Abstract

This part of IEC/IEEE 62395 provides detailed recommendations for the system design, installation, maintenance and repair of electrical resistance trace heating systems in industrial and commercial applications. This document does not include or provide for any applications in potentially explosive atmospheres.
This document pertains to trace heating systems that can comprise either factory fabricated or field-assembled (work-site) units, and which can be series or parallel trace heaters, or surface heaters (heater pads or heater panels) that have been assembled and/or terminated in accordance with the manufacturer's instructions.
The products covered by this document are intended to be installed by persons who are suitably trained in the techniques required and that only trained personnel carry out especially critical work, such as the installation of connections and terminations. Installations are intended to be carried out under the supervision of a qualified person who has undergone supplementary training in electric trace heating systems.
This document does not cover induction, impedance or skin effect heating.
Trace heating systems and surface heating systems can be grouped into different types of installations. These are characterized by different requirements for testing and are usually certified for a specific type of installation or application. Typical applications for the different types of installation are shown in Table 1.

Status
Published
Public Enquiry End Date
31-Mar-2026
Publication Date
07-Jul-2026
Technical Committee
I09 - Imaginarni 09
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
07-Jul-2026
Due Date
11-Sep-2026
Completion Date
08-Jul-2026

Buy Documents

Standard

SIST EN IEC 62395-2:2026 - BARVE

English language (91 pages)
Preview
Preview
e-Library read for
×1 day

SIST EN IEC 62395-2:2026 is the CENELEC European Standard for electrical resistance trace heating systems for industrial and commercial applications, based on the joint IEC/IEEE document prepared by the International Electrotechnical Commission (IEC) and the Institute of Electrical and Electronics Engineers (IEEE). It is an application guide for system design, installation, maintenance and repair, and it is meant to be used with EN IEC/IEEE 62395-1 for the general and testing requirements. The scope covers trace heating for piping, vessels, roofs and concrete slab applications, while excluding potentially explosive atmospheres.

What does SIST EN IEC 62395-2:2026 specify?

SIST EN IEC 62395-2:2026 gives detailed recommendations for selecting, designing, installing, maintaining and repairing electrical resistance trace heating systems in industrial and commercial use. It is organized as a practical guide, moving from general vessel and piping applications to specific application chapters for roofs, rails, snow melting, floor warming, frost heave prevention and underground thermal energy storage.

The scope covers factory-fabricated and field-assembled systems, including series and parallel trace heaters and surface heaters such as heater pads or heater panels when assembled and terminated to the manufacturer's instructions. It does not cover induction, impedance or skin effect heating.

Table 1 classifies the main installation types and why that matters in practice:

TypeTypical applicationsMain point for selection
AInsulated surfaces such as hot water lines, freeze protection, grease lines, fuel oil lines, pre-insulated pipe and sprinkler systemsFocus on dielectric, thermal, mechanical and moisture-exclusion performance
BOutdoor exposed areas such as roof deicing, gutter and downspout deicing, catch basins, drains and rail heatingFocus on UV, moisture, condensation, cutting and abrasion resistance
CEmbedded installations such as snow melting, frost heave protection, floor warming and embedded energy storage systemsFocus on embedded use, cutting and crushing resistance
DInstallations with trace heater inside conduit or piping, including potable water lines and enclosed drains and culvertsFocus on pull strength and moisture resistance in a conduit or pipe

Clause 1 also states that installation should be done by suitably trained people, with especially critical work such as connections and terminations carried out by trained personnel under the supervision of a qualified person with supplementary trace heating training. In practice, this means the standard is aimed at people who must specify, install and service systems correctly, not at untrained users.

What are the key requirements of SIST EN IEC 62395-2:2026?

SIST EN IEC 62395-2:2026 is built around good design practice, correct installation and verifiable maintenance. The most important points are the way it links thermal design, electrical protection, controls and site work so the finished system is safe and fit for the application.

1) Design starts with the application and the environment

Clause 4 begins with surface heating of vessels and piping systems and requires the designer to consider environmental conditions, electrical system design, control and monitoring, trace heating system design and documented design information. The practical point is that heater selection is not done in isolation - the pipe, vessel, insulation, weather exposure and operating temperature all affect the result.

2) Thermal design is based on heat loss and heat-up behavior

Clause 4.3 covers thermal insulation, heat-loss determination, safety factor, heat-up considerations, trace heater selection and theoretical sheath temperature calculations for metallic and non-metallic pipe applications. It also addresses start-up at low ambient temperatures, long trace heater circuits and the chimney effect. In practice, this clause tells the designer to calculate the heating duty, check the temperature limits of the heater and the workpiece, and document the assumptions used.

3) Electrical design must protect every branch circuit

Clause 4.4 requires the electrical system to follow applicable electrical codes and to provide branch circuit protection that can interrupt both high-impedance earth faults and short-circuit faults. It also notes preferred earthing systems and the need for permanent tagging and identification. That matters because trace heating can fail safely only if the protective device, supply and identification scheme are matched to the circuit.

4) Control and monitoring are part of the design, not an afterthought

Clause 4.5 covers mechanical and electronic temperature controllers, controller and sensor location, alarms, integrated control, flow pattern analysis, dead-leg control and monitoring for fire sprinkler systems. The practical message is to place sensors where they reflect the real process condition, and to add alarms where continued operation or fast response matters.

5) Special applications need application-specific design rules

Clause 4.6 gives extra guidance for freeze protection systems, sprinkler systems, hot water services and tempered water, safety shower design requirements and specialty lines. For sprinkler systems and safety showers, the document adds design details that affect insulation layout, alarm strategy and system arrangement. In practice, these are the places where a generic pipe-heating design is not enough.

6) Installation, inspection and commissioning are tightly linked

Clauses 4.7 to 4.9 cover personnel aspects, preparatory work, pre-installation insulation resistance testing, installation of trace heaters and controls, installation of thermal insulation, power connection, commissioning, maintenance and repair. Annex A gives pre-installation checks, Annex B gives a commissioning record and Annex C gives a maintenance schedule and log record. The main practical point is that the system should be checked, recorded and tested before it is buried, insulated or put into service.

7) Each application chapter adds its own operating details

Clauses 5 to 10 apply the same structure to roof and gutter deicing, rail heating, snow melting, floor warming, frost heave prevention and underground thermal energy storage systems. Each chapter adds the control method, installation method and maintenance issues specific to that use. That helps a buyer or engineer compare whether a proposed heater is intended for an exposed roof, an embedded slab or a rail component.

What terms does SIST EN IEC 62395-2:2026 define?

SIST EN IEC 62395-2:2026 uses the terms and definitions from IEC/IEEE 62395-1. The following terms are the ones most likely to matter when reading this part.

  • Trace heater - the heating element installed along or within the workpiece to supply heat where the application needs it.
  • Surface heater - a heater pad or heater panel assembled and/or terminated according to the manufacturer's instructions for use on a surface.
  • Control and monitoring system - the controller, sensor and alarm arrangement used to start, limit and supervise the heating circuit.
  • Earth-fault protection - the protective function that detects and interrupts or alarms on high-impedance earth faults so the circuit does not continue unchecked.
  • Frost heave - floor damage caused when ice builds up in the substrate below a floor and lifts the slab.
  • Dead-leg - a low-flow or no-flow section of piping that needs special control because it can cool differently from the main line.
  • Tempered water - water for eyewash or safety shower use where temperature control and alarmed supervision are important.

Who uses SIST EN IEC 62395-2:2026?

SIST EN IEC 62395-2:2026 is used by engineers, installers, maintenance teams, suppliers and buyers who need to specify or assess trace heating systems for industrial and commercial sites. It is especially relevant to people working on piping and vessels, roof and gutter deicing, rail infrastructure, snow melting slabs, comfort floor warming, frost heave prevention and underground thermal energy storage.

In practice, the document supports design review, heater selection, control strategy, installation supervision, commissioning checks, maintenance planning and repair decisions. Quality managers and buyers can also use it to check whether a proposed system is intended for the right application type and whether the installation and service plan matches the application.

What changed in SIST EN IEC 62395-2:2026 from the previous edition?

SIST EN IEC 62395-2:2026 supersedes EN 62395-2:2013 and all of its amendments and corrigenda. It is described as a technical revision.

The significant technical changes stated for this edition are:

  • the design guidance for trace heating on sprinkler systems has been expanded
  • a figure has been added to show how to avoid unwanted shadowing of spray patterns from insulated sprigs close to sprinkler heads
  • specific design guidance has been added for emergency eyewash units and safety showers

Which standards are used with SIST EN IEC 62395-2:2026?

SIST EN IEC 62395-2:2026 is intended to be read with EN IEC/IEEE 62395-1, which provides the general and testing requirements for electrical resistance trace heating systems. Annex ZA names IEC/IEEE 62395-1:2024 as the normative reference and its European adoption as EN IEC/IEEE 62395-1:2026.

The document also points readers to related trace-heating standards for explosive atmospheres:

  • IEC/IEEE 60079-30-1 - electrical resistance trace heating, general and testing requirements
  • IEC/IEEE 60079-30-2 - application guide for design, installation and maintenance

It also cites IEC 60050 for terminology and the ASHRAE Application Handbook in the bibliography.

What does the SIST EN IEC 62395-2:2026 document contain?

SIST EN IEC 62395-2:2026 contains design guidance, installation methods, maintenance advice and repair guidance across a wide range of trace heating applications. Clause 4 covers vessels and piping, clause 5 roof and gutter deicing, clause 6 rail heating, clause 7 snow melting, clause 8 floor warming, clause 9 frost heave prevention and clause 10 underground thermal energy storage.

The document also includes calculation methods for heat loss, heat-up behavior and snow-melting power balance, plus figures showing typical insulation, heater layouts, rail components, snow-melting layouts and below-floor systems. Tables classify application types and give guidance on monitoring and control, hot water and tempered water, insulation resistance and typical snow melting heat loads.

Annex A provides pre-installation checks, Annex B provides a commissioning record and Annex C provides a maintenance schedule and log record. These annexes are practical tools for site teams because they help document checks, testing and ongoing condition monitoring.

Relations

Effective Date
01-Sep-2026
Effective Date
07-Jul-2026
Effective Date
03-Feb-2026
Effective Date
01-Dec-2026

Buy Documents

Standard

SIST EN IEC 62395-2:2026 - BARVE

English language (91 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

DVS-ZERT GmbH

German welding certification society.

DAKKS Germany Verified

CARES (UK Certification Authority for Reinforcing Steels)

UK certification for reinforcing steels and construction.

UKAS United Kingdom Verified

EWF/IIW (European/International Welding Federation)

International welding personnel certification.

BELAC Belgium Verified

Sponsored listings

Frequently Asked Questions

SIST EN IEC 62395-2:2026 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Electrical resistance trace heating systems for industrial and commercial applications - Part 2: Application guide for system design, installation and maintenance (IEC/IEEE 62395-2:2024)". This standard covers: This part of IEC/IEEE 62395 provides detailed recommendations for the system design, installation, maintenance and repair of electrical resistance trace heating systems in industrial and commercial applications. This document does not include or provide for any applications in potentially explosive atmospheres. This document pertains to trace heating systems that can comprise either factory fabricated or field-assembled (work-site) units, and which can be series or parallel trace heaters, or surface heaters (heater pads or heater panels) that have been assembled and/or terminated in accordance with the manufacturer's instructions. The products covered by this document are intended to be installed by persons who are suitably trained in the techniques required and that only trained personnel carry out especially critical work, such as the installation of connections and terminations. Installations are intended to be carried out under the supervision of a qualified person who has undergone supplementary training in electric trace heating systems. This document does not cover induction, impedance or skin effect heating. Trace heating systems and surface heating systems can be grouped into different types of installations. These are characterized by different requirements for testing and are usually certified for a specific type of installation or application. Typical applications for the different types of installation are shown in Table 1.

This part of IEC/IEEE 62395 provides detailed recommendations for the system design, installation, maintenance and repair of electrical resistance trace heating systems in industrial and commercial applications. This document does not include or provide for any applications in potentially explosive atmospheres. This document pertains to trace heating systems that can comprise either factory fabricated or field-assembled (work-site) units, and which can be series or parallel trace heaters, or surface heaters (heater pads or heater panels) that have been assembled and/or terminated in accordance with the manufacturer's instructions. The products covered by this document are intended to be installed by persons who are suitably trained in the techniques required and that only trained personnel carry out especially critical work, such as the installation of connections and terminations. Installations are intended to be carried out under the supervision of a qualified person who has undergone supplementary training in electric trace heating systems. This document does not cover induction, impedance or skin effect heating. Trace heating systems and surface heating systems can be grouped into different types of installations. These are characterized by different requirements for testing and are usually certified for a specific type of installation or application. Typical applications for the different types of installation are shown in Table 1.

SIST EN IEC 62395-2:2026 is classified under the following ICS (International Classification for Standards) categories: 25.180.10 - Electric furnaces. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN IEC 62395-2:2026 has the following relationships with other standards: It is inter standard links to SIST EN 62395-2:2014, SIST EN 60519-10:2013, SIST EN IEC 62395-1:2026, SIST EN IEC/IEEE 62395-2:2026/AC:2026. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

SIST EN IEC 62395-2:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Surface heating of vessels and piping systems
  • 4.1 Application description
  • 4.2 Design information – General
  • 4.3 Thermal system design
  • 1 Metal jacket 5 Closure band
  • 2 Insulation 6 Insulated strap
  • 3 Metal jacket insulated pipe 7 Movement
  • 4 Mastic sealer 8 Pipe
  • 1 Pipe 6 Pipe temperature
  • 2 Inner insulation layer 7 Interface temperature
  • 3 Heat tracer 8 Outer insulation surface temperature
  • 4 Outer insulation layer 9 Ambient temperature
  • 5 Metal foil (aluminium)
  • 4.4 Electrical design
  • 4.5 Control and monitoring system design
  • 1 Circuit No. 1 5 Temperature sensor
  • 2 Circuit No. 2 6 Pump
  • 3 Circuit No. 3 7 Heated tank
  • 4 Cold end termination 8 Hot end termination
  • 1 Circuit No. 1 4 Hot end termination
  • 2 Circuit No. 2 5 Cold end termination
  • 3 Circuit No. 3 6 Temperature sensor
  • 4.6 Special design considerations
  • 2 Insulation is flush with top of reducing fitting
  • 1 Containment (dead air space) 5 Rigid foam insulation
  • 2 Weather barrier 6 Second trace heater (optional)
  • 3 Temperature sensor 7 Channel
  • 4 Containment piping 8 Trace heater
  • 1 Rigid foam insulation 5 Trace heater at 6 o'clock
  • 2 Outer jacket 6 Second trace heater at 8 o'clock
  • 3 Channel 7 Temperature sensor
  • 4 Temperature sensor 8 First trace heater at 4 o'clock
  • 4.7 Installation
  • 4.8 Maintenance
  • 4.9 Repair
  • 5 Roof and gutter deicing
  • 5.1 Application description
  • 1 Snow 3 Layered ice dam
  • 2 Water build-up 4 Soffit
  • 5.2 Design information – General
  • 1 Downspout 4 Gravel
  • 2 Siding 5 Trace heater loop
  • 3 Sand 6 Earth
  • 5.3 Thermal design
  • 5.4 Electrical design
  • 5.5 Control and monitoring system design
  • 5.6 Special design considerations
  • 5.7 Installation
  • 1 Snow guard 3 Junction box
  • 2 Trace heater 4 Low point drain or drip loop
  • 1 Gutter 3 Soffit
  • 2 Aluminium tape or clip 4 Trace heater
  • 1 Clip 6 Trace heater in bottom of gutter
  • 2 Sealant 7 Strapping
  • 3 Trace heater 8 Peg under tile
  • 4 Roof 9 Clip adhered to flat roof surface and attached to any grid covering gutter
  • 5 Gutter
  • 1 Power connection and end seal terminate in junction box 3 Trace heater
  • 2 Drain 4 Uninsulated attic space
  • 5.8 Maintenance
  • 5.9 Repair
  • 6 Rail heating
  • 6.1 Application description
  • 6.2 Design information
  • 6.3 Thermal design
  • 50 W/m of rail to 200 W/m of rail, with certain track systems requiring up to 500 W/m. These
  • 6.4 Electrical design
  • 6.5 Control and monitoring system design
  • 6.6 Special design considerations
  • 6.7 Installation
  • 1 Cold lead 3 Trace heater
  • 2 Clip 4 X – X shows a typical cross-section
  • 1 Clip 2 Trace heater
  • 1 Trace heater
  • 1 Trace heater 2 Clip
  • 1 Trace heater
  • 6.8 Maintenance

INTRODUCTION IEC/IEEE 62395-1 provides the essential requirements and testing appropriate to electrical resistance trace heating equipment used in industrial and commercial applications. While some of this work already exists in national or international standards, this document has collated much of this existing work and added considerably to it.

IEC/IEEE 62395-2 provides detailed recommendations for the system design, installation, maintenance and repair of electrical resistance trace heating systems in industrial and commercial applications which can include piping, vessels, roofs and concrete slab heating applications.

It is the objective of the IEC/IEEE 62395 series that, when in normal use, electrical trace heating systems operate safely under their defined conditions of use, by a) employing heaters of the appropriate construction so as to meet the test criteria and requirements detailed in IEC/IEEE 62395-1. The construction includes a metallic sheath, braid, screen or equivalent electrically conductive covering; b) operating at safe temperatures when designed, installed, and maintained in accordance with IEC/IEEE 62395-2; c) having at least the minimum levels of overcurrent and earth-fault protection required in IEC/IEEE 62395-1 and IEC/IEEE 62395-2.

SIST EN IEC 62395-2:2026

ELECTRICAL RESISTANCE TRACE HEATING SYSTEMS FOR INDUSTRIAL AND COMMERCIAL APPLICATIONS –

Part 2: Application guide for system design, installation and maintenance

1 Scope

This part of IEC/IEEE 62395 provides detailed recommendations for the system design, installation, maintenance and repair of electrical resistance trace heating systems in industrial and commercial applications. This document does not include or provide for any applications in potentially explosive atmospheres.

This document pertains to trace heating systems that can comprise either factory fabricated or field-assembled (work-site) units, and which can be series or parallel trace heaters, or surface heaters (heater pads or heater panels) that have been assembled and/or terminated in accordance with the manufacturer's instructions.

The products covered by this document are intended to be installed by persons who are suitably trained in the techniques required and that only trained personnel carry out especially critical work, such as the installation of connections and terminations. Installations are intended to be carried out under the supervision of a qualified person who has undergone supplementary training in electric trace heating systems.

This document does not cover induction, impedance or skin effect heating. Trace heating systems and surface heating systems can be grouped into different types of installations. These are characterized by different requirements for testing and are usually certified for a specific type of installation or application. Typical applications for the different types of installation are shown in Table 1.

Table 1 – Trace heater and surface heater types and related attributes Trace heater type Intended installations Examples of installations Required attributes A Insulated surfaces Hot water lines Dielectric, thermal, (including pipe) Freeze protection mechanical, moisture Grease lines exclusion, and performance Fuel oil lines characteristics verification Pre-insulated pipe Sprinkler system verification Below grade trace heating (if specified for use) Sprinkler systems B Outdoor exposed areas Roof deicing Dielectric, thermal, Gutter and downspouts deicing mechanical, moisture Catch basins and drains exclusion, and performance Rail heating systems characteristics verification Increased moisture resistance UV and condensation resistance Resistance to cutting Abrasion resistance Tension test Rail system tests (if specified for use)

SIST EN IEC 62395-2:2026

Trace heater type Intended installations Examples of installations Required attributes C Installations with Embedded snow melting Dielectric, thermal, embedded trace heating Embedded frost heave protection mechanical, moisture Embedded floor warming exclusion, and performance Embedded energy storage characteristics verification systems Resistance to cutting Embedded door frames Resistance to crushing D Installations with trace Embedded snow melting Dielectric, thermal, heater inside conduit or Embedded frost heave protection mechanical, moisture piping Embedded floor warming exclusion, and performance Embedded energy storage characteristics verification systems Increased moisture Embedded door frames resistance (pressurized or Internal trace heating for freeze non-pressurized) protection of potable water lines Enclosed drains and culverts Pull-strength evaluation NOTE Trace heating systems intended for use in explosive atmospheres are the subject of IEC/IEEE 60079-30-1 and IEC/IEEE 60079-30-2.

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.

IEC/IEEE 62395-1:2024, Electrical resistance trace heating systems for industrial and commercial applications – Part 1: General and testing requirements

3 Terms and definitions

For the purposes of this document, the terms and definitions given in IEC/IEEE 62395-1 apply. ISO, IEC and IEEE maintain terminology databases for use in standardization at the following addresses:

 IEC Electropedia: available at https://www.electropedia.org/  ISO Online browsing platform: available at https://www.iso.org/obp  IEEE Standards Dictionary Online: available at http://dictionary.ieee.org NOTE General definitions are given in the International Electrotechnical Vocabulary, IEC 60050 (all parts).

4 Surface heating of vessels and piping systems

4.1 Application description

4.1.1 General

Piping and vessels often utilise surface-mounted trace heating systems to maintain water above freezing-point and to maintain process fluids and gases at given temperature levels. The trace heaters compensate for heat losses to the environment that are reduced but not eliminated by thermal insulation.

SIST EN IEC 62395-2:2026

Equipment subject to ultraviolet exposure can degrade due to surface oxidation, which can possibly lead to surface embrittlement and cracking. Corrosive atmospheres can affect the same exposed surfaces and can accelerate degradation of surfaces that are also susceptible to ultraviolet exposure. Chemical exposure can affect all equipment, whether covered by thermal insulation or not.

The trace heating equipment for piping and vessels is often protected from corrosion and ultraviolet exposure to some degree by the thermal insulation. However, these systems can have components that are exposed to the environment such as electrical connection components and weather barrier around the thermal insulation. The selection of trace heating equipment should include a review of the suitability of equipment to the expected environmental conditions.

4.1.3 Trace heating systems considerations

Trace heating systems can range from simple pipe freeze protection in commercial buildings to process temperature maintenance and heat-up applications in large complex piping/vessel systems in industrial facilities. The details required for design can vary based on the complexity of the application. Control systems and requirements for monitoring can also vary depending on the control and design requirements.

Trace heating equipment should be chosen that is suitable for the application. For example, plastic piping has a much lower maximum exposure temperature than metallic piping. The trace heating and control system should keep the piping temperature within the allowed range. Higher temperature processes should utilize trace heating and thermal insulation equipment that are suitable for the maximum exposure temperatures.

4.2 Design information – General

4.2.1 General

The requirements for system design include the development of basic heat loss (load) requirements, installation instructions for electrical, control and monitoring requirements, and trace heating system layouts for large, detailed, complex installations such as industrial facilities. While each design component requires individual treatment, the final system should be evaluated as an integration of these component parts.

Trace heating system design should conform to all IEC requirements for the use of electrical equipment and to the requirements of this document. Consideration should be given to the maintenance of the trace heating systems to maintain energy efficiency and to routine testing of the installed systems for safe and proper operation.

Persons involved in the design and planning of electric trace heating systems should be suitably trained in all techniques required.

4.2.2 Electrical system design

The evaluation of electrical resistance heating systems includes an initial assessment of energy requirements and the associated electrical distribution equipment. The selection of the type of trace heating equipment and the control equipment affects the requirements of the electrical system design. Additional information is given in 4.4.

SIST EN IEC 62395-2:2026

4.2.3 Control and monitoring
4.2.3.1 General

Controls for trace heating systems are often specified to reduce total energy usage and/or to maintain particular processes within a narrow band. Monitoring systems are used to verify correct system operation and in many cases to provide an indication of electrical problems or temperatures that are out of range. Subclause 4.2.3.2 describes the basic types of controls and monitoring and 4.2.3.3 defines critical applications relative to the control systems. Specific design of control systems is given in 4.5.

4.2.3.2 Recommendations for control

The recommendations for control and monitoring are defined by the type of application. a) Type I A Type I control is for applications where the temperature is maintained above a minimum point. Large blocks of power can be controlled by means of a single control device, such as ambient sensing, and an electrical distribution panel board. Heat input can be provided unnecessarily at times and wide temperature excursions should be tolerable. Energy efficiency can be improved through the use of dead-leg control techniques (see 4.5.10). b) Type II A Type II control is for applications where the temperature should be maintained within a moderate band. Control by pipe-sensing mechanical thermostats is typical. c) Type III A Type III control is for applications where the temperature should be controlled within a narrow band. Electronic pipe-sensing controllers using thermocouple or resistancetemperature detector (RTD) units facilitate field (work site) calibration and provide maximum flexibility in the selection of temperature alarm and monitoring functions. Advanced temperature-sensing systems such as fiber optic distributed temperature sensing can be used for temperature-sensitive fluid applications. Heat input capability can be provided to preheat an empty pipe or raise the fluid temperature, or both, within a specified range and time interval. Type III systems require strict adherence to flow patterns and thermal insulation systems.

4.2.3.3 Control and monitoring for critical applications

If failure of any part of the trace heating system can result in a safety or operability problem, then the trace heating system can be considered to be critical to the application. The temperature control and circuit monitoring requirements of an application can be defined according to the temperature control types described in 4.2.3.2, together with the control level as described in Table 2.

Table 2 – Application types Desired accuracy of temperature control Is trace heating a critical component for Above a minimum point Within a moderate band Within a narrow band the application?

Type I Type II Type III Yes = Critical (C–) C – I C – II C – III No = Non-Critical (NC–) NC – I NC – II NC – III

When trace heating is critical to the application, circuit monitoring for correct operation, malfunction alarms, and back-up (redundant) trace heaters should be considered. Redundant trace heaters can allow maintenance or repairs to be performed without a process shutdown and can be used to enhance reliability. Redundant controllers can be specified to be automatically activated in the event of a fault being indicated by the monitoring/alarm system.

SIST EN IEC 62395-2:2026

4.2.4 Trace heating system design

Trace heaters should be selected to provide sufficient power for a) compensation of heat loss when maintaining a specified temperature of an application, see the calculation method in 4.3.4; and/or b) raising the temperature of a workpiece and its contents when specified, within a specified time period, see the calculation method in 4.3.6.

The evaluation should provide an electrical system with sufficient capacity to deliver the required power at the specified minimum ambient temperature. The system heat requirements should be multiplied by a safety factor as determined on the basis of 4.3.5. Additional specific design recommendations are described in 4.5.11.

4.2.5 Design information documentation

Design information can be compiled and provided in the form of specifications, layouts, and other system documentation and drawings. Any or all of the following can be applicable:

  • thermal design parameters;
  • system flow diagram;
  • equipment layout drawings (plans, sections, etc.);
  • pipe drawings (plans, isometrics, line lists, etc.);
  • piping specifications;
  • thermal insulation specifications;
  • equipment detail drawings (pumps, valves, strainers, etc.);
  • electrical drawings (one lines, elementaries, etc.);
  • bill of materials;
  • electrical equipment specifications;
  • equipment installation and instruction manuals;
  • equipment details;
  • thermal insulation schedules;
  • process procedures that would cause elevated pipe temperatures, that is, steam out or exothermic reactions.

4.3 Thermal system design

4.3.1 General

Trace heater selection includes the determination of the maximum possible system temperature under worst-case conditions. The evaluation should help ensure that the maximum system temperature does not exceed the maximum withstand temperature rating of the workpiece or the thermal insulation. The trace heating supplier should also provide recommendations for these applications, including product performance and installation guidelines. The trace heater sheath temperature and/or the maximum workpiece temperature can be reduced by, for example, the use of multiple tracers to reduce the power produced per unit length or by the selection of the temperature control system.

Subclause 4.3 reviews design parameters, thermal insulation considerations, system heat loss, safety factors, heat-up considerations, selection of trace heater, design calculations, sheath temperature calculations, design documentation, start-up at low ambient temperatures, long trace heater circuits, and chimney effect.

SIST EN IEC 62395-2:2026

4.3.2 Design conditions

The following general design conditions and application inputs are typically needed prior to commencing with the system design. Additional information that can be required for particular applications is detailed in 4.5.11.

a) System parameters:

1) pipe and vessel maintain temperature; 2) minimum ambient temperature; 3) insulation thickness and type; 4) pipe diameters, lengths, and routing (vertical, horizontal, oblique) or vessel dimensions; 5) pipe type:

i) non-metallic; ii) metallic; 6) components such as pumps, strainers, flanges, valves, and supports; 7) maximum process temperature (due to process, steam cleaning, etc.); 8) flow characteristics:

i) pressurized; ii) gravity; 9) design wind velocity.

b) Electrical considerations:

1) voltage supply; 2) circuit locations; 3) power distribution system.

4.3.3 Thermal insulation
4.3.3.1 General

The selection, installation and maintenance of thermal insulation should be considered a key component in the performance of an electrical trace heating system. The thermal insulation system is normally designed to prevent the majority of heat loss with the trace heating system compensating for the remainder. Therefore, problems with thermal insulation have a direct impact on the overall system performance.

The principal areas for consideration are as follows:

  • selection of an insulating material;
  • selection of a weather barrier (cladding);
  • selection of the economic insulation thickness;
  • the double insulation method.
4.3.3.2 Selection of insulating material

The following are important aspects to be considered when selecting an insulation material. These factors should be considered and the selection optimized according to the following design criteria:

  • temperature rating;
  • thermal conductivity of the insulation;
  • mechanical properties;
  • chemical compatibility and corrosion resistance;

SIST EN IEC 62395-2:2026

  • moisture resistance;
  • health risks during installation;
  • fire resistance;
  • toxicological properties when exposed to fire;
  • costs.

Insulating materials commonly available include:

  • expanded silica;
  • mineral fibre;
  • cellular glass;
  • urethane;
  • fibreglass;
  • calcium silicate;
  • polyisocyanurate;
  • perlite silicate.
  • aerogel For soft insulants (mineral fibre, fibreglass, etc.), actual pipe size insulation can be used in many cases by banding the insulation tightly. Care should be taken to prevent the trace heater from being buried within the insulation, which can cause damage to the trace heater or can possibly restrict proper heat transfer. As an alternative, the next larger pipe size insulation that can easily enclose pipe and electric trace heater is also acceptable. Rigid insulation (calcium silicate, expanded silica, cellular glass, etc.), can be pipe-size insulation if customized to fit the longitudinal joint. In all cases, the insulation type, size and thickness should be clearly specified. Insulation for valves, flanges, pumps, instruments, and other irregularly shaped equipment are typically custom fit for the particular configuration. This can be fabricated from block, insulation segments or flexible removable covers.

Insulating cements or fibrous materials should be used to fill cracks and joints. Where used for total insulation of an irregular surface, a proportionally thicker layer of insulating cement can be applied to achieve the desired insulating capability. When using insulating cement, install a barrier over the trace heater to prevent the insulating cement from isolating the trace heater cable from the workpiece (creating excessive heater temperatures). Embedding the trace heater in insulation cements should generally be avoided.

4.3.3.3 Selection of weather barrier (cladding)

Proper operation of an electrically trace heated system depends upon the insulation being dry. Electric tracing normally has insufficient heat output to dry out wet thermal insulation. Some insulation materials, even though removed from the piping and force dried, never regain their full insulating capability once they have been wet.

...