SIST EN 61995-1:2008
(Main)Devices for the connection of luminaires for household and similar purposes -- Part 1: General requirements
Devices for the connection of luminaires for household and similar purposes -- Part 1: General requirements
This part of IEC 61995-1 applies to devices for the connection of luminaires (DCL) intended for household and similar purposes, for the electrical connection of fixed luminaires to final circuits rated at not more than 16 A without providing mechanical support for the luminaire. DCLs are intended for use according to their IP rating per IEC 60529. Outlets have an earthing contact and a rated current of 6 A, plugs are rated at 6 A, unless otherwise specified in the relevant part 2. The rated voltage is 125 V or 250 V at 50/60 Hz. This standard can also be applied to types other than those with standardised interface. DCL plugs and DCL outlets complying with this standard are suitable for use under the following conditions: - an ambient temperature not normally exceeding 25 °C, but occasionally reaching 35 °C; - a temperature not exceeding 70 °C at the terminals of the DCL outlet including the effect of heat generated by the luminaire and the passage of current.
Betriebsmittel für den Anschluss von Leuchten für Haushalt und ähnliche Zwecke -- Teil 1: Allgemeine Anforderungen
Dispositifs de connexion pour luminaires pour usage domestique et analogue -- Partie 1: Exigences générales
La présente partie de la EN 61995 s'applique aux dispositifs de connexion pour luminaires (DCL) prévus pour un usage domestique et analogue, destinés au raccordement de luminaires fixes à des circuits finaux de courant assigné inférieur ou égal à 16 A mais ne comportant pas de support mécanique au luminaire. Les DCL sont destinés à un usage tenant compte de leur degré de protection IP selon la EN 60529.
Elementi za priključitev svetilk za gospodinjstva in podobne namene - 1 del: Splošne zahteve (IEC 61995-1:2005, spremenjen)
Ta del standarda IEC 61995-1 velja za naprave za priključitev svetilk (DCL), namenjene za gospodinjstvo in podobne namene, za električno priključitev vgrajenih svetilk v končna vezja z močjo največ 16 A brez zagotavljanja mehanske podpore za svetilko. DCL-ji so namenjeni uporabi v skladu s svojo stopnjo IP po standardu IEC 60529. Vtičnice imajo kontakt za ozemljitev in naznačeni tok 6 A, vtiči so ocenjeni na 6 A, razen če v ustreznem 2. delu ni določeno drugače. Nazivna napetost je 125 V ali 250 V pri 50/60 Hz. Ta standard se lahko uporablja tudi za druge vrste brez standardiziranega vmesnika. Vtiči DCL in vtičnice DCL, ki so v skladu s tem standardom, so primerni za uporabo pod naslednjimi pogoji: - temperatura okolice, ki običajno ne presega 25 °C, vendar občasno doseže 35 °C; - temperatura, ki ne presega 70 °C na terminalih vtičnice DCL, vključno z učinkom toplote, ki jo povzroči svetilka, in prehodom toka.
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 61995-1:2008
01-julij-2008
(OHPHQWL]DSULNOMXþLWHYVYHWLON]DJRVSRGLQMVWYDLQSRGREQHQDPHQHGHO
6SORãQH]DKWHYH,(&VSUHPHQMHQ
Devices for the connection of luminaires for household and similar purposes - Part 1:
General requirements (IEC 61995-1:2005, modified)
Betriebsmittel für den Anschluss von Leuchten für Haushalt und ähnliche Zwecke - Teil
1: Allgemeine Anforderungen (IEC 61995-1:2005, modifiziert)
Dispositifs de connexion pour luminaires pour usage domestique et analogue - Partie 1:
Exigences générales (CEI 61995-1:2005, modifiée)
Ta slovenski standard je istoveten z: EN 61995-1:2008
ICS:
29.120.20 Spojni elementi Connecting devices
29.140.40 Svetila Luminaires
SIST EN 61995-1:2008 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
EUROPEAN STANDARD
EN 61995-1
NORME EUROPÉENNE
May 2008
EUROPÄISCHE NORM
ICS 29.120.20; 29.140.40
English version
Devices for the connection of luminaires
for household and similar purposes -
Part 1: General requirements
(IEC 61995-1:2005, modified)
Dispositifs de connexion pour luminaires Betriebsmittel für den Anschluss von
pour usage domestique et analogue - Leuchten für Haushalt
Partie 1: Exigences générales und ähnliche Zwecke -
(CEI 61995-1:2005, modifiée) Teil 1: Allgemeine Anforderungen
(IEC 61995-1:2005, modifiziert)
This European Standard was approved by CENELEC on 2008-04-01. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the
Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels
© 2008 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61995-1:2008 E
---------------------- Page: 2 ----------------------
EN 61995-1:2008 – 2 –
Foreword
The text of the International Standard IEC 61995-1:2005, prepared by SC 23B, Plugs,
socket-outlets and switches, of IEC TC 23, Electrical accessories, together with common
modifications prepared by the Technical Committee CENELEC TC 23BX, D.C. plugs and socket
outlets and switches for household and similar fixed electrical installations, was submitted to the
Unique Acceptance Procedure and was approved by CENELEC as EN 61995-1 on 2008-04-01.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2009-04-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2013-04-01
Annexes ZA and ZB have been added by CENELEC.
__________
---------------------- Page: 3 ----------------------
– 3 – EN 61995-1:2008
Endorsement notice
The text of the International Standard IEC 61995-1:2005 was approved by CENELEC as a
European Standard with agreed common modifications as given below.
COMMON MODIFICATIONS
1 Scope
Replace the first three paragraphs by:
This standard applies to devices for the connection of luminaires (DCL) intended for household
and similar purposes, for the electrical connection of fixed luminaires of class I or class II to final
circuits rated at not more than 16 A without providing a mechanical support for the luminaire.
DCLs are intended for use according to their IP rating per EN 60529.
Outlets have an earthing contact and a rated current of 6 A, plugs are rated at 6 A.
The rated voltage is 250 V at 50 Hz.
Replace NOTE 2 and its contents by NOTE 2 Void.
3 Terms and definitions
Add the following new definition:
3.Z1
DCL temporary lampholder
independent lampholder designed in order to be temporarily connected to a DCL outlet, in
compliance with the corresponding standards.
Moreover this lampholder is provided with a DCL rewirable plug (2P + E) to be used for the
connection of a luminaire later
7 Classification
7.3.1.1 Replace the NOTE and its contents by NOTE Void.
9 Checking of dimensions
9.2 Replace the first paragraph by the following new paragraph:
DCL types classified according to 7.1 b) as other types shall comply with the relevant
specification and shall not
- be interchangeable with any socket-outlet systems of IEC 60083 and EN 60309-2,
- create a hazardous situation with DCL types complying with the standard sheets of Part 2 or
any existing DCL or any socket-outlet systems of IEC 60083 and EN 60309-2.
10 Protection against electric shock
10.2.2 Replace NOTE 2 and its contents by NOTE 2 Void.
---------------------- Page: 4 ----------------------
EN 61995-1:2008 – 4 –
11 Provision for earthing
11.4 Add after the first paragraph the following new paragraph:
For DCL with resilient earthing contact where the contact pressure is not dependant on insulating
material, the connection between the earthing contact of the DCL outlet and that of the DCL plug
shall be of low resistance.
Replace the first sentence of the compliance by:
Compliance is checked by the following test after the tests of Clauses 18 and 19.
Add at the end of the second paragraph of the compliance:
and for DCL’s with earthing contacts between the DCL outlet earthing terminal and DCL plug
earthing terminal.
12 Terminal and terminations
12.1 General
Delete in Table 1 the two rows related to signal terminals.
13 Construction of DCL outlets
13.6.2 Add in Table 9, first column, last row:
“and clearances” after “creepage distances”
16 Insulation resistance and electric strength
16.2 Replace the second paragraph by:
The test voltage shall be 2 000 V.
18 Marking and breaking capacity
Replace the tenth paragraph by the following new paragraph:
The tests are carried out at 250 V.
19 Temperature rise
19.3 Replace the second paragraph by the following new paragraph:
For accessories designed and constructed so that the contact pressure in the earthing socket-
contact assemblies is reliant on the insulating material additional separate tests shall be made
passing the current through the earthing contact and the phase or neutral contact whichever is
nearer.
20 Force necessary to insert and withdraw the plug
Replace in the last but one paragraph “4 N” by “10 N”.
Delete the last paragraph.
---------------------- Page: 5 ----------------------
– 5 – EN 61995-1:2008
Bibliography
Add the following notes for the standards indicated:
IEC 60228 NOTE Harmonized as HD 383 S2 (modified).
HD 383 S2 is superseded by EN 60228:2005, which is based on IEC 60228:2004 (not
modified).
IEC 60470 NOTE Harmonized as EN 60470:2000 (not modified).
IEC 60598-1 NOTE Harmonized as EN 60598-1:2004 (modified).
IEC 60670-1 NOTE Harmonized as EN 60670-1:2005 (modified).
IEC 60999-1 NOTE Harmonized as EN 60999-1:2000 (not modified).
IEC 61140 NOTE Harmonized as EN 61140:2001 (not modified).
ISO 2039-2 NOTE Harmonized as EN ISO 2039-2:1999 (not modified).
---------------------- Page: 6 ----------------------
EN 61995-1:2008 – 6 –
Annexes
Add the following new Annexes ZA and ZB:
Annex ZA
(normative)
Special national conditions
Special national condition: National characteristic or practice that cannot be changed even
over a long period, e.g. climatic conditions, electrical earthing conditions.
NOTE If it affects harmonization, it forms part of the European Standard.
For the countries in which the relevant special national conditions apply these provisions are
normative, for other countries they are informative.
Clause Special national condition
1 Belgium, France, Germany, Italy
Only DCL types with a standardised interface according to EN 61995-2 are
used.
7.3.1.1 Denmark
Only DCL plugs for connection of flexible cables are allowed.
9.2 Denmark
For many years Denmark has had a supporting 10 A DCL system on the
market.
Add the following indent after the last indent:
– be interchangeable with or create a hazardous situation with this
special Danish DCL system
10.2.2 Denmark
Due to the lack of an earthing conductor in many existing old buildings
luminaires with DCL plugs requiring earth connection cannot normally be
used.
---------------------- Page: 7 ----------------------
– 7 – EN 61995-1:2008
Annex ZB
(normative)
Normative references to international publications
with their corresponding European publications
The following referenced documents are indispensable for the application of this document. For
dated references, only the edition cited applies. For undated references, the latest edition of the
referenced document (including any amendments) applies.
NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.
Publication Year Title EN/HD Year
1)
IEC 60068-2-32 1975 Environmental testing - EN 60068-2-32 1993
Part 2: Tests - Test Ed: Free fall
IEC 60068-2-75 1997 Environmental testing - EN 60068-2-75 1997
Part 2: Tests - Test Eh: Hammer tests
2) 3)
IEC 60112 - Method for the determination of the proof EN 60112 2003
and the comparative tracking indices of solid
insulating materials
2) 4)
IEC 60227-5 - Polyvinyl chloride insulated cables of rated - -
voltages up to and including 450/750 V -
Part 5: Flexible cables (cords)
IEC 60417 Data- Graphical symbols for use on equipment - -
base
2) 3)
IEC 60529 - Degrees of protection provided EN 60529 1991
by enclosures (IP Code) + corr. May 1993
2) 3)
IEC 60695-2-11 - Fire hazard testing - EN 60695-2-11 2001
Part 2-11: Glowing/hot-wire based test
methods - Glow-wire flammability test method
for end-products
IEC 61032 1997 Protection of persons and equipment by EN 61032 1998
enclosures - Probes for verification
1)
EN 60068-2-32 includes A2:1990 to IEC 60068-2-32.
2)
Undated reference.
3)
Valid edition at date of issue.
4)
HD 21.5:1994 + A1:1999 + A2:2001, which is related to, but not directly equivalent with IEC 60227-5, applies
instead.
---------------------- Page: 8 ----------------------
NORME CEI
INTERNATIONALE IEC
61995-1
INTERNATIONAL
Première édition
STANDARD
First edition
2005-03
Dispositifs de connexion pour luminaires pour
usage domestique et analogue –
Partie 1:
Exigences générales
Devices for the connection of luminaires for
household and similar purposes –
Part 1:
General requirements
IEC 2005 Droits de reproduction réservés Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in any
utilisée sous quelque forme que ce soit et par aucun procédé, form or by any means, electronic or mechanical, including
électronique ou mécanique, y compris la photocopie et les photocopying and microfilm, without permission in writing from
microfilms, sans l'accord écrit de l'éditeur. the publisher.
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
CODE PRIX
Commission Electrotechnique Internationale PRICE CODE XB
International Electrotechnical Commission
Международная Электротехническая Комиссия
Pour prix, voir catalogue en vigueur
For price, see current catalogue
---------------------- Page: 9 ----------------------
61995-1 IEC:2005 – 3 –
CONTENTS
FOREWORD.7
1 Scope .11
2 Normative references .11
3 Terms and definitions .13
4 General requirements .17
5 General notes on tests.17
6 Ratings .19
7 Classification.19
8 Marking .21
9 Checking of dimensions.25
10 Protection against electric shock.27
11 Provision for earthing.31
12 Terminals and terminations.31
13 Construction of DCL outlets .55
14 Construction of DCL Plugs.63
15 Resistance to ageing and to humidity .67
16 Insulation resistance and electric strength.69
17 Operation of earthing contacts .73
18 Making and breaking capacity.73
19 Temperature rise .75
20 Force necessary to insert and withdraw the plug .79
21 Flexible cables and their connection .79
22 Mechanical strength .85
23 Resistance to heat.105
24 Screws, current-carrying parts and connections.109
25 Creepage distances, clearances and distances through sealing compound .113
26 Resistance of insulating material to abnormal heat, to fire and to tracking.117
27 Resistance to rusting .121
28 EMC Requirements.121
Figure 1 – Arrangement for checking damage to conductors .35
Figure 2 – Information for deflection test .53
Figure 3 – Circuit diagram for temperature rise test .77
Figure 4 – Apparatus for testing the flexible cable retention .81
Figure 5 – Sequence of blows for parts A, B, C and D.89
Figure 6 – Arrangement for test on covers or cover-plates .93
Figure 7 – Gauge (thickness: about 2 mm) for the verification of the outline of covers
or cover-plates.97
Figure 8 – Examples of application of the gauge of Figure 7 on covers fixed without
screws on a mounting surface or supporting surface.99
---------------------- Page: 10 ----------------------
61995-1 IEC:2005 – 5 –
Figure 9 – Examples of application of the gauge of Figure 7 in accordance with the
requirements of 22.6.101
Figure 10 – Gauge for verification of grooves, holes and reverse tapers.103
Figure 11 – Sketch showing the direction of application of the gauge of Figure 10.103
Figure 12– Ball pressure test apparatus .107
Table 1 – Connection of copper conductors .33
Table 2– Values for checking damage to conductors .37
Table 3 – Values for pull forces.39
Table 4 – Core composition of conductors .39
Table 5 – Screw torque values .41
Table 6 – Test current for checking screwless terminals .47
Table 7 – Conductors for deflection test .55
Table 8 – Force for deflection test .55
Table 9– Forces to be applied to covers, cover-plates whose fixing is not dependent on
screws.59
Table 10 – Test sequence for temperature rise test .79
Table 11 – Cable dimensions for the flexible cable retention test .83
Table 12 – Schedule of mechanical strength test .85
Table 13 – Height of fall for impact test .87
Table 14 – Creepage distances and clearances.115
---------------------- Page: 11 ----------------------
61995-1 IEC:2005 – 7 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
DEVICES FOR THE CONNECTION OF LUMINAIRES
FOR HOUSEHOLD AND SIMILAR PURPOSES –
Part 1: General requirements
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61995-1 has been prepared by subcommittee 23B: Plugs, socket-
outlets and switches, of IEC technical committee 23: Electrical accessories.
The text of this standard is based on the following documents:
FDIS Report on voting
23B/776/FDIS 23B/782/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
---------------------- Page: 12 ----------------------
61995-1 IEC:2005 – 9 –
IEC 61995 consists of the following parts, under the general title Devices for the connection of
luminaires for household and similar purposes:
Part 1: General requirements
Part 2: Standard sheets
The committee has decided that the contents of this publication will remain unchanged until
the maintenance result date indicated on the IEC web site under "http://webstore.iec.ch" in
the data related to the specific publication. At this date, the publication will be
• reconfirmed;
• withdrawn;
• replaced by a revised edition, or
• amended.
---------------------- Page: 13 ----------------------
61995-1 IEC:2005 – 11 –
DEVICES FOR THE CONNECTION OF LUMINAIRES
FOR HOUSEHOLD AND SIMILAR PURPOSES –
Part 1: General requirements
1 Scope
This part of IEC 61995-1 applies to devices for the connection of luminaires (DCL) intended
for household and similar purposes, for the electrical connection of fixed luminaires to final
circuits rated at not more than 16 A without providing mechanical support for the luminaire.
DCLs are intended for use according to their IP rating per IEC 60529.
Outlets have an earthing contact and a rated current of 6 A, plugs are rated at 6 A, unless
otherwise specified in the relevant part 2.
The rated voltage is 125 V or 250 V at 50/60 Hz.
NOTE 1 This standard does not cover integrated DCL-plugs (under consideration).
This standard can also be applied to types other than those with standardised interface.
NOTE 2 In the following countries only types with a standardised interface according to IEC 61995-2 (under
consideration) are allowed: IT.
DCL plugs and DCL outlets complying with this standard are suitable for use under the
following conditions:
– an ambient temperature not normally exceeding 25 °C, but occasionally reaching 35 °C;
NOTE 3 The effect of the heat generated by the luminaire may affect the ambient temperature local to the
DCL.
– a temperature not exceeding 70 °C at the terminals of the DCL outlet including the effect
of heat generated by the luminaire and the passage of current.
NOTE 4 The requirements and tests of this standard may also be used as a guide when testing DCL's which
have different interface configurations or ratings.
2 Normative references
The following referenced documents are indispensable for the application of this document.
For dated references, only the edition cited applies. For undated references, the latest edition
of the referenced document (including any amendments) applies.
IEC 60068-2-32:1975, Environmental testing – Part 2: Tests – Test Ed: Free fall
IEC 60068-2-75:1997, Environmental testing – Part 2: Tests – Test Eh: Hammer test
IEC 60112, Method for the determination of the proof and the comparative tracking indices of
solid insulating materials
---------------------- Page: 14 ----------------------
61995-1 IEC:2005 – 13 –
IEC 60227-5, Polyvinyl chloride insulated cables of rated voltages up to and including
450/750V – Part 5: Flexible cables (cords)
1)
IEC 60417-DB: , Graphical symbols for use on equipment
IEC 60529, Degrees of protection provided by enclosures
IEC 60695-2-11, Fire hazard testing – Part 2-11: Glowing/hot-wire based test methods –
Glow-wire flammability test method for end-products
IEC 61032:1997, Protection of persons and equipment by enclosures – Probes for verification
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
Where the terms voltage and current are used, they imply r.m.s. values, unless otherwise
specified.
Throughout this standard the word "earthing" is used for "protective earthing".
3.1
device for connecting a luminaire
DCL
system comprising a DCL outlet and a DCL plug providing a fixed luminaire with electrical
connection to and disconnection from a fixed installation
NOTE The designations DCL, DCL outlet or DCL plug, are used when it is necessary to specify particular
requirements and test specifications.
3.2
DCL outlet
device for connecting a luminaire having socket-contacts designed to engage with the pins of
a DCL plug and having terminals for the connection of cable
3.3
DCL plug
device for connecting a luminaire having pins designed to engage with the contacts of a DCL
outlet, also incorporating means for the electrical connection and mechanical retention of
flexible cable
3.4
rewirable DCL plug
DCL plug so constructed that the flexible cable can be replaced
3.5
non-rewirable DCL plug
DCL plug so constructed that it forms a complete unit with the flexible cable after connection
and assembly by the manufacturer of the plug (see also 14.1)
———————
1)
“DB” refers to the IEC on-line database.
---------------------- Page: 15 ----------------------
61995-1 IEC:2005 – 15 –
3.6
moulded-on DCL plug
non-rewirable DCL plug, the manufacture of which is completed by insulating material
moulded around pre-assembled component parts and the terminations of the flexible cable
3.7
rated voltage
voltage assigned to the DCL plug or DCL outlet by the manufacturer
3.8
rated current
current assigned to the DCL plug or DCL outlet by the manufacturer
3.9
mounting box
box in or on a wall or ceiling, etc., for flush or surface application, intended to house a DCL
outlet
3.10
terminal
insulated or non-insulated connecting device intended for reusable electrical connection of the
external conductors
3.11
termination
insulated or non-insulated connecting device intended for non-reusable electrical connection
of the external conductors
3.12
clamping unit
part or parts of a terminal necessary for the mechanical clamping and the electrical
connection of the conductor(s)
3.13
screw-type terminal
terminal for the connection and subsequent disconnection of a conductor or the
interconnection of two or more conductors capable of being dismantled, the connection being
made, directly or indirectly, by means of screws or nuts of any kind
3.14
pillar terminal
terminal with screw clamping in which the conductor is inserted into a hole or cavity, where it
is clamped under the shank of the screw or
...
Questions, Comments and Discussion