Abstract

ISO 8536-5:2004 specifies requirements for types of single-use, gravity feed burette infusion sets of 50 ml, 100 ml and 150 ml nominal capacity for medical use in order to ensure compatibility of use with containers for infusion solutions and intravenous equipment.
ISO 8536-5:2004 also provides guidance on specifications relating to the quality and performance of materials.
In some countries, national pharmacopoeia or other national regulations are legally binding and take precedence over ISO 8536-5:2004.

Status
Published
Publication Date
15-Apr-2013
Technical Committee
VAZ - Healthcare
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
05-Mar-2013
Due Date
10-May-2013
Completion Date
16-Apr-2013

Buy Documents

Standard

SIST EN ISO 8536-5:2013

English language (13 pages)
Preview
Preview
e-Library read for
×1 day

SIST EN ISO 8536-5:2013 is the Slovenian standard identical to EN ISO 8536-5:2013, which adopts ISO 8536-5:2004. It specifies requirements for burette infusion sets for single use, gravity feed, used in medical infusion equipment, mainly for 50 ml, 100 ml and 150 ml nominal capacities.

What does SIST EN ISO 8536-5:2013 specify?

SIST EN ISO 8536-5:2013 sets requirements for single-use, gravity-feed burette infusion sets so they work compatibly with infusion-solution containers and intravenous equipment. It also gives guidance on material quality and performance for the parts used in these sets.

The standard is organized into a short technical core:

  • Clause 1 Scope
  • Clause 2 Normative references
  • Clause 3 General requirements
  • Clause 4 Designation
  • Clause 5 Materials
  • Clause 6 Physical requirements
  • Clauses 7 to 10 Chemical requirements, Biological requirements, Labelling, and Packaging
  • Informative Annex ZA on the link to EU medical-device requirements
AnnexWhat it covers
ZARelationship between this European Standard and the Essential Requirements of EU Directive 93/42/EEC on Medical Devices

What are the key requirements of SIST EN ISO 8536-5:2013?

SIST EN ISO 8536-5:2013 focuses on the design, materials, and basic performance features that affect safe use and compatibility in infusion practice.

  • Clause 3.1 says the component names are given in Figure 1, and it shows example configurations of a burette infusion set. In practice, this gives manufacturers and inspectors a common vocabulary for the parts they are specifying or checking.
  • Clause 3.2 requires protective caps to keep the internal parts sterile until use. This matters because the set is used directly in a medical fluid path.
  • Clause 3.3 requires any separate air-inlet device to comply with ISO 8536-4. That means the air entry function is not free to vary if a separate device is used.
  • Clause 4 defines the designation format: burette set, ISO 8536-5 reference, nominal capacity in millilitres, and gravity-feed indication. This is what appears in ordering, labelling, and procurement documents.
  • Clause 5 requires the materials for the set and its components to meet the physical requirements in Clause 6, and any parts that contact solutions to meet Clauses 7 and 8 as well. In practice, material choice is not only a manufacturing issue - it also affects contact with infusion fluids.
  • Clause 6.2 requires the burette to be rigid or semi-rigid plastics, to allow visual observation of fluid, to have filtered air venting above the top graduation mark, and to be able to act as a separate self-vented reservoir. These features affect filling, reading, and controlled delivery.
  • Clause 6.4 controls the graduated scale: the scale intervals, line quality, numbering, and the zero mark position are all specified. This is important because the user must be able to read delivered volume accurately.
  • Clauses 7 to 10 point back to ISO 8536-4 for chemical, biological, labelling, and packaging requirements. That keeps the broader safety and information requirements aligned with the companion gravity-feed infusion-set standard.

What terms does SIST EN ISO 8536-5:2013 define?

  • Burette infusion set - A single-use infusion set with a graduated burette chamber used to control and measure fluid delivery by gravity.
  • Gravity feed - Delivery of infusion fluid by gravity rather than by a pump or pressure source.
  • Nominal capacity - The stated burette volume used to identify the set, such as 50 ml, 100 ml, or 150 ml.
  • Protective cap - A cap that keeps the internal parts of the set protected and sterile before use.
  • Filtered air-venting capability - An air inlet that includes filtration so the burette can vent air while controlling contamination risk.
  • Self-vented reservoir - A reservoir arrangement that can receive fluid and then be closed off while maintaining its own venting function.
  • BS - The designation abbreviation for burette set used in Clause 4.
  • G - The designation abbreviation for gravity feed used in Clause 4.

Who uses SIST EN ISO 8536-5:2013?

SIST EN ISO 8536-5:2013 is used by manufacturers of medical infusion equipment, component suppliers, and quality teams that specify or verify burette infusion sets. It is also useful for purchasers, inspection staff, and test laboratories that need a common technical basis for compatibility, material checks, and product designation.

The standard sits in the medical-device field, especially transfusion, infusion and injection equipment. That makes it relevant wherever single-use gravity-feed infusion sets are designed, sourced, or assessed.

What changed in SIST EN ISO 8536-5:2013 from the previous edition?

SIST EN ISO 8536-5:2013 supersedes EN ISO 8536-5:2011. The underlying ISO text is the second edition of ISO 8536-5 and it cancels and replaces ISO 8536-5:1992 as a technically revised edition.

Which standards are used with SIST EN ISO 8536-5:2013?

  • ISO 8536-4 - This is the normative reference used for general physical requirements where applicable, and for the chemical, biological, labelling, and packaging requirements that Clauses 7 to 10 adopt by reference.
  • EN ISO 10993 series - Annex ZA mentions this series as a route for biological evaluation when a manufacturer chooses to apply it in support of EU medical-device conformity.

What does the SIST EN ISO 8536-5:2013 document contain?

The document includes one example figure of a burette set configuration and one figure showing typical graduated scales. Table 1 sets the scale-interval rules and the tolerance on graduated capacity for the burette.

Annex ZA gives a clause-by-clause mapping to EU Directive 93/42/EEC, which is useful for regulatory assessment and conformity work. The rest of the text is short and practical, with requirements aimed at design, identification, material selection, and reading the delivered volume correctly.

Relations

Effective Date
01-May-2013
Effective Date
06-Dec-2023

Buy Documents

Standard

SIST EN ISO 8536-5:2013

English language (13 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

BSI Group

BSI (British Standards Institution) is the business standards company that helps organizations make excellence a habit.

UKAS United Kingdom Verified

TÜV Rheinland

TÜV Rheinland is a leading international provider of technical services.

DAKKS Germany Verified

TÜV SÜD

TÜV SÜD is a trusted partner of choice for safety, security and sustainability solutions.

DAKKS Germany Verified

Sponsored listings

Frequently Asked Questions

SIST EN ISO 8536-5:2013 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Infusion equipment for medical use - Part 5: Burette infusion sets for single use, gravity feed (ISO 8536-5:2004)". This standard covers: ISO 8536-5:2004 specifies requirements for types of single-use, gravity feed burette infusion sets of 50 ml, 100 ml and 150 ml nominal capacity for medical use in order to ensure compatibility of use with containers for infusion solutions and intravenous equipment. ISO 8536-5:2004 also provides guidance on specifications relating to the quality and performance of materials. In some countries, national pharmacopoeia or other national regulations are legally binding and take precedence over ISO 8536-5:2004.

ISO 8536-5:2004 specifies requirements for types of single-use, gravity feed burette infusion sets of 50 ml, 100 ml and 150 ml nominal capacity for medical use in order to ensure compatibility of use with containers for infusion solutions and intravenous equipment. ISO 8536-5:2004 also provides guidance on specifications relating to the quality and performance of materials. In some countries, national pharmacopoeia or other national regulations are legally binding and take precedence over ISO 8536-5:2004.

SIST EN ISO 8536-5:2013 is classified under the following ICS (International Classification for Standards) categories: 11.040.20 - Transfusion, infusion and injection equipment. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN ISO 8536-5:2013 has the following relationships with other standards: It is inter standard links to SIST EN ISO 8536-5:2012, kSIST FprEN ISO 8536-5:2026. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

SIST EN ISO 8536-5:2013 is associated with the following European legislation: EU Directives/Regulations: 93/42/EEC; Standardization Mandates: M/023. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

SIST EN ISO 8536-5:2013 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • 1 Scope
  • 2 Normative references
  • 3 General requirements
  • 3 ON/OFF clamp 11 tubing
  • 4 Designation
  • 5 Materials
  • 6 Physical requirements
  • 6.1 General
  • 6.2 Design
  • 6.3 Volume of burette
  • 6.4 Graduated scale
  • 7 Chemical requirements
  • 8 Biological requirements
  • 9 Labelling
  • 10 Packaging

1 Scope

This part of ISO 8536 specifies requirements for types of single-use, gravity feed burette infusion sets of 50 ml, 100 ml and 150 ml nominal capacity for medical use in order to ensure compatibility of use with containers for infusion solutions and intravenous equipment.

This part of ISO 8536 also provides guidance on specifications relating to the quality and performance of materials used in infusion sets.

NOTE In some countries, national pharmacopoeia or other national regulations are legally binding and take precedence over this part of ISO 8536.

2 Normative references

The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.

ISO 8536-4, Infusion equipment for medical use — Part 4: Infusion sets for single use, gravity feed

3 General requirements

3.1 The nomenclature to be used for components of burette infusion sets is given in Figure 1. Figure 1 illustrate examples of the configuration of burette infusion sets; other configurations may be used provided they lead to the same results.

3.2 The burette infusion set shall be provided with protective caps to maintain sterility of the internal parts of the set until the set is used.

3.3 If a separate air-inlet device is used, it shall comply with ISO 8536-4.

SIST EN ISO 8536-5:2013 ISO 8536-5:2004(E)

Key 1 protective cap of the closure-piercing device 9 drip tube a c 2 closure-piercing device 10 fluid filter

...