This document specifies the special provisions and safety rules describing the behaviour of lifts in the event of fire in a building, on the basis of a recall signal(s) to the lift(s) control system.
This document applies to new passenger lifts and goods passenger lifts with all types of drives. However, it may be used as a basis to improve the safety of existing passenger and goods passenger lifts.
This document does not apply to:
-   lifts that remain in use in the event of fire, e.g. firefighters lifts as defined in EN 81-72:2020,
-   lifts used for the evacuation of a building.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1   This document specifies the additional or deviating requirements to EN 81-20:2020 for new passenger and goods passenger lifts, which can be used for firefighting and evacuation purposes under firefighters control.
1.2   This document applies, when the following conditions are fulfilled:
-   the lift well and the lift environment are designed to restrict the ingress of fire, heat and smoke to the lift well, machinery spaces and safe areas;
-   the building design limits the flow of water into the lift well;
-   the firefighters lift is not used as an escape route;
-   the lift well and the lift environment are fire protected for at least to the same level as the building structure;
-   the power supply is secure and reliable;
-   the electrical cable(s) providing power to the lift is fire protected to the same fire protection level as given to the lift well structure;
-   a suitable maintenance and verification plan is implemented.
1.3   This document does not cover:
-   the use of lifts with partially enclosed wells for use as firefighters lifts;
-   lifts installed in new or existing buildings, which are not included in fire resisting building structure;
-   important modification to existing lifts.
1.4   This document does not define:
-   the number of firefighters lifts and the floors to be served during firefighting operations;
-   size of safe area(s);
-   the use of other than the highest deck of a multi deck lift for firefighting operations.
1.5   This document deals with the significant hazards, hazardous situations and events relevant to firefighters lifts (as listed in Clause 4) when they are used as intended and under the conditions as foreseen by the installer.
1.6   The following significant hazards are not dealt with in this document and are assumed to be addressed by the building designer:
-   not having enough or correctly located firefighters lifts to move the firefighters up the building;
-   a fire in the firefighters lift well, safe area, machinery space or car;
-   the absence of building floor identification signs at any floor;
-   water management is not operating correctly.

  • Standard
    46 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    51 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the fire resistance requirements for lift landing doors which are intended to provide a barrier to the spread of fire from the landing side and via the lift well in buildings during a defined period of time. The fire resistance requirements are expressed in terms of integrity (E), insulation (EI) and radiation (EW).
It is applicable to lift landing doors installed in the lift well openings at landings and used as means of access to lift car.
It also specifies the method of testing and classification of fire resistance of lift landing doors. The test method is only valid for furnaces where the door is mounted in a vertical position. The test method specifies the measurement of integrity and if required the measurement of radiation and thermal insulation.
This document does not cover other technical requirements in addition to fire resistance requirements.
This document refers to CO2 as means of tracing the propagation of fire. The document does not cover hazards due to emission of gases.
This document is not applicable to lifts which are installed before the date of its publication.

  • Standard
    34 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    33 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1   Use of the lift
This Technical Specification gives rules for the intended use of the lift by persons with impaired mobility in order to assist the evacuation of a building. To achieve this objective, the selected lift(s) must be incorporated within an overall building design that includes all the usual stairs and escape routes without any reduction in their quantity or capacity.
It specifies the special provisions and safety rules to assist persons with impaired mobility to safely evacuate a building using lifts in relative safety with the help of suitably trained assistants.
This specification does not define the number and size of lift required, or the size of door openings that must be determined on a case by case basis by the building designer in line with applicable national regulations.
1.2   This Technical Specification applies
To permanently installed new:
a)   electric lifts, with traction or positive drive (as defined in EN 81-1);
b)   hydraulic lifts (as defined in EN 81-2).
1.3   This Technical Specification defines requirements to allow safe lift use where
a)   the buildings has not sustained structural damage e.g. from explosion, flood, lightening strike, earthquake, storm etc.
b)   the well and car is safe for persons to use. e.g. free of smoke, etc.
c)   a fire resisting structure for the lift provides suitable protection;
d)   some form of fire detection means is provided at least at the lift and safe areas;
e)   where power supplies are secure and reliable, the provision of a secondary supply is not essential but the cable providing power to the lift shall be fire protected to the same level as given to the lift structure;
f)   where a building secondary supply is not provided, the lift shall have a provision to allow the lift to be recovered electrically to an adjacent safe area (floor).
1.4   Assumptions
The following assumptions are made:
a)   The lift is provided with a means to protect it from the effects of fire and smoke.
(....)

  • Technical specification
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the additional requirements to EN 81-20:2020 for passenger and goods passenger lifts, which can be used to support faster evacuation of persons with disabilities and persons with walking difficulties, including in case of fire alarm.
This document does not apply to:
-   lifts installed into buildings which are not in accordance with Annex C;
-   lifts for evacuation due to circumstances which introduce other hazards such as explosion threat, chemical or biological attack, flooding, storm damage, or earthquake. In these cases, this document can be used as a basis with further measures as required from risk assessment.
The following significant hazards are out of the scope of this document (see Table 2):
-   fire or smoke in the evacuation lift well, safe areas or machinery spaces;
-   ingress of water to the lift well during evacuation process;
-   insufficient or incorrectly located evacuation lifts;
-   insufficient evacuation capacity;
-   entrapment in waiting area (safe area) due to absence of lift service or adjacent stairs;
-   structural collapse or failure of building services (including public supply network, lighting, ventilation) before the evacuation using lifts has been completed;
-   presence of harmful gases, potentially explosive atmosphere, extreme climate conditions, transport of dangerous goods.

  • Draft
    38 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the additional requirements to EN 81-20:2020 for passenger and goods passenger lifts, which can be used to support faster evacuation of persons with disabilities and persons with walking difficulties, including in case of fire alarm.
This document does not apply to:
-   lifts installed into buildings which are not in accordance with Annex C;
-   lifts for evacuation due to circumstances which introduce other hazards such as explosion threat, chemical or biological attack, flooding, storm damage, or earthquake. In these cases, this document can be used as a basis with further measures as required from risk assessment.
The following significant hazards are out of the scope of this document (see Table 2):
-   fire or smoke in the evacuation lift well, safe areas or machinery spaces;
-   ingress of water to the lift well during evacuation process;
-   insufficient or incorrectly located evacuation lifts;
-   insufficient evacuation capacity;
-   entrapment in waiting area (safe area) due to absence of lift service or adjacent stairs;
-   structural collapse or failure of building services (including public supply network, lighting, ventilation) before the evacuation using lifts has been completed;
-   presence of harmful gases, potentially explosive atmosphere, extreme climate conditions, transport of dangerous goods.

  • Draft
    44 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the method of test for determining the fire resistance of lift landing doors which may be exposed to a fire from the landing side. The procedure applies to all types of lift landing doors used as a means of access to lifts in buildings and which are intended to provide a fire barrier to the spread of fire via the lift well.
The procedure allows for the measurement of integrity and if required the measurement of radiation and thermal insulation.
No requirements other than the verification that the specimen is operational are included for mechanical conditioning before the test as these are included in the relevant product standard.

  • Standard
    33 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the special provisions and safety rules describing the behaviour of lifts in the event of fire in a building, on the basis of a recall signal(s) to the lift(s) control system.
This European Standard applies to new passenger lifts and goods passenger lifts with all types of drives. However, it may be used as a basis to improve the safety of existing passenger and goods passenger lifts.
This European Standard does not apply to
-   lifts that remain in use in the event of fire e.g. firefighters lifts as defined in EN 81 72,
-   lifts used for the evacuation of a building.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1   This European Standard specifies the additional or deviating requirements to EN 81-20 for new passenger and goods passenger lifts, which may be used for firefighting and evacuation purposes under firefighters control.
1.2   This European Standard applies, when the following conditions are fulfilled:
-   the lift well and the lift environment are designed to restrict the ingress of fire, heat and smoke to the lift well, machinery spaces and safe areas;
-   the building design limits the flow of water into the lift well;
-   the firefighters lift is not an escape route, such as staircases;
-   the lift well and the lift environment are fire protected for at least to the same level as the building structure;
-   the power supply is secure and reliable;
-   the electrical cable providing power to the lift is fire protected to the same fire protection level as given to the lift well structure;
-   a suitable maintenance and verification plan is implemented.
1.3   This European Standard does not cover:
-   the use of lifts with partially enclosed wells for use as firefighters lifts;
-   lifts installed in new or existing buildings, which are not included in fire resisting building structure;
-   important modification to existing lifts.
1.4   This European Standard does not define:
-   the number of firefighters lifts and the floors to be served during firefighting operations;
-   size of safe area(s);
-   the use of other than the highest deck of a multi deck lift for firefighting operations.
1.5   This European Standard deals with the significant hazards, hazardous situations and events relevant to firefighters lifts (as listed in Clause 4) when they are used as intended and under the conditions as foreseen by the installer.
1.6   The following significant hazards are not dealt with in this standard and are assumed to be addressed by the building designer:
-   not having enough or correctly located firefighters lifts to move the firefighters up the building;
-   a fire in the firefighters lift well, safe area, machinery space or car;
-   the absence of building floor identification signs at any floor;
-   water management is not operating correctly.

  • Standard
    47 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the special provisions and safety rules to ensure the behaviour of lifts in the event of fire in a building, on the basis of a signal(s) from the fire alarm detection system to the lift(s) control system.
It applies to new passenger lifts and goods passenger lifts. However, it may be used as a basis to improve the safety of existing passenger and goods passenger lifts.
This standard gives various options for control of the lift in the event of a fire in a building.
This standard does not apply to:
¾   lifts which remain in use in the event of fire e.g. firefighters' lifts as defined in EN 81-72:2003;
¾   the use of lifts for the evacuation of a building and
¾   a fire in the well.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day