1.1   This European Standard deals with safety requirements for construction, manufacturing, installation, maintenance and dismantling of electrically operated stairlifts (chair, standing platform and wheelchair platform) affixed to a building structure, moving in an inclined plane and intended for use by persons with impaired mobility:
-   travelling over a stair or an accessible inclined surface;
-   intended for use by one person;
-   whose carriage is directly retained and guided by a guide rail or rails;
-   supported or sustained by rope (5.4.4), rack and pinion (5.4.5), chain (5.4.6), friction traction drive (5.4.7), and guided rope and ball (5.4.8).
1.2   The standard identifies hazards as listed in Clause 4 which arise during the various phases in the life of such equipment and describes methods for the elimination or reduction of these hazards when used as intended by the manufacturer.
1.3   This European standard does not specify the additional requirements for:
-   operation in severe conditions (e.g. extreme climates, strong magnetic fields);
-   operation subject to special rules (e.g. potentially explosive atmospheres);
-   handling of materials the nature of which could lead to dangerous situations;
-   use of energy systems other than electricity;
-   hazards occurring during manufacture;
-   earthquakes, flooding, fire;
-   evacuation during a fire;
-   stairlifts for goods only;
-   concrete, hardcore, timber or other foundation or building arrangement;
-   design of anchorage bolts to the supporting structure.
NOTE   For the actual type of machinery, noise is not considered a significant nor relevant hazard.
1.4   This document is not applicable to power operated stairlifts which are manufactured before the date of publication of this document by CEN.

  • Standard
    81 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the special provisions and safety rules for passenger and goods passenger lifts where these lifts are permanently installed in buildings that are in compliance with EN 1998-1 (Eurocode 8).
This standard defines additional requirements to EN 81 1 and EN 81 2.
It applies to new passenger lifts and goods passenger lifts. However, it may be used as a basis to improve the safety of existing passenger and goods passenger lifts.
It does not apply to seismic lift category 0 as defined in Table A.1.
This European Standard does not address other risks due to seismic events (for example fire, flood, explosion).

  • Standard
    30 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the special provisions and safety rules for passenger and goods passenger lifts where these lifts are permanently installed in buildings that are in compliance with EN 1998-1 (Eurocode 8).
This document defines additional requirements to EN 81-20 and EN 81-50.
It applies to new passenger lifts and goods passenger lifts. However, it can be used as a basis to improve the safety of existing passenger and goods passenger lifts.
This document does not introduce any additional special provisions and safety rules for lifts which are in Seismic lift category 0 as defined in Annex A, Table A.1.
This document does not address other risks due to seismic events (e.g. fire, flood, explosion).

  • Standard
    30 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This draft European Standard specifies the method of test for determining the fire resistance of lift landing doors which may be exposed to a fire from the landing side. The procedure applies to all types of lift landing doors used as a means of access to lifts in buildings and which are intended to provide a fire barrier to the spread of fire via the lift well.
The procedure allows for the measurement of integrity and if required the measurement of radiation and thermal insulation.
No requirements other than the verification that the specimen is operational are included for mechanical conditioning before the test as these are included in the relevant product standard.

  • Standard
    33 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the method of test for determining the fire resistance of lift landing doors which may be exposed to a fire from the landing side. The procedure applies to all types of lift landing doors used as a means of access to lifts in buildings and which are intended to provide a fire barrier to the spread of fire via the lift well.
The procedure allows for the measurement of integrity and if required the measurement of radiation and thermal insulation.
No requirements other than the verification that the specimen is operational are included for mechanical conditioning before the test as these are included in the relevant product standard.

  • Standard
    33 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1   This European Standard specifies the safety rules for the construction and installation of permanently installed new electric lifts, with traction or positive drive, serving defined landings levels, having a vehicle designed to convey passengers or passengers and loads, suspended by ropes or chains and travelling in a vertical plan along guide rails that are inclined at an angle of between 15° and 75° in relation to the horizontal.
1.2   In addition to the requirements of this standard, supplementary requirements should be considered in special cases (potentially explosive atmosphere, extreme climate conditions, seismic conditions, transporting dangerous goods, etc.).
1.3   This European Standard does not cover:
a)   lifts with drives other than those stated in 1.1;
b)   installation of electric lifts in existing buildings to the extent that space does not permit;
c)   important modifications (see Annex E) to a lift installed before this standard is brought into application;
d)   lifting appliances, such as paternosters, mine lifts, theatrical lifts, appliances with automatic caging, skips, lifts and hoists for building and public works sites, ships' hoists, platforms for exploration or drilling at sea, construction and maintenance appliances;
e)   safety during transport, installation, repairs, and dismantling of lifts;
f)   lifts with rated speed ≤ 0,15 m/s.
However, this standard may usefully be taken as a basis.
Noise is not dealt with in this standard because it is not relevant to the safe use of the lift.
Vibrations are dealt with for electric parts only. Direct effects on human bodies are not considered as harmful.
1.4   This European Standard does not specify the additional requirements necessary for the use of lifts in case of fire.
1.5   Taking into account the state of art, the scope of the present standard is limited as follows:
-   inclination: a variation in inclination is permitted for the travel path;
-   travel path: confined within the vertical plane;
-   maximum capacity of the car: 7 500 kg (100 passengers);
-   maximum rated speed (v): 4 m/s.
Both characteristics (capacity and speed) are linked by the relation given in the following Figure 1.
(...)
The standard applies to all the constituent components of the lift including: running tracks, guides, safety gear operating device, counter-rails, but excludes the supporting structures, civil engineering structures and anchorages that are dealt with by other regulations.
1.6   This standard is not applicable for inclined lifts which are manufactured before the date of its publication as EN.

  • Standard
    207 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the immunity performance criteria and test levels for apparatus used in lifts, escalators and moving walks which are intended to be permanently installed in buildings including the basic safety requirements in regard to their electromagnetic environment. These levels represent essential EMC requirements. The standard refers to EM conditions as existing in residential, office and industrial buildings. This standard addresses commonly known EMC related hazards and hazardous situations relevant to lifts, escalators and moving walks when they are used as intended and under the conditions foreseen by the lift installer or escalator and/or moving walk manufacturer. This standard addresses the environmental conditions stated in the EN 81 series of standards and EN 115 series (humidity, temperature, etc.), so far as they are related to EMC performance. However: - performance criteria and test levels for apparatus/assembly of apparatus used in general function circuits do not cover situations with an extremely low probability of occurrence; - this standard does not apply to other apparatus already proven to be in conformity to the EMC Directive, and not related to the safety of the lift, escalator or moving walk, such as lighting apparatus, communication apparatus, etc. This standard does not apply to electromagnetic environments such as: - radio transmitter stations; - railways and metros; - heavy industrial plant; - electricity power stations which need additional investigations.

  • Standard
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1   This European Standard specifies the immunity performance criteria and test levels for apparatus used in lifts, escalators and moving walks which are intended to be permanently installed in buildings including the basic safety requirements in regard to their electromagnetic environment. These levels represent essential EMC requirements.
The standard refers to EM conditions as existing in residential, office and industrial buildings.
This standard addresses commonly known EMC related hazards and hazardous situations relevant to lifts, escalators and moving walks when they are used as intended and under the conditions foreseen by the lift installer or escalator and/or moving walk manufacturer.
However:
-   performance criteria and test levels for apparatus/assembly of apparatus used in general function circuits do not cover situations with an extremely low probability of occurrence;
-   this standard does not apply to other apparatus already proven to be in conformity to the EMC Directive, and not related to the safety of the lift, escalator or moving walk, such as lighting apparatus, communication apparatus, etc.
1.2   This European Standard does not apply to electromagnetic environments such as:
-   radio-transmitter stations,
-   railways and metros,
-   heavy industrial plant,
-   electricity power station,
which need additional investigations.
1.3   This standard is not applicable to apparatus which were manufactured before the date of its publication as EN 12016.

  • Standard
    24 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1 This European standard deals with safety requirements for construction, manufacturing, installation and maintenance of electrically operated vertical lifting platforms affixed to a building structure intended for use by persons with impaired mobility :
- travelling vertically between fixed levels along a guided path within 15 degrees max. of the vertical;
- intended for use is by persons with or without a wheelchair ;
- supported or sustained by wire rope, chain, rack and pinion, hydraulic jack (direct or indirect), screw and nut, guided chain, friction/traction, or scissors mechanism ;
- with enclosed lift-ways ;
- with rated speed not exceeding 0,15 m/s even after installation ;
- with hold-to-run control.
1.2 This standard deals with all significant hazards relevant to lifting platforms, when they are used as intended and under the conditions foreseen by the manufacturer (see clause 4).
1.3 This European standard does not specify the additional requirements for :
- operation in severe conditions (e.g. extreme climates, strong magnetic fields) ;
- lightning protection ;
- operation subject to special rules (e.g. potentially explosive atmospheres) ;
- handling of materials, the nature of which could lead to dangerous situations ;
- hazards occurring during manufacture ;
- earthquakes, flooding ;
- fire fighting, evacuation during a fire ;
- noise and vibrations ;
- concrete, hardcore, timber or other foundation or building arrangement ;
- the design of anchorage bolts to the supporting structure ;
- type C wheelchairs as defined in EN 12183 and/or EN 12184.

  • Standard
    94 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1   This European Standard deals with safety requirements for construction, manufacturing, installation, maintenance and dismantling of electrically powered vertical lifting platforms affixed to a building structure intended for use by persons with impaired mobility:
-   travelling vertically between predefined levels along a guided path whose inclination to the vertical does not exceed 15°;
-   intended for use by persons with or without a wheelchair;
-   supported or sustained by rack and pinion, wire ropes, chains, screw and nut, friction/traction between wheels and the rail, guided chain, scissors mechanism or hydraulic jack (direct or indirect);
-   with enclosed liftways;
-   with a speed not greater than 0,15 m/s;
-   with platforms where the carrier is not completely enclosed
1.2   This standard deals with all significant hazards relevant to lifting platforms, when they are used as intended and under the conditions foreseen by the manufacturer (see Clause 4).
1.3   This European Standard does not specify the additional requirements for:
-   operation in severe conditions (e.g. extreme climates, strong magnetic fields);
-   lightning protection;
-   operation subject to special rules (e.g. potentially explosive atmospheres);
-   handling of materials, the nature of which could lead to dangerous situations;
-   vertical lifting platforms whose primary function is the transportation of goods;
-   vertical lifting platforms whose carriers are completely enclosed;
-   vertical lifting platforms prone to vandalism;
-   hazards occurring during manufacture;
-   earthquakes, flooding;
-   fire fighting, evacuation and behaviour during a fire;
-   noise and vibrations;
-   the design of concrete, hardcore, timber or other foundation or building arrangement;
-   the design of anchorage bolts to the supporting structure;
-   type C wheelchairs as defined in prEN 12183 and/or prEN 12184.
(....)

  • Standard
    94 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard deals with safety requirements for construction, manufacturing, installation, maintenance and dismantling of electrically operated stairlifts (chair, standing platform and wheelchair platform) affixed to a building structure, moving in an inclined plane and intended for use by persons with impaired mobility: - travelling over a stair or an accessible inclined surface; - intended for use by one person; whose carriage is directly retained and guided by a guide rail or rails; - supported or sustained by rope (5.4.4), rack and pinion (5.4.5), chain (5.4.6), screw and nut (5.4.7), friction traction drive (5.4.8), and guided rope and ball (5.4.9). The standard identifies hazards as listed in Clause 4 which arise during the various phases in the life of such equipment and describes methods for the elimination or reduction of these hazards when used as intended by the manufacturer. This European standard does not specify the additional requirements for: - operation in severe conditions (e.g. extreme climates, strong magnetic fields ); - lightning protection; - operation subject to special rules (e.g. potentially explosive atmospheres); - handling of materials the nature of which could lead to dangerous situations; - use of energy systems other than electricity; - hazards occurring during manufacture; earthquakes, flooding, fire; - type C wheelchairs as defined in EN 12183 and/or EN 12184;- evacuation during a fire; stairlifts for goods only; - concrete ,hardcore, timber or other foundation or building arrangement; - design of anchorage bolts to the supporting structure.

  • Standard
    66 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the elements necessary for the preparation of the instructions for the maintenance operations, as in 3.1, which are provided for new installed passenger lifts, goods passenger lifts, accessible goods only lifts, service lifts, escalators and passenger conveyors.
This European Standard does not cover:
a) instructions for the installation and the dismantling;
b) any legal examinations and tests based on national regulations.
Existing installations are not covered by this Standard, but it can be taken as a reference.

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the elements necessary for the preparation of the instructions for the maintenance operations, as in 3.1, which are provided for new installed passenger lifts, goods passenger lifts, accessible goods only lifts, service lifts, escalators and passenger conveyors.
This European Standard does not cover:
a) instructions for the installation and the dismantling;
b) any legal examinations and tests based on national regulations.
Existing installations are not covered by this Standard, but it can be taken as a reference.

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1   This document deals with safety requirements for construction, manufacturing, installation, maintenance and dismantling of electrically operated stairlifts (chair, standing platform and wheelchair platform) affixed to a building structure, moving in an inclined plane and intended for use by persons with impaired mobility:
-   travelling over a stair or an accessible inclined surface;
-   intended for use by one person;
-   whose carriage is directly retained and guided by a guide rail or rails;
-   supported or sustained by rope (5.4.4), rack and pinion (5.4.5), chain (5.4.6), friction traction drive (5.4.7), and guided rope and ball (5.4.8).
1.2   This document identifies hazards as listed in Clause 4 which arise during the various phases in the life of such equipment and describes methods for the elimination or reduction of these hazards when used as intended by the manufacturer.
1.3   This document does not specify the additional requirements for:
-   operation in severe conditions (e.g. extreme climates, strong magnetic fields);
-   operation subject to special rules (e.g. potentially explosive atmospheres);
-   handling of materials, the nature of which could lead to dangerous situations;
-   use of energy systems other than electricity;
-   hazards occurring during manufacture;
-   earthquakes, flooding, fire;
-   evacuation during a fire;
-   stairlifts for goods only;
-   concrete, hardcore, timber or other foundation or building arrangement;
-   design of anchorage bolts to the supporting structure.
NOTE   For the actual type of machinery, noise is not considered a significant nor relevant hazard.
1.4   This document is not applicable to power operated stairlifts which are manufactured before the date of publication of this document by CEN.

  • Standard
    81 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European standard specifies the requirements for the accessibility of new lifts serving defined landing levels, having a car designed for the transportation of persons, and moving along guide rails inclined at an angle of more then 15degrees to the horizontal. NOTE: This standard may be used as guidance for upgrading existing lifts in line with the recommandation of the European Commission dated 8th of June, 1995 (95/216/EC) concerning improvements to safety of existing lifts. This European standard describes three sizes of lifts offering different levels of accessibility to wheelchair users.

  • Standard
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the fundamental characteristics of data logging and monitoring systems for lift, escalator and passenger conveyor installations.

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the fundamental characteristics of data logging and monitoring systems for lift, escalator and passenger conveyor installations.

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the elements necessary for the preparation of the instructions for the maintenance operations, as in 3.1, which are provided for new installed passenger lifts, goods passenger lifts, accessible goods only lifts, service lifts, escalators and passenger conveyors.
This European Standard does not cover:
a) instructions for the installation and the dismantling;
b) any legal examinations and tests based on national regulations.
Existing installations are not covered by this Standard, but it can be taken as a reference.

  • Draft
    26 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1 This standard specifies the safety rules for the construction and installation of permanently installed new electric lifts, with traction or positive drive, serving defined landings levels, having a vehicle designed to convey passengers or passengers and loads, suspended by ropes or chains and travelling in strait path along guide rails that are inclined at an angle of between 15° and 75° in relation to the horizontal.
1.2 In addition to the requirements of this standard, supplementary requirements shall be considered in special cases (potentially explosive atmosphere, extreme climate conditions, seismic conditions, transporting dangerous goods, etc.).
1.3   This standard does not cover:
a)   lifts with drives other than those stated in 1.1;
b)   installation of electric lifts in existing buildings 1) to the extent that space does not permit ;
c)   important modifications (see annex E) to a lift installed before this standard is brought into application ;
d)   lifting appliances, such as paternosters, mine lifts, theatrical lifts, appliances with automatic caging, skips, lifts and hoists for building and public works sites, ships' hoists, platforms for exploration or drilling at sea, construction and maintenance appliances ;
e)   installations with guide rail inclination to the horizontal greater than 75° or lower than 15°.
f)   safety during transport, installation, repairs, and dismantling of lifts.
g)   installations with curves in a horizontal plan.
h)   Lifts with rated speed ≤ 0.15 m/s.
However, this standard may usefully be taken as a basis.
Noise and vibrations are not dealt with in this standard because these are not relevant to the safe use of the lift.
1.4 This standard does not specify the additional requirements necessary for the use of lifts in case of fire.
1.5 The scope of this standard has been deliberately limited in view of the current state of the art to such moving devices as the following:
(...)

  • Draft
    241 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1 This standard specifies the safety rules for the construction and installation of permanently installed new rack and pinion lifts with the
drive unit attached to the car serving defined landing levels, having a car designed for the transportation of persons or persons and goods supported by rack and pinion and moving between guide rails inclined not more than 15° to the vertical. The maximum rated speed is 2 m/s.
1.2 In addition to the requirements of this standard supplementary requirements shall be considered in special cases (potentially explosive
atmosphere, extreme climate conditions, seismic conditions, transporting dangerous goods, etc.)
1.3 This standard does not cover:
a) lifts with drives other than those stated in 1.1;
b) installation of rack and pinion lifts in existing buildings1 to the extent that space does not permit;
c) important modifications (see annex E) to a lift installed before this standard is brought into application, and
d) lifting appliances, such as paternosters, mine lifts, theatrical lifts, appliances with automatic caging, skips, lifts and hoists for building and public works sites, ships hoists, platforms for exploration or drilling at sea, construction and maintenance appliances;
e) installations where the inclination of the guide rails to the vertical exceeds 15° ;
f) safety during transport, installation, repairs, and dismantling of lifts;
g) lifts with rated speed ≤ 0,15 m/s.
NOTE Exclusion mentioned under g) bases on the Machinery Directive 2006/42/EC Noise and vibrations are not dealt within this standard because these are not relevant to the safe use of the lift. However, this standard may usefully be taken as a basis.
1.4 This standard does not specify the additional requirements necessary for the use of lifts in case of fire.

  • Draft
    40 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies the emission limits in relation to electromagnetic disturbances and test conditions for lifts, escalators and moving walks, which are intended to be installed permanently in buildings.

  • Amendment
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies the emission limits in relation to electromagnetic disturbances and test conditions for lifts, escalators and moving walks, which are intended to be installed permanently in buildings.

  • Amendment
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1 This standard specifies the safety rules for the construction and installation of permanently installed new rack and pinion lifts with the
drive unit attached to the car serving defined landing levels, having a car designed for the transportation of persons or persons and goods supported by rack and pinion and moving between guide rails inclined not more than 15° to the vertical. The maximum rated speed is 2 m/s.
1.2 In addition to the requirements of this standard supplementary requirements shall be considered in special cases (potentially explosive
atmosphere, extreme climate conditions, seismic conditions, transporting dangerous goods, etc.)
1.3 This standard does not cover:
a) lifts with drives other than those stated in 1.1;
b) installation of rack and pinion lifts in existing buildings1 to the extent that space does not permit;
c) important modifications (see annex E) to a lift installed before this standard is brought into application, and
d) lifting appliances, such as paternosters, mine lifts, theatrical lifts, appliances with automatic caging, skips, lifts and hoists for building and public works sites, ships hoists, platforms for exploration or drilling at sea, construction and maintenance appliances;
e) installations where the inclination of the guide rails to the vertical exceeds 15° ;
f) safety during transport, installation, repairs, and dismantling of lifts;
g) lifts with rated speed ≤ 0,15 m/s.
NOTE Exclusion mentioned under g) bases on the Machinery Directive 2006/42/EC Noise and vibrations are not dealt within this standard because these are not relevant to the safe use of the lift. However, this standard may usefully be taken as a basis.
1.4 This standard does not specify the additional requirements necessary for the use of lifts in case of fire.

  • Draft
    40 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the elements necessary for the preparation of the instructions for the maintenance operations, as in 3.1, which are provided for new installed passenger lifts, goods passenger lifts, accessible goods only lifts, service lifts, escalators and moving walks.
This document does not cover:
a)   instructions for the installation and the dismantling;
b)   any legal examinations and tests based on national regulations.
Existing installations are not covered by this document, but it can be taken as a reference.

  • Draft
    26 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1 This standard specifies the safety rules for the construction and installation of permanently installed new electric lifts, with traction or positive drive, serving defined landings levels, having a vehicle designed to convey passengers or passengers and loads, suspended by ropes or chains and travelling in strait path along guide rails that are inclined at an angle of between 15° and 75° in relation to the horizontal.
1.2 In addition to the requirements of this standard, supplementary requirements shall be considered in special cases (potentially explosive atmosphere, extreme climate conditions, seismic conditions, transporting dangerous goods, etc.).
1.3   This standard does not cover:
a)   lifts with drives other than those stated in 1.1;
b)   installation of electric lifts in existing buildings 1) to the extent that space does not permit ;
c)   important modifications (see annex E) to a lift installed before this standard is brought into application ;
d)   lifting appliances, such as paternosters, mine lifts, theatrical lifts, appliances with automatic caging, skips, lifts and hoists for building and public works sites, ships' hoists, platforms for exploration or drilling at sea, construction and maintenance appliances ;
e)   installations with guide rail inclination to the horizontal greater than 75° or lower than 15°.
f)   safety during transport, installation, repairs, and dismantling of lifts.
g)   installations with curves in a horizontal plan.
h)   Lifts with rated speed ≤ 0.15 m/s.
However, this standard may usefully be taken as a basis.
Noise and vibrations are not dealt with in this standard because these are not relevant to the safe use of the lift.
1.4 This standard does not specify the additional requirements necessary for the use of lifts in case of fire.
1.5 The scope of this standard has been deliberately limited in view of the current state of the art to such moving devices as the following:
(...)

  • Draft
    241 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the minimum requirements for the safe and independent access and use of lifts by a wide range of persons, including persons with disabilities.
It is applicable to new passenger and goods passenger lifts according to EN 81 20. For other types of lifts, e.g. inclined lifts according to EN 81 22, this standard can usefully be taken as a basis.
NOTE   For the upgrading of accessibility of existing lifts in line with the recommendation of the European Commission dated 8th of June, 1995 (95/216/EC) concerning improvements to safety of existing lifts, see EN 81-82.

  • Standard
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of this European Standard specifies the additional materials, manufacturing and testing requirements for stranded ropes for suspension, compensating and governor duties for traction drive and hydraulic lifts moving between guides to those given in part 1.
It shall be used in conjunction with parts 1 and 2 of this standard.
This Part of this European Standard does not establish requirements for information for use other than those given in clause 7 of part 1. Neither does it cover the requirements for ropes fitted with terminations.
Minimum breaking force values for the more common classes, sizes and grades of ropes are provided in
Tables 5 to 9.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document gives additional and deviating requirements to EN 81-1 and EN 81-2 as applicable in order to ensure the safety of lift users and the availability of lifts, which may be used for vandal resistant purposes. In all other respects such lifts are designed in accordance with EN 81-1, including Amendment A2 or EN 81-2, including Amendment A2. This document deals with the significant hazards, hazardous situations and events relevant to lifts which can be affected by vandalism (as listed in Clause 4) when they are used under the conditions as foreseen by the installer.
It does not cover building security or Category O lifts (see definition 3.2).

  • Standard
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the special provisions and safety rules to ensure the behaviour of lifts in the event of fire in a building, on the basis of a fire signal(s) to the lift(s) control system.
This standard applies to all new passenger lifts and goods passenger lifts with all types of drives. However, it may be used as a basis to improve the safety of existing passenger and goods passenger lifts.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

EN 81-50  specifies the design rules, calculations, examinations and tests of lift components which are referred to by other standards used for the design of passenger lifts, goods passenger lifts, goods only lifts, and other similar types of lifting appliances.

  • Standard
    94 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies the safety rules for permanently installed new passenger or goods passenger lifts, with traction, positive or hydraulic drive, serving defined landing levels, having a car designed for the transportation of persons or persons and goods, suspended by ropes, chains or jacks and moving between guide rails inclined not more than 15° to the vertical. In addition to the requirements of this standard, supplementary requirements shall be considered in special cases (use of lifts by persons with disabilities, in case of fire, potentially explosive atmosphere, extreme climate conditions, seismic conditions, transporting dangerous goods, etc.).

  • Standard
    163 pages
    English language
    sale 10% off
    e-Library read for
    1 day

1.1   This standard specifies the safety rules for permanently installed new passenger or goods passenger lifts, with traction, positive or hydraulic drive, serving defined landing levels, having a car designed for the transportation of persons or persons and goods, suspended by ropes, chains or jacks and moving between guide rails inclined not more than 15° to the vertical.
1.2   In addition to the requirements of this standard, supplementary requirements shall be considered in special cases (use of lifts by persons with disabilities, in case of fire, potentially explosive atmosphere, extreme climate conditions, seismic conditions, transporting dangerous goods, etc.).
1.3   This standard does not cover:
a)   lifts with:
1)   drive systems other than those stated in 1.1;
2)   rated speed ≤ 0,15 m/s;
b)   hydraulic lifts:
1)   with a rated speed exceeding 1 m/s;
2)   where the setting of the pressure relief valve (5.9.3.5.3) exceeds 50 MPa;
c)   new passenger or goods passenger lifts in existing buildings  ) where in some circumstances due to limitations enforced by building constraints, some requirements of EN 81-20 cannot be met and EN 81-21 should be considered;
d)   lifting appliances, such as paternosters, mine lifts, theatrical lifts, appliances with automatic caging, skips, lifts and hoists for building and public works sites, ships' hoists, platforms for exploration or drilling at sea, construction and maintenance appliances or lifts in wind turbines;
e)   important modifications (see Annex C) to a lift installed before this standard is brought into application;
f)   safety during operations of transport, erection, repairs, and dismantling of lifts.
However, this standard may usefully be taken as a basis.
Noise and vibrations are not dealt with in this standard as they are not found at levels which could be considered as harmful with regard to the safe use and maintenance of the lift (see also 0.4.2).
1.4   This standard is not applicable to passenger and goods passenger lifts, which are installed before the date of its publication.

  • Standard
    163 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard specifies the design rules, calculations, examinations and tests of lift components which are referred to by other standards used for the design of passenger lifts, goods passenger lifts, goods only lifts, and other similar types of lifting appliances.

  • Standard
    94 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This draft European Standard applies to alarm systems for all types of passenger and goods passenger lifts, in particular those covered in the EN 81 series.
This draft European Standard also deals with the minimum information given to the owner of the installation related to maintenance and rescue service.
This draft European Standard deals with the following significant hazard relevant to lifts when they are used as intended and under the conditions foreseen by the installer/manufacturer:
-   entrapment of users due to the lift not working properly.
This draft European Standard is not applicable to alarm systems intended to be used to call for help in other cases, e.g. heart attack, seeking information.
This draft European Standard is applicable to alarm systems used for lifts manufactured and installed after the date of publication by CEN of this standard. However, this draft European Standard may be taken into account when applied to existing lifts.
EN 81-70 gives additional requirements for persons with disabilities (e.g. inductive loop, alarm button).

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document gives additional and deviating requirements to EN 81-20 as applicable in order to ensure the safety of lift users and the availability of lifts, which may be used for vandal resistant purposes. In all other respects such lifts are designed in accordance with EN 81-20. This document deals with the significant hazards, hazardous situations and events relevant to lifts which can be affected by vandalism (as listed in Clause 4) when they are used under the conditions as foreseen by the installer.
It does not cover building security or Category 0 lifts (see definition 3.2).
For other types of lifts, e.g. inclined lifts according to EN 81-22, this standard can usefully be taken as a basis.

  • Standard
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the special provisions and safety rules for passenger and goods passenger lifts where these lifts are permanently installed in buildings that are in compliance with EN 1998-1(Eurocode 8). This standard defines additional requirements to EN 81-1 and EN 81-2. It applies to new passenger lifts and goods passenger lifts. However, it may be used as a basis to improve the safety of existing passenger and goods passenger lifts. It does not apply to seismic lift category 0 as defined in Table A.1. This European Standard does not address other risks due to seismic events (for example fire, flood, explosion).

  • Standard
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard applies to alarm systems for all types of passenger and goods passenger lifts, in particular those covered in the EN 81 series.
This European Standard also deals with the minimum information to be provided as part of the instruction manual related to maintenance and the rescue service.
This European Standard deals with the following significant hazard relevant to lifts when they are used as intended and under the conditions foreseen by the installer/manufacturer:
-   entrapment of users due to the lift not working properly.
This European Standard is not applicable to alarm systems intended to be used to call for help in other cases, e.g. heart attack, seeking information.
This European Standard is applicable to alarm systems used for lifts manufactured and installed after the date of publication by CEN of this standard. However, this European Standard can be taken into account when applied to existing lifts.
EN 81 70 gives additional requirements for persons with disabilities (e.g. inductive loop, alarm button).

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document gives additional and deviating requirements to EN 81-20 as applicable in order to ensure the safety of lift users and the availability of lifts, which may be used for vandal resistant purposes. In all other respects such lifts are designed in accordance with EN 81-20. This document deals with the significant hazards, hazardous situations and events relevant to lifts which can be affected by vandalism (as listed in Clause 4) when they are used under the conditions as foreseen by the installer.
It does not cover building security or Category 0 lifts (see definition 3.2).
For other types of lifts, e.g. inclined lifts according to EN 81-22, this standard can usefully be taken as a basis.

  • Standard
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the special provisions and safety rules for passenger and goods passenger lifts where these lifts are permanently installed in buildings that are in compliance with EN 1998-1 (Eurocode 8).
This standard defines additional requirements to EN 81 1 and EN 81 2.
It applies to new passenger lifts and goods passenger lifts. However, it may be used as a basis to improve the safety of existing passenger and goods passenger lifts.
It does not apply to seismic lift category 0 as defined in Table A.1.
This European Standard does not address other risks due to seismic events (for example fire, flood, explosion).

  • Standard
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European standard applies to all types of passenger and passenger goods lifts, in particular those covered by the series of EN 81 standards, and may be applied to similar equipment where there is a risk of trapping users. This European standard defines the basic characteristics of an emergency alarm system required within a lift provided for the safety of all users.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the method of test for determining the fire resistance of lift landing doors which may be exposed to a fire from the landing side. The procedure applies to all types of lift landing doors used as a means of access to lifts in buildings and which are intended to provide a fire barrier to the spread of fire via the lift well. The procedure allows for the measurement of integrity and if required the measurement of radiation and thermal insulation. No requirements are included for mechanical conditioning as these are included in the relevant product standard.

  • Standard
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the minimum requirements for the safe and independent access and use of lifts by a wide range of persons, including persons with disabilities.
It is applicable to new passenger and goods passenger lifts according to EN 81-20. For other types of lifts, e.g. inclined lifts according to EN 81 22, this standard can usefully be taken as a basis.
NOTE 1   For guidance on solutions for increased accessibility and usability see Annex D.
NOTE 2   For the upgrading of accessibility of existing lifts in line with the recommendation of the European Commission dated 8th of June, 1995 (95/216/EC) concerning improvements to safety of existing lifts, see EN 81-82.

  • Standard
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European standard specifies the requirements for the accessibility of new lifts serving defined landing levels, having a car designed for the transportation of persons, and moving along guide rails inclined at an angle of more then 15degrees to the horizontal. NOTE: This standard may be used as guidance for upgrading existing lifts in line with the recommandation of the European Commission dated 8th of June, 1995 (95/216/EC) concerning improvements to safety of existing lifts. This European standard describes three sizes of lifts offering different levels of accessibility to wheelchair users.

  • Standard
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document gives additional and deviating requirements to EN 81-1 and EN 81-2 as applicable in order to ensure the safety of lift users and the availability of lifts, which may be used for vandal resistant purposes. In all other respects such lifts are designed in accordance with EN 81-1, including Amendment A2 or EN 81-2, including Amendment A2. This document deals with the significant hazards, hazardous situations and events relevant to lifts which can be affected by vandalism (as listed in Clause 4) when they are used under the conditions as foreseen by the installer.
It does not cover building security or Category O lifts (see definition 3.2).

  • Standard
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    27 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European standard applies to all types of passenger and passenger goods lifts, in particular those covered by the series of EN 81 standards, and may be applied to similar equipment where there is a risk of trapping users. This European standard defines the basic characteristics of an emergency alarm system required within a lift provided for the safety of all users.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the method of test for determining the fire resistance of lift landing doors which may be exposed to a fire from the landing side. The procedure applies to all types of lift landing doors used as a means of access to lifts in buildings and which are intended to provide a fire barrier to the spread of fire via the lift well. The procedure allows for the measurement of integrity and if required the measurement of radiation and thermal insulation. No requirements are included for mechanical conditioning as these are included in the relevant product standard.

  • Standard
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the special provisions and safety rules to ensure the behaviour of lifts in the event of fire in a building, on the basis of a signal(s) from the fire alarm detection system to the lift(s) control system.
It applies to new passenger lifts and goods passenger lifts. However, it may be used as a basis to improve the safety of existing passenger and goods passenger lifts.
This standard gives various options for control of the lift in the event of a fire in a building.
This standard does not apply to:
3   lifts which remain in use in the event of fire e.g. firefighters' lifts as defined in EN 81-72:2003;
3   the use of lifts for the evacuation of a building and
3   a fire in the well.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the special provisions and safety rules describing the behaviour of lifts in the event of fire in a building, on the basis of a recall signal(s) to the lift(s) control system.
This European Standard applies to new passenger lifts and goods passenger lifts with all types of drives. However, it may be used as a basis to improve the safety of existing passenger and goods passenger lifts.
This European Standard does not apply to
-   lifts that remain in use in the event of fire e.g. firefighters lifts as defined in EN 81 72,
-   lifts used for the evacuation of a building.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day