SIST-TS CEN/TS 13598-3:2012
(Main)Plastics piping systems for non-pressure underground drainage and sewerage - Unplasticized poly(vinyl chloride)(PVC-U), polypropylene (PP) and polyethylene (PE) - Part 3: Guidance for assessment of conformity
Plastics piping systems for non-pressure underground drainage and sewerage - Unplasticized poly(vinyl chloride)(PVC-U), polypropylene (PP) and polyethylene (PE) - Part 3: Guidance for assessment of conformity
This Technical Specification gives guidance for the assessment of conformity of compounds/formulations, products and assemblies in accordance with Parts 1 and 2 of EN 13598 intended to be included in the manufacturer’s quality plan as part of the quality management system and for the establishment of third-party certification procedures. In conjunction with EN 13598- 1 and -2, this Technical Specification is applicable to ancillary underground drainage fittings including manholes and inspection chambers: - for non-pressure underground drainage and sewerage outside the building structure (application area code "U"), reflected in the marking of products by "U", and - for non-pressure underground drainage and sewerage for both buried in ground within the building structure (application area code "D") and outside the building structure (application area code "U"), reflected in the marking of products by "UD".
Kunststoff-Rohrleitungssysteme für erdverlegte drucklose Abwasserkanäle und -leitungen - Zusatzprodukte einschließlich Kontrollschächte und Einsteigschächte aus weichmacherfreiem Polyvinylchlorid (PVC-U), Polypropylen (PP) und Polyethylen (PE) - Teil 3: Empfehlungen für die Beurteilung der Konformität
EN 13598-3 enthält Empfehlungen für die Beurteilung der Konformität von Form¬massen/Zu-sammensetzungen, Erzeug¬nissen und Bauteilkombinationen entsprechend EN 13598 1:2010 und
EN 13598-2:2009, die als Teil des Qualitäts¬manage¬ment¬systems im Qualitätssicherungsplan des Herstellers und für die Ein¬führung von Verfahren der Drittstellenzertifizierung vorgesehen sind.
ANMERKUNG 1 Es wird empfohlen, dass das Qualitätsmanagementsystem EN ISO 9001 [3] oder mindestens ebenso strengen Anforderungen entspricht.
ANMERKUNG 2 Bei Drittstellenzertifizierung wird empfohlen, dass die Zertifizierungsstelle in Abhängigkeit von der Anwendung nach EN 45011:1998 [1], EN 45012:1998 [2] oder EN ISO/IEC 17021 [5] zugelassen ist.
Dieses Dokument gilt in Zusammenhang mit EN 13598-1:2010 und EN 13598-2:2009 für erdverlegte Zubehörteile für die Entwässerung einschließlich Kontrollschächte und Einsteigschächte:
- für erdverlegte drucklose Abwasserkanäle und -leitungen außerhalb der Gebäudestruktur (Anwen-dungs¬kennzeichen „U“), auf dem Erzeugnis gekennzeichnet durch „U“; und
- für erdverlegte drucklose Abwasserkanäle und -leitungen sowohl erdverlegt innerhalb der Gebäudestruktur (Anwendungskennzeichen „D“) als auch außerhalb der Gebäudestruktur (Anwendungs¬kennzeichen „U“), auf dem Erzeugnis gekennzeichnet durch „UD“.
Systèmes de canalisations en plastique pour les branchements et les collecteurs d'assainissement enterrés sans pression - Poly(chlorure de vinyle) non plastifié (PVC-U), polypropylène (PP) et polyéthylène (PE) - Partie 3: Guide pour l'évaluation de la conformité
L'EN 13598 3 fournit un guide pour l'évaluation de la conformité des compositions/formulations, produits et montages en conformité avec l'EN 13598 1:2010 et l'EN 13598 2:2009, destiné à être inclus dans le plan qualité du fabricant dans le cadre du système de management de la qualité et pour l’établissement de procédures de certification par tierce partie.
NOTE 1 Il est recommandé que le système de management de la qualité soit conforme aux exigences pertinentes de l'EN ISO 9001 [3] ou au moins aussi strict que ces exigences.
NOTE 2 En cas de certification par tierce partie, il est recommandé que l'organisme de certification soit accrédité selon l'EN 45011:1998 [1], l'EN 45012:1998 [2] ou l'EN ISO/CEI 17021 [5], suivant le cas.
Conjointement avec l'EN 13598-1:2010 et l'EN 13598-2:2009, le présent document s'applique aux raccords d'assainissement enterrés auxiliaires incluant des regards et des boîtes d’inspection et de branchement :
- pour les branchements et les collecteurs d'assainissement enterrés sans pression à l'extérieur de la structure du bâtiment (code de zone d’application « U »), repérés au niveau du marquage des produits par « U » et
- pour les branchements et les collecteurs d'assainissement enterrés sans pression à la fois enterrés dans la structure du bâtiment (code de zone d'application « D ») et à l'extérieur de la structure du bâtiment (code de zone d'application « U »), repérés au niveau du marquage des produits par « UD ».
Cevni sistemi iz polimernih materialov za odpadno vodo in kanalizacijo, ki delujejo po težnostnem principu in so položeni v zemljo - Nemehčan polivinilklorid (PVC-U), polipropilen (PP) in polietilen (PE) - 3. del: Navodilo za ugotavljanje skladnosti
Ta tehnična specifikacija vsebuje navodila za ugotavljanje skladnosti spojin/formulacij, izdelkov in sestavov s 1. in 2. delom standarda EN 13598, pri čemer naj bi se te informacije vključile v poslovnik kakovosti proizvajalca kot del sistema vodenja kakovosti in za vzpostavitev postopka certificiranja, ki ga izvajajo tretje osebe. Ta tehnična specifikacija se v povezavi s standardoma EN 13598-1 in EN 13598-2 uporablja za pomožne fitinge za odvodnjavanje, ki so položeni v zemljo, vključno z jaški in revizijskimi komorami: – za sisteme za odvodnjavanje in kanalizacijo, ki delujejo po težnostnem principu in so položeni v zemljo zunaj stavbe (koda območja uporabe »U«), kar je razvidno iz oznak »U« na izdelkih, ter – za sisteme za odvodnjavanje in kanalizacijo, ki delujejo po težnostnem principu in so položeni v zemljo, za vkopane sisteme v stavbi (koda območja uporabe »D«) in zunaj stavbe (koda območja uporabe »U«), kar je razvidno iz oznak »UD« na izdelkih.
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
SIST-TS CEN/TS 13598-3:2012
01-september-2012
&HYQLVLVWHPLL]SROLPHUQLKPDWHULDORY]DRGSDGQRYRGRLQNDQDOL]DFLMRNLGHOXMHMR
SRWHåQRVWQHPSULQFLSXLQVRSRORåHQLY]HPOMR1HPHKþDQSROLYLQLONORULG39&
8SROLSURSLOHQ33LQSROLHWLOHQ3(GHO1DYRGLOR]DXJRWDYOMDQMHVNODGQRVWL
Plastics piping systems for non-pressure underground drainage and sewerage -
Unplasticized poly(vinyl chloride)(PVC-U), polypropylene (PP) and polyethylene (PE) -
Part 3: Guidance for assessment of conformity
Kunststoff-Rohrleitungssysteme für erdverlegte drucklose Abwasserkanäle und -
leitungen - Zusatzprodukte einschließlich Kontrollschächte und Einsteigschächte aus
weichmacherfreiem Polyvinylchlorid (PVC-U), Polypropylen (PP) und Polyethylen (PE) -
Teil 3: Empfehlungen für die Beurteilung der Konformität
Systèmes de canalisations en plastique pour les branchements et les collecteurs
d'assainissement enterrés sans pression - Poly(chlorure de vinyle) non plastifié (PVC-U),
polypropylène (PP) et polyéthylène (PE) - Partie 3: Guide pour l'évaluation de la
conformité
Ta slovenski standard je istoveten z: CEN/TS 13598-3:2012
ICS:
23.040.20 Cevi iz polimernih materialov Plastics pipes
93.030 Zunanji sistemi za odpadno External sewage systems
vodo
SIST-TS CEN/TS 13598-3:2012 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST-TS CEN/TS 13598-3:2012
---------------------- Page: 2 ----------------------
SIST-TS CEN/TS 13598-3:2012
TECHNICAL SPECIFICATION
CEN/TS 13598-3
SPÉCIFICATION TECHNIQUE
TECHNISCHE SPEZIFIKATION
April 2012
ICS 93.030
English Version
Plastics piping systems for non-pressure underground drainage
and sewerage - Unplasticized poly(vinyl chloride)(PVC-U),
polypropylene (PP) and polyethylene (PE) - Part 3: Guidance for
assessment of conformity
Systèmes de canalisations en plastique pour les
Kunststoff-Rohrleitungssysteme für erdverlegte drucklose
branchements et les collecteurs d'assainissement enterrés Abwasserkanäle und -leitungen - Weichmacherfreies
sans pression - Poly(chlorure de vinyle) non plastifié (PVC- Polyvinylchlorid (PVC-U), Polypropylen (PP) und
U), polypropylène (PP) et polyéthylène (PE) - Partie 3: Polyethylen (PE) - Teil 3: Empfehlungen für die Beurteilung
Guide pour l'évaluation de la conformité der Konformität
This Technical Specification (CEN/TS) was approved by CEN on 14 February 2012 for provisional application.
The period of validity of this CEN/TS is limited initially to three years. After two years the members of CEN will be requested to submit their
comments, particularly on the question whether the CEN/TS can be converted into a European Standard.
CEN members are required to announce the existence of this CEN/TS in the same way as for an EN and to make the CEN/TS available
promptly at national level in an appropriate form. It is permissible to keep conflicting national standards in force (in parallel to the CEN/TS)
until the final decision about the possible conversion of the CEN/TS into an EN is reached.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland,
Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2012 CEN All rights of exploitation in any form and by any means reserved Ref. No. CEN/TS 13598-3:2012: E
worldwide for CEN national Members.
---------------------- Page: 3 ----------------------
SIST-TS CEN/TS 13598-3:2012
CEN/TS 13598-3:2012 (E)
Contents Page
Foreword .3
Introduction .4
1 Scope .5
2 Normative references .5
3 Terms and definitions .5
4 Abbreviated terms .8
5 General .9
6 Testing and inspection .9
6.1 Material specification of PVC-U .9
6.2 Material specification of PP . 10
6.3 Material specification of PE . 11
6.4 Grouping . 11
6.4.1 General . 11
6.4.2 Size groups . 11
6.4.3 Fitting groups . 12
6.5 Type testing (TT) . 12
6.6 Batch release tests (BRTs) . 15
6.7 Process verification tests (PVTs) . 16
6.8 Audit tests (ATs) . 18
6.9 Indirect tests (ITs) . 21
6.10 Test records . 21
Annex A (informative) Summary of EN 13598-1 test regime . 22
Annex B (informative) Summary of EN 13598-2 test regime . 23
Bibliography . 24
2
---------------------- Page: 4 ----------------------
SIST-TS CEN/TS 13598-3:2012
CEN/TS 13598-3:2012 (E)
Foreword
This document (CEN/TS 13598-3:2012) has been prepared by Technical Committee CEN/TC 155 “Plastics
piping systems and ducting systems”, the secretariat of which is held by NEN.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights.
EN 13598, Plastics piping systems for non-pressure underground drainage and sewerage Unplasticized
poly(vinyl chloride)(PVC-U), polypropylene (PP) and polyethylene (PE) is composed of the three following
parts:
Part 1: Specifications for ancillary fittings including shallow inspection chambers;
Part 2: Specifications for manholes and inspection chambers in traffic areas and deep underground
installations;
Part 3: Guidance for assessment of conformity (CEN/TS) (the present document).
According to the CEN/CENELEC Internal Regulations, the national standards organisations of the following
countries are bound to announce this Technical Specification: Austria, Belgium, Bulgaria, Croatia, Cyprus,
Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
Spain, Sweden, Switzerland, Turkey and the United Kingdom.
3
---------------------- Page: 5 ----------------------
SIST-TS CEN/TS 13598-3:2012
CEN/TS 13598-3:2012 (E)
Introduction
Figures 1 and 2 are intended to provide general information on the concept of testing and organisation of
those tests used for the purpose of the assessment of conformity. For each type of tests (i.e. type testing (TT),
batch release test (BRT), process verification test (PVT) and audit test (AT), this document details the
applicable characteristics to be assessed and the frequency and sampling of testing.
A typical scheme for the assessment of conformity of compounds, products and assemblies by manufacturers
is given in Figure 1.
Figure 1 — Typical scheme for the assessment of conformity by a manufacturer
A typical scheme for the assessment of conformity of compounds, formulations, pipes, fittings, or assemblies
by manufacturers, is given in Figure 2.
Figure 2 — Typical scheme for the assessment of conformity by a manufacturer
4
---------------------- Page: 6 ----------------------
SIST-TS CEN/TS 13598-3:2012
CEN/TS 13598-3:2012 (E)
1 Scope
This Technical Specification gives guidance for the assessment of conformity of compounds/formulations,
products and assemblies in accordance with Parts 1 and 2 of EN 13598 intended to be included in the
manufacturer’s quality plan as part of the quality management system and for the establishment of third-party
certification procedures.
NOTE In order to help the reader, a basic test matrix is given in Annexes A and B.
In conjunction with EN 13598- 1 and -2, this Technical Specification is applicable to ancillary underground
drainage fittings including manholes and inspection chambers:
for non-pressure underground drainage and sewerage outside the building structure (application area
code "U"), reflected in the marking of products by "U", and
for non-pressure underground drainage and sewerage for both buried in ground within the building
structure (application area code "D") and outside the building structure (application area code "U"),
reflected in the marking of products by "UD".
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated references,
the latest edition of the referenced document (including any amendments) applies.
EN 1401-1:2009, Plastics piping systems for non-pressure underground drainage and sewerage —
Unplasticized poly(vinyl chloride) (PVC-U) — Part 1: Specifications for pipes, fittings and the system
EN 13598-1:2010, Plastics piping systems for non-pressure underground drainage and sewerage —
Unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) — Part 1: Specifications
for ancillary fittings including shallow inspection chambers
EN 13598-2:2009, Plastics piping systems for non-pressure underground drainage and sewerage —
Unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) — Part 2: Specifications
for manholes and inspection chambers in traffic areas and deep underground installations
ISO 3951-1, Sampling procedures for inspections by variables ― Part 1: Specification for single sampling
plans indexed by acceptance quality limit (AQL) for lot-by-lot inspection for a single quality characteristic and a
single AQL
3 Terms and definitions
For the purposes of this document, the following terms and definitions given in EN 13598-1:2010 and
EN 13598-2:2009 and the following apply.
3.1
certification body
impartial body, governmental or non-governmental, possessing the necessary competence and responsibility
to carry out certification of conformity according to given rules of procedure and management
Note 1 to entry: A certification body is preferably compliant with EN ISO/IEC 17021 [4], 3.2.
3.2
inspection body
body that performs inspection
Note 1 to entry: A body can be an organisation, or part of an organisation.
[SOURCE: EN ISO/IEC 17020:2004 [5], 2.2]
5
---------------------- Page: 7 ----------------------
SIST-TS CEN/TS 13598-3:2012
CEN/TS 13598-3:2012 (E)
Note 2 to entry: A inspection body is preferably compliant with EN ISO/IEC 17020:2004 [5], 3.3.
3.3
testing laboratory
laboratory which measures, tests, calibrates or otherwise determines the characteristics of the performance of
materials and products
Note 1 to entry: In the context of this part of EN 13598, the compounds / formulations and products can be subjected
to type testing, batch release testing, process verification testing, audit testing and/or witness testing, as applicable.
Note 2 to entry: A testing laboratory is preferably compliant with EN ISO/IEC 17025 [6].
3.4
quality management system
management system to direct and control an organisation with regard to quality
[SOURCE: EN ISO 9000:2005 [7], 3.2.3]
Note 1 to entry: An example of a quality management system is given in EN ISO 9001 [1].
3.5
quality plan
document setting out the specific quality practices, resources and sequence of activities relevant to a
particular product or range of products
3.6
type testing
TT
testing performed to verify that the material, product, joint or assembly is capable of conforming to the
requirements given in the relevant standard
Note 1 to entry: The type test results remain valid until there is a change in the material or product or assembly
provided that the process verification tests are done regularly.
3.7
batch release test
BRT
test performed by or on behalf of the manufacturer on a product batch, which has to be satisfactorily
completed before the batch can be released
3.8
process verification test
PVT
test performed by or on behalf of the manufacturer on products and assemblies at specific intervals to confirm
that type test originally performed on these products and assemblies continue to be valid and that the process
continues to be capable of producing products which conform to the requirements given in the relevant
standard
Note 1 to entry: Such tests are not required to release batches of products and are carried out as a measure of
process control.
3.9
audit test
AT
test performed by a test laboratory on behalf of an inspection body or certification body to confirm that the
compound, product, and assembly continues to conform to the requirements given in the relevant standard
and to provide information to assess the effectiveness of the quality management system
6
---------------------- Page: 8 ----------------------
SIST-TS CEN/TS 13598-3:2012
CEN/TS 13598-3:2012 (E)
3.10
indirect test
IT
test performed by or on behalf of the manufacturer, different from that specified test for that particular
characteristic, having previously verified its correlation with the test specified
3.11
witness test
WT
testing accepted by an inspection or a certification body for type testing and/or audit testing, which is carried
out by or on behalf of the manufacturer and supervised by a representative of the inspection or certification
body, qualified in testing
3.12
material
compounds/formulations grouped by families, expressed by generic names, e.g. polypropylene, stainless
steel, brass or EPDM
Note 1 to entry: Definition from European Commission, Directorate-General for Enterprise and Industry, Sub-group on
Product Testing Procedures (EC, DG ENT and IND, SG PTP).
3.13
compound/formulation
clearly defined homogenous mixture of base polymer with additives, i.e. anti-oxidants, pigments, stabilisers
and others, at a dosage level necessary for the processing and the intended use of the final product
3.14
material batch
clearly identified quantity of a given homogeneous compound manufactured under uniform conditions and
defined and identified by the compound/formulation manufacturer
3.15
product
underground ancillary fittings and components intended to provide a means of access to the drainage system
of a clearly identified type as specified in Parts 1 and 2 intended to be a part of a the drainage system
3.16
product batch
clearly identified collection of products, manufactured consecutively or continuously under the same
conditions, using the same compound/ formulation conforming to the same specification
Note 1 to entry: The product batch is defined and identified by the product manufacturer.
3.17
lot
clearly identifiable sub-division of a batch for inspection purposes
3.18
sample
one or more products drawn from the same production batch or lot, selected at random without regard to their
quality
Note 1 to entry: The number of products in the sample is the sample size.
3.19
group
collection of similar products from which samples are selected for testing purposes
7
---------------------- Page: 9 ----------------------
SIST-TS CEN/TS 13598-3:2012
CEN/TS 13598-3:2012 (E)
3.20
component
product manufactured out of a specific compound/formulation, brought to the market as part of another
product or as a spare part
3.21
joint
connection between two products
3.22
assembled component
assembled final product using two or more single parts
3.23
thermoplastics fabricated fitting
fitting produced from pipe and/or from injection-moulded fittings by thermoforming, solvent-cementing or
welding
3.24
sampling plan
specification of the type of sampling to be used combined with the operational specification of the entities or
increments to be taken, the samples to be constituted and the measurements or tests to be made
EXAMPLE A specific plan which indicates the number of units of products or assemblies to be inspected.
3.25
product type
generic description of a product
EXAMPLE A pipe or fitting or their main parts, of the same design, from a particular compound.
3.26
base type
base of a particular design and which can have different diameter and riser connections
3.27
cavity
(moulding) space within a mould to be filled to form the moulded product
EXAMPLE That part of the injection mould which gives the form to the injection moulded product.
4 Abbreviated terms
To avoid misunderstanding, the abbreviations in this Clause are defined as being the same in each language.
For the same reason, the terms are given in the three languages, English, French and German.
EXAMPLE In the French language, the abbreviation for the French equivalent of "acceptable quality level" (AQL) is
NQA; however for the purposes of this part of EN 13598 (CEN/TS 13598-3), the abbreviation of the English term (AQL) is
adopted.
8
---------------------- Page: 10 ----------------------
SIST-TS CEN/TS 13598-3:2012
CEN/TS 13598-3:2012 (E)
EN FR DE
AQL acceptance quality limit niveau de qualité acceptable annehmbare Qualitätsgrenzlage
AT audit test essai d’audit Überwachungsprüfung
BRT batch release test essai de libération de campagne de fabrication Freigabeprüfung einer Charge
IT indirect test essai indirect indirekte Prüfung
PVT process verification test essai de vérification du procédé de fabrication Prozessüberprüfung
TT type test essai de type Typprüfung
WT witness testing essai témoin Prüfung unter Aufsicht
5 General
5.1 Materials, compounds/formulation, products, and assemblies shall conform to the requirements given in
EN 13598-1 and -2.
5.2 Products shall be produced by the manufacturer under a quality management system which includes a
quality plan (including specifications on joints and assemblies).
It is recommended that the quality management system conforms to or is no less stringent than the relevant
requirements to EN ISO 9001 [1].
6 Testing and inspection
6.1 Material specification of PVC-U
For the purposes of this Document, the material specification consists of a formulation which defines types of
PVC and additives and their dosage levels.
The dosage level of ingredients of a material shall not exceed the tolerance bands given in Table 1. If any
level exceeds the dosage band or if a type is changed, this variation in formulation constitutes a change in
material.
The manufacturers own rework material of known compound from his own production shall be allowed without
limitation.
The use of external reformulated, reprocessable and/or recyclable material with agreed specification shall be
considered as a change in formulation when the change in addition exceeds the tolerance bands given in
Table 2.
The values of the parts X added to 100 parts by mass of PVC shall be specified by the manufacturer in his
quality plan.
9
---------------------- Page: 11 ----------------------
SIST-TS CEN/TS 13598-3:2012
CEN/TS 13598-3:2012 (E)
Table 1 ― Formulation specification
Ingredients Type Band
PVC resin Nominal K value: as specified ± 3 units
Type and content of stabiliser or 1) Pb X : ± 25 %
1
master batch 2) Ca-Zn
3) Sn
4) Ca-Sn
5) others
Lubricants All X : ± 50 % for X ≤ 0,2
2 2
X : ± 0,1 parts for X > 0,2
2 2
Fillers CaC0 X : ± 3 parts
1) 3 3
2) others X : ± 25 %
4.
Impact modifiers All X : ± 1 part
5
Flow agents All X : ± 25 % for X ≤ 2
6 6
X : ± 0,5 parts for X > 2
6 6
Pigments No requirement
X : ± 25 %
Others To be separately specified by the
7
manufacturer
Table 2 ― Limits of addition of PVC reprocessable and recycling material
Ingredients Type Band
a
b
External reprocessable With an agreed specification
≤ X
8
and recyclable material
a
The specifications shall be declared by the manufacturer to the certification body.
b
See specifications in A.3 of EN 1401-1:2009.
6.2 Material specification of PP
For the purposes of this document, the material specification consists of a compound comprising a PP
compound with specific trade name and additives with known dosage level.
The manufacturers own rework material of known compound from his own production shall be allowed without
limitation.
Reformulated material must meet the band requirements of Annex A of EN 13598-1:2010 and Annex A or B of
EN 13598-2:2009.
The use of external reformulated, reprocessable and/or recyclable material with agreed specification shall be
considered as a change in formulation when the change in addition exceeds the tolerance bands given in
Table 3.
10
---------------------- Page: 12 ----------------------
SIST-TS CEN/TS 13598-3:2012
CEN/TS 13598-3:2012 (E)
Table 3 ― Limits of addition of PP reprocessable and recycling material
Ingredients Type Band
a
External reprocessable With an agreed specification ≤ X
1
and recyclable material
a
The specification shall be declared by the manufacturer to the certification body.
6.3 Material specification of PE
For the purposes of this document, the material specification consists of a compound comprising a PE
compound with specific trade name and additives with known dosage level.
The manufacturers own rework material of known compound from his own production shall be allowed without
limitation.
Reformulated material must meet the band requirements of Annex A of EN 13598-1:2010 and Annex A or B of
EN 13598-2:2009.
The use of external reformulated, reprocessable and/or recyclable material with agreed specification shall be
considered as a change in formulation when the change in addition exceeds the tolerance bands given in
Table 4.
Table 4 ― Limits of addition of PE reprocessable and recycling material
Ingredients Type Band
a
External reprocessable With an agreed specification ≤ X1
and recyclable material
a
The specification shall be declared by the manufacturer to the certification body.
6.4 Grouping
6.4.1 General
For the purposes of this document, the following groups apply.
6.4.2 Size groups
4 size groups are defined for ancillary products, inspection chambers and manholes, as given in Table 5.
For testing purposes, one individual nominal diameter, d , as defined in Parts 1 and 2 shall be selected from
n
each group.
Table 5 — Size groups
Size group Nominal outside diameter, Nominal diameter DN/ID
DN/OD
mm
mm
≤ 180
1
≤ 200
2 >200 and ≤ 500
> 180 and ≤ 450
3
>500 and ≤ 1 200
> 450 and ≤ 1 000
4 > 1 200
>1 000
NOTE For Inspection chamber and manholes size relates to the riser diameter. Mechanical saddles are sized by the
diameter of the main pipe that they are intended to joint to. Other ancillary products are sized by their outlet diameter.
11
---------------------- Page: 13 ----------------------
SIST-TS CEN/TS 13598-3:2012
CEN/TS 13598-3:2012 (E)
6.4.3 Fitting groups
6 groups of fittings are defined, as given in Table 6.
For testing purposes, one individual fitting shall be selected from each group.
Each group shall consist of a range of products of the same material and design.
Table 6 — Fitting groups
Fitting group Type of fitting
1 Sealed access fittings
2 Rodding point tees
3 Rodding point covers
4 Mechanical Saddles
5 Inspection Chambers
6 Manholes
6.5 Type testing (TT)
Relevant type tests shall be carried out whenever there is a change in design, in compound /formulation
and/or in the production method, other than routine in-process adjustments, and/or whenever there is an
extension of the product range.
Type tests shall demonstrate that the products conform to all requirements for the characteristics given in
Tables 7 and 8.
Key (to Tables 7 and 8)
N new system
D change in design
M change of compound-formulation
P change of production method
E extension of the product range (except the products already covered by the scheme of sampling
procedure)
+ test to be carried out
NOTE The manufacturer should submit intended marking details of the product to the certification body prior to
approval.
12
---------------------- Page: 14 ----------------------
SIST-TS CEN/TS 13598-3:2012
CEN/TS 13598-3:2012 (E)
Table 7 — Characteristics of EN 13598-1:2010 products that require type testing (TT)
Characteristic Reference to Conditions requiring Sampling procedure
clause or test
subclause of a
N D M P E Manufacturer Certification body
EN 13598-
1:2010
Material 4.1 + + Once per Once per
compound/formulation compound/formulation
Appearance 5.1 + + + Once per fitting Once per fitting group
Colour 5.3 + + + Once per fitting Once per fitting group
Geometrical characteristics 6.2 and 6.3 + + + + + Once per fitting Once per size group
and per fitting group
Effect of heating 8 + + + + Once per fitting Once per fitting group
PVC-U injection moulded
+ Once per size group Once per
products
per fittings group compound/formulation
Mechanical characteristics inspection chamber shallow
Stiffness of riser shaft 9 + + + + + Once per riser Once per size group
Vacuum requirement of base 9 + + + + + Once per fitting Once per size group
Resistance of riser / base to 9 + + + + + Once per fitting Once per size group
vertical loading
Mechanical characteristics mechanical saddles
Resistance to vertical load 9 + + + + + Once per fitting Once size group of
branch inlet per joint
c
design
Mechanical strength of 9 + + + + + Once per fitting Once per size group
c
saddle per joint design
(saddle to pipe)
Mechanical characteristics rodding point covers
Resistance to vertical 9 + + + + + Once per fitting Once per size group
loading
b
Mechanical characteristics fabricated fittings
Mechanical strength and 9 + + + + Once per fitting Once per size group
flexibility per fitting group
Leaktightness of fabricated 9 + + + + Once per fitting Once per size group
fittings per fittings group
Performance characteristics
Tightness of elastomeric 10 + + + + Once per fitting per Once per size group
c c
sealing ring joints to pipes joint design per joint design
Elevated temperature 10 + + + + Once per fitting per Once per size group
c
resistance of UD fittings joint design per fittings group
Tightness of fittings other 10 + + + + Once per fitting per Once per size group
c
than shallow inspection joint design per fittings group per
c
chambers joint design
Watertightness of shallow 10 + + + + Once per fitting per Once per size group
c
inspection chambers joint design of main channel per
c
joint design
Shear resistance of joints to 10 + + + + Once per fitting per Once per size group
c c
rigid pipes joint design per joint design
a
Recommended sampling procedure for a testing laboratory working on behalf of a certification body. Testing undertaken in a
manufacturer laboratory shall be taken into account, provided prior acceptance by the certification body.
13
---------------------- Page: 15 ----------------------
SIST-TS CEN/TS 13598-3:2012
CEN/TS 13598-3:2012 (E)
b
Only for fabricated fittings made fr
...
Questions, Comments and Discussion