SIST EN 14211:2025/oprA1:2026
(Amendment)Ambient air - Standard method for the measurement of the concentration of nitrogen dioxide and nitrogen monoxide by chemiluminescence
- Abstract
This document specifies a continuous measurement method for the determination of the concentrations of nitrogen dioxide and nitrogen monoxide present in ambient air based on the chemiluminescence measuring principle. This document describes the performance characteristics and sets the relevant minimum criteria required to select an appropriate chemiluminescence analyser by means of type testing. It also includes the evaluation of the suitability of an analyser for use in a specific fixed site so as to meet the data quality requirements as specified in Annex I of Directive 2008/50/EC [1] and requirements during sampling, calibration and quality assurance for use.
The method is applicable to the determination of the concentration of nitrogen dioxide present in ambient air up to 500 µg/m3. This concentration range represents the certification range for nitrogen dioxide for type testing.
The method is applicable to the determination of the concentration of nitrogen monoxide present in ambient air up to 1 200 µg/m3. This concentration range represents the certification range for nitrogen monoxide for the type testing.
NOTE 1 It is possible to use other ranges depending on the levels present in ambient air.
NOTE 2 When this document is used for purposes other than for measurements required by Directive2008/50/EC, the ranges and uncertainty requirements possibly do not apply.
The method covers the determination of ambient air concentrations of nitrogen dioxide and nitrogen monoxide in zones classified as rural areas, urban-background areas, traffic-orientated locations and locations influenced by industrial sources.
The results are expressed in µg/m3 (at 20 °C and 101,3 kPa).
NOTE 3 500 µg/m3 of nitrogen dioxide corresponds to 261 nmol/mol of nitrogen dioxide at 20 °C and 101,3 kPa. 1 200 µg/m3 of nitrogen monoxide corresponds to 962 nmol/mol of nitrogen monoxide at 20 °C and 101,3 kPa.
This document contains information for different groups of users.
Clause 5 to Clause 7 and Annex B and Annex C contain general information about the principles of NOx measurement by chemiluminescence analyser and sampling equipment.
Clause 8 and Annex E are specifically directed towards test houses and laboratories that perform type testing of NOx analysers. These sections contain information about:
— type testing conditions, test procedures and test requirements;
— analyser performance requirements;
— evaluation of the type testing results;
— evaluation of the uncertainty of the measurement results of the NOx analyser based on the type testing results.
Clause 9 to Clause 11 and Annex F and Annex G are directed towards monitoring networks performing the practical measurements of NOx in ambient air. These sections contain information about:
— initial installation of the analyser in the monitoring network and acceptance testing;
— ongoing quality assurance/quality control;
— calculation and reporting of measurement results;
— evaluation of the uncertainty of measurement results under practical monitoring conditions.
This document represents an evolution of earlier editions (EN 14211:2005 and EN 14211:2012). It is advisable that when equipment is procured it complies fully with this document.
NOTE 4 Type testing performed prior to the publication of this document for the purpose of demonstrating equivalence are still valid.
NOTE 5 Analysers type tested prior to the publication of this document remain valid for use for regulated monitoring purposes.
- Status
- Not Published
- Public Enquiry End Date
- 02-Jan-2027
- Technical Committee
- KAZ - Air quality
- Current Stage
- 4020 - Public enquire (PE) (Adopted Project)
- Start Date
- 05-Nov-2026
- Due Date
- 25-Mar-2027
SIST EN 14211:2025/oprA1:2026 is a draft amendment from CEN for the ambient-air chemiluminescence method used to measure nitrogen dioxide and nitrogen monoxide. It updates the requirements for type testing, fixed-site use, sampling, calibration, quality assurance and uncertainty evaluation, so laboratories, test houses and monitoring networks can apply the method consistently.
What does SIST EN 14211:2025/oprA1:2026 specify?
SIST EN 14211:2025/oprA1:2026 specifies changes to the European standard for continuous measurement of nitrogen dioxide and nitrogen monoxide in ambient air by chemiluminescence. The method is intended for ambient-air locations such as rural areas, urban-background areas, traffic-orientated locations and places influenced by industrial sources.
The document keeps the focus on two uses:
- selecting and type testing a suitable chemiluminescence analyser
- evaluating whether an analyser is fit for a specific fixed site and for routine monitoring work
The amendment is organised as a short change document with a foreword and 17 modification items. Those items touch the scope, terms and definitions, sampling system, performance criteria, linearity, long-term drift, maintenance intervals, calibration wording and uncertainty calculations.
| Annex | What it covers |
|---|---|
| Annex B | General information on NOx measurement by chemiluminescence analyser |
| Annex C | General information on sampling equipment |
| Annex E | Type testing for NOx analysers |
| Annex F | Practical monitoring use and uncertainty evaluation |
| Annex G | Practical monitoring use and uncertainty evaluation |
What are the key requirements of SIST EN 14211:2025/oprA1:2026?
SIST EN 14211:2025/oprA1:2026 mainly tightens and clarifies the technical checks that support ambient-air NO2 and NO measurement. In practice, it changes how users verify analyser performance, interpret drift and maintain the sampling system.
Key points that matter in use
Ambient air definition - Clause 3 now states more clearly that ambient air excludes workplaces as defined by Directive 89/654/EEC. This matters when deciding whether a site falls within the intended regulatory use of the method.
Sampling pump to manifold - Clause 6.5 requires the influence of pressure drop from the manifold sampling pump to stay below the stated limit. This matters because the sampling train itself must not bias the reported concentration.
Performance criteria - Clause 8.2 updates the criteria for repeatability, residual at zero, interferents such as water vapour, carbon dioxide and ammonia, and long-term drift. The practical effect is that an analyser must show stable zero and concentration behaviour and controlled cross-sensitivity before it is accepted for use.
Linearity testing - Clause 8.4.6 changes the calibration-function test to use a defined sequence of concentrations across the certification range and requires a stable reading after each step. This matters for laboratories because the analyser must settle before each measurement is taken.
Long-term drift - Clause 8.5.4 corrects the drift calculation wording and the reference point used in the calculation. This matters for data quality because drift values must be computed from the right baseline.
Calibration, checks and maintenance - Clause 9.4.2 and Clause 9.5 update the routine checks for the sampling manifold, particle filters, sampling lines and analyser calibration. Monitoring networks need to follow the revised maintenance logic, not just run the analyser continuously.
Uncertainty evaluation - Annex E, Annex F and Annex G update the uncertainty treatment for electrical voltage, other interferents and calibration gas, and they revise the combined standard uncertainty wording. This matters when reporting whether field measurements meet the required uncertainty budget.
What terms does SIST EN 14211:2025/oprA1:2026 define?
SIST EN 14211:2025/oprA1:2026 uses a small set of terms that are central to applying the method correctly.
- Ambient air - Outdoor air in the troposphere, excluding workplaces, where the public does not have regular access.
- Chemiluminescence - The light-producing measuring principle used by the analyser to determine NO2 and NO.
- Nitrogen dioxide (NO2) - One of the two gases measured by the method, reported as a concentration in ambient air.
- Nitrogen monoxide (NO) - The second target gas measured by the method.
- Type testing - Laboratory evaluation used to show that an analyser meets the required performance criteria.
- Monitoring network - A fixed-site air-quality system that installs the analyser, performs routine checks and reports results.
- Availability - A measure used in type testing to show whether the analyser is usable over the relevant period.
- Combined standard uncertainty - The combined uncertainty value used in the annexes to judge measurement quality.
Who uses SIST EN 14211:2025/oprA1:2026?
SIST EN 14211:2025/oprA1:2026 is used by test houses, laboratories, air-quality monitoring networks and organisations that buy or specify NOx analysers. Test houses and laboratories use it for type testing and performance evaluation. Monitoring networks use it for installation, acceptance testing, routine quality assurance and quality control, result calculation and uncertainty evaluation. Procurement teams and quality managers use it to specify analyser performance and to check that equipment and procedures match the intended regulatory monitoring use.
What changed in SIST EN 14211:2025/oprA1:2026 from the previous edition?
SIST EN 14211:2025/oprA1:2026 is a draft amendment to EN 14211:2024, and it corrects or clarifies specific technical points rather than rewriting the whole method. The amendment updates the scope note, the definition of ambient air, the sampling-pump clause, the performance criteria table, the linearity procedure, the long-term drift wording, the maintenance table, the calibration wording and the uncertainty calculations in Annex E, Annex F and Annex G.
The underlying standard is described as an evolution of EN 14211:2005 and EN 14211:2012.
Which standards are used with SIST EN 14211:2025/oprA1:2026?
The main external reference named in SIST EN 14211:2025/oprA1:2026 is Council Directive 2008/50/EC, which is used for the ambient-air definition, the data-quality context and the certification ranges. The amended definition of ambient air also refers to Directive 89/654/EEC for the workplace exclusion.
Within the document, Annex B and Annex C provide the background material on the measurement principle and sampling equipment, while Annex E, Annex F and Annex G support type testing and practical monitoring work.
What does the SIST EN 14211:2025/oprA1:2026 document contain?
SIST EN 14211:2025/oprA1:2026 contains a foreword and 17 modification items that revise selected clauses and annexes of EN 14211:2024. The changes cover the scope, terms, sampling system, performance criteria, calibration, maintenance and uncertainty treatment.
The document also points to tables and formulas that support the method: performance criteria, required maintenance frequency, type-testing requirements and combined standard uncertainty calculations. In practice, those parts are used for method selection, laboratory testing, installation checks, routine monitoring and quality assurance documentation.
Relations
- Effective Date
- 01-Dec-2026
Get Certified
Connect with accredited certification bodies for this standard
CIS Institut d.o.o.
Personal Protective Equipment (PPE) certification body. Notified Body NB-2890 for EU Regulation 2016/425 PPE.

Kiwa BDA Testing
Building and construction product certification.
Kmetijski inštitut Slovenije
Agricultural Institute of Slovenia. Soil testing, plant health, agricultural product analysis.
Sponsored listings
Frequently Asked Questions
SIST EN 14211:2025/oprA1:2026 is a draft published by the Slovenian Institute for Standardization (SIST). Its full title is "Ambient air - Standard method for the measurement of the concentration of nitrogen dioxide and nitrogen monoxide by chemiluminescence". This standard covers: This document specifies a continuous measurement method for the determination of the concentrations of nitrogen dioxide and nitrogen monoxide present in ambient air based on the chemiluminescence measuring principle. This document describes the performance characteristics and sets the relevant minimum criteria required to select an appropriate chemiluminescence analyser by means of type testing. It also includes the evaluation of the suitability of an analyser for use in a specific fixed site so as to meet the data quality requirements as specified in Annex I of Directive 2008/50/EC [1] and requirements during sampling, calibration and quality assurance for use. The method is applicable to the determination of the concentration of nitrogen dioxide present in ambient air up to 500 µg/m3. This concentration range represents the certification range for nitrogen dioxide for type testing. The method is applicable to the determination of the concentration of nitrogen monoxide present in ambient air up to 1 200 µg/m3. This concentration range represents the certification range for nitrogen monoxide for the type testing. NOTE 1 It is possible to use other ranges depending on the levels present in ambient air. NOTE 2 When this document is used for purposes other than for measurements required by Directive2008/50/EC, the ranges and uncertainty requirements possibly do not apply. The method covers the determination of ambient air concentrations of nitrogen dioxide and nitrogen monoxide in zones classified as rural areas, urban-background areas, traffic-orientated locations and locations influenced by industrial sources. The results are expressed in µg/m3 (at 20 °C and 101,3 kPa). NOTE 3 500 µg/m3 of nitrogen dioxide corresponds to 261 nmol/mol of nitrogen dioxide at 20 °C and 101,3 kPa. 1 200 µg/m3 of nitrogen monoxide corresponds to 962 nmol/mol of nitrogen monoxide at 20 °C and 101,3 kPa. This document contains information for different groups of users. Clause 5 to Clause 7 and Annex B and Annex C contain general information about the principles of NOx measurement by chemiluminescence analyser and sampling equipment. Clause 8 and Annex E are specifically directed towards test houses and laboratories that perform type testing of NOx analysers. These sections contain information about: — type testing conditions, test procedures and test requirements; — analyser performance requirements; — evaluation of the type testing results; — evaluation of the uncertainty of the measurement results of the NOx analyser based on the type testing results. Clause 9 to Clause 11 and Annex F and Annex G are directed towards monitoring networks performing the practical measurements of NOx in ambient air. These sections contain information about: — initial installation of the analyser in the monitoring network and acceptance testing; — ongoing quality assurance/quality control; — calculation and reporting of measurement results; — evaluation of the uncertainty of measurement results under practical monitoring conditions. This document represents an evolution of earlier editions (EN 14211:2005 and EN 14211:2012). It is advisable that when equipment is procured it complies fully with this document. NOTE 4 Type testing performed prior to the publication of this document for the purpose of demonstrating equivalence are still valid. NOTE 5 Analysers type tested prior to the publication of this document remain valid for use for regulated monitoring purposes.
This document specifies a continuous measurement method for the determination of the concentrations of nitrogen dioxide and nitrogen monoxide present in ambient air based on the chemiluminescence measuring principle. This document describes the performance characteristics and sets the relevant minimum criteria required to select an appropriate chemiluminescence analyser by means of type testing. It also includes the evaluation of the suitability of an analyser for use in a specific fixed site so as to meet the data quality requirements as specified in Annex I of Directive 2008/50/EC [1] and requirements during sampling, calibration and quality assurance for use. The method is applicable to the determination of the concentration of nitrogen dioxide present in ambient air up to 500 µg/m3. This concentration range represents the certification range for nitrogen dioxide for type testing. The method is applicable to the determination of the concentration of nitrogen monoxide present in ambient air up to 1 200 µg/m3. This concentration range represents the certification range for nitrogen monoxide for the type testing. NOTE 1 It is possible to use other ranges depending on the levels present in ambient air. NOTE 2 When this document is used for purposes other than for measurements required by Directive2008/50/EC, the ranges and uncertainty requirements possibly do not apply. The method covers the determination of ambient air concentrations of nitrogen dioxide and nitrogen monoxide in zones classified as rural areas, urban-background areas, traffic-orientated locations and locations influenced by industrial sources. The results are expressed in µg/m3 (at 20 °C and 101,3 kPa). NOTE 3 500 µg/m3 of nitrogen dioxide corresponds to 261 nmol/mol of nitrogen dioxide at 20 °C and 101,3 kPa. 1 200 µg/m3 of nitrogen monoxide corresponds to 962 nmol/mol of nitrogen monoxide at 20 °C and 101,3 kPa. This document contains information for different groups of users. Clause 5 to Clause 7 and Annex B and Annex C contain general information about the principles of NOx measurement by chemiluminescence analyser and sampling equipment. Clause 8 and Annex E are specifically directed towards test houses and laboratories that perform type testing of NOx analysers. These sections contain information about: — type testing conditions, test procedures and test requirements; — analyser performance requirements; — evaluation of the type testing results; — evaluation of the uncertainty of the measurement results of the NOx analyser based on the type testing results. Clause 9 to Clause 11 and Annex F and Annex G are directed towards monitoring networks performing the practical measurements of NOx in ambient air. These sections contain information about: — initial installation of the analyser in the monitoring network and acceptance testing; — ongoing quality assurance/quality control; — calculation and reporting of measurement results; — evaluation of the uncertainty of measurement results under practical monitoring conditions. This document represents an evolution of earlier editions (EN 14211:2005 and EN 14211:2012). It is advisable that when equipment is procured it complies fully with this document. NOTE 4 Type testing performed prior to the publication of this document for the purpose of demonstrating equivalence are still valid. NOTE 5 Analysers type tested prior to the publication of this document remain valid for use for regulated monitoring purposes.
SIST EN 14211:2025/oprA1:2026 is classified under the following ICS (International Classification for Standards) categories: 13.040.20 - Ambient atmospheres. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 14211:2025/oprA1:2026 has the following relationships with other standards: It is inter standard links to SIST EN 14211:2025. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
SIST EN 14211:2025/oprA1:2026 is associated with the following European legislation: EU Directives/Regulations: 2008/50/EC. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
SIST EN 14211:2025/oprA1:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-december-2026
Zunanji zrak - Standardna metoda za določanje koncentracije dušikovega dioksida
in dušikovega monoksida s kemiluminiscenco - Dopolnilo A1
Ambient air - Standard method for the measurement of the concentration of nitrogen
dioxide and nitrogen monoxide by chemiluminescence
Außenluft - Messverfahren zur Bestimmung der Konzentration von Stickstoffdioxid und
Stickstoffmonoxid mit Chemilumineszenz
Air ambiant - Méthode normalisée pour le mesurage de la concentration en dioxyde
d'azote et monoxyde d'azote par chimiluminescence
Ta slovenski standard je istoveten z: EN 14211:2024/prA1
ICS:
13.040.20 Kakovost okoljskega zraka Ambient atmospheres
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
DRAFT
EUROPEAN STANDARD
EN 14211:2024
NORME EUROPÉENNE
EUROPÄISCHE NORM
prA1
October 2026
ICS
English Version
Ambient air - Standard method for the measurement of the
concentration of nitrogen dioxide and nitrogen monoxide
by chemiluminescence
Air ambiant - Méthode normalisée pour le mesurage de Außenluft - Messverfahren zur Bestimmung der
la concentration en dioxyde d'azote et monoxyde Konzentration von Stickstoffdioxid und
d'azote par chimiluminescence Stickstoffmonoxid mit Chemilumineszenz
This draft amendment is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee CEN/TC 264.
This draft amendment A1, if approved, will modify the European Standard EN 14211:2024. If this draft becomes an amendment,
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for inclusion of
this amendment into the relevant national standard without any alteration.
This draft amendment was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and
United Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.
Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without
notice and shall not be referred to as a European Standard.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2026 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 14211:2024/prA1:2026 E
worldwide for CEN national Members.
Contents Page
European foreword . 3
1 Modification to Clause 1 ”Scope” . 4
2 Modification to Clause 3 "Terms and definitions" . 4
3 Modifications to 6.5 “Sampling pump to manifold” . 4
4 Modifications to 8.2, "Relevant performance characteristics and criteria", . 4
5 Modifications to 8.2, "Relevant performance characteristics and criteria" . 5
6 Modification to 8.4.6, "Lack of fit of linearity of the calibration function” . 5
7 Modifications to 8.5.4, "Long-term drift" . 6
8 Modifications to 9.4.2 Table 9 ‘Required frequency of calibration, checks and
maintenance‘ . 6
9 Modification to 9.5, "Calibration of the analyser" . 7
10 Modification to E.3.2.5.5, "Electric voltage", . 7
11 Modification to E.3.2.5.7, "Other interferents" . 7
12 Modification to E.3.2.5.9, "Calibration gas" . 8
13 Modifications to E.4, “Type testing Requirement d)” . 8
14 Modification to E.5.2, "Combined standard uncertainty" . 8
15 Modification to F.2 “Combined standard uncertainty” . 8
16 Modification to G.2 “Combined standard uncertainty” . 9
17 Modification to G.3.5.5, "Electrical voltage" . 9
European foreword
This document (EN 14211:2024/prA1:2026) has been prepared by Technical Committee CEN/TC 264
“Air quality”, the secretariat of which is held by DIN.
This document is currently submitted to the CEN Enquiry.
This amendment addresses only the critical errors identified in the EN 14211:2024. Errors considered as
minor by CEN/TC 264/WG 12 will be addressed in the subsequent revision of EN 14211.
This document has been prepared under a Standardization Request given to CEN by the European
Commission and the European Free Trade Association, and supports essential requirements of
EU Directive(s) / Regulation(s).
EN 14211/prA1:2026 (E)
1 Modification to Clause 1 ”Scope”
Remove the following sentence from Note 4:
“As newer versions of analysers tested under this document become available, discontinue the use of
older reference analysers.”.
2 Modification to Clause 3 "Terms and definitions"
Replace definition 3.2 ambient air:
“3.2
ambient air
outdoor air in the troposphere where provisions concerning health and safety at work apply and to which
members of the public do not have regular access
[SOURCE: Council Directive 2008/50/EC [1]]”
with the following:
“3.2
ambient air
outdoor air in the troposphere, excluding workplaces as defined by Directive 89/654/EEC, where
provisions concerning health and safety at work apply, and to which members of the public do not have
regular access.
[SOURCE: Council Directive 2008/50/EC [1]]”.
3 Modifications to 6.5 “Sampling pump to manifold”
Replace “(see 9.5.4.3)” with “(see 9.6.4)”.
In the last sentence, replace
“≤ 1,0 %.”
With
“< 1,0 %.”
to read
“The influence of the pressure drop induced by the manifold sampling pump on the measured
concentration shall be < 1,0 %.”
4 Modifications
...