Radio-frequency connectors - Part 44: Sectional specification for series SMP push-on radio-frequency coaxial connectors

This part of IEC 61169 which is a sectional specification (SS) provides information and rules for preparation of detail specification of SMP series push-on RF coaxial connectors together with the pro-forma blank detail specification. The SMP push-on series connectors with characteristic impedance of 50 O are used with RF cables or micro-strips in microwave, telecommunication, wireless and other fields. The operating frequency limit is up to 40 GHz. It also prescribes mating face dimensions for general purpose connectors - grade 1, dimensional details of standard test connectors - grade 0, gauging information and tests selected from IEC 61169-1, applicable to all detail specifications relating to series SMP RF connectors. This specification indicates the recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H.

Hochfrequenz-Steckverbinder - Teil 44: Rahmenspezifikation für koaxiale HF-Steckverbinder der SMP-Serie

Connecteurs pour fréquences radioélectriques -- Partie 44: Spécification intermédiaire relative aux connecteurs coaxiaux pour fréquences radioélectriques glissants, série SMP

La CEI 61169-44:2012 est une spécification intermédiaire qui fournit des informations et des règles en vue de l'établissement de la spécification particulière des connecteurs coaxiaux RF glissants série SMP, ainsi que la spécification particulière cadre pro-forma.
Les connecteurs glissants série SMP avec impédance caractéristique de 50 Ω sont utilisés avec des câbles RF ou des microrubans dans les domaines de l'hyperfréquence, des télécommunications, des liaisons sans-fil et autres domaines. La limite de fréquence de fonctionnement est inférieure ou égale à 40 GHz. Elle prescrit également les dimensions d'interface d'accouplement pour des connecteurs d'usage général - classe 1, les détails dimensionnels des connecteurs d'essai normalisés - classe 0, les informations de calibrage et les essais choisis dans la CEI 61169-1, applicables à toutes les spécifications particulières ayant trait aux connecteurs RF, série SMP. La présente spécification indique les caractéristiques de performance recommandées à prendre en compte pour la rédaction d'une spécification particulière, et elle couvre les programmes d'essais et les exigences de contrôle pour les niveaux d'assurance qualité M et H.

Radiofrekvenčni konektorji - 44. del: Področna specifikacija za serijo koaksialnih natičnih radiofrekvenčnih SMP konektorjev

Ta del standarda IEC 61169, ki je področna specifikacija (SS), podaja informacije in določa pravila za pripravo podrobne specifikacije za serijo koaksialnih natičnih radiofrekvenčnih SMP konektorjev skupaj s pro forma okvirno podrobno specifikacijo. Natični SMP konektorji s karakteristično impendanco 50 O se uporabljajo z radiofrekvenčnimi kabli ali mikrotrakovi pri mikrovalovanju, telekomunikacijah, v brezžičnih omrežjih in na drugih področjih. Omejitev frekvenčnega območja delovanja je do 40 GHz. Prav tako prepisuje prednje dimenzije stikanja za konektorje za splošni namen – tip 1, podrobnosti o dimenziji standardnih preskusnih konektorjev – tip 0, merjenje informacij in preskuse, izbrane iz standarda IEC 61169-1, ki se uporabljajo za vse podrobne specifikacije v zvezi z radiofrekvenčnimi SMP konektorji. Ta specifikacija določa priporočene lastnosti, ki jih je treba upoštevati pri sestavljanju podrobne specifikacije ter zajema urnike preskusov in zahteve za pregled za ravni vrednotenja M in H.

General Information

Status
Published
Publication Date
11-Sep-2013
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
28-Aug-2013
Due Date
02-Nov-2013
Completion Date
12-Sep-2013

Buy Standard

Standard
EN 61169-44:2013
English language
34 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 61169-44:2013
01-oktober-2013
5DGLRIUHNYHQþQLNRQHNWRUMLGHO3RGURþQDVSHFLILNDFLMD]DVHULMRNRDNVLDOQLK
QDWLþQLKUDGLRIUHNYHQþQLK603NRQHNWRUMHY
Radio-frequency connectors - Part 44: Sectional specification for series SMP push-on
radio-frequency coaxial connectors
Hochfrequenz-Steckverbinder - Teil 44: Rahmenspezifikation für koaxiale HF-
Steckverbinder der SMP-Serie
Connecteurs pour fréquences radioélectriques -- Partie 44: Spécification intermédiaire
relative aux connecteurs coaxiaux pour fréquences radioélectriques glissants, série SMP
Ta slovenski standard je istoveten z: EN 61169-44:2013
ICS:
33.120.30 5DGLRIUHNYHQþQLNRQHNWRUML R.F. connectors
5)
SIST EN 61169-44:2013 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 61169-44:2013

---------------------- Page: 2 ----------------------

SIST EN 61169-44:2013

EUROPEAN STANDARD
EN 61169-44

NORME EUROPÉENNE
June 2013
EUROPÄISCHE NORM

ICS 33.120.30


English version


Radio-frequency connectors -
Part 44: Sectional specification for series SMP push-on radio-frequency
coaxial connectors
(IEC 61169-44:2012)


Connecteurs pour fréquences Hochfrequenz-Steckverbinder -
radioélectriques - Teil 44: Rahmenspezifikation für koaxiale
Partie 44: Spécification intermédiaire HF-Steckverbinder der SMP-Serie mit
relative aux connecteurs coaxiaux pour Push-on-Einrastmechanismus
fréquences radioélectriques glissants, (IEC 61169-44:2012)
série SMP
(CEI 61169-44:2012)





This European Standard was approved by CENELEC on 2013-01-16. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the CEN-CENELEC Management Centre or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the CEN-CENELEC Management Centre has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany,
Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland,
Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Management Centre: Avenue Marnix 17, B - 1000 Brussels


© 2013 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61169-44:2013 E

---------------------- Page: 3 ----------------------

SIST EN 61169-44:2013
EN 61169-44:2013 - 2 -

Foreword
The text of document 46F/184/CDV, future edition 1 of IEC 61169-44, prepared by SC 46F, "R.F. and
microwave passive components", of IEC TC 46, "Cables, wires, waveguides, R.F. connectors, R.F. and
microwave passive components and accessories" was submitted to the IEC-CENELEC parallel vote and
approved by CENELEC as EN 61169-44:2013.
The following dates are fixed:
(dop) 2013-12-14
• latest date by which the document has
to be implemented at national level by
publication of an identical national
standard or by endorsement
• latest date by which the national (dow) 2016-01-16
standards conflicting with the

document have to be withdrawn

Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such patent
rights.
Endorsement notice
The text of the International Standard IEC 61169-44:2012 was approved by CENELEC as a European
Standard without any modification.

---------------------- Page: 4 ----------------------

SIST EN 61169-44:2013
- 3 - EN 61169-44:2013
Annex ZA
(normative)

Normative references to international publications
with their corresponding European publications

The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.

NOTE  When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.

Publication Year Title EN/HD Year

IEC 61169-1 1992 Radio-frequency connectors - EN 61169-1 1994
+ A1 1996 Part 1: Generic specification - General + A1 1996
+ A2 1997 requirements and measuring methods + A2 1997

---------------------- Page: 5 ----------------------

SIST EN 61169-44:2013

---------------------- Page: 6 ----------------------

SIST EN 61169-44:2013




IEC 61169-44

®

Edition 1.0 2012-12




INTERNATIONAL



STANDARD








colour

inside










Radio-frequency connectors –

Part 44: Sectional specification for series SMP push-on radio-frequency coaxial

connectors


























INTERNATIONAL

ELECTROTECHNICAL

COMMISSION

PRICE CODE
V


ICS 33.120.30 ISBN 978-2-83220-565-5



  Warning! Make sure that you obtained this publication from an authorized distributor.


® Registered trademark of the International Electrotechnical Commission

---------------------- Page: 7 ----------------------

SIST EN 61169-44:2013
– 2 – 61169-44 © IEC:2012(E)
CONTENTS
FOREWORD . 4
1 Scope . 6
2 Normative references . 6
3 Mating face and gauge information . 7
3.1 Dimensions – General connectors – Grade 1 . 7
3.1.1 Connector with pin-centre contact . 7
3.1.2 Connector with socket-centre contact . 10
3.2 Gauges . 11
3.2.1 Gauge pin for socket-centre contact . 11
3.2.2 Gauge for outer contact of connector with socket-centre contact . 12
3.3 Dimensions – standard test connectors – grade 0. 16
3.3.1 Connector with pin-centre contact . 16
3.3.2 Connector with socket-centre contact . 18
4 Quality assessment procedure . 19
4.1 General . 19
4.2 Rating and characteristics (see Clause 6 of IEC 61169-1) . 19
4.3 Test schedule and inspection requirements-Acceptance tests . 23
4.3.1 Periodic tests. 23
4.4 Procedures . 25
4.4.1 Quality conformance inspection . 25
4.4.2 Qualification approval and its maintenance . 25
5 Instructions for preparation of detail specifications . 25
5.1 General . 25
5.2 Identification of the component . 25
5.3 Performance . 26
5.4 Marking, ordering information and related matters . 26
5.5 Selection of tests, test conditions and severities . 26
5.6 Blank detail specification pro-forma for series SMP connectors . 27

Figure 1 – Connector with pin-centre contact – Limited detent and full detent (for
dimensions and notes, see Table 1) . 7
Figure 2 – Connector with pin- centre contact – Smooth bore (for dimensions and
notes, see Table 2) . 8
Figure 3 – Connector with pin- centre contact – Catchers mit (for dimensions and
notes, see Table 3) . 9
Figure 4 – Connector with socket-centre contact (for dimensions and notes, see Table
4) . 10
Figure 5 – Gauge pin for socket-centre contact (for dimensions and notes, see Table 5) . 11
Figure 6 – Gauge with limited detent for outer contact of connector with socket-outer
contact (for dimensions and notes, see Table 6) . 12
Figure 7 – Gauge pin – Full detent for outer contact of connector with socket-centre
(for dimensions and notes, see Table 7) . 13
Figure 8 – Gauge pin – Smooth bore for outer contact of connector with socket-centre
(for dimensions and notes, see Table 8) . 15
Figure 9 – Connector with pin- centre contact – Limited detent and full detent (for
dimensions and notes, see Table 9) . 16

---------------------- Page: 8 ----------------------

SIST EN 61169-44:2013
61169-44 © IEC:2012(E) – 3 –
Figure 10 – Connector with pin- centre contact – Smooth bore (for dimensions and
notes, see Table 10) . 17
Figure 11 – Connector with socket-centre contact (for dimensions and notes, see
Table 11) . 18

Table 1 – Dimensions of connector with pin-centre contact – Limited detent and full
detent . 7
Table 2 – Dimensions of connector with pin-centre contact – Smooth bore . 8
Table 3 – Dimensions of connector with pin-centre contact – Catchers mit . 9
Table 4 – Dimensions of connector with socket-centre contact . 10
Table 5 – Dimensions of gauge pin for socket-centre contact . 11
Table 6 – Gauge with limited detent for outer contact of connector with socket-outer
contact . 12
Table 7 – Gauge pin – Full detent for outer contact of connector with socket-centre . 14
Table 8 – Gauge pin – Smooth bore for outer contact of connector with socket-centre . 15
Table 9 – Dimensions of connector with pin-centre contact – Limited detent and full
detent . 16
Table 10 – Dimensions of connector with pin-centre contact – Smooth bore . 17
Table 11 – Dimensions of connector with socket-centre contact . 18
Table 12 – Rating and characteristics . 19
Table 13 – Acceptance tests . 23
Table 14 – Periodic tests . 24

---------------------- Page: 9 ----------------------

SIST EN 61169-44:2013
– 4 – 61169-44 © IEC:2012(E)
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________

RADIO-FREQUENCY CONNECTORS –

Part 44: Sectional specification for series SMP
push-on radio-frequency coaxial connectors


FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61169-44 has been prepared by subcommittee 46F: R.F. and
microwave passive components, of IEC technical committee 46: Cables, wires, waveguides,
R.F. connectors, R.F. and microwave passive components and accessories.
This first edition cancels and replaces IEC/PAS 61169-44, published in 2010, of which it
constitutes a minor revision. The only change is that the PAS has been changed into an
International Standard.

---------------------- Page: 10 ----------------------

SIST EN 61169-44:2013
61169-44 © IEC:2012(E) – 5 –
The text of this standard is based on the following documents:
CDV Report on voting
46F/184/CDV 46F/194/RVC

Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
A list of all parts of the IEC 61169 series, published under the general title Radio-frequency
connectors, can be found on the IEC website.
The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
A bilingual version of this publication may be issued at a later date.

IMPORTANT – The 'colour inside' logo on the cover page of this publication indicates
that it contains colours which are considered to be useful for the correct
understanding of its contents. Users should therefore print this document using a
colour printer.

---------------------- Page: 11 ----------------------

SIST EN 61169-44:2013
– 6 – 61169-44 © IEC:2012(E)
RADIO-FREQUENCY CONNECTORS –

Part 44: Sectional specification for series SMP
push-on radio-frequency coaxial connectors



1 Scope
This part of IEC 61169 which is a sectional specification (SS) provides information and rules
for preparation of detail specification of SMP series push-on RF coaxial connectors together
with the pro-forma blank detail specification.
The SMP push-on series connectors with characteristic impedance of 50 Ω are used with RF
cables or micro-strips in microwave, telecommunication, wireless and other fields. The
operating frequency limit is up to 40 GHz.
It also prescribes mating face dimensions for general purpose connectors – grade 1,
dimensional details of standard test connectors – grade 0, gauging information and tests
selected from IEC 61169-1, applicable to all detail specifications relating to series SMP RF
connectors.
This specification indicates the recommended performance characteristics to be considered
when writing a detail specification and it covers test schedules and inspection requirements
for assessment levels M and H.
NOTE Metric dimension are original dimensions.
All undimensioned pictorial configurations are for reference purpose only.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and
are indispensable for its application. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any
amendments) applies.
IEC 61169-1:1992, Radio-frequency connectors – Part 1: Generic specification – General
1
requirements and measuring methods
Amendment 1:1996
Amendment 2:1997

—————————

1
There exists a consolidated edition 1.2 (1998) that comprises IEC 61169-1:1992, its Amendment 1:1996 and its
Amendment 2:1997.

---------------------- Page: 12 ----------------------

SIST EN 61169-44:2013
61169-44 © IEC:2012(E) – 7 –
3 Mating face and gauge information
3.1 Dimensions – General connectors – Grade 1
3.1.1 Connector with pin-centre contact
3.1.1.1 Connector with pin-centre contact – Limited detent and full detent

Note 1
k l
m
Note 3
e
h
f
g
i
IEC  2430/12

Figure 1 – Connector with pin-centre contact – Limited detent and full detent
(for dimensions and notes, see Table 1)
Table 1 – Dimensions of connector with pin-centre contact –
Limited detent and full detent
Ref. mm Notes
Min. Max.
a 3,53 3,68
b 3,15 3,20
c 3,02 3,07 Limited detent
2,92 2,97 Full detent
d 0,38 0,41
e Angle
30° ± 1°
f 0,84 0,94
g 0,52 0,60
h Angle
32° ± 1°
i 2,74 2,84
k 1,14 1,40
l 0,08 0,20
m 40° 50° Angle
n — —

NOTE 1 Mechanical and electrical reference plane.
NOTE 2 The diameter is chosen to meet the nominal impedance of 50 Ω and electrical and
mechanical requirements.
NOTE 3 Spherical or chamfered.
∅n
Note 2
∅d
∅c
∅b
∅a

---------------------- Page: 13 ----------------------

SIST EN 61169-44:2013
– 8 – 61169-44 © IEC:2012(E)
3.1.1.2 Connector with pin-centre contact – Smooth bore

Note 1
l
k
m
Note 3
h
f
i
IEC  2431/12

Figure 2 – Connector with pin- centre contact – Smooth bore
(for dimensions and notes, see Table 2)

Table 2 – Dimensions of connector with pin-centre contact – Smooth bore
Ref. mm Notes
Min. Max.
a 3,53 3,68
b 3,15 3,20
d 0,38 0,41
f 0,84 0,94
h 32° ± 1° Angle
i 2,74 2,84
k 1,14 1,40
l 0,08 0,20
m Angle
40° 50°
n — —

NOTE 1 Mechanical and electrical reference plane.
NOTE 2 The diameter is chosen to meet the nominal impedance of 50 Ω and electrical and
mechanical requirements.
NOTE 3 Spherical or chamfered.
Note 2 ∅n
∅d
∅b
∅a

---------------------- Page: 14 ----------------------

SIST EN 61169-44:2013
61169-44 © IEC:2012(E) – 9 –
3.1.1.3 Connector with pin-centre contact – Catchers mit

Note 1
k
m
Note 3
i
IEC  2432/12

Figure 3 – Connector with pin- centre contact – Catchers mit
(for dimensions and notes, see Table 3)

Table 3 – Dimensions of connector with pin-centre contact – Catchers mit
Ref. mm Notes
Min. Max.
a 5,84 —
b 5,38 5,54
c 3,15 3,20
d 0,38 0,41
i 2,74 2,84 —
k 1,14 1,40
m 45° ± 2° Angle
n — —
NOTE 1 Mechanical and electrical reference plane.
NOTE 2 The diameter is chosen to meet the nominal impedance of 50 Ω and electrical and
mechanical requirements.
NOTE 3 Spherical or chamfered.
Note 2
∅n
∅d
∅c
∅b
∅a

---------------------- Page: 15 ----------------------

SIST EN 61169-44:2013
– 10 – 61169-44 © IEC:2012(E)
3.1.2 Connector with socket-centre contact
Note 1

g
Note 6
f
Note 7
Note 3
c Note 8
Note 5
d
e
IEC  2433/12

Figure 4 – Connector with socket-centre contact
(for dimensions and notes, see Table 4)

Table 4 – Dimensions of connector with socket-centre contact
Ref. mm Notes
Min. Max.
a — 3,43
b — —
c 0,00 —
d 0,00 0,20
e 1,78 —
f 0,46 0,64 Uncabled
0,64 0,89 Cabled
g 2,84 —
h — —
NOTE 1 Mechanical and electrical reference plane.
NOTE 2 Bore diameter and closure to meet electrical and mechanical requirements.
NOTE 3 The form and dimensions of outer conductor to meet mechanical and electrical requirements.
NOTE 4 Diameter is chosen upon the assumption that the PTFE dielectric has a dielectric constant of
2,02 to give an impedance of 50 Ω.
NOTE 5 The number and dimension of slots allows to meet mechanical and electrical requirements.
NOTE 6 Anti-rock ring is required for cabled connectors, optional for all others.
NOTE 7 EMI ring (shield) is required for cabled connectors, optional for all others.
NOTE 8 To meet electrical requirement.
Note 4 ∅h
∅b
Note 2
∅a

---------------------- Page: 16 ----------------------

SIST EN 61169-44:2013
61169-44 © IEC:2012(E) – 11 –

3.2 Gauges
3.2.1 Gauge pin for socket-centre contact

50° ± 10°
∅0,2 mm max.
R0,4 mm max.
Bend radius
∅a
IEC  2434/12

Figure 5 – Gauge pin for socket-centre contact
(for dimensions and notes, see Table 5)

Table 5 – Dimensions of gauge pin for socket-centre contact
Ref. Gauge A Gauge B
(for sizing purposes) (for measurement of retention force for inner
conductor)
Mass of gauge: (14+2) g
mm mm
Min. Max. Min. Max.
a 0,410 0,415 0,375 0,380
b 1,00 1,14 1,00 1,14
Material: steel, polished.
Surface roughness: Ra≤0,4 µm, on the cylindrical surface of length b.

3.2.1.1 Test procedure
The gauge A shall be inserted into the socket-centre contact three times with a minimum
depth of 1,00 mm. This is a sizing operation and should only be carried out when the socket-
centre contact is removed from the connector.
After this, the gauge B shall be inserted into socket-centre contact. The contact shall retain
the mass of the gauge in a vertical downward position. The test should also be carried out on
connector when the socket-centre contact is not removed.
3.2.1.2 Additional test
At the conclusion of the tests and if prescribed in the DS, the force necessary to insert gauge
A shall be measured. When the additional test is required, the force required shall not exceed
6,67 N.
b

---------------------- Page: 17 ----------------------

SIST EN 61169-44:2013
– 12 – 61169-44 © IEC:2012(E)
3.2.2 Gauge for outer contact of connector with socket-centre contact
3.2.2.1 Gauge with limited detent for outer contact of connector with socket-centre
contact

l
m
e
g
f d
h
IEC  2435/12

Figure 6 – Gauge with limited detent for outer contact of connector
with socket-outer contact
(for dimensions and notes, see Table 6)

Table 6 – Gauge with limited detent for outer contact of connector
with socket-outer contact
Ref Gauge A Gauge B Notes
(for sizing purposes) (for measurement of retention force
for inner conductor)
Mass of gauge: (900+20) g
mm mm
Min. Max. Min. Max.
a 3,53 3,68 3,53 3,68
b 3,13 3,23 3,13 3,23
c 3,00 3,02 3,08 3,10 Note 1
d 0,84 0,94 0,84 0,94
e Note 2
28° 32° 28° 32°
f 0,52 0,60 0,52 0,60
g Note 3
33° 37° 33° 37°
h 2,74 2,84 2,74 2,84
i — 2,40 — 2,40
l 0,08 0,20 0,08 0,20
m
40° 50° 40° 50°
Material: steel, polished.
NOTE 1 Surface roughness: Ra≤0,4 µm, on the cylindrical surface of length c.
NOTE 2 Surface roughness: Ra≤0,4 µm, on the slope surface of angle e.
NOTE 3 Surface roughness: Ra≤0,4 µm, on the slope surface of angle g.
∅i
∅c
∅b
∅a

---------------------- Page: 18 ----------------------

SIST EN 61169-44:2013
61169-44 © IEC:2012(E) – 13 –
3.2.2.1.1 Test procedure
The outer contact shall be inserted into the gauge A once. This is a sizing operation.
After this, the outer contact shall be inserted into the gauge B. The outer contact shall retain
the gauge in a vertical downward direction.
3.2.2.1.2 Additional test
After the sizing and if prescribed in the DS, the force required to insert gauge A shall be
measured. This force shall not exceed 45 N.
3.2.2.2 Gauge pin – Full detent for outer contact of connector with socket-centre

l
m
e
g
f d
h
IEC  2436/12

Figure 7 – Gauge pin – Full detent for outer contact of connector with socket-centre
(for dimensions and notes, see Table 7)

∅i
∅c
∅b
∅a

---------------------- Page: 19 ----------------------

SIST EN 61169-44:2013
– 14 – 61169-44 © IEC:2012(E)
Table 7 – Gauge pin – Full detent for outer contact
of connector with socket-centre
Ref Gauge A Gauge B Notes
(for sizing purposes) (for measurement of retention force
for inner conductor)
Mass of gauge: (2 200+20) g
mm mm
Min. Max. Min. Max.

a 3,53 3,68 3,53 3,68
b 3,13 3,23 3,13 3,23
c 2,90 2,92 2,98 3,00 Note 1
d 0,84 0,94 0,84 0,94
e 28° 32° 28° 32° Note 2
f 0,52 0,60 0,52 0,60
g Note 3
33° 37° 33° 37°
h 2,74 2,84 2,74 2,84
i — 2,40 — 2,40
l 0,08 0,20 0,08 0,20
m
40° 50° 40° 50°
Material: steel, polished,
NOTE 1 Surface roughness: Ra≤0,4 µm, on the cylindrical surface of length c.
NOTE 2 Surface roughness: Ra≤0,4 µm, on the slope surface of angle e.
NOTE 3 Surface roughness: Ra≤0,4 µm, on the slope surface of angle g.

3.2.2.2.1 Test procedure
The outer contact shall be inserted into the gauge A once. This is a sizing operation.
After this, the outer contact shall be inserted into the gauge B. The outer contact shall retain
the gauge in a vertical downward direction.
3.2.2.2.2 Additional test
After the sizing and if prescribed in the DS, the force required to insert gauge A shall be
measured. This force shall not exceed 68 N.

---------------------- Page: 20 ----------------------

SIST EN 61169-44:2013
61169-44 © IEC:2012(E) – 15 –
3.2.2.3 Gauge pin – Smooth bore for outer contact of connector with socket-centre
l

m
g
c
e
IEC  2437/12

Figure 8 – Gauge pin – Smooth bore for outer contact
of connector with socket-centre
(for dimensions and notes, see Table 8)
Table 8 – Gauge pin – Smooth bore for outer contact of connector with socket-centre
Ref Gauge A Gauge B Notes
(for sizing purposes) (for meas
...

Questions, Comments and Discussion