SIST EN 61076-4-103:2002
(Main)Connectors for use in d.c. low-frequency analogue and digital high speed data applications -- Part 4-103: Printed board connectors with assessed quality - Detail specification for two-part connectors with shielding and a basic grid of 2,5 mm
- Abstract
This publication also bears the number QC 480301XX0004 which is the specification number in the IEC Quality Assessment System for Electronic Components (IECQ).
- Status
- Published
- Publication Date
- 31-Aug-2002
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 01-Sep-2002
- Due Date
- 01-Sep-2002
- Completion Date
- 01-Sep-2002
SIST EN 61076-4-103:2002 is the Slovenian adoption of IEC/EN 61076-4-103 for connectors with assessed quality, for d.c., low-frequency analogue, and digital high-speed data applications. It specifies a detail specification for two-part printed board connectors with shielding and a basic grid of 2.5 mm, and it is intended for connector designers, equipment makers, cable assemblers, and quality teams working with IECQ-assessed components.
This publication also bears the IECQ specification number QC 480301XX0004. In practice, it is the document you use when you need the connector family, its mechanical interface, its electrical and EMC characteristics, and its quality assessment route in one place.
What does SIST EN 61076-4-103:2002 specify?
SIST EN 61076-4-103:2002 covers shielded printed board connectors in the IEC 61076 family, with two-part mating, a 2.5 mm basic grid, and assessed quality for use in d.c., low-frequency analogue, and digital high-speed data applications. The document gives the connector styles, mounting options, dimensions, electrical and mechanical characteristics, test schedule, and quality assessment procedures.
The structure is practical:
- Clause 1 gives general data, ratings, marking, type designation, and ordering information.
- Clause 2 defines the connector terms, styles, variants, application information, and contact arrangements.
- Clause 3 gives dimensional information, mating details, accessories, mounting information, and gauges.
- Clause 4 sets the electrical, mechanical, and EMC characteristics.
- Clause 5 sets the test schedule and test arrangements.
- Clause 6 gives the quality assessment procedures for qualification approval, conformance inspection, and delayed delivery re-inspection.
What are the key requirements of SIST EN 61076-4-103:2002?
The standard is built around a shielded cable-to-board connector system with defined mounting, coding, and test behavior. For a designer or buyer, the main point is that the document combines interface dimensions with performance limits, so you can check fit, function, and acceptance testing against one specification.
Mounting and application concepts
Clause 1.1 describes how the free cable connector is mounted on a round cable, with the cable shield connected to the conductive shell and the cable insulation held by a strain relief device. Signal wires may terminate by crimp, insulation displacement connection (IDC), or through an internal printed board with a transition device. This matters because the cable build-up and shield termination are part of the qualified interface, not just the contacts.
The standard recommends three applications: rear plug-up connection, connection to backplane, and connection through front panel. Clause 1.1 also explains how the fixed board connector is attached in each case, which is important when choosing a style for a backplane or panel layout.
Ratings and environmental performance
Clause 1.2 states the key ratings and characteristics. The connector family is rated for 500 V r.m.s. contact to contact, 1 A at 70 °C, and a minimum insulation resistance of 5 GΩ. It also assigns climatic categories for performance levels PL 1 and PL 2, and gives initial shielding effectiveness and ESD performance values.
For users, this means the connector can be selected against the electrical stress and environment of the equipment, and the product data can be checked against the specified performance level. Clause 4 expands these ratings into testable limits.
Style, variant, and designation control
Clause 2.2 and clause 1.5 define the style system, termination variants, cable diameters, and IEC type designation. The designation encodes the connector style, number of contact cavities, cable diameter, contact type, termination type, loaded rows, loaded contact pattern, contact level pattern, performance level, and assessment level. In practice, this is the ordering language for procurement and traceability.
Clause 2.4 defines how contact arrangements are selected, including which rows are loaded, which loading pattern is used, and, for fixed board connectors, which contact levels are applied. This matters because the mating sequence and circuit loading are part of the part number, not just drawing notes.
Mechanical fit, polarization, and coding
Clause 2.3 defines polarization, locking, coding devices, default code, and shielding behavior. The standard uses location pegs, locking latches, and coding keys to prevent wrong assembly and to block incompatible mating before electrical contact is made. For the user, this reduces assembly errors and supports keyed versions of the same family.
The document also defines a contact range, engagement sequence, and first possible contact point. Clause 3 then gives the dimensional limits for misalignment and inclination during insertion. These controls matter in backplane and panel assemblies because they determine how forgiving the connector is during assembly and service.
Electrical, mechanical, and EMC limits
Clause 4 sets the acceptance limits. Electrical checks include creepage and clearance distances, voltage proof, current-carrying capacity, contact resistance, and insulation resistance. Mechanical checks include operation count, engaging and separating forces, contact retention, static load, vibration, shock, insert retention, cable-clamp resistance to rotation, and coupling-device effectiveness.
The EMC part requires shielding effectiveness and electrostatic discharge performance. For practice, this means the connector is not only a pin-and-shell design but a complete shielded interconnect system, with measured shield continuity and disturbance limits.
Quality assessment and inspection
Clause 6 gives the quality assessment route. It covers qualification approval testing, lot-by-lot quality conformance inspection, periodic tests, and re-inspection for delayed delivery. The standard also uses assessment levels, acceptable quality levels (AQL), and certified test records (CTR). That is important when the connector is bought as an assessed-quality component and the customer needs traceable acceptance evidence.
What terms does SIST EN 61076-4-103:2002 define?
- System unit (SU) - the modular pitch of 25 mm that underpins the connector’s mechanical layout.
- Contact range - the distance range between fixed and free connector reference planes within which the specified contact resistance is maintained.
- Contact level - a group of contacts that engage or separate at the same time.
- Engaging sequence - the defined order in which contact levels mate or separate.
- Coding devices - accessories that make only selected connector pairs mateable and block incompatible pairs.
- Default code - a pre-set coding configuration that makes the fixed and free parts a matching pair.
- Rear plug-up contact - a termination post that presses into the backplane and projects rearward as a male contact.
- Locking device - the feature that holds the free cable connector in the mated state and resists the specified static load.
Who uses SIST EN 61076-4-103:2002?
Connector designers use this standard to define the mechanical envelope, contact arrangement, coding, and shielding interface. Equipment manufacturers use it when designing backplanes, front panels, and cable assemblies around the 25 mm equipment practice.
Quality managers and test laboratories use it for qualification approval, conformance inspection, and periodic testing. Buyers and sourcing teams use it to compare part numbers, performance levels, and assessment levels when selecting assessed-quality components.
It is relevant to electronic equipment, interconnect, and cable-assembly work where shielded board connectors must support controlled mating, EMC performance, and documented quality assessment.
Which standards are used with SIST EN 61076-4-103:2002?
- IEC 60068-1 - gives the general environmental testing conditions used unless otherwise stated.
- IEC 60352-5 - provides the general requirements and test methods for solderless press-in connections.
- IEC 60410 - gives the sampling plans and attribute inspection procedure used in quality inspection.
- IEC 60512 series - supplies the basic electrical, mechanical, dynamic stress, endurance, and miscellaneous connector test methods used throughout the standard.
- IEC 60512-23-3 - covers shielding effectiveness testing for connectors with cables affixed.
- IEC 60917 and IEC 60917-2-2 - provide the 25 mm equipment practice and coordination dimensions used as the reference system.
- IEC 61000-4-2 - provides the electrostatic discharge immunity test method.
- IEC 61076-1 - provides the generic specification and the approval framework for this family.
- IEC 61076-4 - provides the sectional specification for printed board connectors, including marking and type designation rules.
- IEC 61076-4-100 - gives the related detail specification for two-part connectors with a basic grid of 2.5 mm for printed boards and backplanes.
- ISO 468 - provides the surface roughness rules used for the gauges.
What does the SIST EN 61076-4-103:2002 document contain?
The document contains style surveys, dimensional drawings, contact arrangement diagrams, and examples of type designation. It also contains test fixtures and gauge drawings for sizing, retention force, first contact point, and static load.
Clause 5 includes detailed test schedule tables for preliminary, dynamic/climatic, mechanical endurance, moisture, electrical load, mechanical resistivity, chemical resistivity, and connection-related testing. These tables are used for qualification, routine inspection, and periodic verification.
The figures show recommended applications, connector style families, misalignment and inclination limits, shielding arrangements, and ESD and shielding test set-ups. The tables also support ordering and production control by linking part designation to contact loading, termination type, cable diameter, and performance level.
Relations
- Effective Date
- 10-Feb-2026
- Effective Date
- 09-Feb-2026
- Effective Date
- 09-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
- Effective Date
- 03-Feb-2026
Frequently Asked Questions
SIST EN 61076-4-103:2002 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Connectors for use in d.c. low-frequency analogue and digital high speed data applications -- Part 4-103: Printed board connectors with assessed quality - Detail specification for two-part connectors with shielding and a basic grid of 2,5 mm". This standard covers: This publication also bears the number QC 480301XX0004 which is the specification number in the IEC Quality Assessment System for Electronic Components (IECQ).
This publication also bears the number QC 480301XX0004 which is the specification number in the IEC Quality Assessment System for Electronic Components (IECQ).
SIST EN 61076-4-103:2002 is classified under the following ICS (International Classification for Standards) categories: 31.220.10 - Plug-and-socket devices. Connectors. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 61076-4-103:2002 has the following relationships with other standards: It is inter standard links to SIST ISO 468:1995, SIST EN 663:1999, SIST EN ISO 14272:2002, SIST EN 60512-23-3:2002, SIST EN 61076-4:2002, SIST EN 61076-1:2002, SIST EN 60917-2-2:2002, SIST EN 61000-4-2:1997, SIST EN 60068-1:2001. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
SIST EN 61076-4-103:2002 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- FOREWORD
- 1 General data
- 1.1 Recommended method of mounting
- 1.2 Ratings and characteristics
- 1.3 Normative references
- 1.4 Marking
- 1.5 IEC type designation
- 0 Not applicable
- 1 Unplated
- 2 Silver alloy
- 0 Not applicable
- 1 Gold alloy
- 2 Palladium alloy with gold flash
- 00 Blind / not applicable
- 1.6 Ordering information
- 2 Technical data
- 2.1 Definitions
- 2.2 Survey of styles and variants
- 2.3 Information on application
- 2.4 Survey of contact arrangements
- 2 Rows b + d
- 5 Rows a + b + c + d + e
- 3 All even numbered contacts
- 5 Chess pattern even numbered in row a
- 3 Dimensional information
- 3.1 General
- 3.2 Isometric view and common features
- 3.3 Mating information
- 3.4 Fixed board connectors
- 3.5 Free cable connectors
- 3.6 Accessories
- 3.7 Mounting information for fixed board connectors
- 3.8 Gauges
- 4 Characteristics
- 4.1 Climatic category
- 4.2 Electrical characteristics
- 4.3 Mechanical characteristics
- 1 SU 200 N 100 N
- 2 SU and 4 SU 300 N 150 N
- 4.4 Electromagnetic compatibility (EMC)
- 5 Test schedule
- 5.1 General
- 5.2 Test schedule tables
- 5 N min. normal operation
- 6 Quality assessment procedures
- 6.1 Qualification approval testing
- 6.2 Quality conformance inspection
- 6.3 Delayed delivery, re-inspection
FOREWORD
1) The IEC (International Electrotechnical Commission) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees). The object of the IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, the IEC publishes International Standards. Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work. International, governmental and non-governmental organizations liaising with the IEC also participate in this preparation. The IEC collaborates closely with the International Organization for Standardization (ISO) in accordance with conditions determined by agreement between the two organizations.
2) The formal decisions or agreements of the IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all interested National Committees.
3) The documents produced have the form of recommendations for international use and are published in the form of standards, technical reports or guides and they are accepted by the National Committees in that sense. 4) In order to promote international unification, IEC National Committees undertake to apply IEC International Standards transparently to the maximum extent possible in their national and regional standards. Any divergence between the IEC Standard and the corresponding national or regional standard shall be clearly indicated in the latter.
5) The IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any equipment declared to be in conformity with one of its standards. 6) Attention is drawn to the possibility that some of the elements of this International Standard may be the subject of patent rights. The IEC shall not be held responsible for identifying any or all such patent rights. International Standard IEC 61076-4-103 has been prepared by subcommittee 48B: Connectors, of IEC technical committee 48: Electromechanical components and mechanical structures for electronic equipment.
The text of this standard is based on the following documents:
FDIS Report on voting 48B/737/FDIS 48B/750/RVD Full information on the voting for the approval of this standard can be found in the report on voting indicated in the above table.
Future standards in the series will carry the new general title as cited above. Titles of existing standards in this series will be updated when a new edition is prepared. The QC number that appears on the front cover of this publication is the specification number in the IEC Quality Assessment System for Electronic Components (IECQ).
SIST EN 61076-4-103:2002
CONNECTORS FOR USE IN DC LOW-FREQUENCY ANALOGUE AND DIGITAL HIGH SPEED DATA APPLICATIONS – Part 4-103: Printed board connectors with assessed quality – Detail specification for two-part connectors with shielding and a basic grid of 2,5 mm International Electrotechnical Commission IEC 61076-4-103 QC 480301XX0004 IEC SC 48B – Connectors Electronic components of assessed quality in accordance with: Blank detail specification:
GENERIC SPECIFICATION IEC 61076-1, Issue 1, 1995 IEC 61076-4-001, Issue 1, 1996 Cable-to-board connectors, shielded, for printed boards and backplanes, grid of 2,5 mm, in accordance with IEC 60917.
Modular, five-row connector, with high performance shielding, locking and coding features.
Fixed board connectors 25 mm to 250 mm high, free cable connectors 25 mm to 100 mm high.
Performance levels (PL): 1, 2 Assessment level: G IEC 1 882/98 Information on the availability of components qualified to this detail specification is given in the qualified products list.
SIST EN 61076-4-103:2002
1 General data
1.1 Recommended method of mounting
The free cable connector shall be connected to a round cable.
The shielding braid of the cable shall be connected to the conductive shell of the housing, and the insulation of the cable shall be retained by a strain relief device. The signal wires shall be connected either directly to the female contacts by crimped or insulation displacement connections (IDC), or to an internal printed circuit board by means of a transition device.
The cable-to-board connectors are recommended for the use in three different applications:
Application a, rear plug-up connection; Application b, connection to backplane; Application c, connection through front panel.
See figure 1 for location of the above-mentioned reference letters. Depending on the application the fixed board connectors shall be attached to the backplane or to the front panel through the press-in connections of their shielding frames. Application a: for rear plug-up connections, the empty shroud of the fixed board connector accommodates the rear plug-up terminations of the fixed connector, which is mounted on the frontside of the backplane (for example a fixed board connector according to IEC 61076-4-100).
Application b: for backplane connections, the fixed board connector shall be equipped with male contacts, which are pressed into the backplane, together with the press-in terminations of its shielding frames.
Application c: for front panel connections, the fixed board connector shall be equipped with male contacts and rear plug-up terminations, which connect to a free connector on the printed board (for example a free board connector according to IEC 61076-4-100).
1.1.1 Number of contacts and contact cavities
Table 1 – Number of contacts and contact cavities for free cable connectors Styles Shape of Connection ½ SU 1 SU 2 SU 4 SU (see 2.2.1) housing A Straight, short IDC or crimp 20 45 90 180 B Straight, long Angled press-in – 35 70 140 IDC or crimp – 45 90 180 C 35° angled IDC or crimp – 45 90 180
SIST EN 61076-4-103:2002
Table 2 – Number of contacts and contact cavities for fixed board connectors Styles (see 2.2.1) 1 SU 2 SU 4 SU 6 SU 8 SU 9 SU 10 SU P and Q 45 90 180 270 360 405 450 R and T 40 80 160 240 320 360 400
1.2 Ratings and characteristics
Rated voltage: contact/contact 500 V r.m.s.
Current rating: 1 A at 70 °C (all signal contacts loaded) Insulation resistance: 5 GΩ min.
Climatic category: PL 1: 40/100/56 PL 2: 40/100/21 Shielding effectiveness: initial 70 dB min. average value Electrostatic discharge: induced voltage 250 mV maximum by 8 kV contact discharge Printed board: plated-through hole diameter 0,94 mm to 1,09 mm Backplane thickness:
- for rear plug-up applications 3,0 mm to 5,0 mm
- other than rear plug-up applications 1,4 mm to 5,6 mm
SIST EN 61076-4-103:2002
Figure 1a - Rear plug-up connection Figure 1b - Connection to backplane Figure 1c - Connection through front panel IEC 1 883/98 Figure 1 – Three recommended applications for cable-to-board connectors
SIST EN 61076-4-103:2002
1.3 Normative references
The following normative documents contain provisions which, through reference in this text, constitute provisions of this part of IEC 61076. At the time of publication, the editions indicated were valid. All normative documents are subject to revision, and parties to agreements based on this part of IEC 61076, are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below. Members of IEC and ISO maintain registers of currently valid International Standards.
IEC 60068-1:1988, Environmental testing – Part 1: General and guidance IEC 60352-5:1995, Solderless connections – Part 5: Solderless press-in connections – General requirements, test methods and practical guidance IEC 60410:1973, Sampling plans and procedures for inspection by attributes IEC 60512:—, Electromechanical components for electronic equipment – Basic testing procedures and measuring methods IEC 60512-2:1985, Electromechanical components for electronic equipment – Basic testing procedures and measuring methods – Part 2: General examination, electrical continuity and contact resistance tests, insulation tests and voltage stress tests IEC 60512-3:1976, Electromechanical components for electronic equipment – Basic testing procedures and measuring methods – Part 3: Current carrying capacity tests IEC 60512-4:1976, Electromechanical components for electronic equipment – Basic testing procedures and measuring methods – Part 4: Dynamic stress tests IEC 60512-5:1992, Electromechanical components for electronic equipment – Basic testing procedures and measuring methods – Part 5: Impact tests (free components), static load tests (fixed components), endurance tests and overload tests IEC 60512-7:1993, Electromechanical components for electronic equipment – Basic testing procedures and measuring methods – Part 7: Mechanical operating tests and sealing tests IEC 60512-8:1993, Electromechanical components for electronic equipment – Basic testing procedures and measuring methods – Part 8: Connector tests (mechanical) and mechanical tests on contacts and terminations IEC 60512-9:1992, Electromechanical components for electronic equipment – Basic testing procedures and measuring methods – Part 9: Miscellaneous tests IEC 60512-23-3:—, Electromechanical components for electronic equipment – Basic testing procedures and measuring methods – Part 23: Electromagnetic compatibility – Section 3: Test 23c:
1) Shielding effectiveness, from 10 kHz to 1 000 kHz, on connectors with cables affixed IEC 60917:1988, Modular order for the development of mechanical structures for electronic equipment practices IEC 60917-2-2:1994, Modular order for the development of mechanical structures for electronic equipment practices – Part 2: Sectional specification – Interface coordination dimensions for the 25 mm equipment practice – Section 2: Detail specification – Dimensions for subracks, chassis, backplanes, front panels and plug-in units
1) To be published.
SIST EN 61076-4-103:2002
IEC 61000-4-2:1995, Electromagnetic compatibility (EMC) – Part 4: Testing and measurement techniques – Section 2: Electrostatic discharge immunity test – Basic EMC publication IEC 61076-1:1995, Connectors with assessed quality, for use in d.c., low frequency analogue and in digital high speed data applications – Part 1: Generic specification IEC 61076-4:1995, Connectors with assessed quality, for use in d.c., low frequency analogue and in digital high speed data applications – Part 4: Sectional specification – Printed board connectors IEC 61076-4-100:1994, Connectors with assessed quality, for use in d.c., and low frequency analogue applications and in digital applications with high speed data – Part 4: Sectional specification – Printed board connectors – Section 100: Detail specification for two-part connectors having a basic grid of 2,5 mm, for printed boards and backplanes ISO 468:1982, Surface roughness – Parameters, their values and general rules for specifying requirements
1.4 Marking
The marking of the connector and the package shall be in accordance with 2.6 of IEC 61076-4.
1.5 IEC type designation
See 2.1 for definitions and 2.2 for designation of styles and variants. The designation shall be derived in accordance with 2.5 of IEC 61076-4. Example for free cable connector:
A straight 1 SU free cable connector with cable adapter for cables Ø 10 mm, fully loaded with palladium and gold-flash plated contacts in all five rows with 90° angled press-in terminations for internal printed board, meeting performance level 2 and assessment level G, is designated as follows:
IEC 61076-4-103 – B035F510 – L140202G Example for fixed connector:
A 10 SU fixed board connector, fully loaded in all five rows with signal contacts level 1 and 12 mm rear plug-up spills, palladium and gold-flash plated, and with silver alloy plated shielding contacts, meeting performance level 1 and assessment level G, is designated as follows:
IEC 61076-4-103 – Q450M511 – U100231G Example for single contacts:
A single female contact, with crimp termination, palladium and gold-flash plated, meeting performance level 2 and assessment level G, is designated as follows:
IEC 61076-4-103 – S001F000 – C100202G
SIST EN 61076-4-103:2002
IEC 61076-4-103 L N N N L N N N L N N N N N N L NOTE – L stands for letter,
N stands for digit.
Reference to this specification Assessment level Connector style G Level G (see 2.2.1) Cable connector straight Performance level short A long B 1 Performance level 1 Cable connector angled 35° C 2 Performance level 2 Plug-up shroud P Loaded shroud Q Plug-up shroud with ½ SU R Contact finish of compartments shielding contacts Single contact S
0 Not applicable
Loaded shroud with ½ SU T
1 Unplated
compartments
2 Silver alloy
Number of contact cavities Contact finish of signal contact (depending on connector style:
see 1.1.1)
0 Not applicable
1 Gold alloy
Single contact 001 – –
2 Palladium alloy with gold flash
1/2 SU 020 – – 1 SU 045 035 040 2 SU 090 070 080 Cable diameter (see 2.2.3) 4 SU 180 140 160
00 Blind / not applicable
6 SU 270 – 240 9 SU 405 – 360 XX See table in 2.2.3 10 SU 450 – 400 Type of contact Type of termination Variant (see 2.2.2) Female F Male M C1 Crimp small Coding device K C2 average I1 Insulation displacement small Loaded contact rows (see 2.4) I2 average L1 Press-in angled 3 mm Empty body 0 / not applicable P1 Press-in straight 4,5 mm a + c + e 1 P2 6 mm b + d 2 U1 Rear plug-up 12 mm a + b + c + d + e 5 Z0 Not applicable Pattern of loaded contacts Pattern of contact levels (see 2.4) (see 2.4) Empty body 0 0 Empty body / not applicable / not applicable Fully loaded 1 1 All contacts level 1 All even numbered contacts 3 2 Level 2 at corner contacts, others level 1 Chess pattern even numbered in row a 5
1.6 Ordering information
For ordering connectors according to this detail specification, the IEC type designation described in 1.5 shall be used.
SIST EN 61076-4-103:2002
2 Technical data
2.1 Definitions
For the purpose of this part the following definitions apply:
2.1.1 Mechanical features
internal printed board printed board which is mounted inside the free cable connector housing, connected to the free connector insert by means of angled press-in terminations location pegs posts, protruding from the connector housing, fitting into corresponding holes in the printed board or backplane, preventing a wrong assembly and giving an accurate position locking device device which retains the free cable connector in its mated state and withstands the specified static load locking latches elastic levers which snap under the noses of the free cable connector housing on full insertion system unit (SU) modular pitch of 25 mm, which is the basis for the design of all mechanical features
2.1.2 Contacts and terminations
contact range the minimum to maximum distance between the reference planes of the fixed and free board connectors, within which the specified contact resistance is met chess pattern contact arrangement where the loaded and the unloaded positions alternate in rows and columns, like the fields on a chess-board chess pattern, odd in a chess pattern having loaded contacts on odd positions in row a rear plug-up contact termination post, usually being pressed-in into the backplane and emerging on the rear side as a male contact, to be connected to a free board connector press-in shoulders flanges on both sides of the male contact, supporting the mechanical forces to press the contact into the backplane
2.1.3 Engagement sequence
contact level group of contacts which engage/separate simultaneously, within the limits required by a reliable engaging sequence engaging sequence distinct order in the engaging/separating process of contacts belonging to different contact levels first possible contact point depth dimension of the first point on the female contact, which can possibly be touched by the incoming male contact first reliable contact point depth dimension of the point on the female contact, from where the specified contact resistance with the incoming male contact is met
SIST EN 61076-4-103:2002
2.1.4 Mechanical coding
coding devices accessories allowing the user to make specific pairs of connectors by providing them with matching coding devices Only connector pairs equipped with matching coding devices are intermateable, pairs with interfering coding devices are blocked off during insertion, preventing all electrical contact. default code solid, pre-set coding configuration in the free-cable and fixed-board connectors, making them a matching pair, and protecting them in the future from mating with specific code settings
2.2 Survey of styles and variants
2.2.1 Styles of connectors
Free cable connectors Table 3 – Survey of free cable connector styles Style ½ SU 1 SU 2 SU 4 SU A Straight short, for crimp or IDC terminations B Straight long, for crimp or IDC terminations and for angled press-in connection of internal printed board C Angled 35° upwards, for crimp or IDC terminations
SIST EN 61076-4-103:2002
Fixed board connector shrouds IEC 1 884/98 Figure 2 – Survey of fixed board connector styles
2.2.2 Survey of termination variants
Table 4 – Termination variants Variant Length or wire gauge Basic type of termination (see 3.4.3 and 3.5.3) 2 2 C C1 Stranded wire 0,09 mm to 0,14 mm Crimp connection, according to IEC 60352-2 2 2 Stranded wire 0,22 mm to 0,35 mm C2 I I1 Solid wire: Ø 0,25 mm to 0,40 mm 2 2 7-stranded wire: 0,09 mm to 0,14 mm Insulation displacement connection according to IEC 60352-3 I2 Solid wire: Ø 0,40 mm to 0,63 mm 2 2 7-stranded wire: 0,22 mm to 0,35 mm L 3 mm L1 90° angled compliant press-in connection for plated-through hole Ø 1, according to IEC 60352-5 P P1 4,5 mm Straight compliant press-in connection for plated-through hole Ø 1, according to IEC 60352-5 P2 6 mm U Straight, with rear plug-up contact area 12 mm U1
2.2.3 Survey of cable diameters
Table 5 – Cable diameters Style of housing Designation in 1.5 Nominal cable Tolerance range of ( = Ø × 4 ) diameter cable Ø mm mm All 00 Blind – All 20 5 24 6 28 7 +0,4 32 8 –0,8 36 9 40 10 1 SU, 2 SU, 4 SU 44 11 +0,5 48 12 –1,0 52 13
SIST EN 61076-4-103:2002
2.3 Information on application
2.3.1 Complete connectors (pairs)
Description The connector family has a basic grid of 2,5 mm and a mounting pitch of 25 mm (System Unit = SU).
It consists of a fixed connector with a modular shielded shroud, where a plurality of shielded free cable connectors may be plugged-in.
The fixed connector shroud has up to 10 slots of 25 mm long.
The free connector housings may have up to four inserts of 25 mm long, they may be stacked end to end, and fit in all slots of the modular shroud.
The smallest free connector housings, with only half an insert (12,5 mm), are used in pairs, and together fit in one slot of the modular shroud.
Electrically, the shielding braid of the round cables is connected to the housing shells of the free connectors.
These shells make contact with the shielding frames on four sides in the slots of the modular shroud. The shielding frames of the modular shroud are pressed-in the backplane or the front panel of the equipment practice.
Mechanically, the round cables are clamped to the housing shells of the free connectors. These housings snap under the locking latches of the modular shroud. The locking latches are part of the shielding frames of the modular shroud, and are mechanically fixed to the backplane or the front panel by means of the press-in connections.
...