CEN/TC 107/WG 10 - Flexible pipe systems for district heating
Functional requirements and test for flexible preinsulated directly buried district heating pipe systems. Operating temperatures 70°C up to 150°C and operating pressure 6 bar up to 25 bar.
Flexible pipe systems for district heating
Functional requirements and test for flexible preinsulated directly buried district heating pipe systems. Operating temperatures 70°C up to 150°C and operating pressure 6 bar up to 25 bar.
General Information
This document specifies classification, general requirements and test methods for flexible, factory made, buried district heating pipe systems with thermoplastic reinforced service pipes (TRSP).
The factory made bonded or non-bonded flexible pipe systems, covered by this document, consists of:
- Thermoplastic reinforced service pipe, which consists of an inner layer made of PE-Xa, a thermoplastic intermediate layer, a reinforcement layer made of para-aramid fibres, an outer thermoplastic layer and a diffusion barrier layer, all with bonded structure;
- Thermal insulation layer;
- Casing made of PE.
Depending on the temperature profile, this document is applicable to a maximum operating temperature of 115 °C and maximum operating design pressure up to 1,6 MPa.
The pipe systems are designed for a service life of at least 30 years.
This document does not apply to cover surveillance systems.
NOTE For higher temperatures or for the transport of other fluids, for example potable water, additional requirements and testing is needed. Such requirements are not specified in this document.
A guideline for testing the pipe assembly is given in Annex D.
- Technical specification26 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies requirements and test methods for flexible, factory made, buried district heating pipe systems with plastic service pipes and no bonding between the layers of the pipe assemblies.
It is only applicable in conjunction with EN 17878-1.
This document is applicable to pipes, fittings, their joints and to joints with components made of non-plastics materials intended to be used for district heating installations.
This document is applicable to a maximum operating temperature of 80 °C and maximum operating design pressure up to 1,0 MPa for a design service life of at least 50 years.
This document does not apply to cover surveillance systems.
NOTE For higher temperatures or for the transport of other fluids, for example potable water, additional requirements and testing are needed. Such requirements are not specified in this document.
- Standard17 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies classification, general requirements and test methods for flexible, factory made, buried district heating pipe systems.
This document is intended to be used only in conjunction with EN 17878-2 or EN 17878-3, as applicable.
This document is applicable to a maximum operating temperature of 80 °C and a maximum operating design pressure up to 1,0 MPa.
The pipe systems are designed for a service life of at least 50 years. For pipe systems with plastic service pipes, the respective temperature profiles are specified in EN 17878-2:2024 and EN 17878-3:2024.
For the transport of other liquids, for example potable water, additional requirements can be applicable.
- Standard29 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies requirements and test methods for flexible, factory made, buried district heating pipe systems with plastic service pipes and bonding between the layers of the pipe assemblies.
It is only applicable in conjunction with EN 17878-1.
This document is applicable to pipes, fittings, their joints and to joints with components made of non-plastics materials intended to be used for district heating installations.
This document is applicable to a maximum operating temperature of 80 °C and maximum operating design pressure up to 1,0 MPa for a design service life of at least 50 years.
This document does not apply to cover surveillance systems.
NOTE For higher temperatures or for the transport of other fluids, for example potable water, additional requirements and testing are needed. Such requirements are not specified in this document.
- Standard18 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies classification, general requirements and test methods for flexible, factory made, buried district heating pipe systems.
This document is intended to be used in conjunction with part 2, 3 or 4, as applicable.
Depending on the pipe assembly (see Table 4), this document is applicable to a maximum operating temperature of 95 °C (part 2 and 3) and a maximum operating temperature of 120 °C (for part 4) and design pressures of 0,6 MPa to 2,5 MPa.
The pipe systems are designed for a service life of at least 30 years. For pipe systems with plastic service pipes, the respective temperature profiles are specified in EN 15632-2 and EN 15632-3.
NOTE For the transport of other liquids, for example potable water, additional requirements can be applicable.
- Standard32 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies requirements and test methods for flexible, factory made, buried district heating pipe systems with plastic service pipes and no bonding between the layers of the pipe assemblies.
It is only applicable in conjunction with part 1.
This document is applicable to pipes, fittings, their joints and to joints with components made of non-plastics materials intended to be used for district heating installations.
This document is applicable to a maximum operating temperature of 95 °C and maximum operating design pressure up to 1,0 MPa for a design service life of at least 30 years.
This document does not apply to cover surveillance systems.
NOTE For higher temperatures or for the transport of other fluids, for example potable water, additional requirements and testing is needed. Such requirements are not specified in this document.
- Standard18 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies requirements and test methods for flexible, factory made, buried district heating pipe systems with plastic service pipes and bonding between the layers of the pipe assemblies.
It is only applicable in conjunction with part 1.
This document is applicable to pipes, fittings, their joints and to joints with components made of non-plastics materials intended to be used for district heating installations.
This document is applicable to a maximum operating temperature of 95 °C and maximum operating design pressure up to 1,0 MPa for a design service life of at least 30 years.
This document does not apply to cover surveillance systems.
NOTE For higher temperatures or for the transport of other fluids, for example potable water, additional requirements and testing is needed. Such requirements are not specified in this document.
- Standard20 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies requirements and test methods for flexible, factory made, buried district heating pipe systems with metallic service pipes and bonding between the layers of the pipe assemblies and thermal insulation materials of polyurethane or polyisocyanurate foam, the casing being made of polyethylene.
It is only applicable in conjunction with part 1.
This document is applicable to pipes, fittings, their joints and to joints with components made of non-plastics materials intended to be used for district heating installations.
This document is applicable to a continuous operating temperature up to 120 °C and a maximum operating temperature of 140 °C for maximum 300 h/a, and a design pressure up to 2,5 MPa for a design service life of at least 30 years.
This document does not apply to cover surveillance systems.
NOTE For higher temperatures or for the transport of other fluids, for example potable water, additional requirements and testing is needed. Such requirements are not specified in this document.
- Standard14 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard provides requirements and test methods for flexible, pre-insulated, directly buried heating pipes with plastics service pipes and bonding between the layers of the pipes.
This European Standard is valid for maximum operating temperatures of 95 °C and maximum operating pressures up to 10 bar for a design lifetime of at least 30 years.
This European Standard does not cover surveillance systems.
NOTE For higher temperatures or for the transport of other fluids, for example potable water, additional requirements and testing is needed. Such requirements are not specified in this European Standard.
- Standard12 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard provides classification, general requirements and test methods for flexible, pre-insulated, directly buried district heating pipe systems.
It is intended to be used in conjunction with parts 2, 3, 4, and 5.
Depending on the pipe assembly (see Table 4), this European Standard is valid for maximum operating temperatures of 95 °C to 140 °C and operating pressures of 6 bar to 25 bar.
The pipe systems are designed for a lifetime of 30 years. For pipe systems with plastic service pipes, the respective temperature profiles are defined in EN 15632-2 and EN 15632-3.
NOTE For the transport of other liquids, for example potable water, additional requirements may be applicable.
- Standard31 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard provides requirements and test methods for flexible, pre-insulated, direct buried district heating pipes with plastic service pipes and no bonding between the layers of the pipes.
This European Standard is valid for maximum operating temperatures of 95 °C and maximum operating pressures up to 10 bar for a design lifetime of at least 30 years.
This European Standard does not cover surveillance systems.
NOTE For higher temperatures or for the transport of other fluids, for example potable water, additional requirements and testing is needed. Such requirements are not specified in this European Standard.
- Standard9 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard provides requirements and test methods for flexible, pre-insulated, directly buried district heating pipe assemblies with metallic service pipes and bonding between the layers of the pipes and thermal insulation materials of polyurethane or polyisocyanurate foam. Casing pipe shall be made from polyethylene.
This European Standard is valid for maximum operating temperatures up to 140 °C and pressures up to 25 bar for a design lifetime of at least 30 years.
NOTE For higher temperatures or for the transport of other fluids, for example potable water, additional requirements and testing is needed. Such requirements are not specified in this European Standard.
- Standard9 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard provides requirements and test methods for flexible, pre-insulated, directly buried heating pipes with plastics service pipes and bonding between the layers of the pipes.
This European Standard is valid for maximum operating temperatures of 95 °C and maximum operating pressures up to 10 bar for a design lifetime of at least 30 years.
This European Standard does not cover surveillance systems.
NOTE For higher temperatures or for the transport of other fluids, for example potable water, additional requirements and testing is needed. Such requirements are not specified in this European Standard.
- Standard11 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard provides requirements and test methods for flexible, pre-insulated, direct buried district heating pipes with plastic service pipes and no bonding between the layers of the pipes.
This European Standard is valid for maximum operating temperatures of 95 °C and maximum operating pressures up to 10 bar for a design lifetime of at least 30 years.
This European Standard does not cover surveillance systems.
NOTE For higher temperatures or for the transport of other fluids, for example potable water, additional requirements and testing is needed. Such requirements are not specified in this European Standard.
- Standard9 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard provides classification, general requirements and test methods for flexible, pre-insulated, directly buried district heating pipe systems.
It is intended to be used in conjunction with parts 2, 3, 4, and 5.
Depending on the pipe assembly (see Table 4), this European Standard is valid for maximum operating temperatures of 95 °C to 140 °C and operating pressures of 6 bar to 25 bar.
The pipe systems are designed for a lifetime of 30 years. For pipe systems with plastic service pipes, the respective temperature profiles are defined in EN 15632-2 and EN 15632-3.
NOTE For the transport of other liquids, for example potable water, additional requirements may be applicable.
- Standard28 pagesEnglish languagesale 10% offe-Library read for1 day