SIST EN 300 392-11-21 V1.1.1:2003
(Main)Terrestrial Trunked Radio (TETRA); Voice plus Data (V+D); Part 11: Supplementary services stage 2; Sub-part 21: Ambience Listening (AL)
- Abstract
Analysis of predicted needs for digital trunked systems in Europe; definition of services to be provided; analysis of spectrum req ments; characteristics of relevant interfaces Contains: TETRA 08.60 to 08.85
- Status
- Published
- Publication Date
- 30-Nov-2003
- Withdrawal Date
- 30-Jun-1999
- Technical Committee
- RES - Radio equipment and systems
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 01-Dec-2003
- Due Date
- 01-Dec-2003
- Completion Date
- 01-Dec-2003
Buy Documents
SIST EN 300 392-11-21 V1.1.1:2003 is the SIST version of a TETRA standard for Voice plus Data (V+D) supplementary services. It specifies the stage 2 functional model and signalling for Supplementary Service Ambience Listening (SS-AL) in Trans-European Trunked Radio (TETRA), so that a served user can invoke hidden listening of an affected user. The document is aimed at TETRA network operators, system designers, and terminal or Switching and Management Infrastructure (SwMI) implementers who need to define how the service is set up, routed, and cleared.
What does SIST EN 300 392-11-21 V1.1.1:2003 specify?
SIST EN 300 392-11-21 V1.1.1:2003 specifies the stage 2 definition of SS-AL for TETRA. Stage 2 means it identifies the functional entities involved in the service and the information flows between them.
The scope makes two practical boundaries clear: charging principles and Man-Machine Interface (MMI) are outside the document, while the service itself is defined as a special voice call teleservice in which the affected user’s Mobile Station (MS) or Line Station (LS) transmits without action from, or indication to, that user.
The document is organized around:
- Clause 1, scope
- Clause 2, normative references
- Clause 3, definitions and abbreviations
- Clause 4, the SS-AL stage 2 specification, including the functional model, information flows, sequences, functional entity actions, allocation of Functional Entities (FEs) to physical equipment, and inter-working considerations
What are the key requirements of SIST EN 300 392-11-21 V1.1.1:2003?
The main requirement of SIST EN 300 392-11-21 V1.1.1:2003 is that SS-AL shall be modelled and signalled through named functional entities and defined message flows. In practice, this gives implementers a common call-handling model for home and visited systems.
Functional model and roles
Clause 4.1 defines five FEs:
- FE1 for the served user
- FE2 for AL control in the served user’s home system
- FE3 for the affected user
- FE4 for generic control in a visited system
- FE5 for a second listening party
The named relationships between these FEs show where signalling may pass in different system topologies. This matters because roaming and inter-system routing are part of the service, not an afterthought.
Interrogation
Clause 4.2.1.1 defines INTERROGATE-REQUEST and INTERROGATE-RESULT. The served user can interrogate SS-AL for a single identity, a list, or a range of identities, and the result can confirm invocation status or return rejection, lack of authorization, unknown identity, or invalid parameters.
In practice, this is the check a user or control point uses before attempting the service, and it tells the network whether the service is available for the targeted identities.
Invocation and acknowledgement
Clause 4.2.1.2 defines the invocation flows:
- INVOKE-REQUEST1 starts an AL call and can include a second listening party address
- INVOKE-REQUEST2 adds a second listening party to an ongoing AL call
- INVOKE is sent to the affected user’s application layer
- INVOKE-ACK confirms or rejects the invocation
- INVOKE-RESULT reports success or failure to the served user
This matters because the affected user must not see the AL signalling, while the served user still needs a clear outcome from the network.
Second listening party
Clause 4.2.1.3 defines INFORMATION, which tells a second listening party that the incoming call is an AL call. The sequence clauses show that this can happen when the second listening party is in the home system or a visited system.
For users, this means the service can include an additional listener without changing the basic purpose of the call.
Call handling and cleardown
Clause 4.2.3.10 and FE actions in clause 4.2.4 show that the AL call may be cleared if a new incoming call arrives for the affected user, based on call priority. Normal call disconnection procedures from ETS 300 392-2 apply.
In practice, this means the implementation must support priority handling and release behaviour, not just call setup.
Physical allocation and inter-working
Clause 4.3 maps the FEs to SwMI, LS, and MS, which helps designers place the function in the right equipment. Clause 4.4 says SS-AL may extend across several TETRA networks and requires service activation, deactivation, interrogation, invocation, message addressing and routing, and allocation of visited subscriber identities.
That is important for roaming and inter-network deployment, where the call may cross more than one TETRA system.
What terms does SIST EN 300 392-11-21 V1.1.1:2003 define?
- AL call - A call in which ambience listening is requested, and during which the affected user’s MS or LS transmits without action from, or indication to, the affected user.
- affected user - The user who is subject to the operation of SS-AL.
- served user - The user who invokes the supplementary service.
- second listening party - A TETRA individual or group that may listen in on the AL call.
- FE (Functional Entity) - A functional block used in the service model to show where control and signalling actions occur.
- MS (Mobile Station) - The mobile TETRA terminal that may be placed into SS-AL.
- LS (Line Station) - The fixed line-connected station that may also be used in SS-AL.
- SwMI (Switching and Management Infrastructure) - The network infrastructure that controls TETRA switching and management functions.
Who uses SIST EN 300 392-11-21 V1.1.1:2003?
SIST EN 300 392-11-21 V1.1.1:2003 is used by TETRA network operators, SwMI suppliers, terminal manufacturers, and system integrators who need to implement SS-AL. It is also relevant to interoperability and conformance test teams because the document specifies the message flows, state sequences, and entity actions that need to be verified.
Buyer and quality roles use it to check whether a product or network feature supports hidden ambience listening, roaming between home and visited systems, and optional second-listener handling.
Which standards are used with SIST EN 300 392-11-21 V1.1.1:2003?
| Standard | What it contributes |
|---|---|
| CCITT Recommendation I.130 | A method for characterizing telecommunication services supported by an ISDN and network capabilities of an ISDN. |
| ETS 300 392-2 | The TETRA Air Interface, used here for basic call handling and normal disconnection procedures. |
| ETS 300 392-1 | General Network Design for TETRA, used as the broader network model behind SS-AL. |
| ITU-T Recommendation Z.100 | Specification and Description Language (SDL), used for formal service description. |
The foreword also places this document in the TETRA multi-part family, including parts on general network design, air interface, inter-working, gateways, terminal equipment interface, line connected stations, security, management services, supplementary services stages 1 to 3, the SDL model of the air interface, PICS proforma, and inter-working extended operations.
What does the SIST EN 300 392-11-21 V1.1.1:2003 document contain?
The document contains a functional model for SS-AL, tables for the contents of each information flow, and call-sequence figures for home-system and visited-system cases. It also includes action lists for FE1 to FE5, which show what each entity does when requests, acknowledgements, or releases are received.
For engineering use, the most useful parts are the message definitions, the relationship between SS-AL signalling and basic call signalling, and the inter-working scenarios across systems. For testing, the document provides the basis for checking interrogation, invocation, second-listener insertion, and cleardown behaviour.
Buy Documents
Get Certified
Connect with accredited certification bodies for this standard

ANCE
Mexican certification and testing association.

Intertek Slovenia
Intertek testing, inspection, and certification services in Slovenia.

LNE (Laboratoire National de Métrologie et d'Essais)
French national laboratory for metrology and testing.
Sponsored listings
Frequently Asked Questions
SIST EN 300 392-11-21 V1.1.1:2003 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Terrestrial Trunked Radio (TETRA); Voice plus Data (V+D); Part 11: Supplementary services stage 2; Sub-part 21: Ambience Listening (AL)". This standard covers: Analysis of predicted needs for digital trunked systems in Europe; definition of services to be provided; analysis of spectrum req ments; characteristics of relevant interfaces Contains: TETRA 08.60 to 08.85
Analysis of predicted needs for digital trunked systems in Europe; definition of services to be provided; analysis of spectrum req ments; characteristics of relevant interfaces Contains: TETRA 08.60 to 08.85
SIST EN 300 392-11-21 V1.1.1:2003 is classified under the following ICS (International Classification for Standards) categories: 33.070.10 - Terrestrial Trunked Radio (TETRA). The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 300 392-11-21 V1.1.1:2003 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- 1 Scope
- 2 References
- 3 Definitions and abbreviations
- 3.1 Definitions
- 8 ETSI EN 300 392-11-21 V1.1.1 (2003-04)
- 3.2 Abbreviations
- 4 Functional model
- 4.1 Functional model description
- 9 ETSI EN 300 392-11-21 V1.1.1 (2003-04)
- 4.2 Description of FEs
- 10 ETSI EN 300 392-11-21 V1.1.1 (2003-04)
- 5 Information flows
- 5.1 Definition of information flows
- 11 ETSI EN 300 392-11-21 V1.1.1 (2003-04)
- 12 ETSI EN 300 392-11-21 V1.1.1 (2003-04)
- 13 ETSI EN 300 392-11-21 V1.1.1 (2003-04)
- 14 ETSI EN 300 392-11-21 V1.1.1 (2003-04)
- 15 ETSI EN 300 392-11-21 V1.1.1 (2003-04)
- 5.2 Relationship of information flows to basic call information
- 5.3 Service primitives
- 5.4 Information flow sequences
- 16 ETSI EN 300 392-11-21 V1.1.1 (2003-04)
- 17 ETSI EN 300 392-11-21 V1.1.1 (2003-04)
- 18 ETSI EN 300 392-11-21 V1.1.1 (2003-04)
- 19 ETSI EN 300 392-11-21 V1.1.1 (2003-04)
- 20 ETSI EN 300 392-11-21 V1.1.1 (2003-04)
- 21 ETSI EN 300 392-11-21 V1.1.1 (2003-04)
- 22 ETSI EN 300 392-11-21 V1.1.1 (2003-04)
- 5.5 FE Actions
- 23 ETSI EN 300 392-11-21 V1.1.1 (2003-04)
- 24 ETSI EN 300 392-11-21 V1.1.1 (2003-04)
- 6 Allocation of FEs to physical equipment
- 25 ETSI EN 300 392-11-21 V1.1.1 (2003-04)
- 7 Interworking considerations
- 26 ETSI EN 300 392-11-21 V1.1.1 (2003-04)
1 Scope
The present document defines the stage 2 specification of the Supplementary Service Ambience Listening (SS-AL) for the Terrestrial Trunked Radio (TETRA). Stage 2 identifies the functional entities involved in the supplementary service and the information flows between them. Aspects relating to all supplementary services are detailed in EN 300 392-9 [2].
NOTE: The stage 2 description is followed by the stage 3 description, which specifies the encoding rules for the information flows and process behaviour for the different entities in the SwMI and in the MS. Charging principles and Man-Machine Interface (MMI) are outside the scope of the present document. The SS-AL enables a served user to place a TETRA Mobile Station (MS) into a special type of voice call whereby the called MS transmits without any action from, or indication to, the affected user. The ambience listening call may include a second listening party.
2 References
The following documents contain provisions which, through reference in this text, constitute provisions of the present document.
- References are either specific (identified by date of publication and/or edition number or version number) or non-specific.
- For a specific reference, subsequent revisions do not apply.
- For a non-specific reference, the latest version applies.
Referenced documents which are not found to be publicly available in the expected location might be found at http://docbox.etsi.org/Reference.
[1] ETSI EN 300 392-2: "Terrestrial Trunked Radio (TETRA); Voice plus Data (V+D); Part 2: Air Interface (AI)".
[2] ETSI EN 300 392-9: "Terrestrial Trunked Radio (TETRA); Voice plus Data (V+D); Part 9: General requirements for supplementary services".
[3] ETSI EN 300 392-12-21: "Terrestrial Trunked Radio (TETRA); Voice plus Data (V+D); Part 12: Supplementary services stage 3; Sub-part 21: Ambience Listening (AL)". [4] ETSI EN 300 392-10-21: "Terrestrial Trunked Radio (TETRA); Voice plus Data (V+D); Part 10: Supplementary services stage 1; Sub-part 21: Ambience Listening (AL)".
3 Definitions and abbreviations
3.1 Definitions
For the purposes of the present document, the following terms and definitions apply:
Ambience Listening (AL) call: call in which ambience listening functionality is requested NOTE: During the AL call, the affected user's MS transmits without any action from, or indication to, the affected user.
affected user: user whom the served user is listening to served user: user who invokes this supplementary service and listens to the affected user ETSI
SIST EN 300 392-11-21 V1.1.1:2003
8 ETSI EN 300 392-11-21 V1.1.1 (2003-04)
second listening party: TETRA individual or group which additionally listens the AL call
3.2 Abbreviations
For the purposes of the present document, the following abbreviations apply:
AL Ambience Listening FE Functional Entity ISI InterSystem Interface ITSI Individual TETRA Subscriber Identity MS Mobile Station SS Supplementary Service NOTE: The abbreviation SS is only used when referring to a specific supplementary service. SwMI Switching and Management Infrastructure
4 Functional model
4.1 Functional model description
The functional model shall comprise the following Functional Entities (FEs):
- FE1 served user's service agent;
- FE2 ambience listening control entity;
- FE5 affected user's service agent;
- FE6 second listening party's service agent.
The following relationships shall exist between these FEs:
- ra between FE1 and FE2;
- rb between FE2 and FE5;
- rc between FE2s in different SwMIs;
- rd between FE2 and FE1 in a visited SwMI;
- re between FE2 in visited SwMI and FE5 in visited SwMI;
- rf between FE6 and FE2;
- rg between FE6 in visited SwMI and FE2 in a visited SwMI.
Figure 1 shows these FEs and their relationships.
NOTE: Served user FE1 and affected user FE5 can be present only once in each instance and figure 1 gives only a general view.
ETSI
SIST EN 300 392-11-21 V1.1.1:2003
9 ETSI EN 300 392-11-21 V1.1.1 (2003-04)
Second Listening Party
SwMI 1 FE6 CCA rf Affected User Served User FE1 ra FE2 FE5 rb CC CCA CCA ISI rc SwMI 2 Served Uset Affected User rd FE5 FE2 FE1 re CC CCA CCA Second Listening Party FE6 rg CCA
Figure 1: Operational and management functional model for SS-AL
4.2 Description of FEs
4.2.1 Served user's agent functional entity, FE1 The function entity FE1 shall:
- receive interrogation and invocation information from the served user and information about the executed service request from FE2 in order to deliver it to the served user. 4.2.2 AL control functional entity in home SwMI, FE2 The functional entity FE2 shall:
- perform checks and actions for the data received for interrogation and invocation;
- provide the affected user's application with applicable SS-AL data by sending it to the affected user's service agent FE5 via visited system FE2 if the affected user is located in a different system;
- provide the served user's agent functional entity with the acknowledgement or rejection of the requested service. This is sent via visited system SwMI FE2 if the served user is in visited system;
- given that a second listening party is involved in the AL call, provide the second listening party's application with applicable SS-AL data by sending it to the second listening party's service agent FE6 via visited system SwMI FE2 if the second listening party is located in a different system;
- if any exception conditions are noticed by SwMI, FE2 shall take appropriate action;
- optionally clear down the AL call if a new incoming call is received for the affected user. ETSI
SIST EN 300 392-11-21 V1.1.1:2003
10 ETSI EN 300 392-11-21 V1.1.1 (2003-04)
4.2.3 Affected user's agent functional entity, FE5 The functional entity FE5 shall:
- receive information of the new AL invocation;
- disable user notification of the call with which AL is invoked. The functional entity FE5 should clear down the AL call if the affected user attempts to make a new call, normal call disconnection procedures shall apply to the AL call, as specified in EN 300 392-2 [1]. When the AL call ends FE5 reverts to normal operation.
In one SS-AL invocation there may only be one affected user.
4.2.4 AL functional control entity in visited SwMI, FE2 The functional entity FE2 in visited SwMI shall:
- clear down the AL call if a new incoming call is received for the affected user;
- receive information flows from the ambience listening control functional entity, the served user's control functional entity and the affected user's control functional entity. The information flows FE2 in visited SwMI shall be able to receive:
- acknowledgements sent by an affected user located in its system;
- requests and responses sent by ambience listening control entity in SS-AL home system;
- requests sent by a served user located in its system.
FE2 in visited SwMI shall send information flows to their recipient:
- the affected user that is currently in this system for SS-AL invocation;
- the SS-AL control entity for the responses sent by the affected user;
- the served user that is currently in this system for SS-AL interrogation and invocation;
- the second listening party that is currently in this system for SS-AL information. 4.2.5 Second listening party's agent functional entity, FE6 The functional entity FE6 shall: receive an information flow for the new AL call set-up.
5 Information flows
5.1 Definition of information flows
In the tables listing the element type indicates whether the information element is Mandatory (M) or optional (O).
5.1.1 AL-TX DEMAND
AL-TX DEMAND is an optional information flow for the routes ra, rc and rd from FE1 to FE2. The flow is sent to FE2 (group controlling SwMI) via FE2 in visited SwMI if FE1 is in a visited system. The flow is used to invoke AL-listening for a specified individual user during ongoing group call. Table 1 lists the elements within the AL-TX DEMAND information flow.
ETSI
SIST EN 300 392-11-21 V1.1.1:2003
11 ETSI EN 300 392-11-21 V1.1.1 (2003-04)
Table 1: Content of AL-TX DEMAND information flow Element Type Affected user identity M TX demand priority M Encryption control M
NOTE: Addition of other second listening parties, than those already in the ongoing call, is outside the scope of the present document.
5.1.2 AL-TX GRANTED
AL-TX GRANTED is an optional information flow for routes rb, rc and re from FE2 to FE5. The flow is sent to FE5 via FE2 in visited SwMI, if FE5 is in that visited system. The flow is used to invoke AL-transmission for the specified individual user during ongoing group call. Table 2 lists the elements within the AL-TX GRANTED information flow. Table 2: Contents of AL-TX GRANTED information flow Element Type Transmission grant M, note Encryption control M NOTE: Only value "Transmission granted" is applicable.
5.1.3 AL-TX INFORM
AL-TX INFORM is an optional information flow for the routes rf, rc and rg from FE2 to FE6. The flow is sent via FE2 in visited SwMI, if FE6 is in the visited system. The AL-TX INFORM indicates that the current speech item is an AL-speech item. Table 3 lists the elements within the AL-TX INFORM information flow. Table 3: Contents of AL-TX INFORM information flow Element Type Affected user identity M Listening party identity O
5.1.4 AL-TX INTERRUPT
AL-TX INTERRUPT is an optional information flow for the routes ra, rc and rd from FE1 to FE2. The flow is sent via FE2 in visited SwMI, if FE1 is in the visited system. The flow is used to stop AL-transmission for a specified individual during ongoing group call. Table 4 lists the elements within the AL-TX INTERRUPT information flow. Table 4: Content of AL-TX INTERRUPT information flow Element Type Affected user identity M
ETSI
SIST EN 300 392-11-21 V1.1.1:2003
12 ETSI EN 300 392-11-21 V1.1.1 (2003-04)
5.1.5 AL-TX REJECT
AL-TX REJECT is an optional information flow for the routes ra, rc and rd from FE2 to FE1. The flow is sent to FE1 via FE2 in visited SwMI if FE1 is in a visited system. The flow is used to give reason why the AL-listening invocation for a specified individual user during ongoing group call failed. Table 5 lists the elements within the AL-TX REJECT information flow.
Table 5: Contents of AL-TX REJECT information flow Element Type Remark Rejection Cause M rejected for undefined reason; accepted; service not supported; user not authorized; affected user busy; unknown TETRA identity.
5.1.6 INFORMATION
INFORMATION is an optional information flow for the routes rc, rf and rg from FE2 to FE6. The flow is sent to FE6 via FE2 in visited SwMI if FE6 is in a visited system. The flow is used to inform a second listening party that the incoming call is an AL call. Table 6 lists the elements within the INFORMATION information flow. Table 6: Content of INFORMATION information flow Element Type Affected user identity M
5.1.7 INTERROGATE
INTERROGATE is an optional information flow for the routes ra, rc and rd from FE1 to FE2. The flow is sent to FE2 via FE2 in visited SwMI if FE1 is in a visited system. The flow is used to interrogate the SS-AL for a specified individual, a list of individuals or a range of individuals. Table 7 lists the elements within the INTERROGATE information flow.
Table 7: Content of INTERROGATE information flow Element Type Remarks Interrogated subscribers identity(s) M This may be a single identity, a list or a range of identities.
ETSI
SIST EN 300 392-11-21 V1.1.1:2003
13 ETSI EN 300 392-11-21 V1.1.1 (2003-04)
5.1.8 INTERROGATE ACK
INTERROGATE ACK is an optional information flow for the routes ra, rc and rd from FE2 to FE1. The flow is sent to FE1 via FE2 in visited SwMI if FE1 is in a visited system. The flow is used to acknowledge an interrogation request for a specified individual, a list of individuals or a range of individuals. Table 8 lists the elements within the INTERROGATE ACK information flow.
If INTERROGATE is supported then support of the INTERROGATE ACK is mandatory. Table 8: Content of INTERROGATE ACK information flow Element Type Remarks Interrogated subscribers identity(s) M This may be a single identity, a list or a range of identities Result M rejected for undefined reason; SS-AL invoked for the TETRA identity, SS-AL not invoked for the TETRA identity; user not authorized; unknown TETRA identity; parameters not valid; or insufficient information.
5.1.9 INVOKE1 INVOKE1 s an optional information flow for the routes ra, rc and rd from FE1 to FE2. The flow is sent to FE2 via FE2 in visited SwMI if FE1 is in a visited system. The flow is used to request invocation of SS-AL for a specified individual. Table 9 lists the elements within the INVOKE1 information flow. Table 9: Content of INVOKE1 information flow Element Type Affected user identity M
5.1.10 INVOKE2 INVOKE2 is an optional information flow for the routes ra, rc and rd from FE1 to FE2. The flow is sent to FE2 via FE2 in visited SwMI if FE1 is in a visited system. The flow is used to include a second listening party into an ongoing AL call. Table 10 lists the elements within the INVOKE2 information flow. Table 10: Content of INVOKE2 information flow Element Type Second listening party identity M
...
Contents
- 1 Scope
- 2 Normative references
- 3 Definitions and abbreviations
- 3.1 Definitions
- 3.2 Abbreviations
- 4 Supplementary Service Ambience Listening (SS-AL) Stage 2 specification
- 4.1 Functional model
- 4.2 Information flows
- 4.3 Allocation of FEs to physical equipment
- 4.4 Inter-working considerations
1 Scope
This European Telecommunication Standard (ETS) defines the stage 2 specification of the Supplementary Service Ambience Listening (SS-AL) for the Trans-European Trunked Radio (TETRA) as provided by European operators. Stage 2 identifies the functional entities involved in the supplementary service and the information flows between them.
Charging principles and Man-Machine Interface (MMI) are outside the scope of this ETS. The SS-AL enables a served user to place a TETRA Mobile Station (MS) or Line Station (LS) into a special type of voice call teleservice whereby the called MS (or LS) transmits without any action from, or indication to, the affected user. The teleservice may include a second listening party.
2 Normative references
This ETS incorporates, by dated or undated reference, provisions from other publications. These†normative references are cited at the appropriate places in the text and the publications are listed hereafter. For dated references, subsequent amendments to, or revisions of, any of these publications apply to this ETS only when incorporated in it by amendment or revision. For undated references the latest edition of the publication referred to applies.
[1] CCITT Recommendation I.130 (1988): "Method for the characterization of telecommunication services supported by an ISDN and network capabilities of an ISDN".
[2] ETS 300 392-2: "Radio Equipment and Systems (RES); Trans-European Trunked Radio (TETRA); Voice plus Data (V+D); Part 2: Air Interface (AI)". [3] ETS 300 392-1: "Radio Equipment and Systems (RES); Trans-European Trunked Radio (TETRA); Voice plus Data (V+D); Part 1: General Network Design".
[4] ITU-T Recommendation Z.100 (1993): "Specification and Description Language (SDL)".
3 Definitions and abbreviations
3.1 Definitions
For the purposes of this ETS, the following definitions apply:
AL call: A call in which ambience listening functionality is requested. During the AL call, the affected user's MS (or LS) transmits without any action from, or indication to, the affected user. affected user: The user who is subject to the operation.
served user: The user who is invoking this supplementary service. second listening party: A TETRA individual or group which may listen into the AL call.
SIST EN 300 392-11-21 V1.1.1:2003 Page 8 Draft prETS 300 392-11-21: September 1996
3.2 Abbreviations
For the purposes of this ETS, the following abbreviations apply:
AL Ambience Listening CC Call Control CCA Call Control (functional entity Agent) FE Functional Entity GTSI Group TETRA Subscriber Identity ISDN Integrated Services Digital Network ITSI Individual TETRA Subscriber Identity LS Line Station MS Mobile Station SDL (Functional) Specification and Description Language SS Supplementary Service NOTE: The abbreviation SS is only used when referring to a specific supplementary service. SwMI Switching and Management Infrastructure TETRA Trans-European Trunked Radio
4 Supplementary Service Ambience Listening (SS-AL) Stage 2 specification
4.1 Functional model
4.1.1 Functional model description
The functional model shall comprise the following Functional Entities (FEs):
- FE1 served user's service agent;
- FE2 ambience listening control entity in the served user's home system;
- FE3 affected user's service agent;
- FE4 generic functional control entity in a visited system with respect to the served user;
- FE5 second listening party's service agent.
The following relationships shall exist between these FEs:
- ra between FE1 and FE2;
- rb between FE2 and FE3;
- rc between FE2 and FE4 in different systems;
- rd between FE4 and FE1;
- re between FE4 and FE3;
- rf between FE5 and FE2;
- rg between FE5 and FE4.
Figure 1 shows these FEs and their relationships.
SIST EN 300 392-11-21 V1.1.1:2003 Page 9 Draft prETS 300 392-11-21: September 1996 Second Listening Party SYSTEM 1 FE5 CCA rf Affected User Served User FE1 ra FE2 FE3 rb CC CCA CCA ISI rc SYSTEM 2 Served User Affected User rd FE3 FE4 FE1 re CC CCA CCA Second Listening Party FE5 rg CCA Figure 1: Operational and management functional model for SS-AL
4.1.2 Description of FEs
4.1.2.1 Served user's agent functional entity, FE1 The function entity FE1 shall: receive interrogation and invocation information from the served user and information (positive or negative acknowledgements) about the executed service request from FE2 in order to deliver it to the served user.
4.1.2.2 AL control functional entity, FE2 The functional entity FE2 shall:
- perform checks, give instructions and perform actions for the data received for interrogation and invocation;
- construct and deliver the PDUs;
- provide the affected user's application with applicable SS-AL data by sending it to the affected user's service agent FE3 via FE4 if the affected user is located in a different system;
- provide the served user's agent functional entity with the positive or negative acknowledgement of the requested service. This is sent to FE4 if the served user is in visited system;
- given that a second listening party is involved in the AL call, provide the second listening party's application with applicable SS-AL data by sending it to the second listening party's service agent FE5 via FE4 if the second listening party is located in a different system;
- if any exception conditions are noticed by SwMI, FE2 stops the execution of the service request and the AL call will be cleared down;
- clear down the AL call if a new incoming call is received for the affected user.
SIST EN 300 392-11-21 V1.1.1:2003 Page 10 Draft prETS 300 392-11-21: September 1996 4.1.2.3 Affected user's agent functional entity, FE3 The functional entity FE3 shall:
- receive information of the new AL invocation.;
- disable user notification of the call with which AL is invoked. The functional entity FE3 may:
- clear down the AL call if the affected user attempts to make a new call, normal call disconnection procedures shall apply to the AL call, as specified in ETS 300 392-2 [2];
- when the AL call ends FE3 reverts to normal operation;
- in one SS-AL invocation there may only be one affected user. 4.1.2.4 Generic functional control entity, FE4 The functional entity FE4 shall:
- clear down the AL call if a new incoming call is received for the affected user;
- receive information flows from the ambience listening control functional entity, the served user's control functional entity and the affected user's control functional entity. The information flows FE4 shall be able to receive:
- acknowledgements sent by an affected user located in its system;
- requests and responses sent by ambience listening control entity in SS-AL home system;
- requests sent by a served user located in its system.
FE4 adds the applicable addressing information to the information flows and they are sent to their recipient:
- the affected user that is currently in this system for SS-AL invocation;
- the SS-AL control entity for the responses sent by the affected user;
- the served user that is currently in this system for SS-AL interrogation and invocation;
- the second listening party that is currently in this system for SS-AL information. 4.1.2.5 Second listening party's agent functional entity, FE5 The functional entity FE5 shall: receive an information flow for the new AL call set-up.
4.2 Information flows
4.2.1 Definition of information flows
In the tables listing the element type indicates whether the data type is Mandatory (M) or optional (O).
4.2.1.1 Interrogation
SIST EN 300 392-11-21 V1.1.1:2003 Page 11 Draft prETS 300 392-11-21: September 1996 4.2.1.1.1 INTERROGATE-REQUEST This shall be an information flow for the routes ra, rc and rd from FE1 to FE2. The flow shall be sent to FE2 via FE4 if FE1 is in a visited system. The flow is used to interrogate the SS-AL for a specified individual, a list of individuals or a range of individuals. Table 1 lists the elements within the INTERROGATE-REQUEST information flow.
Table 1: Content of INTERROGATE-REQUEST Element Type Value Remarks Interrogated Subscribers Identity(s) M This may be a single identity, If range is given, the first and a list or a range of identities the last value is given 4.2.1.1.2 INTERROGATE-RESULT This shall be an information flow for the routes ra, rc and rd from FE2 to FE1. The flow shall be sent to FE1 via FE4 if FE1 is in a visited system. The flow shall be used to acknowledge an interrogation request for a specified individual, a list of individuals or a range of individuals. Table 2 lists the elements within the INTERROGATE-RESULT information flow.
Table 2: Content of INTERROGATE-RESULT Element Type Value Remarks Interrogated Subscribers Identity(s) M This may be a single identity, If range is given, the first and a list or a range of identities the last value is given Result M invoked, Indicates if the interrogation service not defined for the was successful. This value TETRA id., applies to all identities given rejected for any reason, in the field 'Interrogated user not authorized, Subscriber Identity(s)' above unknown TETRA identity, parameters not valid or insufficient information
...