CEN/TC 191/WG 9 - Hydrant and hose reel systems
The design and construction of fixed first aid firefighting hose systems for installation in buildings or other construction works, and mounted on walls or in cabinets and permanently connected to a water supply; and the components used for such systems.
Hydrant and hose reel systems
The design and construction of fixed first aid firefighting hose systems for installation in buildings or other construction works, and mounted on walls or in cabinets and permanently connected to a water supply; and the components used for such systems.
General Information
This European Standard specifies requirements and methods of test for the construction and performance of fire hose reel systems with lay-flat hose for installation in buildings, permanently connected to a water supply, for use by the occupants.
Furthermore, it provides also for requirements on evaluation of conformity and marking of these products.
Its requirements may apply in general for other applications, for example in marine applications or in aggressive environments, but additional requirements may be necessary in such cases.
- Standard36 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements and methods of test for the construction and performance of fire hose reel systems with semi-rigid hose for installation in buildings, permanently connected to a water supply, for use by the occupants.
It also provides requirements on evaluation of conformity and marking of these products.
Its requirements may apply in general for other applications, for example in marine applications or in aggressive environments, but additional requirements can be necessary in such cases.
This European Standard is applicable to both manual and automatic fire hose reels for installation with and without cabinets.
- Standard42 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements for inspection and maintenance of hose reels and hose systems such that they continue to provide the service for which they were manufactured, supplied or installed i.e. to ensure a first emergency intervention to fight a fire before more powerful means can be implemented.
This European Standard is applicable to hose reel and hose system installations in all types of buildings irrespective of the nature of use of the buildings.
- Standard8 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard8 pagesEnglish languagesale 10% offe-Library read for1 day
Requirements and methods of test for the construction and performance of fire hose reel systems with lay-flat hose for installation in buildings and other construction works, permanently connected to a water supply for use by the occupants
- Draft25 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements and methods of test for the construction and performance of fire hose systems with lay-flat hose for installation in buildings and other construction works, permanently connected to a water supply, for use by the occupants.
Its requirements may apply in general for other applications, for example in marine applications or in aggressive environments, but additional requirements may be necessary in such cases.
For convenience of application in conformity testing, the normative annexes of this standard are arranged so that annex A gives the sequence of testing for conformity assessment and annexes B, C, D and E are in the correct sequence for testing.
NOTE All pressures are gauge pressures and are expressed in megapascals. 1 MPa = 10 bar.
- Standard24 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements and methods of test for the construction and performance of fire hose reel systems with semi-rigid hose for installation in buildings and other construction works, permanently connected to a water supply, for use by the occupants.
Its requirements may apply in general for other applications, for example in marine applications or in aggressive environments, but additional requirements may be necessary in such cases.
This standard is applicable to both manual and automatic fire hose reels for installation with and without cabinets.
For convenience of application in conformity testing, the normative annexes of this standard are arranged so that annex A gives the sequence of testing for conformity assessment and annexes B, C, D, E and F are in the correct sequence for testing.
NOTE All pressures are gauge pressures and are expressed in megapascals. 1 MPa = 10 bar.
- Standard27 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard gives recommandations for inspection and maintenance hosereels and hose systems such that they continue to provide the service for which they were manufactured, supplied or installed i.e. to ensure a first emergency intervention to fight a fire before more powerful means can be implemented. This standard is applicable to hose reel and hose system installations in all types of buildings irrespective of the nature of use of the buildings.
- Standard5 pagesEnglish languagesale 10% offe-Library read for1 day
TC - Correction in German Annex C
- Corrigendum2 pagesGerman languagesale 10% offe-Library read for1 day