oSIST ISO/DIS 11277:2025
(Main)Soil quality - Determination of particle size distribution in mineral soil material - Method by sieving and sedimentation
- Abstract
This document specifies a basic method of determining the particle size distribution applicable to a wide range of mineral soil materials, including the mineral fraction of organic soils. It also offers procedures to deal with the less common soils mentioned in the introduction. This document has been developed largely for use in the field of environmental science, and its use in geotechnical investigations is something for which professional advice might be required.
A major objective of this document is the determination of enough size fractions to enable the construction of a reliable particle-size-distribution curve.
This document does not apply to the determination of the particle size distribution of the organic components of soil, i.e. the more or less fragile, partially decomposed, remains of plants and animals. It is also realized that the chemical pre-treatments and mechanical handling stages in this document could cause disintegration of weakly cohesive particles that, from field inspection, might be regarded as primary particles, even though such primary particles could be better described as aggregates. If such disintegration is undesirable, then this document is not used for the determination of the particle size distribution of such weakly cohesive materials.
- Status
- Not Published
- Public Enquiry End Date
- 02-Nov-2025
- Technical Committee
- KAT - Soil quality
- Current Stage
- 4020 - Public enquire (PE) (Adopted Project)
- Start Date
- 18-Aug-2025
- Due Date
- 05-Jan-2026
- Completion Date
- 18-Sep-2025
Buy Documents
ISO/FDIS 11277 - Soil quality — Determination of particle size distribution in mineral soil material — Method by sieving and sedimentation
REDLINE ISO/FDIS 11277 - Soil quality — Determination of particle size distribution in mineral soil material — Method by sieving and sedimentation
oSIST ISO/DIS 11277:2025, published by ISO, specifies a method for determining the particle size distribution of mineral soil material by sieving and sedimentation. It is written mainly for environmental science work, and it is also used for mineral soil fractions in organic soils, with caution advised for geotechnical investigations.
What does oSIST ISO/DIS 11277:2025 specify?
oSIST ISO/DIS 11277:2025 specifies a basic method for measuring the size distribution of mineral soil material and for building a reliable particle-size-distribution curve from enough size fractions to describe the soil properly. The document covers the main laboratory route from field sampling through dry sieving, wet sieving and sedimentation, plus the test report.
It applies to a wide range of mineral soils, including the mineral fraction of organic soils. The scope excludes the organic components of soil, and it also warns that chemical pretreatments and mechanical handling can break down weakly cohesive particles, which matters if the field structure must be preserved.
The document is organized into clauses for scope, references, terms and definitions, symbols, principle, field sampling, sample preparation, dry sieving for material above 2 mm, wet sieving and sedimentation for material below 2 mm, and the test report. It also includes four informative annexes.
| Annex | What it covers |
|---|---|
| Annex A | Determination of particle size distribution for mineral soil material that is not dried before analysis |
| Annex B | Hydrometer method after destruction of organic matter |
| Annex C | Precision of the method |
| Annex D | Ultrasonic bath assisted wet sieving and sedimentation |
What are the key requirements of oSIST ISO/DIS 11277:2025?
oSIST ISO/DIS 11277:2025 requires a staged approach: representative sampling, ISO 11464 sample preparation, dry sieving above 2 mm, and wet sieving plus sedimentation below 2 mm. The practical point is that the soil is split into measurable fractions so the result is traceable and comparable between laboratories.
Sampling and preparation
Clause 6 says the field sample must be representative, especially where coarse particles are common, and it gives recommended minimum sample masses based on the largest particles present. Clause 7 requires sample preparation in accordance with ISO 11464. In practice, this means the laboratory must start from a sample that can support the fraction sizes that matter for the final curve.
Dry sieving for material above 2 mm
Clause 8 covers material retained on a 2 mm sieve. oSIST ISO/DIS 11277:2025 requires sieves that conform to ISO 565 and ISO 3310-1 or ISO 3310-2, with covers and receivers that do not leak, and it says round-hole sieves shall not be used. The test sieves must be checked regularly, and the apertures used must be stated in the report, so the result can be reproduced and audited.
The clause also says the results shall be based on weighing, not on indirect methods such as radiation or electrical measurements. That matters because the standard is aimed at limiting interlaboratory variation by using one mass-based approach throughout.
Wet sieving and sedimentation below 2 mm
Clause 9 is the core of the method for fine material. oSIST ISO/DIS 11277:2025 uses wet sieving at 0.063 mm and sedimentation for particles smaller than 0.063 mm, and it specifies the pipette method as preferred. The hydrometer method is allowed only in Annex B. This distinction matters because the two methods do not have the same precision, and the report must show which one was used.
The method is built around equivalent spherical diameter and Stokes’ Law. In practice, this means the sedimentation result is an equivalent size, not a direct geometric measurement, so the assumptions of the method need to be respected when deciding whether the result is suitable.
Pretreatments before dispersion
Clause 9 requires removal of organic matter and soluble salts, and it allows optional removal of carbonates and iron oxides when needed. The removal of organic matter is a requirement, except when determining ecologically relevant particle size distribution. The practical consequence is that the lab must decide and document which pretreatments were applied, because they affect whether primary particles or weak aggregates are measured.
The document also requires a dispersing agent and sets checks on electrical conductivity using ISO 11265 to decide when salts and gypsum must be removed. If ultrasonic treatment is used, it is only allowed when comparability with the non-ultrasonic procedure has been demonstrated. That matters because the pretreatment can change the measured fraction sizes.
Sedimentation conditions and calculations
Clause 9 requires a controlled temperature environment for sedimentation, calibrated pipettes, and timed sampling at set intervals. The standard also gives formulas for converting sample masses into fractions and for expressing the proportions of the different size classes. In practice, the lab has to control temperature, timing and weighing closely, because those are the main sources of error in fine-fraction work.
Reporting
Clause 10 requires the report to identify the sample, state the methods used, give the results, record deviations and unusual features, and include the date of analysis. If the hydrometer method is used, Annex B also requires the hydrometer reference number and the particle density used. This makes the result traceable and shows exactly which version of the method was applied.
What terms does oSIST ISO/DIS 11277:2025 define?
oSIST ISO/DIS 11277:2025 uses the following key terms and abbreviations:
- Diameter - Clause 3 defines particle diameter as the diameter of a sphere whose behavior in suspension matches that of the particle.
- Equivalent spherical diameter - the size used throughout the sedimentation work to express how a particle behaves in liquid, not just how it looks.
- Particle size distribution - the proportion of the soil in each size class, which is the main result the method is designed to measure.
- Dispersing agent - a chemical added to keep particles separated so that clay and silt fractions can settle as individual particles rather than flocs.
- Electrical conductivity (γ) - used to judge whether soluble salts and gypsum are high enough to interfere with dispersion.
- Relative centrifugal force (RCF) - used in the pretreatment steps when centrifugation is applied to clear the supernatant.
- Pipette method - the preferred sedimentation route in the main body of the document.
- Hydrometer method - an alternative fine-fraction method described in Annex B.
Who uses oSIST ISO/DIS 11277:2025?
oSIST ISO/DIS 11277:2025 is used by soil laboratories, environmental scientists, and quality managers who need a particle-size distribution for mineral soils. It is also relevant to buyers and laboratory managers who specify soil characterization work and need comparable results from different labs.
The method is especially useful for environmental science work, soil classification support, and investigations that need a full particle-size-distribution curve. Field teams also play a role, because the lab needs field information to choose the right pretreatment path for soils that dry badly, disperse poorly, or contain unusual mineralogy.
What changed in oSIST ISO/DIS 11277:2025 from the previous edition?
oSIST ISO/DIS 11277:2025 is the fourth edition, and it cancels and replaces oSIST ISO/DIS 11277:2025:2020. It also incorporates oSIST ISO/DIS 11277:2025:2020/Amd. 1:2024.
The stated technical changes are that removal of organic substances has been changed from a recommendation to a requirement, with an exception for ecologically relevant particle size distribution, where destruction of organic matter is not necessary. The document also tightens the use of systems with ultrasonic treatment, which are now allowed only under restricted conditions.
Which standards are used with oSIST ISO/DIS 11277:2025?
oSIST ISO/DIS 11277:2025 depends on several named standards for sieves and pretreatment:
- ISO 565 - gives nominal sieve opening sizes for the test sieves used in the method.
- ISO 3310-1 - sets technical requirements and testing for metal wire cloth test sieves.
- ISO 3310-2 - sets technical requirements and testing for perforated metal plate test sieves.
- ISO 11265 - provides the electrical conductivity method used to decide when soluble salts and gypsum must be removed.
- ISO 11464 - provides the sample pretreatment method used before analysis.
What does the oSIST ISO/DIS 11277:2025 document contain?
oSIST ISO/DIS 11277:2025 contains the main calculation route for coarse and fine fractions, plus the supporting apparatus requirements and calibration steps. It includes a flow chart for the overall procedure, a particle-size-distribution chart, a table of recommended sampling masses, a table of sieve load limits, and a table of pipette sampling times at different temperatures.
The document also includes formulas for dry-sieve calculations, sedimentation calculations, hydrometer corrections, and conversion between fractions and total soil mass. Annex B adds calibration curves and a hydrometer recording table, Annex C summarizes precision data from interlaboratory work, and Annex D gives an ultrasonic-assisted procedure with a power calibration approach.
Relations
- Effective Date
- 01-Oct-2025
Buy Documents
ISO/FDIS 11277 - Soil quality — Determination of particle size distribution in mineral soil material — Method by sieving and sedimentation
REDLINE ISO/FDIS 11277 - Soil quality — Determination of particle size distribution in mineral soil material — Method by sieving and sedimentation
Get Certified
Connect with accredited certification bodies for this standard
CIS Institut d.o.o.
Personal Protective Equipment (PPE) certification body. Notified Body NB-2890 for EU Regulation 2016/425 PPE.

Kiwa BDA Testing
Building and construction product certification.
Kmetijski inštitut Slovenije
Agricultural Institute of Slovenia. Soil testing, plant health, agricultural product analysis.
Sponsored listings
Frequently Asked Questions
oSIST ISO/DIS 11277:2025 is a draft published by the Slovenian Institute for Standardization (SIST). Its full title is "Soil quality - Determination of particle size distribution in mineral soil material - Method by sieving and sedimentation". This standard covers: This document specifies a basic method of determining the particle size distribution applicable to a wide range of mineral soil materials, including the mineral fraction of organic soils. It also offers procedures to deal with the less common soils mentioned in the introduction. This document has been developed largely for use in the field of environmental science, and its use in geotechnical investigations is something for which professional advice might be required. A major objective of this document is the determination of enough size fractions to enable the construction of a reliable particle-size-distribution curve. This document does not apply to the determination of the particle size distribution of the organic components of soil, i.e. the more or less fragile, partially decomposed, remains of plants and animals. It is also realized that the chemical pre-treatments and mechanical handling stages in this document could cause disintegration of weakly cohesive particles that, from field inspection, might be regarded as primary particles, even though such primary particles could be better described as aggregates. If such disintegration is undesirable, then this document is not used for the determination of the particle size distribution of such weakly cohesive materials.
This document specifies a basic method of determining the particle size distribution applicable to a wide range of mineral soil materials, including the mineral fraction of organic soils. It also offers procedures to deal with the less common soils mentioned in the introduction. This document has been developed largely for use in the field of environmental science, and its use in geotechnical investigations is something for which professional advice might be required. A major objective of this document is the determination of enough size fractions to enable the construction of a reliable particle-size-distribution curve. This document does not apply to the determination of the particle size distribution of the organic components of soil, i.e. the more or less fragile, partially decomposed, remains of plants and animals. It is also realized that the chemical pre-treatments and mechanical handling stages in this document could cause disintegration of weakly cohesive particles that, from field inspection, might be regarded as primary particles, even though such primary particles could be better described as aggregates. If such disintegration is undesirable, then this document is not used for the determination of the particle size distribution of such weakly cohesive materials.
oSIST ISO/DIS 11277:2025 is classified under the following ICS (International Classification for Standards) categories: 13.080.20 - Physical properties of soils. The ICS classification helps identify the subject area and facilitates finding related standards.
oSIST ISO/DIS 11277:2025 has the following relationships with other standards: It is inter standard links to SIST ISO 11277:2020. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
oSIST ISO/DIS 11277:2025 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Symbols
- 5 Principle
- 6 Field sampling
- 7 Sample preparation
- 8 Dry sieving (material >2 mm)
- 8.1 General
- 8.2 Apparatus
- 8.3 Procedure
- 8.4 Calculation and expression of results
- 9 Wet sieving and sedimentation (material <2 mm)
- 9.1 General
- 9.2 Apparatus
- 9.3 Reagents
- 9.4 Calibrations
- 9.5 Test sample
- 9.6 Destruction of organic matter
- 9.7 Removal of soluble salts and gypsum
- 9.8 Removal of carbonates
- 9.9 Removal of iron oxides
- 9.10 Dispersion
- 9.11 Wet sieving at 0,063 mm
- 9.12 Sedimentation
- 9.13 Calculation of results for fractions <2 mm
- 10 Test report
- Annex A
- Annex B
- Annex C
- Annex D
- Bibliography
Introduction
The physical and chemical behaviour of soils is controlled in part by the amounts of mineral particles of different sizes in the soil. The subject of this document is the quantitative measurement of such amounts (expressed as a proportion or percentage of the total mass of the mineral soil), within stated size classes. The determination of particle size distribution is affected by organic matter, soluble salts, cementing agents (like iron compounds), relatively insoluble substances such as carbonates and sulfates, or combinations of these. Some soils change their behaviour to such a degree, upon drying, that the particle size distribution of the dried material bears little or no relation to that of the undried material encountered under natural conditions. This is particularly true of soils rich in organic matter, those developed from recent volcanic deposits, some highly weathered tropical soils, and soils often described as “cohesive” (see Reference [4]). Other soils, such as the so-called “sub-plastic” soils of Australia, show little or no tendency to disperse under normal laboratory treatments, despite field evidence of large clay content. The procedures given in this document recognize these kinds of differences between soils from different environments, and the methodology presented is designed to deal with them in a structured manner. Such differences in soil behaviour can be very important, but awareness of them depends usually on local knowledge. Given that the laboratory is commonly distant from the site of the field operation, the information supplied by field teams becomes crucial to the choice of an appropriate laboratory procedure. This choice can be made only if the laboratory is made fully aware of this background information.
oSIST ISO/DIS 11277:2025
oSIST ISO/DIS 11277:2025 DRAFT International Standard ISO/DIS 11277:2025(en) Soil quality — Determination of particle size distribution in mineral soil material — Method by sieving and sedimentation WARNING — Persons using this document should be familiar with usual laboratory practice. This document does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user to establish appropriate safety and health practices and to ensure compliance with any national regulatory conditions.
IMPORTANT — It is absolutely essential that tests, conducted in accordance with this document, be carried out by suitably qualified staff.
1 Scope
This document specifies a basic method of determining the particle size distribution applicable to a wide range of mineral soil materials, including the mineral fraction of organic soils. It also offers procedures to deal with the less common soils mentioned in the introduction. This document has been developed largely for use in the field of environmental science, and its use in geotechnical investigations is something for which professional advice might be required.
A major objective of this document is the determination of enough size fractions to enable the construction of a reliable particle-size-distribution curve.
This document does not apply to the determination of the particle size distribution of the organic components of soil, i.e. the more or less fragile, partially decomposed, remains of plants and animals. It is also realized that the chemical pre-treatments and mechanical handling stages in this document could cause disintegration of weakly cohesive particles that, from field inspection, might be regarded as primary particles, even though such primary particles could be better described as aggregates. If such disintegration is undesirable, then this document is not used for the determination of the particle size distribution of such weakly cohesive materials.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 565, Test sieves — Metal wire cloth, perforated metal plate and electroformed sheet — Nominal sizes of openings ISO 3310-1, Test sieves — Technical requirements and testing — Part 1: Test sieves of metal wire cloth ISO 3310-2, Test sieves — Technical requirements and testing — Part 2: Test sieves of perforated metal plate ISO 11265, Soil quality — Determination of the specific electrical conductivity ISO 11464, Soil quality — Pretreatment of samples for physico-chemical analysis
3 Terms and definitions
There are no normative references in this document.
oSIST ISO/DIS 11277:2025 ISO/DIS 11277:2025(en)
4 Symbols
The following symbols are found throughout the text and, where appropriate, units and quantities are as given below (the SI convention is followed for common units, e.g. g = gram; m = metre; mm = millimetre; s = second, etc.).
Mg megagram (10 g)
5 Principle
The particle size distribution is determined by a combination of sieving and sedimentation, starting from air-dried soil (see Reference [4]). A method for undried soil is given in Annex A. Particles not passing a 2 mm aperture sieve are determined by dry sieving. Particles passing such a sieve, but retained on a 0,063 mm aperture sieve, are determined by a combination of wet and dry sieving, whilst particles passing the latter sieve are determined by sedimentation.
The pipette method is preferred. As an alternative, the hydrometer method is given in Annex B. A combination of sieving and sedimentation enables the construction of a continuous particle-size-distribution curve. The key points in this procedure are summarized as a flow chart in Figure 2. This document requires that the proportions of fractions separated by sedimentation and sieving be determined from the masses of such fractions obtained by weighing. Other methods of determining the mass of such fractions rely on such things as the interaction of particles with electromagnetic radiation or electrical fields (see Reference [2]). There are often considerable difficulties in relating the values obtained by these different methods for the same sample. It is one of the intentions of this document that close adherence to its details should help minimize interlaboratory variation in the determination of the particle size distribution of mineral soils. Therefore, the proportions of fractions shall be determined only by weighing. If this is not the method used, then conformance with this document cannot be claimed in the test report (see Clause 10). Both the pipette and hydrometer methods assume that the settling of particles in the sedimentation cylinder is in accordance with Stokes's Law (see References [2], [4] and [7]), and the constraints that this implies, namely:
a) the particles are rigid, smooth spheres; b) the particles settle in laminar flow, i.e. the Reynolds Number is less than about 0,2; this constraint sets an upper equivalent spherical particle diameter (see below) slightly greater than 0,06 mm for Stokesian settling under gravity (Reference [2]); c) the suspension of particles is sufficiently dilute to ensure that no particle interferes with the settling of any other particle; d) there is no interaction between the particle and fluid; e) the diameter of the suspension column is large compared to the diameter of the particle, i.e. the fluid is of “infinite extent”; f) the particle has reached its terminal velocity; g) the particles are of the same relative density.
Thus, the diameter of a particle is defined in terms of the diameter of a sphere whose behaviour in suspension matches that of the particle. This is the concept of equivalent spherical diameter. It is the principle upon which the expression of the diameter of particles, as derived from sedimentation, is based in this document. Stokes's Law can be written, for the purposes of this document, as in Formula (1):
th=−18ηρ/ ()ρ gd (1) sw p
oSIST ISO/DIS 11277:2025 ISO/DIS 11277:2025(en) where t is the settling time, in seconds, of a particle of diameter d (see below); p η is the dynamic viscosity of water at the test temperature (see Table B.2), in millipascals per second; h is the sampling depth, in centimetres;
ρ is the mean particle density, in megagrams per cubic metre (taken as 2,65 Mg/m ; see note); s ρ is the density of the liquid containing the soil suspension, in megagrams per cubic metre (taken w
as 1,00 Mg/m ; see note);
g is the acceleration due to gravity, in centimetres per second squared (taken as 981 cm/s ); d is the equivalent spherical diameter of the particle of interest, in millimetres. p NOTE 1 It is realized that there are considerable differences between the densities of soil particles, but for the
purposes of this document it is assumed that the mean particle density is that of quartz, i.e. 2,65 Mg/m (Reference [8]), 3 3 as this is the commonest mineral in a very wide range of soils. The density of water is 0,998 2 Mg/m and 0,995 6 Mg/m at 20 °C and 30 °C, respectively (see Reference [6]). Given the effect of the addition of a small amount of dispersant (see
9.3.2), the density of water is taken as 1,000 0 Mg/m over the permitted temperature range of this document (see 9.2.2). Furthermore, for routine use, it is recommended that the sampling times be converted to minutes and/or hours, as appropriate, to lessen the risk of error (see Table 3). Particles within particular size ranges or classes are commonly described as cobbles, gravel, coarse sand, silt, etc. The meaning of such trivial names differs between countries, and in some cases there are no exact translations of such words from one language to another; for example, the Dutch word “zavel” has no equivalent in English. The only fraction for which there appears to be common agreement is clay, which is defined as material of less than 0,002 mm equivalent spherical diameter (References [4]). Such trivial names shall not be used in describing the results of particle size determination according to this document. Phrases such as “... passing a 20 mm aperture sieve ...” or “... less than 0,063 mm equivalent spherical diameter ...” shall be used instead. If trivial names shall be used, for example, to cross-reference to another International or National Standard, then the trivial name should be defined explicitly, so as to remove any doubt as to the meaning intended, e.g. silt (0,063 mm to 0,002 mm equivalent spherical diameter) (see Clause 4). Furthermore, it is common to use the word “texture” to describe the results of particle-size-distribution measurements, e.g. “the particle size of this soil is of clay texture”. This is incorrect as the two concepts are different, and the word “texture” shall not be used in the test report (see Clause 10) to describe the results obtained by the use of this document.
6 Field sampling
The mass of sample taken in the field shall be representative of the particle size distribution, especially if the amount of the larger particles is to be determined reliably. Table 1 gives recommended minimum masses. Table 1 — Mass of soil sample to be taken for sieving Maximum size of material forming > 10 % of the soil Minimum mass of sample to be taken for sieving (given as test sieve aperture, in mm) kg 63 50 50 35 37,5 15 28 6 20 2 14 1 10 0,5
oSIST ISO/DIS 11277:2025 ISO/DIS 11277:2025(en) TTabablele 1 1 ((ccoonnttiinnueuedd)) Maximum size of material forming > 10 % of the soil Minimum mass of sample to be taken for sieving (given as test sieve aperture, in mm) kg 6,3 0,5 5 0,2 2 or smaller 0,1
7 Sample preparation
Samples shall be prepared in accordance with the methods given in ISO 11464. NOTE For many purposes, particle size distribution is determined only for the fraction of the soil passing a 2 mm aperture sieve. In this case, the test sample (9.5) can be taken either according to the procedures in ISO 11464 or from the material passing a 2 mm aperture sieve according to 8.2.
8 Dry sieving (material >2 mm)
8.1 General
The procedure specified in this clause applies to material retained on a 2 mm aperture sieve. Table 2 gives the maximum mass which shall be retained on sieves of different diameters and apertures. If more than this amount of material is retained, then it shall be subdivided appropriately and sieved again. It is common to refer to sieves as having a particular mesh-size or mesh number. These are not the same as the sieve aperture, and the relationship between the various numbers is not immediately obvious. The use of mesh numbers as a measurement of particle size is difficult to justify, and shall not be used in reporting the results of this document.
8.2 Apparatus
8.2.1 Test sieves, with apertures according to ISO 565, and with well-fitting covers and receivers. The full range of sieves appropriate to the largest particle(s) present should be used (see Table 1 and 9.2.3). The apertures chosen shall be stated in the test report (Clause 10). The accuracy of the sieves shall be verified monthly against a set of master sieves kept for this purpose, using an accepted method such as particle reference materials, microscopy, etc. (see Reference [2]) depending on the sieve aperture. Tolerances shall meet the requirements of ISO 3310-1 and ISO 3310-2. Sieves that do not meet these specifications shall be discarded. A record shall be kept of such testing.
Brass sieves are particularly liable to splitting and distortion, and steel sieves are strongly recommended for the larger apertures.
Special care shall be taken to ensure that covers and receivers do not leak. Sieves shall be inspected weekly when in regular use, and on every occasion if used less often. A record shall be kept of such inspections. Round-hole sieves shall not be used.
8.2.2 Balance, capable of weighing to an accuracy of within ±0,5 g. 8.2.3 Mechanical sieve shaker.
It is usually impracticable to sieve mechanically at sieve apertures much greater than 20 mm, unless very heavy-duty equipment is available. Mechanical sieve shaking is essential to sieve efficiency at smaller apertures.
8.2.4 A sieve brush and a stiff brush.
oSIST ISO/DIS 11277:2025 ISO/DIS 11277:2025(en) 8.2.5 Ultrasonic bath, able to provide an acoustic power P (W) level in the range of 5 W to 20 W per litre ac of water (see Annex D), typically operating at a frequency between 37 kHz to 45 kHz.
8.3 Procedure
Weigh the dry test sample, prepared in accordance with ISO 11464, to the nearest 0,5 g (m ). Place the
weighed material on the 20 mm sieve, and by brushing the material gently over the sieve apertures with the stiff brush (to remove any adhering soil), sieve the material. Take care not to detach any fragments from the primary particles. Sieve the retained material on the nest of sieves of selected apertures (8.2.1) and record the amount retained on each sieve to the nearest 0,5 g. Do not overload the sieves (see Table 1) but sieve the material in portions if necessary.
Weigh the material passing the 20 mm aperture sieve (m ), or a suitable portion of it (m ) (see Table 2) 2 3 obtained by an appropriate subsampling method (see Clause 6), and place this on a nest of sieves, the lowermost having an aperture of 2 mm. Shake the sieves mechanically until no further material passes any of the sieves (see Note). Record the mass of material retained on each sieve and the mass passing the 2 mm aperture sieve.
The total mass of the fractions should be within 1 % of m or m , as appropriate. If it is not, then check for 2 3 sieve damage and discard sieves as appropriate (see 8.2.1).
NOTE For practical purposes, it is usual to choose a standard sieve shaking time which gives an acceptable degree of sieving efficiency with a wide range of soil materials. The minimum recommended period is 10 min. Table 2 — Maximum mass of material to be retained on each test sieve at the completion of sieving Test sieve Maximum mass aperture kg Sieve diameter mm mm 450 400 300 200 100 50 10 8,9 4,5 — — 37,5 8 7,1 3,5 — — 28 6 5,3 2,5 — — 20 4 3,6 2 — — 14 3 2,7 1,5 — — 10 2 1,8 1 — — 6,3 1,5 1,3 0,75 — — 5 1 0,9 0,5 — — 3,35 — — 0,3 0,15 2 — — 0,2 0,1 1,18 — — 0,1 0,05 0,6 — — 0,075 0,037 5 0,425 — — 0,075 0,037 5 0,3 — — 0,05 0,025 0,212 — — 0,05 0,025 0,15 — — 0,04 0,02 0,063 — — 0,025 0,012 5
oSIST ISO/DIS 11277:2025 ISO/DIS 11277:2025(en)
8.4 Calculation and expression of results
For the material retained by the 20 mm and larger aperture sieves, calculate the proportion by mass retained by each sieve as a proportion of m . For example (Formula (2)):
Proportionretainedonthem20 msieve=[]mm()20mm / (2)
For the material passing the 20 mm sieve, multiply the mass of material passing each sieve by m /m and 2 3 calculate this as a proportion of m . For example (Formula (3)):
Proportionretainedonthem63,,msieve= mm()63mm []()//mm (3) 23 1 Present the results as a Table showing, to two significant figures, the proportion by mass retained on each sieve and the proportion passing the 2 mm sieve. The data shall also be used to construct a cumulative distribution curve (see Figure 1).
9 Wet sieving and sedimentation (material <2 mm)
9.1 General
This clause specifies the procedure (see Figure 2) for the determination of the particle size distribution of the material passing the 2 mm aperture sieve down to <0,002 mm equivalent spherical diameter (see note). In order to ensure that primary particles, rather than loosely bonded aggregates, are measured, organic matter and salts are removed, especially sparingly soluble salts such as gypsum which would otherwise prevent dispersion and/or promote flocculation of the finer soil particles in suspension (see 9.6), and a dispersing agent is added (9.3.2). These procedures are required in this document, and their omission shall invalidate its application. Sometimes iron oxides and carbonates, especially of calcium and/or magnesium, are also removed. Preferred procedures for the removal of these compounds are given in the note in 9.7. The removal of any compound shall be recorded in the test report (see Clause 10). NOTE 1 Gravitational sedimentation can give a value for the total amount of material <0,002 mm equivalent spherical diameter. However, the method cannot be used to divide this class further with reliability, as particles less than about 0,001 mm equivalent spherical diameter can be kept in suspension almost indefinitely by Brownian motion (see Reference [2]).
9.2 Apparatus
The apparatus specified hereafter is sufficient to deal with one sample. Clearly it is more efficient to work in batches. Experience has shown (see Reference [7]) that one operator can process up to 36 samples in a batch at a time, given sufficient apparatus and space, especially if calculations are dealt with by a computer. 9.2.1 Sampling pipette or sampling needle, of a pattern similar to that shown in Figure 3 with sideways openings, the chief requirement being that the smallest practicable horizontal zone of sedimenting suspension shall be sampled. The pipette shall be of not less than 10 ml volume and shall be held in a frame so that it can be lowered to a fixed depth within a sedimentation tube (see Figure 4). NOTE 1 Experience suggests that a pipette with an upper volume of 50 ml is more than sufficient for most purposes. A 25 ml volume pipette is a convenient compromise for routine analysis, but a smaller volume pipette will be found to be sufficient for soils with down to about 10 % mass fraction of <0,063 mm equivalent spherical diameter. Below this amount, greater precision is likely to be obtained with a pipette of larger volume. NOTE 2 The position of the pipette is adjusted to the new suspension surface after each sampling. NOTE 3 Automated systems can be used, if the results are proven to be equivalent.
...
Contents
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 3.1 diameter of a particle
- 4 Symbols
- 5 Principle
- 6 Field sampling
- 7 Sample preparation
- 8 Dry sieving (material >2 mm)
- 8.1 General
- 8.2 Apparatus
- 8.3 Procedure
- 8.4 Calculation and expression of results
- 9 Wet sieving and sedimentation (material <2 mm)
- 9.1 General
- 9.2 Apparatus
- 9.3 Reagents
- 9.4 Calibrations
- 9.5 Test sample
- 9.6 Destruction of organic matter
- 9.7 Removal of soluble salts and gypsum
- 9.8 Removal of carbonates
- 9.9 Removal of iron oxides
- 9.10 Dispersion
- 9.11 Wet sieving at 0,063 mm
- 9.12 Sedimentation
- 9.13 Calculation of results for fractions <2 mm
- 10 Test report
- Annex A
- Annex B
- Annex C
- Annex D
- Bibliography
Introduction
The physical and chemical behaviour of soils is controlled in part by the amounts of mineral particles of different sizes in the soil. The subject of this document is the quantitative measurement of such amounts (expressed as a proportion or percentage of the total mass of the mineral soil), within stated size classes. The determination of particle size distribution is affected by organic matter, soluble salts, cementing agents (such as iron compounds), relatively insoluble substances such as carbonates and sulfates, or combinations of these. Some soils change their behaviour to such a degree, upon drying, that the particle size distribution of the dried material bears little or no relation to that of the undried material encountered under natural conditions. This is particularly true of soils rich in organic matter, those developed from recent volcanic deposits, some highly weathered tropical soils, and soils often described as “cohesive” (see Reference [4]). Other soils, such as the so-called “sub-plastic” soils of Australia, show little or no tendency to disperse under normal laboratory treatments, despite field evidence of large clay content. The procedures given in this document recognize these kinds of differences between soils from different environments, and the methodology presented is designed to deal with them in a structured manner. Such differences in soil behaviour can be very important, but awareness of them depends usually on local knowledge. Given that the laboratory is commonly distant from the site of the field operation, the information supplied by field teams becomes crucial to the choice of an appropriate laboratory procedure. This choice can be made only if the laboratory is made fully aware of this background information.
FINAL DRAFT International Standard ISO/FDIS 11277:2026(en) Soil quality — Determination of particle size distribution in mineral soil material — Method by sieving and sedimentation WARNING — Persons using this document should be familiar with usual laboratory practice. This document does not purport to address all safety problems, if any, associated with its use. It is the responsibility of the user to establish appropriate safety and health practices and to ensure compliance with any national regulatory conditions.
IMPORTANT — Tests conducted in accordance with this document shall be carried out by suitably trained staff.
1 Scope
This document specifies a basic method of determining the particle size distribution applicable to a wide range of mineral soil materials, including the mineral fraction of organic soils. It also offers procedures to deal with the less common soils mentioned in the introduction. This document has been developed largely for use in the field of environmental science, and its use in geotechnical investigations is something for which professional advice might be required.
A major objective of this document is the determination of enough size fractions to enable the construction of a reliable particle-size-distribution curve.
This document does not apply to the determination of the particle size distribution of the organic components of soil, i.e. the more or less fragile, partially decomposed, remains of plants and animals. It is also realized that the chemical pre-treatments and mechanical handling stages in this document could cause disintegration of weakly cohesive particles that, from field inspection, might be regarded as primary particles, even though such primary particles could be better described as aggregates. If such disintegration is undesirable, then this document is not used for the determination of the particle size distribution of such weakly cohesive materials.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 565, Test sieves — Metal wire cloth, perforated metal plate and electroformed sheet — Nominal sizes of openings ISO 11265, Environmental solid matrices — Determination of the specific electrical conductivity ISO 11464, Soil quality — Pretreatment of samples for physico-chemical analysis ISO 3310-1, Test sieves — Technical requirements and testing — Part 1: Test sieves of metal wire cloth ISO 3310-2, Test sieves — Technical requirements and testing — Part 2: Test sieves of perforated metal plate
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:
- ISO Online browsing platform: available at https:// www .iso .org/ obp
ISO/FDIS 11277:2026(en) - IEC Electropedia: available at https:// www .electropedia .org/
3.1 diameter of a particle
diameter of a sphere whose behaviour in suspension matches that of the particle
4 Symbols
The following symbols are used in this document.
C specific heat of the liquid (4,18 J/g·K for water) P d equivalent spherical diameter of the particle of interest mm p 2 2 g acceleration due to gravity (981 cm/s ) cm/s γ electrical conductivity mS/m
h height of the bulb mm H length from the neck of the bulb to graduation d mm
L distance between the graduation marks on the measuring cylinder mm L’ observed hydrometer reading m mass of solid material in 500 ml of dispersant solution g d m mass of residue g r m sample mass g t m mass of solid in suspension in 500 ml g fx m mass of material from the xth pipette sampling g sx M mass of liquid g η dynamic viscosity of water at the test temperature (as shown in Table B.2) mPa/s P proportion P proportion of material <2 mm in the total soil s P proportion of the fraction <2 mm t P proportion in total soil mass tsm P proportion retained on the 6,3 mm sieve 6,3 P proportion retained on the 16 mm sieve
P proportion retained on the 20 mm sieve
p delivered acoustic power ac 3 3 ρ mean particle density (2,65 Mg/m , see the note in Clause 4); Mg/m s 3 3 ρ density of the suspension liquid (1,00 Mg/m , see the note in Clause 4); Mg/m w t elapsed time s
ISO/FDIS 11277:2026(en) Δt time s ΔT temperature K V calibrated volume of the pipette ml
V volume of the hydrometer bulb ml h V indicated volume of the measuring cylinder between the graduations used in the deter- ml L mination of L z effective depth at which the density of the suspension is measured mm z meniscus correction m
5 Principle
The particle size distribution is determined by a combination of sieving and sedimentation, starting from air-dried soil (see Reference [4]). A method for undried soil is given in Annex A. Particles not passing a 2 mm aperture sieve are determined by dry sieving. Particles passing a 2 mm aperture sieve, but retained on a 0,063 mm aperture sieve, are determined by a combination of wet and dry sieving. Particles passing a 0,063 mm aperture sieve are determined by sedimentation.
NOTE 1 The test sieves are specified as type of metal wire cloth. The pipette method is preferred. As an alternative, the hydrometer method is given in Annex B. A combination of sieving and sedimentation enables the construction of a continuous particle-size-distribution curve. The key points in this procedure are summarized as a flow chart in Figure 2. This document requires that the proportions of fractions separated by sedimentation and sieving be determined from the masses of such fractions obtained by weighing. Other methods of determining the mass of such fractions rely on such things as the interaction of particles with electromagnetic radiation or electrical fields (see Reference [2]). There are often considerable difficulties in relating the values obtained by these different methods for the same sample. It is one of the intentions of this document that close adherence to its details should help minimize interlaboratory variation in the determination of the particle size distribution of mineral soils. Therefore, the proportions of fractions shall be determined only by weighing. If this is not the method used, then conformance with this document cannot be claimed in the test report (see Clause 10). Both the pipette and hydrometer methods assume that the settling of particles in the sedimentation cylinder is in accordance with Stokes’s Law (see References [2], [4] and [7]), and the constraints that this implies, namely:
a) the particles are rigid, smooth spheres; b) the particles settle in laminar flow, i.e. the Reynolds number is less than approximately 0,2; this constraint sets an upper equivalent spherical particle diameter (see below) slightly greater than 0,06 mm for Stokesian settling under gravity (Reference [2]); c) the suspension of particles is sufficiently diluted to ensure that no particle interferes with the settling of any other particle; d) there is no interaction between the particle and fluid; e) the diameter of the suspension column is large compared to the diameter of the particle, i.e. the fluid is of “infinite extent”; f) the particle has reached its terminal velocity; g) the particles are of the same relative density.
ISO/FDIS 11277:2026(en) Thus, the diameter of a particle is defined in terms of the diameter of a sphere whose behaviour in suspension matches that of the particle. This is the concept of equivalent spherical diameter. It is the principle upon which the expression of the diameter of particles, as derived from sedimentation, is based in this document. Stokes’s Law can be written, for the purposes of this document, as in Formula (1):
th18/ gd (1)
sw p
NOTE 2 It is realized that there are considerable differences between the densities of soil particles, but for the
purposes of this document it is assumed that the mean particle density is that of quartz, i.e. 2,65 Mg/m (Reference [8]),
as this is the commonest mineral in a very wide range of soils. The density of water is 0,998 2 Mg/m and 0,995 6 Mg/
m at 20 °C and 30 °C, respectively (see Reference [6]). Given the effect of the addition of a small amount of dispersant
(see 9.3.2), the density of water is taken as 1,000 0 Mg/m over the permitted temperature range of this document (see 9.2.2).
Furthermore, for routine use, it is recommended that the sampling times be converted to minutes or hours, or both, as appropriate, to lessen the risk of error (see Table 3). Particles within particular size ranges or classes are commonly described as cobbles, gravel, coarse sand, silt, etc. The meaning of such trivial names differs between countries, and in some cases, there are no exact translations of such words from one language to another; for example, the Dutch word “zavel” has no equivalent in English. The only fraction for which there appears to be common agreement is clay, which is defined as material of less than 0,002 mm equivalent spherical diameter (References [4]). Such trivial names shall not be used in describing the results of particle size determination according to this document. Phrases such as “... passing a 20 mm aperture sieve ...” or “... less than 0,063 mm equivalent spherical diameter ...” shall be used instead. If trivial names are used, for example, to cross-reference to another International or National Standard, then the trivial name should be defined explicitly, to remove any doubt as to the meaning intended, e.g. silt (0,063 mm to 0,002 mm equivalent spherical diameter) (see Clause 4). Furthermore, it is common to use the word “texture” to describe the results of particle-size-distribution measurements, e.g. “the particle size of this soil is of clay texture”. This is incorrect as the two concepts are different, and the word “texture” shall not be used in the test report (see Clause 10) to describe the results obtained using this document.
6 Field sampling
The mass of sample taken in the field shall be representative of the particle size distribution, especially if the amount of the larger particles is to be determined reliably. Table 1 gives recommended minimum masses. Table 1 — Mass of soil sample to be taken for sieving Maximum size of material forming >10 % of the soil Minimum mass of sample to be taken for sieving (given as test sieve aperture, in mm) kg 63 50 50 35 37,5 15 28 6 20 2 14 1 10 0,5 6,3 0,5 5 0,2 2 or smaller 0,1
ISO/FDIS 11277:2026(en)
7 Sample preparation
Samples shall be prepared in accordance with the methods given in ISO 11464. NOTE For many purposes, particle size distribution is determined only for the fraction of the soil passing a 2 mm aperture sieve. In this case, the test sample (9.5) can be taken either according to the procedures in ISO 11464 or from the material passing a 2 mm aperture sieve according to 8.2.
8 Dry sieving (material >2 mm)
8.1 General
The procedure specified in this clause applies to material retained on a 2 mm aperture sieve. Table 2 gives the maximum mass which shall be retained on sieves of different diameters and apertures. If more than this amount of material is retained, then it shall be subdivided appropriately and sieved again. It is common to refer to sieves as having a particular mesh-size or mesh number. These are not the same as the sieve aperture, and the relationship between the various numbers is not immediately obvious. The use of mesh numbers as a measurement of particle size is difficult to justify and shall not be used in reporting the results of the procedures described in this document.
8.2 Apparatus
8.2.1 Test sieves, with apertures according to ISO 565, and with well-fitting covers and receivers. The full range of sieves appropriate to the largest particle(s) present should be used (see Table 1 and 8.2.3). The apertures chosen shall be stated in the test report (Clause 10). The accuracy of the sieves shall be verified monthly against a set of master sieves kept for this purpose, using an accepted method such as particle reference materials, microscopy, etc. (see Reference [2]) depending on the sieve aperture. Tolerances shall meet the requirements of ISO 3310-1 and ISO 3310-2. Sieves that do not meet these specifications shall be discarded. A record shall be kept of such testing.
Brass sieves are particularly liable to splitting and distortion, and steel sieves are strongly recommended for the larger apertures.
Special care shall be taken to ensure that covers and receivers do not leak. Sieves shall be inspected weekly when in regular use, and on every occasion if used less often. A record shall be kept of such inspections. Round-hole sieves shall not be used.
8.2.2 Balance, capable of weighing to an accuracy of within ±0,5 g. 8.2.3 Mechanical sieve shaker.
It is usually impracticable to sieve mechanically at sieve apertures much greater than 20 mm, unless very heavy-duty equipment is available. Mechanical sieve shaking is essential to sieve efficiency at smaller apertures.
8.2.4 A sieve brush and a stiff brush.
8.2.5 Ultrasonic bath, able to provide an acoustic power p (W) level in the range of 5 W to 20 W per litre ac of water (see Annex D), typically operating at a frequency between 37 kHz to 45 kHz.
8.3 Procedure
Weigh the dry test sample, prepared in accordance with ISO 11464, to the nearest 0,5 g (m ). Place the
weighed material on the 20 mm sieve, and by brushing the material gently over the sieve apertures with the stiff brush (to remove any adhering soil), sieve the material. Take care not to detach any fragments from the
ISO/FDIS 11277:2026(en) primary particles. Sieve the retained material on the nest of sieves of selected apertures (8.2.1) and record the amount retained on each sieve to the nearest 0,5 g. Do not overload the sieves (see Table 1) but sieve the material in portions if necessary.
Weigh the material passing the 20 mm aperture sieve (m ), or a suitable portion of it (m ) (see Table 2) 2 3 obtained by an appropriate subsampling method (see Clause 6), and place this on a nest of sieves, the lowermost having an aperture of 2 mm. Shake the sieves mechanically until no further material passes any of the sieves. Record the mass of material retained on each sieve and the mass passing the 2 mm aperture sieve.
The total mass of the fractions should be within 1 % of m or m , as appropriate. If it is not, then check 2 3 for sieve damage and discard sieves as appropriate (see 8.2.1). For practical purposes, a standard sieve shaking time should be chosen which gives an acceptable degree of sieving efficiency with a wide range of soil materials.
Table 2 — Maximum mass of material to be retained on each test sieve at the completion of sieving Test sieve Maximum mass aperture kg Sieve diameter mm mm 450 400 300 200 100 50 10 8,9 4,5 — — 37,5 8 7,1 3,5 — — 28 6 5,3 2,5 — — 20 4 3,6 2 — — 14 3 2,7 1,5 — — 10 2 1,8 1 — — 6,3 1,5 1,3 0,75 — — 5 1 0,9 0,5 — — 3,35 — — — 0,3 0,15 2 — — — 0,2 0,1 1,18 — — — 0,1 0,05 0,6 — — — 0,075 0,037 5 0,425 — — — 0,075 0,037 5 0,3 — — — 0,05 0,025 0,212 — — — 0,05 0,025 0,15 — — — 0,04 0,02 0,063 — — — 0,025 0,012 5
ISO/FDIS 11277:2026(en)
8.4 Calculation and expression of results
For the material retained by the 20 mm and larger aperture sieves, calculate the proportion by mass retained by each sieve as a proportion of m . For example, as in Formula (2):
Pm20mm /m (2) 20 1 For the material passing the 20 mm sieve, multiply the mass of material passing each sieve by m /m and 2 3 calculate this as a proportion of m . For example, as in Formula (3):
Pm 63,/mm mm /m (3) 63, 23 1 Present the results as a Table showing, to two significant figures, the proportion by mass retained on each sieve and the proportion passing the 2 mm sieve. The data shall also be used to construct a cumulative distribution curve (see Figure 1).
9 Wet sieving and sedimentation (material <2 mm)
9.1 General
This clause specifies the procedure (see Figure 2) for the determination of the particle size distribution of the material passing the 2 mm aperture sieve down to <0,002 mm equivalent spherical diameter (see NOTE). In order to ensure that primary particles, rather than loosely bonded aggregates, are measured, organic matter and salts are removed, especially sparingly soluble salts such as gypsum which would otherwise prevent either dispersion or promote flocculation of the finer soil particles in suspension, or both (see 9.6), and a dispersing agent is added (9.3.2). These procedures are required in this document, and their omission shall invalidate its application. Sometimes iron oxides and carbonates, especially of calcium and/ or magnesium, are also removed. Preferred procedures for the removal of these compounds are given in the notes in 9.7, 9.8 and 9.9. The removal of any compound shall be recorded in the test report (see Clause 10). NOTE Gravitational sedimentation can give a value for the total amount of material <0,002 mm equivalent spherical diameter. However, the method cannot be used to divide this class further with reliability, as particles less than approximately 0,001 mm equivalent spherical diameter can be kept in suspension almost indefinitely by Brownian motion (see Reference [2]).
...
Contents
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 3.1 3.1 Diameter
- 4 Symbols
- 5 Principle
- 6 Field sampling
- 7 Sample preparation
- 8 Dry sieving (material >2 mm)
- 8.1 General
- 8.2 Apparatus
- 8.3 Procedure
- 8.4 Calculation and expression of results
- 9 Wet sieving and sedimentation (material <2 mm)
- 9.1 General
- 9.2 Apparatus
- 9.3 Reagents
- 9.4 Calibrations
- 9.5 Test sample
- 9.6 Destruction of organic matter
- 9.7 Removal of soluble salts and gypsum
- 9.8 Removal of carbonates
- 9.9 Removal of iron oxides
- 9.10 Dispersion
- 9.11 Wet sieving at 0,063 mm
- 9.12 Sedimentation
- 9.13 Calculation of results for fractions <2 mm
- 10 Test report
- Annex A
- Annex B
- Annex C
- Annex D
- Bibliography
Introduction
The physical and chemical behaviour of soils is controlled in part by the amounts of mineral particles of different sizes in the soil. The subject of this document is the quantitative measurement of such amounts (expressed as a proportion or percentage of the total mass of the mineral soil), within stated size classes. The determination of particle size distribution is affected by organic matter, soluble salts, cementing agents (such as iron compounds), relatively insoluble substances such as carbonates and sulfates, or combinations of these. Some soils change their behaviour to such a degree, upon drying, that the particle size distribution of the dried material bears little or no relation to that of the undried material encountered under natural conditions. This is particularly true of soils rich in organic matter, those developed from recent volcanic [4] deposits, some highly weathered tropical soils, and soils often described as “cohesive” (see Reference [4]).). Other soils, such as the so-called “sub-plastic” soils of Australia, show little or no tendency to disperse under normal laboratory treatments, despite field evidence of large clay content. The procedures given in this document recognize these kinds of differences between soils from different environments, and the methodology presented is designed to deal with them in a structured manner. Such differences in soil behaviour can be very important, but awareness of them depends usually on local knowledge. Given that the laboratory is commonly distant from the site of the field operation, the information supplied by field teams becomes crucial to the choice of an appropriate laboratory procedure. This choice can be made only if the laboratory is made fully aware of this background information.
FINAL DRAFT International Standard ISO/FDIS 11277:2026(en)
Soil quality — Determination of particle size distribution in mineral soil material — Method by sieving and sedimentation WARNING — Persons using this document should be familiar with usual laboratory practice. This document does not purport to address all safety problems, if any, associated with its use. It is the responsibility of the user to establish appropriate safety and health practices and to ensure compliance with any national regulatory conditions.
IMPORTANT — — Tests, conducted in accordance with this document, shall be carried out by suitably qualitfiedtrained staff.
1 Scope
This document specifies a basic method of determining the particle size distribution applicable to a wide range of mineral soil materials, including the mineral fraction of organic soils. It also offers procedures to deal with the less common soils mentioned in the introduction. This document has been developed largely for use in the field of environmental science, and its use in geotechnical investigations is something for which professional advice might be required.
A major objective of this document is the determination of enough size fractions to enable the construction of a reliable particle-size-distribution curve.
This document does not apply to the determination of the particle size distribution of the organic components of soil, i.e. the more or less fragile, partially decomposed, remains of plants and animals. It is also realized that the chemical pre-treatments and mechanical handling stages in this document could cause disintegration of weakly cohesive particles that, from field inspection, might be regarded as primary particles, even though such primary particles could be better described as aggregates. If such disintegration is undesirable, then this document is not used for the determination of the particle size distribution of such weakly cohesive materials.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 565, Test sieves — Metal wire cloth, perforated metal plate and electroformed sheet — Nominal sizes of openings ISO 11265, Soil quality Environmental solid matrices — Determination of the specific electrical conductivity ISO 11464, Soil quality — Pretreatment of samples for physico-chemical analysis ISO 3310--1, Test sieves — Technical requirements and testing — Part 1: Test sieves of metal wire cloth ISO 3310--2, Test sieves — Technical requirements and testing — Part 2: Test sieves of perforated metal plate
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
ISO/FDIS 11277:2026(en) ISO and IEC maintain terminology databases for use in standardization at the following addresses:
- — ISO Online browsing platform: available at https://www.iso.org/obp
- — IEC Electropedia: available at https://www.electropedia.org/
3.1 3.1 Diameter
diameter of a particle diameter of a sphere whose behaviour in suspension matches that of the particle
4 Symbols
The following symbols are found throughout the text and, where appropriate, units and quantities are as given below used in this document.
C specific heat of the liquid (4,18 J/g·K for water) P d equivalent spherical diameter of the particle of interest mm p 2 2 g acceleration due to gravity (981 cm/s ) cm/s γ Electricalelectrical conductivity mS/m
h height of the bulb mm H length from the neck of the bulb to graduation d mm
L distance between the graduation marks on the measuring cylinder mm L’ observed hydrometer reading m mass of solid material in 500 ml of dispersant solution g d m mass of residue g r m Samplesample mass g t m mass of solid in suspension in 500 ml g fx m mass of material from the xth pipette sampling g sx M mass of liquid (g) g η dynamic viscosity of water at the test temperature (as shown in Table B.2Table B.2)) mPmPa/s P proportion P delivered acoustic power ac P proportion of material <2 mm in the total soil s P proportion of the fraction <2 mm t P Proportionproportion in total soil mass tsm P Proportionproportion retained on the 6,3 mm sieve 6,3 P Proportionproportion retained on the 16 mm sieve
P Proportionproportion retained on the 20 mm sieve
p delivered acoustic power ac 3 3 ρ mean particle density (2,65 Mg/m , see the note in Clause 4Clause 4);); Mg/m s 3 3 ρ density of the suspension liquid (1,00 Mg/m , see the note in Clause 4Clause 4);); Mg/m w
ISO/FDIS 11277:2026(en) t elapsed time s Δt time s ΔT temperature K V Calibratedcalibrated volume of the pipette ml
V volume of the hydrometer bulb ml h V indicated volume of the measuring cylinder between the graduations used in the ml L determination of L z effective depth at which the density of the suspension is measured mm z meniscus correction m
5 Principle
The particle size distribution is determined by a combination of sieving and sedimentation, starting from airdried soil (see Reference 4[4]).). A method for undried soil is given in Annex AAnnex A.. Particles not passing a 2 mm aperture sieve are determined by dry sieving. Particles passing a 2 mm aperture sieve, but retained on a 0,063 mm aperture sieve, are determined by a combination of wet and dry sieving, whilst particles. Particles passing a 0,063 mm aperture sieve are determined by sedimentation. Note NOTE 1 The test sieves are specified as typtype of metal wire cloth. The pipette method is preferred. As an alternative, the hydrometer method is given in Annex BAnnex B.. A combination of sieving and sedimentation enables the construction of a continuous particle-size-distribution curve.
The key points in this procedure are summarized as a flow chart in Figure 2Figure 2.. This document requires that the proportions of fractions separated by sedimentation and sieving be determined from the masses of such fractions obtained by weighing. Other methods of determining the mass of such fractions rely on such things as the interaction of particles with electromagnetic radiation or electrical fields (see Reference 2[2]).). There are often considerable difficulties in relating the values obtained by these different methods for the same sample. It is one of the intentions of this document that close adherence to its details should help minimize interlaboratory variation in the determination of the particle size distribution of mineral soils. Therefore, the proportions of fractions shall be determined only by weighing. If this is not the method used, then conformance with this document cannot be claimed in the test report (see Clause 10Clause 10).). Both the pipette and hydrometer methods assume that the settling of particles in the sedimentation cylinder is in accordance with Stokes'sStokes’s Law (see References [2], [4[2], [4]] and [7[7]),]), and the constraints that this implies, namely:
a) a) the particles are rigid, smooth spheres; b) b) the particles settle in laminar flow, i.e. the Reynolds Numbernumber is less than aboutapproximately 0,2; this constraint sets an upper equivalent spherical particle diameter (see below) [2] slightly greater than 0,06 mm for Stokesian settling under gravity (Reference [2]);); c) c) the suspension of particles is sufficiently dilutediluted to ensure that no particle interferes with the settling of any other particle; d) d) there is no interaction between the particle and fluid; e) e) the diameter of the suspension column is large compared to the diameter of the particle, i.e. the fluid is of “infinite extent”;
ISO/FDIS 11277:2026(en) f) f) the particle has reached its terminal velocity; g) g) the particles are of the same relative density.
Thus, the diameter of a particle is defined in terms of the diameter of a sphere whose behaviour in suspension matches that of the particle. This is the concept of equivalent spherical diameter. It is the principle upon which the expression of the diameter of particles, as derived from sedimentation, is based in this document. Stokes'sStokes’s Law can be written, for the purposes of this document, as in Formula (1)Formula (1)::
(1)
𝑡𝑡 = 18𝜂𝜂ℎ/[(𝜌𝜌 −𝜌𝜌 )𝑔𝑔𝑑𝑑 ] (1) 𝑠𝑠 w p NOTE 2 It is realized that there are considerable differences between the densities of soil particles, but for the
purposes of this document it is assumed that the mean particle density is that of quartz, i.e. 2,65 Mg/m [8] 3 (Reference [8]),), as this is the commonest mineral in a very wide range of soils. The density of water is 0,998 2 Mg/m 3 [6] and 0,995 6 Mg/m at 20 °C and 30 °C, respectively (see Reference [6]).). Given the effect of the addition of a small
amount of dispersant (see 9.3.29.3.2),), the density of water is taken as 1,000 0 Mg/m over the permitted temperature range of this document (see 9.2.29.2.2).).
Furthermore, for routine use, it is recommended that the sampling times be converted to minutes or hours, or both, as appropriate, to lessen the risk of error (see Table 3Table 3).). Particles within particular size ranges or classes are commonly described as cobbles, gravel, coarse sand, silt, etc. The meaning of such trivial names differs between countries, and in some cases, there are no exact translations of such words from one language to another; for example, the Dutch word “zavel” has no equivalent in English. The only fraction for which there appears to be common agreement is clay, which is [4] defined as material of less than 0,002 mm equivalent spherical diameter (References [4]).). Such trivial names shall not be used in describing the results of particle size determination according to this document. Phrases such as “... passing a 20 mm aperture sieve ...” or “... less than 0,063 mm equivalent spherical diameter ...” shall be used instead. If trivial names shall beare used, for example, to cross-reference to another International or National Standard, then the trivial name should be defined explicitly, to remove any doubt as to the meaning intended, e.g. silt (0,063 mm to 0,002 mm equivalent spherical diameter) (see Clause 4Clause 4).). Furthermore, it is common to use the word “texture” to describe the results of particlesize-distribution measurements, e.g. “the particle size of this soil is of clay texture”. This is incorrect as the two concepts are different, and the word “texture” shall not be used in the test report (see Clause 10Clause 10)) to describe the results obtained using this document.
6 Field sampling
The mass of sample taken in the field shall be representative of the particle size distribution, especially if the amount of the larger particles is to be determined reliably. Table 1Table 1 gives recommended minimum masses.
Table 1 — Mass of soil sample to be taken for sieving Maximum size of material forming >10 % of the soil Minimum mass of sample to be taken for sieving (given as test sieve aperture, in mm) kg 63 50 50 35 37,5 15 28 6
ISO/FDIS 11277:2026(en) Maximum size of material forming >10 % of the soil Minimum mass of sample to be taken for sieving (given as test sieve aperture, in mm) kg 20 2 14 1 10 0,5 6,3 0,5 5 0,2 2 or smaller 0,1
7 Sample preparation
Samples shall be prepared in accordance with the methods given in ISO 11464. NOTE For many purposes, particle size distribution is determined only for the fraction of the soil passing a 2 mm aperture sieve. In this case, the test sample (9.5(9.5)) can be taken either according to the procedures in ISO 11464 or from the material passing a 2 mm aperture sieve according to 8.28.2..
8 Dry sieving (material >2 mm)
8.1 General
The procedure specified in this clause applies to material retained on a 2 mm aperture sieve. Table 2Table 2 gives the maximum mass which shall be retained on sieves of different diameters and apertures. If more than this amount of material is retained, then it shall be subdivided appropriately and sieved again. It is common to refer to sieves as having a particular mesh-size or mesh number. These are not the same as the sieve aperture, and the relationship between the various numbers is not immediately obvious. The use of mesh numbers as a measurement of particle size is difficult to justify and shall not be used in reporting the results of the procedures described in this document.
8.2 Apparatus
8.2.1 8.2.1 Test sieves, with apertures according to ISO 565, and with well-fitting covers and receivers. The full range of sieves appropriate to the largest particle(s) present should be used (see Table 1Table 1 and 8.2.39.2.3).). The apertures chosen shall be stated in the test report (Clause 10(Clause 10).). The accuracy of the sieves shall be verified monthly against a set of master sieves kept for this purpose, using an accepted [2] method such as particle reference materials, microscopy, etc. (see Reference [2])) depending on the sieve aperture. Tolerances shall meet the requirements of ISO 3310--1 and ISO 3310--2. Sieves that do not meet these specifications shall be discarded. A record shall be kept of such testing. Brass sieves are particularly liable to splitting and distortion, and steel sieves are strongly recommended for the larger apertures.
Special care shall be taken to ensure that covers and receivers do not leak. Sieves shall be inspected weekly when in regular use, and on every occasion if used less often. A record shall be kept of such inspections. Roundhole sieves shall not be used. 8.2.2 8.2.2 Balance, capable of weighing to an accuracy of within ±0,5 g. 8.2.3 8.2.3 Mechanical sieve shaker.
ISO/FDIS 11277:2026(en) It is usually impracticable to sieve mechanically at sieve apertures much greater than 20 mm, unless very heavy-duty equipment is available. Mechanical sieve shaking is essential to sieve efficiency at smaller apertures.
8.2.4 8.2.4 A sieve brush and a stiff brush.
8.2.5 8.2.5 Ultrasonic bath, able to provide an acoustic power P p (W) level in the range of 5 W to 20 W ac ac per litre of water (see Annex DAnnex D),), typically operating at a frequency between 37 kHz to 45 kHz.
8.3 Procedure
Weigh the dry test sample, prepared in accordance with ISO 11464, to the nearest 0,5 g (m ). Place the
weighed material on the 20 mm sieve, and by brushing the material gently over the sieve apertures with the stiff brush (to remove any adhering soil), sieve the material. Take care not to detach any fragments from the primary particles. Sieve the retained material on the nest of sieves of selected apertures (8.2.1(8.2.1)) and record the amount retained on each sieve to the nearest 0,5 g. Do not overload the sieves (see Table 1Table 1)) but sieve the material in portions if necessary.
Weigh the material passing the 20 mm aperture sieve (m ), or a suitable portion of it (m ) (see 2 3 Table 2Table 2)) obtained by an appropriate subsampling method (see Clause 6Clause 6),), and place this on a nest of sieves, the lowermost having an aperture of 2 mm. Shake the sieves mechanically until no further material passes any of the sieves (see Note).. Record the mass of material retained on each sieve and the mass passing the 2 mm aperture sieve.
The total mass of the fractions should be within 1 % of m or m , as appropriate. If it is not, then check for 2 3 sieve damage and discard sieves as appropriate (see 8.2.18.2.1). ). For practical purposes, a standard sieve shaking time should be chosen which gives an acceptable degree of sieving efficiency with a wide range of soil materials.
Table 2 — Maximum mass of material to be retained on each test sieve at the completion of sieving Test sieve Maximum mass aperture kg Sieve diameter mm mm 450 400 300 200 100 50 10 8,9 4,5 — — 37,5 8 7,1 3,5 — — 28 6 5,3 2,5 — — 20 4 3,6 2 — — 14 3 2,7 1,5 — — 10 2 1,8 1 — — 6,3 1,5 1,3 0,75 — — 5 1 0,9 0,5 — — 3,35 — — — 0,3 0,15 2 — — — 0,2 0,1 1,18 — — — 0,1 0,05 0,6 — — — 0,075 0,037 5
ISO/FDIS 11277:2026(en) Test sieve Maximum mass aperture kg Sieve diameter mm mm 450 400 300 200 100 0,425 — — — 0,075 0,037 5 0,3 — — — 0,05 0,025 0,212 — — — 0,05 0,025 0,15 — — — 0,04 0,02 0,063 — — — 0,025 0,012 5
8.4 Calculation and expression of results
For the material retained by the 20 mm and larger aperture sieves, calculate the proportion by mass retained by each sieve as a proportion of m . For example, as in Formula (2) (Formula (2))::
𝑃𝑃 = [𝑚𝑚(20 mm)]/𝑚𝑚 (2) 20 1 For the material passing the 20 mm sieve, multiply the mass of material passing each sieve by m /m and 2 3 calculate this as a proportion of m . For example, as in Formula (3) (Formula (3))::
(3)
𝑃𝑃 =𝑚𝑚(6,3 mm)[(𝑚𝑚 𝑚𝑚 ) 𝑚𝑚 ] 6,3 2 3 1 (3) Present the results as a Table showing, to two significant figures, the proportion by mass retained on each sieve and the proportion passing the 2 mm sieve. The data shall also be used to construct a cumulative distribution curve (see Figure 1Figure 1).).
9 Wet sieving and sedimentation (material <2 mm)
9.1 General
This clause specifies the procedure (see Figure 2Figure 2)) for the determination of the particle size distribution of the material passing the 2 mm aperture sieve down to <0,002 mm equivalent spherical diameter (see noteNOTE). In order to ensure that primary particles, rather than loosely bonded aggregates, are measured, organic matter and salts are removed, especially sparingly soluble salts such as gypsum which would otherwise prevent either dispersion or promote flocculation of the finer soil particles in suspension, or both (see 9.69.6),), and a dispersing agent is added (9.3.2(9.3.2).). These procedures are required in this document, and their omission shall invalidate its application. Sometimes iron oxides and carbonates, especially of calcium and/or magnesium, are also removed. Preferred procedures for the removal of these compounds are given in the notes in 9.79.7, 9.8, 9.8 and 9.99.9.. The removal of any compound shall be recorded in the test report (see Clause 10Clause 10).).
...