33.140 - Special measuring equipment for use in telecommunications
ICS 33.140 Details
Special measuring equipment for use in telecommunications
Besondere Me?instrumente fur Telekommunikation
Materiel de mesure specifique aux telecommunications
Posebna merilna oprema za uporabo v telekomunikacijah
General Information
This document is applicable to instruments measuring radiant power emitted from sources that
are typical for the fibre-optic communications industry. These sources include laser diodes,
light emitting diodes (LEDs) and fibre-type sources. Both divergent and collimated radiations
are covered. This document defines the calibration of power meters to be performed by
calibration laboratories or by power meter manufacturers.
- Standard46 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61315:2019 is available as IEC 61315:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61315:2019 is applicable to instruments measuring radiant power emitted from sources that are typical for the fibre-optic communications industry. These sources include laser diodes, light emitting diodes (LEDs) and fibre-type sources. Both divergent and collimated radiations are covered. This document defines the calibration of power meters to be performed by calibration laboratories or by power meter manufacturers. This third edition cancels and replaces the second edition published in 2005. It constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) update of terms and definitions; b) update of 5.1, including Table 1 (new type of source); c) update of Annex A; d) addition of Annex B on dB conversion. Keywords: Fibre-optic power meters
- Standard46 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 61315:2019 is available as IEC 61315:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61315:2019 is applicable to instruments measuring radiant power emitted from sources that are typical for the fibre-optic communications industry. These sources include laser diodes, light emitting diodes (LEDs) and fibre-type sources. Both divergent and collimated radiations are covered. This document defines the calibration of power meters to be performed by calibration laboratories or by power meter manufacturers. This third edition cancels and replaces the second edition published in 2005. It constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) update of terms and definitions;
b) update of 5.1, including Table 1 (new type of source);
c) update of Annex A;
d) addition of Annex B on dB conversion.
Keywords: Fibre-optic power meters
- Standard87 pagesEnglish and French languagesale 15% off
IEC 62129-1:2016 specifies procedures for calibrating an optical spectrum analyzer that is developed for use in fibre-optic communications and designed to measure the power distribution of an optical spectrum. It does not apply to an optical wavelength meter that measures only centre wavelengths, a Fabry-Perot interferometer or a monochromator that has no display unit. This first edition of IEC 62129-1 cancels and replaces the first edition of IEC 62129, published in 2006. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - update of term and definitions; - update of calibration conditions; - calculation change of uncertainties related to wavelength temperature dependence, power linearity, power level temperature dependence; - move of Annex E to the bibliography. Keywords: calibrating an optical spectrum analyser
- Standard57 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62129-1:2016 specifies procedures for calibrating an optical spectrum analyzer that is developed for use in fibre-optic communications and designed to measure the power distribution of an optical spectrum. It does not apply to an optical wavelength meter that measures only centre wavelengths, a Fabry-Perot interferometer or a monochromator that has no display unit. This first edition of IEC 62129-1 cancels and replaces the first edition of IEC 62129, published in 2006. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- update of term and definitions;
- update of calibration conditions;
- calculation change of uncertainties related to wavelength temperature dependence, power linearity, power level temperature dependence;
- move of Annex E to the bibliography.
Keywords: calibrating an optical spectrum analyser
- Standard110 pagesEnglish and French languagesale 15% off
This international standard is applicable to instruments measuring radiant power emitted from sources which are typical for the fibre-optic communications industry. The standard describes the calibration of power meters to be performed by calibration laboratories or by power meter manufacturers.
- Standard45 pagesEnglish languagesale 10% offe-Library read for1 day
This standard provides standard procedures for the calibration of optical fibre chromatic dispersion (CD) test sets. It also provides procedures to perform calibration checking on CD test sets whereby an extension to the test set calibration period may be obtained. This standard is applicable to all types of CD test set, with the exception that measurements on multimode optical fibers are excluded.
- Standard57 pagesEnglish languagesale 10% offe-Library read for1 day
- Draft35 pagesEnglish languagesale 10% offe-Library read for1 day
Superseded by EN 61316:2006
- Standard64 pagesEnglish languagesale 10% offe-Library read for1 day
EN following parallel vote * Superseded by EN 61744:2005
- Standard48 pagesEnglish languagesale 10% offe-Library read for1 day
This international standard is applicable to instruments measuring radiant power emitted from sources which are typical for the fibre-optic communications industry. The standard describes the calibration of power meters to be performed by calibration laboratories or by power meter manufacturers.
- Standard45 pagesEnglish languagesale 10% offe-Library read for1 day
Fibre optic power meters are designed to measure optical power from fibre optic sources as accurately as possible. This capability depends largely on the quality of the calibration process. This International Standard standardizes all of the steps involved in the calibration process: establishing the reference conditions, carrying out the calibration, calculating the uncertainty, and reporting the uncertainty, the reference conditions, and the traceability. It also creates a standardized type of power meter specification, which will make it easier to compare power meters from different vendors.
- Standard64 pagesEnglish languagesale 10% offe-Library read for1 day