofvaluesallowed.Thefollowingnotationsareused:• rangeofvalues:.example:5.20• listofvalues:,,.,example:2,4,6,8,9example:'1101'B,'1011'B,'1111'Bexample:'0A'H,'34'H,'2F'H• listofnamedvalues:(),(),.,(example:reject(1),accept(2)• length:size(.)example:size(1.8)SIST EN 300 396-8-4 V1.1.1:2003
ETSIETSIEN300396-8-4V1.1.1(2001-01)11ValuessupportedcolumnThevaluessupportedcolumnshallbefilledinbythesupplieroftheimplementation.Inthiscolumn,thevaluesortherangesofvaluessupportedbytheimplementationshallbeindicated.ReferencestoitemsForeachpossibleitemanswer(answerinthesupportcolumn)withinthePICSproformaauniquereferenceexists,used,forexample,intheconditionalexpressions.Itisdefinedasthetableidentifier,followedbyasoliduscharacter"/",followedbytheitemnumberinthetable.Ifthereismorethanonesupportcolumninatable,thecolumnsarediscriminatedbyletters(a,b,etc.),respectively.EXAMPLE1:A.5/4isthereferencetotheanswerofitem4intable5ofannexA.EXAMPLE2:A.6/3bisthereferencetothesecondanswer(i.e.inthesecondsupportcolumn)ofitem3intable6ofannexA.PrerequisitelineAprerequisitelinetakestheform:Prerequisite:.AprerequisitelineafteraclauseortabletitleindicatesthatthewholeclauseorthewholetableisnotrequiredtobecompletedifthepredicateisFALSE.A.1.3InstructionsforcompletingthePICSproformaThesupplieroftheimplementationshallcompletethePICSproformaineachofthespacesprovided.Inparticular,anexplicitanswershallbeentered,ineachofthesupportorsupportedcolumnboxesprovided,usingthenotationdescribedinclauseA.1.2.Ifnecessary,thesuppliermayprovideadditionalcommentsinspaceatthebottomofthetables,orseparatelyonsheetsofpaper.MoredetailedinstructionsaregivenatthebeginningofthedifferentclausesofthePICSproforma.A.2IdentificationoftheimplementationIdentificationoftheImplementationUnderTest(IUT)andthesysteminwhichitresides(theSystemUnderTest(SUT))shouldbefilledinsoastoprovideasmuchdetailaspossibleregardingversionnumbersandconfigurationoptions.Theproductsupplierinformationandclientinformationshouldbothbefillediniftheyaredifferent.ApersonwhocananswerqueriesregardinginformationsuppliedinthePICSshouldbenamedasthecontactperson.A.2.1DateofthestatementA.2.2ImplementationUnderTest(IUT)identificationIUTname:.IUTversion:.SIST EN 300 396-8-4 V1.1.1:2003
ETSIETSIEN300396-8-4V1.1.1(2001-01)12A.2.3SystemUnderTest(SUT)identificationSUTname:.Hardwareconfiguration:.Operatingsystem:.A.2.4ProductsupplierName:.Address:.Telephonenumber:.Facsimilenumber:.E-mailaddress:.Additionalinformation:.A.2.5Client(ifdifferentfromproductsupplier)Name:.Address:.Telephonenumber:.Facsimilenumber:.E-mailaddress:.Additionalinformation:.SIST EN 300 396-8-4 V1.1.1:2003
ETSIETSIEN300396-8-4V1.1.1(2001-01)13A.2.6PICScontactperson(ApersontocontactifthereareanyqueriesconcerningthecontentofthePICS)Name:.Telephonenumber:.Facsimilenumber:.E-mailaddress:.Additionalinformation:.A.3IdentificationoftheProtocolThisPICSproformaappliestothefollowingstandard:EN300396-7[1]:"TerrestrialTrunkedRadio(TETRA);TechnicalrequirementsforDirectModeOperation(DMO);Part7:Type2repeaterairinterface".Thisproformacoverstwolayersoftheprotocolstack,DirectModeCallControl(DMCC)atlayer3andDataLinkLayer(DLL)atlayer2fortheDM-MSoperatingwithatype2repeater(MS-REP2),andonelayeronly(layer2)ofthetype2DM-REPprotocol(DM-REP2).EachofthesepartsisaddressedinadifferentsectionofthepresentPICS.Whensubmittinganimplementationfortest,theimplementerisrequiredtoanswerthequestionsofthesection(s)oftheproformapertainingtothepart(s)oftheprotocolsubmittedtothetest,i.e.theMS-REP2sectionand/ortheDM-REP2section.A.4GlobalstatementofconformanceAreallmandatorycapabilitiesoftheDM-MSforoperationwithatype2DM-REPimplemented?(Yes/No/(n/a))Areallmandatorycapabilitiesofthetype2RepeaterLayer2Protocolimplemented?(Yes/No/(n/a))NOTE:Answering"No"toanyofthesequestionsindicatesnon-conformancetotheProtocolspecification.Non-supportedmandatorycapabilitiesaretobeidentifiedinthePICS,withanexplanationofwhytheimplementationisnon-conforming,onpagesattachedtothePICSproforma.Answering"n/a"toanyofthesequestionsindicatesthatthequestionsrelatedtothatpartdoesnotapply.SIST EN 300 396-8-4 V1.1.1:2003
ETSIETSIEN300396-8-4V1.1.1(2001-01)14A.5RolesThesupplieroftheimplementationshallstatetheroleoftheimplementation,intableA.1.TableA.1:RolesItemRoleReferenceStatusSupport1DM-MSsupportingoperationwithatype2DM-REP(MS-REP2)4.1o.12Type2Repeater(Layer2protocolofaDM-REP2)4.1o.1o.1:Itismandatorytosupportatleastoneoftheseitems.A.6ProtocolsforDM-MSsupportingoperationwithatype2DM-REP(MS-REP2)A.6.1MS-REP2DirectModeCallControl(DMCC)atLayer3ThisclauseisderivedfromclauseA.6ofEN300396-8-2[3]whichcontainsthePICSforaDM-MSsupportingoperationwithatype1repeater(MS-REP1).Onmanyoccasions,referencesaretakenfromthisdocument,tobemorepreciseinthedescriptionoftheconformancerequirements.A.6.1.1DMCCmajorcapabilitiesThesupplieroftheMS-REP2implementationshallstatethesupportoftheimplementationforeachofthefollowingprotocolservices,intableA.2.TableA.2:DMCCservicesPrerequisite:A.1/1--MS-REP2ItemServiceReferencefrom[3]StatusSupport1Circuitmodecall6.2o.22ShortDataService(SDS)6.3o.2o.2:Itismandatorytosupportatleastoneoftheseitems.SIST EN 300 396-8-4 V1.1.1:2003
ETSIETSIEN300396-8-4V1.1.1(2001-01)15A.6.1.2CircuitmodecallThesupplieroftheimplementationshallstatethesupportoftheimplementationforeachofthefollowingcircuitmodecallprotocolfeatures,intableA.3.TableA.3:CircuitmodeprotocolfeaturesPrerequisite:A.2/1--circuitmodecallItemProtocolfeaturesReferencefrom[3]StatusSupport1Groupaddresscallcapability5.2o.32Individualaddresscallcapability5.2o.33Initiatecallset-upwithoutpresencecheck6.2.1.1o4Initiatecallset-upwithpresencecheck6.2.2.1o5Acceptcallset-upwithoutpresencecheck6.2.1.2m6Acceptcallset-upwithpresencecheck6.2.2.2o7Masterendofcalltransmission6.2.4.1c3018Receiveendofcalltransmission6.2.4.2m9Mastercalltermination6.2.4.1,6.2.5.1c30110Receivecalltermination6.2.4.2,6.2.5.2m11Acceptcallpre-emption6.2.4.1,6.2.5.1c30112Initiatepre-emptioninongoingcall6.2.4.2o13Initiateanewcallbypre-emption6.2.6o14Initiatecallchange-over6.2.5.2o15Acceptcallchange-over6.2.5.1c30116Lateentrybycalledparty6.2.3.2o17ReceiveTPNIincallset-up6.2.4.3m18SuppressTPNIincallset-up6.2.4.3o19Receiveinter-MNIcall6.2.4.3m20Initiateinter-MNIcall6.2.4.3oo.3:Itismandatorytosupportatleastoneoftheseitems.c301:IFA.3/3ORA.3/4--Ifinitiationofcallset-upwithorwithoutpresencechecksupportedTHENm--thenmandatoryELSEn/aA.6.1.3Circuitmodecallset-upThesupplieroftheimplementationshallstatethesupportoftheimplementationforeachofthefollowingcircuitmodecallset-upprocedures,intablesA.4toA.5.TableA.4:Circuitmodecallset-upprocedures-GroupcallPrerequisite:A.3/1ANDA.3/3--Initiategroupcallset-upItemSet-upprocedureReferencefrom[3]StatusSupport1Groupcalladdress6.2.1.1m2Callontemporarygroupaddress6.2.1.3oSIST EN 300 396-8-4 V1.1.1:2003
ETSIETSIEN300396-8-4V1.1.1(2001-01)16TableA.5:Circuitmodecallset-upprocedures-IndividualcallPrerequisite:A.3/2--IndividualaddresscallcapabilityItemset-upprocedureReferencefrom[3]StatusSupport1Individualcallwithoutpresencecheck6.2.1.1c5012Individualcallwithpresencecheck6.2.2.1c502c501:IFA.3/3THENoELSEn/a--Ifinitiatecallset-upwithoutpresencecheckthenoptionalc502:IFA.3/4THENmELSEn/a--Ifinitiatecallset-upwithpresencecheckthenmandatoryA.6.1.4CircuitmodeservicesofferedThesupplieroftheimplementationshallstatethesupportoftheimplementationforeachofthefollowingcircuitmodeservices,intableA.6TableA.6:CircuitmodeservicesofferedPrerequisite:A.2/1--circuitmodecallItemCircuitmodeserviceReferencefrom[3]StatusSupport1Circuitmodespeech:5.4o.42Circuitmodedataunprotected:7.25.4o.43Circuitmodedatalowprotection:4.8,N=15.4o.44Circuitmodedatalowprotection:4.8,N=45.4o.45Circuitmodedatalowprotection:4.8,N=85.4o.46Circuitmodedatahighprotection:2.4,N=15.4o.47Circuitmodedatahighprotection:2.4,N=45.4o.48Circuitmodedatahighprotection:2.4,N=85.4o.49Clearmodetransmission5.2o.510Endtoendencryptedtransmission5.2o.511Normalprioritycall5.4m12Highprioritycall5.4o13Pre-emptiveprioritycall5.4o14Emergencypre-emptiveprioritycall5.4o15Recentuserpriorityservice5.4oo.4:Itismandatorytosupportatleastoneoftheseitems.o.5:Itismandatorytosupportatleastoneoftheseitems.A.6.1.5ShortdataservicesThesupplieroftheimplementationshallstatethesupportoftheimplementationforeachofthefollowingshortdataservices,intableA.7.TableA.7:ShortDataServicesPrerequisite:A.2/2--ShortDataServicesItemShortdataserviceReferencefrom[3]StatusSupport1Senddata(note1)6.3.1o.62Receivedata(note2)6.3.2o.63Extendederrorprotection(FCS)6.3.4mNOTE1:CapabilitytooriginateshortdatatransactionasmasterNOTE2:Capabilitytoreceiveshortdatatransactionasslaveo.6:Itismandatorytosupportatleastoneoftheseitems.SIST EN 300 396-8-4 V1.1.1:2003
ETSIETSIEN300396-8-4V1.1.1(2001-01)17A.6.1.6TypeofshortdataserviceThesupplieroftheimplementationshallstatethesupportoftheimplementationforeachofthefollowingtypesofSDSs,intablesA.8toA.12.TableA.8:TypeofshortdataservicePrerequisite:A.2/2--ShortDataServicesItemTypeofshortdataserviceReferencefrom[3]StatusSupport1GroupaddressSDScapability6.3o.72IndividualaddressSDScapability6.3o.73Pre-definedshortdatamessages6.3o.84User-definedshortdatamessages6.3o.85OTAR(note)6.3o.86Enable/disable(note)6.3o.87Additionaladdressing(receive)6.3.3c8018Additionaladdressing(send)6.3.3c802NOTE:ThedetailedPICSproformaforDMOsecurityisdefinedinaseparatePICSproformacoveringsecurityaspects.o.7:Itismandatorytosupportatleastoneoftheseitems.o.8:Itismandatorytosupportatleastoneoftheseitems.c801:IFA.7/2THENmELSEn/a--IfreceiveSDSsupportedthenmandatoryc802:IFA.7/1THENoELSEn/a--IfsendSDSsupportedthenoptionalTableA.9:SendshortdataserviceongroupaddressPrerequisite:A.7/1ANDA.8/1--GroupaddressSDScapabilityItemSDSongroupaddressReferencefrom[3]StatusSupport1Unacknowledgeddataservice6.3mTableA.10:SendshortdataserviceonindividualaddressPrerequisite:A.7/1ANDA.8/2--IndividualaddressSDScapabilityItemSDSonindividualaddressReferencefrom[3]StatusSupport1Unacknowledgeddataservice6.3o.92Acknowledgeddataservice6.3o.93ExtractionofdataifincludedinACK6.3c1001o.9:Itismandatorytosupportatleastoneoftheseitems.c1001:IFA.10/2--IfthesendingofacknowledgedshortdataservicesupportedTHENm--thenmandatoryELSEn/aTableA.11:ReceiveshortdataserviceongroupaddressPrerequisite:A.7/2ANDA.8/1--GroupaddressSDScapabilityItemSDSongroupaddressReferencefrom[3]StatusSupport1Unacknowledgeddataservice6.3mSIST EN 300 396-8-4 V1.1.1:2003
ETSIETSIEN300396-8-4V1.1.1(2001-01)18TableA.12:ReceiveshortdataserviceonindividualaddressPrerequisite:A.7/2ANDA.8/2--IndividualaddressSDScapabilityItemSDSonindividualaddressReferencefrom[3]StatusSupport1Unacknowledgeddataservice6.3o.102Acknowledgeddataservice6.3o.103IncludingdatainACK6.3oo.10:Itismandatorytosupportatleastoneoftheseitems.A.6.1.7DatatransmissionThesupplieroftheimplementationshallstatethesupportoftheimplementationforeachofthefollowingservicesforsendingdata,intableA.13.TableA.13:SendingdataservicesPrerequisite:A.7/1--SenddatausingSDSItemSenddataReferencefrom[3]StatusSupport1Sendshortdataonafreechannel6.3.1.1m2Sendshortdataafterpre-emptionofacircuitmodecall(newcall)6.3.1.2o3Sendshortdatastealingfromcircuitmodetransmission6.3.1.3c13014Sendshortdataafterpre-emptionofacircuitmodecall(ongoingcall)6.3.1.4.1c13025Sendshortdataafterchangeoverofacircuitmodecall6.3.1.4.2c13026Sendshortdataasmasterofacircuitmodecall6.3.1.4.3c1302c1301:IFA.3/3ORA.3/4--IfinitiateCMcallset-upsupportedTHENo--thenoptionalELSEn/ac1302:IFA.2/1--IfCMcallsupportedthenoptionalTHENoELSEn/aA.6.1.8SDSuserdefineddataThesupplieroftheimplementationshallstatethesupportoftheimplementationforeachofthefollowingtypesofSDSs,intableA.14.TableA.14:SDSuserdefineddataPrerequisite:A.8/4--UserdefinedshortdataItemCircuitmodeserviceReferencefrom[3]StatusSupport1Userdefineddata1(16bits)5.4o.112Userdefineddata2(32bits)5.4o.113Userdefineddata3(64bits)5.4o.114Userdefineddata4(upto2047bits)5.4o.11o.11:Itismandatorytosupportatleastoneoftheseitems.SIST EN 300 396-8-4 V1.1.1:2003
ETSIETSIEN300396-8-4V1.1.1(2001-01)19A.6.1.9DMCCPDUsThesupplieroftheimplementationshallstatethesupportoftheimplementationforeachofthefollowingcircuitmodeandSDSPDUs,intablesA.15toA.16.TableA.15:CircuitModecallandpre-emptionPDUsItemPDUReferenceSendingReceivingfromETS300396-3[2]StatusSupportStatusSupport1DM-SETUP9.5.1c1501c15022DM-SETUPPRES9.5.2c1503c15043DM-CONNECT9.5.3c1504c15034DM-DISCONNECT9.5.4c1504c15035DM-CONNECTACK9.5.5c1503c15046DM-OCCUPIED9.5.6c1505c15027DM-RELEASE9.5.7c1505c15028DM-TXCEASED9.5.8c1505c15029DM-TXREQUEST9.5.9c1506c150510DM-TXACCEPT9.5.10c1505c151211DM-PREEMPT9.5.11c1507c151112DM-PREACCEPT9.5.12c1511c151313DM-REJECT9.5.13c1509c151014DM-INFO9.5.14c1508c1502c1501:IFA.3/1ORA.5/1--Ifgroupcallorindividualcallset-upwithoutpresencecheckTHENm--supportedthenmandatoryELSEn/ac1502:IFA.2/1--IfcircuitmodecallsupportedTHENm--thenmandatoryELSEn/ac1503:IFA.5/2--Ifindividualcallset-upwithpresencechecksupportedTHENm--thenmandatoryELSEn/ac1504:IFA.3/6--Ifacceptofcallset-upwithpresencechecksupportedTHENm--thenmandatoryELSEn/ac1505:IFA.3/3ORA.3/4--Ifinitiatecallset-upwithorwithoutpresencechecksupportedTHENm--thenmandatoryELSEn/ac1506:IFA.3/14ORA.13/5--IfCMorSDScallchangeoversupportedTHENm--thenmandatoryELSEn/ac1507:IFA.3/10ORA.3/13--IfinitiationofCMorSDSpre-emptionissupportedORA.13/2ORA.13/4THENm--thenmandatoryELSEn/ac1508:IFA.3/18--IfsendingofTPNIcanbesuppressedthenTHENm--mandatoryelseELSEo--optionalc1509:IFA.3/3ORA.3/4--IfinitiateCMcallsupportedTHENm--thenmandatoryELSEIFA.12/2ORA.12/3--IfreceiveacknowledgedSDSsupportedTHENo--thenoptionalELSEn/ac1510:IFA.2/1OR--IfcircuitmodecallorsendacknowledgedshortdataA.10/2ORA.10/3--supportedTHENm--thenmandatoryELSEn/aSIST EN 300 396-8-4 V1.1.1:2003
ETSIETSIEN300396-8-4V1.1.1(2001-01)20c1511:IFA.3/3OR--IfinitiationofCMorSDScallA.3/4ORA.7/1--supportedTHENm--thenmandatoryELSEn/ac1512:IFA.2/1ORA.13/5--IfcircuitmodecallorsendSDSafterchangeoversupportedTHENm--thenmandatoryELSEn/ac1513:IFA.2/1ORA.13/2--IfcircuitmodecallorsendSDSafterpre-emptionsupportedORA.13/4THENm--thenmandatoryELSEn/aTableA.16:SpecificSDSPDUsPrerequisite:A.2/2--ShortDataServicesItemPDUReferenceSendingReceivingfromdocument[2]StatusSupportStatusSupport1DM-SDSUDATA9.5.15c1601c16032DM-SDSDATA9.5.16c1602c16043DM-SDSACK9.5.17c1604c1602c1601:IFA.9/1ORA.10/1--IfsendingofunacknowledgedSDSwithgrouporindividualaddressTHENm--supportedthenmandatoryELSEn/ac1602:IFA.10/2ORA.10/3--IfsendingofacknowledgeddataservicewithorwithoutdatainTHENm--ACKsupportedthenmandatoryELSEn/ac1603:IFA.11/1ORA.12/1--IfreceivingofunacknowledgedsupportedTHENm--thenmandatoryELSEn/ac1604:IFA.12/2ORA.12/3--IfreceivingofacknowledgeddataservicesupportedTHENm--thenmandatoryELSEn/aSIST EN 300 396-8-4 V1.1.1:2003
ETSIETSIEN300396-8-4V1.1.1(2001-01)21A.6.1.10DMCCconstantsThesupplieroftheimplementationshallstatethesupportoftheimplementationforeachofthefollowingDMCCconstants,intableA.17.TableA.17:DMCCconstantsItemConstantsReferencefrom[3]StatusSupportValuerangesAllowedSupported1DN303--DM-SETUPPRES--retriesA.2c17011.32DN314--DM-SDSUDATA--retriesA.2c17021.63DN315--DM-SDSDATA--retrieson--negativeresponseA.2c17032.64DN316--DM-SDSDATA--retriesonno--responseA.2c17031.45DN304--DM-SETUPorDM---SETUPPRES--retriesonDM---REP2linkfailureA.2c17041.36DN317--DM-SDSDATAor--DM-SDSUDATA--retriesonDM---REP2linkfailureA.2c17051.3c1701:IFA.5/2THENmELSEn/a--Ifcallset-upwithpresencechecksupportedthen--mandatoryc1702:IFA.9/1ORA.10/1--IfunacknowledgedSDSsupportedforTHENmELSEn/a--grouporindividualaddressthenmandatoryc1703:IFA.10/2ORA.10/3--IfacknowledgedSDSsupportedwithorwithoutTHENmELSEn/a--datainACKthenmandatoryc1704:IFA.2/3ORA.2/4--Ifinitiatecallset-upwithoutpresenceORwithpresencecheckTHENmELSEn/a--thenmandatoryc1705:IFA.6/1THENm--IfSendDatathenmandatoryELSEn/aSIST EN 300 396-8-4 V1.1.1:2003
ETSIETSIEN300396-8-4V1.1.1(2001-01)22A.6.1.11DMCCtimersThesupplieroftheimplementationshallstatethesupportoftheimplementationforeachofthefollowingDMCCtimers,intableA.18.TableA.18:DMCCtimersItemTimerReferencefrom[3]StatusSupportValuesDefaultSupported1DT303--WaitDM---SETUP--PRES--responseA.1c1801250--mSec2DT307--WaitDM---CONNECT--ACKA.1c1802350--mSec3DT311--Call--transaction--timeA.1c1803300--Sec4DT314--SDSfailure--timerA.1c1804500--mSec5DT316--WaitDM---SDSDATA--responseA.1c1805400--mSecc1801:IFA.3/4--Ifinitiationofcallset-upwithpresencechecksupportedTHENm--thenmandatoryELSEn/ac1802:IFA.3/6--Ifacceptcallset-upwithpresencechecksupportedTHENm--thenmandatoryELSEn/ac1803:IFA.3/3ORA.3/4--IfinitiateCMcallset-upsupportedTHENm--thenmandatoryELSEn/ac1804:IFA.7/1--IfSDSsenddatasupportedTHENm--thenmandatoryELSEn/ac1805:IFA.10/2ORA.10/3--IfacknowledgedSDSsupportedwithorwithoutTHENm--datainACK.thenmandatoryELSEn/aSIST EN 300 396-8-4 V1.1.1:2003
ETSIETSIEN300396-8-4V1.1.1(2001-01)23A.6.2MS-REP2Datalinklayer(DLL)atLayer2A.6.2.1MS-REP2MACfeaturesThesupplieroftheimplementationshallstatethesupportoftheimplementationforeachofthefollowingMS-REP2MACfeatures,intableA.19.TableA.19:MS-REP2MACfeaturesPrereq
...