oSIST prEN IEC 61300-2-29:2026
(Main)Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-29: Tests - Low air pressure
- Status
- Not Published
- Public Enquiry End Date
- 17-Sep-2026
- Technical Committee
- MOC - Mobile Communications
- Current Stage
- 4020 - Public enquire (PE) (Adopted Project)
- Start Date
- 30-Jun-2026
- Due Date
- 17-Nov-2026
- Completion Date
- 07-Sep-2026
oSIST prEN IEC 61300-2-29:2026 is a draft IEC/CENELEC standard in the IEC 61300 series for fibre optic interconnecting devices and passive components. It specifies a test method for determining the effect of low air pressure on a fibre optic device, and it is intended to be used together with IEC 61753 performance standards. The document covers the test chamber, optical measurements, test sequence, severity settings, and what has to be recorded in the test report.
What does oSIST prEN IEC 61300-2-29:2026 specify?
oSIST prEN IEC 61300-2-29:2026 specifies how to test a device under reduced air pressure and then return it to normal atmospheric conditions. In practice, this is the method used when a product may be exposed to altitude-related conditions and its optical performance needs to be checked before, during, and after that exposure.
The document is organized into clauses 1 to 8, plus a bibliography and Table 1. Clause 1 gives the scope, clauses 2 and 3 point to the required references and terms, clauses 4 to 7 describe the test principle, apparatus, procedure, and severity, and clause 8 lists the details that must be specified and reported.
What are the key requirements of oSIST prEN IEC 61300-2-29:2026?
Test principle and test object
oSIST prEN IEC 61300-2-29:2026 uses a device under test (DUT) that is placed in a chamber, exposed to a specified low air pressure, and then brought back to normal pressure. That sequence matters because the document is looking for changes caused by pressure reduction, not just a static visual check.
Clause 4 describes the overall flow: introduce the DUT into the chamber, reduce the air pressure to the specified value, maintain it for the required time, and then restore normal pressure.
Apparatus and measurements
oSIST prEN IEC 61300-2-29:2026 requires a test chamber that can hold the pressure condition given in clause 7. The optical measurement equipment must follow IEC 61300-3-4 for attenuation and IEC 61300-3-6 for return loss, and IEC 61300-3-3 is used when intermediate monitoring is required.
This means the test is not only environmental - it also checks whether optical performance changes during exposure.
Preparation, preconditioning, and initial checks
oSIST prEN IEC 61300-2-29:2026 requires the DUT to be prepared according to IEC 61300-1 and mated with suitable test cables. Before the first measurements, the DUT is held for 2 h under standard atmospheric conditions.
Clause 6 also requires initial visual examination and initial optical measurements as specified by the relevant IEC 61753 performance standards, with measurement wavelengths taken from those performance standards.
Low air pressure exposure and recovery
oSIST prEN IEC 61300-2-29:2026 specifies that the chamber pressure is reduced to the value set by the relevant IEC 61753 performance standard, with a pressure-change rate of not more than 15 kPa/min. The pressure is then held for the specified duration, and after the exposure it is restored to normal pressure at the same maximum change rate.
After the test, the DUT stays under standard atmospheric conditions for between 1 h and 2 h before final measurements. This recovery period matters because some effects only appear after the device has stabilized again.
Severity and acceptance-related information
oSIST prEN IEC 61300-2-29:2026 leaves the test air pressure and exposure duration to the relevant IEC 61753 performance standard, while Table 1 gives preferred air pressure and altitude pairings. The pressure tolerance is normally ±5% or ±0.1 kPa, whichever is larger, with a specific tolerance for 84 kPa.
Clause 8 requires the report to identify the DUT, the preconditioning, the initial, intermediate, recovery, and final measurements, the chosen severity, any deviations, and any additional pass/fail criteria.
What terms does oSIST prEN IEC 61300-2-29:2026 define?
- Device under test (DUT) - the fibre optic device being exposed to low air pressure and measured before and after the test.
- Standard atmospheric conditions - the ambient conditions used for preconditioning, recovery, and the reference measurements.
- Attenuation - the loss measured in the optical path, used here to check whether pressure changes affect signal transmission.
- Return loss - the reflected optical power relative to the launched power, used to assess reflective behavior under test.
- Intermediate measurements - measurements made during the low-pressure exposure when the relevant IEC 61753 performance standard requires monitoring.
- Preconditioning - the 2 h period in the chamber before the initial measurement, used to stabilize the DUT.
Who uses oSIST prEN IEC 61300-2-29:2026?
oSIST prEN IEC 61300-2-29:2026 is used by manufacturers, test laboratories, and specifiers of fibre optic interconnecting devices and passive components. It is especially relevant to teams that qualify products against IEC 61753 performance standards, compare design variants, or document environmental performance for optical connectors and related devices.
What changed in oSIST prEN IEC 61300-2-29:2026 from the previous edition?
oSIST prEN IEC 61300-2-29:2026 cancels and replaces the first edition published in 1995. The stated technical changes are a revised document structure, added terms and definitions, updated apparatus that adds optical measurement equipment, more detailed procedures, and a reconsidered severity section for air pressure.
Which standards are used with oSIST prEN IEC 61300-2-29:2026?
- IEC 61300-1 - provides general guidance, preparation rules, and the terms and definitions used in this part.
- IEC 61300-3-1 - defines visual examination, used for the initial and final inspection of the DUT.
- IEC 61300-3-3 - defines active monitoring of changes in attenuation and return loss, used for intermediate measurements.
- IEC 61300-3-4 - defines attenuation measurement.
- IEC 61300-3-6 - defines return loss measurement.
- IEC 61753 (all parts) - provides the performance standards that set the required wavelength(s), severity, and final acceptance limits.
What does the oSIST prEN IEC 61300-2-29:2026 document contain?
oSIST prEN IEC 61300-2-29:2026 contains a foreword, clauses 1 to 8, one table, and a bibliography. The core technical content is the test apparatus, the step-by-step procedure, and the severity settings for low air pressure testing.
It also lays out the measurement sequence: preparation, preconditioning, initial visual and optical checks, pressure exposure, optional intermediate monitoring, recovery, and final examination. That makes it useful for test planning, product qualification, and report preparation.
Table 1 links preferred air pressure values to approximate altitude above sea level, so users can select a severity level that matches their intended service condition. The reporting clause then turns the test into a documented record that can be compared across products or test laboratories.
Relations
- Effective Date
- 21-Oct-2025
Get Certified
Connect with accredited certification bodies for this standard

ANCE
Mexican certification and testing association.

Intertek Slovenia
Intertek testing, inspection, and certification services in Slovenia.
LNE (Laboratoire National de Métrologie et d'Essais)
French national laboratory for metrology and testing.
Sponsored listings
Frequently Asked Questions
oSIST prEN IEC 61300-2-29:2026 is a draft published by the Slovenian Institute for Standardization (SIST). Its full title is "Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-29: Tests - Low air pressure". This standard covers: Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-29: Tests - Low air pressure
Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-29: Tests - Low air pressure
oSIST prEN IEC 61300-2-29:2026 is classified under the following ICS (International Classification for Standards) categories: 33.180.20 - Fibre optic interconnecting devices. The ICS classification helps identify the subject area and facilitates finding related standards.
oSIST prEN IEC 61300-2-29:2026 has the following relationships with other standards: It is inter standard links to SIST EN 61300-2-29:1999. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
oSIST prEN IEC 61300-2-29:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-september-2026
Optični spojni elementi in pasivne komponente - Osnovni preskusni in merilni
postopki - 2-29. del: Preskusi - Nizek zračni tlak
Fibre optic interconnecting devices and passive components - Basic test and
measurement procedures - Part 2-29: Tests - Low air pressure
Lichtwellenleiter - Verbindungselemente und passive Bauteile - Grundlegende Prüf- und
Meßverfahren - Teil 2-29: Prüfungen: Niedriger Luftdruck
Dispositifs d'interconnexion et composants passifs à fibres optiques - Méthodes
fondamentales d'essais et de mesures - Partie 2-29: Essais - Basse pression
atmosphérique
Ta slovenski standard je istoveten z: prEN IEC 61300-2-29:2026
ICS:
33.180.20 Povezovalne naprave za Fibre optic interconnecting
optična vlakna devices
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
86B/5235/CDV
COMMITTEE DRAFT FOR VOTE (CDV)
PROJECT NUMBER:
IEC 61300-2-29 ED2
DATE OF CIRCULATION: CLOSING DATE FOR VOTING:
2026-06-26 2026-09-18
SUPERSEDES DOCUMENTS:
86B/5148/CD, 86B/5182A/CC
IEC SC 86B : FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS
SECRETARIAT: SECRETARY:
Japan Mr Ryo Koyama
OF INTEREST TO THE FOLLOWING COMMITTEES: HORIZONTAL FUNCTION(S):
ASPECTS CONCERNED:
SUBMITTED FOR CENELEC PARALLEL VOTING NOT SUBMITTED FOR CENELEC PARALLEL VOTING
Attention IEC-CENELEC parallel voting
The attention of IEC National Committees, members of
CENELEC, is drawn to the fact that this Committee Draft for
Vote (CDV) is submitted for parallel voting.
The CENELEC members are invited to vote through the
CENELEC online voting system.
This document is still under study and subject to change. It should not be used for reference purposes.
Recipients of this document are invited to submit, with their comments, notification of any relevant patent rights of which
they are aware and to provide supporting documentation.
Recipients of this document are invited to submit, with their comments, notification of any relevant “In Some Countries”
clauses to be included should this proposal proceed. Recipients are reminded that the CDV stage is the final stage for
submitting ISC clauses. (SEE AC/22/2007 OR NEW GUIDANCE DOC).
TITLE:
Fibre optic interconnecting devices and passive components - Basic test and measurement
procedures - Part 2-29: Tests - Low air pressure
PROPOSED STABILITY DATE: 2033
NOTE FROM TC/SC OFFICERS:
this electronic file, to make a copy and to print out the content for the sole purpose of preparing National Committee
positions. You may not copy or "mirror" the file or printed version of the document, or any part of it, for any other purpose
without permission in writing from IEC.
IEC CDV 61300-2-29 © IEC 2026
Link to Committee Draft for Vote (CDV) online document:
Click here
How to access
This link leads you to the Online Standards Development (OSD) platform for National Mirror
Committee’s (NMC) comments. The project draft may be found further down this document.
Resource materials
We recommend NCs to review the available materials to better understand the member commenting
on the OSD platform. This includes the:
• OSD NC roles overview
• How to add and submit comments to the IEC
Contact
Should you require any assistance, please contact the IEC IT Helpdesk.
IEC CDV 61300-2-29 © IEC 2026
CONTENTS
FOREWORD . 4
1 Scope . 6
2 Normative references . 6
3 Terms and definitions . 6
4 General description . 6
5 Apparatus . 6
5.1 Test chamber . 6
5.2 Optical measurement equipment . 7
6 Procedure . 7
6.1 Preparation of DUT . 7
6.2 Preconditioning . 7
6.3 Initial examination and measurements . 7
6.4 Low air pressure test and intermediate measurements . 7
6.5 Recovery . 7
6.6 Final examination and measurements . 7
7 Severity . 8
7.1 Air pressure . 8
7.2 Duration of exposure . 8
8 Details to be specified and reported . 8
Bibliography . 10
Table 1 – Air pressure and altitude . 8
IEC CDV 61300-2-29 © IEC 2026
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
Fibre optic interconnecting devices and passive components - Basic test
and measurement procedures -
Part 2-29: Tests - Low air pressure
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for
standardization comprising all national electrotechnical committees (IEC National Committees).
The object of IEC is to promote international co-operation on all questions concerning
standardization in the electrical and electronic fields. To this end and in addition to other
activities, IEC publishes International Standards, Technical Specifications, Technical Reports,
Publicly Available Specifications (PAS) and Guides (hereafter referred to as "IEC
Publication(s)"). Their preparation is entrusted to technical committees; any IEC National
Committee interested in the subject dealt with may participate in this preparatory work.
International, governmental and non-governmental organizations liaising with the IEC also
participate in this preparation. IEC collaborates closely with the International Organization for
Standardization (ISO) in accordance with conditions determined by agreement between the two
organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as
possible, an international consensus of opinion on the relevant subjects since each technical
committee has representation from all interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted
by IEC National Committees in that sense. While all reasonable efforts are made to ensure that
the technical content of IEC Publications is accurate, IEC cannot be held responsible for the
way in which they are used or for any misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC
Publications transparently to the maximum extent possible in their national and regional
publications. Any divergence between any IEC Publication and the corres ponding national or
regional publication shall be clearly indicated in the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies
provide conformity assessment services and, in some areas, access to IEC marks of conformity.
IEC is not responsible for any services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including
individual experts and members of its technical committees and IEC National Committees for
any personal injury, property damage or other damage of any nature whatsoever, whether direct
or indirect, or for costs (including legal fees) and expenses arising out of the publication, use
of, or reliance upon, this IEC Publication or any other IEC Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced
publications is indispensable for the correct application of this publication.
9) IEC draws attention to the possibility that the implementation of this document may involve
the use of (a) patent(s). IEC takes no position concerning the evidence, validity or applicability
of any claimed patent rights in respect thereof. As of the date of publication of this document,
IEC [had/had not] received notice of (a) patent(s), which may be required to impl
...