F14.35 - Architectural Metal Fence Systems
Architectural Metal Fence Systems
General Information
ABSTRACT
This specification establishes the minimum requirements for coated tubular picket ornamental fence systems fabricated from galvanized steel components. Steel material for tubular picket ornamental fence system structural components shall be galvanized by the hot-dip process, either after forming, or prior to forming. Powder coatings applied to the exterior surface of fence components shall be polymer material: polyester or epoxy and polyester combinations. Wet coating applied to the exterior surface of fence components shall be a two-coat paint application system (one coat of epoxy, polyester or polyurethane primer; one coat of polyester, polyurethane, or acrylic liquid). Fittings, fasteners, and decorative accessories for ornamental steel fence systems shall be manufactured with a material and finish coating that meets the same protective coating performance requirements as required for panels and posts. Four structural test methods shall be conducted: Method A which is application of horizontal concentrated load, Method B which is application of vertical concentrated load, Method C which is application of horizontal thrust load to infill areas, and Method D which is application of horizontal cone penetration load. Different tests shall also be performed in order to determine the following properties of the fence system coatings: adhesion, corrosion resistance, impact resistance, and weathering resistance.
SCOPE
1.1 This specification establishes the minimum requirements for coated tubular picket ornamental fence systems fabricated from galvanized steel components.
1.2 The requirements of this specification do not apply to vertical bar fence systems utilizing solid bar or wrought iron materials.
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Technical specification7 pagesEnglish language
SCOPE
1.1 This specification establishes the minimum requirements for coated tubular picket ornamental fence systems fabricated from black (that is, not galvanized) steel components.
1.2 The requirements of this specification do not apply to vertical bar fence systems utilizing solid bar or wrought iron materials.
1.3 The values stated with inch-pound units are to be regarded as standard. The SI values in parentheses are provided for information.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Technical specification7 pagesEnglish language
ABSTRACT
This specification covers the selection and installation of expanded metal fence systems for applications on new or retrofit fences capable of denying or delaying unwanted access into or out of a commercial, industrial, governmental, or institutional facility as applicable to homeland security, or where the possibility of malevolent incursion is significant. The metal fences can be expanded (Type 1), or expanded and flattened (Type 2); and uncoated (Class 1), hot-dip zinc coated or galvanized (Class 2), or corrosion-resisting steel (Class 3). Fencings shall conform to specified standard sizes and dimensions.
SCOPE
1.1 This specification covers selection and installation of expanded metal fence systems for applications on new or retrofit fences for commercial, industrial, governmental, or institutional facilities as applicable to homeland security, or where the possibility of malevolent incursion is significant. See Fig. 1 for typical examples of expanded metal fence applications. This type of fence system is not recommended for residential or public recreational facilities such as pools, schools, and kindergartens.
FIG. 1 Expanded Metal Fencing Applications
1.2 This specification is intended to guide those responsible for or concerned with the design and installation of an expanded metal fence system capable of denying or delaying unwanted access into or out of an area.
1.3 No recommendation is made or implied here as to the merits of the product from any particular manufacturer. Choice of component selection for the expanded metal system should be made by the writer of the project specification based on their own perception of the product’s merit and the consequence of a malevolent incursion.
1.4 Units—The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.5 This specification does not purport to address all of the safety and security concerns, if any, associated with homeland security. It is the responsibility of the user of this standard to establish the required and appropriate level of security.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Technical specification5 pagesEnglish language
- Technical specification5 pagesEnglish language
ABSTRACT
This specification establishes the minimum requirements for architecturally coated, tubular picket, ornamental aluminum fence systems, namely, aluminum wrought iron fence, architectural metal fence, ornamental aluminum fence, ornamental fence, ornamental metal fence, picket fence, tubular picket fence, and vertical tube fence. The standard covers materials and their manufacture, structural testing, physical dimensions of the fence systems, workmanship, testing of surface finish, and certification.
SCOPE
1.1 This specification establishes the minimum requirements for architecturally coated, tubular picket, ornamental aluminum fence systems.
1.2 The values stated in inch-pound units are to be regarded as standard. No other units of measurement are included in this standard.
1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Technical specification4 pagesEnglish language
ABSTRACT
This specification covers welded wire mesh fence fabric produced from steel wire or metallic-coated steel wire. The metallic-coated fabric may be polymer coated after fabrication. Welded wire mesh fence fabric is classified in accordance with coating as follows: Type 1; Type 2; Type 3; and Type 4. Tests shall be performed to determine the properties of the material in accordance with the following test methods: metallic coating weight; polymer coating thickness; polymer adhesion test; and weld shear strength of fabric.
SCOPE
1.1 This specification covers welded wire mesh fence fabric produced from steel wire or metallic-coated steel wire. The metallic-coated fabric may be polymer coated after fabrication.
1.2 Welded wire mesh fence fabric is produced in four types, based on the kind of coating, as described in Section 4.
1.3 This specification is applicable to orders in either inch-pound units or SI units. Values stated in either inch-pound or SI units are to be regarded separately as the standard. Within the text, the SI units are shown in brackets. The values in the two systems are not exact equivalents; therefore, each system shall be used independent of the other, without combining values in any way.
1.4 This specification references notes and footnotes, which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of this specification.
1.5 The following safety hazards caveat pertains only to the test methods portion, Section 13, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations proper to use.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Technical specification6 pagesEnglish language
ABSTRACT
This specification covers welded wire mesh fence fabric produced from steel wire or metallic-coated steel wire. The metallic-coated fabric may be polymer coated after fabrication. This specification identifies the three major classifications of welded wire mesh fence fabric - Panel Sizes Model A, B, and C - and the test methods conducted on the welded wire fabric. It also indicates the physical properties, dimension, tolerance, and workmanship of the welded wire mesh fence fabric.
SCOPE
1.1 This specification covers welded wire mesh fence fabric produced from steel wire or metallic-coated steel wire. The metallic-coated fabric may be polymer coated after fabrication.
1.2 Welded wire mesh fence fabric is produced in four types, based on the kind of coating, as described in Section 4.
1.3 This specification is applicable to orders in either inch-pound units or SI units. Values stated in either inch-pound or SI units are to be regarded separately as the standard. Within the text, the SI units are shown in brackets. The values in the two systems are not exact equivalents; therefore, each system shall be used independent of the other, without combining values in any way.
1.4 This specification references notes and footnotes, which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of this specification.
1.5 The following safety hazards caveat pertains only to the test methods portion, 13.4, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Technical specification7 pagesEnglish language
ABSTRACT
This specification covers the selection and installation of expanded metal fence systems for applications on new or retrofit fences capable of denying or delaying unwanted access into or out of a commercial, industrial, governmental, or institutional facility as applicable to homeland security, or where the possibility of malevolent incursion is significant. The metal fences can be expanded (Type 1), or expanded and flattened (Type 2); and uncoated (Class 1), hot-dip zinc coated or galvanized (Class 2), or corrosion-resisting steel (Class 3). Fencings shall conform to specified standard sizes and dimensions.
SCOPE
1.1 This specification covers selection and installation of expanded metal fence systems for applications on new or retrofit fences for commercial, industrial, governmental or institutional facilities as applicable to homeland security, or where the possibility of malevolent incursion is significant. See Fig. 1 for typical examples of expanded metal fence applications. This type of fence system is not recommended for residential or public recreational facilities such as pools, schools, and kindergartens.
FIG. 1 Expanded Metal Fencing Applications
1.2 This specification is intended to guide those responsible for or concerned with the design and installation of an expanded metal fence system capable of denying or delaying unwanted access into or out of an area.
1.3 No recommendation is made or implied here as to the merits of the product from any particular manufacturer. Choice of component selection for the expanded metal system should be made by the writer of the project specification based on their own perception of the product’s merit and the consequence of a malevolent incursion.
1.4 The values stated in inch-pound units are to be regarded as standard. Any values given in parentheses are for information only.
1.5 This specification does not purport to address all of the safety and security concerns, if any, associated with homeland security. It is the responsibility of the user of this standard to establish the required and appropriate level of security.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Technical specification5 pagesEnglish language
- Technical specification5 pagesEnglish language
SCOPE
1.1 This specification establishes the minimum requirements for coated tubular picket ornamental fence systems fabricated from black (that is, not galvanized) steel components.
1.2 The requirements of this specification do not apply to vertical bar fence systems utilizing solid bar or wrought iron materials.
1.3 The values stated with inch-pound units are to be regarded as standard. The SI values in parentheses are provided for information.
- Technical specification7 pagesEnglish language
- Technical specification7 pagesEnglish language
ABSTRACT
This specification establishes the minimum requirements for coated tubular picket ornamental fence systems fabricated from galvanized steel components. Steel material for tubular picket ornamental fence system structural components shall be galvanized by the hot-dip process, either after forming, or prior to forming. Powder coatings applied to the exterior surface of fence components shall be polymer material: polyester or epoxy and polyester combinations. Wet coating applied to the exterior surface of fence components shall be a two-coat paint application system (one coat of epoxy, polyester or polyurethane primer; one coat of polyester, polyurethane, or acrylic liquid). Fittings, fasteners, and decorative accessories for ornamental steel fence systems shall be manufactured with a material and finish coating that meets the same protective coating performance requirements as required for panels and posts. Four structural test methods shall be conducted: Method A which is application of horizontal concentrated load, Method B which is application of vertical concentrated load, Method C which is application of horizontal thrust load to infill areas, and Method D which is application of horizontal cone penetration load. Different tests shall also be performed in order to determine the following properties of the fence system coatings: adhesion, corrosion resistance, impact resistance, and weathering resistance.
SCOPE
1.1 This specification establishes the minimum requirements for coated tubular picket ornamental fence systems fabricated from galvanized steel components.
1.2 The requirements of this specification do not apply to vertical bar fence systems utilizing solid bar or wrought iron materials.
1.3 The values stated with in-pound units are to be regarded as standard. The SI values in parentheses are provided for information.
- Technical specification7 pagesEnglish language
- Technical specification7 pagesEnglish language
ABSTRACT
This specification covers welded wire mesh fence fabric produced from steel wire or metallic-coated steel wire. The metallic-coated fabric may be polymer coated after fabrication. Welded wire mesh fence fabric is classified in accordance with coating as follows: Type 1; Type 2; Type 3; and Type 4. Tests shall be performed to determine the properties of the material in accordance with the following test methods: metallic coating weight; polymer coating thickness; polymer adhesion test; and weld shear strength of fabric.
SCOPE
1.1 This specification covers welded wire mesh fence fabric produced from steel wire or metallic-coated steel wire. The metallic-coated fabric may be polymer coated after fabrication.
1.2 Welded wire mesh fence fabric is produced in four types, based on the kind of coating, as described in Section 4.
1.3 This specification is applicable to orders in either inch-pound units or SI units. Values stated in either inch-pound or SI units are to be regarded separately as the standard. Within the text, the SI units are shown in brackets. The values in the two systems are not exact equivalents; therefore, each system shall be used independent of the other, without combining values in any way.
1.4 This specification references notes and footnotes, which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of this specification.
1.5 The following safety hazards caveat pertains only to the test methods portion, Section 13, of this specification: This standard does not purport to address all of the safety concerns, if any associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations proper to use.
- Technical specification6 pagesEnglish language
- Technical specification6 pagesEnglish language
ABSTRACT
This specification establishes the minimum requirements for architecturally coated, tubular picket, ornamental aluminum fence systems, namely, aluminum wrought iron fence, architectural metal fence, ornamental aluminum fence, ornamental fence, ornamental metal fence, picket fence, tubular picket fence, and vertical tube fence. The standard covers materials and their manufacture, structural testing, physical dimensions of the fence systems, workmanship, testing of surface finish, and certification.
SCOPE
1.1 This specification establishes the minimum requirements for architecturally coated, tubular picket, ornamental aluminum fence systems.
- Technical specification4 pagesEnglish language
ABSTRACT
This specification covers the selection and installation of expanded metal fence systems for applications on new or retrofit fences capable of denying or delaying unwanted access into or out of a commercial, industrial, governmental, or institutional facility as applicable to homeland security, or where the possibility of malevolent incursion is significant. The metal fences can be expanded (Type 1), or expanded and flattened (Type 2); and uncoated (Class 1), hot-dip zinc coated or galvanized (Class 2), or corrosion-resisting steel (Class 3). Fencings shall conform to specified standard sizes and dimensions.
SCOPE
1.1 This specification covers selection and installation of expanded metal fence systems for applications on new or retrofit fences for commercial, industrial, governmental or institutional facilities as applicable to homeland security, or where the possibility of malevolent incursion is significant. See Fig. 1 for typical examples of expanded metal fence applications. This type of fence system is not recommended for residential or public recreational facilities such as pools, schools, and kindergartens.
FIG. 1 Expanded Metal Fencing Applications
1.2 This specification is intended to guide those responsible for or concerned with the design and installation of an expanded metal fence system capable of denying or delaying unwanted access into or out of an area.
1.3 No recommendation is made or implied here as to the merits of the product from any particular manufacturer. Choice of component selection for the expanded metal system should be made by the writer of the project specification based on their own perception of the product’s merit and the consequence of a malevolent incursion.
1.4 The values stated in inch-pound units are to be regarded as standard. Any values given in parentheses are for information only.
1.5 This specification does not purport to address all of the safety and security concerns, if any, associated with homeland security. It is the responsibility of the user of this standard to establish the required and appropriate level of security.
- Technical specification5 pagesEnglish language
- Technical specification5 pagesEnglish language
ABSTRACT
This specification covers welded wire mesh fence fabric produced from steel wire or metallic-coated steel wire. The metallic-coated fabric may be polymer coated after fabrication. This specification identifies the three major classifications of welded wire mesh fence fabric - Panel Sizes Model A, B, and C - and the test methods conducted on the welded wire fabric. It also indicates the physical properties, dimension, tolerance, and workmanship of the welded wire mesh fence fabric.
SCOPE
1.1 This specification covers welded wire mesh fence fabric produced from steel wire or metallic-coated steel wire. The metallic-coated fabric may be polymer coated after fabrication.
1.2 Welded wire mesh fence fabric is produced in four types, based on the kind of coating, as described in Section 4.
1.3 This specification is applicable to orders in either inch-pound units or SI units. Values stated in either inch-pound or SI units are to be regarded separately as the standard. Within the text, the SI units are shown in brackets. The values in the two systems are not exact equivalents; therefore, each system shall be used independent of the other, without combining values in any way.
1.4 This specification references notes and footnotes, which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of this specification.
1.5 The following safety hazards caveat pertains only to the test methods portion, 13.4, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Technical specification7 pagesEnglish language
ABSTRACT
This specification establishes the minimum requirements for coated tubular picket ornamental fence systems fabricated from galvanized steel components. Steel material for tubular picket ornamental fence system structural components shall be galvanized by the hot-dip process, either after forming, or prior to forming. Powder coatings applied to the exterior surface of fence components shall be polymer material: polyester or epoxy and polyester combinations. Wet coating applied to the exterior surface of fence components shall be a two-coat paint application system (one coat of epoxy, polyester or polyurethane primer; one coat of polyester, polyurethane, or acrylic liquid). Fittings, fasteners, and decorative accessories for ornamental steel fence systems shall be manufactured with a material and finish coating that meets the same protective coating performance requirements as required for panels and posts. Four structural test methods shall be conducted: Method A which is application of horizontal concentrated load, Method B which is application of vertical concentrated load, Method C which is application of horizontal thrust load to infill areas, and Method D which is application of horizontal cone penetration load. Different tests shall also be performed in order to determine the following properties of the fence system coatings: adhesion, corrosion resistance, impact resistance, and weathering resistance.
SCOPE
1.1 This specification establishes the minimum requirements for coated tubular picket ornamental fence systems fabricated from galvanized steel components.
1.2 The requirements of this specification do not apply to vertical bar fence systems utilizing solid bar or wrought iron materials.
1.3 The values stated with in-pound units are to be regarded as standard. The SI values in parentheses are provided for information.
- Technical specification7 pagesEnglish language
- Technical specification7 pagesEnglish language
SCOPE
1.1 This specification establishes the minimum requirements for coated tubular picket ornamental fence systems fabricated from black (that is, not galvanized) steel components.
1.2 The requirements of this specification do not apply to vertical bar fence systems utilizing solid bar or wrought iron materials.
1.3 The values stated with inch-pound units are to be regarded as standard. The SI values in parentheses are provided for information.
- Technical specification7 pagesEnglish language
- Technical specification7 pagesEnglish language
ABSTRACT
This specification covers welded wire mesh fence fabric produced from steel wire or metallic-coated steel wire. The metallic-coated fabric may be polymer coated after fabrication. Welded wire mesh fence fabric is classified in accordance with coating as follows: Type 1; Type 2; Type 3; and Type 4. Tests shall be performed to determine the properties of the material in accordance with the following test methods: metallic coating weight; polymer coating thickness; polymer adhesion test; and weld shear strength of fabric.
SCOPE
1.1 This specification covers welded wire mesh fence fabric produced from steel wire or metallic-coated steel wire. The metallic-coated fabric may be polymer coated after fabrication.
1.2 Welded wire mesh fence fabric is produced in four types, based on the kind of coating, as described in Section 4.
1.3 This specification is applicable to orders in either inch-pound units or SI units. Values stated in either inch-pound or SI units are to be regarded separately as the standard. Within the text, the SI units are shown in brackets. The values in the two systems are not exact equivalents; therefore, each system shall be used independent of the other, without combining values in any way.
1.4 This specification references notes and footnotes, which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of this specification.
1.5 The following safety hazards caveat pertains only to the test methods portion, Section 13, of this specification: This standard does not purport to address all of the safety concerns, if any associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations proper to use.
- Technical specification6 pagesEnglish language
ABSTRACT
This specification establishes the minimum requirements for coated tubular picket ornamental fence systems fabricated from galvanized steel components. Steel material for tubular picket ornamental fence system structural components shall be galvanized by the hot-dip process, either after forming, or prior to forming. Powder coatings applied to the exterior surface of fence components shall be polymer material: polyester or epoxy and polyester combinations. Wet coating applied to the exterior surface of fence components shall be a two-coat paint application system (one coat of epoxy, polyester or polyurethane primer; one coat of polyester, polyurethane, or acrylic liquid). Fittings, fasteners, and decorative accessories for ornamental steel fence systems shall be manufactured with a material and finish coating that meets the same protective coating performance requirements as required for panels and posts. Four structural test methods shall be conducted: Method A which is application of horizontal concentrated load, Method B which is application of vertical concentrated load, Method C which is application of horizontal thrust load to infill areas, and Method D which is application of horizontal cone penetration load. Different tests shall also be performed in order to determine the following properties of the fence system coatings: adhesion, corrosion resistance, impact resistance, and weathering resistance.
SCOPE
1.1 This specification establishes the minimum requirements for coated tubular picket ornamental fence systems fabricated from galvanized steel components.
1.2 The requirements of this specification do not apply to vertical bar fence systems utilizing solid bar or wrought iron materials.
1.3 The values stated with in-pound units are to be regarded as standard. The SI values in parentheses are provided for information.
- Technical specification7 pagesEnglish language
- Technical specification7 pagesEnglish language
ABSTRACT
This specification establishes the minimum requirements for coated tubular picket ornamental fence systems fabricated from galvanized steel components. Steel material for tubular picket ornamental fence system structural components shall be galvanized by the hot-dip process, either after forming, or prior to forming. Powder coatings applied to the exterior surface of fence components shall be polymer material: polyester or epoxy and polyester combinations. Wet coating applied to the exterior surface of fence components shall be a two-coat paint application system (one coat of epoxy, polyester or polyurethane primer; one coat of polyester, polyurethane, or acrylic liquid). Fittings, fasteners, and decorative accessories for ornamental steel fence systems shall be manufactured with a material and finish coating that meets the same protective coating performance requirements as required for panels and posts. Four structural test methods shall be conducted: Method A which is application of horizontal concentrated load, Method B which is application of vertical concentrated load, Method C which is application of horizontal thrust load to infill areas, and Method D which is application of horizontal cone penetration load. Different tests shall also be performed in order to determine the following properties of the fence system coatings: adhesion, corrosion resistance, impact resistance, and weathering resistance.
SCOPE
1.1 This specification establishes the minimum requirements for coated tubular picket ornamental fence systems fabricated from galvanized steel components.
1.2 The requirements of this specification do not apply to vertical bar fence systems utilizing solid bar or wrought iron materials.
1.3 The values stated with in-pound units are to be regarded as standard. The SI values in brackets are provided for information.
- Technical specification7 pagesEnglish language
SCOPE
1.1 This specification establishes the minimum requirements for coated tubular picket ornamental fence systems fabricated from galvanized steel components.
1.2 The requirements of this specification do not apply to vertical bar fence systems utilizing solid bar or wrought iron materials.
1.3 The values stated with in-pound units are to be regarded as standard. The SI values in brackets are provided for information.
- Technical specification7 pagesEnglish language
SCOPE
1.1 This specification establishes the minimum requirements for coated tubular picket ornamental fence systems fabricated from black (that is, not galvanized) steel components.
1.2 The requirements of this specification do not apply to vertical bar fence systems utilizing solid bar or wrought iron materials.
1.3 The values stated with inch-pound units are to be regarded as standard. The SI values in brackets are provided for information.
- Technical specification7 pagesEnglish language
ABSTRACT
This specification covers welded wire mesh fence fabric produced from steel wire or metallic-coated steel wire. The metallic-coated fabric may be polymer coated after fabrication. Welded wire mesh fence fabric is classified in accordance with coating as follows: Type 1; Type 2; Type 3; and Type 4. Tests shall be performed to determine the properties of the material in accordance with the following test methods: metallic coating weight; polymer coating thickness; polymer adhesion test; and weld shear strength of fabric.
SCOPE
1.1 This specification covers welded wire mesh fence fabric produced from steel wire or metallic-coated steel wire. The metallic-coated fabric may be polymer coated after fabrication.
1.2 Welded wire mesh fence fabric is produced in four types, based on the kind of coating, as described in Section .
1.3 This specification is applicable to orders in either inch-pound units or SI units. Values stated in either inch-pound or SI units are to be regarded separately as the standard. Within the text, the SI units are shown in brackets. The values in the two systems are not exact equivalents; therefore, each system shall be used independent of the other, without combining values in any way.
1.4 This specification references notes and footnotes, which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of this specification.
1.5 The following safety hazards caveat pertains only to the test methods portion, Section 13, of this specification: This standard does not purport to address all of the safety concerns, if any associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations proper to use.
- Technical specification6 pagesEnglish language
SCOPE
1.1 This specification establishes the minimum requirements for coated tubular picket ornamental fence systems fabricated from galvanized steel components.
1.2 The requirements of this specification do not apply to vertical bar fence systems utilizing solid bar or wrought iron materials.
1.3 The values stated with in-pound units are to be regarded as the standard. The SI values in brackets are provided for information.
- Technical specification7 pagesEnglish language
Frequently Asked Questions
F14.35 is a Technical Committee within ASTM International. It is named "Architectural Metal Fence Systems". This committee has published 22 standards.
F14.35 develops ASTM standards in the area of Information technology. Currently, there are 22 published standards from this technical committee.
ASTM is a standardization organization that develops and publishes standards to support industry, commerce, and regulatory requirements.
A Technical Committee (TC) in ASTM is a group of experts responsible for developing international standards in a specific technical area. TCs are composed of national member body delegates and work through consensus to create standards that meet global industry needs. Each TC may have subcommittees (SCs) and working groups (WGs) for specialized topics.