This document is applicable to instruments measuring radiant power emitted from sources that
are typical for the fibre-optic communications industry. These sources include laser diodes,
light emitting diodes (LEDs) and fibre-type sources. Both divergent and collimated radiations
are covered. This document defines the calibration of power meters to be performed by
calibration laboratories or by power meter manufacturers.

  • Standard
    46 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61315:2019 is available as IEC 61315:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61315:2019 is applicable to instruments measuring radiant power emitted from sources that are typical for the fibre-optic communications industry. These sources include laser diodes, light emitting diodes (LEDs) and fibre-type sources. Both divergent and collimated radiations are covered. This document defines the calibration of power meters to be performed by calibration laboratories or by power meter manufacturers. This third edition cancels and replaces the second edition published in 2005. It constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) update of terms and definitions; b) update of 5.1, including Table 1 (new type of source); c) update of Annex A; d) addition of Annex B on dB conversion. Keywords: Fibre-optic power meters

  • Standard
    46 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61315:2019 is available as IEC 61315:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61315:2019 is applicable to instruments measuring radiant power emitted from sources that are typical for the fibre-optic communications industry. These sources include laser diodes, light emitting diodes (LEDs) and fibre-type sources. Both divergent and collimated radiations are covered. This document defines the calibration of power meters to be performed by calibration laboratories or by power meter manufacturers. This third edition cancels and replaces the second edition published in 2005. It constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) update of terms and definitions;
b) update of 5.1, including Table 1 (new type of source);
c) update of Annex A;
d) addition of Annex B on dB conversion.
Keywords: Fibre-optic power meters

  • Standard
    87 pages
    English and French language
    sale 15% off

IEC 62129-1:2016 specifies procedures for calibrating an optical spectrum analyzer that is developed for use in fibre-optic communications and designed to measure the power distribution of an optical spectrum. It does not apply to an optical wavelength meter that measures only centre wavelengths, a Fabry-Perot interferometer or a monochromator that has no display unit. This first edition of IEC 62129-1 cancels and replaces the first edition of IEC 62129, published in 2006. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - update of term and definitions; - update of calibration conditions; - calculation change of uncertainties related to wavelength temperature dependence, power linearity, power level temperature dependence; - move of Annex E to the bibliography. Keywords: calibrating an optical spectrum analyser

  • Standard
    57 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62129-1:2016 specifies procedures for calibrating an optical spectrum analyzer that is developed for use in fibre-optic communications and designed to measure the power distribution of an optical spectrum. It does not apply to an optical wavelength meter that measures only centre wavelengths, a Fabry-Perot interferometer or a monochromator that has no display unit. This first edition of IEC 62129-1 cancels and replaces the first edition of IEC 62129, published in 2006. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- update of term and definitions;
- update of calibration conditions;
- calculation change of uncertainties related to wavelength temperature dependence, power linearity, power level temperature dependence;
- move of Annex E to the bibliography.
Keywords: calibrating an optical spectrum analyser

  • Standard
    110 pages
    English and French language
    sale 15% off

This international standard is applicable to instruments measuring radiant power emitted from sources which are typical for the fibre-optic communications industry. The standard describes the calibration of power meters to be performed by calibration laboratories or by power meter manufacturers.

  • Standard
    45 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This standard provides standard procedures for the calibration of  optical fibre chromatic dispersion (CD) test sets. It also  provides procedures to perform calibration checking on CD test  sets whereby an extension to the test set calibration period  may be obtained. This standard is applicable to all types of CD  test set, with the exception that measurements on multimode  optical fibers are excluded.

  • Standard
    57 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Superseded by EN 61316:2006

  • Standard
    64 pages
    English language
    sale 10% off
    e-Library read for
    1 day

EN following parallel vote * Superseded by EN 61744:2005

  • Standard
    48 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This international standard is applicable to instruments measuring radiant power emitted from sources which are typical for the fibre-optic communications industry. The standard describes the calibration of power meters to be performed by calibration laboratories or by power meter manufacturers.

  • Standard
    45 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Fibre optic power meters are designed to measure optical power from fibre optic sources as accurately as possible. This capability depends largely on the quality of the calibration process. This International Standard standardizes all of the steps involved in the calibration process: establishing the reference conditions, carrying out the calibration, calculating the uncertainty, and reporting the uncertainty, the reference conditions, and the traceability. It also creates a standardized type of power meter specification, which will make it easier to compare power meters from different vendors.

  • Standard
    64 pages
    English language
    sale 10% off
    e-Library read for
    1 day