SIST EN 60068-2-30:2006
(Main)Environmental testing -- Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
Environmental testing -- Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
This part of IEC 60068 determines the suitability of components, equipment or other articles for use, transportation and storage under conditions of high humidity – combined with cyclic temperature changes and, in general, producing condensation on the surface of the specimen. If the test is being used to verify the performance of a specimen whilst it is being transported or stored in packaging then the packaging will normally be fitted when the test conditions are being applied. For small, low mass specimens, it may be difficult to produce condensation on the surface of the specimen using this procedure; users should consider the use of an alternative procedure such as that given to IEC 60068-2-38.
Umgebungseinflüsse -- Teil 2-30: Prüfverfahren - Prüfung Db: Feuchte Wärme, zyklisch (12 + 12 Stunden)
Essais d'environnement -- Partie 2-30: Essais - Essai Db: Essai cyclique de chaleur humide (cycle de 12 h + 12 h)
Détermine, par essai, l'aptitude des composants, des matériels ou de tous autres articles destinés à être utilisés, transportés ou stockés dans des conditions d'humidité relative élevée combinées avec des variations cycliques de température et, en général, avec formation de condensation à la surface des spécimens. Si l'essai est utilisé pour vérifier la performance d'un spécimen lors de son transport ou de son stockage dans son emballage, alors l'emballage sera bien ajusté lorsque les conditions d'essais sont appliquées. Pour les petits spécimens, de faible masse, il peut être difficile de produire de la condensation à la surface du spécimen soumis à ce mode opératoire ; il est recommandé que les utilisateurs envisagent l'utilisation d'un mode opératoire alternatif tel qu'indiqué dans la CEI 60068-2-38. Les modifications principales par rapport à l'édition précédente sont les suivantes: - modifications éditoriales, - ajout de références normatives, - ajout de lignes directrices pour les tolérances de température, - prolongation de la période de reprise. A le statut d'une publication fondamentale de sécurité, conformément au Guide CEI 104.
Okoljski preskusi - 2-30. del: Preskusi - Preskus Db: Vlažna toplota, ciklična (12 + 12-urni cikel) (IEC 60068-2-30:2005)
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 60068-2-30:2006
01-februar-2006
1DGRPHãþD
SIST EN 60068-2-30:2001
2NROMVNLSUHVNXVLGHO3UHVNXVL3UHVNXV'E9ODåQDWRSORWDFLNOLþQD
XUQLFLNHO,(&
Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
Umgebungseinflüsse - Teil 2-30: Prüfverfahren - Prüfung Db: Feuchte Wärme, zyklisch
(12 + 12 Stunden)
Essais d'environnement - Partie 2-30: Essais - Essai Db: Essai cyclique de chaleur
humide (cycle de 12 h + 12 h)
Ta slovenski standard je istoveten z: EN 60068-2-30:2005
ICS:
19.040
SIST EN 60068-2-30:2006 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
EUROPEAN STANDARD EN 60068-2-30
NORME EUROPÉENNE
EUROPÄISCHE NORM December 2005
ICS 19.040 Supersedes EN 60068-2-30:1999
English version
Environmental testing
Part 2-30: Tests –
Test Db: Damp heat, cyclic (12 h + 12 h cycle)
(IEC 60068-2-30:2005)
Essais d'environnement Umgebungseinflüsse
Partie 2-30: Essais – Teil 2-30: Prüfverfahren –
Essai Db: Essai cyclique de chaleur Prüfung Db: Feuchte Wärme, zyklisch
humide (cycle de 12 h + 12 h) (12 + 12 Stunden)
(CEI 60068-2-30:2005) (IEC 60068-2-30:2005)
This European Standard was approved by CENELEC on 2005-11-01. CENELEC members are bound to
comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and
notified to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, Czech
Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden,
Switzerland and United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels
© 2005 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 60068-2-30:2005 E
---------------------- Page: 2 ----------------------
EN 60068-2-30:2005 - 2 -
Foreword
The text of document 104/369/FDIS, future edition 3 of IEC 60068-2-30, prepared by IEC TC 104,
Environmental conditions, classification and methods of test, was submitted to the IEC-CENELEC
parallel vote and was approved by CENELEC as EN 60068-2-30 on 2005-11-01.
This European Standard supersedes EN 60068-2-30:1999.
The main changes with respect to EN 60068-2-30:1999 are:
– editorial changes,
– addition of normative references,
– addition of guidance for temperature tolerances,
– period for recovery has been extended.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2006-08-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2008-11-01
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of the International Standard IEC 60068-2-30:2005 was approved by CENELEC as a
European Standard without any modification.
__________
---------------------- Page: 3 ----------------------
- 3 - EN 60068-2-30:2005
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
NOTE Where an international publication has been modified by common modifications, indicated by (mod), the relevant
EN/HD applies.
Publication Year Title EN/HD Year
1) 2)
IEC 60068-2-38 - Environmental testing EN 60068-2-38 1999
Part 2: Tests - Test Z/AD: Composite
temperature/humidity cyclic test
1) 2)
IEC 60068-3-6 - Part 3-6: Supporting documentation and EN 60068-3-6 2002
guidance - Confirmation of the
performance of temperature/humidity
chambers
3)
IEC 60068-1 1988 Part 1: General and guidance EN 60068-1 1994
1) 2)
IEC 60068-5-2 - Part 5: Guide to drafting of test methods - EN 60068-5-2 1999
Terms and definitions
1)
Undated reference.
2)
Valid edition at date of issue.
3)
EN 60068-1 includes corrigendum October 1988 + A1:1992 to IEC 60068-1.
---------------------- Page: 4 ----------------------
IEC 60068-2-30
Edition 3.0 2005-08
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
BASIC SAFETY PUBLICATION
PUBLICATION FONDAMENTALE DE SÉCURITÉ
Environmental testing –
Part 2-30: Tests – Test Db: Damp heat, cyclic (12 + 12 h cycle)
Essais d'environnement –
Partie 2-30: Essais – Essai Db: Essai cyclique de chaleur humide
(cycle de 12 h + 12 h)
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
N
CODE PRIX
ICS 19.040 ISBN 2-8318-8144-7
---------------------- Page: 5 ----------------------
60068-2-30 IEC:2005 – 3 – – 2 – 60068-2-30 © IEC:2005
CONTENTS
FOREWORD.3
Scope.5
1
2 Normative references.5
3 General description.5
4 Testing chamber – Construction requirements.6
5 Severities .6
6 Initial measurements.7
7 Conditioning .7
8 Intermediate measurements.8
9 Recovery .8
10 Final measurements .9
11 Information to be given in the relevant specification.9
Annex A (informative) Selection of variant for the temperature-fall period – Guidance .14
Figure 1 – Test Db – Stabilizing period .10
Figure 2 – Test Db – Test cycle – Variants 1 and 2 .12
Figure 3 – Test Db – Recovery at controlled conditions.13
---------------------- Page: 6 ----------------------
60068-2-30 © IEC:200560068-2-30 IEC:2005 – 5 – – 3 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
___________
ENVIRONMENTAL TESTING –
Part 2-30: Tests – Test Db :
Damp heat, cyclic (12 h + 12 h cycle)
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 60068-2-30 has been prepared by IEC technical committee 104:
Environmental conditions, classification and methods of test.
This third edition cancels and replaces the second edition (1980) and its amendment 1 (1985),
and constitutes a technical revision.
The main changes with respect to the previous edition are listed below:
– editorial changes,
– addition of normative references,
– addition of guidance for temperature tolerances,
– period for recovery has been extended.
---------------------- Page: 7 ----------------------
– 4 – 60068-2-30 © IEC:2005
The text of this standard is based on the following documents:
FDIS Report on voting
104/369/FDIS 104/374/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
It has the status of a basic safety publication in accordance with IEC Guide 104.
This standard forms Part 2-30 of IEC 60068 which consists of the following major parts, under
the general title Environmental testing:
Part 1: General and guidance;
Part 2: Tests;
Part 3: Supporting documentation and guidance;
Part 4: Information for specification writers;
Part 5: Guide to drafting of test methods.
The committee has decided that the contents of this publication will remain unchanged until the
maintenance result date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
---------------------- Page: 8 ----------------------
60068-2-30 © IEC:200560068-2-30 IEC:2005 – 9 – – 5 –
ENVIRONMENTAL TESTING –
Part 2-30: Tests – Test Db:
Damp heat, cyclic (12 h + 12 h cycle)
1 Scope
This part of IEC 60068 determines the suitability of components, equipment or other articles for
use, transportation and storage under conditions of high humidity – combined with cyclic
temperature changes and, in general, producing condensation on the surface of the specimen.
If the test is being used to verify the performance of a specimen whilst it is being transported or
stored in packaging then the packaging will normally be fitted when the test conditions are
being applied.
For small, low mass specimens, it may be difficult to produce condensation on the surface of
the specimen using this procedure; users should consider the use of an alternative procedure
such as that given to IEC 60068-2-38.
2 Normative references
The following referenced documents are indispensable for the application of this document. For
dated references, only the edition cited applies. For undated references, the latest edition of
the referenced document (including any amendments) applies.
IEC 60068-2-38, Environmental testing – Part 2-38: Tests – Test Z/AD: Composite
temperature/humidity cyclic test
IEC 60068-3-6, Environmental testing – Part 3-
...
104/330/CDV
COMMITTEE DRAFT FOR VOTE (CDV)
PROJET DE COMITÉ POUR VOTE (CDV)
Project number IEC 60068-2-30, Ed 3.0
Numéro de projet
IEC/TC or SC: Date of circulation Closing date for voting (Voting
104
Date de diffusion mandatory for P-members)
CEI/CE ou SC:
Date de clôture du vote (Vote
2004-02-13
obligatoire pour les membres (P))
2004-07-16
Titre du CE/SC: Conditions, classification et essais TC/SC Title: Environmental conditions,
d’environnement classification and methods of test
Secretary: Alf Olsson, Sweden
Secrétaire:
Also of interest to the following committees Supersedes document
Intéresse également les comités suivants Remplace le document
104/235/CD and 104/283/CC
Functions concerned
Fonctions concernées
Safety EMC Environment Quality assurance
Sécurité
CEM Environnement Assurance qualité
CE DOCUMENT EST TOUJOURS À L'ÉTUDE ET SUSCEPTIBLE DE THIS DOCUMENT IS STILL UNDER STUDY AND SUBJECT TO CHANGE. IT
MODIFICATION. IL NE PEUT SERVIR DE RÉFÉRENCE. SHOULD NOT BE USED FOR REFERENCE PURPOSES.
LES RÉCIPIENDAIRES DU PRÉSENT DOCUMENT SONT INVITÉS À RECIPIENTS OF THIS DOCUMENT ARE INVITED TO SUBMIT, WITH THEIR
PRÉSENTER, AVEC LEURS OBSERVATIONS, LA NOTIFICATION DES COMMENTS, NOTIFICATION OF ANY RELEVANT PATENT RIGHTS OF
DROITS DE PROPRIÉTÉ DONT ILS AURAIENT ÉVENTUELLEMENT WHICH THEY ARE AWARE AND TO PROVIDE SUPPORTING
CONNAISSANCE ET À FOURNIR UNE DOCUMENTATION EXPLICATIVE. DOCUMENTATION.
Titre : Title :
CEI 60068-2-30 Ed.3 : Essais d’environnement – IEC 60068-2-30 Ed.3: Environmental testing –
Partie 2-30: Essais – Essai Db et guide: Essai Part 2-30: Tests – Test Db and guidance: Damp
cyclique de chaleur humide (cycle de 12 + 12 heat, cyclic (12 + 12-hour cycle)
heures)
Note d'introduction Introductory note
This proposal includes the comments made by
Ce projet inclut les commentaires effectués par
TC 104 WG1 in their list of differences when
le TC 104 WG1 dans sa liste de différence, lors
preparing IEC 60721-4 series.
de la préparation de la série CEI 60721-4.
ATTENTION ATTENTION
CDV soumis en parallèle au vote (CEI) Parallel IEC CDV/CENELEC Enquiry
et à l’enquête (CENELEC)
Copyright © 2004 International Electrotechnical Commission, IEC. All rights reserved. It is
permitted to download this electronic file, to make a copy and to print out the content for the sole
purpose of preparing National Committee positions. You may not copy or "mirror" the file or
printed version of the document, or any part of it, for any other purpose without permission in
writing from IEC.
FORM CDV (IEC)
2002-08-09
---------------------- Page: 1 ----------------------
60068-2-30 © IEC – 2 – 104/330/CDV
CONTENTS
Page
FOREWORD . 3
PREFACE. 3
Clause
1 Scope. 4
2 General description. 4
3 Testing chamber. 4
4 Severities. 5
5 Initial measurements. 5
6 Conditioning. 5
7 Intermediate measurements.6
8 Recovery. 6
9 Final measurements. 7
10 Information to be given in the relevant specification. 7
Figures . 10
Annex A – Guidance . 14
---------------------- Page: 2 ----------------------
60068-2-30 © IEC – 3 – 104/330/CDV
INTERNATIONAL ELECTROTECHNICAL COMMISSION
–––––––––
BASIC ENVIRONMENTAL TESTING PROCEDURES –
Part 2: Tests – Test Db and guidance:
Damp heat, cyclic (12 + 12-hour cycle)
FOREWORD
1) The formal decisions or agreements of the IEC on technical matters, prepared by technical committees on which
all the National Committees having a special interest therein are represented, express, as nearly as possible, an
international consensus of opinion on the subjects dealt with.
2) They have the form of recommendations for international use and they are accepted by the National Committees
in that sense.
3) In order to promote international unification, the IEC expresses the wish that all National Committees should
adopt the text of the IEC recommendation for their national rules in so far as national conditions will permit. Any
divergence between the IEC recommendation and the corresponding national rules should, as far as possible,
be clearly indicated in the latter.
PREFACE
This standard has been prepared by subcommittee WG 16: Climatic tests, of IEC technical committee
104: Environmental testing.
It forms the third edition of IEC 60068-2-30 and replaces the second edition issued in 1980. It includes
the revised text of the second edition, amendment 1 issued in 1985.
The text of this standard is based on the following documents:
Publications Six Months’ Rule Reports on voting Two Months’ Procedure Reports on voting
nd
60068-2-30 (2 104/235/CD 104/283/CC
edition)
Full information on the voting for the approval of this standard can be found in the reports on voting
indicated in the above table.
The following IEC publications are quoted in this standard:
Publications Nos.
60068-1: Basic environmental testing procedures – Part 1: General.
60068-2-28: Part 2: Tests – Guidance for damp heat tests.
60068-3-6: Environmental testing – Supporting documentation and guidance –
Confirmation of the performance of temperature/humidity chambers.
---------------------- Page: 3 ----------------------
60068-2-30 © IEC – 4 – 104/330/CDV
BASIC ENVIRONMENTAL TESTING PROCEDURES –
Part 2: Tests – Test Db and guidance:
Damp heat, cyclic (12 + 12-hour cycle)
INTRODUCTION
1 Scope
To determine the suitability of components, equipment or other articles for use, transportation
and storage under conditions of high humidity - combined with cyclic temperature changes and,
in general, producing condensation on the surface of the specimen. If the test is being used to
verify the performance of a specimen whilst it is being transported or stored in packaging then
the packaging shall normally be fitted when the test conditions are being applied.
2 General description
This test comprises one or more temperature cycles in which the relative humidity is
maintained at a high level.
Two variants of the cycle are given which are identical except for the temperature fall period;
during this part of the cycle, variant 2 allows wider tolerances of relative humidity and the rate
of temperature fall.
The upper temperature of the cycle and the number of cycles (see clause 4) determine the test
severity.
Test profiles illustrating the procedure are shown in Figures 1, 2a, 2b and 3.
3 Testing chamber
The chamber shall be so constructed that the conditions given hereafter may be obtained:
3.1 The temperature can be varied cyclically between 25 ± 3 °C and the appropriate upper
temperature specified with the tolerance and rate of change specified in 6.3 and Figures 2a or
2b, as applicable.
3.2 The relative humidity in the working space can be maintained within the limits given in 6.3
and in Figures 2a or 2b, as applicable.
3.3 Care shall be taken to ensure that the conditions prevailing at any point in the working
space are uniform and are as similar as possible to those prevailing in the immediate vicinity of
suitably located temperature and humidity sensing devices. The chamber shall meet the
performance criteria as detailed in IEC 60068-3-6.
3.4 The specimens under test shall not be subjected to radiant heat from the chamber
conditioning processes.
---------------------- Page: 4 ----------------------
60068-2-30 © IEC – 5 – 104/330/CDV
3.5 Water used for the maintenance of chamber humidity shall have a resistivity of not less
than 500 Ωm.
Condensed water shall be continuously drained from the chamber and not used again until it
has been re-purified.
Precautions shall be taken to ensure that no condensed water is allowed to fall on the
specimens.
3.6 The dimensions, properties and/or electrical loading of the specimens under test shall not
appreciably influence conditions within the chamber.
4 Severities
4.1 The combination of the upper temperature and the number of cycles define the severity of
the test.
4.2 The severity shall be chosen from the fol
...
Questions, Comments and Discussion