Safety of household and similar electrical appliances - Interpretations related to European Standards within the scope of CENELEC/TC 61

This report contains interpretations related to the European  Standards within the scope of CENELEC/TC 61, taken during  meetings.

Varnost gospodinjskih in podobnih električnih aparatov – Razlage v zvezi z evropskimi standardi s področja CENELEC/TC 61

General Information

Status
Withdrawn
Publication Date
31-Mar-2004
Withdrawal Date
11-Apr-2023
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
12-Apr-2023
Due Date
05-May-2023
Completion Date
12-Apr-2023

Relations

Buy Standard

Technical report
TP CLC/TR 50417:2004
English language
35 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST-TP CLC/TR 50417:2004
01-april-2004
9DUQRVWJRVSRGLQMVNLKLQSRGREQLKHOHNWULþQLKDSDUDWRY±5D]ODJHY]YH]L]
HYURSVNLPLVWDQGDUGLVSRGURþMD&(1(/(&7&
Safety of household and similar electrical appliances - Interpretations related to
European Standards within the scope of CENELEC/TC 61
Ta slovenski standard je istoveten z: CLC/TR 50417:2003
ICS:
13.120
97.030
SIST-TP CLC/TR 50417:2004 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

TECHNICAL REPORT CLC/TR 50417
RAPPORT TECHNIQUE
TECHNISCHER BERICHT December 2003

Replaces R061-001:2000


English version


Safety of household and similar electrical appliances –
Interpretations related to European Standards
within the scope of CENELEC/TC 61












This Technical Report was approved by CENELEC on 2003-10-11.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic,
Denmark, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Lithuania, Luxembourg, Malta,
Netherlands, Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: rue de Stassart 35, B - 1050 Brussels


© 2003 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.

Ref. No. CLC/TR 50417:2003 E

---------------------- Page: 2 ----------------------

CLC/TR 50417:2003 - 2 -
Foreword

At the Delft meeting of the Technical Committee CENELEC TC 61 in May 2001, it was decided to revise
R061-001:2000, Interpretations related to European Standards within the scope of CENELEC TC 61.

A draft, document CLC/TC 61(SEC)1356, was discussed at the Kista meeting in May 2002, when it was
decided to request authorization to publish from the CENELEC Technical Board.

The draft was circulated for consultation at national level and voting and was approved by CENELEC as
Technical Report CLC/TR 50417 on 2003-10-11.

This Technical Report includes all the interpretations agreed up to the Brussels meeting of TC 61 in
November 2002. However, some interpretations included in R061-001 that have now been taken into
account in the relevant standard have been withdrawn. Interpretations dealing with EN 60335-1:1988 and its
associated parts 2 have not been maintained.

Interpretations relating to a particular standard are listed together, the Parts 2 of EN 60335 being associated
with the appropriate edition of Part 1. For each standard, the interpretations are listed in the order of clauses
and subclauses. Each interpretation is identified by
- the place and date of the meeting when it was agreed,
- the document number of the minutes of the meeting,
- the number of the reference document, when applicable.
_______________

---------------------- Page: 3 ----------------------

- 3 - CLC/TR 50417:2003
Contents
EN 50088:1996 Safety of electric toys 4
EN 50165:1997 Electrical equipment of non-electric heating appliances 5

EN 60335-1:1994 and related standards
EN 60335-1:1994 General requirements 6
EN 60335-2-2:1995 Vacuum cleaners and water suction cleaning appliances 9
EN 60335-2-3:1995 Electric irons 10
EN 60335-2-5:1995 Dishwashers 11
EN 60335-2-6:1999 Cooking ranges, hobs and ovens 12
EN 60335-2-8:1995 Shavers, hair clippers, etc. 13
EN 60335-2-9:1995 Toasters, grills, etc. 14
EN 60335-2-13:1995 Deep fat fryers, frying pans and similar appliances 15
EN 60335-2-14:1996 Electric kitchen machines 16
EN 60335-2-15:1996 Appliances for heating liquids 17
EN 60335-2-23:1996 Appliances for skin or hair care 18
EN 60335-2-24:1999 Refrigerators, food freezers and ice makers 19
EN 60335-2-27:1997 Appliances for skin exposure to ultraviolet and infrared radiation 20
EN 60335-2-41:1996 Electric pumps for liquids having a temperature not exceeding 35 °C 21
EN 60335-2-44:1997 Ironers 22
EN 60335-2-52:1996 Oral hygiene appliances 23
EN 60335-2-58:1997 Commercial electric dishwashers 24
EN 60335-2-61:1996 Storage room heaters 25
EN 60335-2-71:1995 Heating appliances for breeding and rearing animals 26
EN 60335-2-72:1998 Automatic machines for floor treatment 27
EN 60335-2-78:1997 Outdoor barbecues 28
EN 60335-2-81:1997 Foot warmers 29
EN 60335-2-97:2000 Drives for rolling shutters. 30

EN 60335-1:2002 and related standards
EN 60335-1:2002 General requirements 31
EN 60335-2-6:2003 Cooking ranges, hobs and ovens 32
EN 60335-2-8:2003 Shavers, hair clippers, etc. 33
EN 60335-2-9:2003 Toasters, grills, etc. 34
EN 60335-2-52:2003 Oral hygiene appliances 35

---------------------- Page: 4 ----------------------

CLC/TR 50417:2003 - 4 -
EN 50088:1996 Safety of electric toys

Subclause 9.8.2 Brussels, November 2002, CLC/TC(SEC)1403

Short-circuiting of the low-power circuit is only carried out if the toy contains other circuits having higher
power.


Annex I in amendment A3:2002, Clause 20 Brussels, November 2002, CLC/TC(SEC)1403

The light emission of the LEDs will increase when the power to the LEDs is increased e.g. during fault
conditions. If the maximum current to the LEDs under abnormal conditions is measured or calculated in the
toy under the worst conditions, testing of the LED in the toy under different abnormal conditions can be
avoided and a data sheet can be used.


Annex I in amendment A3:2002, Clause 20 Brussels, November 2002, CLC/TC(SEC)1403

In order to carry out the laser radiation test, it may be necessary to detach parts of the toy, including the
enclosure, even if they have not become detached or broken during the preconditioning test in 5.15.

---------------------- Page: 5 ----------------------

- 5 - CLC/TR 50417:2003
EN 50165:1997 Electrical equipment of non electric heating appliances

Subclause 15.2  Fehraltorf, October 1997, CLC/TC 61(SEC)1162
  CLC/TC 61(ES)59

According to the last paragraph of 15.2 of EN 60335-1:1994, traces of water inside the appliance are allowed
if no reduction of creepage distances and clearances below the values of 29.1 are produced and the
appliance withstands the dielectric strength test of 16.3.

---------------------- Page: 6 ----------------------

CLC/TR 50417:2003 - 6 -
EN 60335-1:1994 General requirements

General  Dublin, May 1995, CLC/TC 61(SEC)1027
  CLC/TC 61(FR)292

In class II constructions of appliances it is not allowed to reverse the basic and the supplementary insulation.


General Copenhagen, May 1996, CLC/TC 61(SEC)1075
  CLC/TC 61(SEC)1000

For testing motor capacitors in appliances under the scope of EN 60335, document IEC 61/1055/CD should
be used.


General Athens, November 1996, CLC/TC 61(SEC)1098
  CLC/TC 61(SEC)1087

The mass of the appliance is to be considered with the empty appliance, if nothing is said in the particular
standard or for a particular clause.


General Brussels, May 1998, CLC/TC61(SEC)1185

Controls are considered to comply with EN 60730 if they complied with the previous relevant standard before
the dow specified in EN 60730, and may be used in an appliance until the end of the certification period.

NOTE  Controls will also have to comply with the applicable requirements of EN 60335 series standards.


General Kristiansand, June 2000, CLC/TC 61(SEC)1287

The word “similar” in the title “Toxicity and similar hazards” means other hazards, which may be applicable
but not covered by the standard.


General Brussels, October 2000, CLC/TC 61(SEC)1302

Concerning the use of socket-outlets on appliances, those should be of the appropriate type as specified in
IEC 60083:1997 for the relevant countries.


Clause 1 Naples, November 1998, CLC/TC61(SEC)1218

The scope of EN 60335-1:1994 is meant to include the safety of operators which are instructed to operate
the machine, but which are non electrical experts.


Subclause 15.1.2 Copenhagen, May 1996, CLC/TC 61(SEC)1075
  CLC/TC 61(SE)351

Parts which are to be removed in accordance with the instructions for use and which can be removed only
with the aid of a tool, shall not be removed, only for the purpose of the test of 15.1.2.


Subclause 19.13 Brussels, November 2002, CLC/TC 61(SEC)1403
  CLC/TC 61(IT)258

In general, creepage distances and clearances are not measured during and after the tests of Clause 19.

---------------------- Page: 7 ----------------------

- 7 - CLC/TR 50417:2003
EN 60335-1:1994 General requirements

Subclause 22.33  Edinburgh, May 1997, CLC/TC 61(SEC)1127
  CLC/TC 61(SE)393

Add the following note:

NOTE 2  An air layer is not considered sufficient as one of the layers of double insulation, if it is likely that the air layer could be bridged
by leaking liquid".


Subclause 22.42 Athens, November 1996, CLC/TC 61(SEC)1098
  CLC/TC 61(AT)260

Concerning Y2 capacitors used as protective impedance, the following applies for bridging insulations:

a) Two Y2 capacitors (voltage proof 1 500 V, Not accepted.
peak impulse 5 kV); Acceptance for two Y2 capacitors
combination Y2 (basic insulation) + with voltage proof 2 500 V only
Y2 (supplementary insulation)

b) Combination Y1 (basic insulation) + Accepted for Y2 capacitors with
Y2 (supplementary insulation) voltage proof 2 500 V only

c) Combination Y2 (basic insulation) Accepted (idem b)
+ Y1 (supplementary insulation)

d) Combination of three Y2 capacitors in series Not accepted


Subclause 24.1.1  Dublin, May 1995, CLC/TC 61(SEC)1027
  CLC/TC 61(SEC)995

Miniature fuses with other ratings or dimensions than those in EN 60127 can be accepted under the following
conditions:

- It shall not be possible to change the fuse without removing a cover with the use of a tool.

- The fuse and the fuseholder shall be marked to ensure correct replacement.

- The fuse shall be checked in the appliance; 10 samples shall break reliably under fault conditions.


Subclause 24.1.2, note 2 Oslo, April 1994, CLC/TC 61(SEC)972

The switching part of an automatic control (or programmer) with an off position is considered as a switch. An
endurance test is only necessary if such a switch is required by the standard.


Subclause 25.7 Delft, May 2001, CLC/TC 61(SEC)1330

The words « shall not be lighter than » means that any heavier standardized cord can be used.


Subclause 25.22 Paris, November 2001, CLC/TC 61(SEC)1349
  CLC/TC 61(SEC)1334

Replace the second dashed item by:

- be located so that the connector can be inserted into the correct engagement position without difficulty
and that improper engagement is not readily possible;

---------------------- Page: 8 ----------------------

CLC/TR 50417:2003 - 8 -
EN 60335-1:1994 General requirements (end)

Subclause 26.10 Pamplona, June 1999, CLC/TC 61(SEC)1244
  CLC/TC 61(DK)123

This subclause does not apply to earth terminals.


Subclause 30.2 Pettenasco, September 1992, CLC/TC 61(SEC)869

"not likely to be ignited" belongs to decorative trims, knobs and other parts.


Annex ZD Kristiansand, June 2000, CLC/TC 61(SEC)1287
  CLC/TC 61(SEC)1257

Clause 29 has to be mentioned instead of 29.1 with regard to distances, because 29.2 (distance through
insulation) is also involved.

---------------------- Page: 9 ----------------------

- 9 - CLC/TR 50417:2003
EN 60335-2-2:1995 Vacuum cleaners and water suction cleaning appliances

Subclauses 25.8 and 25.23 Edinburgh, May 1997, CLC/TC 61(SEC)1127
  CLC/TC 61(FR)336

For vacuum cleaners with motorized heads with the interconnection cord fixed in the hose in a spiral form
with a length superior to 2 m, the limit in length does not apply in as far as all other requirements of the
standard are fulfilled, namely for the hose.

---------------------- Page: 10 ----------------------

CLC/TR 50417:2003 - 10 -
EN 60335-2-3:1995 Electric irons

Subclause 11.8 Edinburgh, May 1997, CLC/TC 61(SEC)1127
  CLC/TC 61(FR)323

For textile material a limit of 80 K is allowed.


Subclause 11.8 Brussels, October 2000, CLC/TC 61(SEC)1302
  CLC/TC 61(SEC)1297

The limit of 60 K for supply cords without T-marking is applicable only to cables connected to the iron and not
to supply cables connected to the separate boiler or water container.


Subclauses 24.4 and 24.5 Athens, November 1996, CLC/TC 61(SEC)1098
  TC 61/IEC 60335-2-3(1993) IS 01

Add:

NOTE  This requirement is not applicable to the connection between the iron and the stand of cordless irons.


Subclause 25.7 Oslo, April 1994, CLC/TC 61(SEC)972

The following feature can be taken into account:

Cords to HD 22.14 S1 can be used on irons for type X attachments with specially prepared cord and type Y
and Z attachments.


Subclause 29.1 Dublin, May 1995, CLC/TC 61(SEC)1027
  CLC/TC 61(NL)407

Not every part of an iron can be regarded as not protected against deposition of dust. The micro environment
has to be taken into account, so each construction has to be considered carefully, taking into account note 2
to Table 13, stating that hermetic sealing is not required.


Subclause 30.3 Oslo, April 1994, CLC/TC 61(SEC)972
  CLC/TC 61(NL)370

The following has to be taken into account:

Insulating materials are considered to be used under normal conditions.

---------------------- Page: 11 ----------------------

- 11 - CLC/TR 50417:2003
EN 60335-2-5:1995 Dishwashers

General Amsterdam, September 1995, CLC/TC 61(SEC)1055
  CLC/TC 61(IT)207

Both types of detergents quoted in IEC 60436:1981 and in its amendment 3:1994 "Methods of measuring the
performance of electric dishwashers" can be used.

---------------------- Page: 12 ----------------------

CLC/TR 50417:2003 - 12 -
EN 60335-2-6:1999 Cooking ranges, hobs and ovens

Subclause 11.102 Brussels, November 2002, CLC/TC 61(SEC)1403
  CLC/TC 61(SEC)1380

When operating the grill in the oven, the grill is operated under normal operation.


Subclause 20.101 Brussels, October 2000, CLC/TC 61(SEC)1302
  CLC/TC 61(SEC)1297

The stability test has to be carried out with the oven placed in its intended position.


Clause 21 Delft, May 2001, CLC/TC 61(SEC)1330
  CLC/TC 61(SEC)1305

Referring to NOTE 1, hobs having a complete surface in one piece are tested according to 21.102 and
Part 1.

---------------------- Page: 13 ----------------------

- 13 - CLC/TR 50417:2003
EN 60335-2-8:1995 Shavers, hair clippers, etc.

Subclause 2.2.9 Copenhagen, May 1996, CLC/TC 61(SEC)1075
  CLC/TC 61(DE)496

The following text shall be added to the note.

If the necessary adjustment of the blades on adjustable shearing or clipping heads is not po
...

Questions, Comments and Discussion