SIST EN ISO 3744:2026
(Main)Acoustics - Determination of sound power levels of noise sources using sound pressure - Engineering methods for an essentially free field over a reflecting plane (ISO 3744:2025, including corrected version 2026-01)
- Abstract
1.1 General
This document specifies methods for determining the sound power level of a noise source from sound pressure levels measured on a surface enveloping the noise source (machinery or equipment) in an environment that approximates to an acoustic free field near one or more reflecting planes. The sound power level produced by the noise source, in frequency bands or with A-weighting applied, is calculated using those measurements.
NOTE Differently shaped measurement surfaces can yield differing estimates of the sound power level of a given noise source which are accounted for in the uncertainty associated with this test method. An appropriately drafted noise test code (see ISO 12001) gives detailed information on the selection of the surface.
1.2 Types of noise and noise sources
The methods specified in this document are suitable for all types of noise (steady, non-steady, and fluctuating) as defined in ISO 12001, except for short duration, impulsive events.
This document is applicable to all types and sizes of noise source (e.g. stationary or slowly moving component or sub-assembly), provided that the conditions for the measurements can be met.
NOTE It is possible that the conditions for measurements given in this document are impracticable for very tall or very long sources such as chimneys, ducts, conveyors and multi-source industrial plants. A noise test code for the determination of noise emission of specific sources can provide alternative methods in such cases.
1.3 Test environment
The test environments that are applicable for measurements made in accordance with this document can be located indoors or outdoors, with one or more sound-reflecting planes present on or near which the noise source under test is mounted. The ideal environment is a completely open space with no bounding or reflecting surfaces other than the reflecting plane(s), such as that provided by a qualified hemi-anechoic chamber, but procedures are given for applying corrections (within limits that are specified) in the case of environments that are less than ideal. Annex A or ISO 26101-2 specifies methods for determining the adequacy of the test environment and for determination of corrections to be applied to account for the effect of the test environment.
1.4 Measurement uncertainty
Information is given on the uncertainty of the sound power levels determined in accordance with this document, for measurements made in limited bands of frequency and with frequency A-weighting applied. Annex I specifies procedures for testing laboratories that can be used to reduce measurement uncertainty. The uncertainty conforms to ISO 12001, accuracy grade 2 (engineering grade). General information on measurement uncertainty is provided in this document and additional information can be found in ISO 5114-1[8].
- Status
- Published
- Public Enquiry End Date
- 23-Mar-2023
- Publication Date
- 14-Jun-2026
- Technical Committee
- AKU - Acoustics
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 08-Jun-2026
- Due Date
- 13-Aug-2026
- Completion Date
- 15-Jun-2026
- Directive
- 2006/42/EC - Directive 2006/42/EC of the European Parliament and of the Council of 17 May 2006 on machinery, and amending Directive 95/16/EC (recast)OJ Ref: L 7.9.2026 OJ Date: 07-Sep-2026
SIST EN ISO 3744:2026 is the Slovenian standard published by SIST as the national adoption of EN ISO 3744:2026, reproducing ISO 3744:2025 including the corrected version 2026-01. It specifies engineering methods for determining sound power levels of machinery and equipment from sound pressure measurements on an enveloping surface in an environment that approximates an acoustic free field over a reflecting plane. It is used by test laboratories, manufacturers, and others who need engineering-grade noise emission results for declaration, verification, or product development.
What does SIST EN ISO 3744:2026 specify?
SIST EN ISO 3744:2026 specifies how to determine the sound power level of a noise source from sound pressure levels measured on a surface surrounding the source. The method applies to sources mounted near one or more reflecting planes, indoors or outdoors, and gives results in frequency bands or as A-weighted values.
The document covers steady, non-steady, and fluctuating noise, but not short duration impulsive events. It is intended for all types and sizes of noise source, including machinery, equipment, and sub-assemblies, provided the measurement conditions can be met.
The document is organized into main clauses on scope, references, terms, test environment, instrumentation, source installation and operation, reference boxes and measurement surfaces, sound power calculation, uncertainty, records, and the test report. It also includes nine annexes, several of them normative.
| Annex | What it covers |
|---|---|
| Annex A | Qualification procedures for the acoustic environment and measurement surface |
| Annex B | Microphone arrays on a hemispherical measurement surface |
| Annex C | Microphone arrays on a parallelepiped measurement surface |
| Annex D | Microphone arrays on a cylindrical measurement surface |
| Annex E | Measurement surfaces with unequal segment areas |
| Annex F | Alternative hemispherical array for direct A-weighted measurements |
| Annex G | Calculation of A-weighted sound power levels from frequency band levels |
| Annex H | Sound power levels under reference meteorological conditions |
| Annex I | Laboratory procedures to reduce uncertainty |
What are the key requirements of SIST EN ISO 3744:2026?
SIST EN ISO 3744:2026 is built around a simple sequence: qualify the test environment, set up the source in a defined way, measure sound pressure on a prescribed surface, apply the required corrections, and report the resulting sound power level with uncertainty. In practice, the standard tells you what environment is acceptable, how to arrange microphones, and what to record so the result can be repeated.
Test environment and background noise
SIST EN ISO 3744:2026 requires a test environment that is close to an acoustic free field over a reflecting plane. The ideal case is a fully open space or a qualified hemi-anechoic chamber, but the standard also allows corrections when the environment is not ideal, provided the environmental correction stays within the limit for use of the method.
This matters because room reflections can bias the result. The document therefore separates the qualification of the environment from the measurement itself, and it points users to Annex A or ISO 26101-2 for determining the environmental correction.
Instrumentation and checks
SIST EN ISO 3744:2026 requires class 1 sound level measurement equipment for the relevant parameters, class 1 filters, and a class 1 sound calibrator. The beginning and end of each measurement session shall be checked, and the difference between two consecutive checks shall be within 0.5 dB.
This matters in practice because unstable instrumentation can invalidate a test day. The document also requires verification of the measuring system, filters, and calibrator through valid conformity evidence and conformance testing in an ISO/IEC 17025 laboratory.
Source installation and operation
SIST EN ISO 3744:2026 requires the noise source to be installed and operated as it would be in normal use, while following any applicable noise test code. Auxiliary equipment, piping, ducts, and connections must not add significant sound of their own, and the source under test must include any auxiliary equipment that cannot be removed or adequately quietened.
This is important because setup choices can change the measured sound power. For moving sources, the source traverses a defined straight path. For all sources, the operating mode should be reproducible and representative of the noisiest typical use, such as full load, idling, maximum speed, or a defined work cycle.
Reference box and measurement surfaces
SIST EN ISO 3744:2026 first defines a reference box that just encloses the source, then uses that box to choose the measurement surface. The permitted measurement surfaces are hemispherical, parallelepiped, cylindrical, and combination surfaces.
This matters because the surface shape changes the measurement geometry and the uncertainty. The standard uses the characteristic source dimension, measurement distance, and measurement radius to place microphones or traverses. Annexes B, C, and D provide the arrays for the main surface types, and Annex F provides an alternative hemispherical array for direct A-weighted measurements.
Sound power calculation and corrections
SIST EN ISO 3744:2026 calculates sound power from the mean sound pressure level over the measurement surface, with corrections for background noise and the test environment. If the measurement surface has unequal segment areas, Annex E gives the averaging method. If results are reported in bands, Annex G gives the calculation of A-weighted sound power from band data.
This matters because the standard is not just a measurement layout - it defines how to turn measured pressures into a final sound power level. Annex H gives the adjustment to reference meteorological conditions, which is relevant at higher altitudes and in low-temperature conditions.
Uncertainty, records, and report
SIST EN ISO 3744:2026 treats uncertainty as part of the result. It uses the total standard deviation and expanded measurement uncertainty, with typical values given for engineering-grade work, and Annex I offers a laboratory route to lower uncertainty.
The standard also requires recording the source, test environment, instrumentation, acoustical data, and corrections, then reporting enough detail to reproduce the test. If the result is fully in conformity, the report may say so; if not, it must not imply full conformity.
What terms does SIST EN ISO 3744:2026 define?
- Sound pressure - the difference between instantaneous total pressure and static pressure, expressed in pascals.
- Sound pressure level - the logarithmic level derived from root-mean-square sound pressure relative to 20 µPa.
- Reference box - the smallest right parallelepiped that just encloses the source, including significant radiating parts and any test table.
- Characteristic source dimension, d - the distance from the coordinate origin to the farthest corner of the reference box.
- Measurement surface - the hypothetical surface on which microphone positions are located around the source for sound pressure measurement.
- Background noise correction, K - the correction applied to account for noise from other sources and instrumentation.
- Environmental correction, K - the correction applied to account for reflected or absorbed sound from the test environment.
- Noise test code - a source-specific standard that gives the information needed to carry out noise emission measurements under standardized conditions.
Who uses SIST EN ISO 3744:2026?
SIST EN ISO 3744:2026 is used by manufacturers of machinery and equipment, acoustic test laboratories, quality and compliance teams, and engineers who need sound power data for product design or comparison. It is also relevant to buyers and specifiers who rely on declared noise emission values.
The standard is especially relevant where noise emission has to be measured in a controlled engineering way, rather than by a quick survey method. The European foreword also links it to the machinery directive context, so it is used in work connected with noise-related essential requirements for machinery.
What changed in SIST EN ISO 3744:2026 from the previous edition?
SIST EN ISO 3744:2026 supersedes EN ISO 3744:2010 and reflects the fourth edition of ISO 3744.
The changes stated in the document include:
- removal of sound energy level determination
- movement of many special-case conditions and parameters into annexes
- replacement of absolute background noise criteria with background noise conformity criteria
- removal of methods for estimating K from equivalent sound absorption area
- revised instrumentation requirements for modern modular computerized systems
- updated cylinder requirements aligned with ISO 7779
- transfer of some test-environment qualification methods to ISO 26101-2
- new Annex I procedures to reduce measurement uncertainty
- clarification of cylindrical measurement-surface measurements
- correction of formulae in Figures C.3 and C.4 in the corrected version
The document also states that the basic measurement procedure and reproducibility for the main method remain unchanged from the 2010 version.
Which standards are used with SIST EN ISO 3744:2026?
SIST EN ISO 3744:2026 relies on several normative references and companion standards:
- ISO 3745 - used for precision methods and for qualifying hemi-anechoic environments
- ISO 6926 - used for performance and calibration of reference sound sources
- ISO 26101-1 - used for qualification of free-field environments
- ISO 26101-2 - used for environmental correction and qualification methods
- ISO 12001 - used for noise test codes and general noise-emission measurement rules
- IEC 60942 - used for sound calibrators
- IEC 61260-1, IEC 61260-2, IEC 61260-3 - used for octave-band and fractional-octave-band filters
- IEC 61672-1, IEC 61672-3 - used for sound level meters and their periodic tests
- ISO/IEC 17025 - used for laboratory competence
- ISO 5114-1 - gives additional guidance on uncertainty associated with sound power measurements from sound pressure data
The document also points to the ISO 3740 to ISO 3747 series and to ISO 9614-1, ISO 9614-2, and ISO 9614-3 when different methods or higher accuracy are needed.
What does the SIST EN ISO 3744:2026 document contain?
SIST EN ISO 3744:2026 contains detailed measurement surfaces, microphone arrays, and calculation procedures for hemispherical, parallelepiped, cylindrical, and combination arrangements. The annexes provide tables and figures that define microphone coordinates, traversing paths, and how to treat unequal surface areas.
It also includes the procedure for the absolute comparison test, the calculation of A-weighted sound power from frequency bands, and the adjustment to reference meteorological conditions. These parts are used for test development, laboratory setup, compliance testing, and the preparation of reproducible noise reports.
Relations
- Effective Date
- 01-Jul-2026
- Referred By
SIST EN 18142:2027 - Self-loading mobile concrete mixers - Safety requirements and verification - Effective Date
- 25-Nov-2026
- Effective Date
- 11-Nov-2026
- Effective Date
- 18-Mar-2026
- Effective Date
- 18-Mar-2026
- Effective Date
- 18-Mar-2026
- Referred By
SIST EN 13378:2002 - Pasta processing plants - Pasta presses - Safety and hygiene requirements - Effective Date
- 18-Mar-2026
- Effective Date
- 18-Mar-2026
- Referred By
SIST EN 1886:2008 - Ventilation for buildings - Air handling units - Mechanical performance - Effective Date
- 18-Mar-2026
- Effective Date
- 18-Mar-2026
- Effective Date
- 18-Mar-2026
- Effective Date
- 18-Mar-2026
- Effective Date
- 18-Mar-2026
- Effective Date
- 18-Mar-2026
- Effective Date
- 18-Mar-2026
Get Certified
Connect with accredited certification bodies for this standard
BSMI (Bureau of Standards, Metrology and Inspection)
Taiwan's standards and inspection authority.
Sponsored listings
Frequently Asked Questions
SIST EN ISO 3744:2026 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Acoustics - Determination of sound power levels of noise sources using sound pressure - Engineering methods for an essentially free field over a reflecting plane (ISO 3744:2025, including corrected version 2026-01)". This standard covers: 1.1 General This document specifies methods for determining the sound power level of a noise source from sound pressure levels measured on a surface enveloping the noise source (machinery or equipment) in an environment that approximates to an acoustic free field near one or more reflecting planes. The sound power level produced by the noise source, in frequency bands or with A-weighting applied, is calculated using those measurements. NOTE Differently shaped measurement surfaces can yield differing estimates of the sound power level of a given noise source which are accounted for in the uncertainty associated with this test method. An appropriately drafted noise test code (see ISO 12001) gives detailed information on the selection of the surface. 1.2 Types of noise and noise sources The methods specified in this document are suitable for all types of noise (steady, non-steady, and fluctuating) as defined in ISO 12001, except for short duration, impulsive events. This document is applicable to all types and sizes of noise source (e.g. stationary or slowly moving component or sub-assembly), provided that the conditions for the measurements can be met. NOTE It is possible that the conditions for measurements given in this document are impracticable for very tall or very long sources such as chimneys, ducts, conveyors and multi-source industrial plants. A noise test code for the determination of noise emission of specific sources can provide alternative methods in such cases. 1.3 Test environment The test environments that are applicable for measurements made in accordance with this document can be located indoors or outdoors, with one or more sound-reflecting planes present on or near which the noise source under test is mounted. The ideal environment is a completely open space with no bounding or reflecting surfaces other than the reflecting plane(s), such as that provided by a qualified hemi-anechoic chamber, but procedures are given for applying corrections (within limits that are specified) in the case of environments that are less than ideal. Annex A or ISO 26101-2 specifies methods for determining the adequacy of the test environment and for determination of corrections to be applied to account for the effect of the test environment. 1.4 Measurement uncertainty Information is given on the uncertainty of the sound power levels determined in accordance with this document, for measurements made in limited bands of frequency and with frequency A-weighting applied. Annex I specifies procedures for testing laboratories that can be used to reduce measurement uncertainty. The uncertainty conforms to ISO 12001, accuracy grade 2 (engineering grade). General information on measurement uncertainty is provided in this document and additional information can be found in ISO 5114-1[8].
1.1 General This document specifies methods for determining the sound power level of a noise source from sound pressure levels measured on a surface enveloping the noise source (machinery or equipment) in an environment that approximates to an acoustic free field near one or more reflecting planes. The sound power level produced by the noise source, in frequency bands or with A-weighting applied, is calculated using those measurements. NOTE Differently shaped measurement surfaces can yield differing estimates of the sound power level of a given noise source which are accounted for in the uncertainty associated with this test method. An appropriately drafted noise test code (see ISO 12001) gives detailed information on the selection of the surface. 1.2 Types of noise and noise sources The methods specified in this document are suitable for all types of noise (steady, non-steady, and fluctuating) as defined in ISO 12001, except for short duration, impulsive events. This document is applicable to all types and sizes of noise source (e.g. stationary or slowly moving component or sub-assembly), provided that the conditions for the measurements can be met. NOTE It is possible that the conditions for measurements given in this document are impracticable for very tall or very long sources such as chimneys, ducts, conveyors and multi-source industrial plants. A noise test code for the determination of noise emission of specific sources can provide alternative methods in such cases. 1.3 Test environment The test environments that are applicable for measurements made in accordance with this document can be located indoors or outdoors, with one or more sound-reflecting planes present on or near which the noise source under test is mounted. The ideal environment is a completely open space with no bounding or reflecting surfaces other than the reflecting plane(s), such as that provided by a qualified hemi-anechoic chamber, but procedures are given for applying corrections (within limits that are specified) in the case of environments that are less than ideal. Annex A or ISO 26101-2 specifies methods for determining the adequacy of the test environment and for determination of corrections to be applied to account for the effect of the test environment. 1.4 Measurement uncertainty Information is given on the uncertainty of the sound power levels determined in accordance with this document, for measurements made in limited bands of frequency and with frequency A-weighting applied. Annex I specifies procedures for testing laboratories that can be used to reduce measurement uncertainty. The uncertainty conforms to ISO 12001, accuracy grade 2 (engineering grade). General information on measurement uncertainty is provided in this document and additional information can be found in ISO 5114-1[8].
SIST EN ISO 3744:2026 is classified under the following ICS (International Classification for Standards) categories: 17.140.01 - Acoustic measurements and noise abatement in general. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN ISO 3744:2026 has the following relationships with other standards: It is inter standard links to SIST EN ISO 3744:2010, SIST EN 18142:2027, SIST EN 14238:2026, SIST EN 17242:2026, SIST EN 14673:2007+A1:2010, SIST EN 60704-1:2010, SIST EN 13378:2002, SIST EN 13053:2007+A1:2011, SIST EN 1886:2008, SIST EN 12733:2018, SIST EN 12549:2000+A1:2008, SIST EN 12599:2013, SIST EN IEC 63341-3:2026, SIST EN 13732:2013, SIST EN 14466:2005+A1:2009. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
SIST EN ISO 3744:2026 is associated with the following European legislation: EU Directives/Regulations: 2006/42/EC; Standardization Mandates: M/396. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
SIST EN ISO 3744:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- Introduction
- 1 Scope
- 1.1 General
- 1.2 Types of noise and noise sources
- 1.3 Test environment
- 1.4 Measurement uncertainty
- 2 Normative references
- 3 Terms and definitions
- 3.1 sound pressure
- 3.2 sound pressure level
- 3.3 measurement time interval
- 3.4 acoustic free field
- 3.5 acoustic free field over a reflecting plane
- 3.6 reflecting plane
- 3.7 frequency range of interest
- 3.8 reference box
- 3.9 characteristic source dimension
- 3.10 measurement distance
- 3.11 measurement radius
- 3.12 measurement surface
- 3.13 background noise
- 3.14 background noise correction
- 3.15 environmental correction
- 3.16 surface sound pressure level
- 3.17 sound power
- 3.18 sound power level
- 3.19 noise test code
- 4 Test environment
- 4.1 General
- 4.2 Criterion for acoustic adequacy of test environment
- 4.3 Criterion for environmental correction
- 4.4 Criteria for background noise
- 5 Instrumentation
- 5.1 General
- 5.2 Operational check
- 5.3 Verification
- 6 Definition, location, installation, and operation of noise source under test
- 6.1 General
- 6.2 Auxiliary equipment
- 6.3 Noise source location
- 6.4 Mounting of the noise source
- 6.5 Installation and mounting conditions for moving noise sources
- 6.6 Operation of source during test
- 7 Reference box and measurement surface
- 7.1 Reference box
- 7.2 Measurement surface
- 8 Determination of sound power levels
- 8.1 Microphone positions on the measurement surface
- 8.2 Determination of sound power levels
- 9 Measurement uncertainty
- 9.1 Methodology
- 9.2 Typical values of σ
- 9.3 Determination of σ
- 9.4 Total standard deviation σ and expanded measurement uncertainty, U
- 10 Information to be recorded
- 10.1 General
- 10.2 Noise source under test
- 10.3 Test environment
- 10.4 Instrumentation
- 10.5 Acoustical data
- 11 Test report
- Annex A
- 2 W W RSS
- Annex B
- Annex C
- Annex D
- Annex E
- Annex F
- Annex G
- Annex H
- Annex I
- Bibliography
Introduction
[2]to[6] This document is one of the series ISO 3741 to ISO 3747 which specify various methods for determining the sound power levels of noise sources including machinery, equipment and their sub-assemblies. General [1] guidelines to assist in the selection are provided in ISO 3740 . The selection depends on the available test environment and on the precision of the sound power level values required. A noise test code can be established (see ISO 12001) for the individual noise source in order to select the appropriate sound [2] measurement surface and microphone array from among those allowed in each member of the ISO 3741 [6] to ISO 3747 series, and to give requirements on test unit mounting, loading and operating conditions under which the sound power levels are to be obtained. The sound power emitted by a given source into the test environment is calculated from the mean square sound pressure that is measured over a hypothetical measurement surface enclosing the source, and the area of that surface. The methods specified in this document permit the determination of the A-weighted sound power level and optionally the sound power level in octave or 1/3-octave frequency bands. The main body of this document specifies test environment qualification criteria, testing procedures and the associated measurement uncertainties for basic compliance with the method. Annex I specifies additional requirements that may be applied by testing laboratories to reduce measurement uncertainty. [2] For applications where even greater accuracy is required, reference can be made to ISO 3745, ISO 3741 or [9][10][11] ISO 9614 . If the relevant criteria for the measurement environment specified in this document are [9][10][11] not met, it might be possible to refer to another standard from this series, or to ISO 9614 . This document specifies methods of accuracy grade 2 (engineering grade) as defined in ISO 12001, when the measurements are performed in a space that approximates an acoustically free field over a reflecting plane. Such an environment can be found in a specially designed room, or within industrial buildings or outdoors. Ideally, the test source should be mounted on a sound-reflecting plane located in a large open space. For sources normally installed on the floor of machine rooms, corrections are specified to account for undesired reflections from nearby objects, walls and ceiling, and for background noises. This test method was originally issued as ISO 4872 in 1978. It was first released as ISO 3744 in 1994. A brief history of the technical requirements associated with the revisions of this test method follows. ISO 3744:1994 required a test environment with a K 2dB in all frequency bands of interest and required 2f measurements to be conducted in octave or one-third octave bands, with A-weighted levels being calculated from the band level data over the frequency range of interest. ISO 3744:2010 relaxed the requirements on the test environment to require K 4dB and allowed 2A A-weighted levels to be determined either by calculation from frequency band level measurements or by direct measurement using an A-weighted filter. These changes to the requirements for the test environment and instrumentation were made to facilitate in-situ and field sound power level determinations using equipment without proportional octave band filtering for evaluation of compliance with regulatory requirements. Round robin studies were conducted to verify that the stated measurement uncertainties [18] associated with the method could be maintained using these requirements . In addition, the 2010 revision added methods for sound energy level determination of short duration transient events, several special case sound power level determination conditions to the main body of the standard and several new measurement parameters.
SIST EN ISO 3744:2026
SIST EN ISO 3744:2026 International Standard ISO 3744:2025(en) Acoustics — Determination of sound power levels of noise sources using sound pressure — Engineering methods for an essentially free field over a reflecting plane
1 Scope
1.1 General
This document specifies methods for determining the sound power level of a noise source from sound pressure levels measured on a surface enveloping the noise source (machinery or equipment) in an environment that approximates to an acoustic free field near one or more reflecting planes. The sound power level produced by the noise source, in frequency bands or with A-weighting applied, is calculated using those measurements.
NOTE Differently shaped measurement surfaces can yield differing estimates of the sound power level of a given noise source which are accounted for in the uncertainty associated with this test method. An appropriately drafted noise test code (see ISO 12001) gives detailed information on the selection of the surface.
1.2 Types of noise and noise sources
The methods specified in this document are suitable for all types of noise (steady, non-steady, and fluctuating) as defined in ISO 12001, except for short duration, impulsive events. This document is applicable to all types and sizes of noise source (e.g. stationary or slowly moving component or sub-assembly), provided that the conditions for the measurements can be met. NOTE It is possible that the conditions for measurements given in this document are impracticable for very tall or very long sources such as chimneys, ducts, conveyors and multi-source industrial plants. A noise test code for the determination of noise emission of specific sources can provide alternative methods in such cases.
1.3 Test environment
The test environments that are applicable for measurements made in accordance with this document can be located indoors or outdoors, with one or more sound-reflecting planes present on or near which the noise source under test is mounted. The ideal environment is a completely open space with no bounding or reflecting surfaces other than the reflecting plane(s), such as that provided by a qualified hemi-anechoic chamber, but procedures are given for applying corrections (within limits that are specified) in the case of environments that are less than ideal. Annex A or ISO 26101-2 specifies methods for determining the adequacy of the test environment and for determination of corrections to be applied to account for the effect of the test environment.
1.4 Measurement uncertainty
Information is given on the uncertainty of the sound power levels determined in accordance with this document, for measurements made in limited bands of frequency and with frequency A-weighting applied. Annex I specifies procedures for testing laboratories that can be used to reduce measurement uncertainty. The uncertainty conforms to ISO 12001, accuracy grade 2 (engineering grade). General information on measurement uncertainty is provided in this document and additional information can be found in [8] ISO 5114-1 .
SIST EN ISO 3744:2026 ISO 3744:2025(en)
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 3745:2012, Acoustics — Determination of sound power levels and sound energy levels of noise sources using sound pressure — Precision methods for anechoic rooms and hemi-anechoic rooms ISO 6926, Acoustics — Requirements for the performance and calibration of reference sound sources used for the determination of sound power levels ISO 26101-1, Acoustics — Test methods for the qualification of the acoustic environment — Part 1: Qualification of free-field environments ISO 26101-2:2024, Acoustics — Test methods for the qualification of the acoustic environment— Part 2:
Determination of the environmental correction ISO 12001, Acoustics — Noise emitted by machinery and equipment — Rules for the drafting and presentation of a noise test code IEC 60942:2017, Electroacoustics — Sound calibrators IEC 61260-1:2014, Electroacoustics — Octave-band and fractional-octave-band filters — Part 1: Specifications IEC 61260-2, Electroacoustics — Octave-band and fractional-octave-band filters — Part 2: Pattern-evaluation tests IEC 61260-3, Electroacoustics — Octave-band and fractional-octave-band filters — Part 3: Periodic tests IEC 61672-1, Electroacoustics — Sound level meters — Part 1: Specifications IEC 61672-3, Electroacoustics — Sound level meters — Part 3: Periodic tests ISO/IEC 17025, General requirements for the competence of testing and calibration laboratories
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:
- ISO Online browsing platform: available at https:// www .iso .org/ obp
- IEC Electropedia: available at https:// www .electropedia .org/
3.1 sound pressure
p difference between instantaneous total pressure and static pressure Note 1 to entry: Sound pressure is expressed in pascals.
[13] [SOURCE: ISO 80000-8:2020 , 8-2.2, modified — Note 1 to entry added.]
3.2 sound pressure level
L p
SIST EN ISO 3744:2026 ISO 3744:2025(en) quantity given by:
p rms L 10lg dB p
p
where p is the root-mean-square sound pressure (3.1) in the time domain and p is the reference value for rms 0 sound pressure (3.1) t
p ptdt rms
T t
and p 20Pa is the reference value of sound pressure (3.1)
Note 1 to entry: If specific frequency and time weightings as specified in IEC 61672-1 and/or specific frequency bands are applied, this is indicated by appropriate subscripts; e.g. L denotes the A-weighted sound pressure level. pA [13] [SOURCE: ISO 80000-8:2020 , 8-14, modified — Deleted remarks and added instead Note 1 to entry and Note 2 to entry.]
3.3 measurement time interval
T portion or a multiple of an operational period or operational cycle of the noise source under test for which the sound pressure level (3.2) is determined Note 1 to entry: Measurement time interval is expressed in seconds.
3.4 acoustic free field
sound field in a homogeneous, isotropic medium free of boundaries Note 1 to entry: In practice, an acoustic free field is a field in which the influence of reflections at the boundaries or other disturbing objects is negligible over the frequency range of interest.
3.5 acoustic free field over a reflecting plane
essentially acoustic free field (3.4) over a reflecting plane in the absence of any other obstacles
3.6 reflecting plane
sound reflecting planar surface on which the noise source under test is located
3.7 frequency range of interest
<general purposes> frequency range of octave bands with nominal mid-band frequencies from 125 Hz to 8 000 Hz (including one-third octave bands with mid-band frequencies from 100 Hz to 10 000 Hz) Note 1 to entry: For special purposes, the frequency range may be extended or reduced, provided that the test environment and instrument specifications are satisfactory for use over the modified frequency range. Changes to the frequency range of interest shall be included in the test report.
3.8 reference box
hypothetical right parallelepiped terminating on the reflecting plane(s) (3.6) on which the noise source under test is located, that just encloses the source including all the significant sound radiating components and any test table on which the source is mounted Note 1 to entry: If required, the smallest possible test table may be used for compatibility with emission sound [12] pressure measurements at bystander positions in accordance with, for example, ISO 11201 .
SIST EN ISO 3744:2026 ISO 3744:2025(en)
3.9 characteristic source dimension
d
distance from the origin of the coordinate system to the farthest corner of the reference box (3.8) Note 1 to entry: Characteristic source dimension is expressed in metres.
3.10 measurement distance
d distance from the reference box (3.8) to a parallelepiped measurement surface or to a cylindrical measurement surface Note 1 to entry: Measurement distance is expressed in metres.
3.11 measurement radius
r radius of a hemispherical measurement surface or a cylindrical measurement surface Note 1 to entry: Measurement radius is expressed in metres.
3.12 measurement surface
hypothetical surface of area, S, on which the microphone positions are located at which the sound pressure levels (3.2) are measured, enveloping the noise source under test and terminating on the reflecting plane(s) (3.6) on which the source is located
3.13 background noise
noise from all sources other than the noise source under test Note 1 to entry: Background noise includes contributions from airborne sound, noise from structure-borne vibration, and electrical noise in the instrumentation.
3.14 background noise correction
K
correction applied to the mean (energy average) of the sound pressure levels (3.2) over all the microphone positions on the measurement surface (3.12), to account for the influence of background noise (3.13) Note 1 to entry: Background noise correction is expressed in decibels. Note 2 to entry: The background noise correction is frequency dependent; the correction in the case of a frequency band is denoted K , where f denotes the relevant mid-band frequency, and that in the case of A-weighting is 1 f denoted K .
1A
3.15 environmental correction
K
correction applied to the mean (energy average) of the sound pressure levels (3.1) over all the microphone positions on the measurement surface (3.12), to account for the influence of reflected or absorbed sound, determined as specified in Annex A or in ISO 26101-2 Note 1 to entry: Environmental correction is expressed in decibels. Note 2 to entry: The environmental correction is frequency dependent; the correction in the case of a frequency band is denoted K , where f denotes the relevant mid-band frequency, and that in the case of overall A-weighting is 2f denoted K , which is determined from A-weighted sound pressure level measurements. 2A Note 3 to entry: In general, the environmental correction depends on the area of the measurement surface and usually K increases with S .
SIST EN ISO 3744:2026 ISO 3744:2025(en) Note 4 to entry: In practice, the K value determined will be a function of both the reflected sound from the test
environment and the shape and arrangement of microphones on the measurement surface used for the K
determination. For the purpose of this document the differences between K values determined with different
measurement surfaces are assumed to be included in the stated measurement uncertainty for the test method.
3.16 surface sound pressure level
L p mean (energy average) of the sound pressure levels (3.2) over all the microphone positions, or traverses, on the measurement surface (3.12), with the background noise correction (3.14), K , and the environmental
correction (3.15), K , applied
Note 1 to entry: Surface sound pressure level is expressed in decibels.
3.17 sound power
P integral over a surface of the product of sound pressure, p , and the component u of the particle velocity in n the direction normal to the surface, at a point on the surface Note 1 to entry: Sound power is expressed in watts.
Note 2 to entry: The quantity relates to the rate per time at which airborne sound energy is radiated by a source. [13] [SOURCE: ISO 80000-8:2020 , 8-9, modified — Symbol W deleted, Notes 1 and 2 to entry added.]
3.18 sound power level
L W quantity given by:
P m L 10lg dB W P
where P is the magnitude of the sound power (3.17) and P 1pW is the reference value of sound power m 0 (3.17) Note 1 to entry: If a specific frequency weighting as specified in IEC 61672-1 and/or specific frequency bands are applied, this is indicated by appropriate subscripts; e.g. L denotes the A-weighted sound power level. WA [13] [SOURCE: ISO 80000-8:2020 , 8-15, modified — Note 1 to entry added.]
3.19 noise test code
standard that is applicable to a particular class, family or type of machinery or equipment, which specifies all of the information necessary to carry out efficiently the determination, declaration and verification of the noise emission characteristics under standardized conditions. [SOURCE: ISO 12001:1996, 3.2, slightly modified — Alternative term C-type standard deleted.]
4 Test environment
4.1 General
The test environments that are applicable for measurements in accordance with this document are:
- a laboratory room or a flat outdoor area which is adequately isolated from background noise (see 4.4) and which provides an acoustic free field over a reflecting plane;
SIST EN ISO 3744:2026 ISO 3744:2025(en) - a room or a flat outdoor area which is adequately isolated from background noise (see 4.4) and in which an environmental correction can be applied to allow for a limited contribution from the reverberant field to the sound pressures on the measurement surface.
Environmental conditions having an adverse effect on the microphones used for the measurements (e.g. strong electric or magnetic fields, wind, impingement of air discharge from the noise source being tested, high or low temperatures) shall be avoided. The instructions of the manufacturer of the measuring instrumentation regarding adverse environmental conditions shall be followed. In an outdoor area, care shall be taken to minimize the effects of adverse meteorological conditions (e.g. temperature, humidity, wind, precipitation) on the sound propagation and on sound generation over the frequency range of interest or on the background noise during the course of the measurements. When a reflecting surface is not a ground plane or is not an integral part of a test room surface, particular care should be exercised to ensure that the plane does not radiate any appreciable sound due to vibrations.
4.2 Criterion for acoustic adequacy of test environment
A test room or outdoor area shall provide a measurement surface that lies inside a sound field that is essentially free of undesired sound reflections from the room boundaries or nearby objects (apart from the floor).
As far as is practicable, the test environment should be free from reflecting objects other than the reflecting plane(s).
An object in the proximity of the noise source under test is considered to be sound reflecting if its width (e.g. diameter of a pole or supporting member) exceeds one-tenth of its distance from the reference box. The reflecting plane(s) shall extend at least 0,5 m beyond the projection of the measurement surface on the plane(s). The sound absorption coefficient of the reflecting plane(s) shall be less than 0,1 over the frequency range of interest.
NOTE 1 Smooth concrete or smooth sealed asphalt surface(s) are generally satisfactory. Annex A specifies the absolute comparison test for determination of the environmental correction K ,
which is the recommended method for qualification of the test environment and accounting for deviations of the test environment from the ideal condition.
The preferred method for determination of K in test environments that are not qualified for K = 0 using 2 2 one of the methods in ISO 26101-1 or ISO 26101-2 is the absolute comparison test specified in Annex A and ISO 26101-2:2024, Clause 5. ISO 26101-2 also specifies procedures for determining the magnitude of the environmental correction, K , including the absolute comparison test and other methods for calculating K 2 2 from measurement of the total sound absorption in the test environment. If the absolute comparison test is not used for the determination of K , then one of the methods specified in ISO 26101-2:2024, Clauses 6 or 7
...