CEN/TC 236 - Non industrial manually operated shut-off valves for gas and particular combinations valves-other products
Standardization of the requirements for fitness for purpose (for design, performance, testing, marking, packing, instructions for installation and use) of manually operated shut-off valves for domestic and commercial not directly buried installations inside or outside of buildings, and other particular types of valves strictly combined to particular products or component considered as a whole (e.g. safety flexible metallic hose assemblies and connection valves for domestic gas appliances).
Non industrial manually operated shut-off valves for gas and particular combinations valves-other products
Standardization of the requirements for fitness for purpose (for design, performance, testing, marking, packing, instructions for installation and use) of manually operated shut-off valves for domestic and commercial not directly buried installations inside or outside of buildings, and other particular types of valves strictly combined to particular products or component considered as a whole (e.g. safety flexible metallic hose assemblies and connection valves for domestic gas appliances).
General Information
1.1 This European Standard specifies the characteristics for the construction, performance and safety of ball valves and closed bottom taper plug valves. It also details the test methods and marking provisions.
It applies to metallic valves not directly buried for domestic and commercial installations inside or outside of buildings, using gases of the first, second and third family (specified in EN 437) and working up to 0,2 × 105 Pa, 0,5 × 105 Pa, 1 × 105Pa, 5 × 105 Pa and 20 × 105Pa and with temperature limits from -5 °C or −20 °C to + 60 °C.
NOTE "Not directly buried" within the context of this standard means that valves below ground are not in direct contact with earth or other materials e.g. that they are in a protected encasement.
1.2 Valve nominal sizes (DN) covered by this European Standard are as follows: 6, 8, 10, 12, 15, 20, 25, 32, 40, 50, 65, 80, 100.
- Standard45 pagesEnglish languagesale 10% offe-Library read for1 day
These valves are suitable for connection of the fixed gas supply system to domestic appliances inside or outside a dwelling using 2nd or 3rd Family gases and at a pressure of up to and including 0,5 bar.
These valves are designed for the use with either movable appliances or for the connection of fixed appliances.
- Standard67 pagesEnglish languagesale 10% offe-Library read for1 day
Replace the second paragraph of clause 1.1 with the following:
"It applies to metallic valves for domestic and commercial not directly buried installations inside or outside of buildings, using gases of the first, second and third family (specified in EN 437) and working up to 0,2 ´ 105 Pa, 0,5 ´ 105 Pa and 5 ´ 105 Pa."
- Amendment30 pagesEnglish languagesale 10% offe-Library read for1 day
1.1 This European standard specifies the general requirements for the construction, performance and safety of ball valves and closed bottom taper plug valves. It also details the test methods and marking requirements. It applies to valves for domestic and commercial not directly buried installations inside or outside of buildings, using gases of the first, second and third family (specified in EN 437).
- Standard28 pagesEnglish languagesale 10% offe-Library read for1 day