D33.10 - Protective Coatings Maintenance Work for Power Generation Facilities
Protective Coatings Maintenance Work for Power Generation Facilities
General Information
SIGNIFICANCE AND USE
5.1 There are several methods for managing non-conforming coatings in an operating nuclear power plant. This guide outlines methods that have been determined to be acceptable to the nuclear industry.
5.2 Managing the amount of non-conforming coatings is key to ensuring the amount assumed, in the licensing bases is not exceeded.
5.3 EPRI Report 1019157 provides additional information on the selection, application, inspection and maintenance of nuclear plant safety-related protective coatings. This reference offers a detailed discussion of important considerations related to protective coatings and can be used to supplement this guide as deemed necessary.
SCOPE
1.1 This guide provides the user with guidance on developing a program for managing non-conforming coatings in Coating Service Level I areas of a nuclear power plant.
1.2 Non-conforming coatings include degraded qualified or acceptable coatings, unqualified coatings, unknown coatings, and unacceptable coatings.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
- Guide4 pagesEnglish language
- Guide4 pagesEnglish language
SIGNIFICANCE AND USE
5.1 There are several methods for managing non-conforming coatings in an operating nuclear power plant. This guide outlines methods that have been determined to be acceptable to the nuclear industry.
5.2 Managing the amount of non-conforming coatings is key to ensuring the amount assumed, in the licensing bases is not exceeded.
5.3 EPRI Report 1003102 Revision 1 (formerly TR-109937) provides additional information on the selection, application, inspection and maintenance of nuclear plant safety-related protective coatings. This reference offers a detailed discussion of important considerations related to protective coatings and can be used to supplement this guide as deemed necessary.
SCOPE
1.1 This guide provides the user with guidance on developing a program for managing non-conforming coatings in Coating Service Level I areas of a nuclear power plant.
1.2 Non-conforming coatings include degraded previously DBA-qualified or acceptable coatings, unqualified coatings, unknown coatings, and unacceptable coatings.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Guide5 pagesEnglish language
- Guide5 pagesEnglish language
SIGNIFICANCE AND USE
There are several methods for managing non-conforming coatings in an operating nuclear power plant. This guide outlines methods that have been determined to be acceptable to the nuclear industry.
Managing the amount of non-conforming coatings is key to ensuring the amount assumed, in the licensing bases is not exceeded.
EPRI Report 1003102 Revision 1 (formerly TR-109937) provides additional information on the selection, application, inspection and maintenance of nuclear plant safety-related protective coatings. This reference offers a detailed discrussion of inportant considerations related to protective coatings and can be used to supplement this guide as deemed necessary.
SCOPE
1.1 This guide provides the user with guidance on developing a program for managing non-conforming coatings in Coating Service Level I areas of a nuclear power plant.
1.2 Non-conforming coatings include degraded previously DBA-qualified or acceptable coatings, unqualified coatings, unknown coatings, and unacceptable coatings.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
- Guide4 pagesEnglish language
SCOPE
1.1 This guide is intended to assist the maintenance engineer in the preparation of a specification or work instruction for re-coating items that are presently coated with what is known within the nuclear power industry as an "unqualified coating."
WITHDRAWN RATIONALE
This guide is intended to assist the maintenance engineer in the preparation of a specification or work instruction for re-coating items that are presently coated with what is known within the nuclear power industry as an “unqualified coating.”
Formerly under the jurisdiction of Committee D33 on Protective Coating and Lining Work for Power Generation Facilities, this guide was withdrawn in September 2008 in accordance with section 10.5.3.1 of the Regulations Governing ASTM Technical Committees, which requires that standards shall be updated by the end of the eighth year since the last approval date.
- Guide2 pagesEnglish language
Frequently Asked Questions
D33.10 is a Technical Committee within ASTM International. It is named "Protective Coatings Maintenance Work for Power Generation Facilities". This committee has published 4 standards.
D33.10 develops ASTM standards in the area of Information technology. Currently, there are 4 published standards from this technical committee.
ASTM is a standardization organization that develops and publishes standards to support industry, commerce, and regulatory requirements.
A Technical Committee (TC) in ASTM is a group of experts responsible for developing international standards in a specific technical area. TCs are composed of national member body delegates and work through consensus to create standards that meet global industry needs. Each TC may have subcommittees (SCs) and working groups (WGs) for specialized topics.