Radio-frequency connectors - Part 26: Sectional specification of TNCA series RF coaxial connector

This part of IEC 61169 which is a sectional specification (SS) provides information and rules for the preparation of detail specifications (DS) for TNCA series RF coaxial connectors, with characteristic impedance of 50 O, with threaded coupling and operating frequency limit up to 18 GHz, used in wireless, communication, instrument, antenna, test and measurements, radar, and other fields, connecting with RF cables or micro-strips. It also prescribes mating face dimensions for general connectors-grade 2, dimensional details of standard test connectors-grade 0, gauging information and tests selected from IEC 61169-1, applicable to all detail specifications relating to TNCA series connectors. This specification indicates the recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H (see Tables 8 and 9). TNCA connectors are recommended for applications above 11 GHz. TNCA connectors are compatible with TNC connectors as described in the IEC 60169-17 and IEC 60169-26 provided that the dielectric of connector with socket-centre contact does not extend beyond reference plane. However when mated with these connectors, the performances are not ensured.

Hochfrequenz-Steckverbinder - Teil 26: Rahmenspezifikation für koaxiale HF-Steckverbinder der TNCA-Serie

Connecteurs pour fréquences radioélectriques - Partie 26: Spécification intermédiaire pour les connecteurs coaxiaux RF série TNCA

La CEI 61169-26:2013 est une spécification intermédiaire qui fournit des informations et des règles en vue de l'établissement de spécifications particulières de connecteurs coaxiaux RF de série TNCA d'une impédance de 50 Ohms, doté d'un couplage fileté et d'une limite de fréquence de fonctionnement de 18 GHz, utilisés dans les domaines de la communication et des appareils sans fil, des antennes, des essais et des mesures, des radars ainsi que dans d'autres domaines, permettant la connexion avec les câbles RF ou les microrubans. Elle prescrit également les dimensions des faces d'accouplement pour des connecteurs d'usage général classe 2, les détails dimensionnels des connecteurs d'essai normalisés classe 0, les informations concernant les calibres et les essais choisis dans la CEI 61169-1 applicables à toutes les spécifications particulières ayant trait aux connecteurs de la série TNCA.

Radiofrekvenčni konektorji - 26. del: Področna specifikacija za koaksialni radiofrekvenčni (RF) konektor serije TNCA (IEC 61169-26:2013)

General Information

Status
Published
Publication Date
02-Jan-2014
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
16-Dec-2013
Due Date
20-Feb-2014
Completion Date
03-Jan-2014

Buy Standard

Standard
EN 61169-26:2014
English language
29 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 61169-26:2014
01-februar-2014
5DGLRIUHNYHQþQLNRQHNWRUMLGHO3RGURþQDVSHFLILNDFLMD]DNRDNVLDOQL
UDGLRIUHNYHQþQL 5) NRQHNWRUVHULMH71&$ ,(&
Radio-frequency connectors - Part 26: Sectional specification of TNCA series RF coaxial
connector
Hochfrequenz-Steckverbinder - Teil 26: Rahmenspezifikation für koaxiale HF-
Steckverbinder der TNCA-Serie
Connecteurs pour fréquences radioélectriques - Partie 26: Spécification intermédiaire
pour les connecteurs coaxiaux RF série TNCA
Ta slovenski standard je istoveten z: EN 61169-26:2013
ICS:
33.120.30 5DGLRIUHNYHQþQLNRQHNWRUML R.F. connectors
5)
SIST EN 61169-26:2014 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 61169-26:2014

---------------------- Page: 2 ----------------------

SIST EN 61169-26:2014

EUROPEAN STANDARD
EN 61169-26

NORME EUROPÉENNE
April 2013
EUROPÄISCHE NORM

ICS 31.220.10


English version


Radio-frequency connectors -
Part 26: Sectional specification for TNCA series RF coaxial connectors
(IEC 61169-26:2013)


Connecteurs pour fréquences Hochfrequenz-Steckverbinder -
radioélectriques - Teil 26: Rahmenspezifikation für koaxiale
Partie 26: Spécification intermédiaire pour HF-Steckverbinder der TNCA-Serie
les connecteurs coaxiaux RF série TNCA (IEC 61169-26:2013)
(CEI 61169-26:2013)





This European Standard was approved by CENELEC on 2013-03-05. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the CEN-CENELEC Management Centre or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the CEN-CENELEC Management Centre has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany,
Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland,
Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Management Centre: Avenue Marnix 17, B - 1000 Brussels


© 2013 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61169-26:2013 E

---------------------- Page: 3 ----------------------

SIST EN 61169-26:2014
EN 61169-26:2013 - 2 -

Foreword
The text of document 46F/220/FDIS, future edition 1 of IEC 61169-26, prepared by SC 46F, R.F. and
microwave passive components, of IEC TC 46, Cables, wires, waveguides, R.F. connectors, R.F. and
microwave passive components and accessories was submitted to the IEC-CENELEC parallel vote and
approved by CENELEC as EN 61169-26:2013.
The following dates are fixed:
(dop) 2013-12-05
• latest date by which the document has
to be implemented at national level by
publication of an identical national
standard or by endorsement
• latest date by which the national (dow) 2016-03-05
standards conflicting with the

document have to be withdrawn

Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such patent
rights.
Endorsement notice
The text of the International Standard IEC 61169-26:2013 was approved by CENELEC as a European
Standard without any modification.

---------------------- Page: 4 ----------------------

SIST EN 61169-26:2014
- 3 - EN 61169-26:2013
Annex ZA
(normative)

Normative references to international publications
with their corresponding European publications

The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.

NOTE  When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.

Publication Year Title EN/HD Year

IEC 60068-1 - Environmental testing - EN 60068-1 -
Part 1: General and guidance


IEC 61169-1 1992 Radio-frequency connectors - EN 61169-1 1994
+ A1 1996 Part 1: Generic specification - General + A1 1996
+ A2 1997 requirements and measuring methods + A2 1997

---------------------- Page: 5 ----------------------

SIST EN 61169-26:2014

---------------------- Page: 6 ----------------------

SIST EN 61169-26:2014




IEC 61169-26

®


Edition 1.0 2013-01




INTERNATIONAL



STANDARD




NORME



INTERNATIONALE
colour

inside










Radio-frequency connectors –

Part 26: Sectional specification for TNCA series RF coaxial connectors




Connecteurs pour fréquences radioélectriques –

Partie 26: Spécification intermédiaire pour les connecteurs coaxiaux RF série

TNCA















INTERNATIONAL

ELECTROTECHNICAL

COMMISSION


COMMISSION

ELECTROTECHNIQUE

PRICE CODE
INTERNATIONALE

CODE PRIX U


ICS 31.220.10 ISBN 978-2-83220-624-9



Warning! Make sure that you obtained this publication from an authorized distributor.

Attention! Veuillez vous assurer que vous avez obtenu cette publication via un distributeur agréé.

® Registered trademark of the International Electrotechnical Commission
Marque déposée de la Commission Electrotechnique Internationale

---------------------- Page: 7 ----------------------

SIST EN 61169-26:2014
– 2 – 61169-26 © IEC:2013

CONTENTS
FOREWORD . 4
1 Scope . 6
2 Normative reference . 6
3 Mating face and gauge information . 6
3.1 Dimensions – General connectors – Grade 1 . 6
3.1.1 Connector with pin-centre contact (see Figure 1) . 6
3.1.2 Connector with socket-centre contact (see Figure 2) . 8
3.2 Gauges . 9
3.2.1 Gauge pins for socket-centre contact (see Figure 3) . 9
3.2.2 Test procedure . 9
3.3 Dimensions – Standard test connectors – Grade 0 . 10
3.3.1 Connector with pin-centre contact (see Figure 4) . 10
3.3.2 Connector with socket-centre contact (see Figure 5) . 11
4 Quality assessment procedure . 12
4.1 General . 12
4.2 Rating and characteristics (see Clause 6 of IEC 61169-1:1992) . 12
4.3 Test schedule and inspection requirements – Acceptance tests . 15
4.3.1 Acceptance tests (see Table 8) . 15
4.3.2 Periodic tests. 16
4.4 Procedures . 18
4.4.1 Quality conformance inspection . 18
4.4.2 Qualification approval and its maintenance . 18
5 Instructions for preparation of detail specifications . 19
5.1 General . 19
5.2 Identification of the component . 19
5.3 Performance . 19
5.4 Marking, ordering information and related matters . 19
5.5 Selection of tests, test conditions and severities . 19
5.6 Blank detail specification pro-forma for type TNCA connector . 21
Bibliography . 26

Figure 1 – Connector with pin-centre contact (for dimensions and key, see Table 1) . 7
Figure 2 – Connector with socket-centre contact (for dimensions and key, see Table 2) . 8
Figure 3 – Gauge pins for socket-centre contact (for dimensions, see Table 3) . 9
Figure 4 – Connector with pin-centre contact (for dimensions and key, see Table 4) . 10
Figure 5 – Connector with socket-centre contact (for dimensions and key, see Table 5) . 11

Table 1 – Dimensions of connector with pin-centre contact . 7
Table 2 – Dimensions of connector with socket-centre contact . 8
Table 3 – Dimensions of gauge pins for socket-centre contact . 9
Table 4 – Dimensions of connector with pin-centre contact . 10
Table 5 – Dimensions of connector with socket-centre contact . 11
Table 6 – Preferred climatic categories (see IEC 60068-1) . 12
Table 7 – Ratings and characteristics . 13

---------------------- Page: 8 ----------------------

SIST EN 61169-26:2014
61169-26 © IEC:2013 – 3 –
Table 8 – Acceptance tests . 15
Table 9 – Periodic tests . 16

---------------------- Page: 9 ----------------------

SIST EN 61169-26:2014
– 4 – 61169-26 © IEC:2013
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________

RADIO-FREQUENCY CONNECTORS –

Part 26: Sectional specification for TNCA series
RF coaxial connectors


FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61169-26 has been prepared by subcommittee 46F: RF and
microwave passive components, of IEC technical committee 46: Cables, wires, waveguides,
R.F. connectors, R.F. and microwave passive components and accessories.
The text of this standard is based on the following documents:
FDIS Report on voting
46F/220/FDIS 46F/225/RVD

Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.

---------------------- Page: 10 ----------------------

SIST EN 61169-26:2014
61169-26 © IEC:2013 – 5 –
A list of all parts of the IEC 61169 series, under the general title: Radio-frequency connectors,
can be found on the IEC website.
The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.

IMPORTANT – The 'colour inside' logo on the cover page of this publication indicates
that it contains colours which are considered to be useful for the correct
understanding of its contents. Users should therefore print this document using a
colour printer.

---------------------- Page: 11 ----------------------

SIST EN 61169-26:2014
– 6 – 61169-26 © IEC:2013
RADIO-FREQUENCY CONNECTORS –

Part 26: Sectional specification for TNCA series
RF coaxial connectors



1 Scope
This part of IEC 61169 which is a sectional specification (SS) provides information and rules
for the preparation of detail specifications (DS) for TNCA series RF coaxial connectors, with
characteristic impedance of 50 Ω, with threaded coupling and operating frequency limit up to
18 GHz, used in wireless, communication, instrument, antenna, test and measurements,
radar, and other fields, connecting with RF cables or micro-strips.
It also prescribes mating face dimensions for general connectors-grade 2, dimensional details
of standard test connectors-grade 0, gauging information and tests selected from
IEC 61169-1, applicable to all detail specifications relating to TNCA series connectors.
This specification indicates the recommended performance characteristics to be considered
when writing a detail specification and it covers test schedules and inspection requirements
for assessment levels M and H (see Tables 8 and 9).
TNCA connectors are recommended for applications above 11 GHz. TNCA connectors are
compatible with TNC connectors as described in the IEC 60169-17 and IEC 60169-26
provided that the dielectric of connector with socket-centre contact does not extend beyond
reference plane. However when mated with these connectors, the performances are not
ensured.
NOTE Attention is drawn to the fact that TNCA interface does not utilize overlapping PTFE dielectric for increased
voltage breakdown resistance.
2 Normative reference
The following documents, in whole or in part, are normatively referenced in this document and
are indispensable for its application. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any
amendments) applies.
IEC 61169-1:1992, Radio-frequency connectors – Part 1: Generic specification – General
1
requirements and measuring methods
Amendment 1:1996
Amendment 2:1997
IEC 60068-1, Environmental testing – Part 1: General and guidance
3 Mating face and gauge information
3.1 Dimensions – General connectors – Grade 1
3.1.1 Connector with pin-centre contact (see Figure 1)
Metric dimensions are original dimensions.
___________
1
 There exists a consolidated edition 1.2 (1998) that comprises IEC 61169-1:1992, its Amendment 1:1996 and its
Amendment 2:1997.

---------------------- Page: 12 ----------------------

SIST EN 61169-26:2014
61169-26 © IEC:2013 – 7 –
All undimensioned pictorial configurations are for reference purpose only.



 Reference plane f


e

Sealing gasket to meet required functional
(1) m g
and environmental performance
55°∼ 66°
1°∼ 4°
ad k
h
 Detail for pin contact
Note 2
Reference
(2)
p
n
plane
Full theard IEC  269/13


Figure 1 – Connector with pin-centre contact
(for dimensions and key, see Table 1)
Table 1 – Dimensions of connector with pin-centre contact
Ref. mm inch
Additional
notes
Min. Max. Min. Max.
a 11,18 - 0,440 -
b 7,98 8,08 0,314 0,318
c 6,05 6,15 0,238 0,242

d 1,32 1,37 0,052 0,054
e 5,28 - 0,208 -

f 5,38 - 0,212 -
g 5,28 - 0,208 -
h 0,08 - 0,003 -
k 1,98 - 0,078 -
m - 1,98 - 0,078 (1)
n 1,60 - 0,063 -
p 3,96 - 0,156 -
r - 0,64 - 0,025
s - 8,18 - 0,322
ad 3,66 3,98 0,144 0,157
(1) This dimension shows the position with nut biased fully forward.
(2) Three holes 0,69 mm (0,027 inch) minimum diameter equally spaced for safety wiring when required.
Location of holes on coupling nut is optional and consistent with electrical/mechanical performance.

∅a
7/16-28UNEF-2B
∅b
∅c
∅s
∅r
∅d

---------------------- Page: 13 ----------------------

SIST EN 61169-26:2014
– 8 – 61169-26 © IEC:2013
3.1.2 Connector with socket-centre contact (see Figure 2)
p
 Reference plane
j
k
Chamfer or radius
t
I
s
f h Detail for socket contact
g
r
IEC  270/13

Figure 2 – Connector with socket-centre contact
(for dimensions and key, see Table 2)
Table 2 – Dimensions of connector with socket-centre contact
Ref. mm inch Additional notes
Min. Max. Min. Max.
a 9,60 9,68 0,378 0,381

b 8,79 9,04 0,346 0,356

c 8,31 8,46 0,327 0,333
d 8,10 8,15 0,319 0,321
e 4,62 4,72 0,182 0,186
f 1,73 2,24 0,068 0,088
g 8,31 8,51 0,327 0,335
h 4,75 - 0,187 -
j 5,03 5,28 0,198 0,208
k - 0,15 - 0,006
l 4,95 - 0,195 -
m 2,13 2,21 0,084 0,087
p 5,03 5,28 0,198 0,208
r 10,52 - 0,414 -
s 0,38 0,76 0,015 0,030
t 4,57 4,98 0,180 0,196
u - 2,34 - 0,092 (1)
v   (2)
(1) Diameter u is the ID of dielectric based on the assumption that the dielectric used has a dielectric constant
of 2,02.
(2) Design for slotting is optional. It is chosen to meet electrical and mechanical requirements, when mated
with a 1,32 mm (0,052 in) ~ 1,37 mm (0,054 in) diameter pin.

7/16-28UNEF-2A
∅a
∅b
∅c
∅d
∅e
∅u (1)

∅v (2)

∅m

---------------------- Page: 14 ----------------------

SIST EN 61169-26:2014
61169-26 © IEC:2013 – 9 –

3.2 Gauges
3.2.1 Gauge pins for socket-centre contact (see Figure 3)

R0,4 max.
   50° ± 10°
b
IEC  271/13

Figure 3 – Gauge pins for socket-centre contact
(for dimensions, see Table 3)
Table 3 – Dimensions of gauge pins for socket-centre contact
Gauge A Gauge B
Maximum material for sizing purpose Minimum material for measurement of retention
force
Mass of gauge 60 g ± 2 g
mm in mm in
Min. Max. Min. Max. Min. Max. Min. Max.
a 1,450 1,455 0,057 1 0,057 3 1,315 1,320 0,051 8 0,052 0
b 3,18 3,50 0,125 2 0,137 8 3,18 3,50 0,125 2 0,137 8
Material: steel, polished.
Surface roughness: Ra ≤ 0,4 µm on the cylindrical surface of length b and R0,4.

3.2.2 Test procedure
The gauge A shall be inserted into the socket-centre contact one time with a minimum depth
of 3,18 mm. This is a sizing operation and should only be carried out when the socket-centre
contact is removed from the connector.
After this, the gauge B shall be inserted into the socket-centre contact. The contact shall
retain the mass of the gauge in a vertical downward position. The test shall be carried out on
connector when the socket-centre contact is not removed.
∅a
∅0,2 max.

---------------------- Page: 15 ----------------------

SIST EN 61169-26:2014
– 10 – 61169-26 © IEC:2013
3.3 Dimensions – Standard test connectors – Grade 0
3.3.1 Connector with pin-centre contact (see Figure 4)

∅0,013 mm
C
∅0,0005 in
∅0,013 mm
∅0,0005 in
Reference plane

f
e

m g
(1)
∅0,05 mm
∅0,08 mm
C
C
∅0,002 in
∅0,003 in
55°∼ 66°
C
0,8
0,8
1°∼ 4°
k
ad

Detail for pin contact
REF Plane
h
Reference
plane
n p
Full theard
IEC  272/13


Figure 4 – Connector with pin-centre contact
(for dimensions and key, see Table 4)
Table 4 – Dimensions of connector with pin-centre contact
Ref. mm inch Additional
notes
Min. Max. Min. Max.
a 11,18 - 0,440 -
b 8,06 8,08 0,317 3 0,318 1
c 6,07 6,12 0,239 0,241
d 1,34 1,37 0,053 0,054
e 5,28 - 0,208 -
f 5,38 - 0,212 -
g 5,28 - 0,208 -
h 0,08 1,02 0,003 0,040
k 1,98 - 0,078 -
m - 1,98 - 0,078 (1)
n 1,60 - 0,063 -
p 3,96 - 0,156 -
r - 0,64 - 0,025
s - 8,18 - 0,322
ad 3,66 3,98 0,144 0,157
(1) This dimension shows the position with nut biased fully forward.
∅a
7/16-28UNEF-2B
∅b
∅c
0,8
∅s
∅r
∅d

---------------------- Page: 16 ----------------------

SIST EN 61169-26:2014
61169-26 © IEC:2013 – 11 –
3.3.2 Connector with socket-centre contact (see Figure 5)
 RefREF PLerencANEe plane
p
p
∅0,013 mm
0.013 mm
E
E
∅0,0005 in
0.0005 in
j
∅0,10 mm j
φ0.10 mm
0.013 mm
E CHAMFER OR RADIUS ∅0,013 mm
E
φ∅0,00.0004 i4 nin
Chamfer or radius
0.0005 in
∅0,0005 in
k(k NOT(1) E 1)
0.1~0.23mm×45°
EE 0,1 ∼ 0,23 mm × 45°
φ0.1∅0,100 mm mm
E E
φ0.004 in
∅0,004 in
tt
I
l
s
s
Detail for socket contact
Detail for socket contact
f h
f h
g
g
r
IEC  273/13
r

Figure 5 – Connector with socket-centre contact
(for dimensions and key, see Table 5)
Table 5 – Dimensions of connector with socket-centre contact
Ref. mm inch Additional
notes
Min. Max. Min. Max.
a 9,60 9,68 0,378 0,381
b 8,79 9,04 0,346 0,356
c 8,31 8,46 0,327 0,333
d 8,10 8,15 0,319 0,321
e 4,62 4,72 0,182 0,186
f 1,73 2,24 0,068 0,088
g 8,31 8,51 0,327 0,335
h 4,73 - 0,187 -
j 5,03 5,28 0,198 0,208
k - 0,15 - 0,006 (1)
l 4,95 - 0,195 -
m 2,18 2,21 0,086 0,087
p 5,18 5,28 0,204 0,208
r 10,52 - 0,414 -
s 0,38 0,76 0,015 0,030
t 4,57 4,98 0,180 0,196
u 2,24 2,34 0,088 0,092 (2)
v 1,38 1,41 0,054 3 0,055 5 (3)
(1) Dimension k applies to that portion (if applicable) of the dielectric which protrudes beyond the reference
plane.
(2) Diameter u is the ID of dielectric based on the assumption that the dielectric used has a dielectric constant
of 2,02.
(3) Design for slotting is optional. It is chosen to meet electrical and mechanical requirements, when mated with
a 1,32 mm (0,052 in) ~ 1,37 mm (0,054 in) contact.
7/16-28UNEF-2A
7/16-28UNEF-2A
∅a
φa
∅b
φb
∅c
φc
∅d
φd
∅e
φe
∅u (2)

φu(NOTE 2)

∅v (3)
φv(NOTE 3 )
φ∅mm

---------------------- Page: 17 ----------------------

SIST EN 61169-26:2014
– 12 – 61169-26 © IEC:2013
4 Quality assessment procedure
4.1 General
The following subclauses provide recommended rating, performance and test conditions to be
considered when writing a detail specification. They also provide an appropriate schedule of
tests with minimum levels of conformance inspection sampling, together with the pro-forma
blank detail specification (BDS) and instructions for the preparation of a detail specification.
4.2 Rating and characteristics (see Clause 6 of IEC 61169-1:1992)
The values indicated below are recommended for TNCA series RF connectors and are given
for the writer of the detail specification. They are applicable for the condition when the
connectors are fully mated.
Certain tests are listed without any recommended values being given. Test requirements are
shown in Tables 8 and 9 and when such tests are required, appropriate values shall be
entered in the detail specification at the discretion of the specification writer.
Climatic categories are given in Table 6 while ratings and characteristics are given in Table 7.
Table 6 – Preferred climatic categories (see IEC 60068-1)
Category Letter Temperature range Damp heat steady state
°C
designation *
40/85/21 A –40 to +85 21 days
55/155/56 B –55 to +155 56 days
* To be included in the IEC type designation.

---------------------- Page: 18 ----------------------

SIST EN 61169-26:2014
61169-26 © IEC:2013 – 13 –
Table 7 – Ratings and characteristics
Ratings and characteristics IEC 61169- Values Remarks,
1:1992 deviations from
Subclause standard
test method
Electrical
Nominal impedance
50 Ω
Frequency range  Up to 18 GHz Or upper
frequency limit of
cable
a
Reflection factor 9.2.1 0,05 GHz to18 GHz
 Grade 1 connectors
– For semi-rigid and semi-flexible cable
 – straight styles 0,048+0,0035f, max.
 – right-angle styles See DS
– For flexible cable
 – straight styles See DS
 – right-angle styles See DS
– component mounting styles See DS
– solder bucket and PCB mounting styles See DS
b
Centre contact resistance 9.2.3
– initial
≤ 1,5 mΩ
– after conditioning
≤ 3,0 mΩ
b
Outer conductor resistance 9.2.3
– initial
≤ 0,4 mΩ
– after conditioning
≤ 1,2 mΩ

Insulation resistance 9.2.5
– initial  ≥ 5 000 MΩ
– after conditioning
≥ 200 MΩ
c, d
Proof voltage at sea level 9.2.6 1 500 V
c, d
Proof voltage at 4,4 kPa 9.2.6 375 V 4,4 kPa
approximately
equivalent to
20 km
c, d
Environmental test voltage at sea level 9.2.6 500 V
c, d
Environmental test voltage at 4,4 kPa 9.2.6 125 V 4,4 kPa
approximately
equivalent to
20 km
Screening effectiveness (straight cabled 9.2.8 ≥ 90 dB at 1 GHz
e
connectors only)

Discharge test (corona effect) 9.2.9 375 V Extinction voltage
at 4,4k Pa
Mechanical

Gauge retention force (resilient contacts)
– centre 9.3.4
≥ 0,6 N
Centre contact captivation 9.3.5 Conform with
interface
– axial force  26,7 N
f
– axial torque na

---------------------- Page: 19 ----------------------

SIST EN 61169-26:2014
– 14 – 61169-26 © IEC:2013
Ratings and characteristics IEC 61169- Values Remarks,
1:1992 deviations from
Subclause standard
test method
Engagement and separation 9.3.6 Can be carried out
by hand
Engagement na
Separation
≤ 0,23 N·m
Technical tests on cable fixing
– cable rotation (nutation) 9.3.7 See DS
– cable pulling 9.3.8 See DS
– cable bending 9.3.9 See DS
– cable torsion 9.3.10 See DS
Tensile strength of coupling mechanism 9.3.11
≥ 444,8 N
Bending moment 9.3.12 Relative to
1 N·m
reference plane
2
Vibration 9.3.3 150 m/s  15 g
n

10 Hz to 2 000 Hz
2
Shock 9.3.14 750 m/s 75 g
n
 Saw tooth wave,
6 ms
Environmental
Climatic category 9.4.2 55/155/21
Sealing non-hermetic 9.4.5.1 100 kPa to
3
≤ 1 cm /h 110 kPa
differential
3
Hermetic 9.4.5.2 ≤ 1 Pa· cm /s
Salt mist 9.4.6 48 h spraying
Endurance
Mechanical endurance 9.5 500 operations
g
High temperature endurance 9.6 250 h at 155 °C
a
These values apply to basic connectors. In practice, they are influenced by the ca
...